1 WATER QUALITY ANALYZERS ORP SENSOR TECHNOLOGY Conductivity DO Temperature Resistivity
2 WaterQuality(E)出力用 :12 PM ページ1 ELECTRODE LINE UP NEW Sleeve D Precious, trace amount sample 3-in-1 3-in-1 Sleeve D 3-in-1 Micro D (Combination) For Test Tubes For Test Tubes For Food D D Analysis D Standard C For Extra-Thin Test Tubes C Protein, high viscosity application General laboratory application (3-in-1) Needle Type C Flat Type C D ORP Temperature Metalic Platinum 3-in-1 Type D Temperature T Conductivity Immersion Type D Immersion Type D Dissolved Oxygen Immersion Type Immersion Type D D 1 Flow Type D Flow Type D Flow Type C Flow Type C Field Use D Field Use D (2 m Cable) (10 m Cable) Laboratory Use D
3 electrode just got Touer! Enhanced durability of the glass membrane makes it four times stronger than the conventional Tou electrode. The patented silver ion trap technology improves response time. The response time is 40 times faster than the conventional electrodes. 10 Pin hole to Teflon coating Ion exchange material to minimize Ag + spill Ceramics Liquid junction Reference electrode response time over 3 months (tap ). Response glass mv Tou Conventional electrode Tap, pure application Non-glass electrode for food application, etc time(s) With enhanced durability, the electrode is more easily maintained with a sponge or optional cleaning reagent. 3-in-1 Plastic D ISFET D ISFET Tou Glass Conventional Glass Cyanide Ion C Chloride Ion (Combination Type) C Chloride Ion C Sulfide Ion C Iodide Ion C Bromide Ion C Copper Ion C Cadmium Ion C Lead Ion C Thiocyanate Ion C Fluoride Ion (Combination Type) C CN - CI - CI - S 2- I - Br - Cu 2+ Cd 2+ Pb 2+ SCN - F - Fluoride Ion C Silver Ion C Ammonia (Combination Type) 5002A-10C Sodium Ion 1512A-10C Nitrate Ion (Combination Type) C Nitrate Ion C Potassium Ion (Combination Type) C Potassium Ion C Calcium Ion (Combination Type) C Calcium Ion C F - Ag + NH3 Na + NO3 - NO3 - K + K + Ca 2+ Ca 2+ 2
4 LABORATORY ORP F-50 Series DS-50 Series Conductivity Temperature Resistivity Screen images are superimposed. Standard meter with custom LCD display Color LCD display with navigation function Two channels meter with, ORP and measurement, color LCD display with navigation function Economical, ORP and conductivity meter with custom LCD display F-51BW F-52 F-53 ORP Battery operation possible ORP CH.1 CH.2 ORP ORP Compact flash F-54BW ORP COND Battery operation possible 3
5 Color display and navigation function for enhanced user-friendliness. The world s first 5.7 inch wide screen with color display. Just press "Navi" key For operation or troubleshooting menus Option Enhanced data reliability with validation feature. (GLP/GMP compliance) Self diagnostic features and optional printer assures data reliability. Printer (For GLP/GMP compliance) Printer Cable Part No ( ) Benchtop multi-parameter meter allows measurement of up to 4 parameters. Electronic record, audit trail and electronic signatures are security function features. (FDA 21CFR Part11 compliance) Data can be transferred to a PC by compact flash, Ethernet and/or serial connection. Digital Simulator X-51(, ORP,, DO,TEMP) X-52(COND,TEMP) Two channels meter with, ORP and conductivity measurement. Color LCD display with navigation function. World's first meter with FDA 21CFR Part11 support measures, ORP, conductivity and. Standard conductivity meter with custom LCD display Enhanced conductivity meter with color LCD and navigation function. F-54 CH.1 ORP COND RESI CH.2 Compact flash F-55 DS-51 CH.1 CH.2 ORP COND RESI Compact flash Ethernet COND RESI Battery operation possible Set includes conductivity electrode. (model D) DS-52 COND RESI Set includes conductivity electrode. (model D) 4
6 Economical meter for and temperature Multi-parameter for /temperature/orp with PC/printer output capability. Multi-parameter for /temperature/orp/ with PC/printer output capability D-51 D-52 D-53 ORP ORP FIELD ORP D-50 Series ES-51 OM-51 Conductivity Temperature Resistivity DO 5
