GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI
|
|
- Tabitha Wood
- 5 years ago
- Views:
Transcription
1 syringe filters promises reproducible results from the filtration of organic and aqueous solutions in HPLC. Trace amount of samples containing impurities or contaminants can be easily removed, resulting in extending the lifetime of an HPLC analytical column. Usage Type Description and Ion-Chromato 4A 13A 25A 4A 13A 25A 13S 4P 13P 25P 4N 13N 4N 13N 4AI 13AI 25AI Composed of hydrophilic polyolefine membrane and polypropylene housing. Ideal for use in water and alcoholic solution targeted for sample preparation of protein analysis. This is a type that a chromatodisc and a syringe are combined. Composed of hydrophilic PTFE and polypropylene housing. Can be used without any pre-wet treatment for hydrophilics and hydrophobics. Acetonitrile 100% solution can be used. Solvents that can be used are alcohols, ethers, esters, ketones, hexanes. Autoclave sterilization is applicable. Composed of PTFE membrane and polypropylene housing. Excellent in solvent and chemical resistance. Therefore, it is ideal for use in organic solvents, strong acids, strong alkalis targeted for sample preparation of microanalysis. Autoclave sterilization is applicable. Composed of hydrophilic polyolefine membrane and polypropylene housing, which is treated by deionization. Ideal for use in sample preparation for ion chromatograph analysis. Type A Type P Type N
2 syringe filter for & samples Used for filtration of & samples Name 4P 13P 25P Fluorinated polymer membrane is used. & hydrophobic samples can be used without any pre-wetted treatment. Up to a 100% acetonitrile can be used. Ideal for filtration of alcohols, ethers, esters, ketones, and hexanes. polytetrafluoroethylene (PTFE) Size 4mm 13mm 25mm Size 8ψ x 18 18ψ x 22 29ψ x 24 Size 1mL 0.5 ~10mL 3~50mL M.A.O.P. 7kgf/cm2 5kgf/cm2 6kgf/cm2 Ethylene oxide gas / Autoclave Pore Size (μm) Cat. No syringe filter for samples Used for filtration of s Name 4A 13A 13S 25A Ideal for pretreatment of water and alcohol solution in HPLC and protein analysis.. membrane (Olefin polymer) Size 4mm 13mm 13mm 25mm Size 8ψ x 18 18ψ x 22 18ψ x 94 29ψ x 24 With a syringe Size 1mL 0.5 ~10mL 3~50mL Hold-UP Volume 10μL 30μL 30μL 100μL E.F.A. 0.07cm2 0.8cm2 0.8cm2 4.0cm2 M.A.O.P. 7kgf/cm2 5kgf/cm2 5kgf/cm2 6kgf/cm2 Ethelene oxide gas Pore Size (μm) Cat. No Pcs./Box
3 syringe filter for samples Used for filtration of s Name 4N 13N Superior chemical compatibility. Ideal for filtration of solvents, strong acids and alkali solution. Usable as a air-venting filter PTFE Size 4mm 13mm 25mm Size 8ψ x 18 18ψ x 22 29ψ x 24 Size 1mL 0.5 ~10mL 3~50mL M.A.O.P. 7 kgf/cm2 5 kgf/cm2 6 kgf/cm2 Ethylene oxide gas / Autoclave Pore Size (μm) Cat. No syringe filter for Ion-Chromatography samples Used for filtration of Ion chromatography s Name 4AI 13AI 25AI Deionized hydrophilic membrane is used. Ideal for filtration of ion chromatography samples Deionized membrane (Olefin polymer) Size 4mm 13mm 25mm Size 8ψ x 18 18ψ x 22 29ψ x 24 Size 1mL 0.5 ~10mL 3~50mL M.A.O.P. 7 kgf/cm2 5 kgf/cm2 6 kgf/cm2 Ethylene oxide gas Pore Size 0.45μm 0.45μm 0.45μm Cat. No
4 Chemical Resistance Information TYPE A : / Ion Chromatography O Enable TYPE P : / Enable but only for rapid use TYPE N : X Disable Chemical Name Chemical Description / Type A P N Acids Alkalis Alcohols Ethers Esters Glacial acetic acid Acetic acid 90% Acetic acid 30% O O Acetic acid 10% O O Hydrochloric acid Conc. X X X Hydrochloric acid 6N X O Sulfuric acid Conc. X X X Sulfuric acid 6N X O Nitric acid Conc. X X X Nitric acid 6N X O Ammonia 6N Ammonia 3N O O Potassium hydroxide 3N O O Sodium hydroxide 6N Sodium hydroxide 5N O O Sodium hydroxide 3N O O O Methanol O O O Ethanol O O O Propanol O O Isopropanol O O O Butanol O O O Amyl alcohol O O Ethylene glycol O O Propylene glycol O O Glycerin O O Ethyl ether O O O Isopropyl ether O O Dioxane X O O Tetrahydrofuran X O O Methyl acetate X O O Ethyl acetate X O O Isopropyl acetate X O Butyl acetate X O O
