WALL MOUNT HEATER PACKAGES REPLACEMENT PARTS MANUAL. General Notes. Contents. Important

Size: px
Start display at page:

Download "WALL MOUNT HEATER PACKAGES REPLACEMENT PARTS MANUAL. General Notes. Contents. Important"

Transcription

1 REPLACEMENT PARTS MANUAL WALL MOUNT HEATER PACKAGES MODELS: EHWH30-A05, EHWH36-A05, EHWH30-A10, EHWH36-A10, EHWH36-A15, EHWH03-B06, EHWH03-B09, EHWH36-B15, EHWC03A-C06, EHWC03A-C09, EHWH03A-C15, EHWH36TA10, EHWH30TA10, EHWH26-A05, EHWH31-A05, EHWH31-A08, EHWH31-B06, EHWH31-C06 EHWH26-C06, EHSH31-A04, EHSH31-A08, EHSH31-B06, EHSH31-C06 EHWA03-A05, EHWA03-A08, EHWA03-A10, EHWA03-A15, EHWA03-B06, EHWA03-B09, EHWA03-B15, EHWA03A-C12, EHWA03A-C15, EHWA03-E12, EHWA03A-F12, EHWA03TA10, EHWA37-B15 General Notes Contents Ø Revised and/or additional pages may be issued from time to time. Description Page Ø A complete and current manual consists of pages shown in the following contents section. Heater Packages / Heat Pump w Exploded View... 1 w Usage List... 2 w Usage List... 3 w Blank Page... 4 Important Ø Contact the installing and/or local Bard distributor for all parts requirements. Make sure you have the complete model and serial number available from the unit rating plates. Heater Packages / Air Conditioner w Exploded View... 5 w Usage List... 6 BARD MANUFACTURING COMPANY Bryan, Ohio Since Moving ahead, just as planned. Manual: F Supersedes: E File: Tab 18 Date: Page

2 HEATER PACKAGES HEAT PUMP SEXP-165 Page 1

3 HEATER PACKAGES HEAT PUMP EHWH26-A05 Drawing No. Part No. Description Heat Strip 5 KW X X X X Heat Strip 10 KW X X Heat Strip 15 KW X Heat Strip 6 KW X X X Heat Strip 9 KW X X Heat Strip 6 KW X Heat Strip 8 KW 16 GA X 2 127X210 Heater Control Base X X X X X X X X X X X Heater Control Base X X Limit Control X X Limit Control X X X X Limit Control X Limit Control X Limit Control X X X X Limit Control X Thermal Cutoff X X Thermal Cutoff Thermal Cutoff Thermal Cutoff X X Back-up Limit Circuit Breaker 30A X X Circuit Breaker 50A X X X Circuit Breaker 60A X X X Circuit Breaker 40A X X Circuit Breaker 50A X X Circuit Breaker 35A X Circuit Breaker 45A X Circuit Breaker 20A X Heat Contactor Heat Contactor Jumper Bar X X X X Ground Terminal X X X X Jumper Bar Cover X X X X Emergency Heat Relay X X NS Wiring Diagram X X X X NS Wiring Diagram X X NS Wiring Diagram X NS Wiring Diagram X NS Wiring Diagram X X X NS Wiring Diagram X NS Wiring Diagram X EHWH31-A05 EHWH31-A08 EHWH31-B06 EHWH31-C06 EHWH30-A05 EHWH36-A05 EHWH30-A10 EHWH36-A10 EHWH36-A15 EHWH03-B06 EHWH03-B09 EHWH36-B15 NS = Not Shown Page 2

4 HEATER PACKAGES HEAT PUMP Drawing No. Part No. Description Heat Strip 5 KW X X Heat Strip 6 KW X X X X Heat Strip 9 KW X X Heat Strip 6 KW 19.5 GA X Heat Strip 4 KW 16.0 GA X Heat Strip 8 KW 16.0 GA X 2 127X210 Heater Control Base X X X X X Heater Control Base X X X X X Limit Control X X X X Limit Control X Limit Control X Limit Control X Limit Control X Limit Control X Limit Control X Thermal Cutoff Thermal Cutoff Back-up Limit Back-up Limit Disconnect Switch X X X X X Circuit Breaker 30A X X Circuit Breaker 50A X X Circuit Breaker 60A X Circuit Breaker 40A X Circuit Breaker 45A X Heat Contactor Heat Contactor Jumper Bar X X Ground Terminal X X Jumper Bar Cover X X Emergency Heat Relay X X NS Wiring Diagram X NS Wiring Diagram X X NS Wiring Diagram X NS Wiring Diagram X X X X NS Wiring Diagram X NS Wiring Diagram X EHWC03A-C06 EHWC03A-C09 EHWC03A-C15 EHWH30TA10 EHWH36TA10 EHWH26-C06 EHSH31-A04 EHSH31-A08 EHSH31-B06 EHSH31-C06 Page 3

