ТА LAB ANALYZER. voltammetric analyzers. Detected admixtures. Usability. Technical features. Characteristic features

Size: px
Start display at page:

Download "ТА LAB ANALYZER. voltammetric analyzers. Detected admixtures. Usability. Technical features. Characteristic features"

Transcription

1

2 voltammetric analyzers ТА LAB ANALYZER Automated device with three measurement channels and two sources of UV radiation of analyzed solutions. The principle of operation is stripping voltammetry with the use of linear, staircase, differential pulse, and square-wave potential sweep. The device is ideal for research laboratories in need of high quality and reliable equipment to detect toxic trace impurities; it is equally suitable for routine analysis and scientific research. TA Lab analyzer is included in the Russian Federal Registry. It is authorized for use in the EU countries and approved in Belarus, Kazakhstan and Ukraine. Detected admixtures Water Air Soil Solid waste Food products Drinks Fish products Fat products As, Cd, Pb, Cu, Zn, Mn, Hg, Se, I, Ni, Co, Fe, Ag, Sb, Bi Cd, Pb, Cu, Zn, Ni As, Cd, Pb, Cu, Zn, Mn, Hg, Ni, Co As, Cd, Pb, Cu, Zn, Mn, Hg, Ni, Co As, Cd, Pb, Cu, Zn, Se, I, Sn As, Cd, Pb, Cu, Zn, Se, I, Sn Hg, As, Cd, Pb, Cu, Zn, Se, I, Sn As, Cd, Pb, Cu, Zn, Ni, Co, Se, I Two sources of UV radiation (total power = 22W) affect the analyzed solutions from two sides, which allows: detecting Zn, Cd, Pb, Cu, I in drinking and natural water (рн>4) without preliminary sample preparation; reducing measurement time, reducing reagent consumption and increasing sensitivity of Cd, Pb, Zn, Cu, Sn, Se, I detection in water and food products. Ozone barbotage of analyzed solutions allows: detecting Hg in water without preliminary sample preparation; reducing the time of cleaning of the electrochemical cells when detecting heavy metals Vibration of indicating electrode in the course of measurements improves repeatability and increases measurement sensitivity. Metrological characteristics are estimated along with the result of analysis. Each electrode is stored and installed with a specialized cap, which prevents operator s contact with the working surface of an electrode. The equipment package is complete with the materials aimed at facilitating the training and the use of analyzer: a DVD with a video tutorial, which covers the theoretical foundations of the stripping voltammetry method and gives a detailed description of analysis procedure; a manual for analysis by means of stripping voltammetry method using TA Lab analyzer; adjustable pipettors. Each cell is equipped with light emitting diodes. The analyzer can be wirelessly connected to a computer via Bluetooth, which allows placing the analyzer as far as 10 meters away from the computer, the computer being able to perform other tasks while the work of the analyzer is in progress. The analyzer can be complete with a set of glassware and the assay kit necessary for each of the analisys techniques. The range of measurements Duration of simultaneous analysis of three prepared samples Overall dimensions mg/l 5 30 min 265х103х262 mm There are three electrochemical cells in the analyzer, so it is possible to simultaneously analyze three samples under repeatability conditions. tel./fax: +7 (3822) ,

3 PAN As ANALYZER Automated device with three measurement channels, which is intended to detect arsenic in various objects by method of stripping voltammetry without using a computer and with minimal operator involvement. Analysis automation eliminates the risk of operator mistake, reduces requirements to operator qualification and enhances productivity. Analyzer can be used for research, since it allows evaluating parameters of arsenic analytical signals in addition to visualizing them. voltammetric analyzers Measurement range of mass arsenic concentrations: in the analyzer cell solution mg/l in the drinking, natural, mineral and sewage water mg/l in food products, food stock, dietary supplements mg/kg in soil, bottom sediments mg/kg Overall dimensions 255х155х115 mm Mass 2.0 kg The presence of three working electrodes in the electrochemical cell allows obtaining three independent sample analysis results simultaneously. A touchpad located at the graphic display is used to control the PAN As analyzer operation. Analyzer use does not require training of a specialist, since analysis is performed in the interactive mode. Operator can view calibration charts and voltamperograms with arsenic analytical signal, and this enhances reliability of analysis results and confidence of operator in their accuracy. Analysis results can be saved in the archive and viewed later. The device can be connected to a computer to archive, review, and print out the results of analysis and the registered arsenic signals. Analysis results are calculated based on calibration chart and addition technique. Moreover, it is possible to simultaneously obtain and view the analysis results based on calibration chart and addition technique. In order to obtain the result based on calibration chart, operator performs three operations: adding solution of the prepared sample into the cell, entering the sample parameters and pressing the button «Start». Analysis result (arsenic concentration in the analyzed sample) and error characteristic are automatically calculated based on two (or three) independent results obtained simultaneously. Electrodes are installed into analyzer using electrode caps that prevent operator contact with the working surface of an electrode. It is possible to detect both gross arsenic content and the content of its valence forms As(III) and As(V) in various types of water. The analyzer set is complete with two adjustable pipettors to facilitate the analysis. The sample analysis on PAN As analyzer is carried out according to the analyzer manual and analyzing methods registered with the Federal Information Foundation for the Assurance of Measurement Uniformity. The analyzer set is complete with the analysis techniques and two pipettors. tel./fax: +7 (3822) ,

4 METHODOLOGY SUPPORT OF ANALYZERS Methods of analysis present a detailed and comprehensible overview of the sample preparation procedure with the indication of temperature processing, procedure of taking measurements and quality control of analysis when performed in a lab. Lower boundary of detected contents, mg/kg Detected element Food Dietary Fats Drinks Soil Objects of analysis Solid Waste Air, mg/m 3 Dishware Toys Arsenic Mercury Cadmium * Lead * Copper * Zinc * Tin Nickel * Cobalt 0.10* 0.10 Selenium Iodine Manganese *The method allows detecting water-soluble, acid-soluble elements and elements in a moving state as well as their gross contents Detected element Range of measurements, mg/l Arsenic (III) Arsenic (V) Arsenic Cadmium Lead Copper Zinc Mercury Silver Nickel Cobalt Selenium Iodine Iodides Iodates voltammetric analyzers Water: natural, drinking and waste Method features Analysis of more than 200 samples without regenerating the electrode surface. Sample preparation time is 2 hours Detection of Zn, Cd, Pb, Cu is carried out simultaneously. Express sample preparation combined with registration of analytic signal Express sample preparation; Efficient method of cleaning the cells and glassware Sample preparation within hours. Express analysis without preliminary sample preparation is possible Simultaneous detection of Co and Ni. Sample preparation within hours Electrochemical cell is subject to UV radiation to enhance analysis sensitivity and precision Express sample preparation combined with registration of analytic signal. Use of indicator electrode not requiring the use of metallic mercury and its salts Manganese Express-analysis without preliminary sample preparation and with no use of inert gas Iron One sample analysis duration no more than 5 min. Content detection in a range of mg/l is possible when the sample is concentrated by evaporation Antimony Sample preparation within hours Bismuth Sample preparation within hours tel./fax: +7 (3822) ,

