SILVER CAST IRON BOILERS. Pennco SILVER makes Simple Comfort, Affordable.

Size: px
Start display at page:

Download "SILVER CAST IRON BOILERS. Pennco SILVER makes Simple Comfort, Affordable."

Transcription

1 SILVER ST IRON OILERS Pennco SILVER makes Simple omfort, ffordable.

2 S I LVER ST IRON OILERS f f o r d a b l e H y d r o n i c H e a t i n g Pennco S I LV E R While today s tough economy makes it harder than ever to meet basic needs simple comfort shouldn t be a sacrifice. That s why Pennco now offers SILVER a full line of affordable heating products. merican made Pennco SILVER is designed, tested and assembled to ensure customers get the very best in home heating comfort and value. Financing is available to those who qualify through GE Money. pply on-line today at: dded peace-of-mind is available in the form of five and ten year omfort Plus Extended Parts & Labor Warranties which can be included in the financed cost. E ff i c i e n c y Pennco SILVER features economical, mostly mid-efficiency heating solutions. Pennco understands that no one really plans to replace their heating system and not everyone can afford to upgrade to high efficiency. If your home heating appliance is more than 15 years old, even a mid-efficiency upgrade could save you money on your utility bills. S e l e c t i o n Pennco SILVER features a wide range of heating equipment suitable for residential and light commercial applications. 2

3 15 Series FS Series KSW Series 16 Series KS Series 41J Series Hotline o i l e r S e l e c t i o n G u i d e Model pplication Fuel Efficiency apacity ombustion Venting 15 Residential Hot Water oiler Gas Mid-Efficiency tmospheric himney MH FS Residential Hot Water oiler Gas Mid-Efficiency Fan ssist himney MH or Side-Wall KSW Residential Hot Water oiler Oil Mid-Efficiency tmospheric himney MH 16 Residential Steam oiler Gas Mid-Efficiency tmospheric himney MH KS Residential Steam oiler Oil Energy Star tmospheric himney MH 41J Light ommercial Hot Water Gas Mid-Efficiency 300-3,000 MH tmospheric himney or Steam oiler Hotline Residential/Light ommercial N/ * Gal. N/ N/ Indirect Hot Water Heater Efficiency varies based on boiler efficiency and other factors. * 3

4 R e s i d e n t i a l H o t W a t e r o i l e r s 15 S e r i e s Gas-Fired Hot Water oiler System Features The Pennco 15 Series oiler has been designed with features making it the ideal home heating solution. With quality features such as an advanced heat exchanger design, greater TU input per sectional size and optional electronic ignition, the 15 Series can achieve fuel efficiencies up to 82% FUE. Quality Heat Exchanger Design The 15 Series f e a t u res a robust cast iron heat exchanger with greater weight per section resulting in higher efficiencies and longer boiler life. The sections are connected with cast iron push nipples, which expand and contract at the same rate as the sections ensuring a water tight seal. dditional sizes are available and when utilized in a seven section configuration, the 15 Series can reach nearly 300 MH input. High Efficiency The 15 Series provides annual fuel utilization efficiency up to 82% as certified by the US Department of Energy testing standards. Hi-Limit ontrol The Honeywell hi-limit control has been separated from the circulator relay for ease of serviceability and to reduce potential service parts costs. Easy Installation and Maintenance compact design, low profile draft hood and top supply piping connections allow for easier installation. The pilot is mounted to the front of the burner base. 1 1/4" Supply 3 9/16" "" "" "" "F" "D" 25 5/16" "E" 4" oiler Jacket a s t - I ron oiler attery High Limit ontro l Vent Damper Relay ombination Pre s s u re Te m p e r a t u re Gauge irculator Stainless Steel urners utomatic Vent Damper ombination 24-Volt Gas ontrol includes: utomatic Gas, Gas Pressure Regulator, utomatic Pilot, Safety Shut Off, Pilot Flow djustment, Pilot Filter.S.M.E. Relief Drain Optional Equipment: Intermittent Electric Ignition Pilot System ombustible Floor Kit Taco irculator Pump. Note: Propane option available. 3 1/2" 1 1/4" Return 1 1/4" 5 7/8" ME# 39-86E Vol VIII Pump Size. G.. H e a t i n g I = = R N a t u r al Dimensions (Inches) N u m b e r F U E F U E o i l e r S u p p l y I n p u t a p a c i t y Net Output G a s o f Elec. Ign. Std. Pilot N u m b e r & Return tu/h r. * tu/h r. * tu/h r. * I n l e t u rn e r s & Damper & Damper D E F Ta p p i n g s , , , / 2 " " % % , , , / 2 " " % % , , , / 2 " " % % , , , / 2 " " % % , , , / 2 " " % % , , , / 2 " " % % , , , / 2 " " % % , , , / 4 " " % % , , , / 4 " " % % 4 * For elevations above 2000 feet, ratings should be reduced at a rate of 4% for each 1000 feet above sea level. For equivalent square feet of radiation, divide I==R output by 150. Propane gas Inlet, all units, 1/2".S.. ertified For Natural Gas Or Propane Tested For 100 LS. SME Working Pressure

