textile duct texi-jet textile duct high induction diffusion through perforations applications advantages recommandations and limits of use 5.
|
|
- Nelson Webster
- 6 years ago
- Views:
Transcription
1 texi-jet Page 1/5 high induction diffusion through perforations The TEXI-JET has been designed for high air velocity diffusion (7 < V < 15 m/s). This diffusion is ensured through rows of perforations designed for your project by our aeraulic engineering department. This method based on high air induction (rate > 20), offers an excellent air distribution effi ciency (heating and cooling) combined with the control of residual speed, avoiding any «air draught effect». applications Heating and cooling of large volumes large and average size stores, exhibition halls Auditorium, amphitheaters, theaters, concert halls... sports halls, multi-purpose halls Heating and cooling of high industrial storage warehouses needing a homogeneous and controlled temperature. Heating and cooling of sensitive industrial production premises, demanding regarding the control of residual speeds or high thermal applications : advantages printing halls electronics metallurgy plastic injection... High induction rate (> 20). Good control over residual air velocities and excellent comfort even with strong ΔT. High effi ciency for the heating of high premises (H > 8 m). The ideal solution to heat and cool premises whose height is between 4 m < H < 8 m and where comfort and a homogenous repartition of the air are wanted. Suitable to heat up to 200 W/m² and up to 300 W/m² when in cooling mode - Air fl ow up to 450 m3/h/ml. ducts do not clog. recommandations and limits of use To be avoided for low height premises (H < 4 m). The sizing of the network and of the ducts (quantity, length, perforation plan) must be set at the beginning of the project.
2 texi-jet possible fabrics All fabrics having a permeability below 50 m3/h/m² under 120 Pa as well as technical PVC fabrics can be used. Fabric codification PM1/E PVC - M1 VPU M0 RAL 7040 Type of fabric Polyester M1 fi re rating (availaible without fi re rating) Double faced polyester coated with PVC M1 fi re rating (available without fi re rating) Double faced fi ber glass fabric coated with polyurethane M0 fi re rating Black RAL 5005 *Standard colours PVC PVC M1 in white only Gree, RAL 6032 Red RAL 3020 Weight g/m² The indicated colours only apply for the fabric itself. Standard colour Permeability under 120 Pa 160 ** *** Black <1 Yellow RAL 1023 Green RAL 6032 Characteristics Washable in machine according to our instructions Washable with high pressure jet Can be dusted Non washable RAL 5005 RAL 5012 **Standard colours PM1 160g Red RAL 3020 RAL 7040 Page 2/5
3 Page 3/5 Selection chart for a circular duct Charts A and B : diameter s selection depending on the input air flow. Chart A Chart B
4 selection chart for a 1/2 circular duct Chart C Duct diameter Chart D Duct diameter Information and data can not be considered as contractual. Design and data changes may occur without notice during F2A s continuous product development. Charts C et D : diameter s selection depending on the input air flow. 2014/07 Page 4/5
5 Example of high induction texi-jet ductwork Page 5/5 Heating and cooling of a large DIY store 6.5 m 35 m Duct Ø 800 Duct Ø 800 Airflow dispatch through each duct available pressure 17 m 40 m Rows of perforations 17.5 m Duct Ø1250 A collector Ø1600 dispatches the airflow over 3 ducts: 2 ducts Ø duct Ø1250 (see chart C and D) Airflow per duct: duct Ø800 = m3/h per duct duct Ø1250 = m3/h Length of each duct: duct Ø800 = 13,7 m each duct Ø1250 = 23,7 m collector Ø1600 = 24,5 m 1. Surface to treat for each duct : S g S g = Length x Air throw 2. Total surface to treat : S t S t =sum of S g 3. «Average surface airflow : Q s Q s = Q t /S t 4. Airflow per duct : Q g Q g = Q s x S g The total available pressure of the fan P t is given by the following formula : P t = P stat + P dyn With : P stat = Pressure drop caused by the air passing through the perforations. It depends on the air diffusion velocity (here 9,7 m/s) Room s dimensions : 40 m x 35 m x 6,5 m ΔT hot = + 15 C ; ΔT cold = - 7 C Total airflow : m 3 /h 4 rows of perforations on each side positioned 50 (towards the bottom) from the horizontal shaft Air diffusion velocity through the perforations V s = 12,6 m/s P dyn = Dynamic pressure of the air when it enters the duct (see charts A à D ) here P dyn = 42 Pa
Multi-cone diffuser. Dimensions. Description FKD is an adjustable circular multi-cone diffuser, which is typically used for supply air.