5 ELECTRODES Tomanalyt produces a wide range of electrodes for voltammetric analyzers. Electrodes are equipped with protective caps to ensure safe storage and convenient installation. Dedicated injection molding technologies are used for production of electrodes. This allows arranging production of large lots of electrodes with identical parameters and low cost. Silver chloride electrode This electrode is a helix made of silver wire coated with silver chloride (AgCl), placed into a polypropylene case with semipermeable plug made of aluminum oxide (Al2O3), that is filled with potassium chloride solution (KСl). These electrodes are used as reference and auxiliary electrodes. They ensure resistance of no more than 1000 Ohm. Carbon containing electrode It consists of the polyethylene case filled with polyethylene (70%) and solid carbon composite (30%). By electrochemically applying gold, platinum or mercury to the electrode surface one obtains microelectrode ensembles characterized by high sensitivity and stability of operation. It is used to detect mercury, arsenic, silver, chrome, iron, nitrates, selenium, antimony, copper. Silver modified electrode This electrode consists of a polyethylene rod, the lower part of which contains a silver rod with a surface covered with solid solution of mercury in silver. This electrode does not require the use of metallic mercury in the process of operation. It is used as a working electrode to detect iodine, cadmium, lead and selenium. voltammetric analyzers Amalgam electrode This electrode consists of a polyethylene base, the lower part of which contains a silver rod with a silver amalgam covered surface. Mercury film is deposited on the silver surface in the analyzer cell in the automatic mode by mercury electrolysis from saturated solution of univalent mercury nitrite. In order to ensure operator safety, electrodes are installed, removed and stored in special protective caps. Electrodes are used to detect zinc, cadmium, lead, copper, manganese, antimony, bismuth, tin, nickel, cobalt, iodine, and a number of organic substances. Device for regeneration of electrode surface The device is designed to regenerate the working surface of carbon containing electrodes. The thickness of the electrode layer that is cut off is mm. Graphite, glassy carbon, silver and platinum electrodes can be made on special order. tel./fax: +7 (3822) ,

6 SOFTWARE ТA Lab software is designed to operate the TA Lab and TA Universal analyzers. TA Lab software performs the functions necessary for quick and accurate analysis of various samples and scientific voltammetry research. The software is based upon traditional principles, typical for MS Windows office programs, which facilitates its use. The program allows performing other tasks on computer while the device is in operation (Internet, typing and editing of other files). Calculation of analysis results is conducted by standard addition method and/or according to the standard. Analytical signals of the elements detected are extracted automatically, the software allowing: extracting from 1 to 99 consecutive signals under repeatability conditions; identification of signals; automatic exclusion of non-reproducible signals; auto scaling of signals; identification of signal strength. Operator can adjust the program by means of: changing the duration of any of the measurement stages; voltammetric analyzers manual exclusion of signals from the calculations; manual extraction of signals; adjusting the scale of signals displayed; recalculation of analysis results by means of signals reworking. Analysis result and error characteristics are automatically calculated based on two (or three) single measurement results obtained simultaneously in the analyzer cells. In order to calculate the result, operator can choose to use the lab estimated or assigned error characteristics (at P=0.95 and at P=0.90). It is possible to print out, store in the analysis report, archive and convert the measurement results into other MS Windows software formats. Operator can control the displayed number, position and scale of analytical signals. Software allows: creating new measurement techniques; turning-on stirring, UV radiation or barbotage of the analyzed solution with inert gas/ozone at the stage of analytical signal registration; converting the registered voltammetry charts digitally into Excel format. tel./fax: +7 (3822) ,

7 TA UNIVERSAL ANALYZER TA Universal is designed to measure ph index, mass and molar concentration of microelements, anions, cations in drinking, natural, waste water, water solutions of soil samples, food products, food stock, biological objects and other materials capable of forming solutions by means of relevant sample preparation. Wide range of the analyzer functional capabilities can satisfy the needs of a small testing lab as well as a research and development center. voltammetric analyzers The range of measurements by potentiometry method: hydrogen index ph molar concentration of anions and cations mole/l Range of mass concentration measurements by method of mg/l stripping voltammetry Time of analysis of three prepared 5 30 min samples Overall dimensions 265х90х262 mm Mass 2.9 kg The standardized and certified measurement techniques include the requirements for measurement error of molar mass concentration of elements, anions and cations in various objects by potentiometry and voltammetry methods. The only analyzer combining the functions of a voltammetry analyzer and a ph meter/ionometer. TA Universal includes: one cell for measurement by potentiometry method; three cells with solution backlight for voltammetric analysis making it possible to simultaneously achieve three analysis results; two sources of UV radiation (total power = 22W) designed to irradiate solutions for voltammetric analysis; temperature sensor to measure the temperature of the solutions analyzed. TA Universal operates under computerized control offering the possibility of analysis by direct potentiometry and direct, cyclic and stripping voltammetry methods. Mixing in the electrochemical cells for voltammetry measurements is carried out by vibration of indicating electrode and by submersible stirrer in the electrochemical cells for potentiometry measurements. The duration and intensity of mixing is set and controlled by software. Temperature autocompensation is carried out when measuring ph. The analyzer can be complete with set of various types of electrodes including electrode combination. Calculation of analysis result is performed automatically taking into account the lab error characteristics. Software allows: displaying the registered data in a graphic and digital form; archiving the results of measurements; creating new measurement techniques. tel./fax: +7 (3822) ,

