The challenges of field sensors for trace metal detection. Chris Searle Product Manager Trace2o Ltd

Size: px
Start display at page:

Download "The challenges of field sensors for trace metal detection. Chris Searle Product Manager Trace2o Ltd"

Transcription

1 The challenges of field sensors for trace metal detection Chris Searle Product Manager Trace2o Ltd

2 What is a heavy metal and why is it necessary to determine concentration? Tends to be categorised as Metallic elements with either; high atomic number, high atomic weight or high density Many are toxic even at very low concentrations, for example; arsenic, cadmium, mercury, chromium, thallium, lead Heavy metals bio-accumulate in the food chain plants, fish, aquatic life, animals Accumulation in the body causes serious health problems

3 Human Health Some of the symptoms and diseases caused by heavy metal poisoning. Irritability Inflammation Thyroid Problem Mental Confusion Depression Parkinson MS Alzheimer Headaches Fatigue Diabetes Prostate Problem The monitoring and clean-up of metal pollution is thus very important.

4 Sources of HM Contamination Mining Smelting Military activities Effluent discharge

5 How are Heavy Metals traditionally analysed? Laboratory methods AAS ICP-MS ICP-OES Expensive instruments Outsource? But long lab turnaround time Samples need to be collected, stabilised, transported

6 Flame AAS Cheaper instrument, but poor LODs As 150ppb, Hg 300ppb Single element technique Seconds for determination Approx 15-20k system cost Cannot be left unattended! Atomic Absorption

7 Graphite furnace AAS Better LODs but more expensive Approx 20-40k system cost Still a single element technique Minutes for determination Atomic Absorption

8 ICP-OES higher LODs than GFAA ICP-MS VERY low LOD Multi element technique Minutes for determination ICP-OES k system cost ICP-MS k system cost ICP-OES and ICP-MS

9 Portable techniques Photometry Ion-selective electrodes X-ray fluorescence DNA-based biosensors Stripping voltammetry

10 Photometry Limited range of parameters Complicated sample prep Affected by turbidity Very high LODs But low cost Reliable

11 Ion Selective Electrodes Limited range of parameters Expensive to replace Huge interference Unreliable But unaffected by turbidity

12 X-Ray Fluorescence Only for suspended fraction in aqueous samples Useless for dissolved components Expensive H&S concerns But easy, fast Non-destructive

13 DNA-based biosensors Limited range of parameters Limited detection ranges Expensive cost per test May require filtration But easy to use

14 Stripping voltammetry Proven technique (since 1922) Wide detection range Wide range of parameters Low LODs Low cost per test Little interference Turbidity not a problem

15 Principle of Operation Stripping Voltammetry (Anodic and Cathodic) Electrochemical Cell Comprises 3 Electrodes (Working, Ref, Cnt/Aux) Temperature Measurement High precision Stirrer Automatically applied potentials

16 Electrochemical Cell A V CE WE RE Working electrode (WE) is where the cell reaction takes place Reference Electrode (R) provides reference point for cell potential Counter Electrode (C) electrochemically inert, allows current to flow

17 Redox Potentials Utilise known redox potentials of metal ions to selectively reduce/oxidise analytes of interest. Measuring current during oxidation/reduction allows us to measure concentration. Zn Cd Pb Cu Potential

18 Anodic Stripping Voltammetry (ASV) A Deposition step Stripping step V WE WE CE WE RE Cd 2+ Cd 2+ Cd2+ Cd 2+ Cd 2+ Cd 2+ Cd 2+ + X + 2e - CdX Reduction CdX Cd 2+ + X +2e - Oxidation 1. A potential lower (more ve) than redox potential is applied to the cell, the analyte is reduced and deposited onto the electrode 2. The potential is then increased anodically, above the redox potential (more +ve), which oxidises the analyte and strips them from the electrode surface. 3. As analyte is oxidised, it gives off electrons and an increase in electrical current occurs. 4. The measured current provides a value which directly correlates to the concentration of metal in the solution.

19 Interpreting the data Plot of recorded data reveals a peak. The peak height is proportional to the concentration of ions in solution Voltammogram I V

20 Typical Voltammogram for Multiple standard additions of Cd & Pb Cd Pb

21 Working electrode selection Variety of possible working electrode options Hanging mercury drop electrode (HMDE) Solid metal electrode Carbon-based (glassy carbon, graphite) Modified electrodes

22 HMDE Hanging mercury drop electrode (HMDE) Static but renewable surface Popular for lab work Extremely reliable Unsuitable for field use Liquid mercury handling H&S concerns

23 Silver, gold, platinum Good for ASV, less useful for CSV Adsorbed hydrogen layers Surface oxides Require electrochemical cleaning Very expensive substrate Solid metal electrode

24 Many possibilities Pyrolytic graphite electrode (PGE), edge plane vs. basal plane Carbon paste electrode Carbon composite electrodes Glassy carbon electrode (GCE) Very low cost Carbon electrodes Soft surface easily renewable

25 Bare electrodes are not always ideal surfaces GCE can be modified with metal films Hg film, Au film, Bi film Can also be modified with nanomaterials Carbon nanotubes Gold nanoparticles Modified electrodes

