8 th APMP/TCQM GAS CRM Workshop. K. Kato NMIJ, Japan

Size: px
Start display at page:

Download "8 th APMP/TCQM GAS CRM Workshop. K. Kato NMIJ, Japan"

Transcription

1 8 th APMP/TCQM GAS CRM Workshop at NMIJ, Tsukuba, Japan May June 2010 K. Kato NMIJ, Japan 1

2 Participants Total number of participants 52. (17 from overseas and 35 from inside id Japan. China, Chinese Taipei, i Japan, Korea, Malaysia, Russia, Singapore, Thailand) 2

3 Conference room and Poster presentation 3

4 Agenda of 8 th Gas CRM Workshop, 9th -11th, June th June (Wed.): Opening and Oral Sessions 9: :00 00 Registration 10:00 10:05 Opening Kenji Kato, NMIJ 10:05 10:15 Greeting from Director of NMIJ Yukinobu Miki, NMIJ 10:15 10:25 Roll call All 10:25 10:55 Introduction of Gas metrology at NMIJ Kenji Kato, NMIJ 10:55 11:25 Establishing KRISS standard for hydrogen sulfide and its use for international key comparison between NMIs Gwi Suk Heo, KRISS 11:25 11:55 The uncertainty contribution from reaction equilibrium Defa Wang. NIM 11:55 13:25 Lunch (at AIST restaurant 2F) 13:25 13:55 Preparation of Gas Standard d Mixtures Hisam Bin Sumiry, NML-SIRIM 13:55 14:25 Functioning of Quality Management System within Supporting CMCs in Gas Analysis Anna Kolobova and Elena Gromova, VNIIM 14:25 14:55 Preparation PGRM by using NIMT facilities Ratirat Sinweeruthai, NIMT 14:55 15:25 The Preparation and Stability of Stable Low Concentration Standards Ayaka Nishiyama, Air Liquide Lab. 15:25 16:55 Lab tour NMIJ Building :55 17:05 Announcement 4

5 10th June (Thu.): Oral Sessions and Poster Session 9:30 9:40 Opening 9:40 10:10 The result of CCQM-K74 (NO2 10 mmol/mol) Yuya Ota, CERI 10:10 10:40 Certification of high Purity Methane Standard Jin Choon Woo, KRISS 10:40 11:10 Report on coproduction of CH4/air within ACRM Hai Wu. NIM 11:10 11:40 Study for a determination method of property values of hydrocarbons' reference materials using post- column reaction GC-FID system 11:40 12:00 Photo session (at foyer) All 12:00 13:00 Lunch (at foyer) All Takurou Watanabe, NMIJ 13:00 13:30 Prismatic CRDS Jeremiah R.Riddle, Tiger Optics 13:30 14:00 Preparation of Stable Hydrogen Chloride standard Gases at Low concentrations 14:00 14:30 Tea (at foyer) All 14:30 15:30 Poster session (at foyer) All Kanako Nishi, Yusuke Yoshida, Takachiho Chemical Industial. 15:30 16:00 Quality control of the preparation of 1μmol/mol Gas Pan Yi, NIMTT (Cancelled) Reference Materials for Micro-Oxygen in Nitrogen 16:00 16:30 Determination of purity of oxygen by paramagnetic oxygen analyzer Takuya Shimosaka, NMIJ 16:30 17:00 Development of N2O in air standards d for CCQM K-68 Noubuyuki kiaoki, NMIJ 17:00 17:15 Summary and Next meeting Dr. K. Kato, NMIJ 5

6 10th June (Thu.): List of Poster Session at Foyer Poster 1 Poster 2 Poster 3 Canceled Uncertainty Evaluation on Gravimetric Preparation and Concentration Verification of Primary Reference Gas Mixtures Analysis of H 2 in Industrial exhaust gas stream using GC- DID combined with Canister Sampling Lin Tsai-Yin, CMS/ITRI Jui-Hsiang Cheng, CMS/ITRI Evaluation of error sources in a gravimetric technique for Poster 4 preparation of a reference gas mixture (a case of carbon Nobuhiro Matsumoto, NMIJ dioxide in synthetic air) Poster 5 Introduction of CERI Shinji Uehara, CERI Poster 6 Poster 7 An activity of World Calibration Centre for methane and the calibration architecture in JMA Study on the dynamic volumetric method of nitrogen dioxide id standard d gas Noriaki Oshiki, JMA Sang Hyop Oh, KRISS Poster 8 Prismatic CRDS Jeremiah R.Riddle, Tiger Optics Poster 9 Paramagnetic Oxygen Analyzer Hironori Tsujimoto, Japan Air Gases Poster 10 Poster 11 Preparation of Stable Hydrogen Chloride Standard Gases at Low Concentrations Traceability system on ambient ozone measurement in Japan Takachiho Chemicals Shigeru Hashimoto, Hitoshi Mukai, Hiroshi Tanimoto, NIES Poster 12 The Application of FTIR in Fluoride Compound Analysis Liangjing Gai, NIM 6

7 Technical tour to Air Liquide Japan and AIST North center, 11 th June

8 Technical tour to Air Liquide Japan and AIST North center, 11 th June

9 Technical tour to Air Liquide Japan and AIST North center, 11 th June 2010 Top of Mt. Tsukuba Lunch at Japanese restaurant 9

10 Summary 8 th APMP/TCQM GAS CRM Workshop was held at NMIJ, Japan on 9 11 June There were 52 participants from 9 economies (17 from overseas). 15 aural and 12 poster presentations were reported. On 9 th June, participants went to Lab tour in Organic Analytical Division in NMIJ (Gas, organic solution and biomedical). On 11 th June, participants went to technical tour to a gas filling factory of Air Liquide Japan and ultra high volume flow calibration facilities of NMIJ at AIST north center. Welcome and farewell banquets were held on 9 th and 11 th June. Next workshop will be hosted by A*star Singapore in October

