Rapid moisture measurement with microwave resonance technology in infant formulas

Size: px
Start display at page:

Download "Rapid moisture measurement with microwave resonance technology in infant formulas"

Transcription

1 6 th Conference on Water in Food Maison des Agriculteurs March 2010 Reims France Rapid moisture measurement with microwave resonance technology in infant formulas Georg Merkh, Marion Dambacher and Heinz-Dieter Isengard University of Hohenheim, Institute of Food Technology D Stuttgart, Germany

2 Water content in infant formula - physical properties - technological processes - microbiological stability and shelf life - nutritional value - economic aspects, trade value - legal issues

3 Microwave resonance technology tube sensors and analyzers for laboratory use

4 Microwave resonance technology different types of sensors

5 Microwave resonance technology handheld instruments

6 Microwave resonance technology characteristic microwave resonance of resonator Microwave Generator Microwave Detector resonator empty transmission f 0 frequency

7 Microwave resonance technology resonance shift induced by product resonator with dry product transmission f 1 f 0 frequency

8 Microwave resonance technology shift and attenuation induced by moisture resonator with wet product transmission f 2 f 1 f 0 frequency

9 Microwave resonance technology measuring resonance shift and bandwidth frequency shift: f0 f1 = A parameter bandwidth increase: b1 b0 = B parameter b0 b1 transmission f 1 f 0 frequency

10 Microwave resonance technology moisture independent of sample density and quantity 0.10 measuring two independent parameters A and B allows calculating a moisture value independent of density and quantity impacts. increase of resonance bandwith (B-Parameter) influence of sample density, quantity influence of sample moisture shift of resonance frequency (A Parameter)

11 Microwave resonance technology calculating moisture value 0.10 A and B parameters are measured α = arctan (B / A) α is proportional to moisture increase of resonance bandwith (B-Parameter) α2 Sample # 2 Sample # 1 α shift of resonance frequency (A Parameter)

12 Drying techniques - for the calibration curves different samples were dried in a drying oven at 80 C, 100 C and 120 C, and in a vacuum drying oven at 50 C. - after cooling down their loss of mass was measured, the microwave-moisture-value registered and the water content determined by Karl Fischer titration or gas extraction followed by Karl Fischer titration

13 Karl Fischer titration: CH 3 OH + SO 2 + Z ZH + + CH 3 OSO 2 (1) ZH + + CH 3 OSO 2 + I 2 + H 2 O + 2 Z 3ZH + + CH 3 OSO I or ZH + + CH 3 OSO 2 + I 3 + H 2 O + 2 Z 3ZH + + CH 3 OSO I (2a) (2b) Z = Base, mostly imidazole and no longer the historic pyridine

14 1 mol I 2 indicates 1 mol H 2 O. from the consumption of I 2 the amount or the concentration of H 2 O can be calculated.

15 Karl Fischer titration: - titration at 40 C 30 ml Hydranal -Solvent and 10 ml formamide - extraction time of 10 min - 5 replicates

16 Automated Karl Fischer titration with heating oven combination of a drying method and coulometric Karl Fischer Titration

17 Automated Karl Fischer titration with heating oven principle of gas extraction

18 Automated Karl Fischer titration with heating oven

19 Results and discussion drying curve of Bebivita dried at 80 C

20 Results and discussion calibration of Bebivita with conventional Karl Fischer titration as reference

21 Results and discussion drying curve of Bebivita dried at 80 C water contents were measured by KFT-ho

22 Results and discussion calibration of Bebivita with Karl Fischer titration with heating oven as reference

23 Results and discussion calibration of two drying curves at 80 C of Bebivita with Karl Fischer titration with heating oven as reference

24 Conclusion the microwave resonance technology can be used for rapid measurement of the moisture content in infant formulas the calibrations are highly affected by the production parameters of the product

25 Conclusion the Karl Fischer titration with heating oven seems to be a very acceptable reference method the major benefit of the microwave resonance technique is the very short testing time and the possibility to use it online.

26 Thank you very much for your attention

The influence of the reference method on the results of the secondary method via calibration

The influence of the reference method on the results of the secondary method via calibration The influence of the reference method on the results of the secondary method via calibration Heinz-Dieter Isengard 1, Georg Merkh 1 and Clément Dubois 2 1 University of Hohenheim, Institute of Food Science

More information

University of Hohenheim Institute of Food Technology Food Analysis

University of Hohenheim Institute of Food Technology Food Analysis University of Hohenheim Institute of Food Technology Food Analysis Proposal of a New Reference Method to Determine the Water Content of Dried Milk Products Renate Kling 29-30 March 2004 Background Diploma

More information

Karl Fischer Titration Of Food : Towards Complete Automation

Karl Fischer Titration Of Food : Towards Complete Automation Karl Fischer Titration Of Food : Towards Complete Automation Cosimo A. De Caro, A. Aichert, C. Gordon Mettler-Toledo GmbH, Analytical CH-8603 Schwerzenbach, Switzerland Program Introduction Why water determination

More information

Citric Acid Analysis L-6-1. MOISTURE (Karl Fischer)

Citric Acid Analysis L-6-1. MOISTURE (Karl Fischer) Citric Acid Analysis L-6-1 MOISTURE (Karl Fischer) PRINCIPLE SCOPE The sample is dissolved in a mixture of methanol and formamide (50:50 v/v) and then titrated with standardized Karl Fischer reagent. The

More information

Water content in industrial food Is scientific evidence enough to establish an analytical standard method?

