Meiko USA 1349 Heil Quaker Blvd. Lavergne, TN
|
|
- Candace Melanie Cross
- 5 years ago
- Views:
Transcription
1 0 Meiko USA Heil Quaker Blvd. Lavergne, TN Model Number : Voltage : Phase : FV0. / DV0. 0VAC 0Hz Phase FOR USE WITH THE FOLLOWING OPTIONS: Internal Chemical Dosing Pumps Drain Water Tempering Kit Power Cord Kit External Vent Fan Control Dual Tank Fill System Released For Production : Editor : LAST DRAWER 0/0/00 0/0/00 /0/00 FV0. / DV0. USA 0V PH+G 0Hz COVER PAGE FV0. / DV0. Page
2 / ALLOCATION TABLE LEVEL / ASSIGNMENT CONNECTION - - S: S: DOOR CLOSED BOOSTER LEVEL SWITCH XA XA / / S: FLOOR LEAKAGE XA XA XA XA XA / / / / - XA / FSK: FSR: RINSE AID LEVEL (OPT.) DETERGENT LEVEL (OPT.) XA XA / / LD: CHEMICAL LEAK DETECTION XA XA XA / / / B: B: BOOSTER TEMPERATURE TANK TEMPERATURE XA XA / / - B: TANK LEVEL XA0 // K: M: M: BOOSTER PUMP CONTACTOR GEARED MOTOR (WASH ARM MOTION) DRAIN PUMP XA XA XA M/KP: M/RP: K: RINSE AID DOSING DETERGENT DOSING POWER CUTTING CONTACTOR XA XA XA Y: FILLING VALVE Y./Y.: SOFT START VALVE K./K.: BOOSTER HEATING CONTACTOR XA XA XA K./K.: TANK HEATING CONTACTOR K./K.: WASH PUMP CONTACTOR XA XA XA 0/0/00 0/0/00 LAST DRAWER /0/00 FV0. / DV0. USA 0V PH+G 0Hz ALLOCATION TABLE FV0. / DV0. Page
3 XH DISPLAY MIKE-LED - 0 A XB XB XB XB CPU BOARD MIKE-CPU - 0 A MIKE EEPROM MIKE - EPROM XB XB XB INTERNAL BUS +V DC POWER PACK MIKE-NET - 0 G XC XC controlled POWER SUPPLY 0-0V / -Hz X L X L X F AT 0 +V DC TOUCH PANEL A INTERNAL BUS POWER SUPPLY 0-0V / -Hz X L X L X XC POWER PACK MIKE-NET - 0 G F AT XC 0 +V DC +V DC +V DC R 0 Ohm,0 Watt +V DC +V DC XA XA XA 0 XA XA 0 I/O-UNIT MIKE-E/A - A XA XA XA S00 XA0 ON XA X 0/0/00 0/0/00 LAST DRAWER /0/00 FV0. / DV0. USA 0V PH+G 0Hz ELECTRONIC CONTROL FV0. / DV0. Page
4 0 MIKE-E/A A/XA CONNECTION: B - WH AMP Duoplug OUT - GN +VDC - BN CONNECTION M K/ K/ C K. B: B: B: S: S: S: LD: CELLS FSK: MIKE-E/A BOOSTER TEMPERATURE SENSOR TANK TEMPERATURE SENSOR TANK LEVEL DOOR SAFETY SWITCH BOOSTER LEVEL SWITCH LEAK WATER - PAN LEAKAGE DOSING LEVEL RINSE-AID FSR: LEVEL DETERGENT MIKE-E/A A/XA K: K: K./K.: WASH PUMP CONTACTOR K: K: K: K: K: Y: COMPONENTS V DC Y./Y.: SOFT STARTER MIKE-E/A A/XA BOOSTER CONTACTOR TANK HEAT. CONTACTOR POWER CUTTING CONTACTOR BOOST PUMP CONTACTOR DRAIN PUMP CONTACTOR RELAY FILLING VALVE RELAY SOFT STARTER VALVE FILLING VALVE MIKE-E/A A/XA COMPONENTS V DC M: M: E./E.: BOOSTER HEATING E./E.: TANK HEATING M: M: M: M: RINSE AID DOSING (KP) DETERGENT DOSING PUMP (RP) COMPONENTS 0V AC WASH PUMP (WP) BOOST-PUMP (DSP) DRAIN PUMP (LP) GEARED MOTOR MIKE-E/A A/XA0 x,0 KW x,0 KW x, KW 0, KW 0,0 KW 0,0 KW 0 0 K A A K A A K A A K A A A A K. A A K Y K X Y. RC. 00 Ohm nf Y. RC. 00 Ohm nf./ FSK/./ FSK/./ FSR/./ FSR/ LD XB B XB B S S B +VDC - BN OUT - gn P S X XKP//.0 XRP//. XKP//.0 XRP//. X X X X X DC X X L X L X L MIKE-NET G/XC X 0 +V DC MIKE-NET G/XC DC MIKE-NET G/XC 0 +V DC MIKE-NET G/XC MIKE-NET G/XC MIKE-NET G/XC F 0A X L L./ L./ L T 0VA F0 0,A T 0 U 0V U 0V U F0 0,A T MIKE-E/A A/XA F00 A T A/XA 0-0V PH+ 0Hz Q A Q 0A Q..A Q..A Q.A Q 0.A X K E. E. K E. E. K. M. U V W W U U V V W K. M. U V W W U U V V W XM K U M U V V W W M//. M//. K XM M//. M//. U V W M W U V U V W /. K C,µF M M//../ M/ K A A K A A M//../ M/ K A A 0/0/00 0/0/00 LAST DRAWER /0/00 FV0. / DV0. USA 0V PH+G 0Hz ELECTRONIC CONTROL FV0. / DV0. Page
5 0 INTERNAL DOSING PUMPS - VDC EXTERNAL DOSING PUMPS - CHEMICAL AGENT LEVEL SENSOR (OPTIONAL) CHEMICAL AGENT LEVEL SENSOR (OPTIONAL) MIKE- E/A A./XA MIKE-E/A A./XA MIKE- E/A A./XA MIKE-E/A A./XA MIKE-E/A A./XA MIKE- E/A A./XA XC/ XC/ XC/0 XC/ XKP XRP DC V DC DC V DC XKP XRP GROUND XKP XRP FSK FSR FSK FSR XKP XRP FSK FSR FSK FSR XD XD XD XD XD L XD L XD XD XD XD XD FSK FSR M M RINSE AID DOSING PUMP VDC M M DETERGENT DOSING PUMP VDC SIGNAL FOR RINSE AID PUMP 00 VAC max A max SIGNAL FOR DETERGENT PUMP 00 VAC max A max L /. 0V L /. 0V SUPPLIED BY MACHINE Umax=00V AC / Imax=A 0æS 0æS 0/0/00 0/0/00 LAST DRAWER /0/00 FV0. / DV0. USA 0V PH+G 0Hz CHEMICAL DOSING CONNECTIONS FV0. / DV0. Page