11 See you in Singapore! 11

Preparation of nitrous oxide in air standard (320 nmol/mol) for CCQM-K68

Preparation of nitrous oxide in air standard (320 nmol/mol) for CCQM-K68 Preparation of nitrous oxide in air standard (320 nmol/mol) for CCQM-K68 8th APMP/TCQM Gas CRM Workshop June 10 th, 2010 Tukuba, Ibaraki, Japan Nobuyuki Aoki, Takuya Shimosaka, Nobuhiro Matsumoto, Kenji

More information

Preparation of nitrous oxide (N 2 O) in air standard being traceable to SI by gravimetric method

Preparation of nitrous oxide (N 2 O) in air standard being traceable to SI by gravimetric method Preparation of nitrous oxide ( O) in air standard being traceable to SI by gravimetric method 15th WMO Meeting of Experts on Carbon Dioxide, Other Greenhouse Gases, and Related Tracer Measurement Techniques

More information

Chemical Standard Department, 1600, Shimo-Takano, Sugito-machi, Kitakatsushikagun, Saitama , JAPAN

Chemical Standard Department, 1600, Shimo-Takano, Sugito-machi, Kitakatsushikagun, Saitama , JAPAN International Key Comparison APMP.QM-K4.1 Final report 24/10/2007 Kenji Kato 1, Masaaki Maruyama 2, Jin Seog Kim 3, Oh, Sang Hyub 3, Jin-Chun Woo 3, Yongdoo Kim 3, Hyunkil Bae 3, Qiao Han 4, Zeyi Zhou

More information

Preparation Primary Gas Reference Material (PGRM) by using NIMT Facilities

Preparation Primary Gas Reference Material (PGRM) by using NIMT Facilities Preparation Primary Gas Reference Material (PGRM) by using NIMT Facilities By Ms.Ratirat Sinweeruthai June 9-11, 2010 Tsukuba, Japan 8 th APMP/TCQM Gas CRM Workshop Overview Objective of Study EMU of Weighing

More information

Analytical Measurements, 19, Moskovsky Prospekt, St-Petersburg, Russia

Analytical Measurements, 19, Moskovsky Prospekt, St-Petersburg, Russia International Comparison CCQM-K10 Final Report Franklin Guenther 1, George Rhoderick 1, Alain Marschal 2, Anneliese Medem 3, Kenji Kato 4, Gwi Suk Heo 5, Ed de Leer 6, Annarita Baldan 6, Theo L. Hafkenscheid

More information

GMA STATISTICS Countries. Achievements of metrology HRD service for Foreign customers in 2018

GMA STATISTICS Countries. Achievements of metrology HRD service for Foreign customers in 2018 GMA STATISTICS 018 Achievements of metrology HRD service for Foreign customers in 018 70 people from 1 countries have enjoyed opportunities of studying at KRISS. Group courses Individual courses Graduate

More information

Force Key Comparison APMP.M.F-K2.a and APMP.M.F-K2.b (50 kn and 100 kn) Final Report 6 August Pilot: KRISS, Republic of Korea Yon-Kyu Park

Force Key Comparison APMP.M.F-K2.a and APMP.M.F-K2.b (50 kn and 100 kn) Final Report 6 August Pilot: KRISS, Republic of Korea Yon-Kyu Park Force Key Comparison APMP.M.F-K2.a and APMP.M.F-K2.b (50 kn and 100 kn) Final Report 6 August 2018 Pilot: KRISS, Republic of Korea Yon-Kyu Park Muktar Sawi (NMIM) Seif M. Osman (NIS) S.S.K.Titus (NPLI)

More information

Original. Organic Standards Section, Organic Analytical Chemistry Division, National Metrology Institute of Japan (NMIJ),

Original. Organic Standards Section, Organic Analytical Chemistry Division, National Metrology Institute of Japan (NMIJ), Original Development of a Precise Method for the Quantitative Analysis of Hydrocarbons Using Post Column Reaction Capillary Gas Chromatography with Flame Ionization Detection Takuro Watanabe 1,KenjiKato

More information

A preparative comparison using the harmonisation method on standards of synthetic natural gas (CCQM-P87)

A preparative comparison using the harmonisation method on standards of synthetic natural gas (CCQM-P87) NPL REPORT DQL AST 13 A preparative comparison using the harmonisation method on standards of synthetic natural gas (CCQM-P87) G Vargha, M J T Milton, H-J Heine, B Martin, A Pérez, V Serrano, F Rangel,

More information

NPL, India activity related to water as per the need of the country

NPL, India activity related to water as per the need of the country NPL, India activity related to water as per the need of the country, Ph.D. (Sr. Scientist) Chemical & Food BND Group Indian Reference Materials (BND) Division CSIR-National Physical Laboratory, New Delhi,

More information

Application and Validation of a Determination Method Using Post-column Reaction Gas Chromatography of Nitrogen-containing Organic Compounds

Application and Validation of a Determination Method Using Post-column Reaction Gas Chromatography of Nitrogen-containing Organic Compounds ANALYTICAL SCIENCES JULY 2018, VOL. 34 853 2018 The Japan Society for Analytical Chemistry Application and Validation of a Determination Method Using Post-column Reaction Gas Chromatography of Nitrogen-containing

More information

Final Report on the APMP Air Speed Key Comparison (APMP.M.FF-K3)

Final Report on the APMP Air Speed Key Comparison (APMP.M.FF-K3) Final Report on the APMP Air Speed Key Comparison (APMP.M.FF-K3) July, 00 (Revised) Yoshiya Terao, Yong Moon Choi, Mikhail Gutkin 3, Wu Jian 4, Iosif Shinder 5 and Cheng-Tsair Yang 6 NMIJ, AIST, Japan

