1 QT 2X26 42/ S QUICKTRONIC MULTIWATT ECG for CFL QT 2X26 42/ S Page 1 of 16
2 Technical data Electrical data Line current Nominal voltage Mains frequency DC voltage 0.39 A V Hz V Operating frequency 45 khz 1) Max. no. of ECGs on circuit breaker 10 A 17 Max. no. of ECGs on circuit breaker 16 A 28 1) Approximately Dimensions & weight Length Width Height Mounting hole spacing, length Product weight mm 79.0 mm 33.0 mm mm g QT 2X26 42/ S Page 2 of 16
3 Product line drawing with letters Temperatures C Capabilities Suitable for fixtures with prot. class I / II End of Life safety shutdown EOL T.2 Certificates & standards Approval marks approval EEI Energy Label Standards E1 approval / VDE / VDE-EMC A2 acc. to EN / acc. to EN / acc. to EN 55015: A1:2007 / acc. to EN / acc. to EN QT 2X26 42/ S Page 3 of 16
4 Lamp-ECG combination (System) DULUX D/E 26 W + Power loss 0.23 (A) 1800 (lm) DULUX D/E 26W/827 G24Q-3 DULUX D/E 26W/830 G24Q-3 DULUX D/E 26W/835 G24Q-3 DULUX D/E 26W/840 G24Q-3 DULUX D/E 26W/865 G24Q-3 DULUX F 24 W + Power loss 0.23 (A) 1700 (lm) DULUX F 24W/827 2G10 DULUX F 24W/830 2G10 DULUX F 24W/840 2G10 QT 2X26 42/ S Page 4 of 16
5 DULUX F 36 W + Power loss 0.30 (A) 64 (W) 6.00 (W) 2700 (lm) DULUX F 36W/827 2G10 DULUX F 36W/830 2G10 DULUX F 36W/840 2G10 DULUX L 24 W XT + Power loss 0.23 (A) 1750 (lm) DULUX L 24 W/830 XT DULUX L 24 W/840 XT DULUX L 24 W + Power loss 0.23 (A) 1750 (lm) QT 2X26 42/ S Page 5 of 16
6 DULUX L 24W/67 blue 2G11 DULUX L 24W/827 2G11 DULUX L 24W/830 2G11 DULUX L 24W/830 SP 2G11 DULUX L 24W/835 2G11 DULUX L 24W/840 2G11 DULUX L 24W/865 SP 2G11 DULUX L 24W/930 2G11 DULUX L 24W/940 2G11 DULUX L 24W/954 2G11 DULUX L 36 W XT + Power loss 0.30 (A) 64 (W) 6.00 (W) 2800 (lm) DULUX L 36 W/830 XT DULUX L 36 W/840 XT DULUX L 36 W + Power loss 0.30 (A) 64 (W) 6.00 (W) 2800 (lm) QT 2X26 42/ S Page 6 of 16
7 DULUX L 36W/827 2G11 DULUX L 36W/830 2G11 DULUX L 36W/835 2G11 DULUX L 36W/840 2G11 DULUX L 36W/860 2G11 (OAPAC) DULUX L 36W/865 2G11 DULUX L 36W/930 2G11 DULUX L 36W/940 2G11 DULUX L 36W/954 2G11 DULUX T/E 26 W CONSTANT + Power loss 0.23 (A) 1800 (lm) DULUX T/E 26W/830 CONSTANT GX24Q DULUX T/E 26W/840 CONSTANT GX24Q DULUX T/E 26 W + Power loss 0.23 (A) 1800 (lm) QT 2X26 42/ S Page 7 of 16
8 DULUX T/E 26W/827 PLUS GX24Q DULUX T/E 26W/830 CONSTANT GX24Q DULUX T/E 26W/830 PLUS GX24Q DULUX T/E 26W/840 CONSTANT GX24Q DULUX T/E 26W/840 PLUS GX24Q DULUX T/E 32 W CONSTANT + Power loss 0.30 (A) 64 (W) 6.00 (W) 2400 (lm) DULUX T/E 32W/827 CONSTANT GX24Q DULUX T/E 32W/830 CONSTANT GX24Q DULUX T/E 32W/840 CONSTANT GX24Q DULUX T/E 32 W + Power loss 0.30 (A) 64 (W) 6.00 (W) 2400 (lm) DULUX T/E 32W/827 CONSTANT GX24Q DULUX T/E 32W/827 PLUS GX24Q DULUX T/E 32W/830 CONSTANT GX24Q DULUX T/E 32W/830 PLUS GX24Q DULUX T/E 32W/840 CONSTANT GX24Q DULUX T/E 32W/840 PLUS GX24Q DULUX T/E 42W/827 GX24Q (OAPAC, other region) QT 2X26 42/ S Page 8 of 16