6 0 EXTERNAL VENT FAN CONTROL WASH TANK FILL XC / G # EVTR K. / A EVFC A A EVTR A A FOR EXHAUST FAN - IN* B TO EXHAUST FAN - OUT* K / A K / K / A K A T A F R A A R T Y K MIKE - NET G/XC +V DC 0 MIKE - NET G/XC GROUND DC L L L T T T EVFC * AWG 0A MAXIMUM EVTR TIMER SETTINGS - DIAL STYLE F: WASH TANK FLOAT K: ANTI CHATTER RELAY R: WASH TANK FILL RELAY T: OFF DELAY TIMER WASH TANK FILL (SET TO 0 SECONDS) Y: WASH TANK FILLING VALVE EVTR TIMER SETTINGS - DIP SWITCH STYLE SET TO 0 % SET DIP SWITCHES TO: - DOWN - UP - UP - DOWN - DOWN - UP 0/0/00 0/0/00 LAST DRAWER 0//00 FV0. / DV0. USA 0V PH+G 0Hz MACHINE OPTIONS FV0. / DV0. Page
Meiko USA 1349 Heil Quaker Blvd. Lavergne, TN
0 Meiko USA Heil Quaker Blvd. Lavergne, TN 0 00--0 Model Number : Voltage : Phase : FV0. / DV0. 0V-0VAC 0Hz Phase FOR USE WITH THE FOLLOWING OPTIONS: Internal Chemical Dosing Pumps Drain Water Tempering
More informationSpare parts list UC-S
Spare parts list UC-S Contents Water inlet and tank heating Water softener Water drain, Mediamat Cyclo Circulating pump Wash + rinse; bottom Wash + rinse; top Boiler Dosage Panelling Cover plate, electrical
More informationSpare parts list UC-M, UC-L, UC-XL
Spare parts list Contents Water inlet and tank heating Water softener Water drain, Mediamat Cyclo Circulating pump Wash + rinse; bottom Wash + rinse; top Boiler Dosage Panelling Cover plate, electrical
More informationSpare parts list GS 660
Spare parts list GS 0 Contents Water inlet up to mach. no.: 0 Page Water inlet from mach. no. 0 Page Tank and tank heating Page Water drainage, Mediamat Cyclo Page Wash pump Page Bottom washing system
More informationCOLGED. Toptech
COLGED SPARE PARTS CATALOGUE ERSATZTEILKATALOG CATALOGUE PIECES DETACHEES CATALOGO PARTI RICAMBIO CATALOGO DE PIEZAS DE RECAMBIO CATALOGO PECAS, DE REPOSICAO Toptech -. -09-0 R L 9 0 0 0 0 9 MOD T0 MOD
More informationREPAIR PARTS. GPH13 "H" Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB
REPAIR PARTS GPH13 "H" Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB This manual is to be used by qualified technicians only. 2010 Goodman Manufacturing
More informationREPAIR PARTS. CPLT 13 SEER Series Condensing Units CPLT24-1 CPLT24-1A CPLT30-1 CPLT30-1A CPLT36-1 CPLT42-1 CPLT48-1 CPLT60-1
REPAIR PARTS CPLT 13 SEER Series Condensing Units OPTIONAL COMPRESSOR WARRANTY CPLT24-1 CPLT24-1A CPLT30-1 CPLT30-1A CPLT36-1 CPLT42-1 CPLT48-1 CPLT60-1 This manual is to be used by qualified technicians
More informationEXEMPLAR NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 ( ) (X-Paper) 09:00 12:00
NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 2008 (12041002) (X-Paper) 09:00 12:00 EXEMPLAR This question paper consists of 7 pages. EXEMPLAR -2- NC(V) TIME: 3 HOURS
More informationMcQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017
Replacement s List No. 055206700 Revision B 02/2017 McQuay Water Source Heat Pump VF, VG, VP 240-390 Vintage E, F, G Last Manufactured: 1992 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay Climate Control Singer
Replacement Parts List No. 055204800 Revision B 01/2017 McQuay Climate Control Singer Vertical Water Source Heat Pump FC, FG, FW 240, 330, 400, 500 Vintages C, D Last Manufactured: 1986 To find your Daikin
More information48 Dual Fuel Range with Grill
DF GR, DF GR LP Image of the HR 1956 DF GD 48 Range with Griddle 8mieleusa.com Model: DF GR / DF GR LP SPECIFICATIONS DF GR / DF GR LP Features: M Touch controls and backlit precision knobs ComfortLift
More information6.0 EC-SERIES CUBERS EC200-EC300-EC400-EC500-EC606 AIR, WATER AND REMOTE