More information

APMP Key Comparison of DC Voltage at V and 10 V

APMP Key Comparison of DC Voltage at V and 10 V Final Report APMP.EM.BIPM-K11.3 APMP Key Comparison of DC Voltage at 1.018 V and 10 V Kyu-Tae Kim* (Korea Research Institute of Standards and Science, KRISS) Michitaka Maruyama (National Metrology Institute

More information

Rep. of Korea (KRISS), Japan (NMIJ, CERI), Netherlands (NMi), Russia (VNIIM), United Kingdom (NPL), United States of America (NIST)

Rep. of Korea (KRISS), Japan (NMIJ, CERI), Netherlands (NMi), Russia (VNIIM), United Kingdom (NPL), United States of America (NIST) International Key Comparison CCQM-K22 Final Draft Report - 2/10/200 Kenji Kato 1, Masaaki Maruyama 2, Jin Seog Kim, Gwi Suk Heo, Yong-Doo Kim, Franklin Guenther 4, George Rhoderick 4, Adriaan M.H. van

More information

Calibration and Purity Assessment in Chemical Analysis

Calibration and Purity Assessment in Chemical Analysis Better Standards, Better Life! Calibration and Purity Assessment in Chemical Analysis 25 November 2010 Hun-Young So Philosophical question Q: What makes metrology in chemistry so unique? A: Definition

More information

FINAL REPORT ON KEY COMPARISON APMP.AUV.A-K3

FINAL REPORT ON KEY COMPARISON APMP.AUV.A-K3 FINAL REPORT ON KEY COMPARISON APMP.AUV.A-K3 29 November, 2011 Dr. Hyu-Sang Kwon, Dr. Sang-Joon Suh and Jae-Gap Suh Korea Research Institute of Standards and Science (KRISS) Metrologia Tech. Suppl. 49

More information

International Comparison

International Comparison International Comparison Adriaan M.H. van der Veen 1, Hans-Joachim Heine, Freek N.C. Brinkmann 1, Paul R. Ziel 1, Ed W.B. de Leer 1, Wang Lin Zhen 3, Kenji Kato 4, Leonid A. Konopelko 5, Tatjana A. Popova

More information

Particle number concentration standards at NMIJ, including a new calibration service with an inkjet aerosol generator.

Particle number concentration standards at NMIJ, including a new calibration service with an inkjet aerosol generator. Particle number concentration standards at NMIJ, including a new calibration service with an inkjet aerosol generator Hiromu Sakurai hiromu.sakurai@aist.go.jp Particle Measurement Research Group National

More information

Analytical methods for hydrogen fuel QC Thomas Bacquart, Sam Bartlett, Abigail S.O. Morris, Nick Allen, Arul Murugan

Analytical methods for hydrogen fuel QC Thomas Bacquart, Sam Bartlett, Abigail S.O. Morris, Nick Allen, Arul Murugan Analytical methods for hydrogen fuel QC Thomas Bacquart, Sam Bartlett, Abigail S.O. Morris, Nick Allen, Arul Murugan 06-07/06/2017, HYCORA workshop (Trondheim)Laboratory NPL s Gas Metrology Group Analytical

More information

Final Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR

Final Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR Final Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR Jin Wan Chung 1, Shih Mean Lee, Sungjun Lee 1 1 Korea Research Institute of Standards

More information

CCQM-K113 final report. Noble gas mixture

CCQM-K113 final report. Noble gas mixture CCQM-K113 final report Noble gas mixture Jeong Sik Lim 1, Jinbok Lee 1, Dongmin Moon 1, James Tshilongo 1,, Jeongsoon Lee 1, Han Qiao, Hu Shuguo, Zhang Tiqiang, Michael E. Kelley 3, George C. Rhoderick

More information

Natural Resources and Sustainable Development in Surrounding Regions of the Mongolian Plateau

Natural Resources and Sustainable Development in Surrounding Regions of the Mongolian Plateau CALL FOR PAPERS Natural Resources and Sustainable Development in Surrounding Regions of the Mongolian Plateau INTERNATIONAL CONFERENCE SEBTEMBER 12-16, 2008 ULAANBAATAR, MONGOLIA THEMES: Physical geography,

More information

CCQM-P28: An international comparison of ground-level ozone reference standards

CCQM-P28: An international comparison of ground-level ozone reference standards CCQM-P28: An international comparison of ground-level ozone reference standards R.I. Wielgosz, J. Viallon, M. Esler and P. Moussay National and international networks for atmospheric ozone measurements

More information

CCT/10-21 Extrapolation of the ITS-90 down to the boiling point of nitrogen from the triple point of argon

CCT/10-21 Extrapolation of the ITS-90 down to the boiling point of nitrogen from the triple point of argon CCT/10-21 Extrapolation of the ITS-90 down to the boiling point of nitrogen from the triple point of argon Tohru Nakano and Osamu Tamura National Metrology Institute of Japan (NMIJ), AIST Tsukuba, Japan

More information

Introduction. Martin J. T. Milton. Director of the BIPM. Monday 27th June 2016

Introduction. Martin J. T. Milton. Director of the BIPM. Monday 27th June 2016 Introduction Martin J. T. Milton Director of the BIPM Monday 27th June 2016 Bureau International des Poids et Mesures Established in 1875 by the Metre Convention Based in Paris and financed by 57 Member

More information

Second Announcement. 2 nd Workshop CGMS International Cloud Working Group. 29 October - 2 November 2018, Madison, Wisconsin, USA

Second Announcement. 2 nd Workshop CGMS International Cloud Working Group. 29 October - 2 November 2018, Madison, Wisconsin, USA Second Announcement 2 nd Workshop CGMS International Cloud Working Group 29 October - 2 November 2018, Madison, Wisconsin, USA Organized by the Space Science and Engineering Center of the University of

More information

International Standardization for Measurement and Characterization of Nanomaterials

International Standardization for Measurement and Characterization of Nanomaterials 2012/SOM2/SCSC/CON/008 International Standardization for Measurement and Characterization of Nanomaterials Submitted by: Japan 9 th Conference on Standards and Conformance in the Field of Innovations and