7 Multi-parameter for /temperature/orp/ conductivity with PC/printer output capability Multi-parameter for /temperature/orp/ dissolved oxygen with PC/printer output capability Portable conductivity/resistivity/ salinity meter with PC/printer output Portable dissolved oxygen meter with PC/printer output D-54 D-55 ORP ES-51 COND ORP DO COND RESI Set includes conductivity electrode. (model D) OM-51 DO Select from the followings. 2 m cable (OM-51-2) 10 m cable (OM-51-10) Laboratory (OM-51-L1) (BOD measurement) Revolutionary meter and electrodes enhance care-free operation in the lab or field. HORIBA portable meter conforms to standard of IEC529:IP67. Quick connection to PC allows easy and fast data evaluation. electrode (model D) is down to depth of 1m. DO electrode (model D, D) is down to depth of 10m. Option Digital Simulator X-51(, ORP,, DO,TEMP) X-52(COND,TEMP) Portable multi-parameter meter allows measurement of D-51 up to 4 parameters. with ORP D-52 COND DO with D-53 with Conductivity D-54 with Dissolved Oxygen D-55 Stand Part No ( ) Automatic data-logging function. Store up to 300 sets of data automatically. Self diagnostic function assures reliable measurement. User-friendly self-diagnostic modes for battery voltage, temperature, calibration and LCD checks. User-friendly features and portability with large LCD display. 6
8 Measurement method Measurement range Repeatability Power supply Mass Conductvity Resistance mv(orp) Temperture Conductvity Resistance mv(orp) Temperture Conductvity Resistance F-50 series / DS-50 series Specifications F-51BW F-52 F-53 F-54BW F-54 F-55 ORP ORP Battery operation possible ±0.01 ±1digit ±1mV ±1digit RS232C printer output ±0.001 ±1digit ±0.1mV ±1digit DC6V (LR6 dry cell battery) AC adapter AC adapter 100 ~ 240V 50/60Hz 100 ~ 240V 50/60Hz approx. 1O approx. 1.1O CH.1 CH.2 ORP ORP Compact flash Ion electrode method ±0.001 ±1digit ±0.1mV ±1digit ±0.5%F.S. ±1digit ORP COND Battery operation possible ±0.001 ±1digit ±1mV ±1digit CH.1 CH.2 ORP COND RESI Compact flash CH.1 CH.2 ORP COND RESI Compact flash Ethernet Ion electrode method AC bipolar method ~ Resolution 0.01/ ~ Resolution 0.1mV AC bipolar method AC bipolar method 0.00 ~ Resolution ~ Resolution 0.01/ ~ Resolution 0.01/ ~ Resolution ~ Resolution 0.01/ ~ ~ ~ ~ ~ Resolution 1mV Resolution 0.1mV Resolution 0.1mV Resolution 1mV Resolution 0.1mV 0.0 ~ 100.0: Resolution 0.1: 0.0 ~ 100.0: Resolution 0.1: 0.0 ~ 100.0: Resolution 0.1: 0.0 ~ 100.0: Resolution 0.1: 0.0 ~ 100.0: Resolution 0.1: 0.0 ~ 100.0: Resolution 0.1: 0.0µ ~ 999g/L (mol/l) 0.0µ ~ 999g/L (mol/l) 0.00 ~ 4.00% Resolution 0.01% : 0.05½ám ~ 199.9k½ám : 0.5½ám ~ 1.999M½ám : 0.005½ám ~ 19.99k½ám ±0.001 ±1digit ±0.1mV ±1digit 0.00 ~ 4.00% Resolution 0.01% : 0.05½ám ~ 199.9k½ám : 0.5½ám ~ 1.999M½ám : 0.005½ám ~ 19.99k½ám ±0.001 ±1digit ±0.1mV ±1digit ±0.5%F.S. ±1digit AC adapter 100 ~ 240V 50/60Hz AC adapter DC6V (LR6 dry cell battery) AC adapter 100 ~ 240V 50/60Hz AC adapter 100 ~ 240V 50/60Hz 100 ~ 240V 50/60Hz approx. 1.1O approx. 1O approx. 1.1O approx. 1.1O 7 Measurement method Measurement range Repeatability Power supply Mass Conductvity Dissolved Oxygen Resistance Saturation Oxygen Oxygen Temperture mv(orp) Conductvity Dissolved Oxygen Resistance Saturation Oxygen Oxygen Temperture mv(orp) Conductvity Dissolved Oxygen Resistance D-50 series / ES-51 / OM-51 Specifications D-51 D-52 D-53 D-54 D-55 ES-51 ORP ORP ORP COND ORP DO COND RESI 0.00 ~ Resolution ~ 100.0: Resolution 0.1: 0.0 ~ 100.0: Resolution 0.1: 0.0 ~ 100.0: Resolution 0.1: ~ 1999 Resolution 1mV ~ 1999 Resolution 1mV 0.0µ ~ 999g/L (mol/l) ±0.01 ±1digit approx. 300g Ion electrode method AC bipolar method Diaphragm galvanic battery method AC bipolar method 0.00 ~ Resolution 0.01 ±0.01 ±1digit ±1mV ±1digi approx. 300g 0.00 ~ Resolution 0.01 ±0.01 ±1digit ±1mV ±1digi ±0.5%F.S. ±1digit approx. 330g 0.00 ~ Resolution ~ 100.0: Resolution 0.1: ~ 1999 Resolution 1mV ±0.01 ±1digit ±1mV ±1digit ±0.5%F.S. ±1digit approx. 330g 0.00 ~ Resolution ~ 100.0: Resolution 0.1: 0.0 ~ 100.0: Resolution 0.1: ~ 1999 Resolution 1mV 0.00 ~ 19.99mg/L Resolution 0.01mg/L ±0.01 ±1digit ±1mV ±1digit ±0.1mg/L ±1digit approx. 330g : 5.00½ám ~ 199.9k½ám : 50.0½ám ~ 1.99M½ám : 0.500½ám ~ 19.99k½ám 0.00 ~ 4.00% Resolution 0.01% ±0.5%F.S. ±1digit ±0.5%F.S. ±1digit approx. 300g
9 DS-51 COND RESI COND RESI Battery operation possible AC bipolar method 0.0 ~ 100.0: Resolution 0.1: : 0.05½ám ~ 199.9k½ám : 0.5½ám ~ 1.999M½ám : 0.005½ám ~ 19.99k½ám DC6V (LR6 dry cell battery) AC adapter 100 ~ 240V 50/60Hz approx. 1O OM-51 DO Diaphragm galvanic battery method Dissolved Oxygen conversion Dissolved Oxygen conversion 0.0 ~ 100.0: Resolution 0.1: 0.00 ~ 19.99mg/L Resolution 0.01mg/L 0.0 ~ 199.9% Resolution 0.1% 0.0 ~ 50.0% Resolution 0.1% ±0.1mg/L ±1digit approx. 300g DS-52 AC bipolar method 0.0 ~ 100.0: Resolution 0.1: 0.00 ~ 4.00% Resolution 0.01% 0.00 ~ 4.00% Resolution 0.01% : 0.05½ám ~ 199.9k½ám : 0.5½ám ~ 1.999M½ám : 0.005½ám ~ 19.99k½ám AC adapter 100 ~ 240V 50/60Hz approx. 