5 Ordering Information Usage Type Diameter (mm) Pore Size (um) Cat# QTY. 4A pcs pcs 13A pcs pcs 25A pcs pcs 13S pcs & 4P pcs 13P pcs pcs 25P pcs Ion-Chromato 4N 4 13N AI 4 13AI 13 25AI pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs GL Sciences, Inc. Japan 22-1 Nishishinjuku 6-Chome Shinjuku-ku, Tokyo, , Japan Phone: FAX: world@gls.co.jp GL Sciences, Inc. USA 4733 Torrance Blvd. Suite 255 Torrance, CA Phone: FAX: info@glsciencesinc.com International Distributors Visit our Website at
N6,6 Posidyne Membranes
Rev. Date: 20-Jun-2010 Ultipor Nylon 6,6 and N6,6 Posidyne Membrane Description Pall provides a complete range of Nylon 6,6 membranes for fluid filtration in the pharmaceutical, biotechnology, electronics,
More informationChemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder
Contact Us: www.pall.com/contact Chemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder Chemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder Introduction
More informationMicro Float-A-Lyzer READY-TO-USE MICRODIALYSIS DEVICES. Product Information & Operating Instructions
Spectra/Por Micro Float-A-yzer EADY-TO-USE MICODIAYSIS DEVICES Product Information & Operating Instructions Table of Contents Introduction....................................1 Applications...................................2
More informationMEMBREX. Ready-to-use Syringe Filters < 1 up to 100 ml. Minimizes Loss of Sample. Minimale Holdup-Volume. Low Adsorption.
MEMBREX < Ready-to-use Syringe Filters < 1 up to 100 ml Minimizes Loss of Sample Minimale Holdup-Volume Low Adsorption Optimized Shape MEMBREX Syringe filters Offering syringe filters in various shapes
More informationTube O Reactor. (Micro: Cat. # K, K, K) (Medi: Cat. # K, K, K)
453PR G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name Tube O Reactor (Micro: Cat. # 786 024 4K, 786 024 8K, 786 024 15K) (Medi: Cat. # 786
More informationSpectra/Por. Float-A-Lyzer READY-TO-USE DIALYSIS DEVICES. Product Information & Operating Instructions
Spectra/Por Float-A-yzer G2 EADY-TO-USE DIAYSIS DEVICES Product Information & Operating Instructions Table of Contents Introduction....................................1 Applications...................................2
More informationChemical Polyurethane Polyethelyne PVC Nylon 11 Kynar
ACETIC ACID, GLACIAL 4 2 4-1 ACETIC ACID, 30% 4 1 4 2 1 ACETONE 4 2 4 1 4 ACETYLENE 1 4 1 1 1 ALKAZENE 4 - - - - ALUMINUM CHLORIDE (aq) 3 2 1-1 ALUMINUM NITRATE (aq) 3-2 - 1 AMMONIA ANGYDROUS 4 2 1-4 AMMONIA
More informationTechnical data and operating instructions. Vivaspin 4. Vivaspin 4 10K device for in vitro diagnostic use
Technical data and operating instructions Vivaspin 4 Vivaspin 4 10K device for in vitro diagnostic use 85030-516-16 85030-516-16 Vivaspin 4 ml Introduction Storage conditions shelf life Vivaspin 4 ultrafiltration
More informationInertSustainSwift C8
HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which
More informationThermo Scientific Titan3 and Target2 Chromatography Syringe Filters. Performance filtration solutions. for sample preparation
Thermo Scientific Titan3 and Target2 Chromatography Syringe Filters Performance filtration solutions for sample preparation syringe filters Sample preparation is a key stage in successful chromatography.