More information

Report on APMP Supplementary Comparison High precision roundness measurement APMP.L-S4. Final report

Report on APMP Supplementary Comparison High precision roundness measurement APMP.L-S4. Final report National Institute of Metrology (Thailand) Report on APMP Supplementary Comparison APMP.L-S4 J. Buajarern, National Institute of Metrology (Thailand) (NIMT), Thailand K. Naoi, National Metrology Institute

More information

APMP TCTF Working Group on the Mutual Recognition Agreement

APMP TCTF Working Group on the Mutual Recognition Agreement Asia Pacific Metrology Programme APMP TCTF Working Group on the Mutual Recognition Agreement Louis Marais, NMIA Michael Wouters, NMIA APMP, Beijing, November 2015 Role of the WG MRA Co-ordinate both inter-

More information

APMP.QM-S3 Cd in Rice Powder

APMP.QM-S3 Cd in Rice Powder APMP.QM-S3 Cd in Rice Powder (Coordinated by KRISS, NIM and NMIJ) Final Draft Report Sep. 16, 2011 Yong-Hyeon YIM, Euijin HWANG, Jun WANG, Yanbei ZHU Summary The present study, APMP.QM-S3, was performed

More information

CCQM-K27.2 Second Subsequent Study: Determination of Ethanol in Aqueous Media Final Report

CCQM-K27.2 Second Subsequent Study: Determination of Ethanol in Aqueous Media Final Report CCQM-K27.2 Second Subsequent Study: Determination of Ethanol in Aqueous Media Final Report Michele M. Schantz, Reenie M. Parris, and Willie E. May National Institute of Standards and Technology (NIST)

More information

Report of the key comparison APMP.QM-K19 APMP comparison on ph measurement of borate buffer

Report of the key comparison APMP.QM-K19 APMP comparison on ph measurement of borate buffer Report of the key comparison APMP.QM-K19 APMP comparison on ph measurement of borate buffer (Final Report) Participants: Akiharu Hioki, Toshiaki Asakai, Igor Maksimov, Toshihiro Suzuki and Tsutomu Miura

More information

Requirements of a reference measurement procedure and how they relate to a certified reference material for ctni that is fit for purpose

Requirements of a reference measurement procedure and how they relate to a certified reference material for ctni that is fit for purpose Requirements of a reference measurement procedure and how they relate to a certified reference material for ctni that is fit for purpose David M. Bunk, Ph.D. National Institute of Standards and Technology

More information

CONTENT 2. ORGANIZATION 3. SERVICES. instruments. (3)Activities of RIC Tsukuba

CONTENT 2. ORGANIZATION 3. SERVICES. instruments. (3)Activities of RIC Tsukuba 1 CONTENT 1. INTRODUCTION 2. ORGANIZATION 3. SERVICES (1)Quality assurance of meteorological instruments (2)Research and development (3)Activities of RIC Tsukuba 2 Meteorological Instruments Center (MIC)

More information

Introduction of RIC Tsukuba (Japan, RAII)

Introduction of RIC Tsukuba (Japan, RAII) Introduction of RIC Tsukuba (Japan, RAII) 20 March, 2018 Kouichi NAKASHIMA Scientific Officer Regional Instrument Centre Tsukuba Observing Division, Observing Department Outline 1. Overview of Organization

More information

The BIPM key comparison database, Aug /10

The BIPM key comparison database, Aug /10 BIPM.EM-K11.b, EUROMET.EM.BIPM-K11, APMP.EM.BIPM-K11.1, EUROMET.EM.BIPM-K11.5, EUROMET.EM.BIPM-K11.6, SIM.EM.BIPM-K11.b, COOMET.EM.BIPM-K11, APMP.EM.BIPM-K11.4 and APMP.EM.BIPM-K11.3 Key comparison BIPM.EM-K11.b

More information

Improvement of traceability in the field of mass concentration measurements of particles in aerodisperse media carried out in the Russian Federation

Improvement of traceability in the field of mass concentration measurements of particles in aerodisperse media carried out in the Russian Federation International Bureau of Weights and Measures Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology Working Group on Gas Analysis PARTICULATE WORKSHOP Improvement of traceability

More information

Final Report. APMP.EM-K4.1 APMP Key Comparison of Capacitance at 10 pf

Final Report. APMP.EM-K4.1 APMP Key Comparison of Capacitance at 10 pf Final Report APMP.EM-K4.1 APMP Key Comparison of Capacitance at 10 pf H. L. Johnson National Measurement Institute, Australia February 09 1 Contents 1 Introduction...5 Participants and organisation of

More information

Part 4- Chemistry Paper 1 Bonding Knowledge Questions

Part 4- Chemistry Paper 1 Bonding Knowledge Questions Part 4- Chemistry Paper 1 Bonding Knowledge Questions How bonding and structure are related to the properties of substances A simple model of the atom, symbols, relative atomic mass, electronic charge

More information

Lab i x i u i Lab i x i u i / (mg/kg) / (mg/kg) / (mg/kg) / (mg/kg)

Lab i x i u i Lab i x i u i / (mg/kg) / (mg/kg) / (mg/kg) / (mg/kg) MEASURAND : Mass fraction of total Arsenic in brown rice flour NOMINAL VALUE : 0.05 mg/kg to 0.5 mg/kg MEASURAND : Mass fraction of Cadmium in brown rice flour NOMINAL VALUE : 0.1 mg/kg to 0.5 mg/kg x

More information

Purity Determination of Acetaldehyde in an Acetaldehyde Certified Reference Material

Purity Determination of Acetaldehyde in an Acetaldehyde Certified Reference Material ANALYTICAL SCIENCES JUNE 2015, VOL. 31 463 2015 The Japan Society for Analytical Chemistry Original Papers Purity Determination of Acetaldehyde in an Acetaldehyde Certified Reference Material Taichi YAMAZAKI,