26 Introduction to Metalyser Developed to provide low cost field analysis Traditionally Lab based Method Uses well established voltammetric technique Comparable with ICP and AAS Targeted at Natural water samples No pre-treatment required More complex samples can be analysed after pre-treatment Glassy carbon electrodes modified with Hg or Au film

27 The Metalyser uses the technique of Stripping Voltammetry and has 2 main components: - the Sonde - the Handheld unit Mounted within the Sonde» Electrodes» Temperature probe» Stirrer Metalyser: What & How? Mounted within the handheld unit» Potentiostat» Data Processor Response varies considerably with temperature, so must be measured Stirrer used partly to apply convective conditions, partly to ensure homogeneity of the solution. Applied potentials and stirrer motor automatically controlled

28 Advantages of Metalyser Low cost Analysis Linear data gives confidence Rapid results Portable field analyser Analysis possible without sample prep. No fume extraction required False results easily identifiable Turbid samples can be analysed Ease of use

29 Limitations of Metalyser Interference from Organics Interference from other metals Relatively limited range of metals compared with laboratory techniques

30 Factory Calibration? Response is linear but sensitivity will change for different sample types due to sample matrix effects (ph, conductivity, temperature) Electrode surface also affects sensitivity Thickness of the film Sensitivity reduces with number of samples and time. Can calibrate on one sample and test several consecutive samples from the same source Most accurate method is standard addition Effectively calibrated for every sample

31 HM1000 Portable Most popular instrument Automatic analysis Step-by-step instructions

32 HM2000 Deluxe 2 instruments voltammetric and photometric Increased concentration range from ppb to ppm Increased metal range (heavy metals and nonheavy metals)

33 HM3000 Field Pro Advancement on the HM1000 instrument with tablet PC 2 boxes (instrument and PC and reagent box) Lower detection limits due to ability to increase deposition times and perform linear regression on multiple data points. Sonde clamp included for laboratory-type analysis in the field

34 Field-based analysis of heavy metals in soils at mg/kg levels Fast, reliable results Innovative portable digestion apparatus HM4000 Metalyser - Soils Robust, dustproof, waterproof, IP67- rated Simple user-friendly reagent system Affordable alternative to ICP-AES and XRF techniques

35 Compact, lightweight benchtop trace metal analyser R&D usage Powerful bespoke control and analysis software Wireless connectivity Compact variable-volume electrochemical cell Integrated stirrer and temperature sensor Fully computer-controlled HM5000 Benchtop

36 HM5100 Benchtop Benchtop analyser with pre-installed tests Designed for routine analysis Remote control via Bluetooth (PC required) Complete with Windows control software Linear regression Capable of running EPA methods Could be used as a replacement AA instrument cheaper to buy, cheaper to install and cheaper to run.

37 UV Digester HMUV1825 Dual wavelength digester for rapid break down of organics, which improves the sensitivity and accuracy of the results Timer allows for increased efficiency in the lab allowing unattended digestion Available as benchtop or portable model

38 Questions?

Voltammetry. Voltammetry. An Introduction in Theory. Metrohm Ltd. CH-9100 Herisau Switzerland

Voltammetry. Voltammetry. An Introduction in Theory. Metrohm Ltd. CH-9100 Herisau Switzerland An Introduction in Theory Metrohm Ltd. CH-9100 Herisau Switzerland Overview What is? Electrode Types Voltammetric Techniques Measurement Modes Calibration Techniques Advantages of Summary = Volt-Am(pero)-Metry

More information

ANALYSIS OF LEAD IN SEAWATER

ANALYSIS OF LEAD IN SEAWATER ANALYSIS OF LEAD IN SEAWATER BY DIFFERENTIAL PULSE POLAROGRAPHY Introduction Electrochemical methods of analysis can be used for the quantitative analysis of any electroactive species any species that

More information

Prof. Dr. Biljana Škrbić, Jelena Živančev

Prof. Dr. Biljana Škrbić, Jelena Živančev 5 th CEFSER Training Course Analysis of chemical contaminants in food and the environment Faculty of Technology, University of Novi Sad, Novi Sad, Republic of Serbia 7-11 May 2012 Analysis of heavy elements

More information

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive Chapter 9: End-of-Chapter Solutions 1. The following comparison provides general trends, but both atomic absorption spectroscopy (AAS) and atomic absorption spectroscopy (AES) will have analyte-specific

More information

Voltammetry. Voltammetry and Polarograph. Chapter 23. Polarographic curves -- Voltammograms

Voltammetry. Voltammetry and Polarograph. Chapter 23. Polarographic curves -- Voltammograms Chapter 23 Voltammetry Voltammetry and Polarograph Electrochemistry techniques based on current (i) measurement as function of voltage (E appl ) Voltammetry Usually when the working electrode is solid,

More information

Determination of silver by differential pulse anodic stripping voltammetry: An APCELL experiment. 1

Determination of silver by differential pulse anodic stripping voltammetry: An APCELL experiment. 1 Determination of silver by differential pulse anodic stripping voltammetry: An APCELL experiment. 1 Magdalena Wajrak and Jacqueline Rummey School of Natural Sciences, Faculty of Computing, Health and Science,

