Technical Data. Analytical Data

Size: px
Start display at page:

Download "Technical Data. Analytical Data"

Transcription

1 Technical Data Fast Method Scouting for Chiral Separation Utilizing CHIRAL ART s Chiral method optimization of ionic compounds utilizing immobilized type column in reversed phase mode Analytical Data -CBZ-DL-Alanine P. DL-Aoglutethimide P. Atropine P., 6 Benzoin P. 6,'-Binaphthyl-,'-diae P. 6,'-Binaphthyl-,'-diyl Bis(trifluoromethanesulfonate) P. 7,6-Bis(4-isopropyl--oxazolin--yl)pyridine P. 7,-Bis[(-methoxyphenyl)phenylphosphino]ethane P. 7,6-Bis(4-phenyl--oxazolin--yl)pyridine P. 8 Cetirizine (Levocetirizine) P. 8 Chloroquine P. 8 3,3'-Dibromo-,'-bi--naphthol P. 9 3,3'-Dibromo-,',6,6',7,7',8,8'-octahydro-,'-bi-- P. 9 aphthol,'-dimethoxy-,'-binaphthyl P. 9 Donepezil P. 9, Duloxetine hydrochloride P. Fenoprofen P. Flurbiprofen P. Hexobarbital P. Hydroxychloroquine P. Ibuprofen P.,'-Isopropylidenebis(4-phenyl--oxazoline) P. Ketae hydrochloride P. Ketoprofen P. Ketrolac P. Lansoprazole P. 3 DL-Mandelic acid P. 3 Metoprolol P. 3, 4 floxacin (Levofloxacin) P. 4 Phenoxybenzae P. 4 -CBZ-DL-Phenylalanine P. 4 Pindolol P. Propranolol P. Rabeprazole P. Sertraline hydrochloride P. 6 trans-stilbene oxide P. 6,,-Trifluoro--(9-anthryl)ethanol P. 6 Trimebutine P. 7 Troger s base P. 7 Valsartan P. 7 Verapamil P. 7 Warfarin P. 8 Zopiclone P. 8 Please see APPLICATI DATA SFC for applications of chiral compounds using SFC.

2 DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SA-HEX- MTBE_HCQ SA3.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SB-HEX- MTBE- HCQC Q HEX_MTBE4.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SC -HEX- MTBE- HCQC Q HCQ_HEX-IPA-F8.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SA-HEX- MTBE_HCQ _4_SA.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SB-HEX- MTBE- HCQC Q _4_HEX_MTBE64.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SC -HEX- MTBE- HCQC Q _3_HCQ_HEX- ET- F8.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SA-HEX- MTBE_HCQ _8_SA37.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SB-HEX- MTBE- HCQC Q _8_HEX_MTBE43.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SC -HEX- MTBE- HCQC Q _7_HCQ_MTBE-IPA-F 8.D ) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SA-HEX- MTBE_HCQ _6_SA9.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SB-HEX- MTBE- HCQC Q _6_HEX_MTBE3.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SA-ACET-IPA- HCQC Q HCQ_ACET-IPA- F8.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SB-ACET-HC QCQ _3_H CQ_AC ET-IPA-F8.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SC -HEX- MTBE- HCQC Q HCQ_MTBE-ET-F8.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SC -ACET-HC QCQ _3_H CQ_AC ET-IPA-F8.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SA-ACET-HC QCQ _3_H CQ_AC ET-ET-F 8.D ) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SB-ACET-HC QCQ H CQ_AC ET-ET-F 8.D ) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SC -ACET-HC QCQ H CQ_AC ET-ET- F8.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SA-CH3C -HC Q HCQ- M_C-ET-F 8.D ) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SB-CH3C -HC Q HCQ- M_C-ET-F 8.D ) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SC -CH3C-HC Q HCQ-M_C-ET- F8.D) -... DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SA-P-ET-H CQCQ HCQ_ME- ET -F8.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SB-P-H CQCQ _7_HCQ_ME- ET- F8.D) DAD E, Sig=344,6 Ref=4, (D: CHIRAL-SCREEIG SC -P-H CQCQ _7_HCQ_ME- ET -F8.D) Fast Method Scouting for Chiral Separation Utilizing CHIRAL ART s R43AE CHIRAL ART are HPLC columns with polysaccharide derivatives chiral selector, and are suitable for separations of wide range of chiral compounds. n CHIRAL ART Immobilized type with high solvent versatility, chromatographers can freely choose the most suitable mobile phase by considering the solubility and resolution of the target compounds. The excellent separation of various racemic compounds was achieved through fast method scouting utilizing the short columns and 3 µm CHIRAL ART immobilized type with three different chiral selectors. Method scouting Scouting protocol CHIRAL ART 3 μm, X 3. mmi.d. Amylose-SA Cellulose-SB Cellulose-SC P normal phase mode P 3 3 polar organic mode Mobile phase A B Additive 4 n-hexane MTBE ethyl acetate A acetonitrile methanol t-butyl methyl ether -propanol ethanol Gradient -% B B ethanol Gradient -% B Acidic compounds TFA, Acetic acid, Formic acid, etc. Basic compounds DEA, Butylae, Ethanolae, etc. Zwitterionic compounds Both or either of acidic additive and basic additive onionic compounds one 4 usually.% (upper limit.%) diethylae Experimental Matrix mode P P A n-hexane MTBE ethyl acetate acetonitrile methanol B -propanol ethanol -propanol ethanol -propanol ethanol ethanol ethanol additive.% DEA column Amylose-SA Select Cellulose-SC Cellulose-SB H Hydroxychloroquine : 3 µm, X 3. mmi.d. :.8 ml/ Gradient : %B (-. ), -%B (.-. ), %B (.-. ) for normal phase mode : %B (-. ), -%B (.-. ), %B (.-. ) for polar organic mode Temperature : : UV at 6, 9, 334 nm : µl ( mg/ml) The baseline resolution is achieved under four conditions in the method scouting for hydroxychloroquine. The combination of Amylose-SA phase and MTBE/ethanol containing.% DEA is selected as the most favorable condition in consideration of retention and resolution.

3 Separation results under simple isocratic conditions optimized through scouting of each compound The combination of the short columns packed with three types of 3 µm particles and the rapid gradient elution of eight types of ormal Phase (P) and Polar rganic (P) mobile phase are employed for separation method scouting of pharmaceutical compounds below. The selected conditions from scouting with gradient elution for each compound are convertedd to the isocratic elution methods and optimized. H S H Hydroxychloroquine meprazole Rabeprazole Lansoprazole Pindolol S H F F F S H H H Hydroxychloroquine α.6 Rs meprazole α.6 Rs.4 4 Rabeprazol α.8 Rs FD FJ F66G : CHIRAL ART Amylose-SA 3 µm, X 3. mmi.d. : A) MTBE/DEA (/.) B) ethanol/dea (/.) %B :.8 ml/ Temperature : : UV at 344 nm : µl ( µg/ml) : CHIRAL ART Amylose-SA 3 µm, X 3. mmi.d. : A) ethyl acetate/dea (/.) B) ethanol/dea (/.) %B :.8 ml/ Temperature : : UV at 9 nm : µl ( µg/ml) : CHIRAL ART Cellulose-SC 3 µm, X 3. mmi.d. : A) ethyl acetate/dea (/.) B) -propanol/dea (/.) %B :.8 ml/ Temperature : : UV at 9 nm : µl ( µg/ml) Lansoprazole α.7 Pindolol α 3. Pindolol (P mode) α.6 8 Rs. 4 Rs 4. 8 Rs FL FG FP : CHIRAL ART Amylose-SA 3 µm, X 3. mmi.d. Eluen : A) ethyl acetate/dea (/.) B) ethanol/dea (/.) %B :.8 ml/ Temperature : : UV at 9 nm : µl ( µg/ml) : CHIRAL ART Cellulose-SB 3 µm, X 3. mmi.d. : A) n-hexane/dea (/.) B) ethanol/dea (/.) 6%B :.8 ml/ Temperature : : UV at 6 nm : µl ( µg/ml) : CHIRAL ART Cellulose-SB 3 µm, X 3. mmi.d. : methanol/dea (/.) :.8 ml/ Temperature : : UV at 6 nm : µl ( µg/ml) DEA: diethylae The fast method development chiral separations is allowed through the method scouting. The selected conditions from scouting with gradient elution for each compound are converted to the isocratic elution methods and optimized to achieve the ultra-fast separation method within utes.