8 рh meter/ion meters ITAN ph meter/ion meter Itan is a table based automated device, which includes LCD with a sensor control panel, in built magnetic stirrer and a rack for electrodes. The device is designed to measure ph, px, molar and mass concentrations of ions, and oxidation reduction potentials (Eh) by potentiometry method. Measurement range: hydrogen index ph molar concentration of anions and cations mole/l solution temperature о С Limits of the main admissible absolute error of hydrogen index measurement: by measuring transmitter ± ph by measuring transmitter complete with electrode system in solutions with temperature of (25.0±0.5) о С by measuring transmitter complete with electrode system in solutions with temperature from 10 to 60 о С Limits of the main admissible relative error of molar anion and cation concentration measurement with a measuring transmitter Overall dimensions Mass ±0.030 ph ±0.050 ph ±1.0 % 260x155x100 mm 1.3 kg Magnetic stirrer and electrode rack are integrated into the analyzer body. Device is compatible with all types of electrodes including electrode combinations. Metallic case is resistant to chemical and mechanic impact. Calibration chart can be constructed based on 2 10 points. Calibration chart can be displayed in the form of a table or a graph. Calibration chart is linearized and outlying points are automatically excluded. Steepness of the electrode function is calculated and compared with its certified value for the electrode. Calibration chart is verified on the basis of one or two standard solutions. Temperature compensated measurement of ph with respect to isopotential point coordinates of the electrode used. Automatic or manual process end after potential is stabilized at operator s will. Automatic calculation of analysis result based on two to four individual measurements taking into account the method accuracy and repeatability indicators. Calculation of analysis results in рх units, mole/l (mole/kg), mg/l (mg/kg) taking into account the analyzed sample parameters. Temperature of the analyzed solution is displayed on the screen. Measurement results, electrode characteristics and measurement parameters are stored in the analyzer memory. Stirring with magnetic stirrer is controlled in the automatic mode by setting the relevant commands in technique parameters (stirring level, presence of stirring before and during measurement). Stirring of solutions can be carried out independently of the measurements if the duration and the level of stirring are controlled. tel./fax: +7 (3822) ,

9 рh meter/ion meters TA ION ph meter/ion meter TA Ion is a desktop automated device, which includes an integrated cup holder for the analyzed solution, a magnetic stirrer and rack with a clamp for electrodes. Control over device operation, as well as processing, display and storage of measurement results are carried out by computer installed software. TA Ion is designed to measure ph, molar concentration of anions and cations by potentiometry method in drinking, natural, sewage waters, water solutions of soil samples, food products, food stock, biological objects and other materials capable of forming solutions under relevant sample preparation. Measurement range: hydrogen index ph Molar concentration of anions and cations mole/l solution temperature о С Limits of the main admissible absolute error of hydrogen index measurement: by measuring transmitter ± ph by measuring transmitter complete with electrode system in solutions ± ph with temperature of (25.0±0.5) о С by measuring transmitter complete with electrode system in solutions with temperature from 10 to 60 о С Limits of the main admissible relative error of molar anion and cation concentration measurement with a measuring transmitter Overall dimensions Mass ±0.040 ph ±1.0 % 90x145x53 mm 0.5 kg ph meter/ion meter is powered via computer USB-port. Stirring with magnetic stirrer is controlled in the automatic mode by setting the relevant commands in technique parameters (stirring duration and intensity, measurement stage). Temperature compensated measurement of ph is carried out with respect to isopotential point coordinates of the electrode used. The process ends after potential is stabilized automatically or manually at operator s will. Calculation of analysis result is carried out automatically based on 2 to 15 individual measurements taking into account the method accuracy and repeatability indicators. Equation and correlation coefficient of the calibration chart are calculated and the calibration chart characteristics are automatically compared with certified data of the electrode used. Calibration chart is verified on the basis of one or two standard solutions. Calibration chart is linearized and outlying points are automatically excluded. Possibility to construct calibration chart based on 2 15 points. Possibility to view calibration chart as a table or as a graph. Measurement of potential in the course of measurement in each solution is displayed as a graph and as a table. Calculation of the analysis result in px, mole/l (mole/kg), mg/l (mg/kg) units taking into account parameters of the analyzed sample. Temperature of the analyzed solution is displayed on the screen. Calibration charts, measurement results, parameters of measurement techniques, electrode characteristics are stored in the computer memory. Software interface can be set at operator s convenience. It is possible to print out and convert the measurement results into other software formats. tel./fax: +7 (3822) ,

10 PROGRAMMABLE TWO CHAMBER PDP FURNACES We offer a series of programmable sample preparation devices for convenience and improved efficiency of sample preparation. Programmable two chamber furnaces are space efficient, high speed devices designed for vaporization and cineration of samples for subsequent analysis by various methods. Furnaces are controlled by a control panel that sets and stores no less than 9 programs of thermal sample treatment in its memory. Each program can include up to 9 stages with set values of time and temperature. sample preparation devices Range of working temperatures in the working volume of the cineration chamber Non-uniformity of temperature in the volume of cineration chamber Time of the cineration chamber heating up to 700 С Range of working temperatures of the vaporization chamber heating surface о С ± 5 о С 18 min С Overall sizes PDP-Lab PDP Analytica Furnace 30х210х200 mm 430х230х220 mm Control panel 185х85х35 mm 185х85х35 mm Vaporization chamber heating 278х41 mm 300х80 mm surface Cineration chamber 278х68х80 mm 278х68х80 mm Cineration chamber 1.4 L 1.4 L Mass 4.5 kg 5.5 kg PDP furnaces include: closed muffle type chamber; semi closed (or open) electric hot plate type chamber placed upon the muffle type chamber; control panel offering 9 programs of thermal treatment for each chamber and up to 9 automatically temperature and time controlled stages in each program. The furnace set comprises: quartz crucibles of the volume indicated by the customer: 20 cm 3, 50 cm 3, 65 cm 3, 100 cm 3 ; methodology guidelines on mineralization of food product samples; appraisal technique. Vaporization and cineration processes are controlled independently and can be performed simultaneously. Components of furnace case are made of stainless steel, which makes it possible to use it in the presence of aggressive acid vapors. Possibility of setting and storing 9 programs of thermal sample treatment stages for each chamber in the memory. In the course of device operation, depending on the intensity of the process it is possible: to decrease or increase (up to 999 min.) the time of thermal treatment; to manually switch to one of the following or preceding stages of the set thermal treatment program. Sample preparation time: beverages hours fish, milk hours meat, coffee, tea hours fats, oils hours grits, grains, flour hours. tel./fax: +7 (3822) ,