5 R e s i d e n t i a l H o t W a t e r o i l e r s FS S e r i e s Gas-Fired Hot Water oiler Side-Wall or himney Vent SME Relief Supply ombination Limit & Relay ontrol 23 1/4" lower 3" ssembled boiler with insulated jacket 3" x 4" galvanized increaser fitting and silicone sealant to adapt 3" fan outlet to 4" vent pipe for chimney venting ombination high limit control and circulator relay 24 volt transformer to power gas control system Flame rollout safety shut-off fuse link (rollout switch) Pressure switch for proving air flow ombination pressure/temperature gauge (packed separately) 1 1 /4" circulator 3 /4" boiler drain valve 30 lb. SME relief valve ompletely installed and wired gas control system with burners and manifold, consisting of: Stainless steel burners utomatic redundant combination gas valve, 24 volt, with pilot filter Pressure regulator Intermittent Pilot ontrol, continuous re-try, 100% shut-off for natural & propane gas ombination pilot/burner/electrode/flame sensor omplete installation instructions Optional Equipment: ombustible floor plate 24"x 30" for 2-5 section; 3 0"x 30" for 6 & 7 section T j e rnl und VH-1-3" side wall vent hood T j e rnl und VH-1-4" side wall vent hood P ropane gas to natural gas conversion kits Natural gas to propane gas conversion kits 1-1/4"NPT Drain Manifold LEFT SIDE FRONT RIGHT SIDE ME# E Vol. III D O E n n u a l o i l e r N u m b e r G H e a t i n g I = = R F u e l M o d e l o f I n p u t a p a c i t y Net Rating Wi d t h E ff i c i e n c y N u m b e r S e c t i o n s ( M H ) ( M H ) ( M H ) ( F U E ) FS " 84.4 FS " 83.4 FS " 83.0 FS " 82.7 FS " 82.3 FS " 82.0 MH = 1,000 tuh tuh = ritish Thermal Unit Per Hour FUE and Heating apacity are based upon D.O.E (Department of Energy) test procedure. * onventional venting through a lined chimney use 4" Flue dapter provided. * Through the wall venting Sizes use 3" Stainless Steel Vent Pipe. Sizes 6-7 use 4" Stainless Steel Vent Pipe (not included).s.. ertified For Natural Gas Or Propane Rollout Switch 29" Return Pressure Switch Intermittent INTERMITTENT Pilot ontrol PILOT ONTROL Gas Tested for 50 lbs. SME Working Pressure KSW S e r i e s Oil-Fired Hot Water oiler ssembled boiler with insulated jacket ombination high limit control and circulator relay, on boilers without optional tankless heater coil ombination high limit control, low limit control and circulator relay, on boilers with optional tankless heater coil Target wall (vacuum formed refractory ceramic fiber) ombination pressure/ temperature gauge arometric draft control 6" 1 1 /4" circulator 3 /4" boiler drain valve 30 lb. SME relief valve eckett FG series oil burner equipped with nozzle, primary control, interrupted duty ignition, PS motor and clean cut (solenoid) pump Model No. Model No. N u m b e r **H e a t i n g w i t h w i t h o u t o f I n p u t a p a c i t y Tankless oil Tankless oil S e c t i o n s *M H* *M H* 36" Gauge 1 1/4" Return 1 1/4" Supply ontrol quastat ontrol (with oil) Tankless Heater 1/2" N.P.T. 19 5/8" 9" FRONT VIEW SIDE VIEW K VIEW N E T F i r i n g I = = R R a t e Rating *M H* * G P H 3/4" SME Relief Ta n k l e s s D I M E N S I O N S H e a t e r h i m n e y ( I n c h e s ).F.U.E. a p a c i t y S i z e G P M * 3K.60 3K x8x / / K.75 3K x8x / / K1.00 3K x8x / / K.90 4K x8x / K1.25 4K x8x / K1.50 4K x8x / p p ro x. S h i p p i n g We i g h t 5K1.20 5K x8x / K1.75 5K x8x / K2.00 5K x8x / * MH = 1,000 tu per hour tu = ritish Thermal Unit * * Heating capacity based on 13% O2 with a ÑO.02î W.. draft o v e rf i re, and a #1 smoke or less. Testing was done in accordance with the D.O.E. (Department of Energy) test pro c e d u re. GPH = Gallons per hour oil at 140,000 tu per gallon Gallons of water per minute, heated from 40 to 140, with 200 boiler water temperature, intermittent draw..f.u.e. = nnual Fuel Utilization Efficiency based on D.O.E. test procedure. s an Energy Star Partner, Pennco has determined that this product meets Energy Star guidelines for energy efficiency. Tested for 50 lbs. SME Working Pressure 5

6 R e s i d e n t i a l S t e a m o i l e r s 16 S e r i e s Gas-Fired Steam oiler ssembled boiler with insulated jacket Two 2 1 /2" supply tappings and two 2 1 /2" return tappings Integral draft diverter built into jacket 24 volt, 40V transformer Pressure limit control E l e c t ronic probe type low water cut off Flame rollout safety shut-off fuse link and blocked vent safety shut-off switch Glass water level gauge Steam pressure gauge 3 /4" boiler drain valve 15 lb. SME pop safety valve Two 2 1 /2" s q u a re head pipe plugs t o plug unused supply and re t u rn tappings Vent damper ompletely installed and wired gas control systems with burners and manifold, consisting of: utomatic redundant combination gas valve, 24 volt, with pilot filter Electronic Ignition Only: Intermittent Pilot ontrol, continuous re-try,100% shut-off ombination pilot/burner/ electrode/flame sensor Standing Pilot Only: Pilot burner and thermocouple Optional Equipment: ombustible floor plate for 3-6 section; for 7-9 section Electronic water feeder Float type low water cut-off in place of probe type Natural to propane conversion kit (when ordering kit, please provide serial number of boiler to be converted) SME Pop Safety 29" 12 1/4" 2-1/2" NPT Vent Damper Pressure Gauge Water Line Low Wa t e r u t - O ff 36 3/8" Transformer 26 1/2" 4 3/4" 2-1/2" Glass P ro b e Low Gauge S86 Water 24" ut-off Gas Line OILER UNIT NUMER N TURL GS P R O PNE GS D I M E N S I O N S ( i n. ). F. U. E. ME# E ont. Pilot E/I Pilot N u m b e r G H e a t i n g N E T N E T G H e a t i n g N E T N E T H S D H S I D w i t h w i t h o f I n p u t a p a c i t y I = = R I = = R I n p u t a p a c i t y I = = R I = = R F l u e w i t h w i t h D a m p e r D a m p e r S e c t i o n s M H M H M H * Sq. Ft. EDR M H M H M H * Sq. Ft. EDR D i a m e t e r Wi d t h D a m p e r D a m p e r 1603HSD 1603HSID / HSD 1604HSID / HSD 1605HSID / HSD 1606HSID HSD 1607HSID / HSD 1608HSID / HSD 1609HSID / For altitudes above 2,000 feet, ratings should be re d u c e d at a rate or 4% for each 1,000 feet above sea level. MH = 1,000 tu per hour tuh = ritish Thermal Unit per hour Heating capacity based on D.O.E. (Department of Energy) standard s * dd 5-1/2 " to height for vent damper EDR = Equivalent Direct Radiation Gas Tested for 50 lbs. SME Working Pressure K S S e r i e s Oil-Fired Steam oiler rated ast-iron oiler Flush Jacket Swing-Out urner Door lean ut eckett urner Target Wall /Liner SME Relief Water Level Gauge Steam Pressure Gauge Steam Pressure ontrol E l e c t ronic Low Water ut-off Drain Wiring Harness urner Electric Disconnect Plastic over Supply Tappings (Qty. 2-2") Return Tapping 1 1 /2" Skim Port Tankless Water Heater Option: Tankless Hot Water oil Limit ontrol 6 ME# E I = = R I = = R D I M E N S I O N S Tankless Wa t e r Oil urn e r D. O. E. Net Ratings 3, 4 Heater apacities o i l e r o i l e r I n p ut 2 H e a t i n g Pump N o z z l e I n t e rm i t t e n t Wa t e r M o d e l a p a c i t y S t e a m Sq. Ft. P re s s u re F u rn i s h e d. F. U. E. Length of F ront of Jkt. t o Diameter of Draw G.P. M. o n t e n t N u m b er 1 G. P. H. M H 4 M H 4 M H S t e a m P S I 140 PSIG 5 R a t i n g Flush Jacket /L of Flue Out Flue Outlet (Model L-24) G a l s. *KS0365* ** 1 1 KS *KS4100* KS KS KS H KS H KS KS * Indicates an Energy Star efficient Product Explanation Notes: Electronic Low Water ut-off Oil urner 1. dd suffix T to denote boiler with tankless heater. 2. I==R burner capacity is based on an oil heating value of 140,000 tu/gal. and with 13% O2. 3. Net ratings based on 170 F temperature in radiators and include 33% allowance for normal piping and pick-up load. onsult manufacturer for unusual piping and pick-up re q u i rements. 21 7/8" 9 1/32" Pressure ontrol 35 3/4" 16" SME Pressure Relief 4. For altitudes above 2,000 ft., ratings may be reduced at the rate of 4% for every 1,000 ft. above sea level. 5. Nozzle sizes with an H designation are Hago brand, all others are Delevan. 6. The electrical service is120 Vo l t s, 15 mps,60 Hz. vailable on request. ** Tested For 15 LS. SME Working Pressure