9 DULUx T/E 42 W CONSTANT + Power loss 0.39 (A) 87 (W) 3200 (lm) DULUX T/E 42W/827 CONSTANT GX24Q DULUX T/E 42W/830 CONSTANT GX24Q DULUX T/E 42W/840 CONSTANT GX24Q DULUX T/E 42 W + Power loss 0.39 (A) 87 (W) 3200 (lm) DULUX T/E 42W/827 CONSTANT GX24Q DULUX T/E 42W/827 PLUS GX24Q DULUX T/E 42W/830 CONSTANT GX24Q DULUX T/E 42W/830 PLUS GX24Q DULUX T/E 42W/840 CONSTANT GX24Q QT 2X26 42/ S Page 9 of 16
10 FC W + Power loss 0.36 (A) 64 (W) 6.00 (W) 5000 (lm) FC 22W/827 2GX13 FC 22W/830 2GX13 FC 22W/840 2GX13 FC 22W/865 2GX13 FC 40W/827 2GX13 FC 40W/830 2GX13 FC 40W/840 2GX13 FC 40W/865 2GX13 FC 22 W + Power loss 0.36 (A) 1800 (lm) FC 22W/827 2GX13 FC 22W/830 2GX13 FC 22W/840 2GX13 FC 22W/865 2GX13 QT 2X26 42/ S Page 10 of 16
11 FC 40 W + Power loss 0.36 (A) 80 (W) 8.00 (W) 3200 (lm) FC 40W/827 2GX13 FC 40W/830 2GX13 FC 40W/840 2GX13 FC 40W/865 2GX13 HO 24 W CONSTANT + Power loss 0.23 (A) 1900 (lm) HO 24 W/830 CONSTANT HO 24 W/840 CONSTANT HO 24 W/865 CONSTANT HO 24 W + Power loss 0.23 (A) 3500 (lm) QT 2X26 42/ S Page 11 of 16
12 HO 24 W/60 HO 24 W/66 HO 24 W/67 HO 24 W/827 HO 24 W/830 HO 24 W/830 CONSTANT HO 24 W/835 HO 24 W/840 HO 24 W/840 CONSTANT HO 24 W/865 HO 24 W/865 CONSTANT HO 24 W/880 HO 24 W/940 HO 24 W/965 L 36 W + Power loss 0.30 (A) 64 (W) 6.00 (W) 3200 (lm) QT 2X26 42/ S Page 12 of 16
13 L 36W/530 L 36W/535 L 36W/60 L 36W/62 L 36W/640 L 36W/66 L 36W/67 L 36W/73 L 36W/730 SMARTLUX L 36W/740 SMARTLUX L 36W/76 L 36W/76 SPS L 36W/765 L 36W/765 SMARTLUX L 36W/77 L 36W/780 L 36W/827 L 36W/830 L 36W/835 L 36W/840 L 36W/840 SPS L 36W/850 L 36W/860 L 36W/865 L 36W/880 SKYWHITE L 36W/930 L 36W/940 L 36W/940 UVS L 36W/950 COLOR PROOF L 36W/954 L 36W/954 UVS L 36W/965 L 36W/965 BIOLUX QT 2X26 42/ S Page 13 of 16
14 Wiring diagram Wiring diagram QT 2X26 42/ S Page 14 of 16
15 Logistical Data Product code Packaging unit (Pieces/Unit) Dimensions (height x width x length) Gross weight Volume Unpacked Shipping carton box mm x 75 mm x 124 mm 260 mm x 101 mm x 412 mm g 0.31 dm³ g dm³ QT 2X26 42/ S Page 15 of 16
16 Disclaimer Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release. QT 2X26 42/ S Page 16 of 16
QTi DALI-T/E 2X18 42/ DIM
QTi DALI-T/E 2X18 42/220 240 DIM QUICKTRONIC INTELLIGENT DALI DIM CFL ECG dimmable DALI for CFL Suitable for emergency light installations Product benefits Easy change of defect ECG thanks to available
More informationA NEW GENERATION OF ECGs QUICKTRONIC MULTIWATT ONE FOR MANY THERE IS LIGHT. AND THERE IS OSRAM.
