GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI

Size: px
Start display at page:

Download "GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI"

Transcription

1 syringe filters promises reproducible results from the filtration of organic and aqueous solutions in HPLC. Trace amount of samples containing impurities or contaminants can be easily removed, resulting in extending the lifetime of an HPLC analytical column. Usage Type Description and Ion-Chromato 4A 13A 25A 4A 13A 25A 13S 4P 13P 25P 4N 13N 4N 13N 4AI 13AI 25AI Composed of hydrophilic polyolefine membrane and polypropylene housing. Ideal for use in water and alcoholic solution targeted for sample preparation of protein analysis. This is a type that a chromatodisc and a syringe are combined. Composed of hydrophilic PTFE and polypropylene housing. Can be used without any pre-wet treatment for hydrophilics and hydrophobics. Acetonitrile 100% solution can be used. Solvents that can be used are alcohols, ethers, esters, ketones, hexanes. Autoclave sterilization is applicable. Composed of PTFE membrane and polypropylene housing. Excellent in solvent and chemical resistance. Therefore, it is ideal for use in organic solvents, strong acids, strong alkalis targeted for sample preparation of microanalysis. Autoclave sterilization is applicable. Composed of hydrophilic polyolefine membrane and polypropylene housing, which is treated by deionization. Ideal for use in sample preparation for ion chromatograph analysis. Type A Type P Type N

2 syringe filter for & samples Used for filtration of & samples Name 4P 13P 25P Fluorinated polymer membrane is used. & hydrophobic samples can be used without any pre-wetted treatment. Up to a 100% acetonitrile can be used. Ideal for filtration of alcohols, ethers, esters, ketones, and hexanes. polytetrafluoroethylene (PTFE) Size 4mm 13mm 25mm Size 8ψ x 18 18ψ x 22 29ψ x 24 Size 1mL 0.5 ~10mL 3~50mL M.A.O.P. 7kgf/cm2 5kgf/cm2 6kgf/cm2 Ethylene oxide gas / Autoclave Pore Size (μm) Cat. No syringe filter for samples Used for filtration of s Name 4A 13A 13S 25A Ideal for pretreatment of water and alcohol solution in HPLC and protein analysis.. membrane (Olefin polymer) Size 4mm 13mm 13mm 25mm Size 8ψ x 18 18ψ x 22 18ψ x 94 29ψ x 24 With a syringe Size 1mL 0.5 ~10mL 3~50mL Hold-UP Volume 10μL 30μL 30μL 100μL E.F.A. 0.07cm2 0.8cm2 0.8cm2 4.0cm2 M.A.O.P. 7kgf/cm2 5kgf/cm2 5kgf/cm2 6kgf/cm2 Ethelene oxide gas Pore Size (μm) Cat. No Pcs./Box

3 syringe filter for samples Used for filtration of s Name 4N 13N Superior chemical compatibility. Ideal for filtration of solvents, strong acids and alkali solution. Usable as a air-venting filter PTFE Size 4mm 13mm 25mm Size 8ψ x 18 18ψ x 22 29ψ x 24 Size 1mL 0.5 ~10mL 3~50mL M.A.O.P. 7 kgf/cm2 5 kgf/cm2 6 kgf/cm2 Ethylene oxide gas / Autoclave Pore Size (μm) Cat. No syringe filter for Ion-Chromatography samples Used for filtration of Ion chromatography s Name 4AI 13AI 25AI Deionized hydrophilic membrane is used. Ideal for filtration of ion chromatography samples Deionized membrane (Olefin polymer) Size 4mm 13mm 25mm Size 8ψ x 18 18ψ x 22 29ψ x 24 Size 1mL 0.5 ~10mL 3~50mL M.A.O.P. 7 kgf/cm2 5 kgf/cm2 6 kgf/cm2 Ethylene oxide gas Pore Size 0.45μm 0.45μm 0.45μm Cat. No

4 Chemical Resistance Information TYPE A : / Ion Chromatography O Enable TYPE P : / Enable but only for rapid use TYPE N : X Disable Chemical Name Chemical Description / Type A P N Acids Alkalis Alcohols Ethers Esters Glacial acetic acid Acetic acid 90% Acetic acid 30% O O Acetic acid 10% O O Hydrochloric acid Conc. X X X Hydrochloric acid 6N X O Sulfuric acid Conc. X X X Sulfuric acid 6N X O Nitric acid Conc. X X X Nitric acid 6N X O Ammonia 6N Ammonia 3N O O Potassium hydroxide 3N O O Sodium hydroxide 6N Sodium hydroxide 5N O O Sodium hydroxide 3N O O O Methanol O O O Ethanol O O O Propanol O O Isopropanol O O O Butanol O O O Amyl alcohol O O Ethylene glycol O O Propylene glycol O O Glycerin O O Ethyl ether O O O Isopropyl ether O O Dioxane X O O Tetrahydrofuran X O O Methyl acetate X O O Ethyl acetate X O O Isopropyl acetate X O Butyl acetate X O O

