1 Liquid chromatography and tandem mass spectrometry: a powerful approach for the sensitive and rapid multiclass determination of pesticides and transformation products in water Juan V. Sancho, Oscar J. Pozo and Félix Hernández* Analytical Chemistry, Experimental Sciences Dept., University Jaume I, P.O. Box 224, E Castellón, Spain. hernandf@exp.uji.es; Fax: ; Tel: Received 2nd October 2003, Accepted 1st December 2003 First published as an Advance Article on the web 11th December 2003 In this paper we will show the results of our research on the direct simultaneous determination of multi-class pesticides and transformation products with different polarities and acid base properties by applying an on-line trace enrichment coupled to the chromatographic system supplied with electrospray interface (SPE-LC-MS/MS method). The specific chromatographic separation allows the correct determination of almost fifty compounds (37 pesticides and 10 transformation products) using very low sample volume and very little sample handling. Recoveries between % were obtained for all compounds in drinking and groundwater, meanwhile in surface water 44 compounds were correctly quantified. Relative standard deviations lower than 15% were obtained for all compounds. Even at the lowest concentration level tested (25 ng L 21 ) 40 compounds presented satisfactory recoveries and repeatability. The use of methanol as organic modifier and the increase of injection volume are also studied. The applicability of the developed method to a monitoring programme is demonstrated by applying it to the analysis of hundreds of samples. DOI: /b312236K Introduction Recent years have witnessed the growing use of pesticides, chiefly in agriculture, but also in public works (road and rail maintenance) and home products. 1 This development has undeniable repercussions on the environment, and the quality control of natural waters, both groundwater and surface water, has become a major issue. To address the subject, several national and international regulations now exist, including the European regulation on drinking water quality, which sets a maximum concentration of 0.1 mg L 21 for an individual pesticide and 0.5 mg L 21 for total pesticides present in the sample. The variety of substances determined and their degradation products entail the use of wide-spectrum, reliable and sensitive multi-residue methods to produce analysis to meet the regulations. The potential of liquid chromatography coupled with mass spectrometry (LC-MS) for the determination of pesticide residues in water samples was recognized early. 2 Since then LC-MS has became an alternative to the common gas chromatography-mass spectrometry (GC-MS) methods in this area. 3 4 Sample pretreatment is normally more tedious by using GC-MS, besides most pesticide residues found in ground and surface waters tend to be polar compounds and/or transformation products (TPs) of the parent compounds applied. 5 Therefore, LC-MS is becoming even more attractive in this type of analysis. In the last years, due to the introduction of ion-trap mass spectrometers and because triple quadrupoles became commercially available, applications in the determination of pesticide residues in water samples by using tandem mass spectrometry have drastically increased. 6 With these instruments the method selectivity has been notably increased due to the inherent selectivity of the technique. Furthermore, detection limits are decreased by using selected reaction monitoring (SRM) instead of selected ion monitoring (SIM) simplifying in this way sample pre-treatment and minimizing analytical errors associated to sample handling. Although some papers described the use of quadrupole instruments in order to identify unknown pesticides, 7 most of the Electronic supplementary information (ESI) available: Method validation data. See developed methods with these instruments consist of the determination of a limited number of compounds. Thus, LC-MS methods for the determination of phenylureas, 8,9 phenolic and acidic herbicides, 10 chlorinated compounds 11 or imidazolinone herbicides 12 have been described and some organophosphorus, 13 phenylureas, 14 triazines 14 and quaternary ammonium pesticides 15 have been determined by LC-MS/MS methods. Normally these methods involved a screening of preselected compounds as only one transition for each was used in order to determine the analyte. Although sometimes it is difficult to obtain more than one transition for one compound due to the soft ionisation in API interfaces, the main reason for the choice of screening instead confirmatory methods has been the loss of sensitivity when more transitions are added. For quadrupole instruments an interrelationship exists between the sensitivity of detection and the time spent recording one transition. 16 A high sensitivity requires long collection time for each ion to be detected, and this time decreases when more transitions are recorded at the same time. Therefore, the higher the number of compounds, the lower the collection time and the lower the sensitivity of the method. On the other hand, a different problem appears in the use of LC- MS/MS for quantitative purposes. The presence of matrix coeluting organic compounds can interfere with the ionisation of the target analyte severely affecting the quantification. 17 Although this matrix effect could be compensated by using labelled isotope standards or by using matrix-matched calibration, both solutions are not suitable in the environmental analysis as it is difficult to obtain commercially available isotope labelled standards for all analytes, and normally the use of only one internal standard in order to correct several compounds does not generate satisfactory results. 18 Furthermore, the variability of the matrix between series of samples misadvises the matrix-matched calibration. A suitable clean-up step is usually performed in order to reduce this matrix effect. The use of off-line mode or on-line trace enrichment by solid-phase extraction 7 9,19,20 (SPE-LC) is the most common approach for sample pre-treatment in the environmental field although some papers described liquid liquid extraction 7 or dual precolumn extraction. 21 Obviously, this clean-up step is also used to concentrate the sample, however coeluting matrix interferences are usually concentrated and, although sensitivity is improved, the 38 Analyst, 2004, 129, This journal is The Royal Society of Chemistry 2004

