Ventilating grilles, Ventilating valves

Size: px
Start display at page:

Download "Ventilating grilles, Ventilating valves"

Transcription

1 01 Ventilating grilles Grilles with thermostatic regulation Special grilles Ventilating valves Staircase swirl diffusers

2 SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING GRILLES, VENTILATING VALVES Ventilating grilles, Ventilating valves Ventilating grilles are designed for all types of low-pressureair-conditioning-, heating- and ventilation systems with built in air flow- and throw distance control as well as regulation of discharge angle. They can be used for both, supply air and exhaust air applications. Ventilating valves are designed to extract air from sanitary rooms and other premises and can be also used in low pressure air-conditioning systems with air flow control. AIR DISPLACEMENT UNITS SUPPLY AIR NOZZLES SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES EXTERNAL ELEMENTS AIR FLOW CONTROL UNITS

3 Overview Steel ventilating grilles, stainless steel grilles JR- JR- JR-7 JR-8 RR-1 RR- RR- RR-6 JRU- JRU-6 Duct grilles for circular and rectangular ducts Grilles with thermostatic regulation (steel) SK-2 SK- SK- SK-9 JR-8/TR Ceiling grilles Special grilles (Grease traps, Filter grilles, Linear grilles) SR-1 SR-2 SR- SR- LM-1 LM-2 /PF /T Ventilating valves and staircase swirl diffusers PV-1N PV-2N PV- STD-1 STD-2 6

4 Content SUPPLY AIR NOZZLES AIR DISPLACEMENT UNITS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS Legend of symbols AI Element is made of aluminium profiles, aluminium sheet or aluminium casting. Element is intended to be built in the wall. Element is suitable for the supply of cool air (cooling). EXTERNAL ELEMENTS St RAL 90 Element is made of steel sheet. Element is powder painted in standard RAL 90 colour. Other desired colour is to be specified in the order. Element is intended to be built in the ceiling or in the wall. Element for air conditioning of rooms with floor to ceiling heights room up to m. M F EU... Element allows regulation by electric motor (Belimo electric motors). Element is intended for air filtration. The filter of class is built in. AIR FLOW CONTROL UNITS Shady symbol means possibility of optional material, surface protection, motor version, Element is intended to be built in the floor. Element for air conditioning of rooms with floor to ceiling heights from 6 to 1 m. Element is suitable for the supply of warm air (heating). CD INOX The possibility of the automatic selection and calculation of the technical characteristics of grilles and difusers in regard to the given conditions with the assistance of the Klima ADE program. The element is made of stainless sheet steel AISI 0. SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES 7

5 Ventilating grilles Steel grilles Visible or hidden screw installation Steel sheet powder painted in standard RAL 90 colour JR-, JRP- Individually adjustable horizontal blades JRP-: galvanised steel sheet RAL 90 H/B CD St JR-, JRP- Individually adjustable vertical blades JRP-: galvanised steel sheet RAL 90 H/B CD St JR-7, JRP-7 Individually adjustable horizontal and vertical blades 6 JRP-7: galvanised steel sheet RAL 90 H/B CD St JR-8, JRP-8 Individually adjustable horizontal and vertical blades 6 JRP-8: galvanised steel sheet RAL 90 H/B CD St Ordering key JR-1/2-F B x H F Registers F, S, T V Visible screw installation 2 Hidden screw installation V2 Visible screw installation + installation frame Spring 1 Grille type JR-, JR-, JR-7, JR-8 JR Steel grille JRP Galvanised steel grille 12

6 Ventilating grilles Stainless steel grilles RR-1, RR-, RR-, RR-6 Visible or hidden screw installation Flat framer Stainless steel AISI 0 (BA polished, high gloss) RR-1 Individually adjustable vertical and horizontal blades RR- Fixed horizontal blades RR- Individually adjustable horizontal blades RR-6 Individually adjustable vertical blades INOX H/B H/B H/B H/B H/B H/B 6 VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPLACEMENT UNITS SUPPLY AIR NOZZLES EXTERNAL ELEMENTS Ordering key RR-1/V F F Register classic FI Register INOX (frame INOX, aluminium blades) C Register INOX (for RR- only) C1 Register INOX (for RR-6 only) V Visible screw installation screw INOX 2 Installation frame and locks galvanised (for RR-1,, 6 only) 2I Installation frame INOX and galvanised locks (for RR-1,, 6 only) V2 Visible screw installation + installation frame galvanised V2I Visible screw installation + installation frame INOX grille type RR-1, RR-, RR-, RR-6 AIR FLOW CONTROL UNITS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES 1

7 Ventilating grilles Grille standard dimensions and cross-sections (m²) for JR-, JR-, RR-, RR-6: B/H B/H Grille standard dimensions and cross-sections (m²) for JR-7, JR-8, RR-1: B/H B/H Standard dimensions for RR-: B/H

8 Ventilating grilles Curved steel grilles Application Ventilating curved grilles are designed for all types of low-pressure- air-conditioning, heating and ventilation systems with built in air flow and throw distance control. JRU- 6 also has built-in regulation of discharge angle. They can be used for both, supply air and exhaust air applications. Description Steel curved grilles are made of sheet steel and powder-coated in RAL 90. Upon customers request they can be made of galvanised or stainless steel or painted in any other RAL colour. Both types are available in concave or convex version. Standard dimensions St RAL H/B B R VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS B/H SLOT DIFFUSERS, ROUND DUCT DIFFUSERS R AIR DISPLACEMENT UNITS JRU- Individually adjustable horizontal curved blades Frame (curve R) Visible screw installation JRU B H R min (mm) H/B B SUPPLY AIR NOZZLES JRU-6 Individually adjustable vertical curved blades Frame (curve R) Visible screw installation EXTERNAL ELEMENTS JRU 6 B H R min (mm) Ordering key AIR FLOW CONTROL UNITS JRU /V/KK B x H x R KK Convex KO Concave Visible screw installation Grille type SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES 1

9 Ventilating grilles Steel duct grilles SK-2, SK-, SK-, SK-9 For circular ducts Visible screw installation SKP-2, SKP-, SKP-, SKP-9: galvanised steel type St RAL 90 CD SK-2 Individually adjustable horizontal and vertical blades H-1/B-1 H1/B1 H-1/B-1 H1/B1 H-1/B-1 H1/B1 H-1/B-1 H1/B1 SK- Individually adjustable vertical blades SK- Individually adjustable horizontal blades SK-9 Individually adjustable horizontal and vertical blades 16

10 Ventilating grilles Standard dimensions B/H a H H1/B1 H-1/B-1 D B1 = B-27 H1 = H-27 VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS Dimensions H H a diameter D SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS Ordering key SK-2 / V-F B x H F Registers (see page 27) V Visible screw installation Grille type SLOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPLACEMENT UNITS SK Steel grilles SKP Galvanised steel grilles SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES AIR FLOW CONTROL UNITS SUPPLY AIR NOZZLES EXTERNAL ELEMENTS 17

11 Ventilating grilles Steel ceiling grilles SR-1, SR-2, SR-, SR- Fixed blades Visible screw installation Foamy sealing strip around the frame Ceiling installation St RAL 90 H/B H-16/B SR-1 One-way air supply 1 H1 B1 SR-2 Two-way air supply 2 H1 2 B1 SR- Three-way air supply H1 B1 SR- Four-way air supply H1 B1 18

12 Ventilating grilles Standard dimensions B/H VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS Ordering key SR-1/V-F2 B x H F2 Registers (see page 27) V Visible screw installation V2 Visible screw installation+installation frame Grille type SR Steel grilles SRP Galvanised steel grilles SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES AIR FLOW CONTROL UNITS AIR DISPLACEMENT UNITS EXTERNAL ELEMENTS SUPPLY AIR NOZZLES 19

13 Ventilating grilles Ventilating grilles installation Wall installation with built-in frame and hidden fixing (lock) B1 = B-27 H1 = H-27 H1/B1 27 B2 = B-1 H2 = H-1 The list of grilles and their designation: RR-1/2, RR-/2, RR-/2 and RR-6/2 7 H2/B2 H/B Wall installation with built-in frame and visible fixing B1 = B-27 H1 = H-27 B2 = B-1 H2 = H-1 The list of grilles and their designation: RR-1/V2, RR-/V2, RR-/V2, RR-6/V2, SR-(1-)/V2 H1/B H2/B2 H/B Installation on wall or duct with screw-type installation frame and hidden fixing (lock) B1 = B-27 H1 = H-27 B2 = B-1 H2 = H-1 The list of grilles and their designation: RR-1/2, RR-/2, RR-/2 in RR-6/2 H1/B H2/B2 H/B Installation on wall or duct with screw-type installation frame and visible fixing B1 = B-27 H1 = H-27 B2 = B-1 H2 = H-1 The list of grilles and their designation: RR-1/V2, RR-/V2, RR-/V2, RR-6/V2, SR-(1-)/V2 H1/B H2/B2 H/B 22

