MetWorks Metabolite Identification Software

Size: px
Start display at page:

Download "MetWorks Metabolite Identification Software"

Transcription

1 m a s s s p e c t r o m e t r y MetWorks Metabolite Identification Software Enabling Confident Analysis of Metabolism Data Part of Thermo Fisher Scientific

2 MetWorks Software for the Confident Analysis of Metabolism Data MetWorks with Mass Frontier software provides a simple and complete solution for identifying drug metabolites. MetWorks software automates and simplifies identification of Phase I and Phase II metabolites Automatically identify and generate ion chromatograms for all expected metabolites. Detect and identify unpredicted modifications with advanced data analysis tools: Further confirm potential metabolites using background subtraction based on UV or radiochromatogram data. Analyze sample and controls and utilize MS n spectra, retention time, and m/z to target putative metabolites Refine metabolite identification using Mass Defect Filtering of high mass accuracy data 2MetWorks Metabolite Identification Software Incorporate isotope pattern recognition of both natural and artificial isotopes Correlate MS/MS and MS 3 spectra with those from the parent drug to identify common product ions and mass shifts related to neutral losses

3 MetWorks Simplifies Data Visualization and Reporting MetWorks data analysis complements the Data Dependent and Dynamic Exclusion capabilities of all Thermo Scientific ion trap mass spectrometers for simultaneous determination of metabolic stability and structural identification. MetWorks provides capabilities for confident analysis of metabolism data Detecting Known Modifications Detecting Unpredicted Modifications Multiple Mass Defect Filter Automatic Isotope Pattern Recognition Spectral Correlation Tools for Metabolite Confirmation Confident Metabolite Identification Comprehensive Data Visualization and Reporting MetWorks software is compatible with all Thermo Scientific mass spectrometers capable of performing MS/MS and MS n fragmentation. In addition, MetWorks allows high resolution accurate mass data from the LTQ Orbitrap and LTQ FT instruments to be fully leveraged. 3

4 Detecting Known Modifications Automatic Identification of Expected Modifications Choose from an extensive list of Phase I and II modifications and create a custom list of single and combined expected modifications for the parent drug of interest. During data Convenient reporting software displays full scan and product ion mass spectra for each expected metabolite in order to verify predicted biotransformations. acquisition, the user has the option to specify a custom MS/MS list to target metabolites. During data processing, MetWorks software will automatically generate Extracted Ion Chromatograms (EIC) for each expected metabolite. 4MetWorks Metabolite Identification Software Expected Modifications View A custom list of expected modifications was used for the analysis of Loperamide data from the Thermo Scientific LTQ XL linear ion trap. Extracted ion chromatograms for unmetabolized Loperamide (m/z ) and its demethylated (m/z ) and hydroxylated (m/z ) metabolites are shown at the top of the figure above. The full scan mass spectra (left) and product ion spectra (MS/MS, right) for demethylated Loperamide are shown at the bottom of the figure.

5 Detecting Unpredicted Modifications Simplify Identification of Unknown Drug Metabolites MetWorks software provides the flexibility to filter data in order to identify low and high abundance peaks related to the parent drug. These masses may arise from metabolites which were not initially predicted or included in a targeted mass list. MetWorks provides a number of different software filters to help detect these components so that automated MS n fragmentation can be triggered and structural identification confirmed. Component Subtraction Using Controls Component subtraction can remove the effect of matrix or non-drug related interferences from the sample data and uncover unpredicted metabolites. A MetWorks algorithm compares components found in Sample and Control using composite MS n data in addition to full scan retention time (RT) and m/z values. Component Detection View Highlighting the components at RT 4.4 minutes in Sample (metabolized Loperamide) and Control (unmetabolized Loperamide) total ion chromatograms (top two panels) links the components to their composite MS n spectra (bottom panel). Since the RT (4.4 minutes), m/z (437.30) and product ion spectra (MS/MS) of these two components are identical in both Sample and Control, they were automatically labeled in red in the chromatograms and can be excluded from further analysis. Components unique to the sample are labeled in green and are shown in the panel labeled Potential Modifications. Data was obtained using the LTQ XL linear ion trap. Using these criteria, Components in the Sample and Control that are the same can automatically be excluded from further analysis, while components that are unique to the sample are automatically highlighted in green for easy visualization. These components are potential drug metabolites. If a Control data file is not available, another option is to perform the background subtraction using the solvent (not shown). 5