6.0 EC-SERIES CUBERS EC200-EC300-EC400-EC500-EC606 AIR, WATER AND REMOTE Item EC EC EC EC EC EC Code Part Description Part Number GRP 200 300 400 406 500 606 AIR COOLED 5 Air Condenser 9141048-01 AC X
More informationREPAIR PARTS. GPH H-SERIES Package Heat Pumps
REPAIR PARTS GPH H-SERIES Package Heat Pumps GPH1324HAB GPH1324HAC GPH1324HAD GPH1324HA GPH1330HAB GPH1330HAC GPH1330HAD GPH1330HA GPH1336HAB GPH1336HAC GPH1336HAD GPH1336HAE GPH1336HA GPH1342HAB GPH1342HAC
More informationPanel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)
Staco Energy Products Co. has been a leading manufacturer of variable transformers for over 60 years, building standard as well as custom-designed products for industrial, commercial and military applications.
More informationDIN Timers TD. Options and ordering codes. Specification
DIN imers D 17.5mm or 22.5mm DIN rail mounting Electronic imers Wide coil operation, 24V to 320V AC/DC Multi ime range / Multi function ON-Delay, OFF-Delay, Asymetrical, Star/Delta versions Perfect to
More information15.0 UNDERCOUNTER CUBERS EUC150B2 EUC200B3-EUC200-UC20B-UC20 AIR AND WATER COOLED
15.0 UNDERCOUNTER CUBERS EUC150B2 EUC200B3-EUC200-UC20B-UC20 AIR AND WATER COOLED Item EUC EUC EUC EUC UC UC Code Part Description Part Number GRP 150 200B3 200 206 20B 20 Shaded Item Code indicates updated
More informationParts Manual R410A Models
Parts Manual R410A Models PTAC - PD Series (Electronic Controls) Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps PTAC PARTS E (1-2010) Table of Contents Unit Identification... 2 PTAC System
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationMcQuay Climate Control. Water Source Heat Pump Horizontal. CC, CG, CW Vintage C, D. Last Manufactured: 1984
Replacement Parts List No. 055204000 Revision C 01/2017 McQuay Climate Control Water Source Heat Pump Horizontal CC, CG, CW 260-330 Vintage C, D Last Manufactured: 1984 To find your Daikin Applied parts
More information48 Dual Fuel Range with Grill
DF GR, DF GR LP Image of the HR 1956 DF GD 48 Range with Griddle 8mieleusa.com DF GR / DF GR LP Features: M Touch controls and backlit precision knobs ComfortLift panel M Pro dual stacked burner system
More informationPARTS LIST GAS BOILERS MODELS: CG320 (E) CG325 (E) CG330 (E)
PARTS LIST GAS BOILERS MODELS: CG320 (E) CG325 (E) CG330 (E) CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE: (416) 746-2358, FAX: (416) 746-8324
More informationMcQuay Climate Control Singer. Incremental. NE, NH, NR Vintages C, D. TYA, TAA Vintages A, B. Last Manufactured: 1999
Replacement Parts List No. 055233900 Revision D 08/2017 McQuay Climate Control Singer Incremental NE, NH, NR 07-18 Vintages C, D TYA, TAA 007-015 Vintages A, B Last Manufactured: 1999 To find your Daikin
More informationREPAIR PARTS CKF* 50 Hz Remote Condensing Units
REPAIR PARTS CKF* 50 Hz Remote Condensing Units CKF24-2M CKF24-2N CKF36-2M CKF36-2N CKF36-5M CKF36-5N CKF48-5M CKF48-5N CKF60-5M CKF60-5N CKF70-5M CKF70-5N Important Information Index Functional s List
More information08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics
0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7
More informationME 4232: FLUID POWER CONTROLS LAB. Class #5 Valve Modeling
ME 4232: FLUID POWER CONTROLS LAB Class #5 Valve Modeling Notes No Office Hours Today Upcoming Labs: Lab 9: Flow Divider Lab 10: Sequencing Circuits 2 Agenda Wrap-up: Leakage Calculations Fluid Compressibility
More informationREPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA
REPAIR PARTS GPH14 H-SERIES R-0A Package Heat Pumps GPH1424HAA GPH1430HAA GPH1436HAA GPH1442HAA GPH1448HAA GPH1460HAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing
More informationRepair Parts List DUEL FUEL RANGE MODEL NUMBER SVD48600BC. When requesting service or ordering parts, always provide the following information:
Repair Parts List DUEL FUEL RANGE MODEL NUMBER SVD48600BC When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description
More informationREPAIR PARTS. GPH13 "M" Series Horizontal Package Heat Pumps GPH1324M41AA GPH1330M41AA GPH1336M41AA GPH1342M41AA GPH1348M41AA GPH1360M41AA
REPAIR PARTS GPH13 "M" Series Horizontal Package Heat Pumps GPH1324MAA GPH1330MAA GPH1336MAA GPH1342MAA GPH1348MAA GPH1360MAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing
More informationREPAIR PARTS. GPH16 Horizontal Package Heat Pumps. This manual is to be used by qualified technicians only.
REPAIR PARTS GPH16 Horizontal Package Heat Pumps GPH1624H41AA GPH1630H41AA GPH1636H41AA GPH1642H41AA GPH1648H41AA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com
More informationCookers. Always fresh. Always delicious.
Cookers Always fresh. Always delicious. Gas Cookers WGC576DX3X (220V, 50/60Hz) Stainless Steel Double Oven 1 Large Center Burner Electronic Ignition with 3 Rack Positions in Lower Oven 1 Fixed Oven Rack
More informationREPAIR PARTS. GPH14 Multi-Position Residential Package Heat Pump. This manual is to be used by qualified technicians only.
REPAIR PARTS GPH14 Multi-Position Residential Package Heat Pump GPH1424MAA GPH1424MAB GPH1430MAA GPH1430MAB GPH1436MAA GPH1436MAB GPH1442MAA GPH1442MAB GPH1448MAA GPH1448MAB GPH1460MAA GPH1460MAB This
More informationTSC JR 2 Manual SERIES 4B, 5B & 6B
TSC JR 2 Manual SERIES 4B, 5B & 6B TSC JR 2 Two Valve Timed Sequence Controller Revised: April 17, 2002 Operation Manual Distributed By: DESCRIPTION The TSC JR 2 is a two valve timer designed to be reliable
More informationPARTS LIST WATER SOURCE HEAT PUMPS HLH/HLV
PARTS LIST WATER SOURCE HEAT PUMPS HLH/HLV 1900 Wellworth Ave. Jackson, MI 49203 www.heatcontroller.com 517-787-2100 HLH PARTS LIST 072 096 120 Part # Item Description 3 3 3 3 3 3 3 3 Compressors 68832733
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationOUTDOOR UNITS. Introduction YMF-C. Introduction. Refrigerant
Introduction Introduction Refrigerant R407C R Series Y series (Heat Pump) R series (Air-cooling) Y series ( Only) Y series (Heat Pump) R series (Air-cooling) Y series ( Only) OUTDOOR UNITS Model Name -YMF-C
More informationENGR-4300 Fall 2008 Test 3. Name SOLUTION. Section 1(MR 8:00) 2(TF 2:00) (circle one) Question I (20 points) Question II (15 points)
ENGR-4300 Fall 008 Test 3 Name SOLUTION Section (MR 8:00) (TF :00) (circle one) Question I (0 points) Question II (5 points) Question III (0 points) Question I (0 points) Question (5 points) Total (00
More informationMetallized Polypropylene film capacitor PCMP 371
MKP RADIAL POTTED CAPACITORS Pitch 22.5/27.5 mm QUICK REFERENCE DATA Capacitance range Capacitance tolerance Rated voltage (AC) Rated Frequency Climatic category Temperature range Reference specification
More informationtechnical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )
Installation Instructions: Wall-Mount Dewpoint Probe (809-2011) The HMW90 Wall-Mount Dewpoint Probe (P/N 809-2011) HMW90 measures dewpoint for indoor applications such as anti-sweat heater control and
More informationCEILING WALL type SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models
SPLIT TYPE ROO AIR CONDITIONER CEILING WALL type INVERTER odels Indoor unit AWHZLBC AWHZLBC Outdoor unit AOHZLBC AOHZLBC CONTENTS SPECIFICATIONS.................... OUTLINE AND DIENSIONS.......... REFRIGERANT
More informationCAUTION. All safety information must be followed as provided in this Technical Sheet and in Service Manual RS
peed Queen Domestic asher echnical nformation 0 V, 0 Hz Models 70 70 Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.