4 Chiral method optimization of ionic compounds utilizing immobilized type column in reversed phase mode ~ Influence of ph on retention behavior ~ Features of immobilized type columns F478AE Immobilized type CHIRAL ART columns can be used with various solvents that are commonly used for HPLC analysis. They can be used in both normal phase mode and reversed phase mode as they are compatible with non-aqueous and aqueous solvents (). Reversed phase mode will be effective in case where a sample is hydrophilic and has limited solubility in organic solvent (e. g. Hexane). In this technical data sheet, we will introduce influence of ph of mobile phase on retention behavior of ionic compounds. We also introduce several example of chiral separation on reversed phase mode. Specifications (Immobilized type) /Packing material Particle size (mm) CHIRAL ART Amylose-SA 3 CHIRAL ART Cellulose-SB CHIRAL ART Cellulose-SC Usable mobile phase ormal phase Reversed phase Chiral selector Amylose tris(3,-dimethylphenylcarbamate) Cellulose tris(3,-dimethylphenylcarbamate) Cellulose tris(3,-dichlorophenylcarbamate) Usable ph range.-9. Temperature range Pressure limit ~4 MPa n-hexane, n-heptane, methanol, ethanol, -propanol, acetonitrile, ethyl acetate, tetrahydrofuran, chloroform, t-butyl methyl ether, etc. acetonitrile, methanol, ethanol, -propanol, tetrahydrofuran, water, aqueous buffer, etc. Tips for optimizing chiral separation method of ionic compounds on reversed phase mode Mobile phase > ptimal ph that ionization of analyte is suppressed is recommended. (Retention will be extended and possibility of greater resolution is expected.) > Immobilized type CHIRAL ART columns are the best option. Reversed phase analyses with optimized separation methods Warfarin (pka.6) : CHIRAL ART Cellulose-SB : mm phosphoric acid (ph.)/ acetonitorile (/) F477A Donepezil (pka 8.6) : YMC CHIRAL Cellulose-SB : mm H 4 HC 3 -DEA (ph 9.)/ acetonitrile (4/6) F468A

5 Retention behavior of acid compound on reversed phase mode Influence of ph on retention behavior ph. ph _.D Warfarin (pka.6) : CHIRAL ART Cellulose-SB µm X 4.6 mmi.d. : mm phosphate buffer/acetonitrile (/) :. ml/ Temperature : : UV at 4 nm : µl (. mg/ml) 469_.D ph Retention of Warfarin ph 4.6 ph _.D 469_3.D Peak shape may deteriorated at around pka value of the compound Retention factor (k') 3... k' () k' () 46_.D ph ph 7. 46_4.D For acidic compound, retention is extended and good separation is achieved when decreasing the ph of a mobile phase (ionization was suppressed). Retention behavior of basic compound on reversed phase mode Influence of ph on retention behavior ph _.D Donepezil (pka 8.6) : CHIRAL ART Cellulose-SB µm X 4.6 mmi.d. : mm phosphate buffer/acetonitrile (4/6) :. ml/ Temperature : : UV at 4 nm : µl (. mg/ml) ph 6. Retention of Donepezil 47_.D 4. ph 7. ph 8. _4_467_6.D Retention factor (k') 3... k' () k' () ph 8.9 _3_467_3.D ph _6.D For basic compound, retention is extended and good separation is achieved when increasing the ph of a mobile phase (ionization was suppressed). 4

6 HPLC Analytical Data -CBZ-DL- アラニン -CBZ-DL-Alanine D89C -CBZ-DL- アラニン -CBZ-DL-Alanine V8E H α. Rs.4 4 L H α 3. L Rs 6.4 D D : CHIRAL ART Amylose-C eo ( µm) X 4.6 mmi.d. : n-hexane/-propanol/tfa (8//.) :. ml/ Temperature : : UV at 4 nm : µl ( mg/ml) : CHIRAL ART Cellulose-C ( µm) X 4.6 mmi.d. : n-hexane/-propanol/tfa (8//.) :. ml/ Temperature : : UV at 4 nm : µl ( mg/ml) DL- アミノグルテチミド DL-Aoglutethimide H78F アトロピン Atropine H38C CH3 H H78F α. Rs : CHIRAL ART Cellulose-SJ ( µm) X 4.6 mml.d. : n-hexane/ethyl acetate/diethylae (7//.) :. ml/ Temperature : : UV at 4 nm : µl ( mg/ml) : CHIRAL ART Amylose-C ( µm) X 4.6 mmi.d. : n-hexane/ethanol/ethanolae (87/3/.) :. ml/ Temperature : : UV at nm : µl ( mg/ml)

7 6 アトロピン Atropine H39C ベンゾイン Benzoin V9B CH3 H 6 α.93 Rs. 4 α.3 Rs : CHIRAL ART Cellulose-C ( µm) X 4.6 mmi.d. : n-hexane/ethanol/ethanolae (9//.) :. ml/ Temperature : : UV at nm : µl ( mg/ml) : CHIRAL ART Amylose-C ( µm) X 4.6 mmi.d. : n-hexane/-propanol (9/) :. ml/ Temperature : : UV at 4 nm : µl (. mg/ml) ベンゾイン Benzoin V8F,'- ビナフチル -,'- ジアミン,'-Binaphthyl-,'-diae E78V 7 4 (R)-(+) (R)-(+) H H H H (S)-(-) (S)-(-) 7 α.6 α.9 Rs. Rs : CHIRAL ART Cellulose-C ( µm) X 4.6 mmi.d. : n-hexane/-propanol (9/) :. ml/ Temperature : : UV at 4 nm : µl (. mg/ml) : CHIRAL ART Amylose-SA ( µm) X 4.6 mmi.d. : n-hexane/-propanol (/) :. ml/ Temperature : : UV at 4 nm : µl (. mg/ml) Sample : Supplied by Tokyo Chemical Industry Co., Ltd.