14 Ventilating grilles Direct installation in wall or duct via the visible fixing B1 = B-27 H1 = H-27 The list of grilles and their designation: RR-1/V, RR-/V, RR-/V, RR-6/V H1/B VENTILATING GRILLES, VENTILATING VALVES H-/B- SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS Installation of SK-2,,,9 grilles directly in the round duct with visible screw-fixing The list of grilles and their designation: SK-2, SK-, SK-, SK-9 B-1 H-1 H-1/B-1 H1/B1 R SLOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPLACEMENT UNITS Mounting of grilles without installation frame Visible screw installation / V B1 = B-27 H1 = H-27 JR-, JR- h = mm JR-7, JR-8 h = 6 mm Marking: JR-/V, JR-/V, JR-7/V, JR-8/V Mounting of grilles with installation frame h H1/B1 H-/B- 27 SUPPLY AIR NOZZLES EXTERNAL ELEMENTS The installation frame may be mortar-mounted (in concrete or brick walls) or fixed with screws (walls, ceilings, ducts, ). AIR FLOW CONTROL UNITS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES 2

15 Ventilating grilles Hidden screw fixing / 2 (lock) B1 = B-27 H1 = H-27 JR-, JR- h = mm JR-7, JR-8 h = 6 mm Marking: JR-/2, JR-/2, JR-7/2, JR-8/2 h H1/B1 27 H/B Visible screw fixing + installation frame / V2 B1 = B-27 H1 = H-27 H1/B1 27 JR-, JR- h = mm JR-7, JR-8 h = 6 mm h Marking: JR-/V2, JR-/ V2, JR-7/V2, JR-8/V2 H/B Hidden fixing / (spring) Warning: only for wall installation B1 = B-27 H1 = H-27 JR-, JR- h = mm JR-7, JR-8 h = 6 mm Marking: JR-/, JR-/, JR-7/, JR-8/ H/B h 27 H1/B1 H/B 27 H1/B1 2

16 Ventilating grilles Registers When adjusting the system, desired operating conditions are obtained by the means of ventilation elements control. Registers are installed for additional air volume control, thus influencing air velocity and throw distance as well. All types of registers, except type of register F, are made of sheet steel and corrosion protected with dipcoat processing in blackwater soluble colour. Upon customer s request registers can be made of galvanised sheet steel and coloured in any colour. Typ of register F is made of plastics. VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS F Register has wide counter-directional blades which can be moved with screw-driver via the gear wheel. It is used to control the air flow volume.blades are made of plastics. S Register has fixed deflector and slider which opens and closes the slots. Due to inclined deflection, air volume damper S is particularly useful for longer grilles, because air flow is evenly distributed throughout the grille. T Register has fixed deflector and slider which opens and closes the slots. It isused to control and deflect the air flow from the duct. PP Perforated sheet steel ( %) is used to split the air jet. Unfavourable is increased noise max SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES AIR DISPLACEMENT UNITS SUPPLY AIR NOZZLES EXTERNAL ELEMENTS AIR FLOW CONTROL UNITS 2

17 Ventilating grilles Set-up of different registers Register F Register T 26

18 Ventilating grilles Ventilating grilles/registers combinations Perforated sheet steel Grille F F2 S T PP JR- JR- JR-7 JR-8 RR-1 o o RR- o RR- o o RR-6 o o SK-2 o o SK- o o SK- o o SK-9 o o SR-1 SR-2 SR- SR- o standard combination possible combination VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS EXTERNAL ELEMENTS SUPPLY AIR NOZZLES SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPLACEMENT UNITS ASR-1 ASR-2 ASR- ASR- SR- o o o SR-6 o o o SR-7 o o SR-8 o o AIR FLOW CONTROL UNITS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES 27

19 Technical data Technical data Effective discharge area A ef (m²) AR-6, 7 RR- RR-1 SK- SK-2 B H AR- AR- RR- AR-8, 9 SK- RR-6 ASK-2 ASK- ASK- SK Discharge or inlet air flow volume is determined via air velocity measuring at the effective area with horizontally positioned blades. Use the below formula to calculate air flow volume Q = V ef x A ef x 600 (m³/h) V ef (m/s) A ef (m²) Effective jet velocity Effective area 28

20 Technical data VENTILATING GRILLES, VENTILATING VALVES F F F F F B H SR-1 SR-2 SR- SR-, SR F F F F F B H SR- SR-6 SR-7,8 SR-7 SR CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPLACEMENT UNITS SUPPLY AIR NOZZLES EXTERNAL ELEMENTS Calculation of A ef SR-1 A ef = SR-2 A ef = 2 x SR- A ef =2x + SR- A ef =2x +2x SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES AIR FLOW CONTROL UNITS 29

21 Technical data Ventilating grilles JR-,, 7, 8; RR-1,,, 6; SK-2,,, 9 without ceiling effect (distance from ceiling 0.8 m) Chart for determining the size, induction and temperature of the air flow valid for B/H 12 fully opened blades Effective discharge air velocity v ef (m/s) Induction i Width B (mm) Height H (mm) Air flow Q (m /h) Temperature factor t t z L Air jet velocity v L (m/s) Throw distance L (m) 1. Air jet width b 0.2(m) Definition of Symbols Q 0.2 b v (m/s) L L t ( C) L v = 0.2 m/s 0.8m Q (m /h) t ( C) Z Q (m³/h) L (m) V ef (m/s) V L (m/s) Air flow Throw distance Effective discharge air velocity Max. air velocity at the throw distance L 0.2 L A Q Occupied zone L Δt z (K) Δt L (K) i b 0.2 (m) Temperature difference between supply and room air Temperature difference between air jet and room temperature Induction rate = total airstream volume flow / volume flow at diffuser discharge Width of air jet is measured at a distance from ceiling where air flow velocity 0.2 m/s 0

22 Technical data Ventilating grilles JR-,, 7, 8 without ceiling effect (distance from ceiling 0.8 m) Chart for determining the size, induction and temperature of the air flow valid for B/H 12 fully opened blades Effective discharge air velocity v ef (m/s) Induction i VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS Width B (mm) Height H (mm) Air flow Q (m /h) Temperature factor t L t z AIR DISPLACEMENT UNITS Air jet width b 0.2(m) Air jet velocity v L (m/s) Throw distance L (m) Throw distance L (m) SUPPLY AIR NOZZLES SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES EXTERNAL ELEMENTS AIR FLOW CONTROL UNITS 1

23 Technical data Ventilating grilles JR-,, 7, 8; RR-1,,, 6; SK-2,,, 9 without ceiling effect (distance from ceiling 0.8 m) Table with correcting factors for horizontal air jet deflection: β α Blade adjusting angle β 90 Air jet spread angle α 60 Air flow velocity V L V L diag. x 0.7 x 0. Temperature factor Δt L/Δt Z (Δt L/ Δt Z diag.) x 0.7 x 0. Induction i i diag. x 1. x 2.0 Air jet drop y y diag. x 1. x 2.0 Distance between grilles A 0.2 L 0. L Chart for determining air jet deflection: Effective outlet area A (m 2 ef ) v (m/s) ef A (m ) ef t ( C) z heating L (m) v (m/s) ef y 6 2 L cooling y y= x t z t z diag. Air jet drop/rise y/ t (m/ C) z Example Given: Air flow: Q = 60 m³/h, L = m Air flow velocity: VL = 0. m/s Temperature difference: Δt Z = C Solution: Use the chart, distance from ceiling 0.8 m and select the grille type AR-1 size B = 2, H = 12 Effective outlet air velocity V ef =. m/s Temperature factor Δt L/Δt Z = 0.06 Temperature difference Δt L = 0.06 x = 0.2 C Induction i = 2 Width of the air jet b 0.2 = 1.0 m Min. distance between grilles A = 2 m 2

24 Technical data Ventilating grilles JR-,, 7, 8; RR-1,,, 6 with ceiling effect (distance from ceiling 0. m) Chart for determining the size, induction and temperature of the air flow valid for B/H 12 fully opened blades Effective discharge air velocity v ef (m/s) Induction i VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS Width B (mm) Height H (mm) Air flow Q (m /h) Temperature factor t L tz SLOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPLACEMENT UNITS Air jet velocity v L (m/s) Air jet width b 0.2 (m) Throw distance L (m) Throw distance L (m) SUPPLY AIR NOZZLES EXTERNAL ELEMENTS Definition of symbols Q A 0.1 L Q b 0.2 Occupied zone v (m/s) L L t ( C) L v = 0.2 m/s L 0.m Q (m /h) t ( C) Z Q (m³/h) L (m) V ef (m/s) V L (m/s) Δt z (K) Δt L (K) i b 0.2 (m) Air flow Throw distance Effective discharge air velocity Max. air velocity at the throw distance L Temperature difference between supply and room air Temperature difference between air jet and room temperature Induction rate = total airstream volume flow / volume flow at diffuser discharge Width of air jet is measured at a distance from ceiling where air flow velocity 0.2 m/s AIR FLOW CONTROL UNITS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES

25 Technical data Ventilating grilles JR-,, 7, 8; RR-1,,, 6 with ceiling effect (distance from ceiling 0. m) Chart for determining the size, induction and temperature of the air flow valid for B/H 12 fully opened blades Effective discharge air velocity v ef (m/s) Induction i Width B (mm) Height H (mm) Air flow Q (m /h) Temperature factor t L t z Air jet velocity v L (m/s) Throw distance L (m) 1 1. Air jet width b 0.2(m) Throw distance L (m) 0.

