TOP Offers Special Measuring Instruments

Size: px
Start display at page:

Download "TOP Offers Special Measuring Instruments"

Transcription

1 TOP Offers Special Measuring Instruments conductivity oxygen tester CHK By Dostmann. Handy digital tester for measuring the value. Permanently connected combination electrode Automatic calibration and temperature compensation HOLD function Battery status display Measurement range Installed length Shaft Ø Shaft material Storage solution Protection rating 0 to 14 0 to +50 0,1 0,5 ±0,1 ±1 1/2/3point calibration 115 mm 12 mm Plastic 3 M KCI IP65 Delivery incl. batteries. Storage solution and buffer solutions, please order separately. HPC ,15 32,10 Carl Roth GmbH + Co. KG Schoemperlenstr Karlsruhe Valid from 1 October to 31 December 2018 Phone: / Fax: / info@carlroth.com Internet: For ordering and information about prices and delivery in your country please contact us or your local distributor. Contact: All supplies and deliveries are subject to the terms and conditions of sale and delivery of Carl Roth GmbH + Co. KG, Karlsruhe. GB_INT

2 Laborbedarf Testers By Dostmann. Large LCD display Waterproof and dustproof in accordance with protection class IP67 Automatic temperature compensation/correction from 0 to +50 Confirmation when a stable measured value is reached Automatic calibration with display of the calibrated ranges Multicolour back lighting for status display of measurement mode, calibration and alarm (exception: COND 1) a b Conductivity testers COND 1 and COND 5 Model a COND 1 b COND 5 Measurement range 0 to 20 ms/cm 0 to 10 ppt ±20 μs/cm (0 to 1999 μs/cm) ±0,2 ms/cm (2 to 20 ms/cm) ±2 ppm (0,1 to 199,9 ppm) ±20 ppm (200 to 1999 ppm) ±0,1 ppt (2,00 to 10,00 ppt) 0 to 20 ms/cm 0 to 10 ppt 0 to 10 g/l 0 to +50 0,1 ±2 μs/cm (0 to 199,9 μs/cm) ±20 μs/cm (200 to 1999 μs/cm) ±0,2 ms/cm (2 to 20 ms/cm) ±2 ppm (0,1 to 199,9 ppm) ±20 ppm (200 to 1999 ppm) ±0,1 ppt (2,00 to 10,00 ppt) ±2 mg/l (0,1 to 199,9 mg/l) ±0,1 g/l (2,00 to 10,00 g/l) ±0,2 1/2point calibration 1/2/3point calibration Replaceable no yes electrode Reference / +25 temperature Dimension (L x Ø) 175 x 35 mm Delivery incl. conductivity solutions (1413 μs/cm and 12,88 ms/cm), storage case and batteries. Type a COND 1 HPC ,70 69,65 b COND 5 HPC ,45 104,60 Combi tester PC 5 Measurement range 2 to 16 ± to 20 ms/cm 0 to 10 ppt 0 to 10 g/l 0 to +50 0,01 0,1 ±0,01 ±1 ±2 μs/cm (0 to 199,9 μs/cm) ±20 μs/cm (200 to 1999 μs/cm) ±0,2 ms/cm (2 to 20 ms/cm) ±2 ppm (0,1 to 199,9 ppm) ±20 ppm (200 to 1999 ppm) ±0,1 ppt (2,00 to 10,00 ppt) ±2 mg/l (0,1 to 199,9 mg/l) ±0,1 g/l (2,00 to 10,00 g/l)) ±0,2 / 1/2/3point calibration Reference temperature +20 /+25 Dimension (L x Ø) 175 x 35 mm Delivery incl. buffer solutions ( 4,01 and 7,00), conductivity solution (1413 μs/cm), storage solution (3 M KCl), 2 measuring beakers, storage case and batteries. HPK ,45 134,70 2

3 a b Tester kits PH 1, PH 5 and PH 5 food PH 5 food tester with insert electrode for solid and semisolid samples like meat, butter, cheese, yoghurt, dough and creams Type PH1 PH5 PH5 Food Measurement range/ resolution 0,0 to 14,00 ±0,1 2,00 to 16,00 ±1000 0,0 to 50,0 ±0,01 ±1 ±0,5 Replaceable electrode no yes 1/2point calibration 1/2/3point calibration Dimensions Ø x L (mm) 35 x x x 210 Delivery incl. buffer solution ( 4,01 and 7,00), storage solution, storage case and batteries. Image Type a PH 1 EHX ,90 59,65 b PH 5 EHX ,40 94,05 PH 5 Food EHX ,90 199,40 3