7 o m m e r c i a l H o t W a t e r & S t e a m o i l e r s 4 1 J S e r i e s Gas-Fired Hot Water or Steam Modular oiler Electronic Ignition ase ase Fire Door urner Orifice Manifold Main and Pilot urner Electronic Pilot Gas Intermittent Pilot Module High Gas Pre s s u re Switch Water Trim Package: Limit ontrol (two required on units 2,500,000 TU and larger) Pressure Temperature Gauge Relief Drain omplete Jacket ssembly Steam Trim Package: Low Water ut-off Glass Gauge Set Pop Safety Steam Gauge Pressure Limit Drain omplete Jacket ssembly 41J Series oiler ases are pre a s s e m b l e d at the factory with burner manifold, burn e r orifices, gas valves, electronic ignition and pilot installed, ready for field installation of the pre-tested sections and appro p r i a t e p a c k a g e s. Plug 'N Play Harness and Junction ox Individual base and junction box controls are designed for easy installation with Plug 'n Play h a rnesses. The entire boiler links together in a "snap". color-coded factory supplied harn e s s eliminates wiring erro r s. Modular Efficiency Most commercial boilers are either all-on or all-off. The 41J boiler when used in conjunction with the optional rgo M ontrol Kit will stage fire the individual bases. Depending on model, capacities as low as 11% of full load can be obtained for optimal perf o rm a n c e. The optional M ontrol Kit adjusts the water temperature for increased fuel economy. The control balances section run time for i n c reased re l i a b i l i t y. The modular base design allows for built in back-up to reduce no heat situations. SD1 Option 41J boilers are available with a SD1 option to comply with SD1 standards where required by public building code. The SD1 option provides the increased number of controls and safety devices required to meet SD1 standards. 80% Thermal Efficiency * If opening F is to be used for something other than the Pop Safety or Pressure Relief, or the Safety/Relief is larger than 1 ", t h e Safety/Relief must be installed in the Header Piping as near to the boiler as possible. 41J Series Right-End and Left-End Tappings Data. G... G.. ase Size & h i m n e y Net I==R Ratings F l u e o i l e r Input (1) Output (1) Flue Outlet Size (6) o l l e c t o r M o d e l S t e a m S t e a m Wa t e r Size To tu Mbh tu Mbh I.D. x Ht. Sq. Ft. (3) tu Mbh tu Mbh 8 in. 10 in. 12 in. h i m n e y " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' " x 20' Explanation Notes: 1. Ratings are at sea level to 2,000 feet. For altitudes above 2,000 feet, reduce all ratings 4% for each 1,000 feet above sea level. 2. Ratings in square feet are computed at 240 tuh/square foot for steam boilers. 3. Ratings based on 33,500 tuh per horsepower. 4. Pressure drop based on given flow from a single outlet and returning to a single inlet at the opposite end of the boiler. D 5. himney sizes shown are one option based on a typical venting system, and sized according to the National Fuel Gas ode, assuming Type double wall vent and vent connectors, other venting system designs are acceptable as shown on Flue onnection nd Venting section of the installation manual. For further chimney design and sizing information, consult the National Fuel Gas ode, NSI Z223.1/NFP 54-latest revision, or SHRE-1996 HV Systems and Equipment Handbook, hapter 30, himney, Gas Vent, and Fireplace Systems, or the Standard for himneys, Fireplaces, Vents, and Solid Fuel urning ppliances. NFP 211 latest revision. Follow standard engineering practice. F G E O P E N I N G S I Z E S T E M WT E R 4 " Supply and Return Supply and Return 1 /2" P r i m a ry LWO and Gauge Glass Set P re s s u re Dro p H o r s e p o w e r T h ru Water oiler (5) G ro s s Output (4) I n. G P M Wa t e r P l u g g e d 1 1 /2" Drain, Right End Drain, Left End 3 /4" Drain, Right End Drain, Right End D 1 /2" P l u g g e d Limit ontro l E 1 " c c e s s o r i e s c c e s s o r i e s * F * 1 " Pop Safety Va l v e P re s s u re Relief Va l v e G 3 /4" Plugged or Electro n i c ( P robe Type) LW O P l u g g e d Tested for 100 lbs. SME Working Pressure 7