8 7,'- ビナフチル -,'- ジイルビス ( トリフルオロメタンスルホナート ),'-Binaphthyl-,'-diyl Bis(trifluoromethanesulfonate) E79B,6- ビス (4- イソプロピル -- オキサゾリン -- イル ) ピリジン,6-Bis(4-isopropyl--oxazolin--yl)pyridine E777B α. Rs.8 (R)-(-) (S)-(+) (R)-(-) (S)-(+) S CF 3 S CF 3 S CF 3 S CF 3 7 α.6 Rs 7.6 (R, R) (S, S) CH CH (R, R) CH CH (S, S) : CHIRAL ART Cellulose-SB ( µm) X 4.6 mmi.d. : n-hexane/methyl tert-butyl ether (/) :. ml/ Temperature : : UV at 8 nm : µl (. mg/ml) Sample : Supplied by Tokyo Chemical Industry Co., Ltd. : CHIRAL ART Cellulose-C ( µm) X 4.6 mmi.d. : n-hexane/-propanol (6/4) :. ml/ Temperature : : UV at 8 nm : µl (. mg/ml) Sample : Supplied by Tokyo Chemical Industry Co., Ltd.,- ビス [(- メトキシフェニル ) フェニルホスフィノ ] エタン,-Bis[(-methoxyphenyl)phenylphosphino]ethane T8B,-ビス [(-メトキシフェニル) フェニルホスフィノ ] エタン,-Bis[(-methoxyphenyl)phenyl-phosphino]ethane H78E α.9 Rs.9 PCH CH P 9 8 (R, R) (R, R) ma 7 6 (S, S) PCH CH P 7 4 (S, S) : CHIRAL ART Amylose-C eo ( µm) X 4.6 mmi.d. : n-hexane/-propanol (9/) :. ml/ Temperature : : UV at 8 nm : µl (. mg/ml) : CHIRAL ART Cellulose-SJ ( µm) X 4.6 mml.d. : n-hexane/chloroform (8/) :. ml/ Temperature : : UV at 9 nm : µl (. mg/ml)

9 ,6- ビス (4- フェニル -- オキサゾリン -- イル ) ピリジン,6-Bis(4-phenyl--oxazolin--yl)pyridine E78B セチリジン ( レボセチリジン ) Cetirizine (Levocetirizine) F4A 4 (R, R) α.3 Rs 3. (S)-Cetirizine (R, R) (S, S) (S, S) (R)-Cetirizine (Levocetirizine) α.7 Rs 9. : CHIRAL ART Cellulose-C ( µm) X 4.6 mmi.d. : n-hexane/ethanol (4/6) :. ml/ Temperature : : UV at 8 nm : µl (. mg/ml) Sample : Supplied by Tokyo Chemical Industry Co., Ltd. : CHIRAL ART Cellulose-C ( µm) X 4.6 mmi.d. : n-hexane/-propanol/formic acid/diethylae (7//./.) :. ml/ Temperature : : UV at nm : µl ( µg/ml) セチリジン ( レボセチリジン ) Cetirizine(Levocetirizine) F84C クロロキン Chloroquine F46C 6 H 3 4 (S)-Cetirizine (R)-Cetirizine (Levocetirizine) α. Rs.4 α.4 Rs : CHIRAL ART Cellulose-SB (3 µm) X 4.6 mmi.d. : acetonitrile/formic acid/diethylae (/./.) :. ml/ Temperature : : UV at nm : µl ( µg/ml) : CHIRAL ART Amylose-SA ( µm) X 4.6 mmi.d. : MTBE/ethanol/diethylae (9//.) :. ml/ Temperature : : UV at 344 nm : µl ( µg/ml) methyl tert-butyl ether 8

10 9 3,3 - ジブロモ -, - ビ -- ナフトール 3,3'-Dibromo-,'-bi--naphthol E78Q Br 3,3 - ジブロモ -,,6,6,7,7,8,8 - オクタヒドロ -, - ビ -- ナフトール 3,3'-Dibromo-,',6,6',7,7',8,8'-octahydro-,'-bi--naphthol E78S Br (S) (S) Br (S)-(-) (S)-(-) Br Br Br (R) (R)-(+) (R) Br Br (R)-(+) α.4 Rs.4 α.8 Rs : CHIRAL ART Amylose-SA ( µm) X 4.6 mmi.d. : n-hexane/ethanol (7/) :. ml/ Temperature : : UV at 8 nm : µl (. mg/ml) : CHIRAL ART Amylose-SA ( µm) X 4.6 mmi.d. : n-hexane/-propanol (7/) :. ml/ Temperature : : UV at 9 nm : µl (. mg/ml), - ジメトキシ -, - ビナフチル,'-Dimethoxy-,'-binaphthyl E78P ドネペジル Donepezil F34B (R) (S) (R) (S) α.3 Rs 4.7 α. Rs : CHIRAL ART Cellulose-SB ( µm) X 4.6 mmi.d. : n-hexane/-propanol (9/) :. ml/ Temperature : : UV at nm : µl (. mg/ml) : CHIRAL ART Cellulose-C ( µm) X 4.6 mmi.d. : n-hexane/ethanol/ethylenediae (8//.) :. ml/ Temperature : : UV at 7 nm : µl ( µg/ml)

11 ドネペジル Donepezil F477A デュロキセチン塩酸塩 Duloxetine hydrochloride F33A 4 H CH Duloxetine hydrochloride ((S)-Duloxetine hydrochloride) S H CH3 4 α. Rs 3. 4 Duloxetine related compound A ((R)-Duloxetine hydrochloride) S : CHIRAL ART Cellulose-SB ( µm) X 4.6 mmi.d. : mm H 4 HC 3 -diethylae (ph 9.)/acetonitrile (4/6) :. ml/ Temperature : : UV at 4 nm : µl ( µg/ml) : CHIRAL ART Amylose-C ( µm) X 4.6 mmi.d. : n-hexane/ethanol/diethylae (9//.) :. ml/ Temperature : : UV at nm : µl (. mg/ml) デュロキセチン塩酸塩 ( 米国薬局方記載条件 ) Duloxetine hydrochloride (The United States Pharmacopeia) F9A フェノプロフェン Fenoprofen V47B System suitability solution (. mg/ml Duloxetine hydrochloride,. mg/ml Duloxetine related compound A) 8 6 System suitability Result requirement Resolution (, ) Tailing factor (Duloxetine).8 ~.. Tailing factor (Duloxetine related compound A).8 ~.. H 4 α. Rs 3. S 4 Duloxetine hydrochloride ((S)-Duloxetine hydrochloride) H CH3 S Duloxetine related compound A ((R)-Duloxetine hydrochloride) V47B : CHIRAL ART Cellulose-C ( µm) X 4.6 mmi.d. : n-hexane/-propranol/diethylae (83/7/.) :. ml/ Temperature : 4 : UV at nm : µl (The United States Pharmacopeia 37th; Limit of Duloxetine related compound A) System suitability solution was prepared from duloxetine hydrochloride and duloxetine related compound A supplied as reagents for laboratory use. : CHIRAL ART Amylose-SA ( µm) X 4.6 mmi.d. : n-hexane/-propanol/tfa (9//.) :. ml/ Temperature : : UV at 4 nm : µl (. mg/ml)