Water content in industrial food Is scientific evidence enough to establish an analytical standard method? Water content in industrial food Is scientific evidence enough to establish an analytical standard method? Heinz-Dieter Isengard University of Hohenheim Institute of Food Science and Biotechnology Department

More information

Aquagent. The Scharlau comprehensive pyridine-free solutions range for a reliable Karl Fischer Titration

Aquagent. The Scharlau comprehensive pyridine-free solutions range for a reliable Karl Fischer Titration The Scharlau comprehensive pyridine-free solutions range for a reliable Karl Fischer Titration Karl Fischer titration is a well known and globally accepted method for water determination since the beginning

More information

Certificate of Analysis

Certificate of Analysis Certificate of Analysis Reference Material - Primary Standard Product Name: Metoprolol Tartrate 1.0 mg/ml in Methanol (as free base) Catalogue Number: LGCAMP0027.00-01 Lot Number: 8525 CAS Number: 56392-17-7

More information

Sensing the Moisture Content of Dry Cherries A Rapid and Nondestructive Method

Sensing the Moisture Content of Dry Cherries A Rapid and Nondestructive Method Food and Nutrition Sciences, 013, 4, 38-4 http://dx.doi.org/10.436/fns.013.49a006 Published Online September 013 (http://www.scirp.org/journal/fns) Sensing the Moisture Content of Dry Cherries A Rapid

More information

Corn Sugar (crude & refined) Analysis F MOISTURE (Karl Fischer)

Corn Sugar (crude & refined) Analysis F MOISTURE (Karl Fischer) Corn Sugar (crude & refined) Analysis F-32-1 MOISTURE (Karl Fischer) PRINCIPLE SCOPE The sugar sample is dissolved in a mixture of methanol and formamide (50:50 v/v) and then titrated with standardized

More information

Methods of Asphalt Characterization for Understanding the link between Chemistry and Material Failure FHWA Project Review January 26, 2012

Methods of Asphalt Characterization for Understanding the link between Chemistry and Material Failure FHWA Project Review January 26, 2012 Methods of Asphalt Characterization for Understanding the link between Chemistry and Material Failure FHWA Project Review January 26, 2012 Ryan B. Boysen John F. Schabron Eric W. Kalberer Joseph F. Rovani

More information

[RNH]SO3CH3 [RNH]SO 4 CH [RNH]I

[RNH]SO3CH3 [RNH]SO 4 CH [RNH]I Product bulletin Karl Fischer Tritration The basics of Karl Fischer Tritration Karl Fischer titration is an analytical technique to measure the amount of water contained in various samples, which may be

More information

Analytix. HYDRANAL Product Line Overview

Analytix. HYDRANAL Product Line Overview 1 Analytix HYDRANAL Product Line Overview Volumetric Titration with One-Component Reagents Volumetric Titration with Two-Component Reagents Coulometric Titration with Water Standards E Types HYDRANAL Reagents

More information

Hy = KFt Ori x Acy. HYDRANAL Product Overview Guide. Hydranal TM. Karl Fischer titration. Research Chemicals. Discover the perfect formula

Hy = KFt Ori x Acy. HYDRANAL Product Overview Guide. Hydranal TM. Karl Fischer titration. Research Chemicals. Discover the perfect formula Research Chemicals Hy = KFt Ori x Acy Hydranal TM Karl Fischer titration Original Accuracy Discover the perfect formula HYDRANAL Product Overview Guide Reagents for water determination by Karl Fischer

More information

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017. Final Report Title Characterisation of Job No 2016/11/12-34 AS No. 1234A Client Contact Sample Author report Signed Date 2017 Easy Reach Report 2017 v2.docx 1 of 33 Contents 1. Study Summary Page 3 2.

More information

Certificate of Analysis

Certificate of Analysis Certificate of Analysis Reference Material - Primary Standard Product Name: Oxycodone 1.0 mg/ml in Methanol Catalogue Number: Lot Number: 37583 LGCAMP0672.10-01 CAS Number: 76-42-6 Molecular Formula: C

More information

CIGRE SC A2 & D1 JOINT COLLOQUIUM 2011, KYOTO JAPAN. Water Saturation Limits and Moisture Equilibrium Curves of Alternative Insulation Systems

CIGRE SC A2 & D1 JOINT COLLOQUIUM 2011, KYOTO JAPAN. Water Saturation Limits and Moisture Equilibrium Curves of Alternative Insulation Systems CIGRE SC A2 & D1 JOINT COLLOQUIUM 2011, KYOTO JAPAN http://cigre2011-a2d1.org/ CIGRE A2 & D1 2011 Doshisha University, Kyoto PS2: Materials Water Saturation Limits and Moisture Equilibrium Curves of Alternative