8 R e s i d e n t i a l H o t W a t e r H e a t e r s P e n n c o Indirect Hot Water Heater o m m e rcial Quality and apability. Residential ff o rd a b i l i t y Domestic Water Hot and old Side onnection HL 30SK, HL 40SK, HL 50SK. Hot Only Top onnection HL 80SK,H L1 1 9 S K. old Only ottom/side HL 80SK, HL1 1 9 S K. oil onnections Include dielectric unions for both inlet and outlet 2 Foam Insulation Heavy-Duty Steel Jacket Replaceable Extra-Thick Magnesium node Rod o rrosion Resistant Porc e l a i n - c o a t e d Enamel Smooth oil and Interior Tank Wa l l s Immersion quastats standard on all models S u rface-mounted Therm o s t a t Self-cleaning Drain Va l v e F a c t o ry Installed T&P Va l v e NOTES: Potable outlet water temperature at 135 F as per D.O.E. oiler output should be at least 74,000 TU/h. First Hour Rating oil Output (tu/hr) Hot Outlet/ node Rod 3/4" NPT quastat Drain node Rod old Inlet 3/4" NPT T&P Relief From oiler S u p p l y, 1" NPT Models HL30SK, HL40SK, HL50SK Models HL80SK, HL119SK M o d e l S t o r a g e D I M E N S I O N S ( i n c h e s ) S h i p p i n g N u m b e r a p a c i t y D E F G H We i g h t HL30SK 30 Gal. 22" " " " " 6 1 2" 4 1 2" N/ 180 lbs. HL40SK 38 Gal. 22" " " " " 6 1 2" 4 1 2" N/ 226 lbs. HL50SK 45 Gal. 22" " " " " 6 1 2" 4 1 2" N/ 231 lbs. HL80SK 75 Gal. 24" " " 33" " 8" 5" 5" 297 lbs. HL119 S K 110 Gal. 28" " " " " 8 3 4" 5" 6 1 2" 397 lbs. MODEL F / 6 GPM* F / 10 GPM* F / 12 GPM* F / 6 GPM* F / 8 GPM* F / 10 GPM* F / 12 GPM* To oiler R e t u rn, 1" NPT F D quastat E node Rod H old Inlet 1" NPT Hot Outlet 1 1/2" NPT node Rod T&P Relief Va l v e From oiler S u p p l y, 1" NPT D rain Va l v e To oiler R e t u rn 1" NPT G F D H L 3 0 S K 53,000 57,000 59,000 67,000 69,000 71,000 73,000 H L 4 0 S K 69,000 84,000 92,000 88,000 96, , ,000 H L 5 0 S K 69,000 84,000 92,000 88,000 96, , ,000 H L 8 0 S K 76,000 91,000 98,000 97, , , ,000 H L S K 76,000 91,000 98,000 97, , , ,000 NOTES: First Hour Rating = First Draw + ontinuous Draw * oil Input (temperature, flow rate). Ratings based on 77 F rise with 58 F inlet potable water. ll data obtained through testing in accordance with GM INDIRET-FIRED WTER HETER TESTING STNDRD IWH-TS-1_MRH 2003 dditional oiler Model Notes: Selection of water boiler size should be based upon Net I==R Rating being equal to or greater than the calculated heat loss of the building. Selection of steam boiler size should be based upon Net I==R Steam Rating being equal to or greater than the installed radiation in square feet EDR. 1 5 F S K S W K S J ll boilers are design-certified for installation on non-combustible floors. For installation on any combustible floor, use combustible floor kit. If combustible floor kit is unavailable refer to installation manual for specific instructions for that model. 15 F S K S W K S J The ratings marked Net I==R Ratings represent the portion of the heat output that can be applied to heat the radiation or terminal units. Ratings based on selection factors recommended by Hydronics institute for piping and pickup. Net water boiler ratings are based on an allowance of 1.15, and net steam boiler ratings are based on an allowance of For water applications with high piping and pickup requirements, use steam rating. Ratings based on selection factors recommended by Hydronics institute for piping and pickup. Net steam boiler ratings are based on an allowance of Recommended chimney height 20 feet. In special cases where conditions permit, chimney height may be reduced. Refer to the latest revision of National Fuel Gas ode. Electrical service to be 120 volts, 15 amps, 60Hz3. Manufacturer should be consulted on installations having other than normal piping and pickup requirements. Specifications and dimensions for all Pennco SILVER models are subject to change without notice. n ISO ertified ompany Dwyer venue, Utica, New York Phone: Fax: info@ecrintern a t i o n a l. c o m Web: www. p e n n c o b o i l e r s. c o m US ontractor ssistance: PN REV 4/09

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace 80% AFUE Heating Input: 70,000 115,000 BTU/h ComfortNet -Compatible Two-Stage, Variable-Speed Gas Furnace Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve operates

More information

Chimney Sizing. Project Name: Location: Type Appliance: Hot Water Heater Incinerator. LP Gas #2 Oil #6 Oil Wood/Coal Waste (Type ) Appliance Input:

Chimney Sizing. Project Name: Location: Type Appliance: Hot Water Heater Incinerator. LP Gas #2 Oil #6 Oil Wood/Coal Waste (Type ) Appliance Input: Chimney Sizing Project Name: Location: Type Appliance: Type Fuel: Appliance Input: Boiler Hot Water Heater Incinerator Natural Gas LP Gas #2 Oil #6 Oil Wood/Coal Waste (Type ) BTU Hp Lbs/hr Height Above

More information

PARTS LIST GAS BOILERS MODELS: CG320 (E) CG325 (E) CG330 (E)

PARTS LIST GAS BOILERS MODELS: CG320 (E) CG325 (E) CG330 (E) PARTS LIST GAS BOILERS MODELS: CG320 (E) CG325 (E) CG330 (E) CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE: (416) 746-2358, FAX: (416) 746-8324

More information

DGCU165-5B 36 W. Five-Burner Cooktop

DGCU165-5B 36 W. Five-Burner Cooktop Standard Features & Accessories All models include Dimensioned fit the majority of similarly sized cookp cuuts Sealed burners with brass flame ports and porcelain/cast iron burner caps Burners mounted

More information

SRP RESIDENTIAL GARAGE HEATERS

SRP RESIDENTIAL GARAGE HEATERS SRP RESIDENTIAL GARAGE HEATERS GR RESIDENTIAL GARAGE HEATERS ARE SHIPPED FULLY ASSEMBLED C / W THERMOSTAT, WALL THIMBLE, 8 INTAKE / EXHAUST PIPES, GAS FLEX CONNECTOR AND CEILING SUSPENSION HARDWARE. BOTH

More information

ClimateMaster s Tranquility 22. Raj Hiremath Director of Residential Marketing

ClimateMaster s Tranquility 22. Raj Hiremath Director of Residential Marketing ClimateMaster s Tranquility 22 Raj Hiremath Director of Residential Marketing 1 CLIMATEMASTER Industry leader since 1950 s First to introduce 2-stage 27 EER unit First to introduce Outdoor split system

More information

98 Series Backpressure Regulators and Relief Valves

98 Series Backpressure Regulators and Relief Valves 9 Series Backpressure Regulators and Relief Valves Bulletin.:9 November 09 W TYPE 9H W TYPE 9LD Figure. Typical 9 Relief Valves Introduction W TYPE 9HD The 9 Series (Figure ) is used for backpressure or

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

10-year industry best core warranty. 2-year warranty on balance of unit.