More informationREPAIR PARTS. DZ13SA Remote Heat Pumps (3-Phase) DZ13SA0363AA DZ13SA0483AA DZ13SA0484AA DZ13SA0603AA DZ13SA0604AA
DZ13SA Remote Heat Pumps (3-Phase) DZ13SA0363AA DZ13SA0483AA DZ13SA0484AA DZ13SA0603AA DZ13SA0604AA REPAIR PARTS This manual is to be used by qualified technicians only. 2013 Daikin Manufacturing Company,
More informationKF Series. -40 to to 100 VDC 0.47 to F
Low Impedance Features Used in communication equipments, switching power supply, industrial measuring instruments, etc. Load life 000~000 Hrs at Safety vent construction design. For detail specifications,
More informationThe Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:
The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering
More informationequator COMBINATION OVENS
equator COMBINATION OVENS EQUATOR the new generation of combination ovens Since 2007, with the ITW group at the head of 840 facilities in 57 countries Bonnet has benefitted from its research and development
More informationCommon Lightcloud Wiring Applications. Wiring Diagrams. Overview Controller Dimmer Gateway Integrator Sensor Touch. Lightcloud
Common Lightcloud Wiring Applications Wiring Diagrams Overview Dimmer Gateway Integrator Sensor Touch Lightcloud Wiring Diagrams The following diagrams are commonly used for Lightcloud installations. If
More informationSoftstarter range type PSD & PSDH
Softstarter range type SD & SDH Description Softstarters type S D and S DH ABB s solid state starter range is used when it is important to have a smooth start-up of various types of motor drives. Instead
More information36 Dual Fuel Range with Griddle
DF GD, DF GD LP miele.ca Model: DF GD / DF GD LP SPECIFICATIONS DF GD / DF GD LP Features: M Touch controls and backlit precision knobs ComfortLift panel M Pro dual stacked burner system with TrueSimmer
More informationHVAC Electrical Wiring Diagrams / Ohm s Law / Sequence of Operation RV
PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.
More informationGeneral characteristics, Products
The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload
More informationMiddlebridge Scimitar - Wiring Diagram Key
Middlebridge Scimitar - Wiring Diagram Key Produced by Phil Wormald 14/05/2001 e:mail: phil.wormald@ntlworld.com tel.: 0115 9137351 This wiring diagram key has been produced as accurately as possible The
More informationREPAIR PARTS. GPH14 "M" Series Residential Package Heat Pump. This manual is to be used by qualified technicians only.