1.1O Line up Name Model Description Temp.range(:) range Part No. (Old No.) D Water thick membrane type 0~ 80 0~ ( ) D Protein, high viscosity type 0~ 60 0~ ( ) D Precious, trace amount sample type 0~ 60 0~ ( ) 3-in-1 electrode D Plastic body 0 ~ ~ ( ) D Sleeve 1 0~ 60 0~ ( ) D For test tubes 1 0~ 60 0~ ( ) Combination D For test tubes 0 ~ ~ ( ) electrode D For food analysis 1 0~ 60 0~ ( ) C Standard 0 ~ 100 0~ ( ) C For extra-thin test tubes 0~ 60 0~ ( ) C Needle type 0~ 50 0~ ( ) C Flat type 0~ 50 0~ ( ) ISFET electrode D Needle type ISFET 0~ 60 0~ ( ) ORP electrode D Platinum 3-in-1 type 0~ ( ) Temperature electrode T For temperature compensation and measurement 0 ~ ( ) 1 Do not use this electrode with other electrodes, as it will interfere the measurement value : when completely immersed. Conductivity Line up Cell constant m -1 (cm -1 ) 10 (0.1) Immersion 100 (1) type 100 (1) Conductivity 1000 (10) electrode 10 (0.1) 100 (1) Flow type 1000 (10) 1000 (10) Ion Line up Model D D D D D D C C Range m -1 (cm -1 ) 10µS ~ 1S (0.1µS ~ 10mS) 0.1mS ~ 10S (1µS ~ 100mS) 0.1mS ~ 10S (1µS ~ 100mS) 1mS ~ 100S (10µS ~ 1S) 10µS ~ 1S (0.1µS ~ 10mS) 0.1mS ~ 10S (1µS ~ 100mS) 1mS ~ 100S (10µS ~ 1S) 1mS ~ 10S (10µS ~ 100mS) Samples req'd(ml) 50 20~ Temp. range(:) Part No. (Old No.) 0 ~ ( ) 0~ ( ) 0 ~ ( ) 0 ~ ( ) 0 ~ ( ) 0 ~ ( ) 0 ~ ( ) 0~ ( ) Please be aware of the hindering ion and range interference of ion electrodes. name Model Measuring range Applicable reference electrode Part No. (Old No.) Cyanide ion electrode Chloride ion electrode (Combination type) Chloride ion electrode Sulfide ion electrode Iodide ion electrode Bromide ion electrode Copper ion electrode Cadmium ion electrode Lead ion electrode Thiocyanate ion electrode Fluoride ion electrode (Combination type) Fluoride ion electrode Silver ion electrode Ammonia electrode (Combination type) Sodium ion electrode Nitrate ion electrode (Combination type) Nitrate ion electrode Potassium ion electrode (Combination type) Potassium ion electrode Calcium ion electrode (Combination type) Calcium ion electrode Chloride ion tip Fluoride ion tip Nitrate ion tip Potassium ion tip Calcium ion tip Ammonia electrode membrane (6pcs) C C C C C C C C C C C C C 5002A-10C 1512A-10C C C C C C C membrane(nh3) 0.03 ~ 2,600 ppmcn ~ 35,000 ppmci ~ 35,000 ppmci ~ 32,000 ppms ~ 13,000 ppmi ~ 80,000 ppmbr ~ 6,400 ppmcu ~ 11,000 ppmcd 2+ 2 ~ 20,000 ppmpb ~ 5,800 ppmscn ~ 19,000 ppmf ~ 19,000 ppmf ~ 110,000 ppmag ~ 1,000 ppmnh3 2.3 ~ 230,000 ppmna ~ 62,000 ppmno ~ 62,000 ppmno ~ 39,000 ppmk ~ 39,000 ppmk ~ 40,080 ppmca ~ 40,080 ppmca A 2060A 2060A 2060A 2060A 2060A ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) D-53 can use only combination type ion electrode. DO electrode / DO Tip Line up Water DO electrode Water DO electrode DO electrode DO tip DO tip Lead length 2m 10m 1m Model D D D Specification Field immersible type Field immersible type Laboratory use Replacement electrode tip for 9551 Replacement electrode tip for 9520 Temp. range(:) 0 ~ 40 0 ~ 40 0~45 Part No. (Old No.) ( ) ( ) ( ) ( ) ( ) 8
10 Water Quality MONITORING SYSTEM W-20XD Series The W-20XD Series: Same Innovative features, now with Xtra Durable design Heavy-duty stainless steel protective cover Rubber-made sensor guard to protect sensors and prevent contamination Control Unit Murti-Probe Up to one month Data logging "Simply leave the probe submerged in the sample and the sensor's builtin memory function enables continuous measurement for up to one month.* Personnal do not need to be present duringthe measurement process. Data can even be retrieved by personal computers in remote locations." Simultaneous measurement of 13 parameters With the W-23XD unit (only), simultaneous measurements of up to 13 parameters (from, dissolved oxygen, and conductivity to sea specific gravity and a variety of ions) can be obtained ÐÐÐ much more quickly and easily than with conventional instruments. With its powerful measurement capabilities, the compact W-20XD series is recommended for all quality researchers and professionals. Measurement at depths as low as 100 meters With its superior durability and high pressure resistance, the newly developed sensor facilitates measurements as far as 100 meters below the surface. Thus, in addition to rivers, lakes and other shallow bodies, high-precision measurement can now be readily obtained ÐÐÐ and quality can be monitored ÐÐÐ at dams, and even in the open sea. W-22XD sensor Dissolved oxygen sensor (replaceable) W-23XD sensor Dissolved oxygen sensor (replaceable) /ORP sensor (replaceable) Depth sensor /ORP sensor (replaceable) Conductivity/temperature/ turbidity sensors Depth sensor Ion sensors (replaceable) Conductivity/temperature/turbidity sensors 9