11 sample preparation devices We offer a series of specialized sample preparation devices for convenience and improved efficiency of sample preparation for analysis. PROGRAMMABLE SECTION PLATE PSP 2 ADJUSTABLE PLATE RP 1 This is an electrical plate with adjustable temperature of the heating surface. The mode of operation is controlled by a temperature regulating knob. This is an electric plate with two heating surfaces, which can operate simultaneously or independently at different temperature settings. Control panel sets and controls the plate parameters and modes. The control panel offers: programs of thermal treatment for each section 9; automatically temperature and time controlled stages in each program from 1 to 9; time of stage implementation from the moment of set temperature achievement min. Programming of temperature settings allows conducting uniform vaporization of huge volumes of liquid samples with no additional supervision by the operator. Range of working temperatures of the heated plates Time of plate heating up to maximum temperature Circuit insulation resistance (in normal conditions) Overall dimensions: С 20 min 20 MOhm plate 330х320х120 mm heating surface 220х285 mm Mass 3 kg Range of working temperatures of the heated plates С Cover material of the plate working surface aluminum oxide Time of section heating-up to maximum temperature 20 min Overall dimensions: control panel 185х85х35 mm two section plate 440х360х120 mm single heating plate 170х270 mm Mass 5.7 kg OZONE GENERATOR TA OZONE TA Ozone is designed to drive ozone through electro- chemical cells of voltammetric analyzers TA Lab, TA 4, TA Universal and to clean chemical glassware. Ozone generator is used for: cleaning electrochemical cells when detecting mercury in various objects; preparing water samples for analysis when detecting mercury content by stripping voltammetry method; cleaning chemical glassware used for mercury detection by various methods; cleaning chemical glassware of detected elements contents when analyzing water by the method of stripping voltammetry. tel./fax: +7 (3822) ,

12

The challenges of field sensors for trace metal detection. Chris Searle Product Manager Trace2o Ltd

The challenges of field sensors for trace metal detection. Chris Searle Product Manager Trace2o Ltd The challenges of field sensors for trace metal detection Chris Searle Product Manager Trace2o Ltd What is a heavy metal and why is it necessary to determine concentration? Tends to be categorised as Metallic

More information

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium, 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable Compact Titration Compact Titrator G20 One Click Titration Simple & Dependable Simplicity The Intelligent Helper for Simple Titrations One Click Titration Intuitive method adaptation Accurate results simply

More information

ANALYSIS CERTIFICATE OF

ANALYSIS CERTIFICATE OF CERTIFICATE OF ANALYSIS 300 Technology Drive Christiansburg, VA 24073. USA inorganicventures.com tel: 800.669.6799. 540.585.3030 fax: 540.585.3012 info@inorganicventures.com 1.0 INORGANIC VENTURES is an

More information

Welcome to Honors Chemistry!

Welcome to Honors Chemistry! Welcome to Honors Chemistry! Congratulations on taking Honors Chemistry next year! This summer assignment is designed to assess your reading comprehension and interpreting graph skills; review how to make

More information

Welcome to Honors Chemistry!

Welcome to Honors Chemistry! Welcome to Honors Chemistry! Congratulations on taking Honors Chemistry next year! This summer assignment is designed to assess your reading comprehension and interpreting graph skills; review how to make

More information

Name Date. Fall Semester Review Classify each of the following as to whether it is an element, compound, or mixture and draw a picture for each.

Name Date. Fall Semester Review Classify each of the following as to whether it is an element, compound, or mixture and draw a picture for each. Name Date Fall Semester Review 2014 Classify each of the following as to whether it is an element, compound, or mixture and draw a picture for each. 1. chlorine 5. carbon dioxide 8. rubbing alcohol E C

More information

Solved Examples On Electrochemistry

Solved Examples On Electrochemistry Solved Examples On Electrochemistry Example 1. Find the charge in coulomb on 1 g-ion of Charge on one ion of N 3- = 3 1.6 10-19 coulomb Thus, charge on one g-ion of N 3- = 3 1.6 10-19 6.02 10 23 = 2.89

More information

Prof. Dr. Biljana Škrbić, Jelena Živančev

Prof. Dr. Biljana Škrbić, Jelena Živančev 5 th CEFSER Training Course Analysis of chemical contaminants in food and the environment Faculty of Technology, University of Novi Sad, Novi Sad, Republic of Serbia 7-11 May 2012 Analysis of heavy elements

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

ph Probe ReallyEasyData com

ph Probe ReallyEasyData com ph Probe 9200001 Uses Whether you re monitoring ph for chemistry, physical science, life science, or earth science activity, this ph meter offers accurate readings in a convenient format. Use the RED ph

More information

To precipitate nickel (II) sulfide, the sulfide ion concentration must be a lot larger:

To precipitate nickel (II) sulfide, the sulfide ion concentration must be a lot larger: EXPERIMENT 13-14 Qualitative Analysis of Group II Cations THE GROUP II AND GROUP III PRECIPITATING AGENT Once the group I cations have been precipitated out of an unknown solution, and the precipitates

More information

Chapter 1 -- Introduction to Qualitative Analysis. NAME: Lab Section: Date: Sign-Off:

Chapter 1 -- Introduction to Qualitative Analysis. NAME: Lab Section: Date: Sign-Off: Chapter 1 -- Introduction to Qualitative Analysis NAME: Lab Section: Date: Sign-Off: Chapter 1 -- Introduction to Qualitative Analysis Introduction Qualitative analysis is a way inorganic chemists have

More information

materials and their properties

materials and their properties materials and their properties macroscopic properties phase state strength / stiffness electrical conductivity chemical properties color / transparence spectroscopical properties surface properties density

More information

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer Innovative 0.01 0.1 1 10 Intuitive Concentration (ppb) R = 0.99999 Versatile Hydra II C Mercury Analyzer At Teledyne Leeman Labs; atomic spectroscopy is our business our only business. We are industry

More information

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable Compact Titration Compact Titrator G20 One Click Titration Simple & Dependable Simplicity The Intelligent Helper for Simple Titrations One Click Titration Intuitive method adaptation Accurate results simply

More information

ADI2045VA Process Analyzer

ADI2045VA Process Analyzer ADI2045VA Process Analyzer Trace Metal and Plating Bath Analysis Trace Metal and Plating Bath Analysis Metrohm Applikon On-Line Analyzers Metrohm Applikon B.V. has over 25 years of experience with on-line

More information

elemental state. There are two different possibilities: DESCRIPTION 1. One cation (+ ion) replaces another. 2. One anion (- ion) replaces another.

elemental state. There are two different possibilities: DESCRIPTION 1. One cation (+ ion) replaces another. 2. One anion (- ion) replaces another. CHEMICAL TYPES HANDOUT In these reactions, a free element reacts with a compound to form another compound and release one of the elements of the original compound in the elemental state. There are two

More information

Oxidation-Reduction (Redox)

Oxidation-Reduction (Redox) Oxidation-Reduction (Redox) Electrochemistry involves the study of the conversions between chemical and electrical energy. Voltaic (galvanic) cells use chemical reactions to produce an electric current.