5 Ordering Information Usage Type Diameter (mm) Pore Size (um) Cat# QTY. 4A pcs pcs 13A pcs pcs 25A pcs pcs 13S pcs & 4P pcs 13P pcs pcs 25P pcs Ion-Chromato 4N 4 13N AI 4 13AI 13 25AI pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs GL Sciences, Inc. Japan 22-1 Nishishinjuku 6-Chome Shinjuku-ku, Tokyo, , Japan Phone: FAX: world@gls.co.jp GL Sciences, Inc. USA 4733 Torrance Blvd. Suite 255 Torrance, CA Phone: FAX: info@glsciencesinc.com International Distributors Visit our Website at

N6,6 Posidyne Membranes

N6,6 Posidyne Membranes Rev. Date: 20-Jun-2010 Ultipor Nylon 6,6 and N6,6 Posidyne Membrane Description Pall provides a complete range of Nylon 6,6 membranes for fluid filtration in the pharmaceutical, biotechnology, electronics,

More information

Chemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder

Chemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder Contact Us: www.pall.com/contact Chemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder Chemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder Introduction

More information

Micro Float-A-Lyzer READY-TO-USE MICRODIALYSIS DEVICES. Product Information & Operating Instructions

Micro Float-A-Lyzer READY-TO-USE MICRODIALYSIS DEVICES. Product Information & Operating Instructions Spectra/Por Micro Float-A-yzer EADY-TO-USE MICODIAYSIS DEVICES Product Information & Operating Instructions Table of Contents Introduction....................................1 Applications...................................2

More information

MEMBREX. Ready-to-use Syringe Filters < 1 up to 100 ml. Minimizes Loss of Sample. Minimale Holdup-Volume. Low Adsorption.

MEMBREX. Ready-to-use Syringe Filters < 1 up to 100 ml. Minimizes Loss of Sample. Minimale Holdup-Volume. Low Adsorption. MEMBREX < Ready-to-use Syringe Filters < 1 up to 100 ml Minimizes Loss of Sample Minimale Holdup-Volume Low Adsorption Optimized Shape MEMBREX Syringe filters Offering syringe filters in various shapes

More information

Tube O Reactor. (Micro: Cat. # K, K, K) (Medi: Cat. # K, K, K)

Tube O Reactor. (Micro: Cat. # K, K, K) (Medi: Cat. # K, K, K) 453PR G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name Tube O Reactor (Micro: Cat. # 786 024 4K, 786 024 8K, 786 024 15K) (Medi: Cat. # 786

More information

Spectra/Por. Float-A-Lyzer READY-TO-USE DIALYSIS DEVICES. Product Information & Operating Instructions

Spectra/Por. Float-A-Lyzer READY-TO-USE DIALYSIS DEVICES. Product Information & Operating Instructions Spectra/Por Float-A-yzer G2 EADY-TO-USE DIAYSIS DEVICES Product Information & Operating Instructions Table of Contents Introduction....................................1 Applications...................................2

More information

Chemical Polyurethane Polyethelyne PVC Nylon 11 Kynar

Chemical Polyurethane Polyethelyne PVC Nylon 11 Kynar ACETIC ACID, GLACIAL 4 2 4-1 ACETIC ACID, 30% 4 1 4 2 1 ACETONE 4 2 4 1 4 ACETYLENE 1 4 1 1 1 ALKAZENE 4 - - - - ALUMINUM CHLORIDE (aq) 3 2 1-1 ALUMINUM NITRATE (aq) 3-2 - 1 AMMONIA ANGYDROUS 4 2 1-4 AMMONIA

More information

Technical data and operating instructions. Vivaspin 4. Vivaspin 4 10K device for in vitro diagnostic use

Technical data and operating instructions. Vivaspin 4. Vivaspin 4 10K device for in vitro diagnostic use Technical data and operating instructions Vivaspin 4 Vivaspin 4 10K device for in vitro diagnostic use 85030-516-16 85030-516-16 Vivaspin 4 ml Introduction Storage conditions shelf life Vivaspin 4 ultrafiltration

More information

InertSustainSwift C8

InertSustainSwift C8 HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which

More information

Thermo Scientific Titan3 and Target2 Chromatography Syringe Filters. Performance filtration solutions. for sample preparation

Thermo Scientific Titan3 and Target2 Chromatography Syringe Filters. Performance filtration solutions. for sample preparation Thermo Scientific Titan3 and Target2 Chromatography Syringe Filters Performance filtration solutions for sample preparation syringe filters Sample preparation is a key stage in successful chromatography.