11 Measure and Display 11 Parameters Simultaneously with Innovative Features, Newly Designed Control Unit and Sensor Technology. Intuitive software assures ease of use and operation efficiency. Experience the durability and performance of an instrument that exceeds your expectations in the field testing of ground and surface applications. Measure and Display up to 11 Items Simultaneously Control Unit Features: Easy to read LCD Display One-hand operation On-screen icon displays battery power and GPS, USB and probe unit connectivity Quick-connect connector (cable to control unit) Shock resistant cover Backlight display COMPACT METER Immersion, scoop, and flat measurement. B-211 B-212 B-213 Measurement method Measurement range 2 ~ 12 Repeatability ±0.1 Power supply Two 3-volt lithium batteries Mass approx. 53g. COMPACT CONDUCTIVITY METER COND Two measurement methods: drop the sample on the sensor or immerse the sensor in the sample. B-173 Measurement method Measurement Conductvity range Temperture Repeatability Power supply Mass single-point 7 Auto Calibration Two point 7/4 Auto Calibration Two point 7/4 Auto Calibration AC bipolar method 0 ~ 19.9mS/cm 0 ~ 1.1% 5~35: ±1% full scale Two 3-volt lithium batteries 46g NIST standard Solution NIST standard Solution US standard Solution Operatinginstructions Rugged Outdoor Design COMPACT NITRATE METER HORIBA's flat sensor enables easy measurement with only a few drops of sample. Measurement method Measurement - NO3 range - NO3 -N - NO3 -N Repeatability Power supply Mass CARDY Series B-341 (for crops) 100 to 9900 (ppm or mg/l) 23 to 2200 (ppm or mg/l-n) With soil/ samplingratio of 1:5. UsingHORIBA's prescribed method NO3 - B-341 (for crops) B-342 (for soil) B-343 (for general use) B-342 (for soil) Ion electrode method 30 to 600 (ppm or mg/l) 6.8 to 140 (ppm or mg/l-n) 3.4 to 68 (kg/10a) ±10% CR2032 batteries (x2) Approx.52g(meter onry) B-343 (for general use) 62 to 6200 (ppm or mg/l) 14 to 1400 (ppm or mg/l-n) Sensor Probe Unit Features: Ultra-sensitive Turbidity Sensor Minimum dissolved oxygen sensor maintenance with screw-on type membrane cap Chemical resistant materials of construction Optional Tou electrode* that is difficult to break Field replaceable sensors *Prevents damage during maintenance. Compact & meters Measurement range Sample amount required Sample temperature Liquid junction Mass C-121/122 (NaCl/Na + ) Na + Ion meter C-122 K + Ion meter C-131 meter C-121 C-131 (K + ) Na + K + NaCl 0.1%(w/w) ~ 10%(w/w) NaCl 39 ~ 3900ppm 23 ~ 2300ppm Na approx. 0.1ml approx. 0.1ml 5~35: 5~35: Porous macromolecle Porous macromolecle Approx. 40 g 10
12 Dimesional Outlines Unit: mm(in) F-50 Series / DS-50 Series 374(14.7) D-50 Series / ES-51 / OM (7.0) 80(3.1) 40(1.6) 230(9.1) 339(13.3) 170(6.7) 68(2.7) 30 (1.2)
13 Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0) Fax: +44 (0) Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.
water proof water proof Tap water, pure water application Precious, trace amount sample 3-in-1 Plastic Electrode D
ELECTRODE LINE UP electrode just got Touer! Enhanced durability of the glass membrane makes it four times stronger than the conventional Tou electrode. Response glass NEW The patented silver ion trap technology
More informationWATER QUALITY ANALYZERS SENSOR TECHNOLOGY. Customer Registration System. Dimesional Outlines Unit: mm(in) ORP ION. Conductivity.
Dimesional Outlines Unit: mm(in) F-50 Series / DS-50 Series 374(14.7) D-50 Series / ES-51 / OM-51 179(7.0) 80(3.1) 40(1.6) 230(9.1) 339(13.3) 170(6.7) CE marking compliant 68(2.7) 30 (1.2) Customer Registration
More informationWATER QUALITY ANALYZERS SENSOR TECHNOLOGY. ORP ION. Conductivity. Temperature. Resistivity SALT
WATER QUALITY ANALYZERS ORP SENSOR TECHNOLOGY Conductivity DO Temperature Resistivity http://www.horiba.com/wq/ WaterQuality(E)出力用 10.6.24 9:12 PM ページ1 ELECTRODE LINE UP NEW Sleeve 6367-10D Precious, trace
More informationph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m
s ph electrodes are constructed from a special composition which senses the hydrogen ion concentration. This is typically composed of alkali metal ions. The alkali metal ions of the and the hydrogen ions
More informationIon-selective Measurements
Ion-selective Measurements Ion-selective measurement is a method for determining the concentration of dissolved ions. Potassium ions, sodium ions, fluoride or chloride are examples of such cations and
More informationConcise laboratory catalogue
2008 Concise laboratory catalogue Portable and bench-top instruments for ph, EC, ISE, DO and C measurements. Simple and advanced models covering from routine measurements to maximum requirements in investigation.