2 matrix effect is not reduced. 7,19,22 This problem can be solved by reducing the sample volume 23 or by improving the chromatographic separation using LC-LC coupling. 24 All considerations indicated above have to be kept in mind when developing realistic methods to be applied at the sub-ppb concentration levels. This paper describes a rapid method for the determination of 47 selected pesticides and transformation products in water. The method, based on SPE in combination with LC and tandem mass spectrometry, employs only 1.3 ml of sample and reaches detection limits lower than 100 ng L 21 for all analytes, as recommended by the European guideline for drinking water. The method has been validated and implemented for routine analysis of surface and groundwater samples in the Mediterranean coast of Spain. Experimental Reagents and chemicals Pesticides and transformation products were chosen on the basis of information available on pesticides used in citrus production, which is the most important crop in our area (Western Mediterranean Coast of Spain), and considering the commercial availability of standards as well (mainly for TPs). Pesticides and metabolite reference standards were purchased from Dr Ehrenstorfer (Augsburg, Germany), Riedel de Haën (Seelze, Germany) and Sigma (St. Louis, MO, USA). HPLC grade acetonitrile and methanol were purchased from ScharLab (Barcelona, Spain). LC grade water was obtained by purifying demineralized water in a Nanopure II system (Barnstead, Newton, MA, USA). Formic acid (HCOOH, content > 98%) were supplied by Fluka (Buchs, Switzerland). Stock standard solutions were prepared dissolving 25 mg, accurately weighted, in 50 ml of HPLC grade acetonitrile obtaining a final concentration of 500 mg ml 21. For LC-MS analysis, the stock solutions were mixed and diluted with acetonitrile or HPLC grade water. Liquid chromatography A triple quadrupole mass spectrometer was interfaced to an HPLC system based on a 233XL autosampler with a loop of 1330 ml (Gilson, Villiers-le-Bel, France) and 2 pumps: an Agilent 1100 (Agilent, Waldbron, Germany) binary pump used to condition and wash the cartridge (P-1) and a Waters Alliance 2690 (Waters, Milford, MA, USA) quaternary pump used for the chromatographic separation (P-2). The experimental setup can be found elsewhere. 23 The SPE preconcentration was performed with a polymeric phase Hamilton PRP-1 using a small cartridge, mm (Teknokroma, Barcelona, Spain) as C-1. For the LC separation a column mm packed with Nucleosil C18 5 mm from ScharLab was used as C-2. Mobile phases consisted in water and acetonitrile in P-1 and mixtures of 0.01% HCOOH in acetonitrile 0.01% HCOOH in water in P-2. Mass spectrometry A Quattro LC (quadrupole-hexapole-quadrupole) mass spectrometer with an orthogonal Z-spray-electrospray interface (Micromass, Manchester, UK) was used. Drying gas as well as nebulising gas was nitrogen generated from pressurized air in a NG-7 nitrogen generator (Aquilo, Etten-Leur, NL). The nebuliser gas flow was set to approximately 80 L h 21 and the desolvation gas flow to L h 21. Infusion experiments were performed using a Model 11 single syringe pump (Harvard Instruments, Holliston, MA, USA), directly connected to the interface. For operation in MS/MS mode, collision gas was Argon % (Carburos Metalicos, Valencia, Spain) with a pressure of mbar in the collision cell. Capillary voltages of 23 kv and 3.5 kv were used in negative and positive ionization mode respectively. The interface temperature was set to 350 C and the source temperature to 120 C. Dwell times of 0.1 s scan 21 were chosen. Masslynx NT v 3.4 (Micromass, Manchester, UK) software was used to process the quantitative data obtained from calibration standards and from water samples. Recommended procedure Water samples were centrifuged at 3500 rpm for 10 min (only in the case of suspended particulate matter) and acidified with formic acid at 1%. This acidified sample was loaded in the loop and directly injected into the SPE-LC-(ESI)-MS/MS system. The conditioning of the PRP-1 cartridge was achieved with acetonitrile at a flow rate of 2 ml min 21 for 2 min, following by 2 min more with water. An aliquot of the acidified water sample (1330 ml) was preconcentrated into the cartridge and washed with 4 ml of water at 2 ml min 21. After been washed, the sample was transferred in backflush mode to the C-2 column and a gradient in P-2 started. 23 Pesticide standard solutions used for quantification were also preconcentrated by SPE using the same procedure as for samples. To perform the chromatographic separation a 0.01% HCOOH in acetonitrile:0.01% HCOOH in water gradient was optimised. The percentage of organic modifier was changed linearly as follows: 0 min, 5%; 6 min, 70%; 9 min, 70%; 10 min, 90%; 14 min, 90%; 15 min, 5%, 18 min 5% at a flow rate of 0.3 ml min 21 Finally, the determination was carried out by MS/MS under optimised conditions that are shown in Table 1. Validation study The precision (expressed as relative standard deviation, in %) was evaluated within-day by determining all pesticides in three standard solutions prepared at 25, 100 and 500 ng L 21 (n = 8 for each concentration level). The calibration curve was obtained by analysing standard solutions in triplicate at eight concentrations between 0 and 500 ng L 21. The recoveries were obtained by analysing drinking, ground and surface water samples spiked at three concentration levels each (25, 100 and 500 ng L 21 ). These experiments were performed in quintuplicate (n = 5). The limit of quantification (LOQ) was taken as the lowest concentration level validated, for which adequate recoveries (between 70 and 120%) and precisions (RSD < 15%) were obtained. The limit of detection (LOD), defined as the lowest concentration that the analytical process can reliably differentiate from background levels, was estimated when the signal was three times the background noise from the chromatograms at the lowest analyte concentration assayed. Results and discussion MS optimisation The full-scan mass spectra and the MS/MS spectra were obtained from infusion of 5 mg ml 21 50:50 acetonitrile:water solutions of each compound at a flow rate of 10 ml min 21. The multi-class nature of the selected pesticides as well as their different acid base properties made that 10 out of 47 compounds presented only negative ionisation meanwhile the rest showed preferably positive ionisation. Most of compounds presented a [M + H] + or [M 2 H] 2 ion, which led to a main product ion by fragmentation in the collision cell. However, carbofuran-7-phenol-3-keto (N = 10, see Table 1), trichloropirydinol (TCPY) (N = 16) and fomesafen (N = 29) showed MS/MS spectra without any important fragment. In these cases, the measured fragment ion was the selected precursor ion, but using a collision energy high enough for breaking interferences in the collision cell without affecting to an important degree sensitivity; therefore cleaner chromatograms were obtained. 25 As Analyst, 2004, 129,