10-year industry best core warranty. 2-year warranty on balance of unit. MODEL FEATURES MERV-8 filters Fully insulated case Large cores for high efficiency No condensate pan or drain required AHRI Certified Rainhood included Access door for easy maintenance and Cleaning Integral

More information

Cartridge Valves Technical Information. Quick reference

Cartridge Valves Technical Information. Quick reference Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...

More information

Protective Coatings: Non-lead orange paint RAL red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153.

Protective Coatings: Non-lead orange paint RAL red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153. Technical Services: Tel: (66) 500-76 / Fax: (01) 71-7317 www.grinnell.com Grinnell Mechanical Products Grooved Fittings, Ductile Iron & Fabricated Steel General Description Grooved fittings provide an

More information

FVBSS fixed volume bottle

FVBSS fixed volume bottle N FVBSS fixed volume bottle Sampling System The SENSOR Fixed Volume Bottle Sampling System (FVBSS) provides a repeatable fixed volume of sample during each sampling process without stopping flow of the

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS GMV95/GV9 SERIES UP TO 95% FUE MULTI-POSITION, 2-STGE/VRILE-SPEE GS FURNE HETING PITY: 46,000 115,000 TUH GMV95 Models Qualify for a $200 Tax redit GV9 Models Qualify for a $50 Tax redit Standard Features

More information

Parts List with Exploded Views

Parts List with Exploded Views Parts List with Exploded Views Dual Fuel- Series Dual Fuel Range Top Parts List for Model DF Ref # Part # Description 0 Grate, Burner W/Rubber Pad 0 Burner Cap Assy, Sml 0 Burner Head 0 Venturi, Small

More information

PARTS LIST GAS BOILERS MODELS:

PARTS LIST GAS BOILERS MODELS: PARTS LIST GAS BOILERS MODELS: CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) CG330 (E) southbend A MIDDLEBY COMPANY 1100 Old Honeycutt Fuquay-Varina, NC 27526 (919) 552-9161 FAX (919) 552-9798

More information

BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton

BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton BV SERIES VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton MAGIC AIRE BV SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.

More information

Repair Parts List DUEL FUEL RANGE MODEL NUMBER SVD48600BC. When requesting service or ordering parts, always provide the following information:

Repair Parts List DUEL FUEL RANGE MODEL NUMBER SVD48600BC. When requesting service or ordering parts, always provide the following information: Repair Parts List DUEL FUEL RANGE MODEL NUMBER SVD48600BC When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description

More information

TOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES Jacques Chaurette p. eng., June 2003

TOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES Jacques Chaurette p. eng.,   June 2003 TOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES Jacques Chaurette p. eng., www.lightmypump.com June 2003 Figure 1 Calculation example flow schematic. Situation Water at 150 F is to be pumped from a

More information

Convert cubic inches to cubic feet: Cubic inches 1728 (12 x 12 x12 = 1728)

Convert cubic inches to cubic feet: Cubic inches 1728 (12 x 12 x12 = 1728) Interior Volume of the Kiln: Sprung or Roman Arch: 12.5 CF = W x L x ( H Side wall + 2/3 of the arch rise) 37.5 Test kiln=? 31.5 Convert cubic inches to cubic feet: Cubic inches 1728 (12 x 12 x12 = 1728)

More information

REPAIR PARTS. GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS951155DXAB.

REPAIR PARTS. GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS951155DXAB. REPAIR PARTS GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS55DXAB Made in the USA by: Goodman Manufacturing Company, L.P. 2550 North Loop West, Suite 400

More information

REPAIR PARTS. AMH95 Amana brand 95% Hybrid Furnace AMH950453BXAA AMH950703BXAA AMH950704CXAA AMH950904CXAA AMH950905DXAA AMH951155DXAA

REPAIR PARTS. AMH95 Amana brand 95% Hybrid Furnace AMH950453BXAA AMH950703BXAA AMH950704CXAA AMH950904CXAA AMH950905DXAA AMH951155DXAA REPAIR PARTS AMH95 Amana brand 95% Hybrid Furnace AMH950453BXAA AMH950703BXAA AMH950704CXAA AMH950904CXAA AMH950905DXAA AMH9155DXAA Amana is a trademark of Maytag Corporation and used under license to

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

0T 0TS S T TS T TS T TS 0T T T T T T 6T T TS 6T 6TS T TS 6T 6TS 6T 6TS 6T 6TS Frame.. 6. 6 6... 6.... B 6 6... A..... 0..0... 6.... 6.....06 6.66.. 6.0.....6 0... C 6..0 6. 6....... E.. D....... F 6............

More information

Model 33SZ Basic Unit OPTIONAL FILTER RH COIL CONNECTION PRIMARY/ DEDICATED OUTDOOR AIR MULTI-POINT FLOW SENSOR 5 3/4" (146)

Model 33SZ Basic Unit OPTIONAL FILTER RH COIL CONNECTION PRIMARY/ DEDICATED OUTDOOR AIR MULTI-POINT FLOW SENSOR 5 3/4 (146) DESRIPTION: Sensible cooling coil on the induced air inlet handles zone sensible load. Opposite side to controls location. luminum ripple fins (10 PI) and 1/" (13) copper tubes. and of coil connection

More information

REPAIR PARTS. GMEC 96% ECM Up Flow Furnace

REPAIR PARTS. GMEC 96% ECM Up Flow Furnace REPAIR PARTS GMEC 96% ECM Up Flow Furnace GMEC960302BNAA GMEC960302BNAB GMEC960402BNAA GMEC960402BNAB GMEC960603BNAA GMEC960603BNAB GMEC960803BNAA GMEC960803BNAB GMEC961004CNAA GMEC961004CNAB GMEC961205DNAA

More information

PARTS MANUAL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL

PARTS MANUAL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER

More information

McQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017

McQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017 Replacement s List No. 055206700 Revision B 02/2017 McQuay Water Source Heat Pump VF, VG, VP 240-390 Vintage E, F, G Last Manufactured: 1992 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

ENVIRONMENTALLY SOUND R 410A REFRIGERANT

ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,

More information

nufacturing Company, L.P San Felipe, Suite

nufacturing Company, L.P San Felipe, Suite REPAIR PARTS GMVC 96% ECM Up Flow Furnace GMVC960403BNAA GMVC960603BNAA GMVC960803BNAA GMVC960804CNAA GMVC961005CNAA GMVC961205DNAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com