More informationNanotechnology Sensors
ESILAB PACK : 1 Ion + ph Nanotechnology Sensors email : contact@water-kits.fr This revolutionary technology based on carbon nanotubes hugely simplifies the potentiometric measurements. Measurement & calibration
More informationPC100 Handheld ph/cond./tds/sal. Meter. Instruction Manual
PC100 Handheld ph/cond./tds/sal. Meter Instruction Manual Table of Contents 1. Introduction ------------------------------------------------------------------------------------------------------------------------
More informationOne-hand ph/temperature measuring instrument
One-hand ph/temperature measuring instrument testo 205 ph tip embedded in breakage-proof plastic ph Combined penetration tip with temperature probe Maintenance-free gel electrolyte C Measurement tip exchangeable
More informationCompact ph Measuring Instruments With Pro Engineering
testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode ph C The new ph instruments with innovative probe engineering Measurement of the ph
More informationBante900P Portable Multiparameter Water Quality Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD
Bante900P Portable Multiparameter Water Quality Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante900P Portable Multiparameter Water Quality Meter 1 Introduction Thank you for selecting the Bante900P
More informationIon-Selective Measurements
Ion-Selective Measurements Ion-selective measurement is a method for determining the concentration of dissolved ions. Potassium ions, sodium ions, fluoride or chloride are examples of such cations and
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationIon Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015
Ion Selective Electrodes for the Laboratory Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015 Outline Review ISE measurement technology How to properly calibrate
More informationThermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations
Thermo Scientific Orion Star T900 Series Laboratory Titrators Potentiometric titrators for performing automated ph, redox, or ion titrations Thermo Scientific Orion Star T900 Series Titrators Automate
More informationGENERAL INSTRUCTIONS GENERAL PREPARATION
GENERAL INSTRUCTIONS Introduction The Van London-pHoenix Company Fluoroborate Ion Selective Electrode is used to quickly, simply, accurately, and economically measure Fluoroborate in aqueous solutions.
More informationBenchtop Water Quality Meters 1000 Series
ph ORP Ion Conductivity Resistivity Total Dissolved Solids Salinity Benchtop Water Quality Meters 1000 Series METERS 2 YEAR W A R R A N T Y M A D E I N J A P A N www.horiba-laqua.com Benchtop Water Quality
More informationPerfect Electrochemical Analysis Professional Meters Basic Meters Portable Meters Sensors
Perfect Electrochemical Analysis Professional Meters Basic Meters Portable Meters Sensors Highly intelligent technology for electrochemical analyses We don t have to explain the basics of electrochemical
More informationELECTRODES & ACCESSORIES ph(orp) ION CONDUCTIVITY DO
ELECTRODES & ACCESSORIES ph(orp) ION CONDUCTIVITY DO CONTENTS ELECTRODE SELECTION GUIDE, ph METER and ELECTRODE COMBINATION TABLE NEW ELECTORODES (ph ELECTORODES) ph ELECTRODES (GLASS ELECTRODES) ph ELECTORODES
More informationPHS-25CW/3BW Benchtop ph Meter Instruction Manual
PHS-25CW/3BW Benchtop ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD PHS-W Series Benchtop ph Meter 1 Introduction Thank you for selecting the PHS-W series benchtop ph meter. This manual provides
More informationph electrodes with screw cap S7. Special application electrodes.
ph electrodes with screw cap. Special application electrodes. Suitable to cover special applications. 52 07 Flat membrane One drop of distilled water is sufficient to take a measurement 52 08 and 52 09
More informationChemistry MultiMeasure Sensor PS-2170
ä 5 Instruction Manual 012-09523A Chemistry MultiMeasure Sensor PS-2170 ph/ise/orp PRESSURE CHEMISTRY TEMPERATURE SENSOR VOLTAGE 1 2 3 4 PS-2170 5 6 7 cc 8 10 15 20 25 30 35 40 45 50 55 60 Included Equipment
More informationUnauthorized reprinting or copying of this operation manual
Preface Thank you for purchasing one of the D-50 Series ph meters. This meter is designed with a compact body that can be held in one hand and features a water-resistant construction Note 1. It has a large-sized
More informationGENERAL INSTRUCTIONS GENERAL PREPARATION
GENERAL INSTRUCTIONS Introduction The Van London-pHoenix Company Ammonium Ion Selective Electrode is used to quickly, simply, accurately, and economically measure potassium in aqueous solutions. Required
More informationRapid RH Portable ph Meter. User's Manual
Rapid RH Portable ph Meter User's Manual This page intentionally left blank. 2 Contents 1. Introduction... 4 2. Included with the Rapid RH Portable ph Meter... 4 3. Understanding ph... 5 4. Calibrating
More informationAll about ph! Is it as simple as it seems? The ph Workshop. Rick Noone Thermo Scientific Water Analysis Instruments, Orion products May 22, 2014
All about ph! Is it as simple as it seems? The ph Workshop Rick Noone Thermo Scientific Water Analysis Instruments, Orion products May 22, 2014 Common Questions: Measuring ph What is ph? Potential Hydrogen
More informationThermo Scientific Orion Fluoride Ion Selective Electrodes The standard in fluoride ion analysis EPA compliant
Thermo Scientific Orion Fluoride Ion Selective Electrodes The standard in fluoride ion analysis EPA compliant Approved ASTM Method for Fluoride in Drinking Water and Wastewater Analyze free fluoride ions
More informationIon Selective Electrodes
Ion Selective Electrodes A n a l y t i c a l S e n s o r s & I n s t r u m e n t s I O N S E L E C T I V E E L E C T R O D Ion Selective Electrodes (ISE) are membrane electrodes that respond selectively
More informationUser s Guide. Waterproof Palm ph Meter Model PH220. Introduction
User s Guide Waterproof Palm ph Meter Model PH220 Introduction Congratulations on your purchase of the Extech PH220 waterproof ph/mv meter. This microprocessor-based device with tactile buttons is battery
More informationtesto 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode Draft Version
testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode Draft Version ph C The new ph measuring instruments with innovative probe engineering
More informationAppendices towards the Operation Manual of Ultrasonic milk analyzer Lactoscan
APPENDIX 7 PH MEASURING 1. General information PH probe is a unit, measuring the solution acidity or alkalinity degree. It is measured on scale of 0 to 14. The term ph is derived from "p", the mathematical
More informationF- Cl- Br- I- CN- S2- NO3-
Middle of the 60 s First ISE for fluoride Na+ K+ Ag+ Ca2+ NH + 4 Cu2+ Pb2+ F- Cl- Br- I- CN- S2- NO3- Environment Food industry and agriculture Medecine, pharmaceutical, cosmetics Power plants Fluoride
More informationBante210 Benchtop ph Meter Instruction Manual
Bante210 Benchtop ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante210 Benchtop ph Meter 1 Introduction Thank you for selecting the Bante210 benchtop ph meter. This manual provides a step-by-step
More informationPHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD
PHS-25CW/3BW Benchtop ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD PHS-W Series Benchtop ph Meter 1 Introduction Thank you for selecting the PHS-W series benchtop ph meter. This manual provides
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS Model IQ120 and IQ125 Professional ph Meter with Silicon Chip Sensor (IQ125 additional instructions printed in RED) IQ Scientific Instruments 2075-E Corte del Nogal Carlsbad, CA
More informationsymphony Multisensor Probes
DOC022.53.80319 symphony Multisensor Probes 07/2012, Edition 1 User Manual Table of contents Safety information on page 3 Calibration on page 6 Specifications on page 3 Sample requirements on page 8 Product
More informationGuide to ph Analysis.