3 an example, for the determination of carbofuran-7-phenol-3-keto (N = 10) case, both the precursor ion and product ion were selected at m/z 177, and a collision energy of 15 ev was set in order to break interferences preserving this molecule. Moreover, azinphos-methyl (N = 28) was not measured by fragmentation of its protonated molecule [M + H] + ion of m/z 318. A more sensitive transition was obtained under in-source fragmentation, as azinphos-methyl undergoes entrance-cone fragmentation and produces a fragment at m/z 160 which generates a product ion at m/z 132 in the collision cell. The mass spectrometry parameters selected, as precursor and product ions, cone voltage and collision cell energy, for selected compounds are shown in Table 1. LC optimization The preconcentration cartridge selected was filled with polymeric material rather than C18-modified silica in order to increase the retention for the most polar transformation products and pesticides. 4 ml of water was selected as washing volume as it is shown elsewhere. 23 Moreover, the number of pesticides and transformation products has been increased in relation to our previous work, including mainly acidic analytes. This fact implies a previous acidification of the water sample before on-line trace enrichment as well as the use of different analytical column as the polar embedded stationary phase used before 23 did not produce acceptable chromatographic peaks for acidic pesticides. The water sample was acidified with formic acid up to 1% and a standard reversed phase microbore separation column was used instead of the Supelco ABZ+ column. Another result of including acidic analytes is that mobile phase has to be also acidified. Acidic analytes are detected under electrospray process as deprotonated molecules in negative mode. Thus, the acidification of mobile phase leads to a decrease in the MS sensitivity due to the ionisation suppression. On the other hand, acidified mobile phase allowed us to enhance the sensitivity for the compounds analysed in positive electrospray mode. Therefore, a compromise between correct chromatographic peaks and sensitiv- Table 1 MS conditions and chromatography behaviour for all selected compounds Compound N a Polarity Precursor ion (m/ z) Cone/V Collision/eV Product ion (m/z) Group Oxamyl 1 ES A Methomyl 2 ES A 2-Aminobenzimidazol b 3 ES A DIA bc 4 ES A 6-Chloronicotinic acid b 5 ES A Carbendazim 6 ES A Carbofuran-3-OH bd 7 ES A Imidacloprid 8 ES A Dimethoate 9 ES A Carbofuran-7-phenol-3-keto b 10 ES A Bromacil 11 ES B Pyrimicarbe 12 ES B Fluroxypyr 13 ES B Terbacil 14 ES B 4-Chloroaniline b 15 ES B TCPY be 16 ES B Simazine 17 ES B 3-Methyl-p-nitrophenol b 18 ES B Carbofuran b 19 ES B MCPA f 20 ES B Ethiofencarb 21 ES B Diuron 22 ES B 3,4-Dichloroaniline b 23 ES B Fluazifop 24 ES B Methiocarb 25 ES B Methidathion 26 ES C Terbuthylazine 27 ES C Azinphos-methyl 28 ES C Fomesafen 29 ES C Pyridaphenthion 30 ES C Molinate 31 ES C Malathion 32 ES C Terbumeton 33 ES C Mecarbam 34 ES C Quinalphos 35 ES C Terbutryne 36 ES C Diazinon 37 ES C Thiobencarb 38 ES D Chlorpyrifos-methyl 39 ES D Pirimiphos-methyl 40 ES D Tebufenpyrad 41 ES D Pyriproxyfen 42 ES D Hexythiazox 43 ES D Chlorpyrifos 44 ES D Pendimethalin 45 ES D Buprofezin 46 ES D Pyridaben 47 ES D a N: Peak number. b Transformation products. c DIA: Desisopropylatrazine. d Carbofuran 3-OH: 3-hydroxy-carbofuran. e TCPY: 2,4,6-trichloro-3-pyridinol. f MCPA: 2-methyl-4-chlorophenoxyacetic acid. 40 Analyst, 2004, 129, 38 44

4 ity should be appraised by optimising the content of formic acid in the mobile phase. A 0.01% formic acid in both water and acetonitrile was finally selected and a gradient was optimised to perform the group separation. Optimised gradient is shown in experimental section. The chromatographic separation between groups of analytes is required in order to ensure enough points for defining the chromatographic peak, as detection is performed sequentially. The smaller the group, the higher the number of points available for defining the peak, thus improving the quality of data. Under optimised conditions, chromatographic groups of less than 16 compounds that eluted in the same group (16 transitions) were obtained and good peak shapes were achieved for all compounds. These chromatographic groups are shown in Table 1. The total chromatographic run was only 14 min for 47 analytes, ranging from very polar transformation products as 2-aminobenzimidazol (N = 3) to nonpolar pesticides as pyridaben (N = 47), and the overall analytical process, including the on-line trace enrichment was around 27 min. However, the LC-MS equipment used allowed us to overlap the cartridge conditioning and the next sample loading with the chromatographic separation of the current sample rendering a real analysis time per sample of only 18 min. In this work, we only selected one transition for both quantitation and qualification as the use of another transition for confirmation implied the use of at least 94 channels. This high number of channels would require longer chromatographic runs in order to increase the data points available per peak, decreasing the sample throughput of the developed procedure. As our main objectives were multi-residuality and short run-time period, we kept only one channel per analyte. Moreover, for some analytes is difficult to find more product ions in the spectra that can be used for confirmation. Analytical characteristics Standard curves showed excellent linearity, with correlation coefficients greater than for all the 47 compounds in the range from 0 to 1000 ng L 21. The linear range was lower in few cases as 2-aminobenzimidazol (N = 3) where a quadratic curve was applied. The method showed good precision (RSD < 15%) for all compounds with very few exceptions, the most notable being diazinon (N = 37) with a RSD up to 27%. Even at a concentration as low as 25 ng L 21, 39 out of 47 compounds still presented good repeatability. Limits of detection (LOD) were calculated from the most diluted standard analysed and ranged from ng L 21 for some compounds like carbendazim (N = 6), carbofuran (N = 19) and pyrimicarb (N = 12) to around 50 ng L 21 for other as chlorpyrifos (N = 44), tebufenpyrad (N = 41) and hexythiazox (N = 43), the poorest values being for pyridaben (N = 47) (LOD 210 ng L 21 ). For 33 out of 47 compounds the LOD were lower than 10 ng L 21, using as low as 1.3 ml of sample, and only 7 compounds presented detection limits above 25 ng L 21, the LOD objective in this work. The majority of these 7 compounds were late eluting analytes. In order to improve this situation two alternatives were tested: the use of a ternary acetonitrile/methanol/water gradient or the increase of sample volume to be preconcentrated in the PRP-1 cartridge. As regards the use of methanol in the mobile phase, some improvement in the sensitivity by using this organic modifier has been described. 18,26 However, methanol is not strong enough to desorb the analytes from the polymeric cartridge, 18 therefore a ternary gradient was used. The gradient started with a mixture acetonitrile/water and after 6 min the mobile phase was changed to methanol/water so late-eluting analytes entered the electrospray interface together with a more protic solvent as methanol that may enhance the signal in positive mode. This effect was found to be compound-dependent and varied from no effect to two-three fold signal increase. Anyway, the signal improvement did not allow reaching detection limits below 25 ng L 21 for several of the lateeluting analytes. The effect of increasing the sample volume to be preconcentrated on the polymeric cartridge was also investigated. Keeping in mind a short overall analysis time and considering the presence of very polar metabolites within the group of selected analytes, the loop size was increased from 1.3 ml up to only 4.4 ml, in spite of the fact that a polymeric cartridge was employed. Using an acetonitrile/ water gradient and the same loading scheme, the sensitivity was increased enough for the late-eluting analytes, achieving limits of detection below 25 ng L 21 for all the 47 studied compounds. However, sample breakthrough started to occur for early-eluting analytes, and similar or even worse limits of detection were obtained for some polar pesticides and metabolites, although LOD were in all cases below 25 ng L 21. Recoveries were satisfactory for all compounds in drinking and groundwater matrices showing the non existence of matrix effect. However, in the surface water tested the higher amount of interferences preconcentrated on the polymeric cartridge produced signal suppression in the electrospray source for some analytes, leading to recoveries below 70%, or signal enhancement in others giving recovery values above 120%. Consequently, the method was not modified, and 1.3 ml of sample with an acetonitrile: water gradient were used for the sample analysis. Method validation Precision and accuracy of the overall analytical procedure were evaluated for surface, ground and drinking water samples spiked at 25, 100 and 500 ng L 21 level. The high number of data (3 matrices at 3 concentration levels and 47 analytes) makes difficult their presentation in a table as a whole (see Electronic supplementary information (ESI)). The method was found to be precise (RSD < 15%) for all the compounds studied at 100 and 500 ng L 21 spiking level. Besides, recoveries were satisfactory (between 70% and 120%) in drinking and groundwater for all analytes. As regards surface water, the presence of more interferences resulted in lower recoveries (60 70%) for only three compounds (methomyl (N = 2), oxamyl (N = 1) and the metabolite 6-chloronicotinic acid (N = 5)), although with satisfactory precision (RSD < 15%). At the 25 ng L 21 spiking level, 40 compounds could still be satisfactorily quantified, and only three analytes (imidacloprid (N = 8), 4-chloroaniline (N = 15) and TCPY (N = 16)) presented unacceptable precision with RSD > 15%. All average recoveries at this low concentration level in the three water matrices tested were in the % range. The method could not be validated at 25 ng L 21 for three insecticides (pyriproxyfen (N = 42), chlorpyrifos methyl (N = 39) and chlorpyrifos (N = 44)), 3 acaricides (tebufenpyrad (N = 41), hexythiazox (N = 43) and pyridaben (N = 47)) and 1 TP (carbofuran-7-phenol-3-keto (N = 10)), but all of them (except for pyridaben (N = 47)) were determined satisfactorily at the 100 ng L 21 level. In conclusion, the majority of pesticides and metabolites could be satisfactorily determined at sub-ppb levels in drinking, ground and surface water using only 1.3 ml of sample. The poorest results were obtained for pyridaben, as it was the last analyte eluting at the end of the gradient, surely co-eluting with interferent compounds that would suppress its ionisation. In the developed method the different matrix components of surface water in relation to drinking and groundwater seemed to not affect robustness, as only 1.3 ml of sample were preconcentrated. As an example, Fig. 1 shows representative chromatograms for groundwater spiked at 25 ng L 21. The method developed in this paper presents some advantages over those previously reported. The most important one is the low injection volume used which is around 10 times lower than previously reported methods, this reduction allows the correct Analyst, 2004, 129,

