The New Quintix. Intuitive application guideance. Maximum accuracy at all time. Easy cleaning. Plug & Work connectivity to printer or computer
|
|
- Ethan Robbins
- 5 years ago
- Views:
Transcription
1 Te New Quintix. Convenient Weiging. Intuitive application guideance Laboratory Balances Maximum accuracy at all time Easy cleaning Plug & Work connectivity to printer or computer AC Adapter Sartorius AC adaptor module wit intercangeable country-specific plug-in AC adaptors Primary V~, 10% +10%, 50 0 Hz, 0. A Secondary 15 V DC, ± 5%, 530 ma (max.) 8 Watt (max.): 0 to +0 C and 15 V DC, ± 5%, 330 ma (max.) 5 Watt (max.): 0 to +50 C Oter data protection class II, in accordance wit EN IEC up to 3000 m above sea level; IP0 as per EN IEC 059 Balance Power supply only via Sartorius AC adaptor module Input voltage V DC Power consumption W (typically) Ambient Conditions Te specifications apply wen te following ambient conditions are in place: Environment for indoor use only Ambient temperature * +10 C to +30 C Operational capacity guaranteed between +5 C and +5 C Storage and sipping 10 C to +0 C Elevation up to 3000 m above sea level Relative umidity** 15% to 80% for temperatures up to 31 C; non-condensing, decreasing linearly to 50% relative umidity at 0 C and 0% at 50 C Safety of electrical equipment Electromagnetic compatibility Defined immunity to interference Interference emission in accordance wit EN /IEC Safety requirements for electrical equipment for mea surement, control, and laboratory use Part 1: General requirements in accordance wit EN 13-1/IEC Electrical equipment for measurement, control, and laboratory use EMC requirements - Part 1: General requirements Suitable for use in industrial areas Class B (suitable for use in residential areas and areas tat are connected to a low voltage network tat also supplies residential buildings). Te device can terefore be used in bot areas. Balances verified for use in legal metrology comply wit te requirements of Council Directive 009/3/EC, EN 5501:199, and OIML R7:00. * For balances verified for use in legal metrology in accordance wit EU requirements, refer to te information on te balance. ** For balances verified for use in legal metrology in accordance wit EU requirements, te legal regulations apply.
2 Tecnical Specifications Standard Equipment Levelling Calibration Selectable weigt units 1 Interface Display Standard built-in applications Special built-in lab applications Languages Protection Password protection Anti-teft lock Underfloor weiging Glass level indicator wit air bubble for centering Internal calibration isocal, External calibration Gram, kilogram, carat, pound, ounce, troy ounce, Hong ong tael, Singapore tael, Taiwan tael, grain, pennyweigts, milligram, parts per pound, Cina tael, mommes, Austrian carat, tola, bat, mesgal and Newton mini USB Automatic recognition of Sartorius printer models YDP30 or YDP0 Direct data transfer to Microsoft Windows programs Programmable interval for data output Data transfer protocols SBI, xbpi, table format, text format Touc screen wit Sartorius grapical user interface optimized for users in parmaceutical laboratories Weiging, Density, Percentage, Ceckweiging, Peak Hold, Counting, Unstable Conditions Mixing, Components, Statistics, Conversion Englis, Frenc, German, Hungarian, Italian, Polis, Portuguese, Russian, Spanis, Turkis, Cinese, Japanese, orean Cemical resistant finis of te ousing In-use cover Dust cover for analytical balances Supervisor lock for protection against unintentional canges ensington lock and lockdown capability for cable or cain Integrated 1 Limited for verified models
3 Analytical Balances Quintix Model 1 Weiging capacity g Readability mg Repeatability (standard deviation) mg Linearity deviation mg Sensitivity drift between +10 C and +30 C ± ppm/ Typical stabilization time s Temperature cange Display result (depending on te set filter level) s Weiging pan size mm d 90 d 90 d 90 Weiging camber eigt mm Net weigt, approx. kg Dimensions, D + W + H mm Inc Models wit a readability of 0.1 mg