Dimensions Vertical Ø N D F G Ø A Ø B C Horizontal Description is an adjustable circular multi-cone diffuser, which is typically used for supply air. The diffuser can be switched between horizontal and
More informationMulti-cone diffuser. Dimensions
Dimensions Vertical Ød 8 Max. H ØU ØD Horizontal Ød Description is an adjustable circular multi-cone diffuser, which is typically used for supply air. The diffuser can be switched between horizontal and
More informationDimensions. Order code. Materials and finish. lindab ceiling diffusers
LKP Description LCP is a flush-mounted square diffuser with a circular unperforated face plate for installation in ceiling systems. LCP can be used for both supply and exhaust air. LCP is suitable for
More informationKrantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems
Krantz Components Twist outlet DD-N... for ceiling installation Air distribution systems DS E 0. Twist outlet Preliminary remarks and construction design Preliminary remarks Twist outlets for ceiling installation
More informationPlain diffuser. Dimensions
Dimensions Ø U Ød B C Ø E Ø A Description is a circular diffuser with an unperforated adjustable face plate and can be used for both supply and extract air. The diffuser can be switched between horizontal
More informationPlain diffuser. Dimensions
Dimensions ØU Ød 22 37 ØD Description is a circular diffuser with unperforated face plate and can be used for both supply and extract air. is suitable for horizontal supply of cooled air where a high impulse
More informationStep Impulse Diffuser Model SIA
Step Impulse Diffuser Model SIA Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Phone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Step Impulse Diffuser Model SIA
More informationNozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.
Nozzles About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement diffusers VAV
More informationNozzle diffuser. Dimensions
Dimensions ØU Ød H 0 ØA Description is a circular diffuser with individually adjustable nozzles. The diffuser is suitable for the horizontal supply of cooled air, where great flexibility in the dispersal
More informationSupply air nozzle. Dimensions. DAD-0 With flange for mounting on a wall or duct side.
A imensions A-0 With flange for mounting on a wall or duct side. Ø ( ) 0 Ø F Ø Nom 0 0 Ø A Ø B Ø E escription A is an adjustable supply air nozzle suitable for ventilation of large areas where long throws
More informationNozzle diffuser. Dimensions
Nozzle diffuser GTI Dimensions Installation Ød Description GTI is a flexible supply air nozzle that is suitable for ventilation of large areas. The nozzle can be used for both heated and cooled air and
More informationAX6 adjustable blades swirl diffusers
AX6 adjustable blades swirl diffusers AX6 series swirl diffusers are designed to be applied in air conditioning, ventilation and heating in different premises from 2,6 meters high and temperature differential
More informationAir distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR
Air distribution systems Jet nozzle DW-N... Swivel jet nozzle DW-V... Twist nozzle DW-V-...-DR DS E 01. Jet nozzle and twist nozzle Preliminary remarks Jet nozzle DW N Swivel jet nozzle DW V Twist nozzle
More informationAir distribution systems. Adjustable induction outlet IN-V...