5 quantification of almost all the analytes at the regulatory level by using electrospray interface without any matrix effect observed. This result can be compared with other methods where the high amount of matrix introduced in the source generated poor recoveries for some compounds, 19,21,22 as it was also observed in this paper when increasing the sample volume for surface waters. On the other hand, this small volume allows the easy automatisation of the analysis and reduces considerably the total run time, as one of the most time consuming tasks in the determination of pesticide residues in water is the preconcentration step. Monitoring of pesticides in environmental waters More than 100 samples of ground and surface water were collected in selected sites from Spanish Mediterranean area (Castellon, Valencia, Alicante and Murcia provinces). This is an important citrus-growing area, where many pesticides from different chemical families are applied, mainly insecticides and herbicides. Several horticultural crops are also frequent, and additionally exists an important area for rice crop, which the most representative site is the Albufera Lagoon of Valencia. After collection of samples, they were transported to the laboratory and stored at 218 C until required for residue analysis. Several pesticides and metabolites were detected at relatively high concentrations (mg L 21 level) in both ground and surface water. 27 The high sensitivity as well as the multiresiduality of the method applied allowed us to detect a variety of pesticides and TP at very low levels. As an example, Fig. 2 shows chromatograms for groundwater samples containing several pesticides at the sub-ppb level. Some of the areas monitored presented severe pollution by pesticides in surface water. As an example, in a surface water from a wetland surrounded by citrus orchards sited at Burriana fourteen compounds were detected, in several cases at concentrations higher than 1 mg L 21 (Fig. 3). Fig. 1 SPE-LC-ESI-MS/MS chromatograms from a groundwater sample (A) blank. (B) spiked at 25 ng L 21 and (C) 25 ng L 21 standards of dimethoate (N = 9), MCPA (N = 20) and pyridaphenthion (N = 30). Fig. 2 Typical SPE-LC-ESI-MS/MS chromatograms from positive real groundwater samples. (A) sample containing 0.47 mg L 21 of terbuthylazine (N = 27) and 0.13 mg L 21 of terbacil (N = 14). (B) sample containing 0.11 mg L 21 of diuron (N = 22) and 2.5 mg L 21 of bromacil (N = 11). (C) sample containing 0.04 mg L 21 of methomyl (N = 2) and 0.12 mg L 21 of DIA (N = 4). 42 Analyst, 2004, 129, 38 44