4 Precision Balances Quintix Model Weiging capacity g Readability mg Repeatability (standard mg deviation) Linearity deviation mg Sensitivity drift between ± ppm/ C and +30 C Typical stabilization time s Temperature cange Display result (depending on te set filter level) 1 1 s Weiging pan size mm d 10 d 10 d 10 d 10 d 180 d 180 d 180 d 180 Weiging camber eigt mm Net weigt, approx. kg Dimensions, D + W + H mm Inc Models wit a readability of 1 mg
5 Precision Balances Quintix Model Weiging capacity g Readability mg Repeatability (standard mg deviation) Linearity deviation mg Sensitivity drift between ± ppm/ C and +30 C Typical stabilization time s Temperature cange Display result (depending on te set filter level) s Weiging pan size mm d 180 d 180 d 180 d 180 d 180 d 180 d 180 d 180 Weiging camber eigt mm Net weigt, approx. kg Dimensions, D + W + H mm Inc Models wit a readability of 0.01 g, 0.1 g or 1 g
6 Verified Models wit Country-specific Type Approval Certificate Analytical Balances Quintix Model -1x 1 1-1x 1-1x 1 Accuracy class k k k Type SQP-A SQP-A SQP-A Max g Scale interval d mg Verification scale interval e mg Min mg Tare (subtractive) <100 % of te max. weiging capacity Typical stabilization time s Temperature cange Display result (depending on te set filter level) s Weiging pan size mm d 90 d 90 d 90 Weiging camber eigt mm Net weigt, approx. kg Dimensions, D + W + H mm Inc Possible terms for country-specific models: x = CEU: Verified balances wit EC Type Approval Certificate D (for EU except France, Italy, and Switzerland) x = CFR: Verified balances wit EC Type Approval Certificate D for France only x = CIT: Verified balances wit EC Type Approval Certificate D for Italy only x = CCH: Verified balances wit EC Type Approval Certificate D for Switzerland only x = NUS: NTEP Certificate for USA x = CN: CMC Type Approval Certificate for Cina x = 0JP: Balance wit Type Approval Certificate for Japan x = 0BR: Balance wit Type Approval Certificate for Brazil x = 0AR: Balance wit Type Approval Certificate for Argentina x = 0R: Balance wit Type Approval Certificate for Sout orea x = 0RU: Balance wit Type Approval Certificate for Russia x = 0IN: Balance wit Type Approval Certificate for India x = 0CA: Balance wit Type Approval Certificate for Canada All models wit...cn : type SQP
7 Precision Balances Quintix Model 13-1x x x x x x x x 1 Accuracy class Type SQP-B SQP-B SQP-B SQP-B SQP-C SQP-C SQP-C SQP-D Max g Scale interval d mg Verification scale mg interval e Min g Tare (subtractive) < 100 % of te max. weiging capacity Typical stabilization s time Temperature cange Display result s (depending on te set filter level) Weiging pan size mm d 10 d 10 d 10 d 10 d 180 d 180 d 180 d 180 Weiging mm camber eigt Net weigt, approx. kg Dimensions, D + W + H mm Inc Precision Balances Quintix Model 110-1x 1-1x 1-1x 101-1x x x x x 1 Accuracy class Type SQP-D SQP-D SQP-D SQP-E SQP-E SQP-E SQP-E SQP-E Max g Scale interval d mg Verification scale mg interval e Min g Tare (subtractive) < 100 % of te max. weiging capacity Typical stabilization s time Temperature cange Display result s (depending on te set filter level) Weiging pan size mm d 180 d 180 d 180 d 180 d 180 d 180 d 180 d 180 Weiging mm camber eigt Net weigt, approx. kg Dimensions, D + W + H mm Inc
8 Optional Accessories Printers and Communications Premium GLP Laboratory Printer Printer paper for GLP laboratory printer Endless labels for GLP laboratory printer Standard Laboratory Printer Printer paper for standard laboratory printer Data Cable Mini USB USB A Date Cable Mini USB RS3 9-pin General Battery Pack for Standard Lab Balances Draft sield for balances wit a readability of 0.01 g 0.1 g 1 g In-use cover for balances wit a readability of 0.1 mg and 1 mg In-use cover for balances wit a readability of 0.01 g 0.1 g 1 g Dust cover for analytical balances wit draft sield Density Determination Density kit for balances wit a readability of 0.1 mg 1 mg Density kit for balances wit a readability of 0.01 g 0.1 g 1 g YDP30 9Y0385 9Y038 YDP0 9Y0387 YCC0-D09 YCC03-D09 YRB11Z YDS01SQP 90SE01 90SE0 90SE03 YD03 YD0 YDP0, Standard Laboratory Printer