More information

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy Evrim Kilicgedik Product Specialist, Atomic Spectroscopy Agilent Technologies 04.11.2011 2011 The Atomic Spectroscopy

More information

Product Descriptions and Offerings

Product Descriptions and Offerings Product Descriptions and Offerings Teledyne Leeman Labs is a leading innovator of analytical instrumentation for elemental analysis. Laboratories in industries ranging from environmental science, oil and

More information

Current based methods

Current based methods Current based methods Amperometric and voltammetric sensors More significant influence on analytical parameters (sensitivity, selectivity, interferences elimination) kind of method, potential range, electrode

More information

110 Lowell Rd Hudson, NH USA Tel:

110 Lowell Rd Hudson, NH USA Tel: 110 Lowell Rd Hudson, NH 03051 USA Tel: 603-886-8400 www.teledyneleemanlabs.com Product Descriptions and Offerings Teledyne Leeman Labs is a leading innovator of analytical instrumentation for elemental

More information

Air Quality 2 - Determination of Cd and Pb by Anodic Stripping Voltammetry

Air Quality 2 - Determination of Cd and Pb by Anodic Stripping Voltammetry Air Quality 2 - Determination of Cd and Pb by Anodic Stripping Voltammetry Introduction: In the first experiment of this set, you measured the concentration of benzene in gasoline, and it is a reasonable

More information

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer Innovative 0.01 0.1 1 10 Intuitive Concentration (ppb) R = 0.99999 Versatile Hydra II C Mercury Analyzer At Teledyne Leeman Labs; atomic spectroscopy is our business our only business. We are industry

More information

Basic Digestion Principles

Basic Digestion Principles Basic Digestion Principles 1 From Samples to Solutions Direct Analytical Method Solid Sample Problems: Mech. Sample Preparation (Grinding, Sieving, Weighing, Pressing, Polishing,...) Solid Sample Autosampler

More information

Specific Determination of Hydrogen Peroxide With A Catalase Biosensor Based on Mercury Thin Film Electrodes

Specific Determination of Hydrogen Peroxide With A Catalase Biosensor Based on Mercury Thin Film Electrodes Turk J Chem 24 (2000), 95 99 c TÜBİTAK Specific Determination of Hydrogen Peroxide With A Catalase Biosensor Based on Mercury Thin Film Electrodes Nil ERTAŞ Ege University, Faculty of Science, Department

More information

Heavy metal analysis of river water using the ItalSens HM1 sensor

Heavy metal analysis of river water using the ItalSens HM1 sensor Heavy metal analysis of river water using the ItalSens HM1 sensor Quantification of copper, lead and cadmium in aqueous solutions Last revision: December 15, 2015 2014 PalmSens BV www.palmsens.com Contents

More information

Atomic Absorption Spectrometer ZEEnit P series

Atomic Absorption Spectrometer ZEEnit P series Atomic Absorption Spectrometer ZEEnit P series Technical Data ZEEnit series Update 07/2014 OBue 1/ 5 ZEEnit P series Variable high-end AA Spectrometer with Deuterium and Zeeman Background Correction with

More information

Electronic Supplementary Material (ESI) for Chemical Communications This journal is The Royal Society of Chemistry 2011

Electronic Supplementary Material (ESI) for Chemical Communications This journal is The Royal Society of Chemistry 2011 Supplementary Information for Selective adsorption toward toxic metal ions results in selective response: electrochemical studies on polypyrrole/reduced graphene oxide nanocomposite Experimental Section

More information

Unit 2 B Voltammetry and Polarography

Unit 2 B Voltammetry and Polarography Unit 2 B Voltammetry and Polarography Voltammetric methods of Analysis What is Voltammetry? A time-dependent potential is applied to an electrochemical cell, and the current flowing through the cell is

More information

VALIDATION AND OPTIMIZATION OF AN IN-SITU COPPER-MODIFIED GLASSY CARBON ELECTRODE

VALIDATION AND OPTIMIZATION OF AN IN-SITU COPPER-MODIFIED GLASSY CARBON ELECTRODE ICAMS 2018 7 th International Conference on Advanced Materials and Systems VALIDATION AND OPTIMIZATION OF AN IN-SITU COPPER-MODIFIED GLASSY CARBON ELECTRODE KLODIAN XHANARI 1,2, ŽAN ŠAŠEK 1, BARBARA PETOVAR

More information

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF S2 PICOFOX Spectrometry Solutions Innovation with Integrity TXRF S2 PICOFOX True Trace Analysis with XRF for the First Time! You need to know the concentration of trace elements in environmental samples?

More information

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors Determination of major, minor and trace elements in rice flour using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Application note Food testing Authors John Cauduro Agilent Technologies,

More information

Analysis of Cadmium (Cd) in Plastic Using X-ray Fluorescence Spectroscopy

Analysis of Cadmium (Cd) in Plastic Using X-ray Fluorescence Spectroscopy Analysis of Cadmium (Cd) in Plastic Using X-ray Fluorescence Spectroscopy Hiroshi Onodera Application & Research Center, JEOL Ltd. Introduction um, PBB and PBDE) are subject to usage restrictions in Europe.