REPAIR PARTS GPH14 "M" Series Residential Package Heat Pump GPH1424MAA GPH1430MAA GPH1436MAA GPH1442MAA GPH1448MAA GPH1460MAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com
More information100Z-1 100Z-1 51 HA 50. Cushion ring Cushion ring. Type. Standard type. Switch Set
0Z-1 0Z-1 51 Type Nominal pressure Maximum allowable pressure Proof test pressure Minimum operating pressure Working speed range Working temperature range (ambient/fluid temperature) Structure of cushioning
More information2002 Prentice Hall, Inc. Gene F. Franklin, J. David Powell, Abbas Emami-Naeini Feedback Control of Dynamic Systems, 4e
u Figure 2.1 Cruise-control model x Friction force bx m x u Figure 2.2 Free-body diagram for cruise control S P 278 Figure 2.3 Automobile suspension y m 2 k s b v car x m 1 k w Road surface r Inertial
More informationSpare parts list GS 502, GS 515
Spare parts list Contents Water inlet + tank heating Page Water inlet + Water softener Page Water drain, Mediamat Cyclo Page Wash pump Page Wash system, bottom Page Wash system, top up to machine no.:
More informationREPAIR PARTS. SSZ14 R-410A Remote Heat Pumps
REPAIR PARTS SSZ14 R-410A Remote Heat Pumps SSZ1401AA SSZ1401AB SSZ140241AA SSZ140241AB SSZ140241AC SSZ140241AD SSZ140241AE SSZ140301AA SSZ140301AB SSZ140301AC SSZ140361AA SSZ140361AB SSZ140361AC SSZ140361AD
More informationProperty of American Airlines
L L L PE INCOMING POWER 0V/PH/0HZ/00AMPS C CIRCIT REAKER REMOTE OVER CRRENT ISCONNECT REQI PER NEC AWG CIRCIT REAKER CONTACTOR CONTROL RELAY CRRENT TRANSCER MOTOR STARTER OVERLOA RELAY NIT - RIGE INTERCONNECTION
More informationRELAYS. Phone: Fax: Web:
RELAYS Phone: 00..0 - Fax:.. - Web: www.clrwtr.com - Email: info@clrwtr.com MRC -Pole, Standard -Pin Plug-In Relay Gap. mm S-B, S-S, S-L, S-PO A(+) Table Electrical Life, ops. x 0 C-G0 General purpose,
More informationREPAIR PARTS. GSH13 Remote Heat Pumps
REPAIR PARTS GSH13 Remote Heat Pumps GSH1301AC GSH1301BA GSH130191AC GSH130241AC GSH130241BA GSH1302AC GSH1302AE GSH130301AC GSH130301BA GSH1303AC GSH1303AE GSH130361AC GSH130361AD GSH130361BA GSH130361BB
More information7.3 State Space Averaging!
7.3 State Space Averaging! A formal method for deriving the small-signal ac equations of a switching converter! Equivalent to the modeling method of the previous sections! Uses the state-space matrix description
More informationREPAIR PARTS. GSZ 13 SEER R410A Remote Heat Pumps
REPAIR PARTS GSZ 13 SEER R0A Remote Heat Pumps GSZ130181AB GSZ1302AB GSZ1302AC GSZ1302BA GSZ130301AB GSZ130301AC GSZ1303AB GSZ1303BA GSZ130363AA GSZ1304AB GSZ130481AB GSZ130483AA GSZ130484AA GSZ130601AB
More informationElectronics 101. John Sweeny Saturday September 28 th, 2013 OFF
Electronics 101 NANT New York John Sweeny Saturday September 28 th, 2013 OFF Is this your understanding of a Dialysis Machine? 2 Electricity is intimidating because Human aren t equipped to detect it until
More informationOC330C. Wiring Diagram. Recommended PKH- P35 / P50 GALH PKA- RP35 / RP50. Remarks (Drawing No.) No. Parts No. Parts Name Specifications
G G " # $ % & " ' ( ) $ * " # $ % & " ( + ) $ * " # C % " ' ( ) $ * C " # C % " ( + ) $ * C D ; E @ F @ 9 = H I J ; @ = : @ A > B ; : K 9 L 9 M N O D K P D N O Q P D R S > T ; U V > = : W X Y J > E ; Z
More information400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL
400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. July 2013 REV. 015 2013 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix AP Harmonic
More informationSERVOSTAR S- and CD-Series Regeneration Requirements
www.danaherotion.com SEROSTAR S- and CD-Series Regeneration Requirements One of the key (and often overlooked) considerations for servo system sizing is regeneration requirements. An undersized regeneration
More informationA New Coaxial Flow Calorimeter for Accurate RF Power Measurements up to 100 Watts and 1 GHz Andrew S. Brush Jefferson D. Lexa
Slide 1 A New Coaxial Flow Calorimeter for Accurate RF Power Measurements up to 100 Watts and 1 GHz Andrew S. Brush Jefferson D. Lexa Motivation Slide 2 Decrease uncertainty of working standards at 100
More informationWALL MOUNTED CASSETTE type
HIGH POWER MULTI AIR CONDITIONER WALL MOUNTED CASSETTE type Models Indoor unit RSM-FA RCM-FA RSM-FA RCM-FA Outdoor unit ROM-FA ROM-FA ROM-FA CONTENTS SPECIFICATIONS..................... OUTLINE AND DIMENSIONS...........
More informationSECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM
SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM Unit Objectives Describe the structure of an atom. Identify atoms with a positive charge and atoms with a negative charge. Explain
More informationCROSS FLOW COOLING TOWER
CROSS FLOW COOLING TOWER LUCKY GREEN THAI INDUSTRIES CO LTD Material Specification Model LGX 80 00 0 00 0 300 30 400 00 600 700 800 000 Motor Totally enclosed Totally enclosed fan cooled Driving System
More informationNME1854 & FME2404 SERVICE PARTS
NME & FME0 SEICE PATS This parts list contains the service parts and wiring diagrams for this model. Water cooled condensers changed between the A and B series. Check the model number in question to be
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models CONTENTS
SPLIT TYPE AIR CONDITIONER CASSETTE type (0Hz) Models Indoor unit RC-FA RC-UA Outdoor unit RO-FA RO-UA CONTENTS SPECIFICATIONS............................. DIMENSIONS................................ REFRIGERANT
More informationSafety Barriers Series 9001, 9002 Standard Applications
Standard s Analog input with transmitter Smart 9001/51-80-091-141 09949E0 Load of transmitter U N = + 0 V... 35 V I N = 3.6 ma... ma R L ( 350 O U min (I N= 0 ma) U N - 9.5 V 14 V U N ( 3.5 V > 3.5 V Maximum
More informationPARTS MANUAL Gas Furnace F9MAC, G9MAC
Gas Furnace F9MAC, G9MAC Safety Labeling and Signal Words DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal
More informationBV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton
BV SERIES VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton MAGIC AIRE BV SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.
More informationTECHNICAL MANUAL 820 LX / 910 LX / 1300 LX
TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX LANCER reserves the right to modify, constantly its documentation for its improvement. The values of adjustments indicated in the displays of this manual are
More informationREPAIR PARTS. GPH14 "H" Residential Package Heat Pump
REPAIR PARTS GPH14 "H" Residential Package Heat Pump GPH1424H41AB GPH1424H41AC GPH1424H41BA GPH1424H41CA GPH1424H41DA GPH1424H41DB GPH1430H41AB GPH1430H41AC GPH1430H41BA GPH1430H41CA GPH1430H41DB GPH1436H41AB
More informationREPAIR PARTS. GPH14 H-Series Package Heat Pumps. This manual is to be used by qualified technicians only. This manual replaces RP-631C.
REPAIR PARTS GPH14 H-Series Package Heat Pumps GPH1424H41AB GPH1424H41AC GPH1424H41BA GPH1424H41CA GPH1424H41DA GPH1430H41AB GPH1430H41AC GPH1430H41BA GPH1430H41CA GPH1436H41AB GPH1436H41AC GPH1436H41BA
More informationSINAMICS G120X. Available in power ratings up to 700 hp (630 kw) Technical documentation 01 / 2019
SINAMICS G120X Available in power ratings up to 700 hp (630 kw) Technical documentation 01 / 2019 An infrastructure drive for pumps, fans and compressors Siemens introduces an exciting new addition to
More informationExercise 1: RC Time Constants
Exercise 1: RC EXERCISE OBJECTIVE When you have completed this exercise, you will be able to determine the time constant of an RC circuit by using calculated and measured values. You will verify your results
More information450W/650W/1000W Modular Power
50W/650W/000W Modular Power Output Configuration Guide MP - - SLOT SLOT SLOT SLOT SLOT5 SLOT6 SLOT7 50/650/K0(50W/650W/000W) Modular Power with PFC 50W/650W(5SLOT) 000W(7SLOT) Example: MPK0- A E # S SLOT
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER AUY25FUAR AOY25FNAKL AUY25UUAR AOY25UNAKL. Models Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit AUY5FUAR AOY5FNAKL AUY5UUAR AOY5UNAKL CONTENTS SPECIFICATIONS....................................... OUTLINE AND DIMENSIONS.............................
More informationR.46. X2 CLASS (IEC ) - MKP Series SELF-HEALING PROPERTIES 09/
Loose Taped X CLASS (IEC 60384-4) - MKP Series Typical applications: interference suppression and «across-the-line» applications. Suitable for use in situations where failure of the capacitor would not
More informationAmerican Zettler AZ742 RELAY Datasheet
American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching
More informationS Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems
INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS Time base: 60 Hz (3-wire system) Quartz (2-wire system) Power input: 85 135 VAC / 60 Hz 7 28 VAC / 60 Hz Current consumption:
More informationREPAIR PARTS. SSZ16 Remote Heat Pump Unit
REPAIR PARTS SSZ16 Remote Heat Pump Unit SSZ160241AA SSZ160241AB SSZ160241AC SSZ160241AD SSZ160241AE SSZ160241AF SSZ160241AG SSZ1603AA SSZ1603AB SSZ1603AC SSZ1603AD SSZ1603AE SSZ160481AA SSZ160481AB SSZ160481AC
More informationRemote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.
Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark.
More information1 of 23. Boardworks Ltd Electrical Power
1 of 23 Boardworks Ltd 2016 Electrical Power Electrical Power 2 of 23 Boardworks Ltd 2016 What is electrical power? 3 of 23 Boardworks Ltd 2016 Electrical power is the rate at which energy is transferred
More informationPetrochemical. Transformer Oil Gas Analysis - TOGA
Petrochemical Transformer Oil Gas Analysis - TOGA www.dps-instruments.com The DPS TOGA GC Systems are designed to analyze oil from electrical insulation materials that may have decomposed under thermal,
More informationClimateMaster s Tranquility 22. Raj Hiremath Director of Residential Marketing
ClimateMaster s Tranquility 22 Raj Hiremath Director of Residential Marketing 1 CLIMATEMASTER Industry leader since 1950 s First to introduce 2-stage 27 EER unit First to introduce Outdoor split system
More informationUNIT G485 Module Capacitors PRACTICE QUESTIONS (4)
UNIT G485 Module 2 5.2.1 Capacitors PRACTICE QUESTIONS (4) 1 A 2200 µf capacitor is charged to a p.d. of 9.0 V and then discharged through a 100 kω resistor. (a) Calculate : (i) The initial charge stored
More informationThe most complete line of... System Alarms Float Switches On-Site Accessories Control Panels
The most complete line of... System Alarms Float Switches On-Site Accessories Control Panels C A T A L O G Enviro-Flo Inc. P.O. Box 321161 151 Custom Drive Flowood, MS 39232 Office: 601-939-2966 Fax: 601-939-3526
More information30C Definite Purpose Contactor
0C Definite Purpose Contactor 0FLA FLA Pole Nomenclature 0C P J 00 Design number 0C; Series Number 0C, Definite purpose contactor Contact Rating: 0FLA FLA 0FLA FLA; FLA 0FLA FLA 0FLA 0FLA FLA Pole and
More informationCoulomb s constant k = 9x10 9 N m 2 /C 2
1 Part 2: Electric Potential 2.1: Potential (Voltage) & Potential Energy q 2 Potential Energy of Point Charges Symbol U mks units [Joules = J] q 1 r Two point charges share an electric potential energy
More information+ ( )= with initial condition
Department of Electrical Engineering PhD. Admission Test Full Marks: 90 Time 90 minutes Date: 02.2.204 NAME: Appl. No: Write your answer on the question paper ONLY. All questions carry equal marks. PART
More informationREPAIR PARTS. GPG14 "M" Series Residential Package Gas Units. This manual is to be used by qualified technicians only. This manual replaces RP-G3001.
REPAIR PARTS GPG14 "M" Series Residential Package Gas Units GPG1424040MAA GPG1424040MAB GPG1424060MAA GPG1424060MAB GPG1430040MAA GPG1430040MAB GPG1430060MAA GPG1430060MAB GPG1436040MAA GPG1436040MAB GPG1436060MAA
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit RC-36HB RO-36HC RC-45HB RO-45HB
SPLIT TYPE AIR CONDITIONER CASSETTE type (0Hz) Models Indoor unit Outdoor unit RC-6HB RO-6HC RC-HB RO-HB CONTENTS SPECIFICATIONS......................... OUTLINE AND DIMENSIONS............... CIRCUIT DIAGRAM.......................
More informationGS4000 DATASHEET JUNHO 2013
GS4000 DATASHEET JUNHO 2013 www.severntrentservices.com Biochem T70GS4000 Chlorine Dioxide Generator - 2g/day - 10g/h System Advantages Dosage Flexibility The generator produces a chlorine dioxide solution,
More informationMULTI-OUTPUT PROGRAMMABLE CONTROLLERS MODELS UMX-4 & UMX-8
February 1994 20/20 Interface Products MULTI-OUTPUT PROGRAMMABLE CONTROLLERS MODELS & DESCRIPTION The is a Multi-output Programmable Controller which expands the input or output capability of building
More informationAF SERIES AWEA MECHANTRONIC CO., LTD. High Performance Vertical Machining Center AGENT ISO 9001 ISO 14001
AWEA MECHANTRONIC CO., LTD. HEADQUARTERS 629, Suezhetou Section, Kwanpu Rd., Wenshan Li, Hsinpu, Hsinchu, Taiwan TEL : +886-3-88-191 FAX : +886-3-88-19 Website : www.awea.com CENTRAL TAIWAN SCIENCE PARK
More informationParts List with Exploded Views
Parts List with Exploded Views Dual Fuel- Series Dual Fuel Range Top Parts List for Model DF Ref # Part # Description 0 Grate, Burner W/Rubber Pad 0 Burner Cap Assy, Sml 0 Burner Head 0 Venturi, Small