More informationThis method describes the identification of the following prohibited colorants in cosmetic products:
A. IDENTIFICATION BY TLC 1. SCOPE AND FIELD OF APPLICATION This method describes the identification of the following prohibited colorants in cosmetic products: Names C I number Pigment Orange 5 12075 Metanil
More informationLaboratory filtration. Principles and chemical compatibility chart
Laboratory filtration Principles and chemical compatibility chart Filtration simplified Basic filtration concepts and terms Selecting a filter with the appropriate properties can help you achieve accurate
More informationstance et Helper Eppendorf Pipet Helper Chemical Resistance
stance et Helper Resistance N) Chemical Resistance Copyright 2017 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this publication may be reproduced without the prior
More informationThe best material for original Eppendorf Tubes and Plates: Properties and chemical resistance of polypropylene
APPLICATION NOTE No. 056 I June 2013 The best material for original Eppendorf Tubes and Plates: Properties and chemical resistance of polypropylene Natascha Weiß, Susanne Pruszkowski, Eppendorf AG, Hamburg,
More informationMulti-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for Sample Preparation
Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for ample Preparation -Instruction Manual- Table of Contents ection 1 Introduction...1 ection 2 Column Descriptions...2 ection 3 Instructions
More informationChemical Compatibility of Filter Components
Data Sheet Chemical Compatibility of Filter Components Compatibility of materials used in the construction of EMD Millipore products The tables on the following pages contain recommendations based solely
More informationProduct Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas
Agilent Porous Polymer PLOT Columns: New Products, Expanded Uses, Prices Cut in Half! Product Brief Need improved resolution of small volatile compounds? Didn't try a PLOT column due to high price, short
More informationSOLUZIONI PER L ENERGIA TERMICA THERMAL ENERGY SOLUTIONS
Table on chemical resistance of rubber materials Class 1 little or no effect Class 2 minor effect Class 3 moderate effect Class 4 severe effect Chemical Conc. Temp. EPDM NBR VITON % C Acetic acid 10 50
More informationVOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography
VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography Introduction ASTM International publishes a number of different methods for the determination of volatile compounds in water-based coatings.
More informationCation Exchange HPLC Columns
Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb
More informationShodex TM ODP2 HP series columns
HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series
More informationGlove Selection Chart
Glove Selection Chart The following guide is a general guide for glove selection in relation to chemicals handled. The information presented here is believed to be accurate; however, we cannot guarantee
More informationMaterials of Construction and Chemical Compatibility for Sensing and Control Products
ADVANCED MATERIALS HANDLING TECHNICAL NOTE Materials of Construction and Compatibility for Sensing and Control Products INTRODUCTION Entegris Sensing and Control products are designed for use in highly
More information8 Materials, Corrosion Resistance Tables
8 Materials, Corrosion Resistance Tables Included among the criteria for meter selection are the materials to be utilized. Of primary interest are those materials which come in contact with the measuring
More informationHalar ECTFE chemical resistance chart
Technical Information Halar ECTFE chemical resistance chart Introduction Halar ECTFE is one of the most chemically resistant polymers available today. This chemical resistance is due to the chemically
More informationIntroducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.
Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products. CHRISTOPHER M. ENGLISH, CHRISTOPHER S. COX, FRANK
More informationCellufine Butyl Cellufine Phenyl
Hydrophobic Interaction Chromatography Media Cellufine Butyl Cellufine Phenyl Technical Data Sheet 2-1, Otemachi 2-Chome Chiyoda-ku, Tokyo 100-8105 JAPAN Phone +81-3-3243-6150 Fax +81-3-3243-6219 e-mail:
More informationSPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods
How to Choose an SPE Product 1. Characterize the Sample Factors such as the analyte s polarity relative to the matrix, the presence of charged functional groups, solubility, molecular weight, etc., determine
More informationLC800. Smart HPLC. Until now UHPLC From now Smart HPLC
LC800 Smart HPLC Until now UHPLC From now Smart HPLC Smart HPLC Leads to Ultimate Performance Patent Pending S LC800 is a completely new and unique concept, designed for maximum performance in high resolution
More informationLATEST TECHNOLOGY IN Safe handling & Recovery OF Solvents in Pharma Industry
LATEST TECHNOLOGY IN Safe handling & Recovery OF Solvents in Pharma Industry TYPICAL SOLVENT USE IN Pharma Industry Usage of solvents in an API process development is for: Diluent to carry out reaction
More informationFerdowsi University of Mashhad
Spectroscopy in Inorganic Chemistry 2 Diatomic molecule C v and D h HCN H-H 3 contribution orbital electron Σ 0 σ 1 Π 1 π 1 Δ 2 δ 1 Φ 3 δ 1 Σ + Σ - 4 Linear molecule NO 2s+1 2 Π A 1 =Σ + 0 A 2 =Σ - 0 E
More informationAlcohols, Phenols and Ethers
SUBJECTIVE PROBLEMS: Alcohols, Phenols and Ethers Q1. An organic liquid (A), containing C, H and O with boiling point: 78 o C, and possessing a rather pleasant odour, on heating with concentrated sulphuric
More informationOptical Isomer Separation Columns and Packing Materials
02 Optical Isomer Separation s and Packing Materials CHIRAL ART----------------------------------- 26~29 YMC CHIRAL NEA (R), (S)-----------------------30 YMC CHIRAL CD BR------------------------------31
More informationAn alcohol is a compound obtained by substituting a hydoxyl group ( OH) for an H atom on a carbon atom of a hydrocarbon group.
Derivatives of Hydrocarbons A functional group is a reactive portion of a molecule that undergoes predictable reactions. All other organic compounds can be considered as derivatives of hydrocarbons (i.e.,
More informationSpectroscopy in Inorganic Chemistry. Electronic Absorption Spectroscopy
Spectroscopy in Inorganic Chemistry Diatomic molecule C v and D h NO H-H 2 contribution orbital Σ 0 σ Π 1 π Δ 2 δ Φ 3 δ 3 Linear molecule NO 2s+1 2 Π A 1 =Σ + 0 A 2 =Σ - 0 E 1 =Π 1 E 2 =Δ 2 E 3 =Φ 3 4
More informationAromatic Hydrocarbons
Aromatic Hydrocarbons Aromatic hydrocarbons contain six-membered rings of carbon atoms with alternating single and double carbon-carbon bonds. The ring is sometimes shown with a circle in the center instead
More informationHigh Purity Chromasolv Solvents
Research Chemicals High Purity Chromasolv Solvents Part of Honeywell Research Chemical s Exclusive Riedel-de Haën Brand Portfolio The Chromasolv family of solvents are used in a variety of analytical applications
More informationSwell Sheet Chemical Resistance Guide
Swell Sheet Chemical Resistance Guide MULTI-SWELL 3760 Rev. 3/2018 LEAK-GARD 3750 KEY: A - Ideal for low pressure applications B - Fair, Depends on conditions; please contact Applications Engineering C
More informationTAMMSFLEX SL / TAMMSFLEX NS
Acetic Acid, 10% 1 1 2 4 Acetic Acid, 50% 1 1 2 4 Acetic Acid, Glacial 1 4 - - Acetone 1 1 1 4 Acrylonitrile 2 4 - - Aluminum Sulfate(aq), 50% 1 1 1 1 Ammonium Chloride(aq), 50% 1 1 1 1 Ammonium Hydroxide(aq),
More informationPEROXIDE-FORMING CHEMICALS
XVIII. PEROXIDE-FORMING CHEMICALS Some common laboratory chemicals can form peroxides on exposure to air. Peroxides are shocksensitive and can be violently explosive in concentrated form or as solids.