9 Calibration Weigts Calibration for lab balance model ; 313; 13 Proof Line knob weigt 00 g, OIML class E, wit DAkkS certificate Calibration for lab balance model 1 Proof Line knob weigt 100 g, OIML class E, wit DAkkS certificate Calibration for lab balance model Proof Line knob weigt 50 g, OIML class E, wit DAkkS certificate Calibration for lab balance model 13; 513 Proof Line knob weigt 500 g, OIML class E, wit DAkkS certificate Calibration for lab balance model 10; 510 Proof Line knob weigt 5 kg, OIML class E, wit DAkkS certificate Calibration for lab balance model 310; 10 Proof Line knob weigt kg, OIML class F1, wit DAkkS certificate Calibration for lab balance model 110 Proof Line knob weigt 1 kg, OIML class F1, wit DAkkS certificate Calibration for lab balance model 1 Proof Line knob weigt 500 g, OIML class F1, wit DAkkS certificate Calibration for lab balance model 1 Proof Line knob weigt 00 g, OIML class F1, wit DAkkS certificate Calibration for lab balance model 101; 5101; 100; 5100 Proof Line knob weigt 5 kg, OIML class F, wit DAkkS certificate Calibration for lab balance model 101 Proof Line knob weigt kg, OIML class F, wit DAkkS certificate YCW5-AC-0 YCW51-AC-0 YCW5-AC-0 YCW55-AC-0 YCW5-AC-0 YCW3-AC-0 YCW13-AC-0 YCW553-AC-0 YCW53-AC-0 YCW5-AC-0 YCW-AC-0 Calibration weigts
10 Tecnical Drawings Models wit a readability of 0.1 mg, in mm Models wit a readability of 1 mg, in mm
11 Models wit a readability of > 10 mg, in mm
The New Quintix. Convenient Weighing. Benefits. Technical Specifications
The New Quintix. Convenient Weighing. Benefits Intuitive application guideance Maximum accuracy at all time Easy cleaning Plug & Work connectivity to printer or computer Technical Specifications AC Adapter
More informationThe New Semi-Micro Balances Quintix
The New Semi-Micro Balances Quintix Benefits Top Performance Intuitive Operation Easy-to-Clean Design Ergonomic Draft Shield Space-saving Footprint Product Information The new Sartorius semi-micro balances
More informationThe New Secura. No Risk!
The New Secura. Safe & Secure Weighing. No Risk! Laboratory Balances Blocked data transfer to printer or computer if... the balance is not leveled correctly the SQmin value is not observed the balance
More informationThe New Secura. No Risk!
The New Secura Easy, Reliable Weighing in Regulated Areas. No Risk! Laboratory Balances Blocked data transfer to printer or computer if... the balance is not leveled correctly the SQmin value is not observed
More informationThe New Practum. Unmatched reliability with the world-class weighing instrument
The New Practum Start Weighing Right. Unmatched reliability with the world-class weighing instrument Laboratory Balances Made in Germany Overload protection for years of reliability Supervisor Lock Fast
More informationThe New Practum. Start Weighing Right. Benefits. Technical Specifications
The New Practum. Start Weighing Right. Benefits Unmatched reliability with the world-class weighing instrument Made in Germany Overload protection for years of reliability Supervisor Lock Fast and easy
More informationPractum. Benefits. Product Information. Technical Specifications
Practum Benefits Unmatched reliability with the world-class weighing instrument Overload protection for years of reliability Supervisor Lock Fast and easy data transfer Product Information Get best value
More informationThe New Entris. Monolithic weigh cell for long-term high accuracy. Built-in applications and function keys for convenient operation
The New Entris. Just Weighing. Monolithic weigh cell for long-term high accuracy Laboratory Balances Built-in applications and function keys for convenient operation Backlit, high-contrast display for
More informationThe New Entris. Monolithic weigh cell for long-term high accuracy. Built-in applications and function keys for convenient operation
The New Entris. Just Weighing. Monolithic weigh cell for long-term high accuracy Laboratory Balances Built-in applications and function keys for convenient operation Backlit, high-contrast display for
More information610,- KERN ADB. Analytical balances. Quick-Finder Analytical balances. Large glass draught shield with 3 sliding doors
Quick-Finder Readout [d] mg Weighing [Max] g Price excl. of VAT Page 0,01 101 ABT 100-5NM 1980,- 39 1 0,01 0,1 42 120 ABT 120-5DNM 2120,- 39 1 0,01 0,1 82 220 ALJ 200-5DA 1750,- 37 1 0,01 0,1 82 220 ABT
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing
More informationGet the reliability and quality of a Sartorius balance, but only pay for the features you really need.