More information

This method describes the identification of the following prohibited colorants in cosmetic products:

This method describes the identification of the following prohibited colorants in cosmetic products: A. IDENTIFICATION BY TLC 1. SCOPE AND FIELD OF APPLICATION This method describes the identification of the following prohibited colorants in cosmetic products: Names C I number Pigment Orange 5 12075 Metanil

More information

Laboratory filtration. Principles and chemical compatibility chart

Laboratory filtration. Principles and chemical compatibility chart Laboratory filtration Principles and chemical compatibility chart Filtration simplified Basic filtration concepts and terms Selecting a filter with the appropriate properties can help you achieve accurate

More information

stance et Helper Eppendorf Pipet Helper Chemical Resistance

stance et Helper Eppendorf Pipet Helper Chemical Resistance stance et Helper Resistance N) Chemical Resistance Copyright 2017 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this publication may be reproduced without the prior

More information

The best material for original Eppendorf Tubes and Plates: Properties and chemical resistance of polypropylene

The best material for original Eppendorf Tubes and Plates: Properties and chemical resistance of polypropylene APPLICATION NOTE No. 056 I June 2013 The best material for original Eppendorf Tubes and Plates: Properties and chemical resistance of polypropylene Natascha Weiß, Susanne Pruszkowski, Eppendorf AG, Hamburg,

More information

Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for Sample Preparation

Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for Sample Preparation Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for ample Preparation -Instruction Manual- Table of Contents ection 1 Introduction...1 ection 2 Column Descriptions...2 ection 3 Instructions

More information

Chemical Compatibility of Filter Components

Chemical Compatibility of Filter Components Data Sheet Chemical Compatibility of Filter Components Compatibility of materials used in the construction of EMD Millipore products The tables on the following pages contain recommendations based solely

More information

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas Agilent Porous Polymer PLOT Columns: New Products, Expanded Uses, Prices Cut in Half! Product Brief Need improved resolution of small volatile compounds? Didn't try a PLOT column due to high price, short

More information

SOLUZIONI PER L ENERGIA TERMICA THERMAL ENERGY SOLUTIONS

SOLUZIONI PER L ENERGIA TERMICA THERMAL ENERGY SOLUTIONS Table on chemical resistance of rubber materials Class 1 little or no effect Class 2 minor effect Class 3 moderate effect Class 4 severe effect Chemical Conc. Temp. EPDM NBR VITON % C Acetic acid 10 50

More information

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography Introduction ASTM International publishes a number of different methods for the determination of volatile compounds in water-based coatings.

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

Glove Selection Chart

Glove Selection Chart Glove Selection Chart The following guide is a general guide for glove selection in relation to chemicals handled. The information presented here is believed to be accurate; however, we cannot guarantee

More information

Materials of Construction and Chemical Compatibility for Sensing and Control Products

Materials of Construction and Chemical Compatibility for Sensing and Control Products ADVANCED MATERIALS HANDLING TECHNICAL NOTE Materials of Construction and Compatibility for Sensing and Control Products INTRODUCTION Entegris Sensing and Control products are designed for use in highly

More information

8 Materials, Corrosion Resistance Tables

8 Materials, Corrosion Resistance Tables 8 Materials, Corrosion Resistance Tables Included among the criteria for meter selection are the materials to be utilized. Of primary interest are those materials which come in contact with the measuring

More information

Halar ECTFE chemical resistance chart

Halar ECTFE chemical resistance chart Technical Information Halar ECTFE chemical resistance chart Introduction Halar ECTFE is one of the most chemically resistant polymers available today. This chemical resistance is due to the chemically

More information

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products. Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products. CHRISTOPHER M. ENGLISH, CHRISTOPHER S. COX, FRANK

More information

Cellufine Butyl Cellufine Phenyl

Cellufine Butyl Cellufine Phenyl Hydrophobic Interaction Chromatography Media Cellufine Butyl Cellufine Phenyl Technical Data Sheet 2-1, Otemachi 2-Chome Chiyoda-ku, Tokyo 100-8105 JAPAN Phone +81-3-3243-6150 Fax +81-3-3243-6219 e-mail:

More information

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods How to Choose an SPE Product 1. Characterize the Sample Factors such as the analyte s polarity relative to the matrix, the presence of charged functional groups, solubility, molecular weight, etc., determine

More information

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC LC800 Smart HPLC Until now UHPLC From now Smart HPLC Smart HPLC Leads to Ultimate Performance Patent Pending S LC800 is a completely new and unique concept, designed for maximum performance in high resolution