A NEW GENERATION OF QUICKTRONIC ONE FOR MANY THERE IS LIGHT. AND THERE IS OSRAM. ONE FOR MANY: THE NEW GENERATION OF VERSATILE. TOO MANY SPECIALISTS Without putting too fine a point on it, traditional
More informationPRODUCT FAMILY DATASHEET LEDVANCE FLOODLIGHT LED
LEDVANCE FLOODLIGHT LED LED floodlight luminaires AREAS OF APPLICATION Replacement for floodlights with halogen lamps Car parks and underpasses Garages Public areas Building facades Construction areas
More informationPrevaLED COIN 50 COB G1
PrevaLED COIN 50 COB G1 LED modules with integrated optics and heat sink Areas of application _ Retail outlets _ Shop lighting _ Restaurants _ Hospitality _ Museums, galleries Product benefits _ Compact
More informationPrevaLED COIN 50 DC COB G1
PrevaLED COIN 50 DC COB G1 LED modules with integrated optics and heat sink Areas of application _ Retail outlets _ Shop lighting _ Restaurants _ Hospitality _ Museums, galleries Product benefits _ Compact
More informationPRODUCT FAMILY DATASHEET TRACKLIGHT SPOT D75 25W
TRACKLIGHT SPOT D75 25W 3-phase tracklight spot with integrated control gear, low wattage AREAS OF APPLICATION Direct replacement for luminaires using HID lamps Accent lighting Fashion shops, accessories
More informationPRODUCT FAMILY DATASHEET LEDVANCE FLOODLIGHT LED STD
PRODUCT FAMLY DATASHEET LEDVANCE FLOODLGHT LED STD LED floodlights AREAS OF APPLCATON Architectural lighting Landscape lighting ndustrial and commercial halls Billboard lighting Security lighting Car parks
More informationFL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact
FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per
More information595,7 ± 1,2. [in mm] 25,0 ± 1,5
T8 XT 18W LUMILUX 595,7 ± 1,2 589,8 604,0 Lamp wattage (W) : 18 Nominal current (CCG-operation) uncompensated (A) : 0,37 Lamp arc voltage UL after switch-on (± 10%) (V) : 57 Resistance / Impedance Z (for
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationQT-Brightek High Power Series. 0.5W High Power 2835 LED
QT-Brightek High Power Series 0.5W High Power 2835 LED Part No.: QBHP686-IWH-XX XX = WW/NW/CW Product: QBHP686-IWH-XX Date: August 04, 2017 Page 1 of 11 Table of Contents: Introduction... 3 Electrical
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationQT-Brightek High Power Series. 0.5W High Power 2835 LED
QT-Brightek High Power Series 0.5W High Power 2835 LED Part No.: QBHP686-XXH Series XX = Color Code H = 150mA Product: QBHP686-XXH Series Date: June 20, 2017 Page 1 of 12 Tablet of Contents: Introduction...
More information2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22
.1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk
More informationPHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact
EL Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A BAT Noise-free precise control via DSI signal, switchdim or corridorfunction Nominal life
More informationCLUSTERLITE CONTENTS MEGAMAN
CONTENTS Specifications for... 2.1 Maximum Temperature Declaration... 2.3 Lumen Maintenance Curve... 2.4 Vs. Temperature... 2.6 Run-up Time... 2.8 Specifications for Power Supply... 2.1 Line Drawings for
More informationINFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication
Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs
More informationFL ballasts Electronic dimming. PCA TC ECO Y II, W ECO compact
FL ballasts EL TC-F TC-SEL TC-L HE TC-DD Tc PCA TC ECO Y II, 7 W ECO compact Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A BAT Noise-free
More informationfür for T5-Lampen fluorescent in Multi-Lamp-Technologie
Dimmbare Dimmable electronic elektronische control Vorschaltgeräte gear für for T-ampen fluorescent in Multi-amp-Technologie lamps in technology M-tec Performance characteristics Dimmable ECG in Multi-amp
More informationLEDlight 20 W Universal dimmable series
LEDlight 20 W Universal dimmable series L05011i2 / L05011i3 / L05011i4 Lumotech technology Lumotech LED drivers are designed to efficiently power and control LED solutions for general lighting applications.