More information

NIST gas standards containing volatile organic compounds in support of ambient air pollution measurements

NIST gas standards containing volatile organic compounds in support of ambient air pollution measurements Air Pollution XVI 357 NIST gas standards containing volatile organic compounds in support of ambient air pollution measurements G. C. Rhoderick Analytical Chemistry Division, Chemical Science and Technology

More information

Improving the accuracy of NO 2 and Ozone monitoring

Improving the accuracy of NO 2 and Ozone monitoring Improving the accuracy of NO 2 and Ozone monitoring J. Viallon, E. Flores, F. Idrees, P. Moussay, and R.I. Wielgosz Standards and Measurements for Clean Air 14 October 2016, IPQ Caparica, Portugal Air

More information

Final Report on Key Comparison APMP.M.P-K7 in Hydraulic Gauge Pressure from 10 MPa to 100 MPa

Final Report on Key Comparison APMP.M.P-K7 in Hydraulic Gauge Pressure from 10 MPa to 100 MPa Version 1.1 of 1 August 5 ASIA-PACIFIC METROLOGY PROGRAMME 1 MPa HYDRAULIC PRESSURE INTERLABORATORY COMPARISON Comparison Identifier: APMP.M.P-K7 Final Report on Key Comparison APMP.M.P-K7 in Hydraulic

More information

4.3.1 Chemical measurements, conservation of mass and the quantitative interpretation of chemical equations

4.3.1 Chemical measurements, conservation of mass and the quantitative interpretation of chemical equations 4.3 Quantitative chemistry Chemists use quantitative analysis to determine the formulae of compounds and the equations for reactions. Given this information, analysts can then use quantitative methods

More information

Key Comparisons, the MRA and CMCs: An International Measurement Infrastructure. Robert Wielgosz. Bureau International des Poids et Mesures

Key Comparisons, the MRA and CMCs: An International Measurement Infrastructure. Robert Wielgosz. Bureau International des Poids et Mesures Key Comparisons, the MRA and CMCs: An International Measurement Infrastructure Robert Wielgosz The task of the BIPM is to ensure world-wide uniformity of measurements and their traceability to the International

More information

Development of plastic certified reference materials (CRMs) to cope with restrictions on hazardous substances

Development of plastic certified reference materials (CRMs) to cope with restrictions on hazardous substances Research paper Development of plastic certified reference materials (CRMs) to cope with restrictions on hazardous substances - CRMs for analysis of heavy metals and brominated flame retardants regulated

More information

Part 6- Chemistry Paper 1 Bonding Application Questions Triple Science

Part 6- Chemistry Paper 1 Bonding Application Questions Triple Science Part 6- Chemistry Paper 1 Bonding Application Questions Triple Science How bonding and structure are related to the properties of substances A simple model of the atom, symbols, relative atomic mass, electronic

More information

THE FUTURE OF SCIENTIFIC METROLOGY. ANDREW WALLARD, DIRECTOR OF THE BIPM. IMEKO, Portugal 2009

THE FUTURE OF SCIENTIFIC METROLOGY. ANDREW WALLARD, DIRECTOR OF THE BIPM. IMEKO, Portugal 2009 THE FUTURE OF SCIENTIFIC METROLOGY. ANDREW WALLARD, DIRECTOR OF THE BIPM. IMEKO, Portugal 2009 SUMMARY Metrology meets a wide range of needs and is always changing. Some of the main issues for the future

More information

APMP supplementary comparison of absorbed dose rate in tissue for beta radiation

APMP supplementary comparison of absorbed dose rate in tissue for beta radiation APMP supplementary comparison of absorbed dose rate in tissue for beta radiation BIPM KCDB: APMP.R(I)-S2 Technical Protocol N. Saito and M. Kato National Metrology Institute of Japan (NMIJ), Tsukuba, Ibaraki

More information

High-pressure qnmr spectroscopy in condensed- and gas-phase towards determination of impurities and compositions of gas mixtures

High-pressure qnmr spectroscopy in condensed- and gas-phase towards determination of impurities and compositions of gas mixtures 13.10.2016 High-pressure qnmr spectroscopy in condensed- and gas-phase towards determination of impurities and compositions of gas mixtures Klas Meyer, Heinrich Kipphardt, Michael Maiwald Online NMR Spectroscopy

More information

The Technologies of Chemical Metrology and Quality Assurance of Measurement Results in Food Analysis

The Technologies of Chemical Metrology and Quality Assurance of Measurement Results in Food Analysis The Technologies of Chemical Metrology and Quality Assurance of Measurement Results in Food Analysis Prof. Li Hongmei National Institute of Metrology, China (NIM, China) National Research Center of Certified

More information

Measurement & Uncertainty - Concept and its application

Measurement & Uncertainty - Concept and its application Measurement & Uncertainty - Concept and its application June. 20 2012 JongOh Choi (choijongoh@kriss.re.kr) I don t know what I don t know. If we don t express what we know in the form of numbers, we really

More information

Matter Properties and Changes

Matter Properties and Changes Matter Properties and Changes What is matter? anything that takes up space (volume) and has mass everything around you is made up of matter matter has 3 main states: solid, liquid, and gas Physical Property

More information

4.3 Quantitative chemistry

4.3 Quantitative chemistry 4.3 Quantitative chemistry Chemists use quantitative analysis to determine the formulae of compounds and the equations for reactions. Given this information, analysts can then use quantitative methods

More information

Status Report of Time and Frequency Activities at NPL- India

Status Report of Time and Frequency Activities at NPL- India Status Report of Time and Frequency Activities at NPL- India (TCTF 2017) Team: V. N. Ojha, Ashish Agarwal, P. Arora, S. Panja, P. Thorat, T. Bharadwaj, S. De, S. Yadav, P. Kandpal, M. P. Olaniya and D

More information

White Paper. Overview: NDIR Definition:

White Paper. Overview: NDIR Definition: Title: NDIR Technology Overview, Compliance, and Comparison to Other Generally Available Gas Measurement Technologies TSN Number: 06 File:\\MII- SRV1\Metron\Bridge_Analyzers\Customer_Service_Documentation\White_Papers\06

More information

The Workshop on Recent Progress in Theoretical and Computational Studies of 2D Materials Program

The Workshop on Recent Progress in Theoretical and Computational Studies of 2D Materials Program The Workshop on Recent Progress in Theoretical and Computational Program December 26-27, 2015 Beijing, China December 26-27, 2015, Beijing, China The Workshop on Recent Progress in Theoretical and Computational

More information

Determination of Minimum Detectable Partial Pressure (MDPP) of QMS and its Uncertainty

Determination of Minimum Detectable Partial Pressure (MDPP) of QMS and its Uncertainty Workshop on Towards more reliable partial and outgassing rate measurements Berlin, Germany, January 30 - February 1, 2017 Determination of Minimum Detectable Partial Pressure (MDPP) of QMS and its Uncertainty

More information

Comparability and Traceability Point of view from a metrological institute

Comparability and Traceability Point of view from a metrological institute Comparability and Traceability Point of view from a metrological institute Ed W.B. de Leer NMi Van Swinden Laboratory Delft, The Netherlands 1 My Discussions in Metrologyland 2 The CCQM in 1996 3 Traceability

More information

Abstract. 1. Introduction

Abstract. 1. Introduction The importance of establishing a very-high temperature radiation thermometry measurement capability at the National Metrology Institute of South Africa (NMISA) Speaker: Dr Efrem K Ejigu National Metrology

More information

Final Report for the APMP.T-K4 (Draft B on October 27, 2011)

Final Report for the APMP.T-K4 (Draft B on October 27, 2011) Final Report for the APMP.T-K4 (Draft B on October 27, 2011) Comparison of Realizations of Aluminum Freezing-Point Temperatures Prepared by K. S. Gam (coordinator) and W. Joung Korea Research Institute

More information

The 19th Japan-Korea-Taiwan Symposium on. Strongly Correlated Electron Systems (JKT19) Jan 11-13, 2019 at Waseda University

The 19th Japan-Korea-Taiwan Symposium on. Strongly Correlated Electron Systems (JKT19) Jan 11-13, 2019 at Waseda University The 19th Japan-Korea-Taiwan Symposium on Strongly Correlated Electron Systems (JKT19) Jan 11-13, 2019 at Waseda University JKT19 Program The first day: Jan 11 (Fri) 9:15-9:30 Opening 9:30-10:30 Session

More information

Determination of Ar molar mass for the Boltzmann constant. Inseok Yang, Jin Bok Lee, Jin Seog Kim Korea Research Institute of Standards and Science

Determination of Ar molar mass for the Boltzmann constant. Inseok Yang, Jin Bok Lee, Jin Seog Kim Korea Research Institute of Standards and Science Determination of molar mass for the Boltzmann constant Inseok Yang, Jin Bok Lee, Jin Seog Kim Korea Research Institute of Standards and Science IPQ, 13 October 2016 Acoustic determination of k and molar

More information

Highlights in the work of the BIPM during 2017

Highlights in the work of the BIPM during 2017 Highlights in the work of the BIPM during 2017 Dr Martin Milton BIPM Director 18 October 2017 BIPM highlights of 2017 01 Introduction to the BIPM 02 Liaison work 03 Laboratory work Physical, Time, Ionising

More information

Part 7- Quantitative Chemistry Application Questions Triple Science

Part 7- Quantitative Chemistry Application Questions Triple Science Part 7- Quantitative Chemistry Application Questions Triple Science How bonding and structure are related to the properties of substances A simple model of the atom, symbols, relative atomic mass, electronic

More information

Final Report on Key Comparison APMP.M.P-K13 in Hydraulic Gauge Pressure from 50 MPa to 500 MPa

Final Report on Key Comparison APMP.M.P-K13 in Hydraulic Gauge Pressure from 50 MPa to 500 MPa ASIA-PACIFIC METROLOGY PROGRAMME 5 MPa HYDRAULIC PRESSURE INTERLABORATORY COMPARISON Comparison Identifier: APMP.M.P-K13 Final Report on Key Comparison APMP.M.P-K13 in Hydraulic Gauge Pressure from 5 MPa

More information

APMP.M.P-K9 (Absolute pressure up to 110 kpa) 21 May, 2013 In-Mook CHOI*, Sam-Yong WOO

APMP.M.P-K9 (Absolute pressure up to 110 kpa) 21 May, 2013 In-Mook CHOI*, Sam-Yong WOO APMP.M.P-K9 (Absolute pressure up to 110 kpa) 21 May, 2013 In-Mook CHOI*, Sam-Yong WOO (mookin@kriss.re.kr) Contents Backgrounds Schedule & List of Participants Standards of Participants Transfer Standard(TS)

More information

Key comparison automotive gas mixtures Euramet.QM-S4 Final Report

Key comparison automotive gas mixtures Euramet.QM-S4 Final Report Blad 1 van 41 Key comparison automotive gas mixtures Euramet.QM-S4 Final Report Page of 41 VSL Van Swinden Laboratorium B.V., Thijsseweg 11, 69 JA Delft, Nederland INMETRO Instituto Nacional de Metrologia,

More information

LINKING SIM MASS COMPARISONS TO THE KCRV ON 1 kg. Luis O. Becerra CENAM Querétaro, Qro., Mexico,

LINKING SIM MASS COMPARISONS TO THE KCRV ON 1 kg. Luis O. Becerra CENAM Querétaro, Qro., Mexico, LINKING SIM MASS COMPARISONS TO THE KCRV ON 1 kg Luis O. Becerra CENAM Querétaro, Qro., Mexico, lbecerra@cenam.mx Abstract. Within the frame of SIM (Sistema Interamericano de Metrología), inter laboratory