Guide to ph Analysis. XX Why Contents ph Matters Table of Contents Why ph Matters pg 4 What You Need pg 6 How to Measure pg 14 Slope and offset pg 18 Checklist pg 20 Best Practices pg 21 2 Guide to ph
More informationKEM SET. for Beverage. Gas volume Internal gas pressure Air content Oxygen concentration Inside pressure Density Brix
Acidity Alkalinity for Beverage Gas volume Internal gas pressure Air content Oxygen concentration Inside pressure Density Brix Vitamin C Ca & Mg Acidity Vitamin C for Ca & Mg Ca Mg Alkalinity A Automatic
More informationReagents for Chemical Test Kits
for Chemical Test Kits Acidity, methyl orange method ; 0 to 500 mg/l HI 3820-100 Reagent kit for 110 tests (CaCO 3 ) Acidity, olive oil, titration with hydroxide 0.00 to 1.00% HI 3897 Reagent kit for 6
More informationINE-DDB-303A Portable Conductivity Meter Instruction Manual
INE-DDB-303A Portable Conductivity Meter Instruction Manual Operation ManualPLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com,3
More informationSalicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832
, TNTplus 832, 10205 DOC316.53.01083 Salicylate Method Method 10205 HR (2 to 47 mg/l NH 3 N) TNTplus 832 Scope and Application: For surface waters, municipal and industrial wastewaters. Test preparation
More informationph electrode Instruction Manual For use with the RAH-210 & RPH-250
ph electrode Instruction Manual For use with the RAH-210 & RPH-250 The information in this manual was current at the time of printing. The most current versions of all Hydro Instruments manuals can be
More informationEdgetech Instruments Inc.
2015_07_ETI OVERVIEW Rev 3 MADE IN THE USA Edgetech Instruments (ETI) is a USA company based in Massachusetts. We have over 50 years of expertise in the design and manufacture of a comprehensive range
More informationCOLE-PARMER INDUSTRIAL POTASSIUM ION ELECTRODE INSTRUCTION MANUAL
COLE-PARMER INDUSTRIAL POTASSIUM ION ELECTRODE INSTRUCTION MANUAL Cole-Parmer Instrument Company (800)323-4340 Fax:(847)247-2929 625 East Bunker Court, Vernon Hills, Illinois 60061 http://www.coleparmer.com
More informationTOP Offers Special Measuring Instruments
TOP Offers Special Measuring Instruments conductivity oxygen tester CHK By Dostmann. Handy digital tester for measuring the value. Permanently connected combination electrode Automatic calibration and
More informationORP Probe. Mini ORP. Reads. +/-2000mV. Range SMA. Connector. 95% in 1s. Response time 100 PSI. Max pressure. 60m (197 ft) Max depth 1 80 C
Mini V 1.3 Revised 1/10/19 ORP Probe Reads Range Connector Response time Max pressure Max depth Temperature range C Cable length Internal temperature sensor Time before recalibration Life expectancy Maintenance
More informationDigital Dissolved Oxygen, Conductivity, TDS and ph Meter
User's Guide Digital Dissolved Oxygen, Conductivity, TDS and ph Meter Model DO700 Introduction Congratulations on your purchase of the Extech DO700 meter. For best results, please read the entire manual
More informationCOLE-PARMER INDUSTRIAL AMMONIUM ION ELECTRODE INSTRUCTION MANUAL
GENERAL INSTRUCTIONS Introduction COLE-PARMER INDUSTRIAL AMMONIUM ION ELECTRODE INSTRUCTION MANUAL The Cole-Parmer Industrial Ammonium Ion Electrode is used to quickly, simply, accurately, and economically
More informationTHERMYS 150. Advanced field reference thermometer / temperature calibrator
Advanced field reference thermometer / temperature calibrator THERMYS 150 is an all-in-one high accurate documenting field reference thermometer for thermocouples (14 types), resistive probes (12 types)
More informationION SELECTIVE MEASUREMENT
Electrodes Solutions Instrumentation ION SELECTIVE MEASUREMENT catalog featuring our full line of Ion Selective Electrodes Introduction Hanna Instruments Ion Selective Measurement Catalog Authorized Distributor
More informationph / Temperature Meter for Cheese with Application Specific Probe
C/ F ph / Temperature Meter for Cheese with Application Specific Probe ph Application Importance ph is an essential measurement throughout the entire cheesemaking process. From the initial measurements
More informationTitration Sensors. Titration Sensors DS800-TwoPhase DS500 DP5 Phototrode. Titration of a large variety of surfactants Fast, accurate and reliable
Titration Sensors Titration Sensors DS800TwoPhase DS500 DP5 Phototrode Titration of a large variety of surfactants Fast, accurate and reliable TwoPhase Surfactant Titration DS800TwoPhase Superior performance
More informationProcess Instrumentation analyzers
PCA300 Family Chlorine, ph, ORP and Temperature Analyzers Backlit LCD display Nema 4X protection.10 DPD chlorine measurement method Colorimeter diagnostics Reagent reminder Amplified ph/temperature probe
More informationUnderstanding ph Troubleshooting and Diagnostic information
Understanding ph Troubleshooting and Diagnostic information The desire is to achieve an accurate, reliable measurement with a reasonable electrode life expectancy while minimizing frequency or complexity
More informationChloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA
, 10255 DOC316.53.01322 Direct Measurement ISE Method Method 10255 3.55 g/l to 35 g/l Cl Powder Pillow ISA Scope and Application: For the determination of high concentrations (1 M) of chloride in brine
More informationNeoMet. Instruction Manual. istek, Inc. Portable ph/ise/mv/orp, DO/O2/Air, Conductivity/TDS/Salinity/Temp Meter 29D 47C 415CP 815PDC
NeoMet Portable ph/ise/mv/orp, DO/O2/Air, Conductivity/TDS/Salinity/Temp Meter Model 79P 29D 47C 415CP 815PDC Instruction Manual istek, Inc. TABLE OF CONTENTS CHAPTER I. INTRODUCTION...4 ph/ise/mv/orp/temp
More informationPhotometer AL250. Scroll Memory (SM) N.I.S.T Traceability. Highlights
Photometer AL250 10 The AL250 models each offer one test method, while the AL250+ units are programmed for a number of different parameters. The units supply accurate, reproducible results very quickly.