More information

Certificate of Analysis

Certificate of Analysis Certificate of Analysis Reference Material - Primary Standard Product Name: LSD (Lysergic Acid Diethylamide) 1.0 mg/ml in Acetonitrile Catalogue Number: Lot Number: 16905 LGCAMP1346.00-11 O CAS Number:

More information

Period of validity: to date of issue:

Period of validity: to date of issue: Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-RM-14176-01-00 according to the relevant clauses of ISO Guide 34: and DIN EN ISO/IEC 17025:2005 Period of validity: 11.01.2016

More information

Certificate of Analysis

Certificate of Analysis Certificate of Analysis Reference Substance Benzoic Acid Catalogue Number: Lot Number: 43480 LGCFOR0278.01 Molecular Formula: C 7 H 6 O 2 Molecular Weight: 122.12 CAS Number: [ 65-85-0 ] Long-term Storage:

More information

Geavanceerde bepaling van water in poeders en vaste stoffen via geautomatiseerde Karl Fischer titratie. Peter van de Spreng 8 November 2011

Geavanceerde bepaling van water in poeders en vaste stoffen via geautomatiseerde Karl Fischer titratie. Peter van de Spreng 8 November 2011 Geavanceerde bepaling van water in poeders en vaste stoffen via geautomatiseerde Karl Fischer titratie Peter van de Spreng 8 November 2011 Mettler Toledo Theory Agenda Types of water Which samples - Karl

More information

Understanding Importance of Water Sorption Isotherm Shape, Hysteresis, and Models on Pharmaceutical Materials

Understanding Importance of Water Sorption Isotherm Shape, Hysteresis, and Models on Pharmaceutical Materials Understanding Importance of Water Sorption Isotherm Shape, Hysteresis, and Models on Pharmaceutical Materials Dr. Daniel J. Burnett Surface Measurement Systems, Ltd. Dburnett@surfacemeasurementsystems.com

More information

Hy + Hw = Cy + Inv. Discover the perfect formula. Hydranal TM Honeywell Consistency Innovation

Hy + Hw = Cy + Inv. Discover the perfect formula. Hydranal TM Honeywell Consistency Innovation Hy + Hw = Cy + Inv Hydranal TM Honeywell Consistency Innovation Discover the perfect formula HYDRANAL Product Overview Guide Reagents for water determination by Karl Fischer titration HYDRANAL Reagents

More information

Karl Fischer Volumetric Titration Theory and Practice

Karl Fischer Volumetric Titration Theory and Practice Karl Fischer Volumetric Titration Theory and Practice - 1 - - when you need to be sure... Table of contents Introduction... 3 Chemical reactions... 3 ph considerations... 4 Volumetric titration... 4 General

More information

On-line Monitoring of Water during Reference Material Production by AOTF-NIR Spectrometry

On-line Monitoring of Water during Reference Material Production by AOTF-NIR Spectrometry On-line Monitoring of Water during Reference Material Production by AOTF-NIR Spectrometry Håkan Emteborg, Vikram Kestens and Alexander Bernreuther Institute for Reference Materials and Measurements (IRMM)

More information

J.T.Baker Brand HYDRA-POINT KARL FISCHER REAGENTS. Europe Middle East Africa

J.T.Baker Brand HYDRA-POINT KARL FISCHER REAGENTS. Europe Middle East Africa J.T.Baker Brand HYDRA-POINT KARL FISCHER REAGENTS Europe Middle East Africa Lab-Optimized Performance: Function-tested Karl Fischer reagents from the brand that delivers quality and purity. The J.T.Baker

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD INTERNATIONAL ORGANIZATION FOR STANDARDIZATIONWEWlYHAPOCIHAR OPrAHM3ALlMR l-l0 CTAH~APTbl3ALWl.ORGANlSATlON INTERNATIONALE DE NORMALISATION Determination of water - Karl Fischer

More information

Authors: Philippe Lam, Sr. Engineer. Genentech, Inc., Pharmaceutical Process R&D, 1 DNA Way, South San Francisco, CA 94080

Authors: Philippe Lam, Sr. Engineer. Genentech, Inc., Pharmaceutical Process R&D, 1 DNA Way, South San Francisco, CA 94080 Authors: Philippe Lam, Sr. Engineer. Genentech, Inc., Pharmaceutical Process R&D, 1 DNA Way, South San Francisco, CA 94080 Mike Nariman, AB Control, Inc., Irvine, CA, www.abcontrols.com. Abstract Genentech

More information

Nuclear Gauges and Cores HOW CAN WE GET THE BEST CONSISTENCY AND CORRELATION PERTAINING TO DENSITY?