26 Technical data Table with correcting factors for horizontal air jet deflection β α Blade adjusting angle β 90 Air jet spread angle α 60 Air flow velocity V L V L diag. x 0.7 x 0. Temperature factor Δt L/Δt Z (Δt L/ Δt Z diag.) x 0.7 x 0. Induction i i diag. x 1. x 2.0 Air jet drop y y diag. x 1. x 2.0 Distance between grilles A 0.2 L 0. L VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS Chart for determining air jet deflection 1 SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS 2. Example Given: Air flow: Q = 60 m³/h, L = m Air flow velocity: V L = 0. m/s Temperature difference: Δt Z = C SLOT DIFFUSERS, ROUND DUCT DIFFUSERS Max. temperature difference by cooling t z ( C) ef v (m/s) Solution: Use the chart, distance from ceiling 0. m and select the grille type JR- size B = 62, H = 12 Effective outlet air velocity V ef = 2.8 m/s Temperature factor Δt L/Δt Z = 0.1 Temperature difference Δt L = 0.1 x = 0.6 C Induction i = 1 Width of the air jet b 0.2 = 1.0 m Min. distance between grilles A = 1. m AIR DISPLACEMENT UNITS SUPPLY AIR NOZZLES 2 Effective outlet area A ef (m ) EXTERNAL ELEMENTS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES AIR FLOW CONTROL UNITS

27 Technical data Technical data for ventilating grilles Pressure drop and sound power level diagram for grilles JR-,, 7, 8, RR-1,,, 6 with volume control damper F Fully opened blades Opened 0 2% 0% 0% Pressure drop in duct pcel (Pa) N R WA L (db(a)) Effective air veloctiy v ef (m/s) Regulation set-up p cel Table of correction factors for acoustic data A ef (m²) Correction (db(a)) N R Definition of symbols A ef Δp cel (Pa) L WA (db(a)) N R Effective outlet area Pressure drop Sound power level Max. value acc. to ISO vef Room sound attenuation diagram The following data are necessary to calculate the volume Q : 1. Normal rooms Q = Q 2. Rooms with highly reflective walls Q = 0.Q. Rooms with absorption walls Q = 2Q Room attenuation (db(a)) Volume Q (m) Definition of symbols Q (m³) Calculated volume, depending on room reflectance Q (m³) Actual room volume Distance from ventilating element (m) 6

28 Technical data Technical data for extracting grilles Presure drop and sound power level for grilles JR-,, 7, 8 RR-1,,, 6 with volume control damper F Fully opened blades Pressure drop in duct pcel (Pa) N R WA L (db(a)) Effective air veloctiy v ef (m/s) Opened 2% 0% 0% Regulation set-up e Regulation set-up v ef Table of correction factors for acoustic data p cel A ef (m²) Correction (db(a)) N R Definition of symbols VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPLACEMENT UNITS SUPPLY AIR NOZZLES EXTERNAL ELEMENTS AIR FLOW CONTROL UNITS 6 Effective air veloctiy v ef (m/s) Δp cel (Pa) L WA (db(a)) N R Pressure drop Sound power level Max. value acc. to ISO SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES 7

29 Technical data Effective supply air velocity diagram Effective outlet area A ef (m/s) Example Effective intel air velocity vef (m/s) 7 6 Q = 00 m³/h A ef = 0.0 m³ (from the Effective area table) As follows from the diagram. V ef =. m/s Air flow volume Q (m/h) Room sound attenuation diagram The following data are necessary to calculate the volume Q : 1. Normal rooms Q = Q 2. Rooms with highly reflective walls Q = 0.Q. Rooms with absorption walls Q = 2Q Room attenuation (db(a)) Volume Q (m) Definition of symbols Q (m³) Calculated volume, depending on room reflectance Q (m³) Actual room volume Distance from ventilating element (m) 8

30 Technical data Steel ceiling grilles SR-1, SR-2, SR-, SR- Chart for determing of effective outlet area, temperature and air flow induction VENTILATING GRILLES, VENTILATING VALVES A ef (m2 ) Effective discharge air velocity v (m/s) 2 1. ef Induction i 1 CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS Air flow Q (m /h) 0. Temperature factor 0.2 t z t L SLOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPLACEMENT UNITS Air jet velocity v (m/s) L 1 Throw distance L (m) SUPPLY AIR NOZZLES 7 Throw distance L (m) EXTERNAL ELEMENTS E v L(m/s) t L( C) L=C+E C v L(m/s) t L( C) v L=0.2m/s L(m) Q(m /h) t Z ( C) Izračun Calculation delnih of količin partial zraka: air flows SR-1, SR- SR-2, SR-6 Q1 = Qcel Q 2 = Qcel SR- Q = Qcel x F Q = Qcel x F 2F + F 2F + F SR- SR-7 SR-8 2 Q = Qcel x F Q = Qcel x F 2(F + F) 2(F + F) Q = Qcel x F Q = Qcel x F 2(F + F) 2(F + F) Q = Qcel x F Q = Qcel x F 2(F + F) 2(F + F) Definition of symbols Q (m³/h) Q cel(m³/h) A ef (m²) For every discharge field F1 F Is to be divided among every discharge field For particular discharge field F1 F according to table of standard dimensions AIR FLOW CONTROL UNITS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES 1

31 Technical data The data in diagram is valid for ceiling grilles SR-1, SR-2 SR- F value only, SR- F, value only, where The data in square ceiling diffusers diagram are valid for: SR- F value only, SR- F value only, SR- F value only, where H 1 B 2.1 H 1 B 2.1 When using diagram for square diffusers, partial air flows Q and Q as well as partial areas for particular discharge fields F or. F are to be multiplied by. Use the area of xf or xf (for correspondent sizes 1-8). Definition of symbols Q (m³/h) L (m) V L (m/s) V h (m/s) Δt L ( C) Δt z ( C) i b 0.2 (m) Air flow Throw distance:l /= C + E Max. air velocity at the throw distance L Vertical velocity at distance h from ceiling by combining two counterdirectional air jets Temperature difference between air jet and room temperature Temperature difference between supply and room air Induction rate = total airstream volume flow / volume flow at diffuser discharge Width of air jet is measured at a distance from ceiling where air flow velocity 0.2 m/s Pressure drop diagram: Valid for F 2 in F volume control dampers. 0 2% Opened 0% 0% Vertical velocity diagram Max. temperature quotient Δt h/δt z is determined with the basic diagram for temperature quotient, where: Pressure drop pcel (Pa) 0 0 R N = WA L (db(a)) Regulation set-up Distance from ceiling h (m) p cel Air jet velocity 0.8(m/s) Effective discharge air velocity v ef (m/s) Vertical velocity v h (m/s) L L v L h Example v (m/s) h t h( C) Given: Ceiling grille SR-/F2 size B = 1271 mm, H = 76 mm, Q cel = 107 m³/h. Effective areas of discharge fields according to table of standard dimensions: F = m², F = m² Calculation of partial air flows: 107 x Q = 2 x = 700 m³/h 107 x Q = 2 x = 7 m³/h As follows from the ceiling grilles diagram: L = 7.1 m, v L = 0. m/s, v ef = 2.8 m/s As follows from the square diffusers diagram: size, Q = x7 = 28 m³/h, L = 1. m, v L = 0. m/s, v ef = 2.8 m/s 2

32 Grilles with thermostatic regulation Grilles with thermostatic regulation VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS Steel grille with thermostatic regulation JR-8/TR The grille is intended for air supply. The first row of vertical blades can be set freely while the second row of horizontal blades is set automatically and adapted to the temperature of the supplied air. As long as the air temperature does not reach C the blades are directed at above the horizontal position. In the range between C and 0 C the blades are set automatically according to the characteristic of the thermostatic element. When the air temperature reaches or exceeds 0 C the blades are directed at below the horizontal position. St RAL 90 Depiction of blade angles at different temperatures of supplied air T < C SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPLACEMENT UNITS Description JR-8/TR grille is made of steel sheet. Blades in the second row are made of aluminum anodized profile. The whole grill is powder painted in RAL 90 or in the colour requested by buyer. Diagram: blade angles depending on the temperature of supplied air T > 0 C T = -0 C SUPPLY AIR NOZZLES EXTERNAL ELEMENTS Blade angles ( ) Temperature ( C) AIR FLOW CONTROL UNITS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES

33 Grilles with thermostatic regulation Installation of grilles with screws on the frame h Visible screw installation / V B1 = B-27 H1 = H-27 JR-8/TR h = 6 mm Marking: JR-8/TR/V H-/B- H1/B1 27 Dimensions and clean cross sections in m²: B/H B1 B1+ H1 H1+ Ordering key JR-8 / TR / V S B x H S Register S V Visible screw installation TR Thermostat regulation JR-8 Grille type

34 Special grilles Special grilles VENTILATING GRILLES, VENTILATING VALVES Grease traps LM-1, LM-2 Application Grease traps are used to extract air from kitchens and rooms with a high level of greasy steam. A special grease filter reduces the soiling of air ducts and ventilators. Grease traps permit no air flow regulation. Housing with groove is made of sheet steel and coloured in black. Description Filter consists of frame and infill made of expanded sheet aluminium. Construction made of stainless steel is available on request. Filter is easy to dismantle and wash in hot lye or other wash solutions (detergents). LM-1 LM-1 grease trap is designed for wall mounting. Extracted grease accumulates in special groove. Installation a) Installation in solid wall via the built-in frame. Designation LM-1/2 28 St 27 H B1 27 Technical data Diagram shows the pressure drop at the cross section B1xH1. Recommended air velocity is between 1 m/s and 2 m/s. Diagram is valid for LM-1 and LM-2. A ef=000/(b1-28xh-12)x0 2(vm²) H/B H/B 0 Dimensions B B1 H H CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPLACEMENT UNITS SUPPLY AIR NOZZLES H1/B1 28 H-/B- b) Direct installation in sheet steel duct. Designation LM-1 Pressure drop pt (Pa) EXTERNAL ELEMENTS AIR FLOW CONTROL UNITS H1/B1 H-7/B- H/B 1 2 Effective discharge air velocity v ef (m/s) SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES

35 Special grilles LM-2 Grase trap LM-2 is designed for ceiling installation. Extracted grease accumulates in special tube. Installations a) Installation in solid wall via the built-in frame. Designation LM-2/2 St RAL 90 H/B H-1/B-1 27 B1 27 Dimensions H+70/B+70 b) Installation in sheet steel duct. Designation LM-2/2 H-/B- 27 H1 27 H/B B B1 H H H+70/B+70 H/B 8 Ordering example Grease trap: LM-1 / 2 Size: B = 2 H = 22 Pcs: 6 6

36 Special grilles Filter grilles /PF Application Grilles with pre-filter are designed for application in rooms with special demands (computer centres, libraries, archives). Description Filter housing is designed to fit all sizes of ventilating grilles. It consists of galvanized sheet steel. Air volume is controlled by the means of F or T type air volume damper. Filter class G2 to F. Filter builds up the initial pressure of 0Pa by the air flow volume of 00 m³/h and air velocity V ef = 1. m/s (at the grille). In the course of time, when filter gets dirty, pressure drop is increased. F EU... St RAL 90 JR-,,7,8 RR-1,,,6 VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS Filter replacement When replacing the filter, remove the grille and take out the filter infill. Replace used filter infill with new one of the same quality. Fasten the new infill in the housing and finally replace the grille. H- / B- H-1 / B-1 SLOT DIFFUSERS, ROUND DUCT DIFFUSERS Installation Filter housing can be built-in or screwed in the duct. Grill is mounted on the filter housing: Ordering example Ventilating grille: With pre-filter: JR-PF/G2/2 F Size: B = 82 H = 12 Filter quality: G2, G, G, F Pcs: 1 1. with screws on the frame 2. with locks (hidden installation) (JR) ( JR) PF/V PF/2 AIR DISPLACEMENT UNITS SUPPLY AIR NOZZLES SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES AIR FLOW CONTROL UNITS EXTERNAL ELEMENTS 7

37 Special grilles Linear grilles T Application When there is a demand to assembly grilles in longer linear lines, linear grilles should be used. St RAL 90 Description Line is divided into approx. equal elements of 1. m. The elements are connected with special partition bars. Band grilles types JR-,. AR-6, AR-7 AR-6, AR-7 B- / H- B1/ B1/ B1/ Installation type example Visible screw connection with screws in the frame designation: JR-T/V Hidden installation with built-in frame and locks designation: JR-T/2 AR-8, AR-9 Regulation The same registers as for basic grilles. See table on the page 27. (B+)/ (B+)/ (B+)/ B / H AR-1, AR-1, JR-, JR- B- / H- B1/ B1/ B1/ Connection JR- Connection JR- Ordering key JR-T/2-F B x H F Register 2 Hidden screw installation V Visible screw installation T Linear version 6 Grille type JR -, 8

38 Plenum box for grilles Plenum box for grilles Plenum boxes Plenum box is designed for connection of ventilation grilles to the ventilation network. The most important function of plenum box is to create an even field of over- or underpressure (outlet) all over the effective outlet area of the grille. The construction of plenum box enables visible as well as hidden installation. Plenum box is made of galvanised sheet steel. Top entry spigot V Side entry spigot S Sizes Size B and H are the standard grille dimensions. Height of the plenum box h as well as entry spigot diameter фd is to be stated in order. h 0 v s d d Plenum box for the grilles stated below JR-,, 7, 8, RR-1,,, 6 11 B/H 11 Installation: Hidden assembly Visible assembly Ordering key Plenum box 62 x 22 / S / 1 x ф d 18 / h = 270 h Plenum box height фd E ntry spigot diameter 1 Number of spigots 2 S Side entry spigot V Top entry spigot Grille size BxH 0

39 Plenum box for grilles Table of recommended dimensions for the S version B H h* d* x18 2 2x x x x x x x x18 2 2x x x x x x x x x x x x18 h* recommended dimensions d* recommended dimensions B H h* d* x18 2 2x x x x x x x x x x x x x x x x x x x x198 B H h* d* x x x x x x28 2 2x x x x x x x x x x298 VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPLACEMENT UNITS SUPPLY AIR NOZZLES EXTERNAL ELEMENTS AIR FLOW CONTROL UNITS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES 1

40 Ventilating valve Ventilating valve PV-1N Description Fixed diffusion ring Adjustable disc for valve opening and closing Installation in built-in frame Peripheral foamy sealing strip Exhaust application Material Made of sheet steel and coloured upon customer s request. Component parts 1. Housing 2. Valve disc. Subframe Installation Frame is suitable for all installation types (wall, ceiling-or duct installation). It is fastened with screws. Place the valve in the groove and rotate it. Foamy sealant between the subframe and valve has a function to guarantee a perfect seal and to hold the valve in its position. St RAL 90 φb 1 2 Air flow regulation Adjust the air volume flow by rotating the valve disc in plus or minus direction. - S + s (mm) S S Dimensions: Size ΦB Ordering example Ventilating valve: PV-1N Size: 0 Pcs: 0 2

41 Ventilating valve PV-1N, size PV-1N, size VENTILATING GRILLES, VENTILATING VALVES p t (Pa) 0 0 L d B (A ) W A p t (Pa) 0 0 L d B (A ) W A CIRCULAR DIFFUSERS, SQUARE DIFFUSERS Pressure drop Pressure drop SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS Air flow Q ( m/h) Air flow Q ( m/h) PV-1N, size PV-1N, size SLOT DIFFUSERS, ROUND DUCT DIFFUSERS 0 0 L d B (A ) W A L d B (A ) W A AIR DISPLACEMENT UNITS p t (Pa) Pressure drop p t (Pa) Pressure drop SUPPLY AIR NOZZLES Air flow Q ( m/h) Air flow Q ( m/h) PV-1N, size 0 Pressure drop p t (Pa) L d B (A ) Air flow Q ( m/h) W A Example Use the air flow volume Q (m³/h) and pressure drop over the valve ΔP t (Pa) to determine the valve set-up s (mm) using the positive or negative direction. Given data: Q = 70m³/h, ΔP t = 60Pa Sizing diagram at the value 0 gives the valve set-up s = 0 mm. Definition of symbols Q (m³/h) Δp t (Pa) L WA (db(a)) Air flow Pressure drop Sound power level EXTERNAL ELEMENTS AIR FLOW CONTROL UNITS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES

42 Ventilating valve PV-2N Description Fixed diffusion ring Adjustable disc for valve opening and closing Installation in built-in frame Peripheral foamy sealing strip Supply application St RAL φb Material Made of sheet steel and coloured upon customer s request. Component parts 1. Housing 2. Valve disc. Subframe Installation Frame is suitable for all installation types (wall, ceiling-or duct installation). It is fastened with screws. Place the valve in the groove and rotate it. Foamy sealant between the subframe and valve has a function to guarantee a perfect seal and to hold the valve in its position. Air flow regulation Adjust the air volume flow by rotating the valve disc in plus or minus direction. - S + s (mm) S S Dimensions: Size ΦB Ordering example Ventilating valve: PV-2N Size: 0 Pcs: 0

43 Ventilating valve PV-2N, size PV-2N, size VENTILATING GRILLES, VENTILATING VALVES Pressure drop p t (Pa) Pressure drop p t (Pa) Pressure drop p t (Pa) Air flow Q (m/h) Air flow Q (m/h) PV-2N, size Air flow Q (m/h) Air flow Q (m/h) PV-2N, size W A L d B (A ) Air flow Q ( m/h) L d B (A ) W A W A L d B (A ) p t (Pa) Pressure drop Pressure drop 0 0 PV-2N, size 160 p t (Pa) L d B (A ) Definition of symbols Q (m³/h) Δp t (Pa) L WA (db(a)) Air flow Pressure drop W A Sound power level L d B (A ) W A CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPLACEMENT UNITS SUPPLY AIR NOZZLES EXTERNAL ELEMENTS AIR FLOW CONTROL UNITS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES

44 Ventilating valve PV- Application These valves are designed for business and residential use.they are suitable for wall or ceiling mounting. Meticulous workmanship allows inconspicuous installation. B A Description Two variants: exhaust and supply Sizes: Φ0, Φ12 mm, Φ160 mm Easy installation Environment friendly C Material The ventilating valve is made of antistatic ABS plastics. Installation The valve may be wall- or ceiling-mounted. In the case of a supply valve, set the regulator to stage 1, 2 or, depending on the desired flow rate. A standard exhaust PV- valve is not fitted with a deflector. The valve housing can be fitted with the RP-M air flow rate regulator. Standard dimensions Φ0 Φ12 Φ160 A B C Valve tests were carried out on ceiling-mounted valves, set to stage 1. Definition of symbols Exhaust Q Φ 0 basic element Φ 0 + RP-M m³/h P (Pa) Lw (db(a)) P (Pa) Lw (db(a)) 1 0. < 0 27 < Q Φ 12 basic element Φ 12 + RP-M m³/h P (Pa) Lw (db(a)) P (Pa) Lw (db(a)) 60 < Supply Q Φ 0 basic element Φ 0 + RP-M m³/h P (Pa) Lw (db(a)) Throw P (Pa) Lw (db(a)) 1 0. < 2,2 0 7 <, ,1 0 1 Δp (Pa) L WA (db(a)) Pressure drop Sound power level Q Φ 12 basic element Φ 12 + RP-M m³/h P (Pa) Lw (db(a)) Throw P (Pa) Lw (db(a)) 60 <, , ,2 0 1 Q Φ 160 basic element m³/h P (Pa) Lw (db(a)) , , 6

45 Ventilating valve Accessories RP-M REGULATOR for mounting on the PV- housing Φ0 mm: 1 do 60 m³/h Φ12 mm: 1 do 1 m³/h Sold separately RP-M/K REGULATOR for duct mounting Φ0 mm: 1 do 60 m³/h Φ12 mm: 60 do 1 m³/h Φ160 mm: 1 do 2 m³/h Sold separately MOUNTING FRAME Φ0 mm: length 10 mm Φ12 mm: length 10 mm Φ160 mm: length 10 mm Sold separately RP-M/K Flow rate (m³/h) Φ / / / / / / Φ / / / Φ Φ / / Φ / Φ / RPM: Size D1 (mm) D2 (mm) L (mm) Size Flow rate (m³/h) Flow Sound power level Lw (db(a)) rate (m³/h) 0 Pa 0 Pa 10 Pa 0 Pa Ordering key PV- / RP-M Size 0, 12, 160 Ordering key RP-M/K Size 80, 0, 12, 160, 0, D1 RP-M Flow rate regulator for PV- housing mounting RP-M/K Flow rate regulator with a duct mounting bracket VO Mounting frame BM White marble LO Wood walnut LR Wood red pine PR Pastel yellow PZ Pastel green PM Pastel blue L PV- Flow rate regulator with a duct mounting bracket D2 VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPLACEMENT UNITS SUPPLY AIR NOZZLES EXTERNAL ELEMENTS AIR FLOW CONTROL UNITS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES 7

46 Staircase swirl diffuser Staircase swirl diffuser Staircase swirl diffuser STD-1 STD-1/KK STD-1/KR STD-1/RR Application Staircase swirl diffusers STD-1 are ideal for use in theatres, auditoria, concert halls, cinemas, etc. They can be installed vertically in steps or floors which do not carry foot traffic. STD-1/KK STD-1/KR STD-1/RR Description They are made of sheet steel and powder coated with RAL 90 or RAL 900. Installation Floor installation or installation into steps STD-1/ /V STD-1/.../V φ 12 STD-1/ /T STD-1/.../T Installation: Vgradnja Floor Vgradnja installation: v v tla: tla: Vgradnja Stair v v stopnice: installation: V h1 V h1 t t h1 h1 V h1 V h1 t t h1 h1 L L h1 h1 h h X X L L h1 h1 V V (m (m /h) /h) pretok na na difuzorju V V (l/s) (l/s) pretok na na difuzorju Ordering key h h (m) (m) višina višina vgradnje nad nad tlemi tlemi L L (m) STD-1 (m) / KK oddaljenost / V od od difuzorja (L=h+x) hh 1 (m) 1 (m) razdalja merilne točke točke od od tal tal VV h1 (m/s) h1 (m/s) povprečna hitrost Installation zraka zraka na na razdalji h1 h1 od od tal tal * t * t Z (K) Z (K) temperaturna V razlika Visible med installation med temperaturo dovodnega zraka zraka in in zraka zraka v v prostoru * t * t h1 (K) h1 (K) razlika med med povprečno T Installation temperaturo with cross bar na na višini višini h1 h1 in in temperaturo v v prostoru p p t (Pa) t (Pa) padec tlaka tlaka KK Square diffuser plate, square blade arr. LL WA (db(a) WA A-utežena zvočna moč KR Square moč diffuser plate, radial blade arr. LL WNC NC WNC NC nivo nivo zvočne moči moči LL L WNR L = = LL + RR + 2 Circular diffuser plate, radial blade arr. 2 WNR WNR WNR WNC WNC LL pa,l pa,l pnc nivo pnc nivo zvočnega STD-1tlaka Diffuser utežen type po po A A krivulji ali ali NC NC nivo nivo v v odvisnosti od od prostora LL pa L pa L pwa - pwa - 88 db db LL pnc L pnc L pwnc - pwnc - 88 db db 8 * * Temperatura v v prostoru merjena od od 11 do do m od od tal! tal! Ključ Ključzaza naročanje: STD-1 / KK / V

47 t t Ventilating grilles, Ventilating valves Staircase swirl diffuser p v Pa V (l/s) Definition of symbols V (m³/h) Volume flow per diffuser v (l/s) Volume flow per diffuser h (m) Installation height above floor L (m) Distance from diffuser h 1 (m) Height of measurement point above floor V h1 (m/s) Time average air velocity at height h1 above floor Δt z (K) Temperature difference between supply air and room air* Δt h1 (K) Difference between core temperature at height h1 above floor and room temperature Δp t (Pa) Total pressure drop L WA (db(a) A-weighted sound power level L WNC NC rating of sound pover level L WNR L WNR= L WNc + 2 L pa, L pnc A-weighting or NC rating respectively of room sound pressure level L pa L pwa 8 db L pnc L pwnc 8 db *The room temperature is measured at 1.0 m to 1. m above the floor. Pressure drop and sound power level diagram V (m/h ) STD-1/.../T STD-1/.../D h 1= m h 1= m h 1= m V h1 (m/s) WNC STD-1/RR STD-1/KR L V (l/s) WA m /h L in db (A ) STD-1/KK p v Pa V h1 (m/s) STD-1/RR STD-1/KR L WNC WA L in db (A) m /h STD-1/KK V (m/h ) Air velocity of the throw distances STD-1/KR,RR STD-1/KK L(m) L(m) L(m) t h1 / t Z Stair installation - horizontal flow STD-1/RR STD-1/KR STD-1/KK VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES AIR DISPLACEMENT UNITS SUPPLY AIR NOZZLES EXTERNAL ELEMENTS AIR FLOW CONTROL UNITS 9

48 Staircase swirl diffuser STD-1/KR,RR STD-1/KK Floor installation - vertical flow h = m h 1= m h 1= m V h1 (m/s) m /h m /h V h1 (m/s) t h1 / t Z STD-1/RR STD-1/KR STD-1/KK L(m) L(m) L(m) STD-1/KR,RR STD-1/KK Stair installation - horizontal flow h 1= m h 1= m h 1= m V h1 (m/s) m /h V h1 (m/s) m /h t h1 / t Z STD-1/RR STD-1/KR STD-1/KK L(m) L(m) L(m) 60

49 Staircase swirl diffuser Staircase swirl diffuser STD-2 Application Staircase swirl diffusers STD-2 are ideal for use in theatres, auditoria, concert halls, cinemas, etc. They can be installed vertically in steps or floors, which do not carry foot traffic. The permitted supply air temperature difference is ± 6K. Description STD-2 are made of galvanized sheet steel and powder coated in RAL 90. On customer s request they are available in any other RAL colour. a STD-2/2 φ9 b L n x b L- a φ φ 70 VENTILATING GRILLES, VENTILATING VALVES Stopnišč Uporaba Stopni{~ za prezra ugodje. koncertn Vgrajuje v tla, ven Dovoljen je ± 6K. CIRCULAR DIFFUSERS, SQUARE DIFFUSERS Opis: Stopni{~ pocinkan 90. P barvo po SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS Tip STD-2/ STD-1/KKDimensions STD-2 6 STD-1/KR STD-2/2 STD-2/ STD-1/RR Type L (mm) a (mm) n x b STD-2/ x 80 STD-2/ x 8 STD-2/ x 88 STD-2/ x 92 STD-2/ x 7 STD-2/ STD-2/ STD-2/ STD-2/6 STD-2 STD-2 STD-2 STD-2 STD-2 SLOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPLACEMENT UNITS Effective discharge area No. of elements A ef (m²) STD-1/.../V φ h1 STD-1/.../T STD-2/ Vgradnja Vgradnja v tla: 1 STD-2/6 h L -2 h1 h1 h Vgradnja v stopnico: L h1 h Nomenklatura: Installation: Vgradnja Floor Vgradnja installation: v tla: V /element (l/s) pretok na posameznem elementu V (l/s) pretok na difuzorju Vgradnja h Stair (m) v stopnice: installation: vi{ina vgradnje nad tlemi (min. 0 mm) V h1 L (m) oddaljenost V h1 od difuzorja (L=h+x) t h1 h 1 (m) razdalja t h1 merilne to~ke od tal V h1 (m/s) povpre~na hitrost zraka na razdalji h1 od tal L t Z (K) * temperaturna X razlika med temperaturo dovodnega zraka in zraka v prostoru t h1 (K) L razlika med povpre~no temperaturo na vi{ini h1 in temperaturo v prostoru * p t (Pa) padec tlaka L WA (db(a)) A-utežena zvo~na mo~ V (m /h) pretok na difuzorju L WNC NC nivo zvo~ne mo~i V (l/s) pretok na difuzorju Ordering key h (m) višina vgradnje nad tlemi L (m) oddaljenost od difuzorja (L=h+x) * Temperatura STD-2/2 v prostoru merjena od 1 do 1. m od tal! h 1 (m) razdalja merilne točke od tal V h1 (m/s) povprečna hitrost zraka na razdalji h1 od tal 2,,,, 6 No. of distributive elements t Z (K) * temperaturna razlika med temperaturo dovodnega zraka in zraka v prostoru t h1 (K) * razlika med povprečno temperaturo na višini h1 in temperaturo v prostoru p t (Pa) padec tlaka L WA (db(a) A-utežena zvočna moč L Vh1 th1 h1 61 SUPPLY AIR NOZZLES EXTERNAL ELEMENTS AIR FLOW CONTROL UNITS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES

Ventilating grilles, Ventilating valves

Ventilating grilles, Ventilating valves 01 Ventilating grilles Grilles with thermostatic regulation Special grilles Ventilating valves Staircase swirl diffusers SOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS CIRCUAR

More information

Swirl diffusers, Variable swirl diffusers

Swirl diffusers, Variable swirl diffusers 0 Variable swirl diffusers SLOT IFFUSERS, ROUN UCT IFFUSERS SWIRL IFFUSERS, VARIABLE SWIRL IFFUSERS CIRCULAR IFFUSERS, SQUARE IFFUSERS VENTILATING GRILLES, VENTILATING VALVES, Variable swirl diffusers

More information

Variable swirl diffusers

Variable swirl diffusers Swirl diffusers, Variable swirl diffuser OD- Application Diffuser is designed for air conditioning of rooms with floor to ceiling highs of to 0 m and high induction requirements. It is suitable for large

More information

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Swirl diffusers, Variable swirl diffusers Swirl diffusers IMP Klima, Variable swirl diffusers Swirl diffuser OD- Fixed grille For air supply or exhaust Recommended temperature difference between supplied and internal air in the room is between 0 to 0 K Low static

More information

Slot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14

Slot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14 , Round duct diffusers D-, D- Application D- and D- slot diffusers are designed for the supply of air in rooms with floor to ceiling heights of.5 to m for supplying either cold or warm air, in particular

More information

Ceiling Diffuser. Type ADLR with circular face. Type ADLR-Q with square face 2/16/EN/8

Ceiling Diffuser. Type ADLR with circular face. Type ADLR-Q with square face 2/16/EN/8 2/16/EN/8 Ceiling Diffuser Type ADLR with circular face Type ADLR-Q with square face TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn

More information

SWIRL DIFFUSERS SWIRL DIFFUSERS OD-8

SWIRL DIFFUSERS SWIRL DIFFUSERS OD-8 SWIRL IFFUSERS O- St RAL 900 Swirl diffuser O- Square or round front plate with radial deflector arrangement Plastic deflectors Possible volume control damper in spigot C SWIRL IFFUSERS O- K 00/ O- R 00/

More information

Swirl Diffuser. Type SDW T 2.2/1/B/1. recommended for room heights from approx m

Swirl Diffuser. Type SDW T 2.2/1/B/1. recommended for room heights from approx m T 2.2/1/B/1 Swirl Diffuser Type SDW recommended for room heights from approx. 2.60... 4.00 m TROX UK Ltd Caxton Way Thetford Norfolk IP24 3SQ Telephone +44(0) 1842 54545 Telefax +44(0) 1842 63051 e-mail

More information

Grille. Min. - max. dimensions

Grille. Min. - max. dimensions Min. - max. dimensions H L 0 00 75 00 Standard grilles are available with mm pitch within the above min. and max. sizes. Customized sizes available on request. Description is an adjustable single or double

More information

Nozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

Nozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible. Nozzles About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement diffusers VAV

More information

Circular duct grille

Circular duct grille Dimensions B+0 A+0 A B Description is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air. The

More information

Krantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09.

Krantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09. Krantz Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 86 E 09./1 with square and circular blade array Preliminary remark The radial slot outlet

More information

Circular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct.

Circular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct. Dimensions B+0 A+0 A B Description RGS is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air.

More information

GTH. Rectangular double deflection grille QUICK FACTS

GTH. Rectangular double deflection grille QUICK FACTS Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Available in alternative colours A

More information

Krantz. RL-C2 radial slot outlet. Air distribution systems

Krantz. RL-C2 radial slot outlet. Air distribution systems RL-C2 radial slot outlet Air distribution systems DS E 04.1 Introduction The RL-C2 radial slot outlet with circular face generates a turbulent mixed flow. It is used for supply and return air distribution

More information

Slot diffuser. Type VSD35 2/2.6/B/3. with 35 mm wide slot

Slot diffuser. Type VSD35 2/2.6/B/3. with 35 mm wide slot 2/2.6/B/3 Slot diffuser Type VSD35 with 35 mm wide slot TROX UK Ltd Telephone +44 (0) 1842 754545 Caxton Way Telefax +44 (0) 1842 763051 Thetford e-mail trox@troxuk.co.uk Norfolk IP24 3SQ www.troxuk.co.uk

More information

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS Circular ceiling diffuser for supply air QUICK FACTS Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Non-perforated diffuser face

More information

Nozzle diffuser. Dimensions

Nozzle diffuser. Dimensions Dimensions ØU Ød H 0 ØA Description is a circular diffuser with individually adjustable nozzles. The diffuser is suitable for the horizontal supply of cooled air, where great flexibility in the dispersal

More information

SWIFT Ceiling. Square ceiling air diffuser for supply air QUICK FACTS

SWIFT Ceiling. Square ceiling air diffuser for supply air QUICK FACTS Square ceiling air diffuser for supply air QUICK FACTS Flush design Also available in a version for extract air. Designed for modular suspended ceilings (600 x 600 mm) Quick Access Adapter for systemized

More information

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems Krantz Components Twist outlet DD-N... for ceiling installation Air distribution systems DS E 0. Twist outlet Preliminary remarks and construction design Preliminary remarks Twist outlets for ceiling installation

More information

Step Impulse Diffuser Model SIA

Step Impulse Diffuser Model SIA Step Impulse Diffuser Model SIA Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Phone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Step Impulse Diffuser Model SIA

More information

Krantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

Krantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems Krantz Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems DS E 01.18 Variable twist outlet with guide ring or jet straightener Preliminary remarks The variable

More information

Dimensions. Order code. Materials and finish. lindab ceiling diffusers

Dimensions. Order code. Materials and finish. lindab ceiling diffusers LKP Description LCP is a flush-mounted square diffuser with a circular unperforated face plate for installation in ceiling systems. LCP can be used for both supply and exhaust air. LCP is suitable for

More information

SWIFTTM. Ceiling. Square ceiling air diffuser for supply air

SWIFTTM. Ceiling. Square ceiling air diffuser for supply air SWIFTTM Ceiling SWIFT Ceiling Square ceiling air diffuser for supply air Quick facts Flush design Also available in a version for extract air. Designed for modular suspended ceilings (600 x 600 mm) Quick

More information

series FLOOR

series FLOOR series FLOOR www.koolair.com Floor Series 3 DSA, DSA-PR, DSA-HV and DF-CP-MT Floor swirl diffusers CONTENTS DSA / DSA-PR / DSA-HV diffusers 4 Models and dimensions 5 DSA Selection tables 6 DSA Selection

More information

Plain diffuser. Dimensions

Plain diffuser. Dimensions Dimensions Ø U Ød B C Ø E Ø A Description is a circular diffuser with an unperforated adjustable face plate and can be used for both supply and extract air. The diffuser can be switched between horizontal

More information

3/S3 STAIRCASE SWIRL DIFFUSERS IR, SDV, DSK. v 2.6 (en)

3/S3 STAIRCASE SWIRL DIFFUSERS IR, SDV, DSK. v 2.6 (en) /S v (en) IR, SDV, DSK 8 wwwklimaopremar wwwklimaopremar 9 TBE OF CONTENTS STIRCSE SWIR DIFFUSER - IR Staircase swirl diffuser, type IR Staircase diffuser, for ventilation in areas tat require ig air induction,

More information

CDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L

CDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L Single cone ceiling diffusers for supply air Quick facts Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Imperforated diffuser face

More information

Swirl Diffusers Type DLA 7 and DLA 8

Swirl Diffusers Type DLA 7 and DLA 8 LTG Incorporated Swirl Diffusers Type DLA 7 and DLA 8 LTG Incorporated 1 Corporate Drive, Suite D Spartanburg, SC 93 PO Box 889, Spartanburg, SC 9 USA Tel: 86-599-63 Fax: 86-599-63 e-mail: info@ltg-inc.net

More information

STAIRCASE SWIRL DIFFUSERS

STAIRCASE SWIRL DIFFUSERS OVERVIEW Overview: The KPS series staircase swirl diffusers belong to the underchair diffuser category; ideal for places where the best comfort levels are desired both in temperature and acoustics. Cinemas,

More information

Plain diffuser. Dimensions

Plain diffuser. Dimensions Dimensions ØU Ød 22 37 ØD Description is a circular diffuser with unperforated face plate and can be used for both supply and extract air. is suitable for horizontal supply of cooled air where a high impulse

More information

Mechanical flow-rate controllers

Mechanical flow-rate controllers L D L D L D Mechanical flow-rate controller MRP-1 (Circular) Description With the circular air flow controllers with automated action, the air flow rate is controlled via an asymmetrical control flap pivoting

More information

Krantz Components. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

Krantz Components. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems DS E 01. with guide ring or jet straightener Preliminary remarks The variable twist outlet with guide ring

More information

ALC. ALBATROSS Supply air terminal for large airflows

ALC. ALBATROSS Supply air terminal for large airflows ALBATROSS Supply air terminal for large airflows Quick facts Large airflows Suitable for cooling or heating Manual or motorised adjustment Pressure drop independent of selected spread pattern Can be used

More information

Air distribution systems. Linear whirl outlet WL...