ir distribution systems djustable induction outlet IN-V... DS E 0. Construction and function Preliminary remarks In addition to its induction outlet with preset discharge direction ), KRNTZ KOMPONENTEN
More informationKrantz Components. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems
Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems DS E 01. with guide ring or jet straightener Preliminary remarks The variable twist outlet with guide ring
More informationKrantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems
Krantz Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems DS E 01.18 Variable twist outlet with guide ring or jet straightener Preliminary remarks The variable
More informationNOP, NOT and NOX. Adaptable, flexible supply air diffusers with ultra low height for free installation. climecon.fi 07.16
NOP, NOT and NOX Adaptable, flexible supply air diffusers with ultra low height for free installation 07.16 NOP, NOT and NOX The most outstanding features of the NOP, NOT and NOX supply air diffusers are
More informationSTAIRCASE SWIRL DIFFUSERS
OVERVIEW Overview: The KPS series staircase swirl diffusers belong to the underchair diffuser category; ideal for places where the best comfort levels are desired both in temperature and acoustics. Cinemas,
More information2/S12 DIFFUSER FOR HORIZONTAL OR VERTICAL DISCHARGE DHV. v 3.3 (en)
2/S12 v (en) DIFFUSER FOR HORIZONTAL OR VERTICAL DISCHARGE DHV 6 7 wwwklimaopremahr wwwklimaopremahr TABLE OF CONTENTS Horizontalvertical diffuser 9 Ordering key 1 Selection diagrams 1 DHV Ceiling diffuser
More informationseries FLOOR
series FLOOR www.koolair.com Floor Series 3 DSA, DSA-PR, DSA-HV and DF-CP-MT Floor swirl diffusers CONTENTS DSA / DSA-PR / DSA-HV diffusers 4 Models and dimensions 5 DSA Selection tables 6 DSA Selection
More informationVariable swirl diffusers
Swirl diffusers, Variable swirl diffuser OD- Application Diffuser is designed for air conditioning of rooms with floor to ceiling highs of to 0 m and high induction requirements. It is suitable for large
More informationVentilation 5 Fans Vladimír Zmrhal (room no. 814) http://users.fs.cvut.cz/~zmrhavla/index.htm Dpt. Of Environmental Engineering 1 Introduction Fans air pump that creates a pressure difference and causes
More informationseries 50-PR Square perforated face diffusers
series 50-PR Square perforated face diffusers www.koolair.com Series 50-PR 1 Square perforated face diffusers CONTENTS Square perforated face diffusers 54-FR Description 2 Coding and dimensions 3 Quick
More informationKrantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09.
Krantz Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 86 E 09./1 with square and circular blade array Preliminary remark The radial slot outlet
More informationKSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16
Linear diffusers 1 / 1 KSV Slot diffusers Ordering code Number of slots Diffuser Length (mm) KSV - 1... - 19 Description KSV is an air terminal element primarily designated for air supply. It is suitable
More informationDCG adjustable core circular diffusers
Lievore, Altherr & Molina DCG adjustable core circular diffusers The DCG series diffusers are designed to be used in air-conditioning, ventilation and heating in premises from,6 meters high. They can be
More informationAir distribution systems. Linear whirl outlet WL...
Air distribution systems Linear whirl outlet WL... DS 0 E 1.013 Preliminary remarks Mode of operation The linear whirl outlet generates turbulent mixing ventilation. It can be installed on or in a wall
More informationDisplacement Flow Diffusers
T 1.3/1/EN/2 Displacement Flow Diffusers Types QLE QLF for low turbulence air supply TROX GmbH Telephone +9/28 /2 02-0 Telefax +9/28 /26 Heinrich-Trox-Platz e-mail trox@trox.de D0 Neukirchen-Vluyn www.troxtechnik.com
More informationSlot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14
, Round duct diffusers D-, D- Application D- and D- slot diffusers are designed for the supply of air in rooms with floor to ceiling heights of.5 to m for supplying either cold or warm air, in particular
More informationKrantz. RL-C2 radial slot outlet. Air distribution systems
RL-C2 radial slot outlet Air distribution systems DS E 04.1 Introduction The RL-C2 radial slot outlet with circular face generates a turbulent mixed flow. It is used for supply and return air distribution
More informationSupply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia Regula
More informationWorth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma.
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia
More informationCircular duct grille
Dimensions B+0 A+0 A B Description is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air. The
More informationALC. ALBATROSS Supply air terminal for large airflows
ALBATROSS Supply air terminal for large airflows Quick facts Large airflows Suitable for cooling or heating Manual or motorised adjustment Pressure drop independent of selected spread pattern Can be used
More informationPET PETI PET/PETI. Supply air diffuser for ceilings
Supply air diffuser for ceilings PET PETI The TR connection box is an optional accessory for PET and PETI. Description The square perforated ceiling diffuser is best suitable for cofort ventilation. The
More informationSwirl diffusers, Variable swirl diffusers Swirl diffusers
IMP Klima, Variable swirl diffusers Swirl diffuser OD- Fixed grille For air supply or exhaust Recommended temperature difference between supplied and internal air in the room is between 0 to 0 K Low static
More informationThe energy performance of an airflow window
The energy performance of an airflow window B.(Bram) Kersten / id.nr. 0667606 University of Technology Eindhoven, department of Architecture Building and Planning, unit Building Physics and Systems. 10-08-2011
More informationAir distribution systems. Radial outlet RA-N2...