Nuclear Gauges and Cores HOW CAN WE GET THE BEST CONSISTENCY AND CORRELATION PERTAINING TO DENSITY? Nuclear Gauges and Cores HOW CAN WE GET THE BEST CONSISTENCY AND CORRELATION PERTAINING TO DENSITY? Introduction Nuclear Gauge Performance can be associated with the operator, equipment s functionality,

More information

Functionalization of the Aryl Moiety in the Pincer Complex. (NCN)Ni III Br 2 :

Functionalization of the Aryl Moiety in the Pincer Complex. (NCN)Ni III Br 2 : Electronic Supporting Information For : Functionalization of the Aryl Moiety in the Pincer Complex (NCN)Ni III Br 2 : Insights on Ni III -Promoted Carbon-Heteroatom Coupling Jean-Philippe Cloutier and

More information

Annex to the Accreditation Certificate D-RM according to ISO Guide 34:2009 and DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-RM according to ISO Guide 34:2009 and DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-RM-14176-01-00 according to ISO Guide 34:2009 and DIN EN ISO/IEC 17025:2005 Period of validity: 21.04.2017 to 04.08.2019 date

More information

Certificate of Analysis

Certificate of Analysis Certificate of Analysis LGC Quality ISO Guide 34:2009 DAkkS D-RM-14176-01-00 ISO/IEC 17025:2005 DAkkS D-PL-14176-01-00 ISO 9001:2008 DQS 102448 QM08 Primary Reference Standard Tilidine Hydrochloride Hemihydrate

More information

Reliable, fast and accurate WVTR measurement technology. Dr. Jörg Koch SEMPA SYSTEMS GmbH

Reliable, fast and accurate WVTR measurement technology. Dr. Jörg Koch SEMPA SYSTEMS GmbH Reliable, fast and accurate WVTR measurement technology Dr. Jörg Koch SEMPA SYSTEMS GmbH INTRODUCTION Starting point Food industry Pharmaceutical industry Anorganic solar cells Organic solar cells Vacuum

More information

Water Detection and Quantification in Polymers Using a Non-destructive Microwave Technique

Water Detection and Quantification in Polymers Using a Non-destructive Microwave Technique 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16456 Water Detection and Quantification in

More information

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

PTG-NIR Powder Characterisation System (not yet released for selling to end users) Powder Characterisation System - PTG-NIR PTG-NIR Powder Characterisation System (not yet released for selling to end users) The PTG-NIR automatic powder and granule inspection system with integrated NIR

More information

PC Control / Touch Control

PC Control / Touch Control PC Control / Touch Control Version 6.0 / 5.840.0150 New Features Manual 8.840.8007EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com

More information

Validation report and uncertainty budget of Coulometric Karl Fischer titrator with an oven system

Validation report and uncertainty budget of Coulometric Karl Fischer titrator with an oven system SIB64 METefnet 27.05.2016 Validation report and uncertainty budget of Coulometric Karl Fischer titrator with an oven system Findings at UT and BRML-INM Deliverable 1.2.5 Rudolf Aro, Lauri Jalukse, Ivo

More information

Certificate of Analysis

Certificate of Analysis Certificate of Analysis Reference Substance Atorvastatin Calcium Catalogue Number: Lot Number: 55085 LGCFOR0400.00 Molecular Formula: 2C 33 H 34 FN 2 O 5 Ca Molecular Weight: 1155.34 CAS Number: [ 134523-03-8

More information

Supporting Information

Supporting Information Supporting Information An Extremely Active and General Catalyst for Suzuki Coupling Reactions of Unreactive Aryl Chlorides Dong-Hwan Lee and Myung-Jong Jin* School of Chemical Science and Engineering,

More information

Certificate of Analysis

Certificate of Analysis Certificate of Analysis Reference Substance Cefalexin Monohydrate Catalogue Number: Lot Number: 38530 LGCFOR0605.00 Molecular Formula: C 16 H 17 N 3 O 4 S H 2 O Molecular Weight: 365.40 CAS Number: [ 23325-78-2

More information

KF875 and KF UNI Coulometric Karl Fischer Titrators

KF875 and KF UNI Coulometric Karl Fischer Titrators KF875 and KF UNI Coulometric Karl Fischer Titrators User Guide MEGGER v.02/03 CONTENTS CONTENTS... 3 PARTS LIST... 4 SPECIFICATIONS & FEATURES... 5 PRINCIPLE OF MEASUREMENT... Error! Bookmark not defined.

More information

Certificate of Analysis

Certificate of Analysis Certificate of Analysis Reference Substance Dehydronorketamine Hydrochloride Catalogue Number: Lot Number: 14579 LGCFOR0144.07 Molecular Formula: C 12 H 12 ClNO HCl Molecular Weight: 258.14 CAS Number:

More information

Water content of flavonoid / cyclodextrin nanoparticles

Water content of flavonoid / cyclodextrin nanoparticles PLITEHNICA UNIVERSITY F TIMIŞARA - RMANIA Faculty of Industrial Chemistry and Environmental Engineering Water content of flavonoid / cyclodextrin nanoparticles Authors: Daniel I. Hădărugă, Nicoleta G.