More information

Basic Digestion Principles

Basic Digestion Principles Basic Digestion Principles 1 From Samples to Solutions Direct Analytical Method Solid Sample Problems: Mech. Sample Preparation (Grinding, Sieving, Weighing, Pressing, Polishing,...) Solid Sample Autosampler

More information

Redox Reactions and Electrochemistry

Redox Reactions and Electrochemistry Redox Reactions and Electrochemistry Redox Reactions and Electrochemistry Redox Reactions (19.1) Galvanic Cells (19.2) Standard Reduction Potentials (19.3) Thermodynamics of Redox Reactions (19.4) The

More information

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code DONATELLO FAST Automatic floor closed cycle tissue processor for histological specimens Automatic tissue processor for histological specimens DONATELLO FAST code PRO0 RI General characteristics DONATELLO

More information

Chemistry 213. Electrochemistry

Chemistry 213. Electrochemistry Chemistry 213 Electrochemistry Part A: Electrochemical Cells Objective Oxidation/reduction reactions find their most important use in the construction of voltaic cells (chemical batteries). In this experiment,

More information

CHEMISTRY 13 Electrochemistry Supplementary Problems

CHEMISTRY 13 Electrochemistry Supplementary Problems 1. When the redox equation CHEMISTRY 13 Electrochemistry Supplementary Problems MnO 4 (aq) + H + (aq) + H 3 AsO 3 (aq) Mn 2+ (aq) + H 3 AsO 4 (aq) + H 2 O(l) is properly balanced, the coefficients will

More information

Residual Chlorine Monitor

Residual Chlorine Monitor Data Sheet SS/AW00 Issue Residual Chlorine Monitor AW00 Total and Free Residual Chlorine Measurement add potassium iodide to reagent to convert free chlorine measurement to total chlorine Reagentless Operation

More information

SOME ASPECTS OF COOLANT CHEMISTRY SAFETY REGULATIONS AT RUSSIA S NPP WITH FAST REACTORS

SOME ASPECTS OF COOLANT CHEMISTRY SAFETY REGULATIONS AT RUSSIA S NPP WITH FAST REACTORS Federal Environmental, Industrial and Nuclear Supervision Service Scientific and Engineering Centre for Nuclear and Radiation Safety Scientific and Engineering Centre for Nuclear and Radiation Safety Member

More information

AP CHEMISTRY NOTES 12-1 ELECTROCHEMISTRY: ELECTROCHEMICAL CELLS

AP CHEMISTRY NOTES 12-1 ELECTROCHEMISTRY: ELECTROCHEMICAL CELLS AP CHEMISTRY NOTES 12-1 ELECTROCHEMISTRY: ELECTROCHEMICAL CELLS Review: OXIDATION-REDUCTION REACTIONS the changes that occur when electrons are transferred between reactants (also known as a redox reaction)

More information

Rapid Sample Assessment and Simplified Method Development with IntelliQuant

Rapid Sample Assessment and Simplified Method Development with IntelliQuant Rapid Sample Assessment and Simplified Method Development with IntelliQuant Technical Overview Introduction In addition to routine quantitative elemental analyses using ICP-OES, analytical laboratories

More information

Electrochemistry Worksheets

Electrochemistry Worksheets Electrochemistry Worksheets Donald Calbreath, Ph.D. Say Thanks to the Authors Click http://www.ck12.org/saythanks (No sign in required) To access a customizable version of this book, as well as other interactive

More information

Chemistry: The Study of Change Chang & Goldsby 12 th edition

Chemistry: The Study of Change Chang & Goldsby 12 th edition Chemistry: The Study of Change Chang & Goldsby 12 th edition modified by Dr. Hahn Chapter 1 Chemistry: A Science for the 21 st Century (2) Materials and Technology Polymers, liquid crystals photovoltaic

More information

Unit 3 Atomic Structure

Unit 3 Atomic Structure Name: Unit 3 Atomic Structure Scientist Year Contribution and/ or Experimental Work Democritus Aristotle Alchemists Boyle Franklin Dalton Avogadro Mendeleev Moseley 1 Scientist Year Contribution and/ or

More information

Electrochemistry. Conductivity of strong and weak electrolytes LEC 06. What you need: What you can learn about. Principle and tasks

Electrochemistry. Conductivity of strong and weak electrolytes LEC 06. What you need: What you can learn about. Principle and tasks LEC 06 Electrochemistry What you can learn about Kohlrausch s law Equivalent conductivity Temperature-dependence of conductivity Ostwald s dilution law Principle and tasks It is possible to differentiate

More information

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and

More information

SOP-C-120 Determination of ph

SOP-C-120 Determination of ph i. Identification of the method a. SM 4500-H + (approved 2011) and EPA 9045C (approved 1997) ii. Applicable matrix or matrices a. Waters or aqueous solutions and suspensions iii. Limits of detection and

More information

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities instruments 5 YEARS G U A R A N T E E Quality at a reasonable price The optimum combination

More information

CHAPTER 5 REVIEW. C. CO 2 D. Fe 2 O 3. A. Fe B. CO

CHAPTER 5 REVIEW. C. CO 2 D. Fe 2 O 3. A. Fe B. CO CHAPTER 5 REVIEW 1. The following represents the process used to produce iron from iron III oxide: Fe 2 O 3 + 3CO 2Fe + 3CO 2 What is the reducing agent in this process? A. Fe B. CO C. CO 2 D. Fe 2 O 3

More information

Titration of a strong acid with a strong base with Cobra4

Titration of a strong acid with a strong base with Cobra4 Titration of a strong acid with a strong base with Cobra4 TEC Related topics Strong and weak acids and bases, ph value, titration curves, equivalence point, potentiometry. Principle Hydrochloric acid is

More information

Experiment 6. Investigating Chemical Reactions

Experiment 6. Investigating Chemical Reactions In this experiment you will: Experiment 6. Investigating Chemical Reactions Perform and observe the results of a variety of chemical reactions. Become familiar with the observable signs of chemical reactions.