12 フルルビプロフェン Flurbiprofen V47C ヘキソバルビタール Hexobarbital 6C α.3 Rs. 4 F V47C : CHIRAL ART Amylose-SA ( µm) X 4.6 mmi.d. : n-hexane/-propanol/tfa (9//.) :. ml/ Temperature : : UV at 4 nm : µl (. mg/ml) : YMC CHIRAL EA (R) X 4.6 mmi.d. : acetonitrile/water (/7) :.7 ml/ Temperature : ambient : UV at nm : µl (. mg/ml) ヒドロキシクロロキン Hydroxychloroquine F46A イブプロフェン Ibuprofen V4D 4 H α. Rs α.7 Rs. 6 4 V4D : CHIRAL ART Amylose-SA ( µm) X 4.6 mmi.d. : MTBE/ethanol/diethylae (9//.) :. ml/ Temperature : : UV at 344 nm : µl ( µg/ml) methyl tert-butyl ether : CHIRAL ART Cellulose-SB ( µm) X 4.6 mmi.d. : n-hexane/-propanol/tfa (99//.) :. ml/ Temperature : : UV at nm : µl ( mg/ml)

13 ,'- イソプロピリデンビス (4- フェニル -- オキサゾリン ),'-Isopropylidenebis(4-phenyl--oxazoline) T8F 塩酸ケタミン Ketae hydrochloride 6F CH CH C 3 C 3 H 4 4 (S, S). (S, S) (R, R) α 3. Rs 6.3 (R, R) : CHIRAL ART Amylose-C eo ( µm) X 4.6 mmi.d. : n-hexane/-propanol (7/) :. ml/ Temperature : : UV at nm : µl (. mg/ml) : YMC CHIRAL EA (R) X 4.6 mmi.d. : acetonitrile/. M a 4 (4/6) :. ml/ Temperature : ambient : UV at 68 nm : µl (.4 mg/ml) ケトプロフェン Ketoprofen V69K ケトロラック Ketrolac H78D α. Rs V69K : CHIRAL ART Cellulose-SC ( µm) X 4.6 mmi.d. : n-hexane/-propanol/tfa (9//.) :. ml/ Temperature : : UV at 4 nm : µl (. mg/ml) : CHIRAL ART Cellulose-SJ ( µm) X 4.6 mml.d. : n-hexane/tetrahydrofuran/tfa (7//.) :. ml/ Temperature : : UV at nm : µl (. mg/ml)

14 3 ランソプラゾール Lansoprazole F6B DL- マンデル酸 DL-Mandelic acid V97A F F F S H 8 7 H 6 4 α. Rs.4 α. Rs : CHIRAL ART Amylose-SA ( µm) X 4.6 mmi.d. : ethyl acetate/ethanol/diethylae (9//.) :. ml/ Temperature : : UV at 9 nm : µl ( µg/ml) : CHIRAL ART Amylose-C ( µm) X 4.6 mmi.d. : n-hexane/-propanol/tfa (8//.) :. ml/ Temperature : : UV at 4 nm : µl ( mg/ml) DL- マンデル酸 DL-Mandelic acid V97B メトプロロール Metoprolol H38D H H α.4 Rs α. Rs : CHIRAL ART Cellulose-C ( µm) X 4.6 mmi.d. : n-hexane/-propanol/tfa (8//.) :. ml/ Temperature : : UV at 4 nm : µl ( mg/ml) : CHIRAL ART Amylose-C ( µm) X 4.6 mmi.d. : n-hexane/ethanol/ethanolae (8//.) :. ml/ Temperature : : UV at 4 nm : µl ( mg/ml)

15 4 メトプロロール Metoprolol H39B オフロキサシン ( レボフロキサシン ) floxacin (Levofloxacin) F39A H H F 8 (S)-(-)-floxacin (Levofloxacin) 6 α.3 H F α. Rs. 4 Rs 4. (R)-(+)-floxacin : CHIRAL ART Cellulose-C ( µm) X 4.6 mmi.d. : n-hexane/ethanol/ethanolae (9//.) :. ml/ Temperature : : UV at 4 nm : µl ( mg/ml) : CHIRAL ART Cellulose-SC ( µm) X 4.6 mmi.d. : MTBE/ethanol/acetic acid/ethylenediae (//./.) :. ml/ Temperature : 4 : UV at nm : µl ( µg/ml) methyl tert-butyl ether フェノキシベンザミン Phenoxybenzae H77D -CBZ-DL- フェニルアラニン -CBZ-DL-Phenylalanine V43U 6 H 4 4 α.4 Rs.9 α.4 Rs 4.4 H77D3 KSJ V43U : CHIRAL ART Cellulose-SJ ( µm) X 4.6 mml.d. : n-hexane/ethanol/diethylae (9//.) :. ml/ Temperature : : UV at 7 nm : µl ( mg/ml) : CHIRAL ART Cellulose-SC ( µm) X 4.6 mmi.d. : n-hexane/-propanol/tfa (8//.) :. ml/ Temperature : : UV at 4 nm : µl ( mg/ml)

16 ピンドロール Pindolol F3C ピンドロール Pindolol F6A H H H H α. Rs 4. α. Rs : CHIRAL ART Cellulose-SB ( µm) X 4.6 mmi.d. : methanol/diethylae (/.) :. ml/ Temperature : : UV at 6 nm : µl ( µg/ml) : CHIRAL ART Cellulose-SB ( µm) X 4.6 mmi.d. : n-hexane/ethanol/diethylae (4/6/.) :. ml/ Temperature : : UV at 6 nm : µl ( µg/ml) プロプラノロール Propranolol V86A ラベプラゾール Rabeprazole F36A 4 H 4 S H α. Rs.6 α.9 Rs : CHIRAL ART Cellulose-C ( µm) X 4.6 mmi.d. : n-hexane/-propanol/diethylae (8//.) :. ml/ Temperature : : UV at nm : µl (. mg/ml) : CHIRAL ART Cellulose-SC ( µm) X 4.6 mmi.d. : ethyl acetate/-propanol/diethylae (9//.) :. ml/ Temperature : : UV at 9 nm : µl ( µg/ml)

17 6 セルトラリン塩酸塩 ( 欧州薬局方記載条件 ) Sertraline hydrochloride (The European Pharmacopoeia) (A) Reference solution (a) (6.8 mg/ml Sertraline for system suitability CRS) 7 (B) Test solution (6. mg/ml Sertraline hydrochloride) 7 E3C E36A (C) Reference solution (b) (.3 mg/ml Sertraline hydrochloride) E3A E36B Test solution and Reference solution were prepared from Sertraline hydrochloride supplied as a reagent for laboratory use. H H H Sertraline hydrochloride H H H Sertraline hydrochloride (enantiomer) : CHIRAL ART Amylose-C ( µm) X 4.6 mmi.d. : mixture /n-hexane (7/) :.4 ml/ Temperature : : UV at 7 nm : µl (The draft for The European Pharmacopoeia; Enantiomeric purity) n-hexane/-propanol/diethylae (97//) トランススチルベンオキサイド trans-stilbene oxide (+)-R,R-trans-Stilbene oxide,3,-tri-tert-butylbenzene (. mg/ml, t marker) : CHIRAL ART Amylose-C eo ( µm) X 4.6 mmi.d. : n-hexane/-propanol (9/) :. ml/ Temperature : : UV at nm : µl (. mg/ml) D89B (-)-S,S-trans-Stilbene oxide α 3. Rs 3.4 トランススチルベンオキサイド trans-stilbene oxide V8D トリフルオロアンスリルエタノール,,-Trifluoro--(9-anthryl)ethanol H78C 4 (+)-R,R-trans-Stilbene oxide 4 (-)-S,S-trans-Stilbene oxide α.3 Rs : CHIRAL ART Cellulose-C ( µm) X 4.6 mmi.d. : n-hexane/-propanol (9/) :. ml/ Temperature : : UV at nm : µl (. mg/ml) : CHIRAL ART Cellulose-SJ ( µm) X 4.6 mml.d. : n-hexane/tetrahydrofuran (9/) :. ml/ Temperature : : UV at 4 nm : µl (. mg/ml)