More information

Test Report No. CE/2017/40923 Date 2017/04/14 Page 2 of 5 Test Result(s) PART NAME No.1 COPPER COLORED METAL WIRE Test Item(s) Cadmium (Cd) Lead (Pb)

Test Report No. CE/2017/40923 Date 2017/04/14 Page 2 of 5 Test Result(s) PART NAME No.1 COPPER COLORED METAL WIRE Test Item(s) Cadmium (Cd) Lead (Pb) Test Report No. CE/2017/40923 Date 2017/04/14 Page 1 of 5 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Sample Receiving

More information

Supporting Information. Fluorescence Regulation of Copper Nanoclusters via DNA Template. Manipulation toward Design of a High Signal-to-Noise Ratio

Supporting Information. Fluorescence Regulation of Copper Nanoclusters via DNA Template. Manipulation toward Design of a High Signal-to-Noise Ratio Supporting Information Fluorescence Regulation of Copper Nanoclusters via DNA Template Manipulation toward Design of a High Signal-to-Noise Ratio Biosensor Junyao Li, Wenxin Fu, Jianchun Bao, Zhaoyin Wang*,

More information

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD BATTERY INDUSTRY STANDARD ANALYTICAL METHOD For the Determination of Mercury, Cadmium and Lead in Alkaline Manganese Cells Using AAS, ICP-AES and "Cold Vapour" European Portable Battery Association (EPBA)

More information

Electrochemical Techniques: Anodic Stripping Voltammetry

Electrochemical Techniques: Anodic Stripping Voltammetry Electrochemical Techniques: Anodic Stripping Voltammetry Quantitative Determination of Copper, Lead and Cadmium in Tap Water at a Thin Mercury Film Electrode. 1. Aim To use a standard additions method

More information

Thermo Scientific Electrochemistry Products

Thermo Scientific Electrochemistry Products Comparing Performance of DO Methods The world leader in serving science in Water and Seawaters Thermo Scientific Electrochemistry Products Dissolved Oxygen Measurement Oxygen is essential for most of the

More information

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer is powerful simultaneous full

More information

ТА LAB ANALYZER. voltammetric analyzers. Detected admixtures. Usability. Technical features. Characteristic features

ТА LAB ANALYZER. voltammetric analyzers. Detected admixtures. Usability. Technical features. Characteristic features voltammetric analyzers ТА LAB ANALYZER Automated device with three measurement channels and two sources of UV radiation of analyzed solutions. The principle of operation is stripping voltammetry with the

More information

UV Spectroscopy Determination of Aqueous Lead and Copper Ions in Water

UV Spectroscopy Determination of Aqueous Lead and Copper Ions in Water UV Spectroscopy Determination of Aqueous Lead and Copper Ions in Water C. H. Tan a, Y. C. Moo a, M. Z. Matjafri a and H. S. Lim a a School of Physics, Universiti Sains Malaysia, 118 Pulau Pinang, Malaysia.

More information

Determination of Zinc, Cadmium, Lead and Copper in Effluent Sample

Determination of Zinc, Cadmium, Lead and Copper in Effluent Sample Determination of Zinc, Cadmium, Lead and Copper in Effluent Sample Branch: General analytical chemistry, water, waste water, environmental protection Key Words 797 / polarography / VA / 8 / Zn / Cd / Pb

More information

Novel polymer-based nanocomposites for application in heavy metal pollution remediation. Emerging Researcher Symposium

Novel polymer-based nanocomposites for application in heavy metal pollution remediation. Emerging Researcher Symposium Novel polymer-based nanocomposites for application in heavy metal pollution remediation Emerging Researcher Symposium Lara Kotzé-Jacobs 10 October 2012 Introduction: SA s water problem SA is a water scarce

More information

NECi Nitrate Kits FAQs

NECi Nitrate Kits FAQs Why use enzymes? Enzymes are catalysts that drive complex biological reactions. They happen to be excellent reagents for analytical chemistry because they are reliable, accurate, sensitive, selective,

More information

ADI2045VA Process Analyzer

ADI2045VA Process Analyzer ADI2045VA Process Analyzer Trace Metal and Plating Bath Analysis Trace Metal and Plating Bath Analysis Metrohm Applikon On-Line Analyzers Metrohm Applikon B.V. has over 25 years of experience with on-line

More information

Geogenic versus Anthropogenic Metals and Metalloids

Geogenic versus Anthropogenic Metals and Metalloids Geogenic versus Anthropogenic Metals and Metalloids Geochemical methods for evaluating whether metals and metalloids are from geogenic versus anthropogenic sources 1 Definitions Geogenic from natural geological

More information

Fundamental molecular electrochemistry - potential sweep voltammetry

Fundamental molecular electrochemistry - potential sweep voltammetry Fundamental molecular electrochemistry - potential sweep voltammetry Potential (aka voltammetric) sweep methods are the most common electrochemical methods in use by chemists today They provide an efficient

More information

Lecture 4. Conductance sensors. ChemFET. Electrochemical Impedance Spectroscopy. py Practical consideration for electrochemical biosensors.