6 Multiple Mass Defect Filter Biotransformations cause predictable changes to the mass of the parent drug. Mass defects arise since molecular masses of metabolites are non-integer and deviate from nominal mass values. This results in small changes of the mass defect between the parent drug and its metabolites. The MetWorks Mass Defect removes a significant amount of background interference originating from the matrix and unmasks low abundance metabolite peaks. MetWorks software enables the use of a combination of up to six Mass Defect Filters, such that all the results are compiled into one chromatogram. 6MetWorks Metabolite Identification Software Filter takes advantage of the high mass accuracy data from the LTQ Orbitrap and LTQ FT Ultra and the known mass defects for different biotransformations. After data acquisition, a software filter removes ions with mass defects that are outside a userdefined mass defect window based on all possible modifications of the parent drug. Consequently, this process automatically The effect of using single and multiple Mass Defect Filters on visualizing Oxime metabolites in rat hepatocytes. Unfiltered, single Phase I, single Phase II and combined Phase I and Phase II filtered base peak chromatograms are shown. The parent drug Oxime is highlighted. Data was obtained using the LTQ Orbitrap hybrid mass spectrometer. Note: the y-axis intensity value is lower for Phase II MDF than the other chromatograms shown.

7 Automatic Isotope Pattern Recognition Drug candidates which contain elements such as bromine and chlorine have easily distinguishable isotope patterns which are not common in endogenous metabolites found in body fluids. Drugs can also be artificially labeled using stable isotopes including 13 C, 2 H, and 15 N. For metabolism studies, these unique isotope patterns can act as intrinsic or extrinsic signatures that can be used to efficiently detect drug metabolites. MetWorks software can filter full scan mass spectra based on the changes in mass and relative abundance of these isotopes and automatically display extracted ion chromatograms representing these isotope patterns that indicate potential metabolites. The top panel shows the EIC for an unexpected demethylated hydroxylated Loperamide metabolite at m/z identified by isotope pattern recognition, which includes a rearrangement and a modification. The bottom panel shows full scan MS of the metabolite indicating a distinct chlorine isotope pattern with a mass difference of two (highlighted in red) that was automatically recognized by MetWorks software and determined to be desmethyl-hydroxyl Loperamide. Data was obtained using the LTQ Orbitrap hybrid mass spectrometer. 7

8 MetWorks Metabolite Identification Software Spectral Correlation Spectral correlation analysis compares MS/MS or MS 3 spectra between the sample (metabolized drug) and a reference (typically parent drug). The MetWorks correlation algorithm searches for product ion spectral components that are the same in metabolized and unmetabolized drugs (common product ions) or different through a consistent mass shift that indicates a chemical modification such as an adduct. The related parent ions are automatically highlighted as metabolites of interest. Spectral Correlations View Chromatogram before (A) and after (B) spectral correlation indicates identification of an unpredicted dehydroxy rearrangement of Loperamide at RT of 4.04 minutes with m/z of The MS 3 spectra of (C) unmetabolized Loperamide (reference) and (D) the rearranged dehydroxy metabolite are shown with common product ions highlighted in blue. Data was obtained using the LTQ XL linear ion trap. 8

9 Tools for Metabolite Confirmation Component Subtraction Using UV and Radiometric Data UV spectra and radiographic analysis can generate information that is complementary to mass spectrometry data and may help confirm the peaks that are related to the parent drug. These traces can be displayed together with the total ion chromatogram for visual comparison. In addition, the information from one trace can be used to confirm components that are related to the parent drug. Components that are the same in Sample (metabolized Loperamide) and Control (unmetabolized Loperamide) and that have retention times that do not match peaks in the UV chromatogram are removed from the total ion chromatogram (Components remaining after control and UV subtraction). The remaining peaks are likely drug metabolites. 9