More information

Service Parts. AMV9*XA Upflow/Horizontal/Two- Stage/Variable Speed 90% AFUE Gas Furnace. Models and manufacturing numbers in this manual

Service Parts. AMV9*XA Upflow/Horizontal/Two- Stage/Variable Speed 90% AFUE Gas Furnace. Models and manufacturing numbers in this manual Service s AMV9*XA Upflow/Horizontal/Two- Stage/Variable Speed 90% AFUE Gas Furnace AMV90453BXA AMV90704CXA AMV90905DXA AMV91155DXA Models and manufacturing numbers in this manual P1257401F P1257403F P1257405F

More information

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS CADB/T-N Series

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS CADB/T-N Series FILTERS F7 Compact heat recovery unit with cross-flow heat exchanger in 9 sizes from 500 m 3 /h to 8.350 m 3 /h. The casing is made from aluminium profile frame with double skinned 25 mm steel panels with

More information

Accumulators Virginia KMP Suction Line Accumulators

Accumulators Virginia KMP Suction Line Accumulators Accumulators Virginia KMP Suction Line Accumulators The Virginia KMP suction line accumulator's purpose is to prevent excessive quantities of liquid refrigerant and oil from returning to the compressor.

More information

GB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY

GB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY TECHNICAL SPECIFICATIONS GB5BM Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The GB5BM Series of air handlers, when combined with our heat pump or air conditioner,

More information

Cookers. Always fresh. Always delicious.

Cookers. Always fresh. Always delicious. Cookers Always fresh. Always delicious. Gas Cookers WGC576DX3X (220V, 50/60Hz) Stainless Steel Double Oven 1 Large Center Burner Electronic Ignition with 3 Rack Positions in Lower Oven 1 Fixed Oven Rack

More information

PARTS MANUAL Gas Furnace F9MAC, G9MAC

PARTS MANUAL Gas Furnace F9MAC, G9MAC Gas Furnace F9MAC, G9MAC Safety Labeling and Signal Words DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal

More information

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator

More information

(HSI) LIMITED WARRANTY

(HSI) LIMITED WARRANTY ama The Payne PG8MAA/JAA 80% AFUE Gas Furnaces feature 4-way multipoise design and through-the-furnace downflow venting. The PG8MAA/JAA furnaces are approved f use with natural propane gas, and the PG8JAA

More information

REPAIR PARTS. GMV9* Variable Speed Furnace

REPAIR PARTS. GMV9* Variable Speed Furnace REPAIR PARTS GMV9* Variable Speed Furnace GMV90703BXBA GMV90905CXBA GMV155DXBA GMV950453BXBA GMV950453BXBB GMV950704CXBA GMV950704CXBB GMV950905DXBA GMV950905DXBB GMV9155DXBA GMV9155DXBB GMV9155DXBC Goodman

More information

Clausing Industrial, Inc. Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

Clausing Industrial, Inc. Variable Speed 20 Single and Multi-spindle, Belt Drive Industrial Drill Presses www.clausing-industrial.com Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses Clausing Industrial, Inc. Two Speed Variable Speeds 150-2000rpm Variable Speeds 200-1300rpm

More information

REPAIR PARTS. GDH8 80% Two-Stage Hybrid Dedicated Downflow Gas Furnace

REPAIR PARTS. GDH8 80% Two-Stage Hybrid Dedicated Downflow Gas Furnace REPAIR PARTS GDH8 80% Two-Stage Hybrid Dedicated Downflow Gas Furnace GDH80453AXAA GDH80453AXAB GDH80453AXAC GDH80703AXAA GDH80703AXAB GDH80703AXAC GDH80904BXAA GDH80904BXAB GDH80904BXAC GDH155CXAA GDH155CXAB

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

Three-Way Mixing Valve. with or without presetting, for heating and cooling systems

Three-Way Mixing Valve. with or without presetting, for heating and cooling systems with or without presetting, for heating and cooling systems escription HEIMEIER three-way, with or without presetting, for mixing volume flows in heating and cooling systems, made of gunmetal, with protection

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

CV3000 Series. Characterized Insert Control Valves

CV3000 Series. Characterized Insert Control Valves CV3000 Series Characterized Insert Control Valves The CV3000 Series is a v-type control valve for precise control allowing high pressure drop capability with straight-through flow and bubble-tight shut

More information

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features T E C H N I C A L I N F O R M A T I O N M A N U A L F O R T H E A 1 0 V 0 V A R I A B L E D I S P L A C E M E N T P U M P S A10V0 PUMP Features High Efficiency through load sensing (= fuel savings) Maximum

More information

Cooling Water Flow Regulator

Cooling Water Flow Regulator Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data

More information

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series PiB Series PiB (Pump-in-a-Box) & 9 Series FILE NO: - DATE: July SUPERSEDES: - DATE: January 09 PiB Series Guaranteed In Stock At The Right Price! The PiB series builds on the high quality and unsurpassed

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

579(XX).(X)(X)(X)(X) Modularized Roof Top Air Conditioner

579(XX).(X)(X)(X)(X) Modularized Roof Top Air Conditioner When ordering parts, always state: MODEL NO. - PRODUT NO. - QUANTITY - PART NUMBER - DESRIPTION For Electric Details also state: VOLTAGE - WATTAGE USA SERVIE OFFIE Dometic orporation 0 Industrial Parkway

More information

REPAIR PARTS. *CVC95 C'Flow Variable Speed Furnace ACVC950714CXBA ACVC950915DXBA GCVC950714CXBA GCVC950915DXBA

REPAIR PARTS. *CVC95 C'Flow Variable Speed Furnace ACVC950714CXBA ACVC950915DXBA GCVC950714CXBA GCVC950915DXBA *CVC95 C'Flow Variable Speed Furnace ACVC950714CXBA ACVC950915DXBA GCVC950714CXBA GCVC950915DXBA REPAIR PARTS This manual is to be used by qualified technicians only. 2012 Goodman Manufacturing Company,

More information

REPAIR PARTS. *CVC9 90% C'Flow 2-Stage Variable Speed Furnace

REPAIR PARTS. *CVC9 90% C'Flow 2-Stage Variable Speed Furnace REPAIR PARTS *CVC9 90% C'Flow 2-Stage Variable Speed Furnace ACVC90704CXAA ACVC90704CXAB ACVC90905DXAA ACVC90905DXAB ACVC950714CXAA ACVC950915DXAA GCVC90704CXAA GCVC90704CXAB GCVC90905DXAA GCVC90905DXAB

More information

REPAIR PARTS. GMEC 96% EEM Up Flow Furnace. This manual is to be used by qualified technicians only.