4 Laborbedarf Handheld meters By Dostmann. Large LCD display with simultaneous display of measured value and temperature Automatic and manual temperature compensation Confirmation when a stable measured value is reached Automatic calibration with display of the calibrated ranges PC 7+ handheld multimeter Conductivity meter COND 7+ Reference temperature, adjustable cell constant and temperature coefficient Measurement range 0 to 200 ms/cm 0 to 100 g/l 0 to ,1 ±0,4 μs/cm (0 to 19,99 μs/cm) ±4 μs/cm (20,0 to 199,9 μs/cm) ±40 μs/cm (200 to 1999 μs/cm) ±0,4 ms/cm (2,00 to 19,99 ms/cm) ±4 ms/cm (20,0 to 200,0 ms/cm) ±0,2 mg/l (0 to 19,99 mg/l) ±2 mg/l (20,0 to 199,9 mg/l) ±0,2 g/l (2,00 to 19,99 g/l) ±1 g/l (20,0 to 100,0 g/l) ±0,5 Cinch manual 1/2/3/4point calibration 1point calibration (userdefined) Reference temperature +15 to +30 Temperature coefficient 0 to 10,00 % / Cell constant 0,1 / 1,0 / 10 cm 1 Delivery incl. conductivity sensor 2301T (0 to 200 ms/cm, 0 to +60 ), conductivity solutions (1413 μs/cm and 12,88 ms/cm), measuring beaker, storage case and batteries. HPL ,60 276,90 Adjustable reference temperature, cell constant and temperature coefficient Measurement range 0 to 14 ± to 200 ms/cm 0 to 100 g/l 0 to ,1 / 0,01 1 0,1 ±0,01 ±1 ±0,4 μs/cm (0 to 19,99 μs/cm) ±4 μs/cm (20,0 to 199,9 μs/cm) ±40 μs/cm (200 to 1999 μs/cm) ±0,4 ms/cm (2,00 to 19,99 ms/cm) ±4 ms/cm (20,0 to 200,0 ms/cm) ±0,2 mg/l (0 to 19,99 mg/l) ±2 mg/l (20,0 to 199,9 mg/l) ±0,2 g/l (2,00 to 19,99 g/l) ±1g/l (20,0 to 100,0 g/l) ±0,5 Cinch 1/2/3point calibration (predefined buffer) 1/2point calibration (userdefined buffer) 1/2/3/4point calibration (predefined buffer) 1Point calibration (userdefined buffer) Reference temperature +15 to +30 Temperature coefficient 0 to 10,00 % / Cell constant 0,1 / 1,0 / 10 cm 1 Delivery incl. singlerod measuring cell 201T (0 to 14, 0 to +60 ), conductivity sensor 2301T (0 to 200 ms/cm, 0 to +60 ), buffer solutions ( 4,01 and 7,00), conductivity testing solutions (1413 μs/cm and 12,88 ms/cm), storage solution (3 M KCl), measuring beaker, transport case and batteries. HTE ,65 511,70 4

5 7series pocket meter Storage of current calibration and display of the electrode status Technical specifications for meter: measurement range/ resolution Dimensions (H x W x D) manual 0,00 to 14,00 ±1000 0,0 to +100,0 ±0,01 ±1 ±0,5 Cinch (NTC 30 KΩ) 1/2/3point calibration (predefined buffer) 1/2point calibration (userdefined buffer) 196 x 86 x 33 mm Delivery incl. buffer solution 4,01 and 7,00 (per 75 ml), storage solution (35 ml), empty container for water, 100 ml measuring beaker, transport case and batteries. Technical specifications for combination electrodes: electrode 201T GEL 2PoreT range 0 to 14 Operating range () 0 to +60 Diaphragm Ceramic Double Pores Electrolyte / storage solution Gel / 3 mol/l KCl Gel / 3 mol/l KCl Polymer / 3 mol/l KCl Length (mm) Shaft Ø (mm) Shaft material Plastic Temperature sensor NTC 30 KΩ NTC 30 KΩ Application for generally aqueous solutions for insertion measurements in solid and semisolid samples such as meat, fruit, butter, etc. Type Design 7, set 1 combination electrode 201T with integrated temperature sensor HAH ,35 254,35 7, set 2 combination electrode GEL and external temperature sensor NT55 HAH ,70 277,65 7 food, set 3 combination electrode 2PoreT with integrated temperature sensor HAH ,20 292,70 5