Entris Benefits Monolithic weigh cell for long-term high accuracy Built-in applications and function keys for convenient operation Backlit, high-contrast display for user-friendly guidance Product Information
More informationPascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure
DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and
More informationProduct Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541
Product Data Sound Intensity Calibrator Type 3541 USES: Sound intensity and particle velocity calibrations Sound pressure calibration Measurement of pressure-residual intensity index FEATURES: Intensity
More informationAutomatic titrators, TitroMatic
112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator
More informationINTERNATIONAL OIML R 61-2 RECOMMENDATION
INTERNATIONAL OIML R 61-2 RECOMMENDATION Edition 2004 (E) Automatic gravimetric filling instruments Part 2: Test report format Doseuses pondérales à fonctionnement automatique Partie 2: Format du rapport
More informationCALYS 80P. Field pressure calibrator with high accuracy 0.01%
Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationProduct Data. Brüel & Kjær B. Sound Power Source Type Introduction
Product Data Sound Power Source Type 425 USES: Determination of sound power output of equipment by the Substitution Method Determination, by the Juxtaposition Method, of sound power output of equipment
More informationCTC 155 / 350 / 660 Dry-block calibrator
CTC 155 / 350 / 660 Dry-block calibrator Wide temperature range: CTC-155: -25 to 155 C CTC-350: 28 to 350 C CTC-660: 28 to 660 C Fast calibration External reference sensor External sensor control Easy
More informationRoHS. Versatile. X g. X 2 e
s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k
More informationSemi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities
Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities instruments 5 YEARS G U A R A N T E E Quality at a reasonable price The optimum combination
More informationAnalogue Meters CQ2x07 series
Analogue Meters CQ2x07 series Analogue Power Meters Active, reactive, apparent power meters and Power factor meters with exchangeable scales EQ0207/2207/0107/2107 & YQ0207/2207/0107/2107 o Measurement
More informationDM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability
DM70 Hand-held Dewpoint Meter Truly Fast Response - Superior Long-term Stability DM70 - When Dry Air Is Important The Vaisala DM70 Hand-held Dewpoint Meter offers stable and fast measurement for industrial
More informationCompact Titration. Compact Titrator G20. One Click Titration Simple & Dependable
Compact Titration Compact Titrator G20 One Click Titration Simple & Dependable Simplicity The Intelligent Helper for Simple Titrations One Click Titration Intuitive method adaptation Accurate results simply
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationInfrared Hand-Held Thermometers
Infrared Hand-Held Thermometers measuring monitoring analysing Model: TIR-H... Measuring range from -2 to 5 C to -32 to 9 C Measuring accuracy: ±1% to ± 2% of measured value Option: analogue output, RS
More information473-SHX Dew Point Mirror
Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More informationSVH with HYDROVAR (HVL range)
SVH with HYDROVAR (HVL range) SVH-HVL Rev. B Ed.9/1 (EN) SVH SERIES (e-sv WITH HYDROVAR) Background and context For all pumping needs in commercial or residential building and in industry applications,
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationOIML R 51-2 RECOMMENDATION. Edition 2006 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Automatic catchweighing instruments
INTERNATIONAL RECOMMENDATION OIML R 51-2 Edition 2006 (E) Automatic catchweighing instruments Part 2: Test report format Instruments de pesage trieurs-étiqueteurs à fonctionnement automatique Partie 2:
More informationOIML R 50-3 RECOMMENDATION. Edition 2014 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION
INTERNATIONAL RECOMMENDATION OIML R 50-3 Edition 2014 (E) Continuous totalizing automatic weighing instruments (belt weighers). Part 3: Test report format Instruments de pesage totalisateurs continus à