More information

Voltammetry. Voltammetry. An Introduction in Theory. Metrohm Ltd. CH-9100 Herisau Switzerland

Voltammetry. Voltammetry. An Introduction in Theory. Metrohm Ltd. CH-9100 Herisau Switzerland An Introduction in Theory Metrohm Ltd. CH-9100 Herisau Switzerland Overview What is? Electrode Types Voltammetric Techniques Measurement Modes Calibration Techniques Advantages of Summary = Volt-Am(pero)-Metry

More information

Gamma and X-Ray Standards

Gamma and X-Ray Standards Gamma and X-Ray Standards A wide range of gamma and x-ray standards for research and educational use are available in the energy range of 5.9 to 2614 kev. Many nuclides are available up to 100 µci (3.7

More information

AP Questions: Electrochemistry

AP Questions: Electrochemistry AP Questions: Electrochemistry I 2 + 2 S 2O 2-3 2 I - + S 4O 2-6 How many moles of I 2 was produced during the electrolysis? The hydrogen gas produced at the cathode during the electrolysis was collected

More information

Lab #14: Electrochemical Cells

Lab #14: Electrochemical Cells Lab #14: Electrochemical Cells Objectives: 1. To understand the nature of electrochemical cells. 2. To construct a table listing the reduction potentials of a series of metal ions, in order of ease of

More information

ICP/MS Multi-Element Standards

ICP/MS Multi-Element Standards Standards Ultra Pure Matrix Special Packaging Traceability to National Reference Materials AccuStandard s ICP/MS Standards are formulated to meet the needs of this very special instrument. As matrix effect

More information

Entry Guide for "DIC RAW MATERIAL SURVEY" for Form Version 4.1

Entry Guide for DIC RAW MATERIAL SURVEY for Form Version 4.1 Entry Guide for "DIC RAW MATERIAL SURVEY" for Form Version 4.1 - Find proper selection among drop-down list if explanation below is marked with "*". - You can leave from an inquiry cell empty if your SDS

More information

Chemistry: The Central Science. Chapter 20: Electrochemistry

Chemistry: The Central Science. Chapter 20: Electrochemistry Chemistry: The Central Science Chapter 20: Electrochemistry Redox reaction power batteries Electrochemistry is the study of the relationships between electricity and chemical reactions o It includes the

More information

Voltammetry. Voltammetry and Polarograph. Chapter 23. Polarographic curves -- Voltammograms

Voltammetry. Voltammetry and Polarograph. Chapter 23. Polarographic curves -- Voltammograms Chapter 23 Voltammetry Voltammetry and Polarograph Electrochemistry techniques based on current (i) measurement as function of voltage (E appl ) Voltammetry Usually when the working electrode is solid,

More information

Chapter 3-1. proton positive nucleus 1 amu neutron zero nucleus 1 amu electron negative on energy levels around the nucleus very small

Chapter 3-1. proton positive nucleus 1 amu neutron zero nucleus 1 amu electron negative on energy levels around the nucleus very small Chapter 3-1 Sub-atomic Charge Location Mass Particle proton positive nucleus 1 amu neutron zero nucleus 1 amu electron negative on energy levels around the nucleus very small The most mass of the atom

More information

novaa 800 D Atomic Absorption Spectrometer

novaa 800 D Atomic Absorption Spectrometer Technical Data Atomic Absorption Spectrometer Cpt : +27 (0) 21 905 0476 Jhb : +27 (0) 11 794 Dbn : +27 (0) 31 266 2454 1/7 General The is a compact atomic absorption spectrometer with deuterium background

More information

Current based methods

Current based methods Current based methods Amperometric and voltammetric sensors More significant influence on analytical parameters (sensitivity, selectivity, interferences elimination) kind of method, potential range, electrode

More information

Fig. Electrochemical Cell/ Potentiometric Titration

Fig. Electrochemical Cell/ Potentiometric Titration Fig. Electrochemical Cell/ Potentiometric Titration The accurate, precise and effective potentiometric measurements can be made with the help of the following two types of electrodes namely : REFERENCE

More information

F- Cl- Br- I- CN- S2- NO3-

F- Cl- Br- I- CN- S2- NO3- Middle of the 60 s First ISE for fluoride Na+ K+ Ag+ Ca2+ NH + 4 Cu2+ Pb2+ F- Cl- Br- I- CN- S2- NO3- Environment Food industry and agriculture Medecine, pharmaceutical, cosmetics Power plants Fluoride

More information

CHAPTER ELECTROCHEMISTRY

CHAPTER ELECTROCHEMISTRY 149 CHAPTER ELECTROCHEMISTRY 1. On electrolysis of dilute sulphuric acid using platinum electrodes, the product obtained at the anode will be hydrogen oxygen hydrogen sulphide sulphur dioxide 2. Which

More information

Electrochemistry. A. Na B. Ba C. S D. N E. Al. 2. What is the oxidation state of Xe in XeO 4? A +8 B +6 C +4 D +2 E 0

Electrochemistry. A. Na B. Ba C. S D. N E. Al. 2. What is the oxidation state of Xe in XeO 4? A +8 B +6 C +4 D +2 E 0 Electrochemistry 1. Element M reacts with oxygen to from an oxide with the formula MO. When MO is dissolved in water, the resulting solution is basic. Element M is most likely: A. Na B. Ba C. S D. N E.