Air distribution systems Radial outlet RA-N... DS E 0.01 Radial outlet RA-N Preliminary remark KRANTZ KOMPONENTEN radial outlets RA-N have fixed radial vanes and are available with circular or square face.
More informationSwirl Diffusers Type DLA 7 and DLA 8
LTG Incorporated Swirl Diffusers Type DLA 7 and DLA 8 LTG Incorporated 1 Corporate Drive, Suite D Spartanburg, SC 93 PO Box 889, Spartanburg, SC 9 USA Tel: 86-599-63 Fax: 86-599-63 e-mail: info@ltg-inc.net
More informationSwirl diffusers, Variable swirl diffusers
0 Variable swirl diffusers SLOT IFFUSERS, ROUN UCT IFFUSERS SWIRL IFFUSERS, VARIABLE SWIRL IFFUSERS CIRCULAR IFFUSERS, SQUARE IFFUSERS VENTILATING GRILLES, VENTILATING VALVES, Variable swirl diffusers
More informationSlot diffuser. Type VSD35 2/2.6/B/3. with 35 mm wide slot
2/2.6/B/3 Slot diffuser Type VSD35 with 35 mm wide slot TROX UK Ltd Telephone +44 (0) 1842 754545 Caxton Way Telefax +44 (0) 1842 763051 Thetford e-mail trox@troxuk.co.uk Norfolk IP24 3SQ www.troxuk.co.uk
More informationHELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN
Linear Diffusers / 8 HELLA Linear slot diffuser Ordering codes HELLA - Linear diffuser HELLA - Number of slots... Diffuser length L (mm) ) Increment mm... Deflector colour Damper Diffuser construction
More informationSupply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia Regula
More informationLinear ceiling diffuser
L-0--01e Linear ceiling diffuser Type LDD / LDDL Contents Realisation Application Safety instructions Contents Realisation Application Safety instructions Dimensions 3 Dimensions Installation Quick selection
More informationGTH. Rectangular double deflection grille QUICK FACTS
Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Available in alternative colours A
More informationDBQ Painted four four-way square square diffuseurs M A D E L
Painted four-way square diffuseurs MADEL The four-way square diffusers meet the functional and architectural requirements of modern updated locations. Its geometrical shape, fits perfectly in the style
More informationAalborg Universitet. Comparison between Different Air Distribution Systems Nielsen, Peter Vilhelm. Publication date: 2006
Aalborg Universitet Comparison between Different Air Distribution Systems Nielsen, Peter Vilhelm Publication date: 2006 Document Version Publisher's PDF, also known as Version of record Link to publication
More informationBNA Series. PLENUM FAN with Backward Wheels
BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.
More informationAir Diffusion Designing for Comfort
Air Diffusion Designing for Comfort Occupant Comfort Air Diffusion Selection ADPI Air Diffusion Performance index Ventilation Effectiveness Induction Room Space Induction Design Criteria ISO7730 ASHRAE
More informationWillkommen. Welcome. Bienvenue. Ventilation energy efficiency of fans and drives Energy recovery and energy efficiency in ventilation technology
Willkommen Bienvenue Welcome Ventilation energy efficiency of fans and drives Energy recovery and energy efficiency in ventilation technology Prof. Dr.-Ing. Christoph Kaup c.kaup@umwelt-campus.de Components
More informationGRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS
Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS For exhaust air 91% free area Handles large airflows Cleanable Can be used with commissioning box ALS Standard colour
More informationVentilating grilles, Ventilating valves
01 Ventilating grilles Grilles with thermostatic regulation Special grilles Ventilating valves Staircase swirl diffusers SOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS CIRCUAR
More informationWISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS
Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor
More informationOperation and sound power characteristics of cooling fans in surrounding structures
20 Operation and sound power characteristics of cooling fans in surrounding structures Johannes Hyrynen, VTT Industrial Systems P.O.Box 1307 33101Tampere Finland This paper gives a view of means to design
More informationPELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS
Square ceiling air diffuser for supply air and extract air QUICK FACTS Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed for
More informationSiv-inn School. Complete air-supply solution for school premises. Ensures excellent air supply Cleanable Reinforced front Ideal for renovation work
GB0702 11.15 Complete air-supply solution for school premises Ensures excellent air supply Cleanable Reinforced front Ideal for renovation work TROX Trox Norge AS PO Box NO-2712 Brandbu Telefon +47 61
More informationCircular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct.