5 This page has been left blank intentionally. Page 4

6 HEATER PACKAGES AIR CONDITIONER SEXP-164 Page 5

7 HEATER PACKAGES AIR CONDITIONER EHWA03-A05 Drawing No. Part No. Description Heat Strip 5 KW X Heat Strip 8 KW X Heat Strip 10 KW X X Heat Strip 15 KW X X X Heat Strip 12 KW X Heat Strip 6 KW X Heat Strip 9 KW X Heat Strip 6 KW 2 X X Heat Strip 9 KW X X 2 127X210 Heater Control Base X X X X X X X X X X Heater Control Base X X X Limit Control X Limit Control X X X X X Limit Control X Limit Control X X X X X X Thermal Cutoff X Thermal Cutoff Thermal Cutoff Back-up Limit Disconnect Switch X X X Circuit Breaker 30A X Circuit Breaker 35A X Circuit Breaker 50A X Circuit Breaker 60A X X Circuit Breaker 25A, 3PH X Circuit Breaker 35A, 3PH X Circuit Breaker 40A, 3PH X Circuit Breaker 50A, 3PH X Circuit Breaker 60A, 3PH X Heat Contactor X X X 2 X X 2 2 X Heat Contactor Jumper Bar X X Ground Terminal X X Jumper Bar Cover X X NS Wiring Diagram X NS Wiring Diagram X X X NS Wiring Diagram X NS Wiring Diagram X X NS Wiring Diagram X X X NS Wiring Diagram X X X EHWA03-A08 EHWA03-A10 EHWA03-A15 EHWA03-B06 EHWA03-B09 EHWA03-B15 EHWA03A-C12 EHWA03A-C15 EHWA03-E12 EHWA03A-F12 EHWA03TA10 EHWA37-B15 NS = Not Shown Page 6

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E

More information

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012 Replacement Parts List No. 055231000 Revision C 04/2012 Singer Incremental Comfort Systems K, EK 07-15 Vintage F Last Manufactured: 1976 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons Series Multi-Position, Internal TXV Multi-Speed ECM Based Air Handler ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data... Heat

More information

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS Time base: 60 Hz (3-wire system) Quartz (2-wire system) Power input: 85 135 VAC / 60 Hz 7 28 VAC / 60 Hz Current consumption:

More information

EXEMPLAR NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 ( ) (X-Paper) 09:00 12:00

EXEMPLAR NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 ( ) (X-Paper) 09:00 12:00 NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 2008 (12041002) (X-Paper) 09:00 12:00 EXEMPLAR This question paper consists of 7 pages. EXEMPLAR -2- NC(V) TIME: 3 HOURS

More information

4.4 E 60/E 100 ELECTRIC ACTUATORS E 60/E 100 TECHNICAL DATA E 60 GENERAL APPLICATIONS E 100 FEATURES. Valve interface: EN ISO 5211

4.4 E 60/E 100 ELECTRIC ACTUATORS E 60/E 100 TECHNICAL DATA E 60 GENERAL APPLICATIONS E 100 FEATURES. Valve interface: EN ISO 5211 ELETRI ATATORS E 0/E 0 TEIAL DATA Valve interface: E ISO Type E 0 A ) E 0 A ) * Operating time (0 0 ) ominal torque ominal current Starting current s 0 m 0, A A s 0 m 0, A 0, A s 0 m A A s 00 m A A s 00

More information

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator

More information

TeSys enclosed starters 2

TeSys enclosed starters 2 Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,

More information

GB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY

GB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY TECHNICAL SPECIFICATIONS GB5BM Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The GB5BM Series of air handlers, when combined with our heat pump or air conditioner,

More information

440V 500V V / / /2 12.