More information

Overview. TC Thermometry Graham Machin. Introduction to TC-T Annual meeting Selected comparisons TC-T training for future thermal metrologists

Overview. TC Thermometry Graham Machin. Introduction to TC-T Annual meeting Selected comparisons TC-T training for future thermal metrologists TC Thermometry Graham Machin Euramet GA 2 June 2015 Overview Introduction to TC-T Annual meeting Selected comparisons TC-T training for future thermal metrologists Workshops COOMET TC-T links EMPIR project

More information

Performance Characteristics of Low-Power Arcjet Thrusters Using Low Toxicity Propellant HAN Decomposed Gas

Performance Characteristics of Low-Power Arcjet Thrusters Using Low Toxicity Propellant HAN Decomposed Gas Performance Characteristics of Low-Power Arcjet Thrusters Using Low Toxicity Propellant HAN Decomposed Gas IEPC-2013-095 Presented at the 33rd International Electric Propulsion Conference, The George Washington

More information

Gas Volumes and the Ideal Gas Law

Gas Volumes and the Ideal Gas Law SECTION 11.3 Gas Volumes and the Ideal Gas Law Section 2 presented laws that describe the relationship between the pressure, temperature, and volume of a gas. The volume of a gas is also related to the

More information

Dear MetNH3 stakeholder,

Dear MetNH3 stakeholder, Dear MetNH3 stakeholder, EMRP JRP MetNH3 Metrology for Ammonia in Ambient Air officially ended on May 31 st 2017. The project partners would like to thank you very much for your interest and your collaboration

More information

Far UV Absorbance Detector

Far UV Absorbance Detector Far UV Absorbance Detector Theory Most organic and inorganic species absorb strongly in the far UV. Notable exceptions are the inert gases, helium and nitrogen which absorb very weakly in this region.

More information

(g) + 3H 2. (g) 2NH 3. (g) (a) Explain what is meant by a dynamic equilibrium. (2)

(g) + 3H 2. (g) 2NH 3. (g) (a) Explain what is meant by a dynamic equilibrium. (2) 1 When nitrogen and hydrogen react to form ammonia, the reaction can reach a dynamic equilibrium. (g) + 3H 2 (g) 2NH 3 (g) (a) Explain what is meant by a dynamic equilibrium. (b) In industry, the reaction

More information

Edited by Naoji Koizumi, Norio Matsumoto and Chjeng-Lun Shieh. GSJ Open-File Report No. 420 GEOLOGICAL SURVEY OF JAPAN

Edited by Naoji Koizumi, Norio Matsumoto and Chjeng-Lun Shieh. GSJ Open-File Report No. 420 GEOLOGICAL SURVEY OF JAPAN Final report of an international cooperative research titled "Hydrological and geochemical research for earthquake prediction in Taiwan (February 2002 - March 2005)" and Proceedings of the third Japan-Taiwan

More information

THE GASEOUS STATE OF MATTER

THE GASEOUS STATE OF MATTER THE GASEOUS STATE OF MATTER The gaseous state of matter is a form of matter in which the particles are in a high state of energy, which causes them to vibrate rapidly, experiencing a strong repulsion among

More information

APMP.T-S6 APMP SUPPLEMENTARY COMPARISON OF INDUSTRIAL PLATINUM RESISTANCE THERMOMETER. Final Report. Prepared by

APMP.T-S6 APMP SUPPLEMENTARY COMPARISON OF INDUSTRIAL PLATINUM RESISTANCE THERMOMETER. Final Report. Prepared by APMP.T-S6 APMP SUPPLEMENTARY COMPARISON OF INDUSTRIAL PLATINUM RESISTANCE THERMOMETER FOR RANGE 50 C TO 400 C Final Report Prepared by Nurulaini Md Ali 1, Hafidzah Othman 1, Mong-Kim Ho 2, Inseok Yang

More information

Croucher Summer Course on Neutron Scattering

Croucher Summer Course on Neutron Scattering Croucher Summer Course on Neutron Scattering August 7-13, 2016 City University of Hong Kong 83 Tat Chee Ave. Kowloon, Hong Kong Sunday August 7: Registration, 14:00 17:00 17:30 Planning meeting with lecturers

More information

Summary of Gas Laws V T. Boyle s Law (T and n constant) Charles Law (p and n constant) Combined Gas Law (n constant) 1 =

Summary of Gas Laws V T. Boyle s Law (T and n constant) Charles Law (p and n constant) Combined Gas Law (n constant) 1 = Summary of Gas Laws Boyle s Law (T and n constant) p 1 V 1 = p 2 V 2 Charles Law (p and n constant) V 1 = T 1 V T 2 2 Combined Gas Law (n constant) pv 1 T 1 1 = pv 2 T 2 2 1 Ideal Gas Equation pv = nrt

More information

TEST-LOCATION SPECIFICATION BY MEANS OF HARDNESS MAPPING ON VICKERS BLOCK SURFACE

TEST-LOCATION SPECIFICATION BY MEANS OF HARDNESS MAPPING ON VICKERS BLOCK SURFACE HARDMEKO 2007 Recent Advancement of Theory and Practice in Hardness Measurement 19-21 November, 2007, Tsukuba, Japan TEST-LOCATION SPECIFICATION BY MEANS OF HARDNESS MAPPING ON VICKERS BLOCK SURFACE Rugkanawan

More information

Working Group 1. Geodetic Reference Frame. Activity Report. for. The UN-GGIM-AP Plenary Meeting

Working Group 1. Geodetic Reference Frame. Activity Report. for. The UN-GGIM-AP Plenary Meeting Regional Committee of United Nations Global Geospatial Information Management for Asia and the Pacific (UN-GGIM-AP) Established by a United Nations Resolution Working Group 1 Geodetic Reference Frame Activity