More information

Water in freeze-dried lactic acid bacteria: Friend or Foe

Water in freeze-dried lactic acid bacteria: Friend or Foe EuroFoodWater, 22-23 March, Reims, France Water in freeze-dried lactic acid bacteria: Friend or Foe Stéphanie Passot, Stéphanie Cenard, Inès Douania, Cristian Tréléa, Fernanda Fonseca Joint Research Unit

More information

Solid State Science and Technology, Vol. 19, No 1 (2011) ISSN MICROWAVE DIELECTRIC CHARACTERIZATION OF TURMERIC

Solid State Science and Technology, Vol. 19, No 1 (2011) ISSN MICROWAVE DIELECTRIC CHARACTERIZATION OF TURMERIC Solid State Science and Technology, Vol. 19, No 1 (211) 26-211 ISSN 128-7389 MICROWAVE DIELECTRIC CHARACTERIZATION OF TURMERIC Azila Aziz 1, Jumiah Hassan 1,2, Kaida Khalid 1 and Zulkifly Abbas 1 1 Department

More information

REVIEW Chapters 0-3,

REVIEW Chapters 0-3, REVIEW Chapters 0-3, 7.1-7.2 "When you can measure what you are speaking about, and express it in numbers, you know something about it; but when you cannot express it in numbers your knowledge is of a

More information

Titration a solution of known concentration, called a standard solution

Titration a solution of known concentration, called a standard solution Acid-Base Titrations Titration is a form of analysis in which we measure the volume of material of known concentration sufficient to react with the substance being analyzed. Titration a solution of known

More information

Comparing Various Moisture Determination Methods for Power Transformers MAIK KOCH*, MICHAEL KRÜGER, STEFAN TENBOHLEN

Comparing Various Moisture Determination Methods for Power Transformers MAIK KOCH*, MICHAEL KRÜGER, STEFAN TENBOHLEN , rue d Artois, F-78 PARIS reference CIGRE 9 http : //www.cigre.org Southern Africa Regional Conference Comparing Various Moisture Determination Methods for Power Transformers MAIK KOCH*, MICHAEL KRÜGER,

More information

WATER. Brighter. Determination. Aquastar reagents for brilliant Karl Fischer titration results.

WATER. Brighter. Determination. Aquastar reagents for brilliant Karl Fischer titration results. Brighter WATER Determination Aquastar reagents for brilliant Karl Fischer titration results. The life science business of Merck KGaA, Darmstadt, Germany operates as MilliporeSigma in the U.S. and Canada.

More information

ORACLE. FIRST EVER RAPID FAT ANALYZER with No Method Development

ORACLE. FIRST EVER RAPID FAT ANALYZER with No Method Development ORACLE FIRST EVER RAPID FAT ANALYZER with No Method Development ORACLE NMR with No Method Development NEW Fat Analysis Analyze any food sample in less than 30 seconds REVOLUTIONARY Unmatched repeatability

More information

Certificate of Analysis

Certificate of Analysis Certificate of Analysis Reference Substance N-Desmethylclobazam (Norclobazam) Catalogue Number: Lot Number: 16595 LGCFOR0910.01 Molecular Formula: C 15 H 11 ClN 2 O 2 Molecular Weight: 286.71 CAS Number:

More information

Determination of Nutrients. Determination of Kjeldahl nitrogen. Introduction

Determination of Nutrients. Determination of Kjeldahl nitrogen. Introduction Determination of Nutrients Determination of Kjeldahl nitrogen Introduction This document is developed in the project Horizontal. It is the result of desk study Determination of total phosphorus and nitrogen

More information

A Review on Microwave Based Moisture Measurement System for Granular Materials

A Review on Microwave Based Moisture Measurement System for Granular Materials IOSR Journal of Electronics and Communication Engineering (IOSR-JECE) ISSN: 2278-2834, ISBN: 2278-8735. Volume 3, Issue 2 (Sep-Oct. 2012), PP 37-41 A Review on Microwave Based Moisture Measurement System

More information

4023 Synthesis of cyclopentanone-2-carboxylic acid ethyl ester from adipic acid diethyl ester

4023 Synthesis of cyclopentanone-2-carboxylic acid ethyl ester from adipic acid diethyl ester NP 4023 Synthesis of cyclopentanone-2-carboxylic acid ethyl ester from adipic acid diethyl ester NaEt C 10 H 18 4 Na C 2 H 6 C 8 H 12 3 (202.2) (23.0) (46.1) (156.2) Classification Reaction types and substance

More information

A critical assessment of the mechanisms governing the formation of aqueous biphasic systems composed of protic ionic liquids and polyethylene glycol

A critical assessment of the mechanisms governing the formation of aqueous biphasic systems composed of protic ionic liquids and polyethylene glycol Electronic Supplementary Material (ESI) for Physical Chemistry Chemical Physics. This journal is the Owner Societies 2016 A critical assessment of the mechanisms governing the formation of aqueous biphasic

More information

The Characteristics of a Soln

The Characteristics of a Soln Goal 1 The Characteristics of a Soln Define the term solution, and, given a description of a substance, determine if it is a solution. The Characteristics of a Soln Solution (as used in chemistry) A homogenous

More information

Water in Food 3 rd International Workshop. Water Analysis of Food Products with at-line and on-line FT-NIR Spectroscopy. Dr.

Water in Food 3 rd International Workshop. Water Analysis of Food Products with at-line and on-line FT-NIR Spectroscopy. Dr. Water in Food 3 rd International Workshop Water Analysis of Food Products with at-line and on-line FT-NIR Spectroscopy Dr. Andreas Niemöller Lausanne 29th 30th March 2004 Bruker Group Company Technology

More information

á921ñ WATER DETERMINATION

á921ñ WATER DETERMINATION USP 40 Physical Tests / á921ñ Water Determination 1 á921ñ WATER DETERMINATION Many Pharmacopeial articles either are hydrates or contain water in adsorbed form. As a result, the determination of the water

More information

ICP-MS. High Resolution ICP-MS.