Lecture 4. Conductance sensors. ChemFET. Electrochemical Impedance Spectroscopy. py Practical consideration for electrochemical biosensors. Lecture 4 Conductance sensors. ChemFET. Electrochemical Impedance Spectroscopy. py Practical consideration for electrochemical biosensors. Conductivity I V = I R=, L - conductance L= κa/, l Λ= κ /[ C]

More information

novaa 800 D Atomic Absorption Spectrometer

novaa 800 D Atomic Absorption Spectrometer Technical Data Atomic Absorption Spectrometer Cpt : +27 (0) 21 905 0476 Jhb : +27 (0) 11 794 Dbn : +27 (0) 31 266 2454 1/7 General The is a compact atomic absorption spectrometer with deuterium background

More information

Definition 1 An element or compound is oxidized when it gains oxygen atoms

Definition 1 An element or compound is oxidized when it gains oxygen atoms Oxidation and Reduction Part I Learning Outcomes 1. Introduction to oxidation and reduction: simple examples only, e.g. Na with Cl 2, Mg with O 2, Zn with Cu 2+. 2. Oxidation and reduction in terms of

More information

XANTHINE OXIDASE MODIFIED GLASSY CARBON PASTE ELECTRODES

XANTHINE OXIDASE MODIFIED GLASSY CARBON PASTE ELECTRODES XANTHINE OXIDASE MODIFIED GLASSY CARBON PASTE ELECTRODES Ülkü Anık Kırgöz 1, Suna Timur 1, Joseph Wang 2, Azmi Telefoncu 1 Ege University/TURKIYE New Mexico State University, USA Carbon is an ideal electrode

More information

Chapter 24. Electrogravimetry and Coulometry

Chapter 24. Electrogravimetry and Coulometry Chapter 24 Electrogravimetry and Coulometry Dynamic Electrochemical Methods of analysis Electrolysis Electrogravimetric and Coulometric Methods For a cell to do any useful work or for an electrolysis to

More information

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction application Note Atomic Absorption Authors David Bass Senior Product Specialist Cynthia P. Bosnak Senior Product Specialist PerkinElmer, Inc. Shelton, CT 06484 USA The Determination of Toxic, Trace, and

More information

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219 REX Evaluation Guide American Micro Detection Systems Inc. 2800 March Lane, Suite 200 Stockton, CA 95219 I. INTRODUCTION REX (Real-time Elemental X-ray Fluorescence System) is the only instrument capable

More information

Overview of X-Ray Fluorescence Analysis

Overview of X-Ray Fluorescence Analysis Overview of X-Ray Fluorescence Analysis AMPTEK, INC., Bedford, MA 01730 Ph: +1 781 275 2242 Fax: +1 781 275 3470 sales@amptek.com 1 What is X-Ray Fluorescence (XRF)? A physical process: Emission of characteristic

More information

Solved Examples On Electrochemistry

Solved Examples On Electrochemistry Solved Examples On Electrochemistry Example 1. Find the charge in coulomb on 1 g-ion of Charge on one ion of N 3- = 3 1.6 10-19 coulomb Thus, charge on one g-ion of N 3- = 3 1.6 10-19 6.02 10 23 = 2.89

More information

Analysis of Soil and Sewage Sludge in the Field with a Portable ED-XRF Spectrometer

Analysis of Soil and Sewage Sludge in the Field with a Portable ED-XRF Spectrometer AN APPLICATION BRIEF FROM SPECTRO ANALYTICAL INSTRUMENTS When results matter Analysis of Soil and Sewage Sludge in the Field with a Portable ED-XRF Spectrometer Introduction Arsenic, barium, cadmium, chromium,

More information

HEAVY METALS AND LACTATE MONITORING SYSTEM

HEAVY METALS AND LACTATE MONITORING SYSTEM II WORKSHOP ON CHEMICAL SENSORS AND BIOSENSORS HEAVY METALS AND LACTATE MONITORING SYSTEM Manuela Adami 1, Giorgio Martinazzo 1, Simona Villari 1, Mario Panza 1, Marco Sartore 1, Claudio Nicolini 2 1 Parco

More information

Pros and Cons of Water Analysis Methods

Pros and Cons of Water Analysis Methods Water Lens, LLC 4265 San Felipe, Suite 1100 Houston, Texas 77027 Office: (844) 987-5367 www.waterlensusa.com Pros and Cons of Water Analysis Methods Prepared by: Adam Garland, CTO Water Lens, LLC ICP-MS/OES

More information

Low Level Detection of Priority Inorganic Pollutants in Water. Anthony Neumann, MSc Darren Crichton, BSc

Low Level Detection of Priority Inorganic Pollutants in Water. Anthony Neumann, MSc Darren Crichton, BSc Low Level Detection of Priority Inorganic Pollutants in Water Anthony Neumann, MSc Darren Crichton, BSc Priority List of Pollutants Consists of 16 metals and/or transitional elements. Enter the human food

More information

Subject: Fundamentals of Stripping Voltammetry

Subject: Fundamentals of Stripping Voltammetry Application Note S-6 Subject: Fundamentals of Stripping Voltammetry INTRODUCTION The demand for the detection and quantitation of trace components in complex samples has come form the public and private