440V 500V V / / /2 12. -26 Manual Motor Protectors March 0 B-Frame D-Frame Table -6. XTPR Rotary Manual Motor Protectors with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective

More information

McQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017

McQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017 Replacement s List No. 055206700 Revision B 02/2017 McQuay Water Source Heat Pump VF, VG, VP 240-390 Vintage E, F, G Last Manufactured: 1992 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

REPAIR PARTS. GPH13 "M" Series Horizontal Package Heat Pumps GPH1324M41AA GPH1330M41AA GPH1336M41AA GPH1342M41AA GPH1348M41AA GPH1360M41AA

REPAIR PARTS. GPH13 M Series Horizontal Package Heat Pumps GPH1324M41AA GPH1330M41AA GPH1336M41AA GPH1342M41AA GPH1348M41AA GPH1360M41AA REPAIR PARTS GPH13 "M" Series Horizontal Package Heat Pumps GPH1324MAA GPH1330MAA GPH1336MAA GPH1342MAA GPH1348MAA GPH1360MAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing

More information

REPAIR PARTS. GPH13 "H" Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB

REPAIR PARTS. GPH13 H Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB REPAIR PARTS GPH13 "H" Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB This manual is to be used by qualified technicians only. 2010 Goodman Manufacturing

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 055204800 Revision B 01/2017 McQuay Climate Control Singer Vertical Water Source Heat Pump FC, FG, FW 240, 330, 400, 500 Vintages C, D Last Manufactured: 1986 To find your Daikin

More information

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product. Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure

More information

H i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f

H i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f H i g h A m p e r a g e 2 5 t o 3 0 0 A M P T y p e I & I I I V e h i c l e P r o t e c t i o n I P 6 7 W a t e r p r o o f I g n i t i o n - P r o t e c t e d S A E & A B Y C C o m p l i a n t L E D T

More information

Switch. R 5 V Capacitor. ower upply. Voltmete. Goals. Introduction

Switch. R 5 V Capacitor. ower upply. Voltmete. Goals. Introduction Switch Lab 6. Circuits ower upply Goals + + R 5 V Capacitor V To appreciate the capacitor as a charge storage device. To measure the voltage across a capacitor as it discharges through a resistor, and

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size

More information

Switch. R 5 V Capacitor. ower upply. Voltmete. Goals. Introduction

Switch. R 5 V Capacitor. ower upply. Voltmete. Goals. Introduction Switch Lab 6. Circuits ower upply Goals + + R 5 V Capacitor V To appreciate the capacitor as a charge storage device. To measure the voltage across a capacitor as it discharges through a resistor, and

More information

Cat. No. 140M-F M-D8E-B

Cat. No. 140M-F M-D8E-B Bulletin 0M Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class Rated Operational

More information

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( ) Installation Instructions: Wall-Mount Dewpoint Probe (809-2011) The HMW90 Wall-Mount Dewpoint Probe (P/N 809-2011) HMW90 measures dewpoint for indoor applications such as anti-sweat heater control and

More information

Installation Contactors ISU-xxx ISM-xxx

Installation Contactors ISU-xxx ISM-xxx Installation Contactors ISU-xxx ISM-xxx Installation contactors are used in building technology switching cabinets of apartment blocks, office buildings, restaurants and hotels, shopping centres and hospitals

More information

Parts Manual R410A Models

Parts Manual R410A Models Parts Manual R410A Models PTAC - PD Series (Electronic Controls) Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps PTAC PARTS E (1-2010) Table of Contents Unit Identification... 2 PTAC System

More information

Performance. Standards. Technical data

Performance. Standards. Technical data ilos Loadbreak disconnectors for INrail and wall mounting ilos up to ilos 2 up to los up to Order codes pplications pprovals / Marking ddon devices Performance INrail type and wall mounting type Main disconnector,

More information

General characteristics, Products

General characteristics, Products The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload

More information

NAME: BATTERY IS TURNED ON TO +1.5 V. BATTERY IS TURNED ON TO -1.5 V.

NAME: BATTERY IS TURNED ON TO +1.5 V. BATTERY IS TURNED ON TO -1.5 V. AP PHYSICS 2 LAB: CAPACITANCE NAME: Google: Phet capacitor lab PART I CAPACITOR Go to the tab Dielectric Increase the plate area to 4. mm 2. Make sure the offset of the dielectric is. mm. Make sure the

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

B6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

B6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS B6VMAX Series Air Handler with TXV 13-19 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) R-410A Refrigerant The B6VMAX Series of air handlers, when combined

More information

Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C

Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C Melton Series Owners Manual Lab Centrifuge Model # s A-4-115-C, A-4-220-C, B-4-115-C, B-4-220-C, C-4-115-C, C-4-220-C, D-4-115-C, D-4-220-C Serial Numbers 85500 & Above NOTICE Wire this centrifuge according

More information

McQuay Climate Control. Water Source Heat Pump Horizontal. CC, CG, CW Vintage C, D. Last Manufactured: 1984

McQuay Climate Control. Water Source Heat Pump Horizontal. CC, CG, CW Vintage C, D. Last Manufactured: 1984 Replacement Parts List No. 055204000 Revision C 01/2017 McQuay Climate Control Water Source Heat Pump Horizontal CC, CG, CW 260-330 Vintage C, D Last Manufactured: 1984 To find your Daikin Applied parts

More information

THIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB.

THIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB. -. September, 9 II DIMS gas-fired, power vented and separated combustion unit heaters for models HD/HDB, HDS/HD, PS/BS, P I. Fuel supply shall be shut-off and the electrical power disconnected before proceeding

More information

nufacturing Company, L.P San Felipe, Suite 500

nufacturing Company, L.P San Felipe, Suite 500 REPAIR PARTS AWUF Vertical Mount Air Handlers AWUF18051AA AWUF18051BA AWUF180516AA AWUF18081AA AWUF18081BA AWUF180816AA AWUF24051AA AWUF24051BA AWUF240516AA AWUF24081AA AWUF24081BA AWUF240816AA AWUF201AA

More information

Lab 5. Current Balance

Lab 5. Current Balance Lab 5. Current Balance Goals To explore and verify the right-hand rule governing the force on a current-carrying wire immersed in a magnetic field. To determine how the force on a current-carrying wire

More information

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION Effective: January 2004 Supersedes, dated June 1998 APPLICATION QUALITY FEATURES Descriptive Bulletin 41-078INTL Flexitest Switch Assemblies Type The type FT-19R (standard length) and FT-19RX (extended

More information

QTi DALI-T/E 2X18 42/ DIM

QTi DALI-T/E 2X18 42/ DIM QTi DALI-T/E 2X18 42/220 240 DIM QUICKTRONIC INTELLIGENT DALI DIM CFL ECG dimmable DALI for CFL Suitable for emergency light installations Product benefits Easy change of defect ECG thanks to available

More information

REPAIR PARTS. ARUF Aluminum Coil Air Handler

REPAIR PARTS. ARUF Aluminum Coil Air Handler REPAIR PARTS ARUF Aluminum Coil Air Handler ARUF172916CA ARUF186CA ARUF193116CA ARUF303016CA ARUF363616CA ARUF364216CA ARUF374316CA ARUF486016CA ARUF496116CA This manual is to be used by qualified technicians

More information

Emergency lighting units EM Inverter

Emergency lighting units EM Inverter T T TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM G, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps ow-profile casing

More information

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Investigation reply tool operation manual

Investigation reply tool operation manual CITIZEN ELECTRONICS CO.,LTD GreenSurveyTool Ver.2.00 Investigation reply tool operation manual May, 2011 CITIZEN ELECTRONICS CO., LTD. Contents 1.Purpose... 2 2.Survey Scope... 2 3.Survey Items... 3 4.Notes

More information

Lab #15: Introduction to Computer Aided Design

Lab #15: Introduction to Computer Aided Design Lab #15: Introduction to Computer Aided Design Revision: 02 Nov 2016 Print Name: Section: GETTING FAMILIAR WITH YOUR BASYS3 DIGILAB BOARD. Problem 1: (26 points) Visually inspect the Digilab board, enter

More information

Installation Instructions

Installation Instructions PACKAGE CONTENTS ITEM QUANTITY Enthalpy Sensor (Part No. HH57AC078) No. 6B, 3 4-in. long Sheet Metal Screw 2 Blue Wire Assembly (256-in. long with 4-in. quick-connect fitting)* Violet Wire Assembly (256-in.

More information

Revision checklist SP10. SP10 Electricity and Circuits. SP10a Electric circuits. SP10b Current and potential difference

Revision checklist SP10. SP10 Electricity and Circuits. SP10a Electric circuits. SP10b Current and potential difference Electricity and Circuits a Electric circuits Describe the basic structure of an atom (positions, relative masses and relative charges of protons, neutrons and electrons). Recognise the circuit symbols

More information

Application of Physics II for. Final Exam

Application of Physics II for. Final Exam Application of Physics II for Final Exam Question 1 Four resistors are connected as shown in Figure. (A)Find the equivalent resistance between points a and c. (B)What is the current in each resistor if

More information

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintages C, D. TYA, TAA Vintages A, B. Last Manufactured: 1999