Dimensions B+0 A+0 A B Description RGS is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air.
More informationSwemaMan 7 Operating instructions vers 1.13 MB_CW
SwemaMan 7 Operating instructions vers 1.13 MB_CW20180425 WARNING! Before start measuring please read chapter 6. Settings (Set). At delivery k2-factor is turned on. SWEMA AB Pepparv. 27 123 56 FARSTA Tel:
More informationCDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L
Single cone ceiling diffusers for supply air Quick facts Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Imperforated diffuser face
More informationSWIFT Ceiling. Square ceiling air diffuser for supply air QUICK FACTS
Square ceiling air diffuser for supply air QUICK FACTS Flush design Also available in a version for extract air. Designed for modular suspended ceilings (600 x 600 mm) Quick Access Adapter for systemized
More informationTIR100-2 Measurement of Thermal Emissivity
TIR100-2 Measurement of Thermal Emissivity Dr. Thomas Meisel INGLAS GmbH & Co. KG Introduction Some basic physics Principles of measurement pren 15976 Working with the TIR100-2 Practical course INGLAS
More informationSWIRL DIFFUSERS SWIRL DIFFUSERS OD-8
SWIRL IFFUSERS O- St RAL 900 Swirl diffuser O- Square or round front plate with radial deflector arrangement Plastic deflectors Possible volume control damper in spigot C SWIRL IFFUSERS O- K 00/ O- R 00/
More informationCDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS
Circular ceiling diffuser for supply air QUICK FACTS Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Non-perforated diffuser face
More informationSWIFTTM. Ceiling. Square ceiling air diffuser for supply air
SWIFTTM Ceiling SWIFT Ceiling Square ceiling air diffuser for supply air Quick facts Flush design Also available in a version for extract air. Designed for modular suspended ceilings (600 x 600 mm) Quick
More informationIndustrial Air Diffuser Type DLD for Heating and Cooling
LTG Incorporated Industrial Air Diffuser Type DLD for Heating and Cooling LTG Incorporated Corporate Drive, Suite E Spartanburg, SC 20 PO Box 288, Spartanburg, SC 20 USA Tel: 8--0 Fax: 8-- e-mail: info@ltg-inc.net
More informationzehnder stratos CS CS CS CSW CSW Product Overview Model Code (example)
Product Overview Model Code (example) CS-15-19 Depth (cm) eight (cm) CS = Convector Stratos CS = Convector Stratos with rear dummy panel CS-..-10 CS-..-13 No. of panels: 2 No. of fins: 2 Depth: 98mm eight:
More informationSwirl Diffuser. Type SDW T 2.2/1/B/1. recommended for room heights from approx m
T 2.2/1/B/1 Swirl Diffuser Type SDW recommended for room heights from approx. 2.60... 4.00 m TROX UK Ltd Caxton Way Thetford Norfolk IP24 3SQ Telephone +44(0) 1842 54545 Telefax +44(0) 1842 63051 e-mail
More informationSTUDY ON THE THERMAL PERFORMANCE AND AIR DISTRIBUTION OF A DISPLACEMENT VENTILATION SYSTEM FOR LARGE SPACE APPLICATION
STUDY ON THE THERMAL PERFORMANCE AND AIR DISTRIBUTION OF A DISPLACEMENT VENTILATION SYSTEM FOR LARGE SPACE APPLICATION K Sakai 1*, E Yamaguchi 2, O Ishihara 3 and M Manabe 1 1 Dept. of Architectural Engineering,
More informationThe measurement of tritium in environmental water samples
The measurement of tritium in environmental water samples 1. Introduction The Hidex 300 SL automatic TDCR liquid scintillation provides an excellent solution for the determination of H-3 in drinking water.