ICP-MS. High Resolution ICP-MS. ICP-MS attom ES High Resolution ICP-MS www.nu-ins.com Attom ES Enhanced Sensitivity Enhanced Speed Enhanced Selectivity Enhanced Software The Attom ES from Nu Instruments is a double focussing inductively

More information

Karl-Fischer Titration the method for determining water

Karl-Fischer Titration the method for determining water Karl-Fischer Titration the method for determining water Quite some experienced analyst will be unpleasantly reminded by the pyridine smell, when hearing the name Karl Fischer. However, modern reagents

More information

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission 0 chapter Sodium and Potassium Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission Spectroscopy 67 S. S. Nielsen (ed.), Food Analysis Laboratory Manual Springer

More information

The remaining questions were developed by John Gelder.

The remaining questions were developed by John Gelder. 1.Design an experiment to collect data that supports the claim that a 1.0 M NaCl solution is a homogeneous mixture. Describe the steps, the data you would collect, and how the data support the claim. Laboratory

More information

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Application Note Food Authors Jianqiu Mi, Zhengxiang Zhang, Zhixu Zhang,

More information

A novel smart polymer responsive to CO 2

A novel smart polymer responsive to CO 2 A novel smart polymer responsive to CO 2 Zanru Guo, a,b Yujun Feng,* a Yu Wang, a Jiyu Wang, a,b Yufeng Wu, a,b and Yongmin Zhang a,b a Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences,

More information

Automating Wet Chemical Analysis. William Lipps Market Specialist for Water Analyzer Products December 11, 2008

Automating Wet Chemical Analysis. William Lipps Market Specialist for Water Analyzer Products December 11, 2008 Automating Wet Chemical Analysis William Lipps Market Specialist for Water Analyzer Products December 11, 2008 The advantages of automating wet chemical analysis. Save time Decrease cost Improve quality

More information

Pyrolysis process for the treatment of food waste. Barbora Grycová VSB - Technical University of Ostrava Czech Republic

Pyrolysis process for the treatment of food waste. Barbora Grycová VSB - Technical University of Ostrava Czech Republic Pyrolysis process for the treatment of food waste Barbora Grycová VSB - Technical University of Ostrava Czech Republic INTRODUCTION Wastes from the food production are still mostly disposed of by landfilling,

More information

Application Determination of water in petrochemistry products using Titrator TitroLine 7500 KF trace

Application Determination of water in petrochemistry products using Titrator TitroLine 7500 KF trace Determination of water in petrochemistry products using Titrator TitroLine 7500 KF trace Date: 06.05.2013 Page 1 of 6 Use The application describes the procedure of the coulometric water determination

More information

Milk Analysis with the TIDAS P Milk Inspector

Milk Analysis with the TIDAS P Milk Inspector Milk Analysis with the TIDAS P Milk Inspector In Cooperation with the German Schwarzwald Milch GmbH a milk analysis system was developed, which is able to measure the percentage of fat, protein and dry

More information

Catalytic Reductive Dehydration of Tertiary Amides to Enamines under Hydrosilylation Conditions

Catalytic Reductive Dehydration of Tertiary Amides to Enamines under Hydrosilylation Conditions SUPPORTIG IFORMATIO Catalytic Reductive Dehydration of Tertiary Amides to Enamines under Hydrosilylation Conditions Alexey Volkov, a Fredrik Tinnis, a and Hans Adolfsson.* a a Department of Organic Chemistry,

More information

Synthesis and preliminary biological evaluation of carba analogues. from Neisseria meningitidis A capsular polysaccharide

Synthesis and preliminary biological evaluation of carba analogues. from Neisseria meningitidis A capsular polysaccharide Synthesis and preliminary biological evaluation of carba analogues from Neisseria meningitidis A capsular polysaccharide Qi Gao, a Cristina Zaccaria, a Marta Tontini, b Laura Poletti, a Paolo Costantino,

More information

Comparison of methods for the determination the fat content of meat

Comparison of methods for the determination the fat content of meat 57 th Annual Meeting Of The European Association For Animal Production, Antalaya, Turkey, September 17-20, 2006 (N32.20) Comparison of methods for the determination the fat content of meat Seenger J 1.,

More information

National standard of People s Republic of China

National standard of People s Republic of China National standard of People s Republic of China GB5413.24-2010 Determination of chlorine in foods for infants and young children, raw milk and dairy products Issued at 2010-03-2 Implemented at:2010-06-01

More information

1. Introduction. 2. Equipment. 3. Chemicals and Materials

1. Introduction. 2. Equipment. 3. Chemicals and Materials 1. Introduction Nitrogen and protein determination in food and feed are described in numerous standard procedures [1-3]. Therein, the titration specifications vary between boric acid and back titration.

More information

Spectroscopy and Chromatography

Spectroscopy and Chromatography Spectroscopy and Chromatography Introduction Visible light is one very small part of the electromagnetic spectrum. The different properties of the various types of radiation depend upon their wavelength.