More informationLEDlight 30 W Universal dimmable series
LEDlight 30 W Universal dimmable series L05031 Lumotech technology Lumotech LED drivers are designed to efficiently power and control LED solutions for general lighting applications. System reliability
More informationEmergency lighting units EM Inverter
T T TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM G, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps ow-profile casing
More informationPowerful, ultra-slim circular lamps
Powerful, ultra-slim circular lamps T5 Circular Philips T5 Circular lamps are ultra-slim with improved color rendering, higher efficacy, and longer life.t5 HO circular lamps offer extraordinary light output.
More informationEMI Suppression PCRC 420 film capacitors (RC unit)
MKP RADIAL POTTED CAPACITORS Pitch 15.0/17.5 mm P = 15.0 / 17.5mm QUICK REFERENCE DATA Capacitance value Capacitance tolerance Resistance value Resistance tolerance Rated (AC) voltage 50 to 60 Hz Climatic
More informationBETA Protecting Miniature Circuit Breakers
Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationLED Entryway Light RoHS
72508 LED Entryway Light RoHS QPL ID # PSMN8JUU Model: 72508 Input Voltage 120-277 VAC 60HZ Input Current 0.5A Max @120V Input Power 25W Power Factor PF 0.95 OVERALL LAMP PARAMETERS Luminance 3,121 LM
More informationSHP-T Basic Plus. Sa Shp-T 150w Basic Plus E40 PRODUCT OVERVIEW DATA TABLE. Optical data. Range Features. Colour temperature (K) 2000 CRI (Ra) 20
Range Features PRODUCT OVERVIEW Lamp finish clear Lamp shape High Pressure Sodium Colour temperature (K) 2000 CRI (Ra) 20 Dimmable Yes EAN code 5410288208473 Energy class A+ Cap/Base E40 Type SHP-T Watt
More informationExplosion-protected recessed ceiling LED-light and fluorescent light fittings
.7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX
More informationTechnical Application Guide for Phaeton LED Floodlight
PHAETON LED Technical Application Guide for Phaeton LED Floodlight PH15FL8 All can be equipped with sensor. Introduction PHAETON 15W LED floodlight integrates bridgelux 45mil chip and a compact high efficient
More informationRevision checklist SP10. SP10 Electricity and Circuits. SP10a Electric circuits. SP10b Current and potential difference
Electricity and Circuits a Electric circuits Describe the basic structure of an atom (positions, relative masses and relative charges of protons, neutrons and electrons). Recognise the circuit symbols
More informationEx-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)
Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including
More informationISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER
ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection
More informationQT-Brightek PLCC4 Series PLCC4 RGB LED
QT-Brightek PLCC4 Series PLCC4 RGB LED Part No.: QBLP677-RGB2 (High Bright) Product: QBLP677-RGB2 (High Bright) Date: June 28, 2016 Page 1 of 10 Table of Contents: Introduction... 3 Electrical / Optical
More information2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)
.1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines
More informationRoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.