More informationThe design and operational theory of ph electrodes is a very complex subject, explored only briefly here. What is important to understand is that thes
ph measurement A very important measurement in many liquid chemical processes (industrial, pharmaceutical, manufacturing, food production, etc.) is that of ph: the measurement of hydrogen ion concentration
More informationWATER ANALYSIS The ph Value. The Redox Potential. ALMEMO ph and Redox Measurement. The Electrical Conductivity
www.ahlborn.com WATER ANALYSIS The ph Value The ph value is a logarithmic measure for the concentration of the H ions in a hydrous solution and indicates, by a numerical value, whether the solution has
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationSodium Sealed Electrode Sensor Bundle Product Number: ENSOD051
imagine explore learn Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051 Overview Sodium is highly abundant in the lithosphere (Earth s outer shell) where it occurs as rock salt deposits as
More informationThermo Scientific Orion Solutions, Standards and Buffers. The high-quality solutions you need for electrochemistry measurement
Thermo Scientific Orion Solutions, Standards and Buffers The high-quality solutions you need for electrochemistry measurement High-quality solutions deliver correct measurements every time Whether in the
More informationLaboratory Certification Workshop
Laboratory Certification Workshop Debra Waller debra.waller@dep.state.nj.us NJDEP-Office of Quality Assurance (OQA) 609-292-3950 www.state.nj.us/dep/oqa Environmental Laboratory Certification Program (ELCP)
More informationMetso Concentration Measurement 3300
Metso Concentration Measurement 3300 Metso Concentration 3300 Accurate direct in-line measurement The Concentration Measurement is provided with intelligent technology calculating the concentration of
More informationCh. 14. ELECTRODES AND POTENTIOMETRY
Ch. 14. ELECTRODES AND POTENTIOMETRY 14.1 Analytical chemists design electrodes (voltage sensitive to conc. change) galvanic cells ion-selective electrodes ion-sensing field effect transistors potentiometry
More informationDOC /2013, Edition 1. User Manual
DOC022.52.80407 50 49 08/2013, Edition 1 User Manual Table of Contents Specifications...3 General information...3 Safety information...3 Use of hazard information...3 Precautionary labels...4 Product
More informationORP Probe ORP. Reads. +/-2000mV. Range. 95% in 1s. Response time 100 PSI. Max pressure. 60m (197 ft) Max depth 1 80 C. Temperature range C.
V 2.7 Revised 11/8/17 ORP Probe Reads Range Response time Max pressure Max depth Temperature range C Cable length Internal temperature sensor Time before recalibration Life expectancy Maintenance ORP +/-2000mV
More informationElectrodes for ph measurements. - when you need to be sure...
Electrodes for ph measurements - when you need to be sure... Different types Combined Reference Glass Electrode working principle Glass electrode Reference electrode Electrode body Internal reference element
More informationISO-TECH SYSTEM, VARANASI Analysis by ph and ion selective electrodes
ISO-TECH SYSTE, VARANASI-221010 Related link : ph Combination Electrodes Analysis by ph and ion selective electrodes A comparative view of analysis by ph and Ion Selective Electrodes. Types of ISE electrodes.