More information

Coastal Zones & Ocean Science

Coastal Zones & Ocean Science 4 th International Conference on Coastal Zones & Ocean Science Theme: Discovering the Innovative methods for the betterment of Coastal and Ocean science Dates: May 15-16, 2019 Venue: https://coastalzonemanagement.conferenceseries.com/

More information

Part 5- Chemistry Paper 2 Rate and Extent of Chemical Change Combined Science Application

Part 5- Chemistry Paper 2 Rate and Extent of Chemical Change Combined Science Application Part 5- Chemistry Paper 2 Rate and Extent of Chemical Change Combined Science Application How bonding and structure are related to the properties of substances A simple model of the atom, symbols, relative

More information

HOMEWORK 11-1 (pp )

HOMEWORK 11-1 (pp ) CHAPTER 11 HOMEWORK 11-1 (pp. 333 335) VOCABULARY Define. 1. Gay-Lussac s law of combining volumes of gases 2. Avogadro s law Answer each question. 3. Write and explain the equation that expresses the

More information

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS International Gas Union Research Conference 14 THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS Main author Hironori IMANISHI Tokyo Gas Co., Ltd. JAPAN himanishi@tokyo-.co.jp

More information

Magnesium nitride reacts with water to form magnesium hydroxide and ammonia.

Magnesium nitride reacts with water to form magnesium hydroxide and ammonia. Q1. (a) A sample of ethanol vapour, C 2H 5OH (M r = 46.0), was maintained at a pressure of 100 kpa and at a temperature of 366K. (i) State the ideal gas equation. (ii) Use the ideal gas equation to calculate

More information

Final Report on COOMET Key Comparison of Capacitance at 10 pf (COOMET.EM-K4)

Final Report on COOMET Key Comparison of Capacitance at 10 pf (COOMET.EM-K4) State Enterprise All-Ukrainian State Scientific and Production Center of Standardization, Metrology, Certification and Protection of Consumer (SE Ukrmetrteststandard ) Approved by the chairman of TC 1.3

More information

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory Recent Activities on Neutron Standardization at the Electrotechnical Laboratory K. Kudo, N. Takeda, S. Koshikawa and A. Uritani Quantum Radiation Division, National Metrology Institute of Japan (NMIJ)

More information

Human Capacity Building for Natural Resources Development and its Environmental Impacts Tsukuba, Japan, Nov.-Dec., 2007

Human Capacity Building for Natural Resources Development and its Environmental Impacts Tsukuba, Japan, Nov.-Dec., 2007 Human Capacity Building for Natural Resources Development and its Environmental Impacts Tsukuba, Japan, Nov.-Dec., 2007 APEC Industrial, Science and Technical Working Group March 2008 APEC Project No.:

More information

The Uncertainty of Reference Standards

The Uncertainty of Reference Standards 2009 Cerilliant Corporation The Uncertainty of Reference Standards A Guide to Understanding Factors Impacting Uncertainty, Uncertainty Calculations and Vendor Certifications Authors: Ning Chang PhD, Isil

More information

M(N) in compound M(compound). In option A the proportion is 14 = =

M(N) in compound M(compound). In option A the proportion is 14 = = hemistry einemann hemistry 1 5e Unit 1 Practice Exam 1 nswers Section Multiple-choice questions Question 1 Iodine is a covalent molecular substance where all electrons are localised either as a pair of

More information

Elements,Compounds and Mixtures

Elements,Compounds and Mixtures BASIC CONCEPTS: Elements,s and s 1. The smallest fundamental particle of an element that retains the chemical properties of the element is called an atom. 2. A pure substance that cannot be split up into

More information

Measurement & Uncertainty - Basic concept and its application

Measurement & Uncertainty - Basic concept and its application Measurement & Uncertainty - Basic concept and its application Feb. 7. 2012 JongOh CHOI (choijongoh@kriss.re.kr) Knowledge and measurement When you can measure what you are speaking about, and express it

More information

Mass Spectrometry and Chromatography August 24-25, 2018 Singapore

Mass Spectrometry and Chromatography August 24-25, 2018 Singapore conferenceseries.com 7 th Global Congress on Mass Spectrometry and Chromatography August 24-25, 2018 Singapore 100+ 12+ 6+ 50+ 3+ 5+ B2B Participation Interactive Sessions Keynote Lectures Plenary Lectures

More information

Guest Forum. ph Measurement using the Harned Cell. The Screening Committee Lecture for the First Dr. Masao Horiba s Award

Guest Forum. ph Measurement using the Harned Cell. The Screening Committee Lecture for the First Dr. Masao Horiba s Award Guest Forum The Screening Committee Lecture for the First Dr. Masao Horiba s Award ph Measurement using the Harned Cell -ph Values Acceptable for the International Society- Susumu Nakamura National Institute

More information

On the redefinition of the kilogram. Dr Philippe RICHARD

On the redefinition of the kilogram. Dr Philippe RICHARD On the redefinition of the kilogram Dr Philippe RICHARD Agenda 1. Recent history of IPK and new SI 2. The CCM conditions 3. The joint CCM and CCU roadmap 4. The mise en pratique of the definition of the

More information

INTERNATIONAL COMPARISON OF WATER TRIPLE POINT CELLS LEADING TO A MORE PRECISE DEFINITION OF THE KELVIN

INTERNATIONAL COMPARISON OF WATER TRIPLE POINT CELLS LEADING TO A MORE PRECISE DEFINITION OF THE KELVIN INTERNATIONAL COMPARISON OF WATER TRIPLE POINT CELLS LEADING TO A MORE PRECISE DEFINITION OF THE KELVIN Michael Stock and Stéphane Solve Bureau International des Poids et Mesures (BIPM) Pavillon de Breteuil,

More information

Name period AP Unit 8: equilibrium

Name period AP Unit 8: equilibrium Name period AP Unit 8: equilibrium 1. What is equilibrium? Rate of the forward reaction equals the rate of the reverse reaction 2. How can you tell when equilibrium has been reached? The concentrations

More information