Cat# 71893 380W LED FlatPanel Slipfitter Mount OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output
More informationE C K T H C K B
Ceramic Capacitors (Safety Regulations) For Surface Mounting s HC (Sub-Class Y1) FC (Sub-Class Y2) C (Sub-ClassY2 ) Features Resin molded SMD type for flow/reflow soldering (HC) and reflow soldering (FC,C)
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More informationPHYSICS 171 UNIVERSITY PHYSICS LAB II. Experiment 6. Transient Response of An RC Circuit
PHYSICS 171 UNIVERSITY PHYSICS LAB II Experiment 6 Transient Response of An RC Circuit Equipment: Supplies: Function Generator, Dual Trace Oscilloscope.002 Microfarad, 0.1 Microfarad capacitors; 1 Kilohm,
More informationZinc Oxide Varistors. VE/VF Types for Heavy Duty Applications ( P Series ) FEATURES PARTICULAR CHARACTERISTICS 18 TPC
VE/VF Types for Heavy Duty Applications ( P Series ) FEATURES P Series are especially dedicated to heavy duty applications encountered in the AC power network. Higher surge current and energy ratings provide
More informationEnergy labelling for refrigerating appliances for household use
Ref: 5005374-2568-0001/151298 page 1/14 VDE Prüf- und Zertifizierungsinstitut VDE Testing and Certification Institute TEST REPORT EN 153:2006 EN ISO 15502:2005 Energy labelling for refrigerating appliances
More informationQT-Brightek PLCC Series
QT-Brightek PLCC Series PLCC4 RGB LED Part No.: QBLP677-RGB (High Bright) Product: QBLP677-RGB (High Bright) Date: August 29, 2016 Page 1 of 10 Table of Contents: Introduction... 3 Electrical / Optical
More informationLab 8 Simple Electric Circuits
Lab 8 Simple Electric Circuits INTRODUCTION When we talk about the current in a river, we are referring to the flow of water. Similarly, when we refer to the electric current in a circuit, we are talking
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More informationCat# LED Linear High Bay 100W
Cat# 71724 LED Linear High Bay 100W QPL ID # PRNKSMPK OVERALL LAMP PARAMETERS LED DRIVER LIFESPAN & ENVIRONMENT OTHERS Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency
More informationAC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC
AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC FEATURES Complying with IEC 60384-14 4 th edition Can pass 10 kv pulses (10 per polarity) Withstands 85 / 85 / 1000 h test Reduced
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More informationInterference Suppression PCX2 335 film capacitors
MKP RADIAL POTTED CAPACITORS Pitch 15.0/22.5/27.5mm QUICK REFERENCE DATA Capacitance range (E6 series) * 0.01to 1.0 Capacitance tolerance 10 %, 20 % Rated(AC) voltage 50 to 60 Hz 275 V ~ Climatic category
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationCree XLamp CXA2 Studio LED
Cree XLamp CXA2 Studio LED Product family data sheet CLD-DS100 Rev 2A Product Description The XLamp CXA2 Studio LED is optimized for motion picture, studio and photography applications, delivering high
More informationReference Only Spec. No. JEFL243B 0003F-01 P 1/ 6
Spec. No. JEFL243B 0003F-01 P 1/ 6 DC Common Mode Choke Coil PLT09HN2003R0P1B Reference Specification 1. Scope This reference specification applies to DC Common Mode Choke Coil (PLT09H Series). 2. Part
More informationAluminum Capacitors Power Printed Wiring Style
FEATURES Polarized aluminum electrolytic capacitors, non-solid electrolyte Large types, cylindrical aluminum case, insulated Provided with keyed polarity Very long useful life: 000 h at 8 C Low ESR, high
More informationDVSA2800D Series HIGH RELIABILITY HYBRID DC-DC CONVERTERS DESCRIPTION FEATURES
HIGH RELIABILITY HYBRID DC-DC CONVERTERS DESCRIPTION The DVSA series of high reliability DC-DC converters is operable over the full military (- C to +12 C) temperature range with no power derating. Unique
More informationQT-Brightek SMD Super Thin Display Series Single Digit Display
QT-Brightek SMD Super Thin Display Series 0.56 Single Digit Display Part No.: QBSST56ZXX-R XX= Color Z= 1: Common Cathode Z = 0: Common Anode -R= Reverse Mount Product: QBSST56ZXX-R Date: January 16, 2017
More information5SP and 5SY Supplementary Protection UL 1077
Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic
More informationPRELIMINARY. CXB top-view product photo coming soon. features. Product Description. CLD-DS119 Rev 0. Product family data sheet
Cree XLamp CXB1816 LED Product family data sheet CLD-DS119 Rev 0 CXB top-view product photo coming soon Product Description The XLamp CXB1816 LED array expands Cree s family of high flux, multi die arrays