18 トリメブチン Trimebutine H77E トレガー塩基 Troger s base V63H α.3 Rs. 7 α.43 Rs H77E3 KSJ V63H.... : CHIRAL ART Cellulose-SJ ( µm) X 4.6 mml.d. : n-hexane/ethanol/diethylae (9//.) :. ml/ Temperature : : UV at 6 nm : CHIRAL ART Amylose-SA ( µm) X 4.6 mmi.d. : n-hexane/ethanol (9/) :. ml/ Temperature : : UV at 4 nm : µl (. mg/ml) バルサルタン ( 米国薬局方記載条件 ) Valsartan (The United States Pharmacopeia) E6B ベラパミル Verapamil V9D Test solution (. mg/ml Valsartan) H C H H 4 α.3 Rs 4. 7 Valsartan C H H 8 9 H E6B Valsartan enantiomer (Valsartan related compound A) : CHIRAL ART Cellulose-C ( µm) X 4.6 mmi.d. : n-hexane/-propanol/tfa (8//.) :.8 ml/ Temperature : : UV at nm : µl (The United States Pharmacopeia 34th; Related compounds) : CHIRAL ART Amylose-C ( µm) X 4.6 mmi.d. : n-hexane/-propanol/diethylae (9//.) :. ml/ Temperature : : UV at 4 nm : µl ( mg/ml) 7 Test solution was prepared from Valsartan supplied as a reagent for laboratory use.

19 8 ワルファリン Warfarin F468A ゾピクロン Zopiclone F79D Extracted ion chromatograms (m/z 389. > 4.) E7 Spiked hair (. ng/mg each) H (R)-Zopiclone α. Rs 7.3 Relative abundance 3 4 H (S)-Zopiclone (Eszopiclone) : CHIRAL ART Cellulose-SB ( µm) X 4.6 mmi.d. : acetonitrile/ mm phosphoric acid (/) :. ml/ Temperature : : UV at 4 nm : µl ( µg/ml) Courtesy of H. Miyaguchi, ational Research Institute of Police Science. J.Chromatogr. A 9 (7) -63. : CHIRAL ART Cellulose-SC (3 µm) X. mmi.d. : mm ammonium bicarbonate (ph 8. with aqueous ammonia)/acetonitrile (/7) :. ml/ Temperature : : ESI, positive : µl (Hair sample extracted by micropulverized extraction) Instrument : LC) Ultimate TM liquid chromatograph (Thermo Fisher Scientific) HRMS) Q Exactive TM mass spectrometer (Thermo Fisher Scientific)

20 89AE

Optical Isomer Separation Columns and Packing Materials

Optical Isomer Separation Columns and Packing Materials 02 Optical Isomer Separation s and Packing Materials CHIRAL ART----------------------------------- 26~29 YMC CHIRAL NEA (R), (S)-----------------------30 YMC CHIRAL CD BR------------------------------31

More information

TCI Chiral HPLC Column

TCI Chiral HPLC Column TCI Chiral HPLC Column ~ Helical Polymer New Chiral Stationary Phase ~ Tokyo Chemical Industry Co.,Ltd. 212 Tokyo Chemical Industry Co., Ltd. Features of TCI Chiral A unique new stationary phase Polymaleimide

More information

Chiral separations efficient, fast and productive

Chiral separations efficient, fast and productive Chiral separations efficient, fast and productive By Per Jageland*, Mattias Bengtsson and Kristina Hallman AkzoNobel Eka Chemicals AB, Separation Products SE 445 80 Bohus Sweden Introduction Chromatographic

More information

ChromegaChiral TM CSP Media and Columns

ChromegaChiral TM CSP Media and Columns ChromegaChiral TM CSP Media and Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

Method Development for Chiral LC/MS/MS Analysis of Acidic Stereoisomeric Pharmaceutical Compounds with Polysaccharide-based Stationary Phases

Method Development for Chiral LC/MS/MS Analysis of Acidic Stereoisomeric Pharmaceutical Compounds with Polysaccharide-based Stationary Phases Method Development for Chiral LC/MS/MS Analysis of Acidic Stereoisomeric Pharmaceutical Compounds with Polysaccharide-based Stationary Phases Liming Peng, Swapna Jayapalan, and Tivadar Farkas Phenomenex,

More information

LC-MS compatible Separation of the Fungicide Spiroxamine

LC-MS compatible Separation of the Fungicide Spiroxamine Spiroxamine is a systemic fungicide, which was brought to the market by Bayer CropScience. The substance is a mixture of diastereomers A and B again consisting of 4 enantiomers A1, A2, B1 and B2 (fig.

More information

APPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate)

APPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate) T-1079 APPLICATI Method Development for Reversed Phase Chiral LC/M/M Analysis of tereoisomeric Pharmaceutical Compounds with Polysaccharide-based tationary Phases Philip J. Koerner, Kari Carlson, Liming

More information

6 Optical Isomer Separation Columns

6 Optical Isomer Separation Columns YMC GENERAL CATALG ptical Isomer Separation Columns YMC CHIRAL CD BR series YMC CHIRAL NEA YMC CHIRAL PREP CD ST/PM 128,129 13,131 132,133 127 第 章.indd 127 11.1.28 1:57:24 AM ptical isomer structural isomer

More information

ChromegaChiral TM CSP Media and Columns

ChromegaChiral TM CSP Media and Columns ChromegaChiral TM CSP Media and Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate)

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate) T-147 APPLICATIS Alternative Selectivity of Chiral Stationary Phases Based on Cellulose tris(3-chloro-4-methylphenylcarbamate) and Cellulose tris(3,5-dimethylphenylcarbamate) Liming Peng, Tivadar Farkas

More information

Chiral Separation Using SFC and HPLC

Chiral Separation Using SFC and HPLC PO-CON6E Chiral Separation Using and HPLC Pittcon 06 760-6 Satoru Watanabe, Hidetoshi Terada, Takato Uchikata, Yohei Arao, Kenichiro Tanaka, Yasuhiro Funada Shimadzu Corporation, Kyoto, Japan; Shimadzu

More information

New 3-Micron Polysaccharide-based Chiral Columns for Fast HPLC and SFC Geoffrey B. Cox, Norbert M. Maier Chiral Technologies, Inc

New 3-Micron Polysaccharide-based Chiral Columns for Fast HPLC and SFC Geoffrey B. Cox, Norbert M. Maier Chiral Technologies, Inc New 3-Micron Polysaccharide-based Chiral Columns for Fast HPLC and SFC Geoffrey B. Cox, Norbert M. Maier Chiral Technologies, Inc Pilar Franco and Tong Zhang Chiral Technologies, Europe Benefits of 3-Micron