More information

LATEST TECHNOLOGY IN Safe handling & Recovery OF Solvents in Pharma Industry

LATEST TECHNOLOGY IN Safe handling & Recovery OF Solvents in Pharma Industry LATEST TECHNOLOGY IN Safe handling & Recovery OF Solvents in Pharma Industry TYPICAL SOLVENT USE IN Pharma Industry Usage of solvents in an API process development is for: Diluent to carry out reaction

More information

Ferdowsi University of Mashhad

Ferdowsi University of Mashhad Spectroscopy in Inorganic Chemistry 2 Diatomic molecule C v and D h HCN H-H 3 contribution orbital electron Σ 0 σ 1 Π 1 π 1 Δ 2 δ 1 Φ 3 δ 1 Σ + Σ - 4 Linear molecule NO 2s+1 2 Π A 1 =Σ + 0 A 2 =Σ - 0 E

More information

Alcohols, Phenols and Ethers

Alcohols, Phenols and Ethers SUBJECTIVE PROBLEMS: Alcohols, Phenols and Ethers Q1. An organic liquid (A), containing C, H and O with boiling point: 78 o C, and possessing a rather pleasant odour, on heating with concentrated sulphuric

More information

Optical Isomer Separation Columns and Packing Materials

Optical Isomer Separation Columns and Packing Materials 02 Optical Isomer Separation s and Packing Materials CHIRAL ART----------------------------------- 26~29 YMC CHIRAL NEA (R), (S)-----------------------30 YMC CHIRAL CD BR------------------------------31

More information

An alcohol is a compound obtained by substituting a hydoxyl group ( OH) for an H atom on a carbon atom of a hydrocarbon group.

An alcohol is a compound obtained by substituting a hydoxyl group ( OH) for an H atom on a carbon atom of a hydrocarbon group. Derivatives of Hydrocarbons A functional group is a reactive portion of a molecule that undergoes predictable reactions. All other organic compounds can be considered as derivatives of hydrocarbons (i.e.,

More information

Spectroscopy in Inorganic Chemistry. Electronic Absorption Spectroscopy

Spectroscopy in Inorganic Chemistry. Electronic Absorption Spectroscopy Spectroscopy in Inorganic Chemistry Diatomic molecule C v and D h NO H-H 2 contribution orbital Σ 0 σ Π 1 π Δ 2 δ Φ 3 δ 3 Linear molecule NO 2s+1 2 Π A 1 =Σ + 0 A 2 =Σ - 0 E 1 =Π 1 E 2 =Δ 2 E 3 =Φ 3 4

More information

Aromatic Hydrocarbons

Aromatic Hydrocarbons Aromatic Hydrocarbons Aromatic hydrocarbons contain six-membered rings of carbon atoms with alternating single and double carbon-carbon bonds. The ring is sometimes shown with a circle in the center instead

More information

High Purity Chromasolv Solvents

High Purity Chromasolv Solvents Research Chemicals High Purity Chromasolv Solvents Part of Honeywell Research Chemical s Exclusive Riedel-de Haën Brand Portfolio The Chromasolv family of solvents are used in a variety of analytical applications

More information

Swell Sheet Chemical Resistance Guide

Swell Sheet Chemical Resistance Guide Swell Sheet Chemical Resistance Guide MULTI-SWELL 3760 Rev. 3/2018 LEAK-GARD 3750 KEY: A - Ideal for low pressure applications B - Fair, Depends on conditions; please contact Applications Engineering C

More information

TAMMSFLEX SL / TAMMSFLEX NS

TAMMSFLEX SL / TAMMSFLEX NS Acetic Acid, 10% 1 1 2 4 Acetic Acid, 50% 1 1 2 4 Acetic Acid, Glacial 1 4 - - Acetone 1 1 1 4 Acrylonitrile 2 4 - - Aluminum Sulfate(aq), 50% 1 1 1 1 Ammonium Chloride(aq), 50% 1 1 1 1 Ammonium Hydroxide(aq),

More information

PEROXIDE-FORMING CHEMICALS

PEROXIDE-FORMING CHEMICALS XVIII. PEROXIDE-FORMING CHEMICALS Some common laboratory chemicals can form peroxides on exposure to air. Peroxides are shocksensitive and can be violently explosive in concentrated form or as solids.