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationS95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationInterference Suppression PCX2 337 film capacitors
MKP RADIAL POTTED CAPACITORS Pitch 10.0/15.0/22.5/27.5mm QUICK REFERENCE DATA Capacitance range (E6 series) * 0.01to 3.3 Capacitance tolerance 10 %, 20 % Rated (AC) voltage 50 to 60 Hz 275 V ~ Climatic
More informationCat# LED High Bay
Cat# 71403 LED High Bay Model: 71403 Input Voltage Input Current Input Power Power Factor 100-277VAC 50/60HZ 1.7A Max 144 W PF 0.92 OVERALL LAMP Luminance 17371 LM PARAMETERS Luminous Efficiency 118 LM/W
More informationSHP-TS GroLux. SHP-TS 600W GroLux PRODUCT OVERVIEW
Patented arc tube delivers highest photosynthetic efficiency of any lamp in the world Performance maintained at an exceptional level due to improved structure of outer bulb Optimised for the highest Phytolumens
More informationPRELIMINARY. CXB top-view product photo coming soon. features. Product Description. CLD-DS121 Rev 0. Product family data sheet
Cree XLamp CXB1830 LED Product family data sheet CLD-DS121 Rev 0 CXB top-view product photo coming soon Product Description The XLamp CXB1830 LED array expands Cree s family of high flux, multi die arrays
More informationLED light engine / OLED LED compact. Uengine DLE G2 integrated ADV
Uengine DLE G2 integrated ADV uengine DLE Product description Module with integrated electronics For downlights Light engine operating with 23 V AC Luminous flux range from 1,24 2,43 lm High system efficacy
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More informationSquare. Fortimo LED. Datasheet. Fortimo LED Square 2500lm 8xx HV/LV2
Fortimo LED Fortimo LED Square 2500 8xx HV/LV2 Datasheet Fortimo LED Square Fortimo LED Square systems consist of white light LED modules with square outer dimensions delivering high energy efficiency
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive
More informationQUICK REFERENCE DATA. Pilkor components FEATURES APPLICATIONS
MKP RADIAL POTTED CAPACITORS Pitch 10.0/15.0/22.5/27.5 mm QUICK REFERENCE DATA Capacitance range (E6 series) * 0.01μF to 3.3μF Capacitance tolerance ±10 %, ±20 % Rated (AC) voltage 50 to 60 Hz 275 V ~
More informationSPECIFICATION SHEET :FH6-DUAL-3000L This Is An Original Product From Fulham Co., Inc ELECTRICAL DATA
Project Type Model # emarks Description :Firehorse Emergency Ballast for use with or without AC ballast designed to add emergency lighting when main AC power is interrupted for minimum of 90 minutes at
More informationLED modules LED linear / area
Module LLE G4 16mm 65lm ADV Module LLE advanced Product description Ideal for compact linear luminaires designs Homogenous illumination thanks to small package distance SELV module the single module has
More informationFL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5
F ballasts E PCA EXCE oneall lp Y II, 1 80 W EXCE Product description Processor-controlled ballast with y II inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via I or
More informationRecommended Testing Method of Aluminum Electrolytic Capacitor
Recommended Testing Method of Aluminum Electrolytic Capacitor Aluminum Electrolytic Capacitor (for LED Products) I. Endurance ) Testing device: Ripple power tester, Thermostatic drier, LCR digital electric
More informationPHOTODARLINGTON OPTOCOUPLERS
DESCRIPTION The CNX48U, HBX, and TIL3 have a gallium arsenide infrared emitter optically coupled to a silicon planar photodarlington. CNX48U HB HB2 HB255 HB3 TIL3 FEATURES High sensitivity to low input
More informationAC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC
AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC FEATURES Complying with IEC 60384-14 4 th edition High reliability Vertical (inline) kinked or straight leads Singlelayer AC
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationPHOTOTRANSISTOR OPTOCOUPLERS
DESCRIPTION The CNY7 series consists of a Gallium Arsenide IRED coupled with an NPN phototransistor. FEATURES CNY7-/2/3 are also available in white package by specifying -M suffix (eg. CNY7-2-M) UL recognized
More informationCNY17 Series. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards.
Optocoupler with Phototransistor Output Description The CNY7 series consists of a phototransistor optically coupled to a gallium arsenide infrared-emitting diode in a 6-lead plastic dual inline package.