6 Fig. 3 SPE-LC-ESI-MS/MS chromatogram from a surface water sample collected from the Clot de la Mare de Deu in Burriana containing 0.70 mg L 21 of diuron (N = 22), 3.96 mg L 21 of MCPA (N = 20), 0.13 mg L 21 of terbacil (N = 14), mg L 21 of terbumeton (N = 33), 0.05mg L 21 of methomyl (N = 2), 1.33 mg L 21 of DIA (N = 4), 4.10 mg L 21 of simazine (N = 17), 1.89 mg L 21 of terbutryne (N = 36), 0.37 mg L 21 of terbuthylazine (N = 27), 0.07 mg L 21 of bromacil (N = 11), 0.11 mg L 21 of fluroxypyr (N = 13), 0.26 mg L 21 of carbofuran (N = 19), 0.17 mg L 21 of 2-aminobenzimidazol (N = 3) and 0.81 mg L 21 of carbendazim (N = 6). For several compounds, the good peak obtained (i.e. terbumeton, N = 33) allowed us the quantification of the analyte at concentrations lower than 25 ng L 21 (the LOQ of the method), although the method was not validated at such a low levels. For example, a concentration of ca. 10 ng L 21 was estimated for terbumeton from the chromatogram shown in Fig. 3. Summarising, herbicides were the most commonly detected pesticides in groundwater. Triazines were found in around 79% of samples, as an example, 15% of samples contained more than 0.1 mg L 21 of terbuthylazine. Other herbicides as bromacil, terbacil and diuron were detected in around 54% of groundwater samples (e.g. 34% of samples contained more than 0.1 mg L 21 of bromacil). Molinate was also frequently detected. In relation to insecticides, pyrimicarb, carbofuran and ethiofencarb were detected in around 25% of samples (always below 0.1 mg L 21 ). None of the acaricides investigated were detected in the groundwater samples. However, the fungicide carbendazim was largely detected (51%) in the samples. As regards transformation products, 2-aminobenzimadol and carbofuran were the most commonly detected in the samples. Regarding surface water samples, herbicides were again the most frequently detected, their concentrations levels being notably higher than in groundwater. As an example, 36% of surface waters presented concentrations of triazines higher than 0.1 mg L 21 with a mean of 1.7 mg L 21 and a maximum of 7 mg L 21. Moreover, organophosphorous pesticides were often detected, and 34% of samples contained methidathion, chlorpyrifos or dimethoathe. The robustness of the method was proved by more than 4 months of performing the analysis of surface and groundwater samples. Some variations in the sensitivity of the instrument were occasionally observed, making the quantification at the lowest validated level (0.025 mg L 21 ) difficult for some compounds, although no relevant problems were observed at the 0.1 mg L 21 concentration level. In these situations, a simple cleaning of the Z-Spray source was enough to recover sensitivity up to satisfactory levels. Conclusion The developed procedure allows the simultaneous determination of 37 pesticides and 10 transformation products with different polarities and acid base properties in drinking, ground and surface water with a global analysis time of 18 min (sample throughput of ca. 80 samples day 21 ) using only 1.3 ml of sample. All compounds are correctly quantified at the 0.1 mg L 21 concentration level, which is the restrictive regulatory level for drinking water in the E.U. Besides, most of them (40 out of 47) can also be correctly quantified at 25 ng L 21. Detection limits are for most compounds (33 out of 47) even lower than 10 ng L 21. Satisfactory precision and recoveries are obtained and sample preparation is minimal, rendering a fast and robust assay. The high automation of the method as well as the reduced sample pre-treatment make affordable an easy confirmation of the positive samples by reanalysing them using a confirmatory transition, wherever available. In order to optimise the selection of transformation products to be included in future analytical methods, the degradation of the most used pesticides in our area is being studied in our laboratory by using a hybrid quadrupole-time of flight (QTOF) instrument, with exact mass capabilities, in combination with dedicated software tools, as Metabolynx. Acknowledgements The authors are very grateful to the Serveis Centrals d Instrumentació Científica (SCIC) of University Jaume I for the use of the Quattro LC triple quadruple mass spectrometer. This work is included within the research project (ref: REN ) developed under financial support of the Ministerio de Ciencia y Tecnología, Spain. References 1 V. Pignon, R. Jeannot and E. Sauvard, Int. J. Environ. Anal. Chem., 1999, 75(4), R. D. Voyksner and C. A. Haney, Anal. Chem., 1985, 57, W. M. A. Niessen, J. Chromatogr., A, 1999, 856, R. B. Geerdink, W. M. A. Niessen and U. A. Th. Brinkman, J. Chromatogr., A, 2002, 970, D. W. Kolpin, E. M. Thurman and S. M. Linhart, Sci. Total Environ., 2000, 248, T. Reemtsma, Trends Anal. Chem., 2001, 20, H. Sabik and R. Jeannot, J. Chromatogr., A, 1998, 818, Di Corcia, A. Costantino, C. Crescezi and R. Samperi, J. Chromatogr., A, 1999, 852, E. Baltussen, H. Snijders, H. G. Janssen, P. Sandra and C. A. Cramers, J. Chromatogr., A, 1998, 802, Analyst, 2004, 129,

7 10 A. C. Hogenboom, I. Jagt, R. J. J. Vreuls and U. A. Th. Brinkman, Analyst, 1997, 122, A. J. H. Louter, A. C. Hogenboom, J. Slobodnik, R. J. J. Vreuls and U. A. Th. Brinkman, Analyst, 1997, 122, G. D Ascenzo, A. Gentili, S. Marchese and D. Perret, J. Chromatogr., A, 1998, 800, A. Ingelse, R. C. J. van Dam, R. J. Vreeken, H. G. J. Mol and O. M. Steujger, J. Chromatogr., A, 2001, 918, C. Hogenboom, W. M. A. Niessen and U. A. Th. Brinkman, J. Chromatogr. A, 1998, 794, R. Castro, E. Moyano and M. T. Galceran, J. Chromatogr., A, 2001, 914, T. Reemtsma, Trends Anal. Chem., 2001, 20, K. Matuszewski, M. L. Constanzer and C. M. Chavez-Eng, Anal. Chem., 1998, 70, P. G. M. Kienhuis and R. B. Geerdink, Trends Anal. Chem., 2000, 19, Koppen and N. H. Spliid, J. Chromatogr., A., 1998, 803, R. Curini, A. Gentili, S. Marchese, A. Marino and D. Perret, J. Chromatogr., A, 2000, 874, R. J. C. A. Steen, A. C. Hogenboom, P. E. G. Leonards, R. A. L. Peerboom, W. P. Cofino and U. A. Th. Brinkman, J. Chromatogr., A, 1999, 857, A. C. Hogenboom, M. P. Hofman, D. A. Jolly, W. M. A. Niessen and U. A. Th. Brinkman, J. Chromatogr., A, 2000, 885, F. Hernández, J. V. Sancho, O. Pozo, A. Lara and E. Pitarch, J. Chromatogr. A, 2001, 939, E. Dijkman, D. Mooibroek, R. Hoogerbrugge, E. Hogendoorn, J. V. Sancho, O. Pozo and F. Hernandez., J. Chromatogr., A, 2001, 926, J. V. Sancho, O. Pozo and F. Hernández, Rapid Commun. Mass Spectrom., 2000, 14, R. B. Geerdink, A. Kooistra-Sijpersma, J. Tiesnitsch, P. G. M. Kienhuis and U. A. Th. Brinkman, J. Chromatogr., A, 1999, 863, I. Morell, R. Aragón, J. L. García, O. Pozo, S. Grimalt, J. V. Sancho and F. Hernández, Environ. Sci. Technol., submitted. 44 Analyst, 2004, 129, 38 44

Trends Trends in Analytical Chemistry, Vol. 24, No. 7, 2005

Trends Trends in Analytical Chemistry, Vol. 24, No. 7, 2005 Trends Trends in Analytical Chemistry, Vol. 24, No. 7, 25 Strategies for quantification and confirmation of multi-class polar pesticides and transformation products in water by LC MS 2 using triple quadrupole

More information

Application of ultra performance liquid chromatography tandem mass spectrometry to the analysis of priority pesticides in groundwater

Application of ultra performance liquid chromatography tandem mass spectrometry to the analysis of priority pesticides in groundwater Journal of Chromatography A, 1109 (2006) 222 227 Application of ultra performance liquid chromatography tandem mass spectrometry to the analysis of priority pesticides in groundwater Milagros Mezcua a,

More information

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Application Note Clinical Research Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Authors Yanan Yang 1, Victor Mandragon 2, and Peter Stone 1 1

More information

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Application Note Food Authors Jianqiu Mi, Zhengxiang Zhang, Zhixu Zhang,

More information

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS Application Note Food Testing and Agriculture Author Chen-Hao (Andy) Zhai and Rong-jie Fu Agilent Technologies (Shanghai)

More information

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Application Note EPA Method 535 EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS API 3200 LC/MS/MS System Overview Described here is the

More information

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish. 1 Supporting Information 2 3 Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish. 4 5 John Moreman, Okhyun

More information

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Christopher Borton AB SCIEX Golden, Colorado verview Described here is the analysis of

More information

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer 38 Current Trends in Mass Spectrometry November 6 Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer This article demonstrates the improved