More information

Supplementary Material for. Zinc Oxide-Black Phosphorus Composites for Ultrasensitive Nitrogen

Supplementary Material for. Zinc Oxide-Black Phosphorus Composites for Ultrasensitive Nitrogen Electronic Supplementary Material (ESI) for Nanoscale Horizons. This journal is The Royal Society of Chemistry 2018 Supplementary Material for Zinc Oxide-Black Phosphorus Composites for Ultrasensitive

More information

CERTIFICATE OF ANALYSIS

CERTIFICATE OF ANALYSIS CERTIFICATE OF ANALYSIS Processed meat Proximates, chloride, nitrate and hydroxyproline Constituent Number of laboratories Certified value 2,3 Uncertainty 4 Moisture 1 (g/kg) 18 618 7 Nitrogen 1 (g/kg)

More information

Microwave Dielectric Properties of Four Types of Rhizomes from Zingiberaceace Family

Microwave Dielectric Properties of Four Types of Rhizomes from Zingiberaceace Family Journal of Physical Science, Vol. 28(1), 15 26, 17 Microwave Dielectric Properties of Four Types of Rhizomes from Zingiberaceace Family Nor Azila Abd. Aziz, 1* Jumiah Hassan, 1,2 Zulkifly Abbas 1 and Nurul

More information

KEM SET. for FOOD. Salinity. Brix Density Concentration. Acid Value POV. Water Content

KEM SET. for FOOD. Salinity. Brix Density Concentration. Acid Value POV. Water Content Salinity for FOOD Brix Density Concentration Acid Value POV Water Content Vitamin C Acid Value / POV Salinity Vitamin C for FOOD A Automatic Potentiometric Titrator B Automatic Potentiometric Titrator

More information

From 1 ppm to 100% Karl Fischer water content determination

From 1 ppm to 100% Karl Fischer water content determination METTLER TOLEDO Karl Fischer Titrators DL39 & DL32 Coulometers DL38 & DL31 Volumeters Oven sample changer Stromboli From 1 ppm to 100% Karl Fischer water content determination Karl Fischer water content

More information

T 282. WORKING GROUP CHAIRMAN Junyong Zhu SUBJECT

T 282. WORKING GROUP CHAIRMAN Junyong Zhu SUBJECT NOTICE: This is a DRAFT of a TAPPI Standard in ballot. Although available for public viewing, it is still under TAPPI s copyright and may not be reproduced or distributed without permission of TAPPI. This

More information

Europa. Gottlieb Daimler (on the left) in his Motorcoach (about 1887)

Europa. Gottlieb Daimler (on the left) in his Motorcoach (about 1887) Hohenheim Castle Location Germany State Baden-Württemberg Europa Gottlieb Daimler (on the left) in his Motorcoach (about 1887) Baden-Württemberg Building blocks for the future Photonic crystals fabricated

More information

Supporting Information

Supporting Information Electronic Supplementary Material (ESI) for Dalton Transactions. This journal is The Royal Society of Chemistry 2016 Supporting Information Polystyrene Sulfonate Threaded in MIL-101Cr(III) as Stable and

More information

Your partner in Science!

Your partner in Science! Your partner in Science! Your partner in Science! Laser Diffraction Particle Size Distribution Analyzer LA-960 Simple, Powerful, Reliable 10 nm - 5 mm The LA-960 features intuitive software, unique accessories,

More information

F r a U n h o F E r I n s T I T U T E F o r C h E M I C a l T E C h n o l o g y I C T EnErgEtic MatErials ParticlE technology

F r a U n h o F E r I n s T I T U T E F o r C h E M I C a l T E C h n o l o g y I C T EnErgEtic MatErials ParticlE technology FRAUNHOFER INSTITUTE FoR Chemical TEchnology ICT Energetic Materials Particle Technology 1 2 Due to the wide variety of industrial products available in particle form, particle technology has a high technological

More information

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation What type of samples are common? Sample preparation 1 2 Number of samples? Time spent on different operations during LC analyses 3 4 Sources of error Aims Sample has to be representative Sample has to

More information

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable Compact Titration Compact Titrator G20 One Click Titration Simple & Dependable Simplicity The Intelligent Helper for Simple Titrations One Click Titration Intuitive method adaptation Accurate results simply

More information

Basic Equipment. 2D.1 Equipment for Measuring Mass

Basic Equipment. 2D.1 Equipment for Measuring Mass Basic Equipment The array of equipment for making analytical measurements is impressive, ranging from the simple and inexpensive, to the complex and expensive. With three exceptions measuring mass, measuring

More information

6 th International Conference on Electromagnetic Wave Interaction with Water and Moist Substances

6 th International Conference on Electromagnetic Wave Interaction with Water and Moist Substances 6 th International Conference on Electromagnetic Wave Interaction with Water and Moist Substances Papers, Posters and Exhibits Conference Proceedings + CD-ROM Editor: Klaus Kupfer Co-Editors: Christof