More informationThe Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:
The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering
More information1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter
1/5 Specification Hidex 300 SL-SLL 100-240V AC and 24 V DC. Features Model (425-020) Super Low Level (SLL) Automatic TDCR Liquid Scintillation Counter with Guard Detector and Low Level PMTs General Description
More informationType UB1 Load Cell. Option Stainless steel cable gland
Type UB1 Load Cell IP68 APPROVED Product Description Type UB1 is a stainless steel universal load cell which allows for tension and compression loading. Its complete hermetic sealing makes it suitable
More information5730A High Performance Multifunction Calibrator. Extended specifications
730A High Performance Multifunction Calibrator Extended specifications General Specifications Warm-Up Time... Twice the time since last warmed up, to a maximum of 30 minutes. System Installation... Rack
More informationph/redox Measurement CPM 280
Technical Information TI 346C/07/en/07.03 51511752 ph/redox Measurement CPM 280 Battery-driven pocket meter for ph and redox measurement Application CPM 280 is a compact pocket meter for measuring ph value
More informationAir velocity & IAQ measuring instruments
Data sheet dp Air velocity & IAQ measuring instruments - air velocity & IAQ measuring instrument - dp air velocity & IAQ measuring instrument incl. differential pressure C CO Intuitive: clearly structured
More informationCALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%
ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationEVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser
EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser The latest innovation in total Suspended Particulate Matter (SPM) measurement The Measure of Technology Made in Germany TÜV CERTIFIED
More information473 Dew Point Hygrometer
gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationROTANTA 460/460 R Benchtop, Underbench and Floorstanding Centrifuges classic/cooled
Benchtop, Underbench and Floorstanding Centrifuges classic/cooled PERFORMANCE Efficient, results-oriented working processes are top priority in both research and routine laboratories. Advanced laboratory
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More information2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22
.1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk
More informationembiscan Barecode configurator embisphere Tél: +33(0)
embiscan Barecode configurator embisphere 85 rue du Molinel 59700 MARCQ-EN-BAROEUL - FRANCE www.embisphere.com Tél: +33(0) 3 20 28 86 00 REVISION HISTORY Rev Date Author Description 1.0 21/05/2015 Tristan
More informationPHOS 15 LED PROJECTOR
PHOS 15 LED PROJECTOR SPECIFICATIONS Item:.. PHOS 15 Body:.... Aluminium Available Colours:... White / Black / Silver Weight:.... 1.9 kg On / Off Switch:..... Not Available Environmental Conditions:.....
More informationCompact Titration Compact Titrator G20. One Click Titration Simple & Dependable
Compact Titration Compact Titrator G20 One Click Titration Simple & Dependable Simplicity The Intelligent Helper for Simple Titrations One Click Titration Intuitive method adaptation Accurate results simply
More informationSolenoid valves Type EVUL
Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More informationKERN ADB. Analytical balances. Quick-Finder Analytical balances. see page 35. Large glass draught shield with 3 sliding doors
Quick-Finder Readout Weihin rane Pae 0,01 101 ABT 100-5NM 39 1 0,01 0,1 42 120 ABT 120-5DNM 39 1 0,01 0,1 82 220 ALJ 200-5DA 37 1 0,01 0,1 82 220 ABT 220-5DNM 39 1 0,1 82 ABS 80-4N 38 1 0,1 82 ABJ 80-4NM
More informationWT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430
WT L- Laser Photoelectric proximity switches, background suppression -- DC 00...00 mm Photoelectric proximity switches Dimensional drawing.. Laser LED, red light Adjustable background suppression 0 0.