More information

CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016

CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016 CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016 Name: INSTRUCTIONS: Read through the entire exam before you begin. Answer all of the questions. For questions involving calculations, show all of

More information

S2 PICOFOX. Innovation with Integrity. Benchtop TXRF Spectrometer TXRF

S2 PICOFOX. Innovation with Integrity. Benchtop TXRF Spectrometer TXRF S2 PICOFOX Benchtop TXRF Spectrometer Innovation with Integrity TXRF S2 PICOFOX - Fast Trace Element Analysis with XRF The S2 PICOFOX is the world s first portable benchtop spectrometer for fast quantitative

More information

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds Atmospheric Analysis Gases Sampling and analysis of gaseous compounds Introduction - External environment (ambient air) ; global warming, acid rain, introduction of pollutants, etc - Internal environment

More information

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS Application Note Food Testing Author John Cauduro Agilent Technologies, Australia Introduction Trace

More information

Graphite Block Acid Digestion System ODLAB

Graphite Block Acid Digestion System ODLAB Graphite Block Acid Digestion System Table of contents 1. company introduction and product development background 2. Hot Plate and Graphite Block Acid Digestion and Microwave Digestion comparison 1 2 3

More information

Hydrogen & Chlorine monitoring for the Chlor-Alkali Industry

Hydrogen & Chlorine monitoring for the Chlor-Alkali Industry technical datasheet Application Note - AN9041 Hydrogen & Chlorine monitoring for the Chlor-Alkali Industry Measurement Technology Limited (MTL) part of Eaton's Crouse-Hinds business, design and manufacture

More information

Electrochemical study and applications of the selective electrodeposition of silver on quantum dots

Electrochemical study and applications of the selective electrodeposition of silver on quantum dots SUPPORTING INFORMATION Electrochemical study and applications of the selective electrodeposition of silver on quantum dots Daniel Martín-Yerga*, Estefanía Costa Rama and Agustín Costa-García Department

More information

The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples The Hydra II Family of Mercury Analyzers At Teledyne Leeman Labs, atomic spectroscopy is our business our only business. We are industry leading innovators with a proven track record providing systems

More information

Elemental analysis by X-ray f luorescence. Sequential benchtop WDXRF spectrometer

Elemental analysis by X-ray f luorescence. Sequential benchtop WDXRF spectrometer Elemental analysis by X-ray f luorescence Sequential benchtop WDXRF spectrometer Elemental analysis is one of the most important fundamental measurements made for industrial quality control and research

More information

Process Instrumentation analyzers

Process Instrumentation analyzers PCA300 Family Chlorine, ph, ORP and Temperature Analyzers Backlit LCD display Nema 4X protection.10 DPD chlorine measurement method Colorimeter diagnostics Reagent reminder Amplified ph/temperature probe

More information

Intelligent Sensor Management for Brewing Processes

Intelligent Sensor Management for Brewing Processes Intelligent Sensor Management for Brewing Processes Intelligent Sensor Management Intelligent Sensor Management, or simply ISM, is a digital technology for in-line process analytical systems that enhances

More information

Preparation of Food and Feed Samples for Metals Analysis

Preparation of Food and Feed Samples for Metals Analysis White Paper Preparation of Food and Feed Samples for Metals Analysis Alan Cross Technical Specialist, Metals Laboratory Preparation of Food and Feed Samples for Metals Analysis The relative virtues of

More information

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste Experiment ISE: Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste 67 You have been hired by the government to check the fluoride concentration labelling on some major

More information

BSc Chemistry (honours)

BSc Chemistry (honours) Nanocomposite-graphene based platform for heavy metal detection Chandré Monique Willemse BSc Chemistry (honours) A thesis submitted in fulfillment of the requirements for the degree of Magister Scientiae

More information

N Goalby chemrevise.org

N Goalby chemrevise.org Redox Equilibria Electrochemical cells This type of cell can be called a Voltaic cell or Galvanic cell. Voltaic cells convert energy from spontaneous, exothermic chemical processes to electrical energy.

More information

Chapter 32. Electrolysis

Chapter 32. Electrolysis Chapter 32 Electrolysis 32.1 Electrolysis a type of redox reactions 32.2 Predicting preferential discharge of ions 32.3 Electrolysis of dilute sulphuric acid 32.4 Electrolysis of sodium chloride solution

More information

Reference electrode. Calomel electrode Hg in contact with Hg(I) chloride Ag/AgCl 15-2

Reference electrode. Calomel electrode Hg in contact with Hg(I) chloride Ag/AgCl 15-2 Potentiometry Potential measurements of electrochemical cells Ion selective methods Reference electrode Indicator electrode Potential measuring device Reference electrode Indicator electrodes Ion specific

More information

REMOVAL OF HEAVY METALS USING COMBINATION OF ADSORBENTS - A CASE STUDY USING INDUSTRIAL WASTE WATER

REMOVAL OF HEAVY METALS USING COMBINATION OF ADSORBENTS - A CASE STUDY USING INDUSTRIAL WASTE WATER REMOVAL OF HEAVY METALS USING COMBINATION OF ADSORBENTS - A CASE STUDY USING INDUSTRIAL WASTE WATER PROJECT REFERENCE NO. : 37S1399 COLLEGE : DAYANANDA SAGAR COLLEGE OF ENGINEERING, BANGALORE BRANCH :