More informationGENERAL PURPOSE 6-PIN PHOTOTRANSISTOR OPTOCOUPLERS
4N37 HA HA2 HA3 HA4 HA5 WHITE PACKAGE (-M SUFFIX) SCHEMATIC 2 3 NC PIN. ANODE 2. CATHODE 3. NO CONNECTION 4. EMITTER 5. COLLECTOR. BASE 5 4 BLACK PACKAGE (NO -M SUFFIX) DESCRIPTION The general purpose
More information4-PIN PHOTOTRANSISTOR OPTOCOUPLERS
PACKAGE HAA84 SCHEMATIC 4 COLLECTOR 4 2 3 EMITTER DESCRIPTION The HAA84 Series consists of two gallium arsenide infrared emitting diodes, connected in inverse parallel, driving a single silicon phototransistor
More informationWet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS
71400A GAS STATION Canopy Luminaire Wet Locations Use QPL ID # PL9D2UU8ZA41 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC OTHERS Model: Input Voltage Input Current Input Power
More informationISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER
ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationData Sheet. ASMT-QWBG, ASMT-QWBH 0.5 W Cool White Power PLCC4 Surface Mount LED. Description. Features. Applications
ASMT-QWBG, ASMT-QWBH 0.5 W Cool White Power PLCC4 Surface Mount LED Data Sheet Description The Avago Technologies ASMT-QWBx series 0.5W Cool White Power PLCC4 SMT LED lamps use InGaN chip technology and
More informationsolid state LED LED LED LED LED LED Light Emitting Diode: LED LED module Self - ballasted LED module Integral LED module
Light Emitting Diode: p-n solid state module Self - ballasted module Integral module Integral Self - ballasted module Built - in module Built - in Self - ballasted module Independent module Independent
More informationSiemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.
Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit
More informationReport No.: HZ p. (Lumens) Stabilization Time CRI (K)
Test Summary Sample Tested: ML2LA23LTRBNI827 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 73.6 1737.0 23.61 0.9872 CCT Stabilization Time CRI (K) (Light & Power)
More information佰鴻工業股份有限公司. DEVICE NUMBER:BWL-8Q5A21-K65 佰鴻工業股份有限公司
DATA SHEET DEVICE NUMBER: SHEET 1 2 3 4 5 6 7 CONTENTS DATE 2010.10.18 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Preliminary 台北縣板橋市和平路 19 號 3 樓 APPROVED DRAWER 羅劉 3F., No. 19, Ho Ping Road, Pan Chiao City, Taipei, Taiwan,
More informationCree XLamp CXB2530 LED
Cree XLamp CXB2530 LED Product family data sheet CLD-DS122 Rev 0B Product Description The XLamp CXB2530 LED Array is a member of the second generation of the CXA family that delivers up to 30% higher efficacy
More informationCNY64/ CNY65/ CNY66. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards
Optocoupler with Phototransistor Output Description The CNY64/ CNY65/ CNY66 consist of a phototransistor optically coupled to a gallium arsenide infrared-emitting diode in a 4-lead plastic package. The
More informationresistance in the circuit. When voltage and current values are known, apply Ohm s law to determine circuit resistance. R = E/I ( )
DC Fundamentals Ohm s Law Exercise 1: Ohm s Law Circuit Resistance EXERCISE OBJECTIVE When you have completed this exercise, you will be able to determine resistance by using Ohm s law. You will verify
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL07860-001B BXSPR-HO-xx-5SH-60W-40K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size
More informationEECE 2150 Circuits and Signals Final Exam Fall 2016 Dec 16
EECE 2150 Circuits and Signals Final Exam Fall 2016 Dec 16 Instructions: Write your name and section number on all pages Closed book, closed notes; Computers and cell phones are not allowed You can use
More informationUNISONIC TECHNOLOGIES CO., LTD LM78XX
UNISONIC TECHNOLOGIES CO., LTD LM78XX 3-TERMINAL 1A POSITIVE VOLTAGE REGULATOR 1 TO-220 DESCRIPTION The UTC LM78XX family is monolithic fixed voltage regulator integrated circuit. They are suitable for
More informationLED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE STARK-CLE EM STARK-CLE EM-SO Ø315
D Product description Ideal for ceiling-mounted and wallmounted luminaires Based on annular and compact fluorescent lamps Efficiency of the module up to 127 lm/w SO version is compatible with SWITCH Sensor
More informationAxial Leaded Multilayer Ceramic Capacitors for Automotive Applications Class 1 and Class 2, 50 V DC, 100 V DC, 200 V DC
Axial Leaded Multilayer Ceramic Capacitors for Automotive Applications Class 1 and Class 2, 50 V DC, 100 V DC, 200 V DC FEATURES AEC-Q200 qualified with PPAP available High reliability MLCC insert with
More informationGreek Letter Omega Ω = Ohm (Volts per Ampere)
) What is electric current? Flow of Electric Charge 2) What is the unit we use for electric current? Amperes (Coulombs per Second) 3) What is electrical resistance? Resistance to Electric Current 4) What
More information