More informationCFD as a Tool for Thermal Comfort Assessment
CFD as a Tool for Thermal Comfort Assessment Dimitrios Koubogiannis dkoubog@teiath.gr G. Tsimperoudis, E. Karvelas Department of Energy Technology Engineering Technological Educational Institute of Athens
More information2/S11. v 2.6 (en) SLOT DIFFUSER
/ v.6 (en) www.klimaoprema.hr www.klimaoprema.hr TABLE O CONTENT lot diffuser, type... 7 election diagrams... Ordering key... Corner section... Horizontal one-sided discharge Definition of symbols: Vp
More informationWöhler DP 700 Leakage Tester
LEAKAGE CLASS ACHIEVED? Wöhler DP 700 Leakage Tester The Measure of Technology Made in Germany COLOR DISPLAY EINFACHE BEDIENUNG Wöhler DP 700 Leakage Tester Just 3 entries to classify an air ductwork system
More informationThe diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout
NOISE CONTROL IN VENTILATING SYSTEMS INTRODUCTION The diagram below shows the various noise sources and transmission paths of plant rooms and ventilation systems. For the ventilation system this can be
More informationPELICAN Ceiling. Square ceiling air diffuser for supply air and extract air
Ceiling Square ceiling air diffuser for supply air and extract air Quick facts Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed
More informationApplied Fluid Mechanics
Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and
More informationNumerical Optimization of Heating for High- Speed Rotating Cup by Means of Multiphysics Modeling and its Experimental Verification
Numerical Optimization of Heating for High- Speed Rotating Cup by Means of Multiphysics Modeling and its Experimental Verification September 17-19, 2014 Cambridge, UK Kanat Kyrgyzbaev, M. Terock, University
More informationHVAC Clinic. Duct Design
HVAC Clinic Duct Design Table Of Contents Introduction... 3 Fundamentals Of Duct Design... 3 Pressure Changes In A System... 8 Example 1... 13 Duct Design Methods... 15 Example 2... 15 Introduction The
More informationStudy of air curtains used to restrict infiltration into refrigerated rooms
Study of air curtains used to restrict infiltration into refrigerated rooms Gregory Verhaeghe 1, Marnix Van Belleghem 1, Arnout Willockx 1, Ivan Verhaert 1, Michel De Paepe 1 1 Ghent University, Department
More informationLOW E SATINÉ 5500 LOW E
SCREEN LOW E INTELLIGENT FABRICS FOR SOLAR PROTECTION Width: 240 cm www.mermet.co.uk LOW E THERMAL SHIELD FOR INTERNAL BLINDS 76% OF SOLAR REFLECTANCE 17% EMISSIVITY for thermal comfort all year round
More informationMASSACHUSETTS INSTITUTE OF TECHNOLOGY DEPARTMENT OF MECHANICAL ENGINEERING Thermal-Fluids Engineering I
MASSACHUSETTS INSTITUTE OF TECHNOLOGY DEPARTMENT OF MECHANICAL ENGINEERING 2.005 Thermal-Fluids Engineering I PROBLEM SET #8, Fall Term 2008 Issued: Thursday, October 23, 2008 Due: Thursday, October 30,
More informationContact, Overview, Index. Guideline heating and cooling. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett.
& S Contact, Overview, Index Guideline heating and cooling Plexus Professor Pilot Architect & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium H & C /Loggia Regula Drypac Lighting TEKNOsim
More informationIntroduction to Heat and Mass Transfer. Week 7
Introduction to Heat and Mass Transfer Week 7 Example Solution Technique Using either finite difference method or finite volume method, we end up with a set of simultaneous algebraic equations in terms
More informationFIXED ROUND CEILING DIFFUSERS & GRILLES APPLICATION
SH.RDI.F1 SH.RDI.F FIXED ROUND CEILING DIFFUSERS & GRILLES APPLICATION SH.RDI.F Shahrokhi fixed round ceiling diffusers & grilles are designed to suit H.V.A.C applications for ceiling mounting or exposed
More informationAir distribution systems. Adjustable radial outlet RA-V...