6 Laborbedarf Benchtop meters By Dostmann. Large LCD display, backlit with simultaneous display of measured value and temperature Automatic and manual temperature compensation Automatic calibration with display of the calibrated ranges, storage of current calibration Confirmation when a stable measured value is reached Tabletop multimeter PC 52+ Conductivity meter Cond 51+ Reference temperature, adjustable cell constant and temperature coefficient Measurement range 0 to 200 ms/cm 0 to 100 g/l 0 to +100,0 0,1 ±0,4 μs/cm (0 to 19,99 μs/cm) ±4 μs/cm (20,0 to 199,9 μs/cm) ±40 μs/cm (200 to 1999 μs/cm) ±0,4 ms/cm (2,00 to 19,99 ms/cm) ±4 ms/cm (20,0 to 200,0 ms/cm) ±0,2 mg/l (0 to 19,99 mg/l) ±2 mg/l (20,0 to 199,9 mg/l) ±0,2 g/l (2,00 to 19,99 g/l) ±1 g/l (20,0 to 100,0 g/l) ±0,5 Cinch manual 1/2/3/4point calibration 1point calibration (userdefined) Reference temperature +15 to +30 Temperature coefficient 0 to 10,00 % / Cell constant 0,1 / 1,0 / 10 cm 1 Delivery incl. conductivity sensor 2301T (0 to 200 ms/cm, 0 to +60 ), conductivity solutions (1413 μs/cm and 12,88 ms/cm), electrode holder and mains adapter. HXA ,15 398,80 Reference temperature, adjustable cell constant and temperature coefficient Measurement range 0 to 14 ± to 200 ms/cm 0 to 100 g/l 0 to ,01 1 0,1 ±0,01 ±1 ±0,4 μs/cm (0 to 19,99 μs/cm) ±4 μs/cm (20,0 to 199,9 μs/cm) ±40 μs/cm (200 to 1999 μs/cm) ±0,4 ms/cm (2,00 to 19,99 ms/cm) ±0,2 mg/l (0 to 19,99 mg/l) ±2 mg/l (20,0 to 199,9 mg/l) ±0,2 g/l (2,00 to 19,99 g/l) ±1 g/l (20,0 to 100,0 g/l) ±0,5 Cinch 1/2/3point calibration () 1/2point calibration (manual, userdefined) 1/2/3/4point calibration () 1point calibration (manual, userdefined) Reference temperature +15 to +30 Temperature coefficient 0 to 10,00 % / Cell constant 0,1 / 1,0 / 10 cm 1 Delivery incl. single rod measuring cell 201T with integrated temperature sensor (0 to 14, 0 to +60 ), conductivity sensor 2301T with integrated temperature sensor (0 to 200 ms/cm, 0 to +60 ), buffer solutions ( 4,01 and 7,00), conductivity buffer solutions (1413 μs/cm and 12,88 ms/cm), storage solution (3 M KCl), electrode holder and mains adapter. HXC ,40 545,55 6

7 50 benchtop meter Measurement range/ resolution 0,00 to 14,00 ±1999 0,0 to +100,0 ±0,01 ±1 ±0,5 (+5 to +60), ±1 (outside) Cinch (NTC 30 KΩ) 1/2/3point calibration ( 4,01 / 7,00 / 10,01) Data memory 25 measurements, current calibration Dimensions (L x W x H) 160 x 190 x 70 mm Technical specifications for combination electrode 201T: Features integrated temperature sensor, range 0 to 14, operating range 0 to +60, ceramic diaphragm, gelelectrolyte, plastic shaft, shaft length/ø 120/12 mm. Delivery incl. combination electrode 201T, buffer solution 4,01 and 7,00 (50 ml each), electrode holder and mains adapter. HAE ,45 285,20 7

8 Oxygen meter OXY 7 oxygen meter By Dostmann. For determining dissolved oxygen in liquids. Large LCD display with simultaneous display of measured value and temperature Automatic calibration with display of the calibrated ranges Confirmation when a stable measured value is reached Automatic and manual temperature compensation from 0 to +60 Automatic air pressure compensation Manual salinity compensation of 0 to 50 ppt Auto Off after 20 minutes Measurement range O 2 concentration 0 to 50 mg/l O 2 saturation 0 to 400 % Pressure 0 to 1100 mbar 0 to +60,0 O 2 concentration O 2 saturation Pressure 1 mbar 0,1 (with sensor) O 2 concentration ±0,30 mg/l (0,00 to 19,99 mg/l) ±0,75 mg/l (20,0 to 50,0 mg/l) O 2 saturation ±20 % (0,0 to 199,9 %) ±40 % (200 to 400 %) Pressure ±0,55 mbar ±0,5 O 2 Cinch 1/2point calibration Delivery incl. polarographic oxygen sensor OXY DO7 with integrated temperature sensor, electrolyte solution (30 ml), standard zero calibration solution (30 ml), replaceable membrane, storage case and batteries. HPK ,70 488,35 Phone: / info@carlroth.com

One-hand ph/temperature measuring instrument

One-hand ph/temperature measuring instrument One-hand ph/temperature measuring instrument testo 205 ph tip embedded in breakage-proof plastic ph Combined penetration tip with temperature probe Maintenance-free gel electrolyte C Measurement tip exchangeable

More information

Compact ph Measuring Instruments With Pro Engineering

Compact ph Measuring Instruments With Pro Engineering testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode ph C The new ph instruments with innovative probe engineering Measurement of the ph

More information

Perfect Electrochemical Analysis Professional Meters Basic Meters Portable Meters Sensors

Perfect Electrochemical Analysis Professional Meters Basic Meters Portable Meters Sensors Perfect Electrochemical Analysis Professional Meters Basic Meters Portable Meters Sensors Highly intelligent technology for electrochemical analyses We don t have to explain the basics of electrochemical

More information

testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode Draft Version

testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode Draft Version testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode Draft Version ph C The new ph measuring instruments with innovative probe engineering

More information

ph measurement Content

ph measurement Content ph measurement Content 53 Applications and meters overview 54 ph benchtop meters 54 inolab Multi IDS - digital 55 inolab ph - analogue 58 Portable ph meters 58 MultiLine IDS - digital 59 ProfiLine - analogue

More information

WATER ANALYSIS The ph Value. The Redox Potential. ALMEMO ph and Redox Measurement. The Electrical Conductivity

WATER ANALYSIS The ph Value. The Redox Potential. ALMEMO ph and Redox Measurement. The Electrical Conductivity www.ahlborn.com WATER ANALYSIS The ph Value The ph value is a logarithmic measure for the concentration of the H ions in a hydrous solution and indicates, by a numerical value, whether the solution has

More information

Concise laboratory catalogue

Concise laboratory catalogue 2008 Concise laboratory catalogue Portable and bench-top instruments for ph, EC, ISE, DO and C measurements. Simple and advanced models covering from routine measurements to maximum requirements in investigation.