REPAIR PARTS. GMEC 96% EEM Up Flow Furnace. This manual is to be used by qualified technicians only. REPAIR PARTS GMEC 96% EEM Up Flow Furnace GMEC960302BNAA GMEC960402BNAA GMEC960603BNAA GMEC960803BNAA GMEC9004CNAA GMEC9205DNAA www.amana-hac.com This manual is to be used by qualified technicians only.

More information

EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,

More information

Goodman Manufacturing Company, L.P San Felipe, Suite 500 Houston, TX 77056

Goodman Manufacturing Company, L.P San Felipe, Suite 500 Houston, TX 77056 REPAIR PARTS *CVM 96% Modulating Furnace ACVM960604CXAA ACVM960604CXBA ACVM960805DXAA ACVM960805DXBA ACVM961005DXAA GCVM960604CXAA GCVM960604CXBA GCVM960805DXAA GCVM960805DXBA GCVM961005DXAA GCVM961005DXBA

More information

Two-Stage, Variable-Speed Gas Furnace

Two-Stage, Variable-Speed Gas Furnace 80% AFUE GMV8 Two-Stage, Variable-Speed Gas Furnace Heating Input: 60,000 00,000 BTU/h Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve operates on two-stage

More information

REPAIR PARTS. GDS8 80% Furnace GDS80453AXCA GDS80453AXCB GDS80703AXCA GDS80703AXCB GDS80904BXCA GDS80904BXCB GDS81155CXCA GDS81155CXCB

REPAIR PARTS. GDS8 80% Furnace GDS80453AXCA GDS80453AXCB GDS80703AXCA GDS80703AXCB GDS80904BXCA GDS80904BXCB GDS81155CXCA GDS81155CXCB REPAIR PARTS GDS8 80% Furnace GDS80453AXCA GDS80453AXCB GDS80703AXCA GDS80703AXCB GDS80904BXCA GDS80904BXCB GDS855CXCA GDS855CXCB This manual is to be used by qualified technicians only. This manual replaces

More information

REPAIR PARTS. GUP, GUPI, and GUPX "B" SERIES

REPAIR PARTS. GUP, GUPI, and GUPX B SERIES REPAIR PARTS GUP, GUPI, and GUPX "B" SERIES GUPI050-3 GUPI075-3 GUPI075-4 GUPI100-4 GUPI100-5 GUPI120-5 GUPS050-2 GUPS075-3 GUPS100-3 GUPS100-4 GUPS120-4 GUPS120-5 GUPS140-5 GUPX050-3B GUPX075-4B GUPX100-5B

More information

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact

More information

REPAIR PARTS. *MVM96 Variable Speed Furnace

REPAIR PARTS. *MVM96 Variable Speed Furnace *MVM96 Variable Speed Furnace AMVM960603BXAA AMVM960603BXBA AMVM960805CXAA AMVM960805CXBA AMVM961005DXAA AMVM961005DXBA AMVM9655DXAA AMVM9655DXBA GMVM960603BXAA GMVM960603BXBA GMVM960805CXAA GMVM960805CXBA

More information

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details) Staco Energy Products Co. has been a leading manufacturer of variable transformers for over 60 years, building standard as well as custom-designed products for industrial, commercial and military applications.

More information

REPAIR PARTS. *MVC95 Variable Speed Furnace

REPAIR PARTS. *MVC95 Variable Speed Furnace *MVC95 Variable Speed Furnace AMVC950453BXBA AMVC950704CXBA AMVC950905CXBA AMVC950905DXBA AMVC9155DXBA GMVC950453BXBA GMVC950704CXBA GMVC950905CXBA GMVC950905DXBA GMVC9155DXBA REPAIR PARTS This manual

More information

P303 Pressure Regulator

P303 Pressure Regulator P0 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges Integral Monitoring The BelGAS P0 and P0H gas pressure reducing regulators are available with a true monitor regulator,

More information

INFRARED THERMOMETER Model : TM-959

INFRARED THERMOMETER Model : TM-959 LED target light, Emissivity adjustment INFRARED THERMOMETER Model : TM-959 Your purchase of this I N F R A R E D THERMOMETER marks a step forward for you into the field of precision measurement. Although

More information

GMVC 80% Variable Speed Communicating Furnace

GMVC 80% Variable Speed Communicating Furnace REPAIR PARTS GMVC 80% Variable Speed Communicating Furnace GMVC80604BNAA GMVC80604BNBA GMVC80604BNBB GMVC80604BNBC GMVC80604BXAA GMVC80604BXBA GMVC80604BXBB GMVC80604BXBC GMVC80805CNAA GMVC80805CNBA GMVC80805CNBB

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook Reference Manual 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com Reference Manual 405 and 1595 405 Compact Orifice Series and 1595 Conditioning

More information

THIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB.

THIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB. -. September, 9 II DIMS gas-fired, power vented and separated combustion unit heaters for models HD/HDB, HDS/HD, PS/BS, P I. Fuel supply shall be shut-off and the electrical power disconnected before proceeding

More information

MOTORIZED 3-WAY VALVE APPLICATION INSTRUCTIONS FOR LOW TEMPERATURE PROTECTION KIT MODELS PB AND CF/CH

MOTORIZED 3-WAY VALVE APPLICATION INSTRUCTIONS FOR LOW TEMPERATURE PROTECTION KIT MODELS PB AND CF/CH MOTORIZED -WY VLVE PPLICTION INSTRUCTIONS FOR LOW TEMPERTURE PROTECTION KIT 10017190 MODELS PB 50-001 ND CF/CH 0-07 WRNING Electrical Shock Hazard-- For your safety, turn OFF electrical power supply before

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book NOTICE Read

More information

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD Welcome Controller LCCONTROL20/D10 WE RE HERE TO HELP: 1 (844) LIGHTCLOUD 1 (844) 544-4825 support@lightcloud.com Contents Lightcloud Controller NPT Nut O-ring Instruction Manual Wire Nuts x 4 x 2 Specifications

More information

MICRO-AIR SERIES. miniature direct solenoid actuated valves

MICRO-AIR SERIES. miniature direct solenoid actuated valves R-R SERES miniature direct solenoid actuated valves RR i c r o i r d i r e c t s o l e n o i d a c t u a t e d m i n i a t u r e v a l v e s T E D T................................................... 3