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintages C, D. TYA, TAA Vintages A, B. Last Manufactured: 1999 Replacement Parts List No. 055233900 Revision D 08/2017 McQuay Climate Control Singer Incremental NE, NH, NR 07-18 Vintages C, D TYA, TAA 007-015 Vintages A, B Last Manufactured: 1999 To find your Daikin

More information

REPAIR PARTS 14 SEER DUEL FUEL PACKAGE MODELS

REPAIR PARTS 14 SEER DUEL FUEL PACKAGE MODELS 14 SEER DUEL FUEL PACKAGE MODELS APD1424070M41AA APD1430090M41AA APD1436090M41AA APD14425M41AA APD14485M41AA GPD1424070M41AA GPD1430090M41AA GPD1436090M41AA GPD14425M41AA GPD14485M41AA REPAIR PARTS This

More information

NR2 Thermal Overload Relay

NR2 Thermal Overload Relay Contactors,, Starters. Type designation N - Current class Design sequence No. N Thermal Overload elay. General. Certificates: CE, KEM, UkrSEPO, GOST, CC, UL;. Electric ratings: C 0/0z, 90V, 0.~30;.3 Tripping

More information

Secured Series Front End Reader Installation Instructions Proximity Reader (ProxPro, ProxPro w/keypad, MiniPro, Thinline II)

Secured Series Front End Reader Installation Instructions Proximity Reader (ProxPro, ProxPro w/keypad, MiniPro, Thinline II) Secured Series Front End Reader Installation Instructions Proximity Reader (ProxPro, ProxPro w/keypad, MiniPro, Thinline II) Installation Procedure: Step 1: Check the Packing List Step 2: Mount the Proximity

More information

Parts List, Wiring Diagrams

Parts List, Wiring Diagrams Parts List, Wiring Diagrams PAE180-300 SERIES PACKAGE AIR CONDITIONER UNITS TABLE OF CONTENTS PARTS LIST----------- 2-11 PARTS DRAWING----- 12-34 WIRING DIAGRAMS--- 35-48 Printed in U.S.A. 7/28/08 KEY

More information

SIRCOVER Manual transfer switches from 125 to 3200 A

SIRCOVER Manual transfer switches from 125 to 3200 A Manual transfer switches svr_149_a 3200 A Function are manual multipolar transfer switches with positive break indication. The family includes two ranges: AC for dead time switching (I-0-II), for overlapping

More information

Designing Information Devices and Systems I Fall 2018 Homework 7

Designing Information Devices and Systems I Fall 2018 Homework 7 Last Updated: 2018-10-05 20:54 1 EECS 16A Designing Information Devices and Systems I Fall 2018 omework 7 This homework is due October 12, 2018, at 23:59. Self-grades are due October 16, 2018, at 23:59.

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

NR2 Thermal Overload Relay. 4. Technical Data. 1. General. 2. Type Designation. 3. Features. Item Series No. I/In Operating time Tp Test condition

NR2 Thermal Overload Relay. 4. Technical Data. 1. General. 2. Type Designation. 3. Features. Item Series No. I/In Operating time Tp Test condition s elays C US N Thermal Overload elay. General. Certificates: CB,CE, UL, PCT, CC, VDE;. Electric ratings: C 0/0z, V, 0.~;.3 Tripping class: 0;. Mounting version: a. Plug-in: vailable for N-.,, 3, 93, 0;

More information

Designing a Thermostat Worksheet

Designing a Thermostat Worksheet Designing a Thermostat Worksheet Most of us have a thermostat in our homes to control heating and cooling systems of our home. These important devices help us save energy by automatically turning off energy

More information

10 N acts on a charge in an electric field of strength 250 N.C What is the value of the charge?

10 N acts on a charge in an electric field of strength 250 N.C What is the value of the charge? Year 11 Physics Electrical Energy in the Home Name: 1. Draw the electric field lines around a) a single positive charge b) between two opposite charged bodies c) two parallel plates + + + + + + + - - -

More information

REPAIR PARTS. GPC15 Horizontal Package Cooling Units

REPAIR PARTS. GPC15 Horizontal Package Cooling Units REPAIR PARTS GPC15 Horizontal Package Cooling Units GPC1524H41AA GPC1524H41AB GPC1530H41AA GPC1530H41AB GPC1536H41AA GPC1536H41AB GPC1542H41AA GPC1542H41AB GPC1548H41AA GPC1548H41AB GPC1560H41AA GPC1560H41AB