More informationSafe Installation and Use of the NanoRam Immersion Probe
Safe Installation and Use of the NanoRam Immersion Probe Description: NanoRam Immersion Probe - 12 inch length; Immersion Probe Disposable Protective Sleeve Model Number: NR2-IMP; NR2-IMPS Part Number:
More informationPRODUCT DATA SHEET PDS A88_E
Plugs Suitable for A B C D Ref. Quantity Box/Bag (mm) (mm) (mm) (mm) TCP5 M12R + Pg7R M12R 4,5 8,5 10,8 4,5 3.000/100 TCP10 Pg9R Pg9R 6 12 12 4,5 2.000/100 TCP12 M12 + Pg7 M12 + Pg7 M16R + Pg11R M16R +
More informationCHEM 263 Oct 11, Lecture Outline 3: Alcohols, Ethers, Stereochemistry, Ketones, and Aldehydes. Ethanol
CEM 263 ct 11, 2016 Lecture utline 3: Alcohols, Ethers, Stereochemistry, Ketones, and Aldehydes Nomenclature of Alcohols Alcohols are compounds that have a hydroxyl group (-) bonded to a carbon atom (but
More informationDionex IonPac AS28-Fast-4µm column
CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS-Fast-4µm Columns Product Specifications The Thermo Scientific Dionex IonPac AS-Fast-4µm column is a high-capacity, hydroxide-selective anionexchange column
More informationHigh Performance Liquid Chromatography
Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN
More informationHigh Performance Liquid Chromatography
Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN
More informationNo.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page
No.106 Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series Contents Page 1. Introduction 2. Features 3. Basic characteristics 3-1. Pore characteristics 3-2. Sample injection volume
More informationgerflor.com.au Stain chemicals
gerflor.com.au Stain resistance: list of chemicals PRODUCTS/ TIME MIPOLAM TARALAY TARALAY / WALL CONCENTRATED ACID Acetic acid - CH 3 -COOH 14 0 0 0 0-1d 0-1d 0-1d 1d 1d 2d 0 0 0-1d Hydrochloric acid -
More informationSwell Sheet Chemical Resistance Guide
Swell Sheet Chemical Resistance Guide MULTI-SWELL 3760 Rev. 6/2016 LEAK-GARD 3750 KEY: A - Ideal for low pressure applications B - Fair, Depends on conditions; please contact Applications Engineering C
More informationCHEM 261 Dec 4, 2017
200 CEM 261 Dec 4, 2017 REVIEW: 1. N 3 2 S 4 1. 2 Al 3 N 2 2. 2 Al 3 2. N 3 2 S 4 N 2 I II For the left hand reaction, I - to create a meta positioned, the first molecule to be subsituted should be N 2,
More informationSafe Operating Procedure
Safe Operating Procedure (Reviewed 1/09) USE AND STORAGE OF PEROXIDE-FORMING CHEMICALS (For assistance, please contact EHS at (402) 472-4925, or visit our web site at http://ehs.unl.edu/) Some common laboratory
More informationMultistep Synthesis of 5-isopropyl-1,3-cyclohexanedione
Multistep Synthesis of 5-isopropyl-1,3-cyclohexanedione The purpose of this experiment was to synthesize 5-isopropyl-1,3-cyclohexanedione from commercially available compounds. To do this, acetone and
More informationChemistry 110. Bettelheim, Brown, Campbell & Farrell. Ninth Edition
Chemistry 110 Bettelheim, Brown, Campbell & Farrell Ninth Edition Introduction to General, rganic and Biochemistry Chapter 14 Alcohols, Ethers and Thiols Alcohols have a ydroxyl Group, -, bonded to tetrahedral
More informationChemical Storage According to Compatibility
Chemical Storage According to Compatibility To lessen risk of exposure to hazardous chemicals, all chemicals should be separated and stored according to hazard category and compatibility. *Storage Groups
More informationEppendorf UVette. Instructions for use
Instructions for use Instructions Eppendorf see Fig. Tab. p. p. UVette for use Copyright 2014 Eppendorf AG, Hamburg, Germany. All rights reserved, including graphics and images. No part of this publication
More informationAlltech Alltima HP Introduction
Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life
More informationHints for Strong Ion Exchange Resins
Hints for Strong Ion Exchange Resins Chromatography Application Note AN98 Abstract Ion exchange columns are a powerful means of isolating and purifying compounds, but their use is limited due to lack of
More informationPeek Chemical Resistance
Peek Chemical Resistance R = Resistant LR = Limited Resistance NR = Not Recommended ND = No Data Chemical Resistance 20 o C 60 o C 100 o C Acetaldehyde NR NR R Acetic acid (10%) R R R Acetic acid (glac./anh.)