More information

ph/redox Measurement CPM 280

ph/redox Measurement CPM 280 Technical Information TI 346C/07/en/07.03 51511752 ph/redox Measurement CPM 280 Battery-driven pocket meter for ph and redox measurement Application CPM 280 is a compact pocket meter for measuring ph value

More information

BENCH TOP INSTRUMENTS DELTA OHM

BENCH TOP INSTRUMENTS DELTA OHM CRN TECNOPART, S.A. Sant Roc 30 08340 VILASSAR DE MAR (Barcelona) Tel 902 404 748-937 591 484 Fax 937 591 547 e-mail:crn@crntp.com http:// www.crntecnopart.com DO-060.92E BENCH TOP INSTRUMENTS DELTA OHM

More information

The ph Value The ph value is a logarithmic measure for the concentration of the H ions in a hydrous solution and indicates, by a numerical value, whet

The ph Value The ph value is a logarithmic measure for the concentration of the H ions in a hydrous solution and indicates, by a numerical value, whet Content ph value, redox potential, conductivity 15.02 The Electrical Conductivity 15.03 Solute oxygen in liquids 15.03 ph one-bar measuring chains FY 96 PHEK, FY 96 PHER, FY 96 PHEN 15.04 ph insertion

More information

Starter Starter Electrodes

Starter Starter Electrodes Starter Starter Electrodes High Performance Water Analysis Instruments Ingeniously Practical Starter Electrodes Selector Guide Standard Aqueous samples, general purpose (e.g. ph buffers) Waste water River/lake

More information

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature ph/o.r.p. probe For many different types of installations and applications Large selection of probe for a wide range of holder Useable for pipe DN15 to DN200 Type 8203 can be combined with... Type 8200

More information

Digital Dissolved Oxygen, Conductivity, TDS and ph Meter

Digital Dissolved Oxygen, Conductivity, TDS and ph Meter User's Guide Digital Dissolved Oxygen, Conductivity, TDS and ph Meter Model DO700 Introduction Congratulations on your purchase of the Extech DO700 meter. For best results, please read the entire manual

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Model IQ120 and IQ125 Professional ph Meter with Silicon Chip Sensor (IQ125 additional instructions printed in RED) IQ Scientific Instruments 2075-E Corte del Nogal Carlsbad, CA

More information

water proof water proof Tap water, pure water application Precious, trace amount sample 3-in-1 Plastic Electrode D

water proof water proof Tap water, pure water application Precious, trace amount sample 3-in-1 Plastic Electrode D ELECTRODE LINE UP electrode just got Touer! Enhanced durability of the glass membrane makes it four times stronger than the conventional Tou electrode. Response glass NEW The patented silver ion trap technology

More information

ph / Temperature Meter for Cheese with Application Specific Probe

ph / Temperature Meter for Cheese with Application Specific Probe C/ F ph / Temperature Meter for Cheese with Application Specific Probe ph Application Importance ph is an essential measurement throughout the entire cheesemaking process. From the initial measurements

More information

DOC /2013, Edition 1. User Manual

DOC /2013, Edition 1. User Manual DOC022.52.80407 50 49 08/2013, Edition 1 User Manual Table of Contents Specifications...3 General information...3 Safety information...3 Use of hazard information...3 Precautionary labels...4 Product

More information

HD HD HD HD HD

HD HD HD HD HD HD2205.2 - HD2206.2 - HD2256.2 - HD2259.2 - HD22569.2 Introduction The instrument series HD2205.2, HD2206.2, HD2256.2, HD2259.2, and HD2569.2 is made up of bench top instruments for electrochemical measures:

More information

Metso Concentration Measurement 3300

Metso Concentration Measurement 3300 Metso Concentration Measurement 3300 Metso Concentration 3300 Accurate direct in-line measurement The Concentration Measurement is provided with intelligent technology calculating the concentration of

More information

WATER QUALITY ANALYZERS SENSOR TECHNOLOGY. Customer Registration System. Dimesional Outlines Unit: mm(in) ORP ION. Conductivity.

WATER QUALITY ANALYZERS SENSOR TECHNOLOGY. Customer Registration System. Dimesional Outlines Unit: mm(in) ORP ION. Conductivity. Dimesional Outlines Unit: mm(in) F-50 Series / DS-50 Series 374(14.7) D-50 Series / ES-51 / OM-51 179(7.0) 80(3.1) 40(1.6) 230(9.1) 339(13.3) 170(6.7) CE marking compliant 68(2.7) 30 (1.2) Customer Registration

More information

ph Meters ph Value The water molecule has the property of dissociating into two ionic components in aqueous solutions.

ph Meters ph Value The water molecule has the property of dissociating into two ionic components in aqueous solutions. ph Meters ph Value The water molecule has the property of dissociating into two ionic components in aqueous solutions. H O H + + OH The H + ion is termed hydrogen ion or proton, the OH ion hydroxide ion.