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

Variable Speed 20 Single and Multi-spindle, Belt Drive Industrial Drill Presses www.clausing-industrial.com Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses Two Speed Variable Speeds 150-2000rpm Variable Speeds 200-1300rpm Variable Speeds 300-2000rpm

More information

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design rueninghaus Hydromatik Series 6, for open and closed circuits xial tapered piston, bent axis design Size 28...20 Nom. pressure up to 400 bar Peak pressure up to 40 bar RE 9606/0.97 RE 9606/0.97 replaces

More information

Y1SA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Y1SA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TEHNIAL SPEIFIATIONS Y1SA Series EarthDirEX Geothermal Direct Geoexchange Heat Pump ooling capacity,000 to 0,000 Heating capacity 1,000 to,000 EER 19.0 to.0 and OP.8 to.0 The Y1SA Geothermal heat pump,

More information

O Plus Dry Bushing 69 kv system, 350 kv BIL, 3000 A. Table of contents

O Plus Dry Bushing 69 kv system, 350 kv BIL, 3000 A. Table of contents Type test report O Plus Dry Bushing 69 kv system, 0 kv BIL, 000 A Table of contents Abstract... 2 2 Certification... 2 Introduction.... Description and ratings....2 Overview of tests.... Applicable standards....4

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 and 1595 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test

More information

AIR COOLED CONDENSING UNIT

AIR COOLED CONDENSING UNIT EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT Evolution Series BA-503-3 AUS Evolution Air Cooled Condensing Unit Series Content Page Explanation

More information

PRO-CLEAN STRATIFIED TANK

PRO-CLEAN STRATIFIED TANK PO-CLEAN STATIFIED TANK PODUCT DESCIPTION Pro-Clean stratified tank with spherical exchanger connection High-quality, multifunctional stratified tank made of steel (S J) for hot-water operation and domestic

More information

MET ONE RAIN GAGE MODELS 380, 385, 380M, 385M

MET ONE RAIN GAGE MODELS 380, 385, 380M, 385M MODELS 380, 385, 380M, 385M REVISION: 2/96 COPYRIGHT (c) 1993-1996 CAMPBELL SCIENTIFIC, INC. WARRANTY AND ASSISTANCE The MET ONE RAIN GAGE--MODELS 380, 385, 380M, 385M is warranted by CAMPBELL SCIENTIFIC,

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012 Replacement Parts List No. 055231000 Revision C 04/2012 Singer Incremental Comfort Systems K, EK 07-15 Vintage F Last Manufactured: 1976 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Questions with Illustrations as of August 15, 2008

Questions with Illustrations as of August 15, 2008 Questions with Illustrations as of August 15, 2008 ABS 210145 VER 1 Illustration: GS-0158 (Handbook of Instrumentation & Control, Kallen) The ball float shown in the illustration is 9 inches in diameter

More information

ISEmax CAS40D. Technical Information

ISEmax CAS40D. Technical Information Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor

More information

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014 Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5

More information

Cipriani Harrison Valves Corp.

Cipriani Harrison Valves Corp. Butterfly Valve pplication Stainless steel hygienic butterfly valves are used in process piping systems for isolation and control. Butterfly valves operate either manually or automatically. Working Principle

More information

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05 Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point

More information

AMVC 80% Variable Speed Communicating Furnace

AMVC 80% Variable Speed Communicating Furnace REPAIR PARTS AMVC 80% Variable Speed Communicating Furnace AMVC80604BNAA AMVC80604BNBA AMVC80604BNBB AMVC80604BNBC AMVC80604BXAA AMVC80604BXBA AMVC80604BXBB AMVC80604BXBC AMVC80805CNAA AMVC80805CNBA AMVC80805CNBB

More information

Automatic and Manual Safety Pilot Kits

Automatic and Manual Safety Pilot Kits Automatic and Manual Safety Pilot Kits Technical Control Systems Information For Peterson Vented Gas Logs RH Peterson Co. 14724 Proctor Ave * City of Industry * CA 91746 * 1(800) 332 3973 Website: www.rhpeterson.com

More information

5. DRIVE 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 6. ROW UNIT 7. OPTIONAL EQUIPMENT

5. DRIVE 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 6. ROW UNIT 7. OPTIONAL EQUIPMENT TABLE OF CONTENTS 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 5. DRIVE 6. ROW UNIT 7. OPTIONAL EQUIPMENT DRIVE Standard Turbofan 540, 450 & 1000 RPM with PTO Drive Your Monosem planter will be equipped

More information

7000 SERIES THUMBWHEEL SWITCHES

7000 SERIES THUMBWHEEL SWITCHES 7000 SERIES THUMBWHEEL SWITCHES The combines heavy-duty construction and a compact package size. Designed to meet demanding military performance specifications, the switch features a unique one-piece housing

More information

REPAIR PARTS. A/GPG13 Package Gas Units

REPAIR PARTS. A/GPG13 Package Gas Units REPAIR PARTS A/GPG13 Package Gas Units APG1324045MBA APG1324070MBA APG1330045MBA APG1330070MBA APG1336045MBA APG1336070MBA APG1336090MBA APG1342070MBA APG1342090MBA APG1348070MBA APG1348090MBA APG13485MBA

More information

LEVEL CONTROLS. Selection Guide. Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes

LEVEL CONTROLS. Selection Guide. Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes LEVEL CONTROLS Selection Guide Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes Capacitance Probe Calculations The following data is compiled to assist

More information

Device Specifications

Device Specifications Manual Device Specifications PART NUMBER LCGATEWAY ELECTRICAL The Lightcloud Gateway is designed to be hard-wired to AC power by a qualified electrician. INPUT 120-277 VAC, 50/60 Hz 60-45mA BATTERY Li-ion

More information

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel. Solenoid Valve Waterhammer-Free, 0- PSI /-Way; NPT - NPT; 0- PSI Advantages/Benefits Type 63 Waterhammer-free Low noise Zero differential pressure ompact design with high flow rates Low maintenance oil

More information

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard 92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1

More information

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard 92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1

More information

TERM 1185 ONLINE APPRENTICESHIP CLASS NUMBERS

TERM 1185 ONLINE APPRENTICESHIP CLASS NUMBERS Term Subject Area Catalog # Description Class Nbr Fee 1185 MPOA 1800 Basic Welding 1159 0.00 1185 ASTA 1804 Starting & Charging Systems 1007 0.00 1185 ASTA 1805 Ignition Systems 1008 0.00 1185 ASTA 1817

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information