More informationMoisture Analyzers.
Moisture Analyzers MS-70/MX-50 MF-50/ML-50 http://www.aandd.jp Select the best for your applic A&D's Moisture Analyzers MS-70/MX-5 MS-70/MX-5 Fast and uniform heating with halogen lamp and innovative SRA
More informationZ7A. Load cells. Special features. Data sheet. Wiring code
Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More information1. (a) 3. (a) 4 3 (b) (a) t = 5: 9. (a) = 11. (a) The equation of the line through P = (2, 3) and Q = (8, 11) is y 3 = 8 6
A Answers Important Note about Precision of Answers: In many of te problems in tis book you are required to read information from a grap and to calculate wit tat information. You sould take reasonable
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationINFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication
Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs
More informationOIML R RECOMMENDATION. Edition 2006 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Instruments for measuring the areas of leathers
INTERNATIONAL RECOMMENDATION OIML R 136-2 Edition 2006 (E) Instruments for measuring the areas of leathers Part 2: Test Report Format Instruments pour la mesure de la surface des cuirs Partie 2 : Format
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationInfrared Hand-Held Thermometers
Infrared Hand-Held Thermometers measuring monitoring analysing Model: TIR-H... Measuring range from -2... 5 C to -32... 9 C Measuring accuracy: ±1% to ± 2% of measured value Option: analogue output, RS
More informationAir velocity & IAQ measuring instruments
Data sheet dp Air velocity & IAQ measuring instruments - air velocity & IAQ measuring instrument - dp air velocity & IAQ measuring instrument incl. differential pressure C CO Intuitive: clearly structured
More informationOIML R 76-2 RECOMMENDATION. Edition 2007 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Non-automatic weighing instruments
INTERNATIONAL RECOMMENDATION OIML R 76-2 Edition 2007 (E) Non-automatic weighing instruments Part 2: Test report format Instruments de pesage à fonctionnement non automatique Partie 2: Format du rapport
More informationMulti-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits
200 > Measurement and instrumentation Programmable digital transducers TRIAD 2 range Programmable digital transducers with to 4 analogue outputs Programmable accuracy class PRODUCT ADVANTAGES Up to 4 PROGRAMMABLE
More informationKeysight Technologies Measurement Uncertainty of VNA Based TDR/TDT Measurement. Application Note
Keysight Technologies Measurement Uncertainty of VNA Based TDR/TDT Measurement Application Note Table of Contents Introduction... 3 S-parameter measurement uncertainty of VNA... 4 Simplification of systematic
More informationKjeltec 2300 Analyzer Unit
Kjeltec 2300 Analyzer Unit Automatic distillation and approved colorimetric titration for analysis of Kjeldahl nitrogen/protein, ammonium- nitrogen, TKN, Direct distillation (DD), volatile acids/ bases
More information65 0.26 Pascal-STV/ZB DIFFERENTIAL PRESSURE MEASUREMENT INSTRUMENT WITH ANALOG OUTPUT & DISPLAY 60 0.24 - CLEAN ROOMS - FILTER SYSTEMS - LAMINAR FLOWBOXES - AIR LOCKS 55 0.22 - FUME HOODS - ISOLATORS General
More informationJAPAN QUALITY. Automated Clinical Analyzer
JAPAN QUALITY Automated Clinical Analyzer Higher test performance and operability with new functions The clinical analyzer in the next stage 1 The best to the requirements for functionality and usability
More informationDRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach
NEW DRS : Incremental encoders, number of lines and zero pulse width freely programmable DRS : s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationBOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION
BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER Technical Description Version 2 BGRIMM AUTOMATION, South 4th Ring Road West, Beijing, China TEL: +86(10)59069762 Fax: +86(10)68360101 Contents BGRIMM AUTOMATION
More informationAnalog - Digital multimeters
CAT-IV -3, MI, Satpur, Nashik-4 7,India. Tel.: +9 53 6, ax : +9 53 3564 Page of / 5 / I I / 7 / B Automatic Terminal Blocking System (ABS) The automatic Terminal blocking system prevents incorrect connection
More information792A AC/DC Transfer Standard