More information

LCS Laboratory Inc. 700 Collip Circle, Unit 218, London ON, N6G 4X8, (519) ,

LCS Laboratory Inc. 700 Collip Circle, Unit 218, London ON, N6G 4X8, (519) , LCS Laboratory Inc. 700 Collip Circle, Unit 218, London ON, N6G 4X8, (519) 777-5232, info@labconserv.com www.labconserv.com What is Acidity and Alkalinity? What does ph mean? How do we measure ph? How

More information

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

PHS-25CW/3BW Benchtop ph Meter Instruction Manual PHS-25CW/3BW Benchtop ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD PHS-W Series Benchtop ph Meter 1 Introduction Thank you for selecting the PHS-W series benchtop ph meter. This manual provides

More information

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD PHS-25CW/3BW Benchtop ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD PHS-W Series Benchtop ph Meter 1 Introduction Thank you for selecting the PHS-W series benchtop ph meter. This manual provides

More information

HD HD HD HD HD

HD HD HD HD HD HD2205.2 - HD2206.2 - HD2256.2 - HD2259.2 - HD22569.2 Introduction The instrument series HD2205.2, HD2206.2, HD2256.2, HD2259.2, and HD2569.2 is made up of bench top instruments for electrochemical measures:

More information

ph Meters & Electrodes

ph Meters & Electrodes ph Meters ph Meters & Electrodes Quick and Reliable ph Results For Results at Your Fingertips 184 Page Overview 186 187 SevenMulti 188 189 SevenCompact 190 191 SevenGo and SevenGo Duo 192 195 FiveEasy

More information

MULTIFUNCTION COMPUTER METER CX-742 USERS MANUAL

MULTIFUNCTION COMPUTER METER CX-742 USERS MANUAL MULTIFUNCTION COMPUTER METER CX-742 USERS MANUAL CONTENTS 1. BASIC INFORMATION 3 2. USING THE INFORMATION 4 3. THE PROFILE OF THE METER 5 4. TECHNICAL DATA 7 5. SCREENS 8 6. USING THE KEYBOARD 10 7. THE

More information

PC100 Handheld ph/cond./tds/sal. Meter. Instruction Manual

PC100 Handheld ph/cond./tds/sal. Meter. Instruction Manual PC100 Handheld ph/cond./tds/sal. Meter Instruction Manual Table of Contents 1. Introduction ------------------------------------------------------------------------------------------------------------------------

More information

symphony Multisensor Probes

symphony Multisensor Probes DOC022.53.80319 symphony Multisensor Probes 07/2012, Edition 1 User Manual Table of contents Safety information on page 3 Calibration on page 6 Specifications on page 3 Sample requirements on page 8 Product

More information

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Oxidising agents such as chlorine or anorganic

More information

ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

ph Electrode basics ph Electrodes  Model 19 B /1 =1 m 24 B /1 =1 m s ph electrodes are constructed from a special composition which senses the hydrogen ion concentration. This is typically composed of alkali metal ions. The alkali metal ions of the and the hydrogen ions

More information

ph electrodes with screw cap S7. Special application electrodes.

ph electrodes with screw cap S7. Special application electrodes. ph electrodes with screw cap. Special application electrodes. Suitable to cover special applications. 52 07 Flat membrane One drop of distilled water is sufficient to take a measurement 52 08 and 52 09

More information

ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20

ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20 ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20 For comprehensive documentation and monitoring of temperature, pressure and humidity in

More information

testo 230 ph- and temperature measuring instrument Instruction manual

testo 230 ph- and temperature measuring instrument Instruction manual testo 230 ph- and temperature measuring instrument Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 5 2.1. About this document... 5 2.2. Ensure safety... 5 2.3.

More information

INE-DDB-303A Portable Conductivity Meter Instruction Manual

INE-DDB-303A Portable Conductivity Meter Instruction Manual INE-DDB-303A Portable Conductivity Meter Instruction Manual Operation ManualPLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com,3

More information

Bante210 Benchtop ph Meter Instruction Manual

Bante210 Benchtop ph Meter Instruction Manual Bante210 Benchtop ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante210 Benchtop ph Meter 1 Introduction Thank you for selecting the Bante210 benchtop ph meter. This manual provides a step-by-step

More information

P S H - S 3G m t e e t r e (C ( E mar ar e k d e ) P B H - B 4 - Por or ab ab e l PH M t e e t r

P S H - S 3G m t e e t r e (C ( E mar ar e k d e ) P B H - B 4 - Por or ab ab e l PH M t e e t r PHS-3G PH meter (CE marked) Function: 1.large screen, LCD display, dual parameter 2.Automatic buffer recognition and two-point calibration 3. It has the function of manual temperature 4.The instrument