More informationPRODUCT DATA SHEET PDS A112_E. Metric thread M 1.5 pitch CEI EN CEI EN 50262
reduced cable entry Metric thread M 1.5 pitch CEI EN 60423 CEI EN 50262 Ref. P Fixing A B C L Light Hole min-max Spanner min-max Quantity Grey (mm) (mm) (mm) (mm) (mm) 1910S.M16N M16x1,5 16,5 4-7,5 19
More informationLesmahagow High School
Lesmahagow High School Chemistry Advanced Higher Unit 1 Physical Chemistry TUTORIAL EXERCISES 1. Consider the equilibrium below: Unit 1 Physical Chemistry Tutorial 1.1 The Equilibrium Constant The equilibrium
More informationEgualen Sodium Granules
Egualen Sodium Granules Dissolution Weigh accurately an amount of Egualen Sodium Granules, equivalent to about 5 mg of egualen sodium (C 15 H 17 NaO 3 S 1/3 H2O) according to the labeled amount,
More informationAmicon Ultra-15 10K Centrifugal Filter Devices
User Guide Amicon Ultra-15 10K Centrifugal Filter Devices for volumes up to 15 ml UFC901008 UFC901024 UFC901096 C V English Introduction Amicon Ultra-15 10K centrifugal filter devices provide fast ultrafiltration,
More informationHeadspace Technology for GC and GC/MS: Features, benefits & applications
Headspace Technology for GC and GC/MS: Features, benefits & applications Karima Baudin Oct 2015 Why use Headspace? Very Simple no to minimum sample prep Robust enhance uptime Non-detectable carry-over
More informationA freely accessible HNS data base
Improving Member States preparedness to face an HNS pollution of the Marine System (HNS-MS) A freely accessible HNS data base The HNS data base in a nutshell 120 HNS, described by 90+ data covering 6 main
More informationDispensette S NEW! Bottle-top Dispenser. The New Generation! n New discharge tube. n New valve system. n Faster priming. n Less force needed during
The New Generation! Dispensette S Bottle-top Dispenser F I R S T C L A S S B R A N D Innovative ideas with trusted technology the new bottle-top dispenser. n New discharge tube with or without recirculation
More informationAppendix 5: table of chemical compatibility for tubing
Appendix 5: table of chemical compatibility for tubing KEY 1 Excellent 2 Good 3 Fair 4 Not recommended - no data Silicone PharMed Iso-Versinic PVC Acetaldehyde 3 4 4 2 Acetamide, 67% in w 1 2 4 4 Acetate
More informationPREVENTING HAZARDOUS WASTE FINES
University of Medicine and Dentistry of New Jersey EOHSS FACTSHEET PREVENTING HAZARDOUS WASTE FINES In the last few years institutions such as MIT, University of New Hampshire, Yale, Stanford, and Boston
More informationBELZONA PRODUCT DATA G504 CHEMICAL RESISTANCE OF BELZONA 5892
Alcohols, Aldehydes and Ketones Organic Acids Inorganic Acids BELZONA RODUCT DATA 504 CHEICAL RESISTANCE OF BELZONA 5892 10% * - Hydrochloric acid HCl 5% * - (647-01-0) 1% * - hosphoric acid (orthophosphoric
More informationSizes 48" x 96" (1.22m x 2.44m) Custom sheet sizes available upon request
Applications Decorative paneling Partitions Water features Signage Furniture Displays and more... Attributes Excellent UV properties High impact resistance - 17x greater than glass and 4x greater than
More informationDispensette S NEW! Bottle-top Dispenser. The New Generation! n New discharge tube. n New valve system. n Faster priming. n Less force needed during
The New Generation! Dispensette S Bottle-top Dispenser F I R S T C L A S S B R A N D Innovative ideas with trusted technology the new bottle-top dispenser. n New discharge tube with or without recirculation
More informationOptimizing GPC Separations
Optimizing GPC Separations Criteria for Solvent Selection True sample solubility (Polarity and Time dependant) Compatibility with columns Avoid non-size exclusion effects (eg adsorption by reverse phase
More informationProPac WCX-10 Columns
ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,
More informationLC and LC/MS Column Selection Flow Chart
LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the