More information

Safe Installation and Use of the NanoRam Immersion Probe

Safe Installation and Use of the NanoRam Immersion Probe Safe Installation and Use of the NanoRam Immersion Probe Description: NanoRam Immersion Probe - 12 inch length; Immersion Probe Disposable Protective Sleeve Model Number: NR2-IMP; NR2-IMPS Part Number:

More information

PRODUCT DATA SHEET PDS A88_E

PRODUCT DATA SHEET PDS A88_E Plugs Suitable for A B C D Ref. Quantity Box/Bag (mm) (mm) (mm) (mm) TCP5 M12R + Pg7R M12R 4,5 8,5 10,8 4,5 3.000/100 TCP10 Pg9R Pg9R 6 12 12 4,5 2.000/100 TCP12 M12 + Pg7 M12 + Pg7 M16R + Pg11R M16R +

More information

CHEM 263 Oct 11, Lecture Outline 3: Alcohols, Ethers, Stereochemistry, Ketones, and Aldehydes. Ethanol

CHEM 263 Oct 11, Lecture Outline 3: Alcohols, Ethers, Stereochemistry, Ketones, and Aldehydes. Ethanol CEM 263 ct 11, 2016 Lecture utline 3: Alcohols, Ethers, Stereochemistry, Ketones, and Aldehydes Nomenclature of Alcohols Alcohols are compounds that have a hydroxyl group (-) bonded to a carbon atom (but

More information

Dionex IonPac AS28-Fast-4µm column

Dionex IonPac AS28-Fast-4µm column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS-Fast-4µm Columns Product Specifications The Thermo Scientific Dionex IonPac AS-Fast-4µm column is a high-capacity, hydroxide-selective anionexchange column

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page No.106 Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series Contents Page 1. Introduction 2. Features 3. Basic characteristics 3-1. Pore characteristics 3-2. Sample injection volume

More information

gerflor.com.au Stain chemicals

gerflor.com.au Stain chemicals gerflor.com.au Stain resistance: list of chemicals PRODUCTS/ TIME MIPOLAM TARALAY TARALAY / WALL CONCENTRATED ACID Acetic acid - CH 3 -COOH 14 0 0 0 0-1d 0-1d 0-1d 1d 1d 2d 0 0 0-1d Hydrochloric acid -

More information

Swell Sheet Chemical Resistance Guide

Swell Sheet Chemical Resistance Guide Swell Sheet Chemical Resistance Guide MULTI-SWELL 3760 Rev. 6/2016 LEAK-GARD 3750 KEY: A - Ideal for low pressure applications B - Fair, Depends on conditions; please contact Applications Engineering C

More information

CHEM 261 Dec 4, 2017

CHEM 261 Dec 4, 2017 200 CEM 261 Dec 4, 2017 REVIEW: 1. N 3 2 S 4 1. 2 Al 3 N 2 2. 2 Al 3 2. N 3 2 S 4 N 2 I II For the left hand reaction, I - to create a meta positioned, the first molecule to be subsituted should be N 2,

More information

Safe Operating Procedure

Safe Operating Procedure Safe Operating Procedure (Reviewed 1/09) USE AND STORAGE OF PEROXIDE-FORMING CHEMICALS (For assistance, please contact EHS at (402) 472-4925, or visit our web site at http://ehs.unl.edu/) Some common laboratory

More information

Multistep Synthesis of 5-isopropyl-1,3-cyclohexanedione

Multistep Synthesis of 5-isopropyl-1,3-cyclohexanedione Multistep Synthesis of 5-isopropyl-1,3-cyclohexanedione The purpose of this experiment was to synthesize 5-isopropyl-1,3-cyclohexanedione from commercially available compounds. To do this, acetone and

More information

Chemistry 110. Bettelheim, Brown, Campbell & Farrell. Ninth Edition

Chemistry 110. Bettelheim, Brown, Campbell & Farrell. Ninth Edition Chemistry 110 Bettelheim, Brown, Campbell & Farrell Ninth Edition Introduction to General, rganic and Biochemistry Chapter 14 Alcohols, Ethers and Thiols Alcohols have a ydroxyl Group, -, bonded to tetrahedral

More information

Chemical Storage According to Compatibility

Chemical Storage According to Compatibility Chemical Storage According to Compatibility To lessen risk of exposure to hazardous chemicals, all chemicals should be separated and stored according to hazard category and compatibility. *Storage Groups

More information

Eppendorf UVette. Instructions for use

Eppendorf UVette. Instructions for use Instructions for use Instructions Eppendorf see Fig. Tab. p. p. UVette for use Copyright 2014 Eppendorf AG, Hamburg, Germany. All rights reserved, including graphics and images. No part of this publication

More information

Alltech Alltima HP Introduction

Alltech Alltima HP Introduction Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life

More information

Hints for Strong Ion Exchange Resins

Hints for Strong Ion Exchange Resins Hints for Strong Ion Exchange Resins Chromatography Application Note AN98 Abstract Ion exchange columns are a powerful means of isolating and purifying compounds, but their use is limited due to lack of

More information

Peek Chemical Resistance

Peek Chemical Resistance Peek Chemical Resistance R = Resistant LR = Limited Resistance NR = Not Recommended ND = No Data Chemical Resistance 20 o C 60 o C 100 o C Acetaldehyde NR NR R Acetic acid (10%) R R R Acetic acid (glac./anh.)