92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1
More informationHD32.2 WBGT Index HD32.3 WBGT-PMV. [ GB ] - WBGT index. - PMV index and PPD
HD32.2 WBGT Index HD32.3 WBGT-PMV [ GB ] - WBGT index. - PMV index and PPD [ GB ] [ GB ] Description HD32.2 WBGT Index is an instrument made by Delta Ohm srl for the analysis of WBGT index (Wet Bulb Glob
More information+ + ( indicator ) + (display, printer, memory)
CERTIFICATION OF STRAIN GAUGE LOAD CELL FAMILIES B. Meissner Physikalisch-Technische Bundesanstalt Weighing Instruments Laboratory 38116 Braunschweig, Germany Abstract: Testing and certification of load
More informationPYCKO SCIENTIFIC LIMITED
PYCKO SCIENTIFIC LIMITED 31 London Road, Grantham, NG31 6EX Telephone 01476 401992 bill@pycko.co.uk www.pycko.co.uk Your Alternative To The Obvious RayMon10 TM Detect, measure, identify and analyse radionuclides
More informationBright Advance Corporation
USER INSTRUCTIONS TABLE OF CONTENTS INSTRUCTIONS FOR USE2 PREPARING TO USE THE SCALE2 DISPLAYS3 KEYBOARD FUNCTION4 OPERATION7 COUNTING14 DIFFERENT KEYBOARD TYPES21 INTERFACE31 POWER SOURCES40 1 INSTRUCTIONS
More informationGW Professional Weighing Scale. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW
GW Professional Weighing Scale User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW 20100415 Table of Contents Table of Contents...1 Specifications... 2 Basic specification... 2 Series specification(ec TYPE/OIML
More informationTHM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist
THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,
More information4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)
.2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof
More informationSINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol
SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.
More informationMobile coulometer for water determination anywhere you want
899 Coulometer Mobile coulometer for water determination anywhere you want Extremely small & compact Maximum flexibility due to independent power supply Automatic start of titration 899 Coulometer the
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationHD32.2 WBGT Index HD 32.2 INSTRUMENT FOR THE ANALYSIS OF THE WBGT INDEX
HD32.2 WBGT Index HD32.2 instrument can detect simultaneously the following quantities Globe thermometer temperature Tg. Wet bulb temperature with natural ventilation Tn. Environment temperature T. Starting
More information2100TR Liquid Scintillation Counter
2100TR Liquid Scintillation Counter Description The Tri-Carb 2100TR liquid scintillation counter is computer-controlled, bench top liquid scintillation analyzer for detecting small amounts of alpha, beta
More information7.5A LOW DROP POSITIVE VOLTAGE REGULATOR ADJUSTABLE AND FIXED. October 2002
THREE TERMINAL ADJUSTABLE OR FIXED OUTPUT VOLTAGE 1.5V,1.8V, 2.5V, 3.0, 3.3V OUTPUT CURRENT UP TO 7.5A 1.4V MAX DROPOUT VOLTAGE AT FULL LOAD LINE REGULATION: MAX 0.2% OVER FULL TEMPERATURE RANGE LOAD REGULATION:
More informationISEmax CAS40D. Technical Information
Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor
More informationW 9 L: Laser photoelectric switches: small, light and reliable
W 9 Laser photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 9 L: Laser photoelectric switches: small, light and reliable The
More informationAccuracy Calibration Certificate
gl06-0-067-acc Mettler Toledo Service Business Unit Industrial 900 Polaris Parkway Columbus, OH 0-800-- Services Provided By: Customer Accuracy Calibration Certificate Company: Sample Company Test Address:
More informationTwo year warranty. Two year warranty
WEIGH TO GO FISHERBRAND offers quality, reliability and value. The comprehensive range of laboratory balances are ideally suited to meet a wide range of routine weighing applications. The balances will
More information2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)
.1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines
More informationOne-hand ph/temperature measuring instrument
One-hand ph/temperature measuring instrument testo 205 ph tip embedded in breakage-proof plastic ph Combined penetration tip with temperature probe Maintenance-free gel electrolyte C Measurement tip exchangeable
More information