More information

Module 4 : THERMOELECTRICITY Lecture 21 : Seebeck Effect

Module 4 : THERMOELECTRICITY Lecture 21 : Seebeck Effect Module 4 : THERMOELECTRICITY Lecture 21 : Seebeck Effect Objectives In this lecture you will learn the following Seebeck effect and thermo-emf. Thermoelectric series of metals which can be used to form

More information

ELEMENTS AND COMPOUNDS

ELEMENTS AND COMPOUNDS C03 04/19/2013 13:31:38 Page 20 CHAPTER 3 ELEMENTS AND COMPOUNDS SOLUTIONS TO REVIEW QUESTIONS 1. Silicon 25:7% Hydrogen 0:9% In 100 g 25:7g Si 0:9g H ¼ 30 g Si=1 g H ð 1 sig: fig: Þ Si is 28 times heavier

More information

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy Evrim Kilicgedik Product Specialist, Atomic Spectroscopy Agilent Technologies 04.11.2011 2011 The Atomic Spectroscopy

More information

Heavy metal analysis of river water using the ItalSens HM1 sensor

Heavy metal analysis of river water using the ItalSens HM1 sensor Heavy metal analysis of river water using the ItalSens HM1 sensor Quantification of copper, lead and cadmium in aqueous solutions Last revision: December 15, 2015 2014 PalmSens BV www.palmsens.com Contents

More information

Lab: Types of Chemical Reactions Safety is very important when combining chemicals

Lab: Types of Chemical Reactions Safety is very important when combining chemicals Safety is very important when combining chemicals Students: Please read the following information given below, and then come to class on your lab day with the following already prepared in your notebooks:

More information

Electrochemistry 1 1

Electrochemistry 1 1 Electrochemistry 1 1 Half-Reactions 1. Balancing Oxidation Reduction Reactions in Acidic and Basic Solutions Voltaic Cells 2. Construction of Voltaic Cells 3. Notation for Voltaic Cells 4. Cell Potential

More information

Test Procedure for ItalSens IS-1 Graphite Sensors

Test Procedure for ItalSens IS-1 Graphite Sensors Test Procedure for ItalSens IS-1 Graphite Sensors Using Naphthol Oxidation to Check the Electrode Stability or Detect Naphthol Last revision: December 16, 2015 2015 PalmSens BV www.palmsens.com Contents

More information

Electrochemical Cells

Electrochemical Cells Electrochemical Cells There are two types: Galvanic and Electrolytic Galvanic Cell: a cell in which a is used to produce electrical energy, i.e., Chemical energy is transformed into Electrical energy.

More information

c formula units of potassium iodide a moles of beryllium b moles of calcium c mole of sulfur a. 6.

c formula units of potassium iodide a moles of beryllium b moles of calcium c mole of sulfur a. 6. Chapter 11 1. Identify and calculate the number of representative particles in each of the following quantities. a. 2.15 moles of gold 2.15 mol Au 1.29 10 24 atoms Au b. 0.151 mole of nitrogen oxide 0.15O

More information

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer: ASTORIA-PACIFIC rapid-t with Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer: Durable. Accurate. Precise. Economical Open software

More information

Unit IV: Chemical Equations & Stoichiometry

Unit IV: Chemical Equations & Stoichiometry Unit IV: Chemical Equations & Stoichiometry A. The chemical equation B. Types of chemical reactions A. Activity series of metals B. Solubility rules C. Rules for writing and balancing equations D. Calculations

More information

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction application Note Atomic Absorption Authors David Bass Senior Product Specialist Cynthia P. Bosnak Senior Product Specialist PerkinElmer, Inc. Shelton, CT 06484 USA The Determination of Toxic, Trace, and

More information

Electrochemical cells. Section 21.1

Electrochemical cells. Section 21.1 Electrochemical cells Section 21.1 Electrochemical processes Chemical process either release energy or absorb energy This does not have to be solely heat or light - sometimes it can be in the form of electricity

More information

Oxidation-Reduction Reactions and Introduction to Electrochemistry

Oxidation-Reduction Reactions and Introduction to Electrochemistry ADVANCED PLACEMENT CHEMISTRY Oxidation-Reduction Reactions and Introduction to Electrochemistry Students will be able to: identify oxidation and reduction of chemical species; identify oxidants and reductants

More information

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast Application Note Environmental Authors Austin Schultz and Jake Unnerstall, Elemental Scientific, Omaha NE, USA Steve Wilbur,

More information

Definition 1 An element or compound is oxidized when it gains oxygen atoms

Definition 1 An element or compound is oxidized when it gains oxygen atoms Oxidation and Reduction Part I Learning Outcomes 1. Introduction to oxidation and reduction: simple examples only, e.g. Na with Cl 2, Mg with O 2, Zn with Cu 2+. 2. Oxidation and reduction in terms of

More information

CHEM N-12 November In the electrolytic production of Al, what mass of Al can be deposited in 2.00 hours by a current of 1.8 A?

CHEM N-12 November In the electrolytic production of Al, what mass of Al can be deposited in 2.00 hours by a current of 1.8 A? CHEM161 014-N-1 November 014 In the electrolytic production of Al, what mass of Al can be deposited in.00 hours by a current of 1.8 A? What products would you expect at the anode and the cathode on electrolysis

More information

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer is powerful simultaneous full

More information

OXEA - Online Elemental Analyzer

OXEA - Online Elemental Analyzer 02 25 08 OXEA - Online Elemental Analyzer OXEA (Online X-ray Elemental Analyzer) is based on the X-ray fluorescence technology (XRF) which is well known in the laboratory field. With the aid of a patented

More information

PROVINCIAL EXAMINATION MINISTRY OF EDUCATION CHEMISTRY 12 GENERAL INSTRUCTIONS

PROVINCIAL EXAMINATION MINISTRY OF EDUCATION CHEMISTRY 12 GENERAL INSTRUCTIONS INSERT STUDENT I.D. NUMBER (PEN) STICKER IN THIS SPACE APRIL 1996 PROVINCIAL EXAMINATION MINISTRY OF EDUCATION CHEMISTRY 12 GENERAL INSTRUCTIONS 1. Insert the stickers with your Student I.D. Number (PEN)

More information

Speed and flexibility

Speed and flexibility Speed and flexibility Automate your environmental, water, detergent, food and beverage analysis Thermo Scientific Gallery and Gallery Plus discrete industrial analyzers Improve productivity, reproducible

More information

EXPERIMENT 10: Precipitation Reactions

EXPERIMENT 10: Precipitation Reactions EXPERIMENT 10: Precipitation Reactions Metathesis Reactions in Aqueous Solutions (Double Displacement Reactions) Purpose a) Identify the ions present in various aqueous solutions. b) Systematically combine

More information

Introduction to electrochemistry

Introduction to electrochemistry Introduction to electrochemistry Oxidation reduction reactions involve energy changes. Because these reactions involve electronic transfer, the net release or net absorption of energy can occur in the

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

Chromazurol S Method Method to 0.50 mg/l Al TNTplus 848

Chromazurol S Method Method to 0.50 mg/l Al TNTplus 848 Aluminum DOC316.53.01004 Chromazurol S Method Method 10215 0.02 to 0.50 mg/l Al TNTplus 848 Scope and application: For drinking water, surface water, swimming pool water, wastewater and process analysis.