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

Ion-selective Measurements

Ion-selective Measurements Ion-selective Measurements Ion-selective measurement is a method for determining the concentration of dissolved ions. Potassium ions, sodium ions, fluoride or chloride are examples of such cations and

More information

NeoMet. Instruction Manual. istek, Inc. Portable ph/ise/mv/orp, DO/O2/Air, Conductivity/TDS/Salinity/Temp Meter 29D 47C 415CP 815PDC

NeoMet. Instruction Manual. istek, Inc. Portable ph/ise/mv/orp, DO/O2/Air, Conductivity/TDS/Salinity/Temp Meter 29D 47C 415CP 815PDC NeoMet Portable ph/ise/mv/orp, DO/O2/Air, Conductivity/TDS/Salinity/Temp Meter Model 79P 29D 47C 415CP 815PDC Instruction Manual istek, Inc. TABLE OF CONTENTS CHAPTER I. INTRODUCTION...4 ph/ise/mv/orp/temp

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide

More information

Bante900P Portable Multiparameter Water Quality Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Bante900P Portable Multiparameter Water Quality Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD Bante900P Portable Multiparameter Water Quality Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante900P Portable Multiparameter Water Quality Meter 1 Introduction Thank you for selecting the Bante900P

More information

Application Your benefits

Application Your benefits Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 flow assembly Application Oxidizing agents such as chlorine or anorganic

More information

Benchtop Water Quality Meters 1000 Series

Benchtop Water Quality Meters 1000 Series ph ORP Ion Conductivity Resistivity Total Dissolved Solids Salinity Benchtop Water Quality Meters 1000 Series METERS 2 YEAR W A R R A N T Y M A D E I N J A P A N www.horiba-laqua.com Benchtop Water Quality

More information

PH700 Benchtop ph Meter Instruction Manual

PH700 Benchtop ph Meter Instruction Manual PH700 Benchtop ph Meter Instruction Manual APERA INSTRUMENTS, LLC www.aperainst.com Manual Version 3.1 Table of Contents 1 Brief Introduction... - 1-1.1 Main Features... - 1-2 Technical Specifications...

More information

OEM ph Competences. Solutions for ph OEM Applications in Liquid Analysis

OEM ph Competences. Solutions for ph OEM Applications in Liquid Analysis OEM ph Competences Solutions for ph OEM Applications in Liquid Analysis ph Glass Electrodes The method of ph measurement using glass electrodes is a potentiometric measurement method. Since glass is basically

More information

INE-PHS-3E ph Meter Operating Manual

INE-PHS-3E ph Meter Operating Manual INE-PHS-3E ph Meter Operating Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.12.16 ADVICE: Read this instruction

More information

Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A

Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A imagine explore learn Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A Overview Ammonium ions (NH 4+ ) can be found in fertilizer, cleaning products, processed meats and in the waste of

More information

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements www.milwaukeeinst.com INSTRUCTION MANUAL www.milwaukeeinst.com 1 Instruction Manual MA886 Refractometer for Sodium Chloride

More information

Guide to ph Analysis.

Guide to ph Analysis. Guide to ph Analysis. XX Why Contents ph Matters Table of Contents Why ph Matters pg 4 What You Need pg 6 How to Measure pg 14 Slope and offset pg 18 Checklist pg 20 Best Practices pg 21 2 Guide to ph

More information

NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC

NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC OPERATING MANUAL ba15362e03 10/2014 NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC NITRATE SENSITIVE ELECTRODE NO 500 NO 800 Note The latest version of the present operating manual can be found on the Internet

More information

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology Clean Water through Innovative Technology NEW!! Instrument Overview Reliable Chlorine Monitoring HF scientific developed the OnLine Residual Chlorine Monitor specifically for drinking water, wastewater

More information

Photometer AL250. Scroll Memory (SM) N.I.S.T Traceability. Highlights

Photometer AL250. Scroll Memory (SM) N.I.S.T Traceability. Highlights Photometer AL250 10 The AL250 models each offer one test method, while the AL250+ units are programmed for a number of different parameters. The units supply accurate, reproducible results very quickly.

More information

Thermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement

Thermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement We measure it. Thermal anemometer testo 405 Flow velocity measuring instrument with temperature measurement Volume flow measurement up to 99,990 m³/h Extendable telescope up to 300 mm m/s C Display illumination

More information

ISEmax CAS40D. Technical Information

ISEmax CAS40D. Technical Information Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor

More information

Process Instrumentation analyzers

Process Instrumentation analyzers PCA300 Family Chlorine, ph, ORP and Temperature Analyzers Backlit LCD display Nema 4X protection.10 DPD chlorine measurement method Colorimeter diagnostics Reagent reminder Amplified ph/temperature probe

More information

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051 imagine explore learn Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051 Overview Sodium is highly abundant in the lithosphere (Earth s outer shell) where it occurs as rock salt deposits as

More information

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF Translated English of Chinese Standard: GB31604.11-2016 www.chinesestandard.net Buy True-PDF Auto-delivery. Sales@ChineseStandard.net NATIONAL STANDARD OF GB THE PEOPLE S REPUBLIC OF CHINA GB 31604.11-2016