More information

REPAIR PARTS. *PD14 Dual Fuel Package Units

REPAIR PARTS. *PD14 Dual Fuel Package Units *PD14 Dual Fuel Package Units APD1424070M41AA APD1424070M41BA APD1430090M41AA APD1430090M41BA APD1436090M41AA APD1436090M41BA APD1437090M41AA APD14425M41AA APD14425M41BA APD14485M41AA APD14485M41BA GPD1424070M41AA

More information

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics 0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

Commercial Generator Parts Catalog. PROTEC Series

Commercial Generator Parts Catalog. PROTEC Series Commercial Generator Parts Catalog PROTEC Series YD ÁÁ ÁÁ To avoid errors or delay in filling your parts order, always give the MODEL, SPEC NO. and SERIAL NO. from the Onan nameplate. For handy reference,

More information

Physics 24 Exam 2 March 18, 2014

Physics 24 Exam 2 March 18, 2014 Exam Total / 200 Physics 24 Exam 2 March 18, 2014 Printed Name: Rec. Sec. Letter: Five multiple choice questions, 8 points each. Choose the best or most nearly correct answer. 1. You need to store electrical

More information

REPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA

REPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA REPAIR PARTS GPH14 H-SERIES R-0A Package Heat Pumps GPH1424HAA GPH1430HAA GPH1436HAA GPH1442HAA GPH1448HAA GPH1460HAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing

More information

UNIT G485 Module Capacitors PRACTICE QUESTIONS (4)

UNIT G485 Module Capacitors PRACTICE QUESTIONS (4) UNIT G485 Module 2 5.2.1 Capacitors PRACTICE QUESTIONS (4) 1 A 2200 µf capacitor is charged to a p.d. of 9.0 V and then discharged through a 100 kω resistor. (a) Calculate : (i) The initial charge stored

More information

PARTS CATALOG MUZ-FE09NA MUZ-FE09NA - 1 MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBB543 REVISED EDITION-C.

PARTS CATALOG MUZ-FE09NA MUZ-FE09NA - 1 MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBB543 REVISED EDITION-C. SPLIT-TYPE AIR CONDITIONERS Revision C: H and FE12NAH have been added. Please void OBB543 REVISED EDITION-B. OUTDOOR UNIT PARTS CATALOG No. OBB543 REVISED EDITION-C Models - 1 H FE12NA FE12NA1 FE12NAH

More information

CHV Series Vector Control Inverter Options. Operating Instructions for Tension Control Card

CHV Series Vector Control Inverter Options. Operating Instructions for Tension Control Card CHV Series Vector Control Inverter Options Operating Instructions for Control Card 1. Model and Specifications 1.1 Model The model of tension card is CHV00ZL. CHV series inverter can conduct constant

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

Section 1 Electric Charge and Force

Section 1 Electric Charge and Force CHAPTER OUTLINE Section 1 Electric Charge and Force Key Idea questions > What are the different kinds of electric charge? > How do materials become charged when rubbed together? > What force is responsible

More information

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details) Staco Energy Products Co. has been a leading manufacturer of variable transformers for over 60 years, building standard as well as custom-designed products for industrial, commercial and military applications.

More information

Switch. R 5 V Capacitor. ower upply. Voltmete. Goals. Introduction

Switch. R 5 V Capacitor. ower upply. Voltmete. Goals. Introduction Switch Lab 9. Circuits ower upply Goals + + R 5 V Capacitor V To appreciate the capacitor as a charge storage device. To measure the voltage across a capacitor as it discharges through a resistor, and

More information

1) Two lightbulbs, one rated 30 W at 120 V and another rated 40 W at 120 V, are arranged in two different circuits.

1) Two lightbulbs, one rated 30 W at 120 V and another rated 40 W at 120 V, are arranged in two different circuits. 1) Two lightbulbs, one rated 30 W at 120 V and another rated 40 W at 120 V, are arranged in two different circuits. a. The two bulbs are first connected in parallel to a 120 V source. i. Determine the

More information

Electricity Test Review

Electricity Test Review Electricity Test Review Definitions; Series Circuit, Parallel Circuit, Equivalent Resistance, Fuse, Circuit Breaker, kilowatt hour, load, short circuit, dry cell, wet cell, fuel cells, solar cells, fossil

More information

Chapter 16: DC Circuits

Chapter 16: DC Circuits Chapter 16: DC Circuits Why might all the electrical devices in your house suddenly turn off if you simultaneously turn too many on? How can you use an electric circuit to model the circulatory system?