More information

INSTRUCTION MANUAL FOR CHIRALPAK ZWIX(+) and CHIRALPAK ZWIX(-)

INSTRUCTION MANUAL FOR CHIRALPAK ZWIX(+) and CHIRALPAK ZWIX(-) 800 orth Five Points Road West Chester, PA 19380 800 6 CIRAL Tel: 610-594-2100 Fax: 610-594-2325 chiral@chiraltech.com www.chiraltech.com ISTRUCTI MAUAL FR CIRALPAK ZWIX(+) and CIRALPAK ZWIX(-) Semi-Preparative

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India Effective use of pharmacopeia guidelines to reduce cost of chromatographic analysis Optimized, cost-effective HPLC analysis of atorvastatin by varying column dimensions within the USP allowed limts

More information

LUMEFANTRINUM LUMEFANTRINE

LUMEFANTRINUM LUMEFANTRINE July 2008 LUMEFANTRINE: Final text for addition to The International Pharmacopoeia (July 2008) This monograph was adopted at the Forty-second WHO Expert Committee on Specifications for Pharmaceutical Preparations

More information

FAQ's. 1 - Which column would be the most appropriate for my application?

FAQ's. 1 - Which column would be the most appropriate for my application? 1 - Which column would be the most appropriate for my application? Due to the complexity of the chiral recognition mechanism, it is not possible yet to establish rules for the selection of the best chiral

More information

Application Note. Authors. Abstract. Pharmaceuticals

Application Note. Authors. Abstract. Pharmaceuticals Enantiomer separation of nonsteroidal anti-inflammatory drugs Using Daicel immobilized polysaccharide-derived chiral columns and the Agilent 1260 Infinity Analytical SFC System Application Note Pharmaceuticals

More information

Reversed Phase Solvents

Reversed Phase Solvents Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography

More information

Choosing Columns and Conditions for the Best Peak Shape

Choosing Columns and Conditions for the Best Peak Shape Choosing Columns and Conditions for the Best Peak Shape What is Good Peak Shape and Why is it Important? Good peak shape can be defined as a symmetrical or gaussian peak and poor peak shape can include

More information

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing

More information

Basic Principles for Purification Using Supercritical Fluid Chromatography

Basic Principles for Purification Using Supercritical Fluid Chromatography Basic Principles for Purification Using Supercritical Fluid Chromatography Jo-Ann M. Jablonski, Christopher J. Hudalla, Kenneth J. Fountain, Steven M. Collier, and Damian Morrison Waters Corporation, Milford,

More information

C18 Column. Care & Use Sheet

C18 Column. Care & Use Sheet C18 Column Care & Use Sheet HALO Description HALO C18 is a high-speed, high-performance liquid chromatography column based on a new Fused-CoreTM particle design. The Fused-Core particle provides a thin

More information

Capacity vs Throughput on Modified Macrocylics in Reversed Phase, Polar Ionic Mode and Normal Phase

Capacity vs Throughput on Modified Macrocylics in Reversed Phase, Polar Ionic Mode and Normal Phase Capacity vs Throughput on Modified Macrocylics in Reversed Phase, Polar Ionic Mode and Normal Phase Denise Wallworth, J T Lee & Thomas E Beesley, Advanced Separation Technologies Chromatographic Society

More information

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Analysis - HPLC A.136. Primesep 5 µm columns B.136 Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using

More information

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide Supported Liquid Extraction (SLE) Guide and FAQ s User Guide What is SLE? Supported Liquid Extraction (SLE) is an extraction technique that separates out compounds based on their affinity for one solvent

More information

mau 200 ph min

mau 200 ph min mau ph - 6 8 TAKE A LOOK INSIDE TWIN Technology TWIN (Two-In-One ) Technology is what gives Gei its superior performance edge. During the final stage of silica manufacturing, a unique silica-organic layer

More information

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode HILIC-1 Column for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N

More information

Chiral Method Development in LC/MS Using Macrocyclic Glycopeptide CSPs

Chiral Method Development in LC/MS Using Macrocyclic Glycopeptide CSPs Chiral Method Development in LC/MS Using Macrocyclic Glycopeptide CSPs J. T. Lee 1, T. E. Beesley 1, Meera Desai 2 1 Advanced Separation Technologies Inc. (astec) 37 Leslie Court, P.. Box 297 Whippany,

More information

Modernizing the USP Monograph for Acetaminophen

Modernizing the USP Monograph for Acetaminophen Modernizing the USP Monograph for cetaophen pplication Note Small Molecule Pharmaceuticals and Generics uthor Rongjie Fu gilent Technologies (Shanghai) Co. Ltd bstract new HPLC method was developed for

More information

ADVANTAME. Not less than 97.0% and not more than 102.0% on the anhydrous basis. Sweetener, flavour enhancer

ADVANTAME. Not less than 97.0% and not more than 102.0% on the anhydrous basis. Sweetener, flavour enhancer ADVANTAME SYNONYMS INS No. 969 Prepared at the 80 th JECFA (2015), published in FAO JECFA Monographs 17 (2015), superseding tentative specifications prepared at 77 th JECFA (2013). An ADI of 0-5 mg/kg

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

Column handling. Information. 1 Introduction 2 Shipping solvent. 3 Mobile phase. 4 Mobile phase replacement and column cleaning (general methods)

Column handling. Information. 1 Introduction 2 Shipping solvent. 3 Mobile phase. 4 Mobile phase replacement and column cleaning (general methods) Column handling-------------------------------- 194 Mobile phases for ODS columns ----------- 195 HPLC column performance ------------------ 196 Inspection reports ------------------------------ 197 Basic

More information

Dilution(*) Chromatography

Dilution(*) Chromatography WA20264 Poster # 184, HPLC 2002, Montreal, 4-5 June 2002 At-Column Column-Dilution for Preparative Dilution(*) Chromatography Cecilia Mazza, Jie Cavanaugh, Ziling Lu,Tom Sirard,Tom Wheat and Uwe Neue Waters

More information

Do you need trouble-free speed? The NEW Chromolith HR

Do you need trouble-free speed? The NEW Chromolith HR Do you need trouble-free speed? The NEW Chromolith HR EMD Millipore is a division of Merck KGaA, Darmstadt, Germany ... then speed-up to Chromolith HighResolution... Revolutionary monolithic silica columns

More information

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46> High Performance Liquid Chromatography HPLC-9 Ultra-high Speed Analysis of Ibuprofen within USP Allowed Limits by Nexera Method Scouting In recent years, high-throughput analytical techniques have

More information

Nexera UC Unified Chromatography

Nexera UC Unified Chromatography Nexera UC Unified Chromatography The latest addition to the chromatography toolbox Dr. Gesa J. Schad Shimadzu Europa GmbH A brief history of SFC ϒ Late 1800 s: it was found that heavy, non-volatile organic

More information

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India Reducing analysis time and solvent consumption for isocratic USP assay methods with current and proposed USP guidelines using the Agilent 129 Infinity LC System An efficient way to reduce cost of analysis

More information

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster Welcome to our E-Sear: Choosing HPLC Columns for Faster Analysis Smaller and Faster High Throughput/Fast LC Requires. Short columns 0 mm or shorter Small particle sizes. µm Rapid Resolution or new.8 µm