More information

PRODUCT DATA SHEET PDS A112_E. Metric thread M 1.5 pitch CEI EN CEI EN 50262

PRODUCT DATA SHEET PDS A112_E. Metric thread M 1.5 pitch CEI EN CEI EN 50262 reduced cable entry Metric thread M 1.5 pitch CEI EN 60423 CEI EN 50262 Ref. P Fixing A B C L Light Hole min-max Spanner min-max Quantity Grey (mm) (mm) (mm) (mm) (mm) 1910S.M16N M16x1,5 16,5 4-7,5 19

More information

Lesmahagow High School

Lesmahagow High School Lesmahagow High School Chemistry Advanced Higher Unit 1 Physical Chemistry TUTORIAL EXERCISES 1. Consider the equilibrium below: Unit 1 Physical Chemistry Tutorial 1.1 The Equilibrium Constant The equilibrium

More information

Egualen Sodium Granules

Egualen Sodium Granules Egualen Sodium Granules Dissolution Weigh accurately an amount of Egualen Sodium Granules, equivalent to about 5 mg of egualen sodium (C 15 H 17 NaO 3 S 1/3 H2O) according to the labeled amount,

More information

Amicon Ultra-15 10K Centrifugal Filter Devices

Amicon Ultra-15 10K Centrifugal Filter Devices User Guide Amicon Ultra-15 10K Centrifugal Filter Devices for volumes up to 15 ml UFC901008 UFC901024 UFC901096 C V English Introduction Amicon Ultra-15 10K centrifugal filter devices provide fast ultrafiltration,

More information

Headspace Technology for GC and GC/MS: Features, benefits & applications

Headspace Technology for GC and GC/MS: Features, benefits & applications Headspace Technology for GC and GC/MS: Features, benefits & applications Karima Baudin Oct 2015 Why use Headspace? Very Simple no to minimum sample prep Robust enhance uptime Non-detectable carry-over

More information

A freely accessible HNS data base

A freely accessible HNS data base Improving Member States preparedness to face an HNS pollution of the Marine System (HNS-MS) A freely accessible HNS data base The HNS data base in a nutshell 120 HNS, described by 90+ data covering 6 main

More information

Dispensette S NEW! Bottle-top Dispenser. The New Generation! n New discharge tube. n New valve system. n Faster priming. n Less force needed during

Dispensette S NEW! Bottle-top Dispenser. The New Generation! n New discharge tube. n New valve system. n Faster priming. n Less force needed during The New Generation! Dispensette S Bottle-top Dispenser F I R S T C L A S S B R A N D Innovative ideas with trusted technology the new bottle-top dispenser. n New discharge tube with or without recirculation

More information

Appendix 5: table of chemical compatibility for tubing

Appendix 5: table of chemical compatibility for tubing Appendix 5: table of chemical compatibility for tubing KEY 1 Excellent 2 Good 3 Fair 4 Not recommended - no data Silicone PharMed Iso-Versinic PVC Acetaldehyde 3 4 4 2 Acetamide, 67% in w 1 2 4 4 Acetate

More information

PREVENTING HAZARDOUS WASTE FINES

PREVENTING HAZARDOUS WASTE FINES University of Medicine and Dentistry of New Jersey EOHSS FACTSHEET PREVENTING HAZARDOUS WASTE FINES In the last few years institutions such as MIT, University of New Hampshire, Yale, Stanford, and Boston

More information

BELZONA PRODUCT DATA G504 CHEMICAL RESISTANCE OF BELZONA 5892

BELZONA PRODUCT DATA G504 CHEMICAL RESISTANCE OF BELZONA 5892 Alcohols, Aldehydes and Ketones Organic Acids Inorganic Acids BELZONA RODUCT DATA 504 CHEICAL RESISTANCE OF BELZONA 5892 10% * - Hydrochloric acid HCl 5% * - (647-01-0) 1% * - hosphoric acid (orthophosphoric

More information

Sizes 48" x 96" (1.22m x 2.44m) Custom sheet sizes available upon request

Sizes 48 x 96 (1.22m x 2.44m) Custom sheet sizes available upon request Applications Decorative paneling Partitions Water features Signage Furniture Displays and more... Attributes Excellent UV properties High impact resistance - 17x greater than glass and 4x greater than

More information

Dispensette S NEW! Bottle-top Dispenser. The New Generation! n New discharge tube. n New valve system. n Faster priming. n Less force needed during