More information

ME 4/549 Lab Assignment 5: Single Block Experiment Spring 2006 due 1 June 2006

ME 4/549 Lab Assignment 5: Single Block Experiment Spring 2006 due 1 June 2006 ME 4/549 Lab Assignment 5: Single Block Experiment Spring 2006 due 1 June 2006 version May 23, 2006 1 Objective The objective of the laboratory exercise is to measure the convective heat transfer coefficient

More information

VD1 CLC. Small Valves DIN-range with a higher k v -value

VD1 CLC. Small Valves DIN-range with a higher k v -value 0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /

More information

Electrical Circuits. Winchester College Physics. makptb. c D. Common Time man. 3rd year Revision Test

Electrical Circuits. Winchester College Physics. makptb. c D. Common Time man. 3rd year Revision Test Name... Set... Don.... manner~ man makptb Winchester College Physics 3rd year Revision Test Electrical Circuits Common Time 2011 Mark multiple choice answers with a cross (X) using the box below. I A B

More information

Model 33SZ Basic Unit OPTIONAL FILTER RH COIL CONNECTION PRIMARY/ DEDICATED OUTDOOR AIR MULTI-POINT FLOW SENSOR 5 3/4" (146)

Model 33SZ Basic Unit OPTIONAL FILTER RH COIL CONNECTION PRIMARY/ DEDICATED OUTDOOR AIR MULTI-POINT FLOW SENSOR 5 3/4 (146) DESRIPTION: Sensible cooling coil on the induced air inlet handles zone sensible load. Opposite side to controls location. luminum ripple fins (10 PI) and 1/" (13) copper tubes. and of coil connection

More information

Introduction. Upon completion of Basics of Electricity you will be able to: Explain the difference between conductors and insulators

Introduction. Upon completion of Basics of Electricity you will be able to: Explain the difference between conductors and insulators Table of Contents Introduction...2 Electron Theory...4 Conductors, Insulators and Semiconductors...5 Electric Charges...7 Current...9 Voltage...11 Resistance...13 Simple Electric Circuit...15 Ohm s Law...16

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008 Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB41-078 March 2008 FT-19R and FT-19RX FT-19R 3RU with Individual Clear Covers APPLICATION FEATURES The type FT-19R (standard length) and

More information

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES DISTRIBUTION BOARDS FLUSH-MOUNTING DISTRIBUTION BOARDS GWTEST SOFTWARE (see page 322) Complementary system items Ordinary installation - protected flush mounting DISTRIBUTION / JUNCTION Protection devices...

More information

TeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P

TeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P Dimensions GV ME and GV P Dimensions GV ME GV AX GV AD, AM, AN, AU, AS, AX, X Block GV AD, AM, AN Block GV AU, AS, AX GV AE b, X b GV MEpp GV MEpp () Maximum X Electrical clearance 0 mm for Ue y 0 V,,,

More information

Lecture (07) Electric Current and Resistance By: Dr. Ahmed ElShafee Dr. Ahmed ElShafee, ACU : Spring 2015, Physics II

Lecture (07) Electric Current and Resistance By: Dr. Ahmed ElShafee Dr. Ahmed ElShafee, ACU : Spring 2015, Physics II Lecture (07) Electric Current and Resistance By: Dr. Ahmed ElShafee ١ The glow of the thin wire filament of a light bulb is caused by the electric current passing through it. Electric energy is transformed

More information

Installation and Operation Manual. AllSync Plus Wired Clocks

Installation and Operation Manual. AllSync Plus Wired Clocks and Operation Manual AllSync Plus Wired Clocks Part # H004881 Rev. 4 September 2018 Safety Precautions AllSync Plus Clock & Operation Manual Troubleshooting General Operation Introduction Safety Precautions

More information

Capacitive Sensors. Contents

Capacitive Sensors. Contents Contents Capacitive sensors detect the change in capacitance caused by the approach of an object. Their advantage lies in the ability to detect virtually any material, from metals to oils. 4.2 Definitions,

More information

ELECTRIC CURRENTS D R M A R T A S T A S I A K D E P A R T M E N T O F C Y T O B I O L O G Y A N D P R O T E O M I C S

ELECTRIC CURRENTS D R M A R T A S T A S I A K D E P A R T M E N T O F C Y T O B I O L O G Y A N D P R O T E O M I C S ELECTRIC CURRENTS D R M A R T A S T A S I A K D E P A R T M E N T O F C Y T O B I O L O G Y A N D P R O T E O M I C S lecture based on 2016 Pearson Education, Ltd. The Electric Battery Electric Current

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

Trade of Electrician Standards Based Apprenticeship Capacitance Phase 2 Module No. 2.1 Unit No COURSE NOTES

Trade of Electrician Standards Based Apprenticeship Capacitance Phase 2 Module No. 2.1 Unit No COURSE NOTES Trade of Electrician Standards Based Apprenticeship Capacitance Phase 2 Module No. 2.1 Unit No. 2.1.8 COURSE NOTES Certification & Standards Department Created by Gerry Ryan - Galway TC Revision 1 April

More information

DC Circuits. Circuits and Capacitance Worksheet. 10 Ω resistance. second? on the sodium is the same as on an electron, but positive.