Air distribution systems. Linear whirl outlet WL... Air distribution systems Linear whirl outlet WL... DS 0 E 1.013 Preliminary remarks Mode of operation The linear whirl outlet generates turbulent mixing ventilation. It can be installed on or in a wall

More information

Nozzle diffuser. Dimensions

Nozzle diffuser. Dimensions Nozzle diffuser GTI Dimensions Installation Ød Description GTI is a flexible supply air nozzle that is suitable for ventilation of large areas. The nozzle can be used for both heated and cooled air and

More information

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air Ceiling Square ceiling air diffuser for supply air and extract air Quick facts Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed

More information

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR Air distribution systems Jet nozzle DW-N... Swivel jet nozzle DW-V... Twist nozzle DW-V-...-DR DS E 01. Jet nozzle and twist nozzle Preliminary remarks Jet nozzle DW N Swivel jet nozzle DW V Twist nozzle

More information

Air distribution systems. Radial outlet RA-N2...

Air distribution systems. Radial outlet RA-N2... Air distribution systems Radial outlet RA-N... DS E 0.01 Radial outlet RA-N Preliminary remark KRANTZ KOMPONENTEN radial outlets RA-N have fixed radial vanes and are available with circular or square face.

More information

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS For exhaust air 91% free area Handles large airflows Cleanable Can be used with commissioning box ALS Standard colour

More information

Displacement Flow Diffusers

Displacement Flow Diffusers T 1.3/1/EN/2 Displacement Flow Diffusers Types QLE QLF for low turbulence air supply TROX GmbH Telephone +9/28 /2 02-0 Telefax +9/28 /26 Heinrich-Trox-Platz e-mail trox@trox.de D0 Neukirchen-Vluyn www.troxtechnik.com

More information

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with

More information

Air distribution systems. Adjustable radial outlet RA-V...

Air distribution systems. Adjustable radial outlet RA-V... Air distribution systems Adjustable radial outlet RA-V... DS E 0.2013 Construction design Preliminary remarks KRANTZ KOMPONENTEN has developed its wellknown, successful radial outlet into an adjustable

More information

Linear ceiling diffuser

Linear ceiling diffuser L-0--01e Linear ceiling diffuser Type LDD / LDDL Contents Realisation Application Safety instructions Contents Realisation Application Safety instructions Dimensions 3 Dimensions Installation Quick selection

More information

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS Square ceiling air diffuser for supply air and extract air QUICK FACTS Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed for

More information

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor

More information

Air distribution systems. Adjustable induction outlet IN-V...

Air distribution systems. Adjustable induction outlet IN-V... ir distribution systems djustable induction outlet IN-V... DS E 0. Construction and function Preliminary remarks In addition to its induction outlet with preset discharge direction ), KRNTZ KOMPONENTEN

More information

CIRCO. Sound-attenuating transfer unit QUICK FACTS

CIRCO. Sound-attenuating transfer unit QUICK FACTS Sound-attenuating transfer unit QUICK FACTS Supplied in pairs For the transfer of air through a wall Fits in a circular cut opening Simple to install Mounting frame integrated into the transfer diffuser

More information

Linear diffuser. Description

Linear diffuser. Description A C B + D Description is a rectangular linear diffuser in aluminium. is suitable for both supply and exhaust air. is equipped with air guide baffles, making it possible to use for horizontal supply air.

More information

Multi-cone diffuser. Dimensions

Multi-cone diffuser. Dimensions Dimensions Vertical Ød 8 Max. H ØU ØD Horizontal Ød Description is an adjustable circular multi-cone diffuser, which is typically used for supply air. The diffuser can be switched between horizontal and

More information

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN Linear Diffusers / 8 HELLA Linear slot diffuser Ordering codes HELLA - Linear diffuser HELLA - Number of slots... Diffuser length L (mm) ) Increment mm... Deflector colour Damper Diffuser construction

More information

Worth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma.

Worth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma. Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia

More information

SV-2, SV-1, AVS, AVSL, SI Grilles

SV-2, SV-1, AVS, AVSL, SI Grilles Grilles SV-2, SV-1, AVS, AVS-L TECHNICAL DATA - 2004 page 351 SV-2, SV-1, AVS, AVSL, SI Grilles SV-2 SV-1 47 (H-17) x (W-17) (H-12) x (W-12) AVS, SI AVSL S SV, AVS, AVSL and SI grilles are designed for

More information

BNA Series. PLENUM FAN with Backward Wheels

BNA Series. PLENUM FAN with Backward Wheels BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.

More information

series 50-PR Square perforated face diffusers

series 50-PR Square perforated face diffusers series 50-PR Square perforated face diffusers www.koolair.com Series 50-PR 1 Square perforated face diffusers CONTENTS Square perforated face diffusers 54-FR Description 2 Coding and dimensions 3 Quick

More information

KSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16

KSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16 Linear diffusers 1 / 1 KSV Slot diffusers Ordering code Number of slots Diffuser Length (mm) KSV - 1... - 19 Description KSV is an air terminal element primarily designated for air supply. It is suitable

More information

Multi-cone diffuser. Dimensions. Description FKD is an adjustable circular multi-cone diffuser, which is typically used for supply air.

Multi-cone diffuser. Dimensions. Description FKD is an adjustable circular multi-cone diffuser, which is typically used for supply air. Dimensions Vertical Ø N D F G Ø A Ø B C Horizontal Description is an adjustable circular multi-cone diffuser, which is typically used for supply air. The diffuser can be switched between horizontal and

More information

Supply air nozzle. Dimensions. DAD-0 With flange for mounting on a wall or duct side.

Supply air nozzle. Dimensions. DAD-0 With flange for mounting on a wall or duct side. A imensions A-0 With flange for mounting on a wall or duct side. Ø ( ) 0 Ø F Ø Nom 0 0 Ø A Ø B Ø E escription A is an adjustable supply air nozzle suitable for ventilation of large areas where long throws

More information

2/S12 DIFFUSER FOR HORIZONTAL OR VERTICAL DISCHARGE DHV. v 3.3 (en)

2/S12 DIFFUSER FOR HORIZONTAL OR VERTICAL DISCHARGE DHV. v 3.3 (en) 2/S12 v (en) DIFFUSER FOR HORIZONTAL OR VERTICAL DISCHARGE DHV 6 7 wwwklimaopremahr wwwklimaopremahr TABLE OF CONTENTS Horizontalvertical diffuser 9 Ordering key 1 Selection diagrams 1 DHV Ceiling diffuser

More information

variable flow dampers

variable flow dampers Constant-/ DAU, DAEU, DAVU Summary DAU - manual single flow unit DAEU - motorized twin flow unit DAVU - motorized variable flow unit Diameters Ø 0 Flow range 0 l/s ( m³/h) Pressure range Pa (over the unit)

More information

DBQ Painted four four-way square square diffuseurs M A D E L

DBQ Painted four four-way square square diffuseurs M A D E L Painted four-way square diffuseurs MADEL The four-way square diffusers meet the functional and architectural requirements of modern updated locations. Its geometrical shape, fits perfectly in the style

More information

AX6 adjustable blades swirl diffusers

AX6 adjustable blades swirl diffusers AX6 adjustable blades swirl diffusers AX6 series swirl diffusers are designed to be applied in air conditioning, ventilation and heating in different premises from 2,6 meters high and temperature differential

More information

Siv-inn School. Complete air-supply solution for school premises. Ensures excellent air supply Cleanable Reinforced front Ideal for renovation work

Siv-inn School. Complete air-supply solution for school premises. Ensures excellent air supply Cleanable Reinforced front Ideal for renovation work GB0702 11.15 Complete air-supply solution for school premises Ensures excellent air supply Cleanable Reinforced front Ideal for renovation work TROX Trox Norge AS PO Box NO-2712 Brandbu Telefon +47 61

More information

AXO adjustable vanes swirl diffusers

AXO adjustable vanes swirl diffusers klin SYSTEM XO adjustable vanes swirl diffusers M DEL The XO swirl diffusers are designed to be applied in air conditioning ventilation and heating systems.they can be mounted in false ceilings or suspended

More information

2/S11. v 2.6 (en) SLOT DIFFUSER

2/S11. v 2.6 (en) SLOT DIFFUSER / v.6 (en) www.klimaoprema.hr www.klimaoprema.hr TABLE O CONTENT lot diffuser, type... 7 election diagrams... Ordering key... Corner section... Horizontal one-sided discharge Definition of symbols: Vp

More information

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus. Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia Regula

More information

DCG adjustable core circular diffusers

DCG adjustable core circular diffusers Lievore, Altherr & Molina DCG adjustable core circular diffusers The DCG series diffusers are designed to be used in air-conditioning, ventilation and heating in premises from,6 meters high. They can be

More information

NOP, NOT and NOX. Adaptable, flexible supply air diffusers with ultra low height for free installation. climecon.fi 07.16

NOP, NOT and NOX. Adaptable, flexible supply air diffusers with ultra low height for free installation. climecon.fi 07.16 NOP, NOT and NOX Adaptable, flexible supply air diffusers with ultra low height for free installation 07.16 NOP, NOT and NOX The most outstanding features of the NOP, NOT and NOX supply air diffusers are

More information

NEO-V. Smoke Control Damper SMOKE CONTROL FUNCTION APPLICATION DESCRIPTION. in libraries of

NEO-V. Smoke Control Damper SMOKE CONTROL FUNCTION APPLICATION DESCRIPTION. in libraries of OKE CONTRO in libraries of EI (v ew -h ow -i o) 0 C 000 AA multi EN -:0 EN -:0 Certificate of Constancy of Performance -CPR-0/00 Damper tightness class: Casing tightness class: C EN-:0 FUNCTION The smoke

More information

AIR HANDLING REFERENCE CATALOGUE PRODUCT SUMMARY COMPANY PROFILE HOW TO CONTACT US.