More information

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Chemistry Instrumental Analysis Lecture 37. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 37 Most analytes separated by HPLC are thermally stable and non-volatile (liquids) (unlike in GC) so not ionized easily by EI or CI techniques. MS must be at

More information

A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS

A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS [ application note ] A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS Patricia Revilla-Ruiz 1, Gordon Kearney 2,

More information

Supporting Information

Supporting Information 1 Supporting Information 2 3 Discovery and implications of C 2 and C 3 perfluoroalkyl sulfonates in aqueous film forming foams (AFFF) and groundwater 4 Krista A. Barzen-Hanson a and Jennifer A. Field b*

More information

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery Application Note: 3 Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery Yoko Yamagishi, Thermo Fisher Scientific, C-2F 3-9

More information

Ultra-fast screening of pesticides in foods and agricultural products with desorption corona beam ionization (DCBI) tandem mass spectrometry

Ultra-fast screening of pesticides in foods and agricultural products with desorption corona beam ionization (DCBI) tandem mass spectrometry PO-CON18E Ultra-fast screening of pesticides in foods and agricultural products with desorption corona beam ionization (DCBI) ASMS 21 TP 3 Jing Dong, Satoshi Yamaki, Yuki Hashi, Naoki Hamada Shimadzu China,

More information

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS Application Note: 56 Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS Yang Shi, Catherine Lafontaine, Matthew Berube, John Fink, François Espourteille Thermo

More information

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis PO-CON1768E Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide ASMS 2017 TP-194 David Baker 1, Christopher Titman 1, Neil Loftus 1, Jonathan Horner

More information

Multi-residue analysis of pesticides by GC-HRMS

Multi-residue analysis of pesticides by GC-HRMS An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict

More information

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539) Determination of ormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell P Column (EPA 539) Application Note Environmental Authors Rong-jie Fu and Chen-ao (Andy) Zhai Agilent Technologies

More information

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION Quantitation by High Resolution Mass Spectrometry: Using Target Enhancement and Tof-MRM to Achieve Femtogram-level On-column Sensitivity for Quantitation of Drugs in Human Plasma Yun W. Alelyunas, Mark

More information

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode Application Note Authors Siji Joseph Agilent Technologies India Pvt. Ltd.

More information

Yokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan.

Yokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan. Determination of organochlorine pesticides in river water by gas chromatography-negative-ion chemical-ionization mass spectrometry using large volume injection Sadao Nakamura,* Takashi Yamagami and Shigeki

More information

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS Application Note Drug Discovery Authors Srividya Kailasam Agilent

More information

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis LC/Q-TO Workflows for Comprehensive Micropollutant Analysis Targeted Quantification, Suspect Screening, and Unknown Compound Identification Application Note Environmental Authors Christoph Moschet and

More information

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core

More information

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany Analysis of Pesticides by Supercritical Fluid Chromatography/ Mass Spectrometry Optimizing the Agilent 126 Infi nity Analytical SFC System in Combination with the Agilent 646 Triple Quadrupole LC/MS Application

More information

Application Note. Abstract. Authors. Environmental

Application Note. Abstract. Authors. Environmental Determination of Acidic Herbicides using an Agilent 6460 Triple Quadrupole LC/MS Equipped with Agilent Jet Stream Technology and Direct Aqueous Injection, for Potable and Environmental Samples Application

More information

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 129 Infi nity LC, and 646 Triple Quadrupole LC/MS Application Note Clinical Research Authors Linda Côté and Christophe

More information

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS Application ote Food Testing & Agriculture Author Andy Zhai Agilent Technologies, Inc. Shanghai Co. Ltd.

More information

DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS

DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS Peter Hancock 1, Cristiana C. Leandro 2,3, Brendan J. Keely 2 and Richard J. Fussell 3 1 Waters Corporation,

More information

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry Application Note Doping Control Authors Prof. Maria Kristina Parr Freie Universität Berlin Institute

More information

Multiresidue Analysis of 100 Pesticides in Food Samples by LC/Triple Quadrupole Mass Spectrometry Application

Multiresidue Analysis of 100 Pesticides in Food Samples by LC/Triple Quadrupole Mass Spectrometry Application Multiresidue Analysis of Pesticides in Food Samples by LC/Triple Quadrupole Mass Spectrometry Application Food Safety Authors Imma Ferrer and E. Michael Thurman Pesticide Residue Research Group University

More information

16 Malachite green 17 Leucomalachite green

16 Malachite green 17 Leucomalachite green 16 17 Leucomalachite green hydrochloride Leucomalachite green N N N + Cl - N N-[4-[[4-(dimethylamino)-phenyl] phenylmethylene]-2,5-cyclohexadien-1-ylidene ]-N-methylmethanaminium chloride C 23 H 25 ClN

More information

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Application Note Authors Kevin McCann, Sameer Nene, Doug McIntyre, Edmond Neo, Dennis Nagtalon, and

More information

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK Multi-residue GC-MS analysis Richard Fussell CSL York, UK e-mail: r.fussell@csl.gov.uk Outline of Presentation Background Gas Chromatography Mass Spectrometry - Options Capabilities and Applications Summary

More information

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis Abstract A rapid, targeted quantitative UHPLC-triple quadrupole

More information

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS Application Note Food Authors Gerd Vanhoenacker, Frank David,

More information

Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS

Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS PO-CON1745E Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS ASMS 2017 MP 189 Shailendra Rane 1, Ashutosh Shelar 1, Shailesh Damale 1, Rashi Kochhar 1, Purshottam Sutar 1,

More information

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma Jon Bardsley 1, James Goldberg 2 1 Thermo Fisher Scientific, Runcorn, UK; 2 Thermo Fisher Scientific, West Palm Beach,

More information

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis Application Note AN772 Introduction This application note describes the extraction of cocaine and a full range

More information

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction Determination of Pesticide Residues in Oats by Automated QuEChERS and LC/QQQ Application Note Abstract The QuEChERS (Quick-Easy-Cheap-Effective-Rugged-Safe) sample extraction method was developed for the

More information

Comparison of liquid chromatography using triple quadrupole and quadrupole ion trap mass analyzers to determine pesticide residues in oranges

Comparison of liquid chromatography using triple quadrupole and quadrupole ion trap mass analyzers to determine pesticide residues in oranges Journal of Chromatography A, 1067 (2005) 115 125 Comparison of liquid chromatography using triple quadrupole and quadrupole ion trap mass analyzers to determine pesticide residues in oranges Carla Soler,

More information

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies APPLICATION BENEFITS Regulatory guidelines and recommendations place a greater emphasis on the detection

More information

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1

More information

László Tölgyesi LC/MS scientist EFSC Demo Group. International Symposium on Food Safety and Quality: Applications of Nuclear and Related Techniques