More informationEnzymatic Assay of CARBOXYPEPTIDASE P (EC )
PRINCIPLE: N-CBZ-Glu-Tyrosine + H2O Carboxypeptidase P > N-CBZ-L-Glutamic Acid + L-Tyrosine Abbreviation used: N-CBZ = N-Carbobenzoxy CONDITIONS: T = 30 C, ph = 3.7, A 570nm, Light path = 1 cm METHOD:
More informationHow proteins separate on reverse-phase HPLC
1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP
More information3.0 Spiraltek Rolled Filters
3.0 Spiraltek Rolled Filters s of Construction Polypropylene Filter Core and Support Polypropylene Media (16.5 ft 2 ) Fiberglass Reinforced Polypropylene Encapsulation Valves of Polypropylene Valve Springs
More informationMass Spectral Studies of Polypropylene Chromatographic Well Plates
Mass Spectral Studies of Polypropylene Chromatographic Well Plates Brian King, Thermo Fisher Scientific, Runcorn, Cheshire, UK Detlev Lennartz, Thermo Fisher Scientific, Langerwehe, Germany White Paper
More information2017 Reaction of cinnamic acid chloride with ammonia to cinnamic acid amide
217 Reaction of cinnamic acid chloride with ammonia to cinnamic acid amide O O Cl NH 3 NH 2 C 9 H 7 ClO (166.6) (17.) C 9 H 9 NO (147.2) Classification Reaction types and substance classes reaction of
More informationgroups I and II cations, amines, divalent transition metals
IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,
More informationCHEMICAL RESISTANCE OF BELZONA 1523 FN10150
Organic Acids Inorganic Acids CHEICAL RESISTANCE OF BELZONA 1523 20% - Hydrochloric acid HCl 10% - 5% - (647-01-0) 3% - Nitric acid HNO 3 (7697-37-2) 10% - Nitrous acid HNO 2 (7782-77-6) 10% - hosphoric
More informationSafety Manual > Incompatible Chemicals Partial Listing
Safety Manual > Incompatible Chemicals Partial Listing C. Incompatible Chemicals Partial Listing Chemical Incompatible Chemicals Acetic acid Chromic acid, nitric acid, permanganates, and peroxides Acetic
More informationDesalting and Buffer Exchange with Corning Spin-X UFCentrifugal Concentrators
Desalting and Buffer Exchange with Corning Spin-X UFCentrifugal Concentrators Protocol Table 1. Maximum Recommended Maximum Volume and (Centrifugal Force) for Spin-X UF Concentrators Concentrator Spin-X
More informationALCOHOLS AND PHENOLS
Chem 306 Name Partner Section (Circle) M Tu W Th Date ALCOHOLS AND PHENOLS Purpose: In this laboratory activity you will investigate some chemical and physical properties of alcohols and phenols Introduction:
More informationGB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE
Translated English of Chinese Standard: GB5009.28-2016 www.chinesestandard.net Buy True-PDF Auto-delivery. Sales@ChineseStandard.net NATIONAL STANDARD OF THE GB PEOPLE S REPUBLIC OF CHINA GB 5009.28-2016
More informationGloves: choice and use
Gloves: choice and use Adopted April 15 th, 2003 Comité sectoriel de sécurité du Département de chimie Université Laval Wearing gloves: why? Gloves are worn for protection. However, gloves do not always
More information500 SERIES CHEMICAL RESISTANCE GUIDE
500 SERIES CHEMICAL RESISTANCE GUIDE INTRODUCTION The Stonchem 500 Series Chemical Resistance Guide is designed to aid in the proper selection of material for every job application. Exposure to over 250
More informationPreparation, analysis of samples in HPLC
Preparation, analysis of samples in HPLC Preparation, analysis of samples in HPLC Leader on the market of solvents for chromatography and trace analysis, Carlo Erba Réactifs-SdS extended its range of solvents
More informationTEPZZ 6ZA_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: C07D 401/06 ( )
(19) TEPZZ 6ZA_T (11) EP 3 112 360 A1 (12) EUROPEAN PATENT APPLICATION (43) Date of publication: 04.01.17 Bulletin 17/01 (1) Int Cl.: C07D 1/06 (06.01) (21) Application number: 1617780.2 (22) Date of filing:
More information1. Name the following compound. Use the IUPAC system and include the stereochemical designations.