More information

Test Method: CPSC-CH-E

Test Method: CPSC-CH-E UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 10901 DARNESTOWN RD GAITHERSBURG, MD 20878 Test Method: CPSC-CH-E1001-08 Standard Operating Procedure

More information

ELECTROCHEMISTRY. these are systems involving oxidation or reduction there are several types METALS IN CONTACT WITH SOLUTIONS OF THEIR IONS

ELECTROCHEMISTRY. these are systems involving oxidation or reduction there are several types METALS IN CONTACT WITH SOLUTIONS OF THEIR IONS Electrochemistry 1 ELECTROCHEMISTRY REDOX Reduction gain of electrons Cu 2+ (aq) + 2e > Cu(s) Oxidation removal of electrons Zn(s) > Zn 2+ (aq) + 2e HALF CELLS these are systems involving oxidation or

More information

2101 Atomic Spectroscopy

2101 Atomic Spectroscopy 2101 Atomic Spectroscopy Atomic identification Atomic spectroscopy refers to the absorption and emission of ultraviolet to visible light by atoms and monoatomic ions. It is best used to analyze metals.

More information

Cyclic Voltammetry. Fundamentals of cyclic voltammetry

Cyclic Voltammetry. Fundamentals of cyclic voltammetry Cyclic Voltammetry Cyclic voltammetry is often the first experiment performed in an electrochemical study of a compound, biological material, or an electrode surface. The effectiveness of cv results from

More information

Goals. The laboratory instructor has already purged the solutions of dissolved. Purging the from these solutions prevents spurious

Goals. The laboratory instructor has already purged the solutions of dissolved. Purging the from these solutions prevents spurious Goals 41 Cyclic Voltammetry XXGoals The goals of this experiment are to: Learn how to set up a screen-printed electrode Learn how to operate the Gamry potentiostat Determine the redox potential of potassium

More information

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows Silver DOC316.53.01134 Colorimetric Method Method 8120 0.02 to 0.70 mg/l Ag Powder Pillows Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows

More information

Electrochemistry. Electrochemical Process. The Galvanic Cell or Voltaic Cell

Electrochemistry. Electrochemical Process. The Galvanic Cell or Voltaic Cell Electrochemistry Electrochemical Process The conversion of chemical energy into electrical energy and the conversion of electrical energy into chemical energy are electrochemical process. Recall that an

More information

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

Quality Control Procedures for Graphite Furnace AAS using Avanta Software Application Note Quality Control Procedures for Graphite Furnace AAS using Avanta Software Introduction With the arrival of quality standards in the analytical laboratory, an ever increasing emphasis is

More information

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY 1.0 SCOPE AND APPLICATION 1.1 This digestion procedure is used for the preparation

More information

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon Atomic Absorption Spectrophotometry Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon Defination In analytical chemistry, Atomic absorption spectroscopy is a

More information

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials Thermo Scientific ICP-MS solutions for the semiconductor industry Maximize wafer yields with ultralow elemental detection in chemicals and materials Trace impurity analysis in chemicals an used in the

More information

Lesson on Electrolysis

Lesson on Electrolysis Lesson on Electrolysis This lesson package includes a lesson plan, a worksheet for students, and teachers notes on the worksheet. Activity Lesson 1 (50 min-2 Period lesson) Teacher explains (page 1 to

More information

Supporting Information

Supporting Information Supporting Information Trace Levels of Copper in Carbon Materials Show Significant Electrochemical CO 2 Reduction Activity Yanwei Lum,,,, Youngkook Kwon,,, Peter Lobaccaro,,,# Le Chen,, Ezra Lee Clark,,,#

More information

IGCSE Double Award Extended Coordinated Science

IGCSE Double Award Extended Coordinated Science IGCSE Double Award Extended Coordinated Science Chemistry 5 - Electricity and Chemistry Electrolysis You need to know that electrolysis is: - The breakdown of ionic substances into their constituent elements

More information

Solution Purging. Goals. 1. Purge both solutions with an inert gas (preferably N 2

Solution Purging. Goals. 1. Purge both solutions with an inert gas (preferably N 2 Goals 43 Cyclic Voltammetry XXGoals The goals of this experiment are to: Learn how to set up a screen-printed electrode Learn how to operate the Gamry potentiostat Determine the redox potential of potassium

More information

Class 12 Important Questions for Chemistry Electrochemistry

Class 12 Important Questions for Chemistry Electrochemistry Class 12 Important Questions for Chemistry Electrochemistry Multiple Choice Questions (Type-I) 1. Which cell will measure standard electrode potential of copper electrode? o (i) Pt (s) H2 (g,0.1 bar) H

More information

UV3000. Accurate, precise, and portable ambient gas point analyzer

UV3000. Accurate, precise, and portable ambient gas point analyzer UV3000 Accurate, precise, and portable ambient gas point analyzer The Cerex UV3000 is a multifunction analyzer designed to detect part per billion (ppb) to percent level concentrations of multiple gases

More information

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 236 ABSTRACT TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER Hagen Stosnach Röntec GmbH,

More information

Contents. Publisher s Foreword. Glossary of Symbols and Abbreviations

Contents. Publisher s Foreword. Glossary of Symbols and Abbreviations Publisher s Foreword Glossary of Symbols and Abbreviations v xiii 1 Equilibrium Electrochemistry and the Nernst Equation 1 1.1 Cell Thermodynamics....................... 1 1.2 The Nernst Equation........................