László Tölgyesi LC/MS scientist EFSC Demo Group. International Symposium on Food Safety and Quality: Applications of Nuclear and Related Techniques Minimizing matrix effects in multiresidue pesticide analysis using a new sensitivity-enhanced triple quadrupole instrument in combination with extensive sample dilution László Tölgyesi LC/MS scientist

More information

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research Heather A Brown, 1 Claudia Rossi, 2 and Lisa J Calton 1 1 Waters Corporation, Wilmslow, UK 2

More information

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1

More information

Characterization of Carbon SPE for the Extraction of Polar Analytes

Characterization of Carbon SPE for the Extraction of Polar Analytes Characterization of Carbon SPE for the Extraction of Polar Analytes Cory Szafranski, Lydia Nolan, and William R. Betz Supelco, Supelco Park, Bellefonte, PA 16823 USA 1997 Sigma-Aldrich Co. T497277 BNG

More information

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method Xiang He and Marta Kozak ThermoFisher Scientific, San Jose, CA,

More information

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer APPLICATION NOTE 72385 Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer Authors Stephan Meding, Katherine Lovejoy, Martin Ruehl Thermo Fisher Scientific,

More information

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM Organics Revision Date: July 19, 2017 Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM Parameter Perfluorinated Alkyl Acids (Perfluorobutane Sulphonate (PFBS), Perflourooctane Sulphonate (PFOS),

More information

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS PO-CON1529E Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS ASMS 215 WP 77 Miho Kawashima 1, Yuka Fujito 2, Yayoi Ichiki 3, Miho Sakai 4, Takashi

More information

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry Shijun Lua, Buu N. Trana, Jamie L. Nelsenb, Kenneth M. Aldousa. Journal of Chromatography

More information

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 646 Triple Quadrupole LC/MS system with Triggered MRM Application Note Authors Thomas Glauner Agilent Technologies,

More information

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Q&A Transcript ---------------- Q - How do you generate multiple charges reproductively? A - If you use the same settings on the

More information

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS Dominic Roberts, 1 Sara Stead, 1 and Jennifer A. Burgess 2 1 Waters Corporation, Manchester, UK 2 Waters Corporation,

More information

Routine Multiresidue Pesticide Analysis using the Agilent 6470 Triple Quadrupole Mass Spectrometer

Routine Multiresidue Pesticide Analysis using the Agilent 6470 Triple Quadrupole Mass Spectrometer Routine Multiresidue Pesticide Analysis using the Agilent 6470 Triple Quadrupole Mass Spectrometer Application Note Food safety Authors Mark Sartain and Anabel Fandino Agilent Technologies, Inc. Santa

More information

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors Trace-Level Analysis of Melamine in Milk Products on Agilent 789A/5975C GC/MSD Using a ew Agilent J&W DB-5ms Ultra Inert Column and SampliQ SCX Cartridges Application ote Gas Chromatography/Mass Spectrometry/Food

More information

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry ISSN: 0973-4945; CODEN ECJHAO E- Chemistry http://www.e-journals.net 2010, 7(2), 403-408 Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass

More information

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity Janet Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS High

More information

Highly Sensitive and Rugged GC/MS/MS Tool

Highly Sensitive and Rugged GC/MS/MS Tool Highly Sensitive and Rugged GC/MS/MS Tool For Pesticide Multiresidue Analysis in Food Samples Agilent 7 Series Triple Quadrupole GC/MS. The world s first MS/MS designed specifically for GC Analysis Introduction

More information

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer Improved Screening for 2 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer Mary lackburn, Jia Wang, Jonathan eck, Charles Yang, Dipankar Ghosh, Thermo Fisher Scientific, San Jose, C,

More information

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses Technical Overview Authors Abstract Peter Stone, Thomas Glauner, Frank Kuhlmann, Tim Schlabach and Ken Miller

More information

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB. Quantitative analysis of small molecules in biological samples 100 Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB % 0 300 500 700 900 1100 1300 1500 1700 m/z Class Overview Introduction

More information

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction Testing for GHB in hair by GC tandem quadrupole MS Marie Bresson, Vincent Cirimele, Pascal Kintz, Marion Villain; Laboratoire Chemtox, Illkirch, France Timothy Jenkins, Waters Corporation, Manchester,

More information

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Marian Twohig, Michael D. Jones, Dominic Moore, Peter Lee, and Robert Plumb Waters Corporation, Milford, MA, USA APPLICATION

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 15641 August 2007 ICS 67.050 English Version Food analysis - Determination of pesticide residues by LC- MS/MS - Tandem mass spectrometric parameters

More information

Translational Biomarker Core

Translational Biomarker Core Translational Biomarker Core Instrumentation Thermo Scientific TSQ Quantum Triple Quadrupole Mass Spectrometers. There are two TSQ Quantum Ultra AM instruments available in the TBC. The TSQ Quantum Ultra

More information

Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404

Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404 Gas Chromatograph Mass Spectrometer No. GCMS-1404 Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030 Introduction Contamination of consumer products with pesticides is a growing concern

More information

Optimization of the sample preparation and extraction methodology

Optimization of the sample preparation and extraction methodology Supporting information Results and discussion Optimization of the sample preparation and extraction methodology Visual comparison of the slopes (curve in standard mixture vs MMC curve with identical concentration

More information

Analysis of Polar Metabolites using Mass Spectrometry

Analysis of Polar Metabolites using Mass Spectrometry Analysis of Polar Metabolites using Mass Spectrometry TransMed Course: Basics in Clinical Proteomics and Metabolomics. Oct 10-19, 2012 dd.mm.yyyy Vidya Velagapudi, Ph.D, Adjunct Professor Head of the Metabolomics

More information

Calibrating Thermo Exactive with the Direct Analysis in Real Time (DART) Ambient Ionization Source (Protocol Adapted from US FDA FCC)

Calibrating Thermo Exactive with the Direct Analysis in Real Time (DART) Ambient Ionization Source (Protocol Adapted from US FDA FCC) 1.0 Equipment: Calibrating Thermo Exactive with the Direct Analysis in Real Time (DART) Ambient Ionization Source (Protocol Adapted from US FDA FCC) Thermo Exactive Orbitrap Mass Spectrometer Direct Analysis

More information

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18 Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18 Column Xin Zhang, Jonathan P. Danaceau, and Erin E. Chambers Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Semi-validated

More information

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120 LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 10 Application Note Food Testing & Agriculture Author Irina Dioumaeva Agilent Technologies, Inc. Abstract

More information

Determination of Pharmaceuticals in Environmental Samples

Determination of Pharmaceuticals in Environmental Samples Determination of Pharmaceuticals in Environmental Samples BACKGROUND The full effects of pharmaceutical substances in the environment are largely unknown however the risk is significant enough that many

More information

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF application Note Liquid Chromatography/ Mass Spectrometry Author Sharanya Reddy PerkinElmer, Inc. Shelton, CT USA Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