Chemistry 51 Exam 1, Summer 2004 This is a closed book exam. The exam lasts 100 minutes. All answers must appear on the answer sheet. Only the answer sheet will be collected. Put your name on the answer
More informationOndansetron Hydrochloride Tablets
Ondansetron Hydrochloride Tablets Dissolution Perform the test with 1 tablet of Ondansetron Hydrochloride Tablets at 50 revolutions per minute according to the Paddle method, using 900 ml of water
More informationBackground on Solubility
CHEM254 01 Open Notebook Science Solubility Challenge 1 For the first laboratory exercise of this semester we are going to participate in the Open Notebook Science (ONS) solubility challenge http://onschallenge.wikispaces.com/.
More informationChemical Compatibility Guide Issue One
CNAF X Chemical Compatibility Guide Issue One Chemical Compatibility Guide Chieftain X, Centurion X, and Sentinel X compressed non asbestos fibre sheet gasket materials The following information is issued
More informationCHEMICAL RESISTANCE DATA FOR POLYETHYLENES
CHEMICAL RESISTANCE DATA FOR POLYETHYLENES [ R = Resistant LR= Low Resistance NR= Not Resistant] 23 o C 60 o C 23 o C 60 o C Acetaldehyde(100%) LR NR LR NR Acetic acid (10%) R R R R Acetic acid (50%) R
More informationSupporting Information
Supporting Information Wiley-VCH 2007 69451 Weinheim, Germany 1 Dihydrogen Reduction of Carboxylic Esters to Alcohols Catalyzed by Homogeneous Ruthenium Complexes: High Efficiency and Unprecedented Chemoselectivity.
More informationMEDROXYPROGESTERONE INJECTION
September 2011 RESTRICTED DRAFT PROPOSAL FOR The International Pharmacopoeia MEDROXYPROGESTERONE INJECTION (September 2011) DRAFT FOR COMMENT Should you have any comments on the attached draft proposal,
More informationPartial Periodic Table
CEM 3311, Fall 2011 Professor Walba Third our Exam November 17, 2011 scores: 1) 20 2) 20 3) 20 4) 20 5) 20 100 CU onor Code Pledge: n my honor, as a University of Colorado at Boulder tudent, I have neither
More informationFUNDERMAX GMBH TEST REPORT
FUNDERMAX GMBH TEST REPORT SCOPE OF WORK SEFA 3 2010, 2.1 Analysis of Max Compact Interior Plus White and Black Plaques REPORT NUMBER 103600635GRR 001a ISSUE DATE 25 September 2018 PAGES 22 DOCUMENT CONTROL
More informationHPLC Sample Preparation
HPLC Sample Preparation Rely on Sartorius solutions and benefit from optimized workflows for clean results mau 400 350 300 250 200 150 100 50 0 50 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0
More informationHAZARDOUS MATERIALS SURVEY. Note: List ALL virgin stock materials in current and projected inventories LAB NAME: PI: ADDRESS:
HAZARDOUS MATERIALS SURVEY Note: List ALL virgin stock materials in current and projected inventories LAB NAME: PI: ADDRESS: Please read each definition of the following Hazardous Materials carefully and
More informationAutomated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench
Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench Application Note Forensic Toxicology and Drug Testing Author Jared Bushey Agilent Technologies, Inc. 285 Centerville
More information