Dispensette S NEW! Bottle-top Dispenser. The New Generation! n New discharge tube. n New valve system. n Faster priming. n Less force needed during The New Generation! Dispensette S Bottle-top Dispenser F I R S T C L A S S B R A N D Innovative ideas with trusted technology the new bottle-top dispenser. n New discharge tube with or without recirculation

More information

Optimizing GPC Separations

Optimizing GPC Separations Optimizing GPC Separations Criteria for Solvent Selection True sample solubility (Polarity and Time dependant) Compatibility with columns Avoid non-size exclusion effects (eg adsorption by reverse phase

More information

ProPac WCX-10 Columns

ProPac WCX-10 Columns ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

Enzymatic Assay of CARBOXYPEPTIDASE P (EC )

Enzymatic Assay of CARBOXYPEPTIDASE P (EC ) PRINCIPLE: N-CBZ-Glu-Tyrosine + H2O Carboxypeptidase P > N-CBZ-L-Glutamic Acid + L-Tyrosine Abbreviation used: N-CBZ = N-Carbobenzoxy CONDITIONS: T = 30 C, ph = 3.7, A 570nm, Light path = 1 cm METHOD:

More information

How proteins separate on reverse-phase HPLC

How proteins separate on reverse-phase HPLC 1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP

More information

3.0 Spiraltek Rolled Filters

3.0 Spiraltek Rolled Filters 3.0 Spiraltek Rolled Filters s of Construction Polypropylene Filter Core and Support Polypropylene Media (16.5 ft 2 ) Fiberglass Reinforced Polypropylene Encapsulation Valves of Polypropylene Valve Springs

More information

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

Mass Spectral Studies of Polypropylene Chromatographic Well Plates Mass Spectral Studies of Polypropylene Chromatographic Well Plates Brian King, Thermo Fisher Scientific, Runcorn, Cheshire, UK Detlev Lennartz, Thermo Fisher Scientific, Langerwehe, Germany White Paper

More information

2017 Reaction of cinnamic acid chloride with ammonia to cinnamic acid amide

2017 Reaction of cinnamic acid chloride with ammonia to cinnamic acid amide 217 Reaction of cinnamic acid chloride with ammonia to cinnamic acid amide O O Cl NH 3 NH 2 C 9 H 7 ClO (166.6) (17.) C 9 H 9 NO (147.2) Classification Reaction types and substance classes reaction of

More information

groups I and II cations, amines, divalent transition metals

groups I and II cations, amines, divalent transition metals IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,

More information

CHEMICAL RESISTANCE OF BELZONA 1523 FN10150

CHEMICAL RESISTANCE OF BELZONA 1523 FN10150 Organic Acids Inorganic Acids CHEICAL RESISTANCE OF BELZONA 1523 20% - Hydrochloric acid HCl 10% - 5% - (647-01-0) 3% - Nitric acid HNO 3 (7697-37-2) 10% - Nitrous acid HNO 2 (7782-77-6) 10% - hosphoric

More information

Safety Manual > Incompatible Chemicals Partial Listing

Safety Manual > Incompatible Chemicals Partial Listing Safety Manual > Incompatible Chemicals Partial Listing C. Incompatible Chemicals Partial Listing Chemical Incompatible Chemicals Acetic acid Chromic acid, nitric acid, permanganates, and peroxides Acetic

More information

Desalting and Buffer Exchange with Corning Spin-X UFCentrifugal Concentrators

Desalting and Buffer Exchange with Corning Spin-X UFCentrifugal Concentrators Desalting and Buffer Exchange with Corning Spin-X UFCentrifugal Concentrators Protocol Table 1. Maximum Recommended Maximum Volume and (Centrifugal Force) for Spin-X UF Concentrators Concentrator Spin-X

More information

ALCOHOLS AND PHENOLS

ALCOHOLS AND PHENOLS Chem 306 Name Partner Section (Circle) M Tu W Th Date ALCOHOLS AND PHENOLS Purpose: In this laboratory activity you will investigate some chemical and physical properties of alcohols and phenols Introduction:

More information

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE Translated English of Chinese Standard: GB5009.28-2016 www.chinesestandard.net Buy True-PDF Auto-delivery. Sales@ChineseStandard.net NATIONAL STANDARD OF THE GB PEOPLE S REPUBLIC OF CHINA GB 5009.28-2016

More information

Gloves: choice and use

Gloves: choice and use Gloves: choice and use Adopted April 15 th, 2003 Comité sectoriel de sécurité du Département de chimie Université Laval Wearing gloves: why? Gloves are worn for protection. However, gloves do not always

More information

500 SERIES CHEMICAL RESISTANCE GUIDE

500 SERIES CHEMICAL RESISTANCE GUIDE 500 SERIES CHEMICAL RESISTANCE GUIDE INTRODUCTION The Stonchem 500 Series Chemical Resistance Guide is designed to aid in the proper selection of material for every job application. Exposure to over 250