AIR HANDLING REFERENCE CATALOGUE PRODUCT SUMMARY COMPANY PROFILE HOW TO CONTACT US. AIR HANDLING REFERENCE CATALOGUE PRODUCT SUMMARY COMPANY PROFILE HOW TO CONTACT US www.bradflo.com.au HOME 1 GRILLES & LOUVRES GRILLES & LOUVRES Chapter Description Product Code 1.11 Double deflection

More information

Connections Standard. Description

Connections Standard. Description Section Convectors Description Connections Standard without built-in valve or version with built-in valve Air vent, Drain Fixing Pressure versions, Fittings, Surface finishes, Special versions Heat output

More information

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus. Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia Regula

More information

Valve Supply and exhaust air

Valve Supply and exhaust air IRY Dimensions Description The valve is designed for installation at a wall or in a ceiling. It can be used for new-build and for replacement. Its smart grip function ensures an easy installation. Its

More information

series KAT Acoustic air transfer units

series KAT Acoustic air transfer units series Acoustic air transfer units www.koolair.com 1 Acoustic Air Transfer Unit CONTENTS Acoustic Air Transfer Unit 2 Dimensions 3 Technical Data 5 Product Codes 7 2 Acoustic Air Transfer Unit - Description

More information

The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout

The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout NOISE CONTROL IN VENTILATING SYSTEMS INTRODUCTION The diagram below shows the various noise sources and transmission paths of plant rooms and ventilation systems. For the ventilation system this can be

More information

FIXED ROUND CEILING DIFFUSERS & GRILLES APPLICATION

FIXED ROUND CEILING DIFFUSERS & GRILLES APPLICATION SH.RDI.F1 SH.RDI.F FIXED ROUND CEILING DIFFUSERS & GRILLES APPLICATION SH.RDI.F Shahrokhi fixed round ceiling diffusers & grilles are designed to suit H.V.A.C applications for ceiling mounting or exposed

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

AIR TECH SYSTEMS. Technical Brochure. LTG Air Diffusers. Linear air diffusers LDB. Installation in ceilings, walls and sills

AIR TECH SYSTEMS. Technical Brochure. LTG Air Diffusers. Linear air diffusers LDB. Installation in ceilings, walls and sills AIR TECH SYSTEMS Technical Brochure LTG Air Diffusers Linear air diffusers Installation in ceilings, walls and sills Technicalbrochure Linear air diffusers LTG Comfort Air Technology Air-Water Systems

More information

Use. Worth noting. Key figures. Installation. lindab fasadium

Use. Worth noting. Key figures. Installation. lindab fasadium Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Atrium / Loggia Regula

More information

PET PETI PET/PETI. Supply air diffuser for ceilings

PET PETI PET/PETI. Supply air diffuser for ceilings Supply air diffuser for ceilings PET PETI The TR connection box is an optional accessory for PET and PETI. Description The square perforated ceiling diffuser is best suitable for cofort ventilation. The

More information

textile duct texi-jet textile duct high induction diffusion through perforations applications advantages recommandations and limits of use 5.

textile duct texi-jet textile duct high induction diffusion through perforations applications advantages recommandations and limits of use 5. texi-jet Page 1/5 high induction diffusion through perforations The TEXI-JET has been designed for high air velocity diffusion (7 < V < 15 m/s). This diffusion is ensured through rows of perforations designed

More information

Air Diffusion Designing for Comfort

Air Diffusion Designing for Comfort Air Diffusion Designing for Comfort Occupant Comfort Air Diffusion Selection ADPI Air Diffusion Performance index Ventilation Effectiveness Induction Room Space Induction Design Criteria ISO7730 ASHRAE

More information

Hudevad P100. Technical datasheet

Hudevad P100. Technical datasheet Technical datasheet Key benefits Available in three depths Highly flexible in use Integrated top grille Harmonious and finished look Kundenedfal Low, streamlined design Ideal in front of glazing to prevent

More information

The OCTANORM system components set a new standard in shop design.

The OCTANORM system components set a new standard in shop design. O C TA N O R M S H O P S Y S T E M S. A B R I E F I N T R O D U C T I O N. The OCTANORM system components set a new standard in shop design. The wide range of aluminum profiles, the well designed accessories

More information

Damper - circular. Dimensions. Description. Ordering example. comfort vav

Damper - circular. Dimensions. Description. Ordering example. comfort vav Dimensions L D B C H Ød Description is a circular control and shut-off damper, which meets the air tightness requirements of DS class. The damper can be used for pressure or volume flow regulation with

More information

Industrial Air Diffuser Type DLD for Heating and Cooling

Industrial Air Diffuser Type DLD for Heating and Cooling LTG Incorporated Industrial Air Diffuser Type DLD for Heating and Cooling LTG Incorporated Corporate Drive, Suite E Spartanburg, SC 20 PO Box 288, Spartanburg, SC 20 USA Tel: 8--0 Fax: 8-- e-mail: info@ltg-inc.net

More information

Section 8 Column radiators

Section 8 Column radiators Section s Description Connections Standard without built-in valve -or- Version with built-in valve Air vent, Drain Fixing and mounting Pressure versions, Fittings, Surface finishes, Special versions eat

More information

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1 EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS FCP 2008 testing procedures FCP acoustical test method pag. 1 CONTENTS 1 - PURPOSE... 3 2 - NORMATIVE REFERENCES... 3 3 - DEFINITIONS... 3 3.1

More information

Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett.

Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett. & S Contact, Overview, Index Guideline heating and cooling Plexus Professor Pilot Architect & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium H & C /Loggia Regula Drypac Lighting TEKNOsim

More information

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H Type Series Booklet.5/7-0 G CPK-H Standardized Chemical Pumps to EN 5/ISO 5/ISO 599, heatable Automation products available: Hya-Drive Hyamaster hyatronic Fields of Application CPK-H pumps are used for

More information

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm Tangential Fans Series TW Impeller diameter mm and 0 mm 105 Corporate Drive, Suite E Spartanburg, SC 293 PO Box 2889, Spartanburg, SC 294 USA Tel: 864-599-63 Fax: 864-599-6344 e-mail: info@ltg-inc.net

More information

Attenuation. Witt&Sohn AG Oct-14

Attenuation. Witt&Sohn AG Oct-14 Noise Generation & Attenuation CONTENT Noise Generation & Attenuation 1. General 2. Jet fans 3. Axial Fans 2 General Sound Power L W depends on Vibrations Number of blades Turbulences Rotational speed

More information

HVAC Clinic. Duct Design

HVAC Clinic. Duct Design HVAC Clinic Duct Design Table Of Contents Introduction... 3 Fundamentals Of Duct Design... 3 Pressure Changes In A System... 8 Example 1... 13 Duct Design Methods... 15 Example 2... 15 Introduction The

More information

FRB. Exposed passive chilled beam for suspended installation

FRB. Exposed passive chilled beam for suspended installation Exposed passive chilled beam for suspended installation QUICK FACTS FRB is a passive chilled beam for comfort cooling especially designed for visible/suspended installation in the room. High cooling capacity,

More information

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1 Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS No. E14/A1 The complete range of our products is presented in the specific catalogues: HOSE REELS CATALOGUE No. E14/A2 HOSE REELS CATALOGUE

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7 ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan

More information

CNA-CNB. Centrifugal fans

CNA-CNB. Centrifugal fans NA-NB entrifugal fans Product facts Product Single-inlet low-pressure fans with backward-curved blades. Use In industrial ventilation systems for uncontaminated, non-corrosive air, max. 70 º, where a low

More information

CMA - B - C - D - CMR

CMA - B - C - D - CMR Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

zehnder stratos CS CS CS CSW CSW Product Overview Model Code (example)

zehnder stratos CS CS CS CSW CSW Product Overview Model Code (example) Product Overview Model Code (example) CS-15-19 Depth (cm) eight (cm) CS = Convector Stratos CS = Convector Stratos with rear dummy panel CS-..-10 CS-..-13 No. of panels: 2 No. of fins: 2 Depth: 98mm eight:

More information