More information

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219 REX Evaluation Guide American Micro Detection Systems Inc. 2800 March Lane, Suite 200 Stockton, CA 95219 I. INTRODUCTION REX (Real-time Elemental X-ray Fluorescence System) is the only instrument capable

More information

S8 TIGER Series 2 for ASTM D 6443

S8 TIGER Series 2 for ASTM D 6443 Lab Report XRF 139 S8 TIGER Series 2 for ASTM D 6443 Standard Test Method for Determination of Ca, Cl, Cu, Mg, P, S and Zn in Unused Lubricating Oils and Additives Introduction Lubricating oils are generally

More information

Chlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting.

Chlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting. Chlorine, Total DOC316.53.01497 USEPA DPD Method 1 Method 10260 0.04 to 10.00 mg/l as Cl 2 Chemkey Reagents Scope and application: For drinking water. This product has not been evaluated to test for chlorine

More information

POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA

POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA Introduction In this experiment, students will familiarize themselves with potentiometric titration, practice using the first derivative to find the equivalence

More information

#13 Electrochemical Cells

#13 Electrochemical Cells #13 Electrochemical Cells If a copper strip is placed in a solution of copper ions, one of the following reactions may occur: Cu 2+ + 2e - Cu Cu Cu 2+ + 2e - The electrical potential that would be developed

More information

Q1. Why does the conductivity of a solution decrease with dilution?

Q1. Why does the conductivity of a solution decrease with dilution? Q1. Why does the conductivity of a solution decrease with dilution? A1. Conductivity of a solution is the conductance of ions present in a unit volume of the solution. On dilution the number of ions per

More information

The first address for Titration. TITRONIC 300 and TitroLine 5000

The first address for Titration. TITRONIC 300 and TitroLine 5000 The first address for Titration TITRONIC 300 and TitroLine 5000 Selection table titration piston burettes TITRONIC and automatic titrators TitroLine The most important features of titrators TitroLine and

More information

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer ECS 8020 CHNS-O Analyzer Organic Elemental Analysis ECS 8020 is a C-H-N-S-O Elemental Analyzer Model based on the Dumas combustion method. ECS 8020 is

More information

Practical 1P3 Electrode Potentials

Practical 1P3 Electrode Potentials Practical 1P3 Electrode Potentials What you should learn from this practical Science This experiment will familiarise you with the thermodynamics of solutions and show how easily thermodynamic quantities

More information

(c) In marble, we assign calcium ion an oxidation number of +2, and oxygen a value of 2. We can determine the value of carbon in CaCO 3 as follows:

(c) In marble, we assign calcium ion an oxidation number of +2, and oxygen a value of 2. We can determine the value of carbon in CaCO 3 as follows: Example Exercise 17.1 Calculating Oxidation Numbers for Carbon Calculate the oxidation number for carbon in each of the following compounds: (a) diamond, C (b) dry ice, CO 2 (c) marble, CaCO 3 (d) baking

More information

Exercise 2-2. Titration of a Strong Acid EXERCISE OBJECTIVES

Exercise 2-2. Titration of a Strong Acid EXERCISE OBJECTIVES Exercise 2-2 Titration of a Strong Acid EXERCISE OBJECTIVES To describe the effect of a ph variation on a chemical indicator; To titrate water containing a strong base solution with a strong acid solution;

More information

Electrochemistry and the Nernst Equation

Electrochemistry and the Nernst Equation Experiment Electrochemistry and the Nernst Equation The CCLI Initiative Computers in Chemistry Laboratory Instruction The objectives of this experiment are to... LEARNING OBJECTIVES construct galvanic

More information

Chemistry 213. Electrochemistry I

Chemistry 213. Electrochemistry I 1 Chemistry 213 Electrochemistry I Electrochemical Cells Objective Oxidation/reduction reactions find their most important use in the construction of voltaic cells (chemical batteries). In this experiment,

More information

PRELIMINARY ACTIVITY FOR

PRELIMINARY ACTIVITY FOR PRELIMINARY ACTIVITY FOR Beer s Law Investigations Guided Inquiry Version Experiment 11 The primary objective of this Preliminary Activity is to determine the concentration of an unknown copper (II) sulfate

More information

Unit #8, Chapter 10 Outline Electrochemistry and Redox Reactions

Unit #8, Chapter 10 Outline Electrochemistry and Redox Reactions Unit #8, Chapter 10 Outline Electrochemistry and Redox Reactions Lesson Topics Covered Homework Questions and Assignments 1 Introduction to Electrochemistry definitions 1. Read pages 462 467 2. On page

More information

Chapter 19: Oxidation - Reduction Reactions

Chapter 19: Oxidation - Reduction Reactions Chapter 19: Oxidation - Reduction Reactions 19-1 Oxidation and Reduction I. Oxidation States A. The oxidation rules (as summarized by Mr. Allan) 1. In compounds, hydrogen has an oxidation # of +1. In compounds,

More information

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically Complete Set ph PRO Controller - 1 pcs. ph electrode - 1 pcs. Calibration

More information

Chemical Behavior of Metals

Chemical Behavior of Metals Activity 3 Chemical Behavior of Metals GOALS In this activity you will: Test different metals to determine their relative reactivity. Explore the concept of valence electrons. Use the process of electroplating

More information

Reactions in aqueous solutions Redox reactions

Reactions in aqueous solutions Redox reactions Reactions in aqueous solutions Redox reactions Redox reactions In precipitation reactions, cations and anions come together to form an insoluble ionic compound. In neutralization reactions, H + ions and

More information

(18) WMP/Jun10/CHEM5

(18) WMP/Jun10/CHEM5 Electrochemistry 18 7 The electrons transferred in redox reactions can be used by electrochemical cells to provide energy. Some electrode half-equations and their standard electrode potentials are shown

More information

1.11 Redox Equilibria

1.11 Redox Equilibria 1.11 Redox Equilibria Electrochemical cells Electron flow A cell has two half cells. The two half cells have to be connected with a salt bridge. Simple half cells will consist of a metal (acts an electrode)

More information

Automatic titrators, TitroMatic

Automatic titrators, TitroMatic 112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator

More information