DC Circuits. Circuits and Capacitance Worksheet. 10 Ω resistance. second? on the sodium is the same as on an electron, but positive. Circuits and Capacitance Worksheet DC Circuits 1. A current of 1.30 A flows in a wire. How many electrons are flowing past any point in the wire per second? 2. What is the current in amperes if 1200 Na

More information

SION Lateral 3AE6 Vacuum Circuit Breaker with Lateral Operating Mechanism

SION Lateral 3AE6 Vacuum Circuit Breaker with Lateral Operating Mechanism Catalog HG.07 Edition 03/ 07 SION Lateral 3AE Vacuum Circuit Breaker with Lateral Operating Mechanism Medium-Voltage Equipment siemens.com/sion R-HG-3.psd Catalog HG.07 03 / 07 SION 3AE Vacuum Circuit

More information

Chapter 23 Revision problem. While we are waiting, please try problem 14 You have a collection of six 1kOhm resistors.

Chapter 23 Revision problem. While we are waiting, please try problem 14 You have a collection of six 1kOhm resistors. Chapter 23 Revision problem While we are waiting, please try problem 14 You have a collection of six 1kOhm resistors. 1 Electric Circuits Elements of a circuit Circuit topology Kirchhoff s law for voltage

More information

Calculate the potential difference across the 45 Ω resistor

Calculate the potential difference across the 45 Ω resistor Q1.A student set up the electrical circuit shown in the figure below. (a) The ammeter displays a reading of 0.10 A. Calculate the potential difference across the 45 Ω resistor. Potential difference =...

More information

A wide variety of detector switches available for various Digital AV devices. Typical Specifications

A wide variety of detector switches available for various Digital AV devices. Typical Specifications Switch wide variety of detector switches available for various Digital V devices. Typical Specifications Items Rating max. min. Resistive load Contact resistance Initial /fter operating life Operating

More information

HVAC Electrical Wiring Diagrams / Ohm s Law / Sequence of Operation RV

HVAC Electrical Wiring Diagrams / Ohm s Law / Sequence of Operation RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

Product Manual (Revision D) Original Instructions. Speed Switch and Integrated Speed Switch. Installation and Operation Manual

Product Manual (Revision D) Original Instructions. Speed Switch and Integrated Speed Switch. Installation and Operation Manual Product Manual 82310 (Revision D) Original Instructions Speed Switch and Integrated Speed Switch Installation and Operation Manual General Precautions Read this entire manual and all other publications

More information

Chapter 1W Basic Electromagnetic Concepts

Chapter 1W Basic Electromagnetic Concepts Chapter 1W Basic Electromagnetic Concepts 1W Basic Electromagnetic Concepts 1W.1 Examples and Problems on Electric Circuits 1W.2 Examples on Magnetic Concepts This chapter includes additional examples

More information

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008 LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect

More information

EXPLODED DIAGRAM - PARTS VIEW

EXPLODED DIAGRAM - PARTS VIEW Power Supply Sales Model: KSIL018-H216-I 208-230V~ / 1ph / 60Hz EXPLODED DIAGRAM - PARTS VIEW This information is to be used by qualify AC technicians only KSIL1816- Drawing No. D2IL16181301 Above information

More information

I, THERMAL ANALYSIS OF BUS-BAR FOR SWITCH BOARD

I, THERMAL ANALYSIS OF BUS-BAR FOR SWITCH BOARD THERMAL ANALYSIS OF BUS-BAR FOR SWITCH BOARD Krishna Dwivedi*, Kulwant Dhankar**, Smita Ganjare*** & Hemant More**** Assistant Professor, Mechanical Department, LTCOE, Navi Mumbai, Maharashtra Abstract:

More information

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per

More information

Electricity and Magnetism Module 4 Student Guide

Electricity and Magnetism Module 4 Student Guide Electricity and Magnetism Module 4 Student Guide Note: each time you are finished with a circuit we ask that you disconnect all wires, so that the next circuit you investigate starts with a blank slate.

More information