More information

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS Richard Jack, Xiaodong Liu, Leo Wang, and Chris Pohl OT70806_E 08/13S 1 The world leader in serving science

More information

Practicing Chiral Chromatography in Your Mobile Phase Comfort Zone

Practicing Chiral Chromatography in Your Mobile Phase Comfort Zone Practicing Chiral Chromatography in Your Mobile Phase Comfort Zone Enantiomers Stereoisomers that differ in the direction they rotate a plane of polarized light are called optically active, or chiral,

More information

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases Agilent 129 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases Technical Overview Author A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany Abstract The Agilent

More information

CHIRAL STATIONARY PHASES

CHIRAL STATIONARY PHASES CIRAL STATIARY PASES CIRAL STATIARY PASES Chiral Chromatography Chirality has become vitally important in the pharmaceutical, chemical and agricultural industries. The differences which make compounds

More information

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for Clinical Toxicology Page of 0 Materials and Methods Biomass Component Extraction: The uneaten cooked plant specimen was prepared for chemical analysis as follows. The sample was frozen, diced, pulverized

More information

Do you need trouble-free speed? The NEW Chromolith HR

Do you need trouble-free speed? The NEW Chromolith HR Do you need trouble-free speed? The NEW Chromolith HR EMD Millipore is a division of Merck KGaA, Darmstadt, Germany ... then speed-up to Chromolith HighResolution... Revolutionary monolithic silica columns

More information

Fast methods for the determination of ibuprofen in drug products

Fast methods for the determination of ibuprofen in drug products APPLICATION NOTE 779 Fast s for the determination of ibuprofen in drug products Authors Sylvia Grosse, Mauro De Pra, Frank Steiner, Thermo Fisher Scientific, Germering, Germany Keywords Pharmaceutical,

More information

TCI Dual ~Mixed-Mode Mode column~

TCI Dual ~Mixed-Mode Mode column~ TCI Dual ~Mixed-Mode Mode column~ TCI Chromatography Department Mixed-Mode Column Target compound is basic Choose DS + Cation-Exchange Type Target compound is acidic Choose DS + Anion-Exchange Type o ion-pair

More information

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials

More information

It s hot! ZIC -chilic

It s hot! ZIC -chilic It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits

More information

GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI

GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI syringe filters promises reproducible results from the filtration of organic and aqueous solutions in HPLC. Trace amount of samples containing impurities or contaminants can be easily removed, resulting

More information

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Carmen T. Santasania and David S. Bell Supelco 595 N. Harrison Rd., Bellefonte, PA 16823 T403168 GJU Introduction Stationary phases based

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

Chiral Columns for enantiomer separation by HPLC

Chiral Columns for enantiomer separation by HPLC Chiral Columns for enantiomer separation by HPLC SUMICHIRAL OA columns are high-performance chiral columns for enantiomer separation by HPLC. On SUMICHIRAL OA columns direct separation of various enantiomers

More information

Simultaneous estimation of amitryptyline and chlordiazepoxide by RP-HPLC method

Simultaneous estimation of amitryptyline and chlordiazepoxide by RP-HPLC method IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page: ISSN: 2320-2831 Research article Open Access Simultaneous estimation of amitryptyline and chlordiazepoxide by RP-HPLC method Dr.R.Srinivasan*, K.Lurdhu

More information

Reversed Phase Chromatography: Mobile phase Considerations

Reversed Phase Chromatography: Mobile phase Considerations Reversed Phase: Mobile Phase Considerations Dr. www.forumsci.co.il/hplc Example of a Reversed Phase Method with UV Detection 1 Chromatographic Process B+A Mobile phase Elution through the Column-movie

More information

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent

More information

William E. Barber, Ph.D. Applications Chemist October

William E. Barber, Ph.D. Applications Chemist October William E. Barber, Ph.D. Applications Chemist ctober 0 00 Secrets of Good Peak Shape in HPLC Time: :00 p.m. CET Telephone Number: + 44 0 76 088 Chairperson: John Vis The Secrets of Good Peak Shape in HPLC

More information

Scaling Up to Preparative Chromatography

Scaling Up to Preparative Chromatography Scaling Up to Preparative Chromatography Dr. Shulamit Levin home page: www.forumsci.co.il/hplc Strategy for Preparative Separation Selection of the appropriate mode of chromatography ptimization of the

More information

CYCLOSERINE Final text for addition to The International Pharmacopoeia. (November 2008) CYCLOSERINUM CYCLOSERINE

CYCLOSERINE Final text for addition to The International Pharmacopoeia. (November 2008) CYCLOSERINUM CYCLOSERINE December 2008 CYCLOSERINE Final text for addition to The International Pharmacopoeia (November 2008) This monograph was adopted at the Forty-third WHO Expert Committee on Specifications for Pharmaceutical

More information

Handling Products. Sumitomo Chemical Co., Ltd. SUMICHIRAL ~192

Handling Products. Sumitomo Chemical Co., Ltd. SUMICHIRAL ~192 15 Sumitomo Chemical Co., Ltd. SUMICHIRAL ------------------------------ 188~192 YMC_GC_Vol12_15_CS4.indd 187 15/09/24 9:49 15 Chiral columns for enantiomer separation by HPLC [SUMICHIRAL OA] *SUMICHIRAL

More information

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under on-extreme Mobile Phase Conditions Richard A. Henry, Shawn R. Wyatt, Carmen T. Santasania and David S. Bell

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

MEDROXYPROGESTERONE INJECTION

MEDROXYPROGESTERONE INJECTION September 2011 RESTRICTED DRAFT PROPOSAL FOR The International Pharmacopoeia MEDROXYPROGESTERONE INJECTION (September 2011) DRAFT FOR COMMENT Should you have any comments on the attached draft proposal,

More information

Effects of Aqueous Sample Content and Aqueous Co-Solvent Composition on UPC 2 Separation Performance

Effects of Aqueous Sample Content and Aqueous Co-Solvent Composition on UPC 2 Separation Performance Effects of Aqueous Sample Content and Aqueous Co-Solvent Composition on UPC 2 Separation Performance Christopher Knappy, 1 Norman W Smith, 1 Arundhuti Sen, 1 Paul D Rainville, 2 and Robert S Plumb 2 1

More information

Dissolution Test 5 was validated using a Zodiac C18 brand of L1 column. The typical retention time for atorvastatin is about min.

Dissolution Test 5 was validated using a Zodiac C18 brand of L1 column. The typical retention time for atorvastatin is about min. Atorvastatin Calcium Tablets Type of Posting Posting Date 25 Jan 2019 Official Date 01 Feb 2019 Expert Committee Chemical Medicines Monographs 2 Reason for Revision Compliance In accordance with the Rules

More information

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS Application Note Traditional Chinese Medicine Author Rongjie Fu Agilent Technologies

More information

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China Rapid Deteration of Eight Related Aromatic Acids in the p-phthalic Acid Mother Liquid Using an Agilent 126 Infinity LC System and an Agilent Poroshell 12 SB-C18 Column Application Note Author Xinlei Yang

More information

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 2 PFP Columns Application ote Small Molecule Pharmaceuticals Authors Rongjie Fu Agilent Technologies (Shanghai) Co., Ltd Linhai Zhang

More information

HPLC solvents and mobile phase additives

HPLC solvents and mobile phase additives HPLC solvents and mobile phase additives The following is intended to be a guide for the choice of solvent and mobile phase additives. Of course the choice of solvents for LC will be dictated primarily

More information

Overcome Top Challenges in Analytical Method Development and Validation

Overcome Top Challenges in Analytical Method Development and Validation Overcome Top Challenges in Analytical Method Development and Validation Q. Chan Li, Ph.D. Analytical Development US, Boehringer Ingelheim Pharmaceuticals, Inc. IVT Analytical Method Validation, San Diego,

More information

Trefoil Columns [ CARE AND USE MANUAL ] CONTENTS I. INTRODUCTION I. INTRODUCTION GETTING STARTED III. COLUMN USE IV.