More information

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES Application note Geochemistry, metals, mining Authors John Cauduro Agilent Technologies, Mulgrave, Australia Introduction

More information

Chemistry 213. Electrochemistry I

Chemistry 213. Electrochemistry I 1 Chemistry 213 Electrochemistry I Electrochemical Cells Objective Oxidation/reduction reactions find their most important use in the construction of voltaic cells (chemical batteries). In this experiment,

More information

Chapter 20 Electrochemistry

Chapter 20 Electrochemistry Chapter 20 Electrochemistry Learning goals and key skills: Identify oxidation, reduction, oxidizing agent, and reducing agent in a chemical equation Complete and balance redox equations using the method

More information

Chemistry Instrumental Analysis Lecture 18. Chem 4631

Chemistry Instrumental Analysis Lecture 18. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 18 Oxidation/Reduction Reactions Transfer of electrons in solution from one reactant to another. Ce +4 + Fe +2 Ce +3 + Fe +3 Ce +4 and Fe 3+ Fe 2+ and Ce 3+

More information

Electrochemical cells. Section 21.1

Electrochemical cells. Section 21.1 Electrochemical cells Section 21.1 Electrochemical processes Chemical process either release energy or absorb energy This does not have to be solely heat or light - sometimes it can be in the form of electricity

More information

Research Article Anodic Stripping Voltammetry of Se 4+ on Gold-Modified Boron-Doped Diamond Electrodes

Research Article Anodic Stripping Voltammetry of Se 4+ on Gold-Modified Boron-Doped Diamond Electrodes International Electrochemistry Volume 212, Article ID 75878, 5 pages doi:1.1155/212/75878 Research Article Anodic Stripping Voltammetry of Se 4+ on Gold-Modified Boron-Doped Diamond Electrodes Stéphane

More information

DRAFT EAST AFRICAN STANDARD

DRAFT EAST AFRICAN STANDARD ICS 71.100.70 DRAFT EAST AFRICAN STANDARD Oils for cosmetic industry Methods of test Part 16 : Determination of Heavy metal Content EAST AFRICAN COMMUNITY EAS 2015 First Edition 2015 Copyright notice

More information

Study on Aqueous CO 2 Detection to Monitor the Potential Leakage of CO 2 Stored in the Ocean

Study on Aqueous CO 2 Detection to Monitor the Potential Leakage of CO 2 Stored in the Ocean tudy on Aqueous CO 2 Detection to Monitor the Potential Leakage of CO 2 tored in the Ocean ATO iroshi : Ph. D., P. E. Jp (Applied cience), Advanced Applied cience Department, Research Laboratory, Corporate

More information

Dry Cell: a galvanic cell with the electrolyte contained in a paste thickened by starch. anode and an inert graphite cathode.

Dry Cell: a galvanic cell with the electrolyte contained in a paste thickened by starch. anode and an inert graphite cathode. 1 BATTERIES Text Pages: 764-766, 787,788 Battery: a set of galvanic cells connected in series - The negative electrode of one cell is connected to the positive electrode of the next cell - The total voltage

More information

LAB REPORT ON XRF OF POTTERY SAMPLES By BIJOY KRISHNA HALDER Mohammad Arif Ishtiaque Shuvo Jie Hong

LAB REPORT ON XRF OF POTTERY SAMPLES By BIJOY KRISHNA HALDER Mohammad Arif Ishtiaque Shuvo Jie Hong LAB REPORT ON XRF OF POTTERY SAMPLES By BIJOY KRISHNA HALDER Mohammad Arif Ishtiaque Shuvo Jie Hong Introduction: X-ray fluorescence (XRF) spectrometer is an x-ray instrument used for routine, relatively

More information

CHEM N-12 November In the electrolytic production of Al, what mass of Al can be deposited in 2.00 hours by a current of 1.8 A?

CHEM N-12 November In the electrolytic production of Al, what mass of Al can be deposited in 2.00 hours by a current of 1.8 A? CHEM161 014-N-1 November 014 In the electrolytic production of Al, what mass of Al can be deposited in.00 hours by a current of 1.8 A? What products would you expect at the anode and the cathode on electrolysis

More information

Chapter 3 Electrochemical methods of Analysis-Potentiometry

Chapter 3 Electrochemical methods of Analysis-Potentiometry Chapter 3 Electrochemical methods of Analysis-Potentiometry Electroanalytical chemistry Contents Introduction Galvanic and electrolytic cells Salt bridge Electrode potential and cell potential Indicator

More information

1.11 Redox Equilibria

1.11 Redox Equilibria 1.11 Redox Equilibria Electrochemical cells Electron flow A cell has two half cells. The two half cells have to be connected with a salt bridge. Simple half cells will consist of a metal (acts an electrode)

More information