More information

Preparation, analysis of samples in HPLC

Preparation, analysis of samples in HPLC Preparation, analysis of samples in HPLC Preparation, analysis of samples in HPLC Leader on the market of solvents for chromatography and trace analysis, Carlo Erba Réactifs-SdS extended its range of solvents

More information

TEPZZ 6ZA_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: C07D 401/06 ( )

TEPZZ 6ZA_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: C07D 401/06 ( ) (19) TEPZZ 6ZA_T (11) EP 3 112 360 A1 (12) EUROPEAN PATENT APPLICATION (43) Date of publication: 04.01.17 Bulletin 17/01 (1) Int Cl.: C07D 1/06 (06.01) (21) Application number: 1617780.2 (22) Date of filing:

More information

1. Name the following compound. Use the IUPAC system and include the stereochemical designations.

1. Name the following compound. Use the IUPAC system and include the stereochemical designations. Chemistry 51 Exam 1, Summer 2004 This is a closed book exam. The exam lasts 100 minutes. All answers must appear on the answer sheet. Only the answer sheet will be collected. Put your name on the answer

More information

Ondansetron Hydrochloride Tablets

Ondansetron Hydrochloride Tablets Ondansetron Hydrochloride Tablets Dissolution Perform the test with 1 tablet of Ondansetron Hydrochloride Tablets at 50 revolutions per minute according to the Paddle method, using 900 ml of water

More information

Background on Solubility

Background on Solubility CHEM254 01 Open Notebook Science Solubility Challenge 1 For the first laboratory exercise of this semester we are going to participate in the Open Notebook Science (ONS) solubility challenge http://onschallenge.wikispaces.com/.

More information

Chemical Compatibility Guide Issue One

Chemical Compatibility Guide Issue One CNAF X Chemical Compatibility Guide Issue One Chemical Compatibility Guide Chieftain X, Centurion X, and Sentinel X compressed non asbestos fibre sheet gasket materials The following information is issued

More information

CHEMICAL RESISTANCE DATA FOR POLYETHYLENES

CHEMICAL RESISTANCE DATA FOR POLYETHYLENES CHEMICAL RESISTANCE DATA FOR POLYETHYLENES [ R = Resistant LR= Low Resistance NR= Not Resistant] 23 o C 60 o C 23 o C 60 o C Acetaldehyde(100%) LR NR LR NR Acetic acid (10%) R R R R Acetic acid (50%) R

More information

Supporting Information

Supporting Information Supporting Information Wiley-VCH 2007 69451 Weinheim, Germany 1 Dihydrogen Reduction of Carboxylic Esters to Alcohols Catalyzed by Homogeneous Ruthenium Complexes: High Efficiency and Unprecedented Chemoselectivity.

More information

MEDROXYPROGESTERONE INJECTION

MEDROXYPROGESTERONE INJECTION September 2011 RESTRICTED DRAFT PROPOSAL FOR The International Pharmacopoeia MEDROXYPROGESTERONE INJECTION (September 2011) DRAFT FOR COMMENT Should you have any comments on the attached draft proposal,

More information

Partial Periodic Table

Partial Periodic Table CEM 3311, Fall 2011 Professor Walba Third our Exam November 17, 2011 scores: 1) 20 2) 20 3) 20 4) 20 5) 20 100 CU onor Code Pledge: n my honor, as a University of Colorado at Boulder tudent, I have neither

More information

FUNDERMAX GMBH TEST REPORT

FUNDERMAX GMBH TEST REPORT FUNDERMAX GMBH TEST REPORT SCOPE OF WORK SEFA 3 2010, 2.1 Analysis of Max Compact Interior Plus White and Black Plaques REPORT NUMBER 103600635GRR 001a ISSUE DATE 25 September 2018 PAGES 22 DOCUMENT CONTROL

More information

HPLC Sample Preparation

HPLC Sample Preparation HPLC Sample Preparation Rely on Sartorius solutions and benefit from optimized workflows for clean results mau 400 350 300 250 200 150 100 50 0 50 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0

More information

HAZARDOUS MATERIALS SURVEY. Note: List ALL virgin stock materials in current and projected inventories LAB NAME: PI: ADDRESS:

HAZARDOUS MATERIALS SURVEY. Note: List ALL virgin stock materials in current and projected inventories LAB NAME: PI: ADDRESS: HAZARDOUS MATERIALS SURVEY Note: List ALL virgin stock materials in current and projected inventories LAB NAME: PI: ADDRESS: Please read each definition of the following Hazardous Materials carefully and

More information

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench Application Note Forensic Toxicology and Drug Testing Author Jared Bushey Agilent Technologies, Inc. 285 Centerville

More information