Trefoil Columns [ CARE AND USE MANUAL ] CONTENTS I. INTRODUCTION I. INTRODUCTION GETTING STARTED III. COLUMN USE IV. CNTENTS I. INTRDUCTIN II. GETTING STARTED a. Safety Considerations b. Column Connectors and Installation c. ecord Installation d. Column Equilibration e. Initial Column Efficiency Determination III. CLUMN

More information

Comparison of different aqueous mobile phase HPLC techniques

Comparison of different aqueous mobile phase HPLC techniques June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active

More information

Acclaim Mixed-Mode WCX-1

Acclaim Mixed-Mode WCX-1 Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)

More information

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time Thermo Scientific Syncronis HPLC Columns Remarkable separations guaranteed time after time Syncronis HPLC and UHPLC Columns Remarkable separations guaranteed time after time When developing a new method,

More information

Acclaim HILIC-10 Columns

Acclaim HILIC-10 Columns Thermo Scientific Acclaim HILIC- Columns Product Manual P/N: January 3 Part of Thermo Fisher Scientific Product Manual for Acclaim HILIC- Analytical Column Acclaim HILIC-, 3 µm, Analytical, 4.6 x 5 mm

More information

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs Value of Eclipse Plus C18 and ph Selectivity to Analyze Ae-Containing Drugs Application Pharmaceuticals Authors John W. Henderson Jr., William J. Long, and Cliff Woodward Agilent Technologies 285 Centerville

More information

for Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode WCX-1 for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm

More information

Eliminating Unwanted Variability in LC Methods: More Uptime, More Sample Throughput

Eliminating Unwanted Variability in LC Methods: More Uptime, More Sample Throughput Eliminating Unwanted Variability in LC Methods: More Uptime, More Sample Throughput HPLC Separation Robustness and Ruggedness Group/Presentation Title June 20, Agilent 2017Month Restricted ##, 200X Page

More information

Analytical Chiral SFC. Application Guide 1

Analytical Chiral SFC. Application Guide 1 Analytical Chiral SFC Application Guide 1 Introduction In the 1960s, University of Utah Professor J. Calvin Giddings discovered the phenomenon of supercritical fluid chromatography (SFC). Nearly 20 years

More information

A Pre-Clinical Pharmacokinetic-Pharmacodynamic Modelling and Biodistribution Studies of Donepezil Hydrochloride by Validated HPLC Method

A Pre-Clinical Pharmacokinetic-Pharmacodynamic Modelling and Biodistribution Studies of Donepezil Hydrochloride by Validated HPLC Method Electronic Supplementary Material (ESI) for RSC Advances. This journal is The Royal Society of Chemistry 2018 A Pre-Clinical Pharmacokinetic-Pharmacodynamic Modelling and Biodistribution Studies of Donepezil

More information

Supporting Information

Supporting Information Supporting Information S1 Reversible stereodivergent cycloaddition of racemic helicenes to [60]fullerene: a chiral resolution strategy Rosa M. Girón, Jiangkun Ouyang, Ludovic Favereau, Nicolas Vanthuyne,

More information

Primesep TM. Solving Problems of Pharmaceutical HPLC Analysis. Creating New Dimensions in the World of Chromatography.

Primesep TM. Solving Problems of Pharmaceutical HPLC Analysis. Creating New Dimensions in the World of Chromatography. Primesep TM Solving Problems of Pharmaceutical HPLC Analysis Creating ew Dimensions in the World of Chromatography www.primesep.com Content Introduction ovel stationary phase properties Retention of polar

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending Patent pending Website : www.chromtech.net.au E-mail : info@chromtech.net.au telno : 0 97 0... in AUSTRALIA A Novel Bonding Technique (patent pending) An unique trifunctional silyl-reagent was developed

More information

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column Application Note 95 Determination of Hydrochloride Purity Using the Acclaim PA Column INTRODUCTION -based medications are prescribed for several heart and blood pressure indications. The fastacting formulations

More information

Too Polar for Reversed Phase What Do You Do?

Too Polar for Reversed Phase What Do You Do? Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer

More information

8. Methods in Developing Mobile Phase Condition for C18 Column

8. Methods in Developing Mobile Phase Condition for C18 Column I. HPLC Columns Technical Information 8. Methods in Developing Mobile Phase Condition for C18 Column Introduction In reversed phase HPLC, octadecyl group bonded silica columns (C18, ODS) are the most widely

More information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Thermo Scientific Accucore XL HPLC Columns. Technical Manual Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users

More information

Evaluation of an HPLC Chiral Separation Flow Scheme for Small Molecules

Evaluation of an HPLC Chiral Separation Flow Scheme for Small Molecules Journal of Liquid Chromatography & Related Technologies w, 31: 629 666, 2008 Copyright # Taylor & Francis Group, LLC ISSN 1082-6076 print/1520-572x online DOI: 10.1080/10826070701853693 Evaluation of an

More information

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 Cogent HPLC Columns Manufactured by Table of Contents QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 C8 Bidentate C8 Extremely long

More information

Determination of Pharmaceuticals in Environmental Samples

Determination of Pharmaceuticals in Environmental Samples Determination of Pharmaceuticals in Environmental Samples BACKGROUND The full effects of pharmaceutical substances in the environment are largely unknown however the risk is significant enough that many

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb

More information

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

Application. Authors. Abstract. Introduction. Hydrocarbon Processing Fast Analysis Method for Rubber Chemical Antidegradants Using Rapid Resolution Liquid Chromatography (RRLC) Systems with Rapid Resolution High Throughput (RRHT) Columns Application Hydrocarbon Processing

More information

The Theory of HPLC. Ion Pair Chromatography

The Theory of HPLC. Ion Pair Chromatography The Theory of HPLC Ion Pair Chromatography i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual.

More information

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY CHAPTER 9 DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY CHAPTER 9 Determination of drug release during

More information

SEPARATION OF FLURBIPROFEN AND IBUPROFEN ENANTIOMERS ON A CHIRAL STATIONARY PHASE USING SUPERCRITICAL FLUIDS

SEPARATION OF FLURBIPROFEN AND IBUPROFEN ENANTIOMERS ON A CHIRAL STATIONARY PHASE USING SUPERCRITICAL FLUIDS SEPARATION OF FLURBIPROFEN AND IBUPROFEN ENANTIOMERS ON A CHIRAL STATIONARY PHASE USING SUPERCRITICAL FLUIDS John Whelan, Mickey Martin, Raquel Carvallo, Sermin G. Sunol, Aydin K. Sunol* Chemical Engineering

More information

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20544 Key Words Hydrophilic, HILIC,

More information