More informationph Probe Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth 1 99 C
V 2.8 Revised 1/16/18 ph Probe Silver / silver chloride Reads ph Range 0 14 Resolution Response time Max pressure Max depth Temperature range C Cable length Internal temperature sensor Time before recalibration
More information[Agilent Technologies] [Electrochemistry Products] Quick Reference
Overview Using I9121 Ammonia Gas Sensing Probe on 3200I/M This document demonstrates how to use I 9121 Ammonia Gas Sensing Probe on 3200I or 3200 M to measure pn or the concentration of [NH 4 + ]. Applied
More informationDirect Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution
, drinking water, 8359 DOC316.53.01239 Direct Measurement ISE Method Method 8359 0.04 to 4.00 mg/l NO 3 N TISAB Solution Scope and Application: Drinking water Test preparation How to use instrument-specific
More informationph Probe Spear Tip Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth
V 2.4 Revised 3/1/18 Spear Tip ph Probe Silver / silver chloride Reads ph Range 0 14 Resolution Response time Max pressure Max depth Temperature range C Cable length Internal temperature sensor Time before
More informationNO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC
OPERATING MANUAL ba15362e03 10/2014 NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC NITRATE SENSITIVE ELECTRODE NO 500 NO 800 Note The latest version of the present operating manual can be found on the Internet
More informationINSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements
Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements www.milwaukeeinst.com INSTRUCTION MANUAL www.milwaukeeinst.com 1 Instruction Manual MA886 Refractometer for Sodium Chloride
More informationINFRARED THERMOMETER Model : TM-959
LED target light, Emissivity adjustment INFRARED THERMOMETER Model : TM-959 Your purchase of this I N F R A R E D THERMOMETER marks a step forward for you into the field of precision measurement. Although
More informationMeasuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter
Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter Water and Lab Products, Thermo Fisher Scientific Technical Note 505 Key Words Thermo Scientific Orion
More informationInstruction Manual HI Refractometer for Sodium Chloride Measurements
Instruction Manual HI 96821 Refractometer for Sodium Chloride Measurements www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully
More informationCOLE-PARMER INDUSTRIAL NITRATE ION ELECTRODE INSTRUCTION MANUAL
COLE-PARMER INDUSTRIAL NITRATE ION ELECTRODE INSTRUCTION MANUAL GENERAL INSTRUCTIONS Introduction The Cole-Parmer Industrial Nitrate Ion Electrode is used to quickly, simply, accurately, and economically
More informationHI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL
HI96821 Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully before using this
More informationDimethylphenol Method Method to mg/l NO 3 N or 1.00 to mg/l NO
Nitrate DOC316.53.01070 Dimethylphenol Method Method 10206 0.23 to 13. NO 3 N or 1.00 to 60.00 mg/l NO 3 (LR) TNTplus 835 Scope and application: For wastewater, drinking water, surface water and process
More informationAmmonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A
imagine explore learn Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A Overview Ammonium ions (NH 4+ ) can be found in fertilizer, cleaning products, processed meats and in the waste of
More informationColorimetric Method Method to 0.70 mg/l Ag Powder Pillows
Silver DOC316.53.01134 Colorimetric Method Method 8120 0.02 to 0.70 mg/l Ag Powder Pillows Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows
More informationINE-PHS-3E ph Meter Operating Manual
INE-PHS-3E ph Meter Operating Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.12.16 ADVICE: Read this instruction
More informationINSTRUCTION MANUAL. Type: ORP500 C, ORP500 CD, ORP222 CD, ORP223 CD EN Introduction Helpful Operating Tips. 2
ORP/Reference Electrodes INSTRUCTION MANUAL Type: ORP500 C, ORP500 CD, ORP222 CD, ORP223 CD EN 02-05 Table of Contents 1. Introduction. 2 2. Helpful Operating Tips. 2 3. Calibration Procedure 3 3.1. Laboratory
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationKEM SET. for FOOD. Salinity. Brix Density Concentration. Acid Value POV. Water Content
Salinity for FOOD Brix Density Concentration Acid Value POV Water Content Vitamin C Acid Value / POV Salinity Vitamin C for FOOD A Automatic Potentiometric Titrator B Automatic Potentiometric Titrator
More informationDimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856
Nickel DOC316.53.01065 Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows
More informationVaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance
Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 Fast Response - Low Maintenance DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand- Held Dewpoint Meter DM70 offers accurate
More informationHI HI 8633 HI HI 8734 HI
1 Instruction Manual HI 8033 - HI 8633 HI 8733 - HI 8734 HI 933000 Portable Multi-Range Conductivity/TDS Meters Dear Customer, Thank you for choosing a Hanna Product. Please read this instruction manual
More informationChromazurol S Method Method to 0.50 mg/l Al TNTplus 848
Aluminum DOC316.53.01004 Chromazurol S Method Method 10215 0.02 to 0.50 mg/l Al TNTplus 848 Scope and application: For drinking water, surface water, swimming pool water, wastewater and process analysis.
More informationOPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000
3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a
More informationApplications of Ion-Selective Electrodes
Applications of Ion-Selective Electrodes Analyte Ammonia Carbon dioxide Chloride Chlorine residual Cyanide Fluoride Nitrate Nitrogen oxide/nitrite Oxygen, dissloved Sulfide Electrode type Gas sensing Gas
More informationUser Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration
User Manual Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio with NIST-Traceable Calibration Model 20250-09 THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense
More informationIonmeters. 1. separate ion-selective electrode and reference electrode. 2. combined ion-selective electrode with built-in reference electrode
Ionmeters Ion-Selective Measurements Determination of Lead (Pb 2+ ) Bromide (Br - ) Cadmium (Cd 2+ ) Calcium (Ca 2+ ) Chloride (CI - ) Cyanide (CN - ) Fluoride (F - ) Iodide (I - ) Potassium (K+) Copper
More informationCHEMICALS & REAGENTS
BUFFER SOLUTION, ph 1.68 B-41 3.8 14.45 21.60 64.90 BUFFER SOLUTION, ph 2.00 ± 0.02 B-42 3.8 BUFFER SOLUTION, ph 4.00 ± 0.02 Color coded red BUFFER SOLUTION, COLORLESS, ph 4.00 (ph 4.00 ± 0.02 - Colorless
More informationISEmax CAS40D. Technical Information
Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor
More informationTemperature measurement
Temperature measurement 19 2 Example of connections of particular elements Temperature display units BGK85 (page 31) Option Computer, control, itp. Temperature measurement TFC TFL (page 23) (page 23) Temperature
More information1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration
1551A Ex/155A Ex Intrinsically Safe Stik Thermometer The new gold standard of industrial temperature calibration Designed to go where you work Finally, a digital substitute for your mercury-in-glass thermometers!
More informationDesigned to go where you work
Designed to go where you work Finally, a digital substitute for your mercury-in-glass thermometers! Accurate and repeatable to ± 0.05 C over its full range, the 55A/55A Stik Thermometer is the new gold
More information