Air distribution systems Adjustable radial outlet RA-V... DS E 0.2013 Construction design Preliminary remarks KRANTZ KOMPONENTEN has developed its wellknown, successful radial outlet into an adjustable
More informationThermal Imaging Best Practices: The Measuring Object. Page 2
White Thermal Paper Imaging Headline: Best Practices: Subhead The Measuring Goes Object Here Prepared by: Doug Goodwin Market Manager - HVAC Testo, Inc. June 2011 1 Introduction In times of rising energy
More informationLECTURE-11 FAN AND DUCT SYSTEM-2
L ecturer: -D D r. E sam M ejbil A bid Subject: A ir Conditioning and R efrigeration Year: Y Fourth B.Sc. D E P A R TM E N O F M E CH A N ICA L E N G IN E E R IN B abylon U niversity College of E ngineering
More informationLinear diffuser. Description
A C B + D Description is a rectangular linear diffuser in aluminium. is suitable for both supply and exhaust air. is equipped with air guide baffles, making it possible to use for horizontal supply air.
More informationPrinciples of Food and Bioprocess Engineering (FS 231) Problems on Heat Transfer
Principles of Food and Bioprocess Engineering (FS 1) Problems on Heat Transfer 1. What is the thermal conductivity of a material 8 cm thick if the temperature at one end of the product is 0 C and the temperature
More informationGCSE 0237/02 SCIENCE HIGHER TIER PHYSICS 1
Surname Centre Number Candidate Number Other Names 0 GCSE 0237/02 SCIENCE HIGHER TIER PHYSICS 1 P.M. FRIDAY, 15 June 2012 45 minutes ADDITIONAL MATERIALS For s use Question Maximum Mark 1. 5 2. 5 3. 8
More informationCeiling Diffuser. Type ADLR with circular face. Type ADLR-Q with square face 2/16/EN/8
2/16/EN/8 Ceiling Diffuser Type ADLR with circular face Type ADLR-Q with square face TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn
More informationreflect sunlight outdoors Serge 600 ARCHITECTS SELECTION GLASSFIBRE OF = 5%
reflect sunlight outdoors ARCHITECTS SELECTION OF = 5% new collection innovation creativityreflect sunlight outdoors For several years now, Copaco has been ranked among the top players in the sun protection
More information*These are the vinyl for MAX Bepop Cutting/printing machines. We have 100mm (4in) and 200mm(8in) width models available in North America.
The English translation of Bepop standard vinyl (indoor use) technical datasheet 100mm (4in) / 200mm (8in) width Color 100mm(4in) width 200mm(8in) width Black SL-S111N Black SL-S201N Black White SL-S112N
More informationI-FORCE Ironless linear motors
I-FORCE Ironless linear motors Parker Trilogy s I-Force ironless linear motors offer high forces and rapid accelerations in a compact package. With forces ranging from 5.5 lbf (24.5 N) - 197.5 lbf (878.6
More informationDuct Design and Air Distribution Systems
Duct Design and Air Distribution Systems Introduction The chief requirements of an air conditioning duct system are: It should convey specified rates of air flow to prescribed locations It should be economical
More informationCLUSTERLITE CONTENTS MEGAMAN
CONTENTS Specifications for... 2.1 Maximum Temperature Declaration... 2.3 Lumen Maintenance Curve... 2.4 Vs. Temperature... 2.6 Run-up Time... 2.8 Specifications for Power Supply... 2.1 Line Drawings for
More informationExperiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar
Experiment 1 Measurement of Thermal Conductivity of a Metal (Brass) Bar Introduction: Thermal conductivity is a measure of the ability of a substance to conduct heat, determined by the rate of heat flow
More informationAIR TECH SYSTEMS. Technical Brochure. LTG Air Diffusers. Linear air diffusers LDB. Installation in ceilings, walls and sills
AIR TECH SYSTEMS Technical Brochure LTG Air Diffusers Linear air diffusers Installation in ceilings, walls and sills Technicalbrochure Linear air diffusers LTG Comfort Air Technology Air-Water Systems
More informationThe First Law of Thermodynamics. By: Yidnekachew Messele
The First Law of Thermodynamics By: Yidnekachew Messele It is the law that relates the various forms of energies for system of different types. It is simply the expression of the conservation of energy
More informationTREES Training for Renovated Energy Efficient Social housing
TREES Training for Renovated Energy Efficient Social housing Intelligent Energy -Europe programme, contract n EIE/05/110/SI2.420021 Section 2 Tools 2.1 Simplified heating load calculation Tamas CSOKNYAI
More information42C/V. Fan Coil Unit 42C/V
2/V Fan oil Unit 2/V arrier makes the world a better place to live by creating a comfortable, productive and healthy environment regardless of climate. It is our mission is to be customer s first choice
More information