More information

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL HI96821 Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully before using this

More information

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities instruments 5 YEARS G U A R A N T E E Quality at a reasonable price The optimum combination

More information

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode. ph sensor with electrode ENPH-A016 ph sensor with flat electrode ENPH-F052 The ph sensor replaces the traditional ph meter adding powerful capabilities such as collecting the ph data and displaying the

More information

Oligo Click S ROTI kit for DNA labeling

Oligo Click S ROTI kit for DNA labeling USER MANUAL Oligo Click S ROTI kit for DNA labeling ROTI kit for DNA labeling Carl Roth GmbH + Co. KG Oligo Click S ROTI kit for DNA labeling For Click Chemistry labeling of up to 10 nmol oligonucleotide

More information

Oligo Click M Reload ROTI kit for DNA labeling

Oligo Click M Reload ROTI kit for DNA labeling USER MANUAL Oligo Click M Reload ROTI kit for DNA labeling ROTI kit for DNA labeling Carl Roth GmbH + Co. KG Oligo Click M Reload ROTI kit for DNA labeling For Click Chemistry labeling of up to 100 nmol

More information

Chloromax CCS142D. Technical Information

Chloromax CCS142D. Technical Information Technical Information Chloromax CCS142D Digital sensor with Memosens technology for determining free chlorine Membrane-covered amperometric sensor for process and drinking water applications Application

More information

Fluoride Sealed Electrode Sensor Bundle Product Number: ENFLU049

Fluoride Sealed Electrode Sensor Bundle Product Number: ENFLU049 imagine explore learn Fluoride Sealed Electrode Sensor Bundle Product Number: ENFLU049 Overview Fluoride is often added to drinking water and to toothpaste to prevent dental decay. In high concentrations,

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

Thermometers. Applications

Thermometers. Applications 92 Temperature Thermometers Thermometers On the next pages you will find a broad range of thermometers with fixed probes or exchangeable probes with rigid probes or probes with cable and hand grip. The

More information

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides. The Drop Counter sensor is an optical sensor that accurately records the number of drops of titrant added during a titration. The Drop Counter sensor software can automatically convert the number of drops

More information

Instruction Manual HI Refractometer for Sodium Chloride Measurements

Instruction Manual HI Refractometer for Sodium Chloride Measurements Instruction Manual HI 96821 Refractometer for Sodium Chloride Measurements www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully

More information

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements www.milwaukeeinst.com INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements www.milwaukeeinst.com 1 Instruction Manual MA881 Refractometer for Invert Sugar Measurements

More information

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com INSTRUCTION MANUAL Milwaukee Refractometer MA887 Refractometer for Seawater Measurements 1 Instruction

More information

WATER QUALITY ANALYZERS SENSOR TECHNOLOGY ORP ION. Conductivity. Temperature. Resistivity SALT

WATER QUALITY ANALYZERS SENSOR TECHNOLOGY ORP ION. Conductivity. Temperature. Resistivity SALT WATER QUALITY ANALYZERS ORP SENSOR TECHNOLOGY Conductivity DO Temperature Resistivity WaterQuality(E)出力用 10.6.24 9:12 PM ページ1 ELECTRODE LINE UP NEW Sleeve 6367-10D Precious, trace amount sample 3-in-1

More information

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter Water and Lab Products, Thermo Fisher Scientific Technical Note 505 Key Words Thermo Scientific Orion

More information

Laboratory Products. The first address for Precision measurement

Laboratory Products. The first address for Precision measurement Laboratory Products The first address for Precision measurement Welcome to SCHOTT Instruments With this new catalogue we are presenting you our complete laboratory products: The catalogue covers the product

More information

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Oxidising agents such as chlorine or anorganic

More information

NH 3 -selective electrodes

NH 3 -selective electrodes NH 3 -selective electrodes Manual 8.109.8031EN Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com NH 3 -selective electrodes Manual 8.109.8031EN

More information

White Paper. Perform Conductivity Measurements In Compliance with USP <645>

White Paper. Perform Conductivity Measurements In Compliance with USP <645> Perform Conductivity Measurements In Compliance with USP Water is the most widely used substance, raw material, or ingredient in the production, processing and formulation of compendial articles.

More information

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable Compact Titration Compact Titrator G20 One Click Titration Simple & Dependable Simplicity The Intelligent Helper for Simple Titrations One Click Titration Intuitive method adaptation Accurate results simply

More information

Electrochemistry. Conductivity of strong and weak electrolytes LEC 06. What you need: What you can learn about. Principle and tasks

Electrochemistry. Conductivity of strong and weak electrolytes LEC 06. What you need: What you can learn about. Principle and tasks LEC 06 Electrochemistry What you can learn about Kohlrausch s law Equivalent conductivity Temperature-dependence of conductivity Ostwald s dilution law Principle and tasks It is possible to differentiate

More information

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about Electrochemistry LEC 06 What you can learn about Galvanic cell Types of electrodes Nernst equation Potentiometry Principle and tasks The cell voltage and the Galvani voltage of the electrodes of an galvanic