More information

Module 2. Measurement Systems. Version 2 EE IIT, Kharagpur 1

Module 2. Measurement Systems. Version 2 EE IIT, Kharagpur 1 Module 2 Measurement Systems Version 2 EE IIT, Kharagpur 1 Lesson 8 Measurement of Level, Humidity and ph Version 2 EE IIT, Kharagpur 2 Instructional Objectives At the end of this lesson, the student will

More information

Automatic Gamma-Ray Equipment for Multiple Soil Physical Properties Measurements

Automatic Gamma-Ray Equipment for Multiple Soil Physical Properties Measurements Automatic Gamma-Ray Equipment for Multiple Soil Physical Properties Measurements Carlos Manoel Pedro Vaz Embrapa Agricultural Instrumentation, São Carlos, Brazil Lecture given at the College on Soil Physics

More information

δ 13 C of DIC and carbonate samples: comparison of traditional mass spectrometry methods with an infrared spectrometry method

δ 13 C of DIC and carbonate samples: comparison of traditional mass spectrometry methods with an infrared spectrometry method APPLICATION NOTE 30486 δ 13 C of DIC and carbonate samples: comparison of traditional mass spectrometry methods with an infrared spectrometry method Authors Danijela Smajgl, 1 Magda Mandic, 1 Dirk Nürnberg,

More information

2012 AP CHEMISTRY FREE-RESPONSE QUESTIONS

2012 AP CHEMISTRY FREE-RESPONSE QUESTIONS 01 AP CHEMISTRY FREE-RESPONSE QUESTIONS. A sample of a pure, gaseous hydrocarbon is introduced into a previously evacuated rigid 1.00 L vessel. The pressure of the gas is 0.00 atm at a temperature of 17C.

More information

X-CELL Analytical. Petroleum Fluids Analysis. St. Francis Xavier University Analytical Services Lab. Equipment Specification Brochure

X-CELL Analytical. Petroleum Fluids Analysis. St. Francis Xavier University Analytical Services Lab. Equipment Specification Brochure X-CELL Analytical Petroleum Fluids Analysis St. Francis Xavier University Analytical Services Lab Equipment Specification Brochure Physical Sciences Center PO Box 5000 Antigonish, NS, B2G 2W5 Canada Phone:

More information

Experiment 7: ACID-BASE TITRATION: STANDARDIZATION OF A SOLUTION

Experiment 7: ACID-BASE TITRATION: STANDARDIZATION OF A SOLUTION Experiment 7: ACID-BASE TITRATION: STANDARDIZATION OF A SOLUTION Purpose: Determine molarity of a solution of unknown concentration by performing acid-base titrations Performance Goals: Apply the concepts

More information

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect Microscanner D-Series The Only Certified Accurate Surface Instruments in the World A MUST FOR ISO 9001 ISO 9002 ISO 9003 TRACEABILITY PROGRAMS Common Surface Measurement Errors D501 and D501-RS Microscanner

More information

Certificate of Analysis

Certificate of Analysis Certificate of Analysis Reference Standard 4,5α-Epoxy-14-hydroxy-3-methoxymorphinan-6-one Hydrochloride (Noroxycodone Hydrochloride) Catalogue Number: MM0672.03 Molecular Formula: C 17 H 19 NO 4 HCl Molecular

More information

(A) Simple distillation (i) When liquid sample has (i) Mixture of chloroform

(A) Simple distillation (i) When liquid sample has (i) Mixture of chloroform PURIFICATION METHODS Distillation Techniques : Ty p e C ondi ti ons E x a m p l e s (A) Simple distillation (i) When liquid sample has (i) Mixture of chloroform non volatile impurities (BP = 334K) and

More information

Addition of n-butyllithium to an Aldimine: On the Role of Chelation, Aggregation, and Cooperative Solvation

Addition of n-butyllithium to an Aldimine: On the Role of Chelation, Aggregation, and Cooperative Solvation Addition of n-butyllithium to an Aldimine: On the Role of Chelation, Aggregation, and Cooperative Solvation Bo Qu and David B. Collum* Department of Chemistry and Chemical Biology Baker Laboratory, Cornell

More information

Sensor Guide WS100 Radar Precipitation Sensor

Sensor Guide WS100 Radar Precipitation Sensor Abbeon Cal, Inc., 1363 Donlon Street Unit 1, Ventura, CA 93003-8387 - 800-922-0977 www.abbeon.com - E-mail: abbeoncal@abbeon.com Sensor Guide WS100 Radar Precipitation Sensor October 2017 Sensor Guide:

More information

Determining Moisture Content of Hay and Forages using Multiple Frequency Parallel Plate Capacitors

Determining Moisture Content of Hay and Forages using Multiple Frequency Parallel Plate Capacitors Agricultural and Biosystems Engineering Conference Proceedings and Presentations Agricultural and Biosystems Engineering 2001 Determining Moisture Content of Hay and Forages using Multiple Frequency Parallel

More information

Supplementary Figure 1. Structures of substrates tested with 1. Only one enantiomer is shown.

Supplementary Figure 1. Structures of substrates tested with 1. Only one enantiomer is shown. Supplementary Figure 1. Structures of substrates tested with 1. Only one enantiomer is shown. Supplementary Figure 2. CD spectra obtained using 1 and (R)-3 (blue) and (S)-3 (red) Supplementary Figure 3.

More information