More information

Fast Analysis of Chlorinated Phenoxy Herbicides in Environmental Samples by Negative ESI LC-MS/MS 14337

Fast Analysis of Chlorinated Phenoxy Herbicides in Environmental Samples by Negative ESI LC-MS/MS 14337 Fast Analysis of Chlorinated Phenoxy Herbicides in Environmental Samples by Negative ESI LC-MS/MS 14337 Wenjun Han, Ben Hicks, Elaine Wild TestAmerica Laboratories Inc. 13715 Rider Trail North, Earth City,

More information

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120 LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120 Application Note Food Testing & Agriculture Author Irina Dioumaeva Agilent Technologies, Inc. Abstract

More information

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS) Liquid Chromatography Mass Spectrometry (LC/MS) Prelab Questions: Questions to be answered before doing the experiment. The answers are due at the beginning of each experiment without exception (the questions

More information

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis Application Note AN89.V.1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Page 1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Prior to LC-MS/MS Analysis Sample Preparation

More information

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE Q-TOF PREMIER DYAMIC RAGE EHACEMET AD ACCURATE MASS MEASUREMET PERFORMACE Michael McCullagh, Jose Castro-Perez, and Lisa Calton Waters Corporation, Manchester, UK ITRODUCTIO The use of time-of-flight (TOF)

More information

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA).

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA). A Rapid and Sensitive Method for the Simultaneous Determination of and Cyanuric Acid in Infant Formulas, Adult utritional Products, and Protein Powders APPLICATIO BEEFITS Simultaneous high-throughput screening

More information

The Theory of HPLC. Quantitative and Qualitative HPLC

The Theory of HPLC. Quantitative and Qualitative HPLC The Theory of HPLC Quantitative and Qualitative HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference

More information

Validation Report 18

Validation Report 18 EURL for Cereals and Feeding stuff National Food Institute Technical University of Denmark Validation Report 18 Determination of pesticide residues in maize for livestock feed by GC-MS/MS and LC-MS/MS

More information

Mass Spectrometry in MCAL

Mass Spectrometry in MCAL Mass Spectrometry in MCAL Two systems: GC-MS, LC-MS GC seperates small, volatile, non-polar material MS is detection devise (Agilent 320-MS TQ Mass Spectrometer) Full scan monitoring SIM single ion monitoring

More information

LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges

LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges Application ote Food Testing & Agriculture Author Andy Zhai Agilent Technologies Shanghai Co. Ltd. Abstract This application

More information

Determination of Pesticides in Aqueous Samples by On-Line Coupling Solid-Phase Extraction to Gas Chromatography with At-Column Concentrating Interface

Determination of Pesticides in Aqueous Samples by On-Line Coupling Solid-Phase Extraction to Gas Chromatography with At-Column Concentrating Interface Application Note No. 033 Determination of Pesticides in Aqueous Samples by On-Line Coupling Solid-Phase Extraction to Gas Chromatography with At-Column Concentrating Interface Ryoichi Sasano*, Takayuki

More information

2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva

2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva 2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva Craig Dufresne and Kevin McHale, Content Creators The world leader in serving science The Whole Workflow Efficiency in sample

More information

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note Environmental Author Chin-Kai Meng Agilent Technologies 85 Centerville Road Wilmington, DE 988-6 USA Abstract Chlorinated

More information

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS PAGE: 1 of 14 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY CONTENTS 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS

More information

Available online Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article

Available online  Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2012, 4(6):3275-3279 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 Development and validation of a matrix solid-phase

More information

4.1 MATERIALS 4.2 EQUIPMENTS

4.1 MATERIALS 4.2 EQUIPMENTS 4.1 MATERIALS 1. Aceclofenac Moraceae Pharma Ltd., Uttarakhand, India 2. Diclofenac Arti Drugs Ltd., Mumbai, India 3. Paracetamol Moraceae Pharma Ltd., Uttarakhand, India 4. Para-aminophenol Hema Pharmaceuticals

More information

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes Joe DiBussolo, Marta Kozak Thermo Fisher Scientific, San Jose, CA Application

More information

CHEMICAL REMOVAL OF HUMIC SUBSTANCES INTERFERING WITH THE ON-LINE SOLID-PHASE EXTRACTION - LIQUID CHROMATOGRAPHIC DETERMINATION OF POLAR POLLUTANTS

CHEMICAL REMOVAL OF HUMIC SUBSTANCES INTERFERING WITH THE ON-LINE SOLID-PHASE EXTRACTION - LIQUID CHROMATOGRAPHIC DETERMINATION OF POLAR POLLUTANTS CHEMICAL REMOVAL OF HUMIC SUBSTANCES INTERFERING WITH THE ON-LINE SOLID-PHASE EXTRACTION - LIQUID CHROMATOGRAPHIC DETERMINATION OF POLAR POLLUTANTS ABSTRACT Different methods for removing interference

More information

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring High-Throughput Protein Quantitation Using Multiple Reaction Monitoring Application Note Authors Ning Tang, Christine Miller, Joe Roark, Norton Kitagawa and Keith Waddell Agilent Technologies, Inc. Santa

More information

Journal of Chromatography A, 1109 (2006)

Journal of Chromatography A, 1109 (2006) Journal of Chromatography A, 1109 (2006) 242 252 Multiresidue liquid chromatography tandem mass spectrometry determination of 52 non gas chromatography-amenable pesticides and metabolites in different

More information

Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1

Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1 Application Note AutoMate-Q40 Automated QuEChERS Extraction for Pesticide Residues in Botanicals Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1 Abstract QuEChERS is a Quick-Easy-Cheap-

More information

Determination of urea in ultrapure water by IC-MS/MS

Determination of urea in ultrapure water by IC-MS/MS APPLICATION NOTE 72482 Determination of urea in ultrapure water by IC-MS/MS Authors Soon Fatt Lee, 1 Fiona Teh Hui Boon, 1 Chris Cheah Hun Teong, 1 and Jeff Rohrer 2 ¹Thermo Fisher Scientific, Singapore

More information

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS Jason Lai, Jia Wang, Brad Hart, Pavel Aronov, Kristine Van Natta, Marta Kozak, Jorge Valdivia, Andy Jacobs, Haibo

More information

Determination of Aminoglycosides in animal tissue by means of LC/MS-MS

Determination of Aminoglycosides in animal tissue by means of LC/MS-MS Austrian Agency for Health and Food Safety (AGES) Determination of Aminoglycosides in animal tissue by means of LC/MS-MS Created / revised Technical check QM check Release Name Thomas Aichinger Martin

More information

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS PesticideScreener Comprehensive Pesticide Screening and Quantitation Innovation with Integrity UHR-TOF MS The Challenge of Comprehensive Pesticide Residue Analysis The use of pesticides to reduce crop

More information