More information

Acid Deposition and Oxidant Research Center (ADORC)

Acid Deposition and Oxidant Research Center (ADORC) Standard Operating Procedures for H measurement Acid Deposition and Oxidant Research Center (ADORC) Introduction - What is SOPs? - Objectives of SOPs - Major Items to be included in the SOPs in wet deposition

More information

Electricity. Electrolysis. Current and the transport of charge DETERMINATION OF THE FARADAY CONSTANT BASIC PRINCIPLES

Electricity. Electrolysis. Current and the transport of charge DETERMINATION OF THE FARADAY CONSTANT BASIC PRINCIPLES Electricity Current and the transport of charge Electrolysis DETERMINATION OF THE FARADAY CONSTANT Production of hydrogen by means of electrolysis and determining the volume of the hydrogen V. Determining

More information

Rapid RH Portable ph Meter. User's Manual

Rapid RH Portable ph Meter. User's Manual Rapid RH Portable ph Meter User's Manual This page intentionally left blank. 2 Contents 1. Introduction... 4 2. Included with the Rapid RH Portable ph Meter... 4 3. Understanding ph... 5 4. Calibrating

More information

symphony Reference Electrodes

symphony Reference Electrodes DOC022.53.80322 symphony Reference Electrodes 07/2012, Edition 1 User Manual Table of contents Safety information on page 3 Preparation for use on page 4 Specifications on page 3 Measurement on page 5

More information

Application Bulletin

Application Bulletin No. 292e Application Bulletin Of interest to: Plating industry, semiconductor industry, automotive industry, aeronautic industry, electroless nickel plating, hypophosphite, alkalinity P 9, 10 Determination

More information

STANDARD OPERATING PROCEDURE

STANDARD OPERATING PROCEDURE Ref.. Table of Contents Page. Scope 2 2. Objective 2 3. Definitions 2 4. Responsibility 3 5. Procedure 3 5.. Diagram of Display and Control Panel 3 5.2. Installation 4 5.3. Operation 4 5.4. Calibration

More information

Differential ph Probe Type 18

Differential ph Probe Type 18 Differential ph Probe Type 18 Contents 1 Introduction 1.1 Glass testing 2 Measuring principle 2.1 Model applications 3 Technical data 4 Handling information for the glasslined ph probe 5 Storage and installation

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion

More information

10 samples per second

10 samples per second The Conductivity sensor is designed to measure conductivity of liquids and solutions capable of measuring the entire range of 0-20 millisiemens (ms). Conductivity is one of the most basic tests conducted

More information

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction User s Guide Waterproof Palm ph Meter Model PH220 Introduction Congratulations on your purchase of the Extech PH220 waterproof ph/mv meter. This microprocessor-based device with tactile buttons is battery

More information

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements www.milwaukeeinst.com INSTRUCTION MANUAL www.milwaukeeinst.com 1 Instruction Manual MA888 Refractometer for Ethylene Glycol

More information

HI HI 8633 HI HI 8734 HI

HI HI 8633 HI HI 8734 HI 1 Instruction Manual HI 8033 - HI 8633 HI 8733 - HI 8734 HI 933000 Portable Multi-Range Conductivity/TDS Meters Dear Customer, Thank you for choosing a Hanna Product. Please read this instruction manual

More information

The first address for Titration. TITRONIC 300 and TitroLine 5000

The first address for Titration. TITRONIC 300 and TitroLine 5000 The first address for Titration TITRONIC 300 and TitroLine 5000 Selection table titration piston burettes TITRONIC and automatic titrators TitroLine The most important features of titrators TitroLine and

More information

Automatic titrators, TitroMatic

Automatic titrators, TitroMatic 112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator

More information

WATER ACTIVITY MEASUREMENT WATER ACTIVITY

WATER ACTIVITY MEASUREMENT WATER ACTIVITY MEASUREMENT WATER ACTIVITY FAST AND PRECISE WATER ACTIVITY MEASUREMENTS. INTRODUCING AIRCHIP DIGITAL TECHNOLOGY. Determine product quality with ROTRONIC Aw products ROTRONIC Aw devices for laboratory and

More information

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Nitrate DOC316.53.01066 Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific

More information

INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements www.milwaukeeinst.com INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements www.milwaukeeinst.com 1 Instruction Manual MA872 Refractometer for Fructose Measurements TABLE

More information

Non contact temperature measurement

Non contact temperature measurement Non contact temperature measurement.applications. - Asphalt - Chemistry, adhesives - Electric / electronics - Glass - Rubber - Heating techniques - Wood - Air conditioning technology - Ceramics - Plastics

More information

PC Control / Touch Control

PC Control / Touch Control PC Control / Touch Control Version 6.0 / 5.840.0150 New Features Manual 8.840.8007EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com

More information

Titration of a strong acid with a strong base with Cobra4

Titration of a strong acid with a strong base with Cobra4 Titration of a strong acid with a strong base with Cobra4 TEC Related topics Strong and weak acids and bases, ph value, titration curves, equivalence point, potentiometry. Principle Hydrochloric acid is

More information