10 MetWorks Metabolite Identification Software Confident Metabolite Identification Once putative metabolites are identified, the location of the functional modification and the assignment of overall structure can be facilitated using Mass Frontier software. Chemical Structures representing the possible sites of modification can be created and fragmented in silico using general mechanistic fragmentation rules and the extensive Fragmentation Library that contains literature-based fragmentation schemes. The fragment ions generated using this approach can be directly compared to those acquired during LC-MS n analysis. Mass spectral peaks can be automatically annotated with their corresponding structures. Structural annotation of N-demethylated metabolite of Loperamide is shown. Once metabolite structure is confirmed using Mass Frontier s fragmentation schemes, product ion structures can be assigned to the mass spectral peaks. 10

11 Comprehensive Data Visualization and Reporting The MetWorks Report View can be customized to display the information about the parent drug and the set of identified metabolites. This may include elemental formula, type of modification, structure, retention time, m/z, associated chromatograms, a list of the most intense fragment ions, spectral tree (MS n information), and mass difference between parent and metabolite. The Report View can be used to create reports in Adobe PDF, Microsoft Word, and Microsoft Excel formats. MetWorks Report View The user can add structures for characterized components and save them with the results file. F1-F3 are the most abundant fragment or product ions from the MS n data. Delta denotes the difference between the masses of the parent and metabolized drug. 11

12 Laboratory Solutions Backed by Worldwide Service and Support Tap our expertise throughout the life of your instrument. Thermo Scientific Services extends its support throughout our worldwide network of highly trained and certified engineers who are experts in laboratory technologies and applications. Put our team of experts to work for you in a range of disciplines from system installation, training and technical support, to complete asset management and regulatory compliance consulting. Improve your productivity and lower the cost of instrument ownership through our product support services. Maximize uptime while eliminating the uncontrollable cost of unplanned maintenance and repairs. When it s time to enhance your system, we also offer certified parts and a range of accessories and consumables suited to your application. To learn more about our products and comprehensive service offerings, visit us at In addition to these offices, Thermo Fisher Scientific maintains a network of representative organizations throughout the world. Australia analyze.au@thermo.com Austria analyze.at@thermo.com Belgium analyze.be@thermo.com Canada analyze.ca@thermo.com China analyze.cn@thermo.com Denmark analyze.dk@thermo.com France analyze.fr@thermo.com Germany analyze.de@thermo.com India analyze.in@thermo.com Italy analyze.it@thermo.com Japan analyze.jp@thermo.com Latin America analyze.la@thermo.com Netherlands analyze.nl@thermo.com South Africa analyze.sa@thermo.com Spain analyze.es@thermo.com Sweden / Norway / Finland analyze.se@thermo.com Switzerland analyze.ch@thermo.com UK analyze.uk@thermo.com USA analyze.us@thermo.com Thermo Fisher Scientific, San Jose, CA USA is ISO Certified Thermo Fisher Scientific Inc. All rights reserved. Mass Frontier and Fragmentation Library are trademarks of HighChem, Ltd; Adobe is a registered trademark of Adobe Systems Incorporated; Microsoft is a registered trademark of Microsoft Corporation. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. BR62428_E 10/07S

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer m a s s s p e c t r o m e t r y Finnigan TC/EA High Temperature Conversion Elemental Analyzer Analyze Detect Measure Control Finnigan TC/EA High Temperature Conversion Elemental Analyzer Finnigan TC/EA

More information

LTQ XL Linear Ion Trap Mass Spectrometer More Structural Information with MS n

LTQ XL Linear Ion Trap Mass Spectrometer More Structural Information with MS n m a s s s p e c t r o m e t r y LTQ XL Linear Ion Trap Mass Spectrometer More Structural Information with MS n Part of Thermo Fisher Scientific SUPERIR I TRAP TECHLGY From the leader in Ion Trap Mass Spectrometry,

More information

Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap

Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap m a s s s p e c t r o m e t r y Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap World's fastest and most sensitive ion trap mass spectrometer Part of Thermo Fisher Scientific Thermo Scientific

More information

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer m a s s s p e c t r o m e t r y Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer Reset Your Expectations Part of Thermo Fisher Scientific Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer

More information

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery Metabolite Stability Screening and Hotspot Metabolite Identification by Combining High-Resolution, Accurate-Mass Nonselective and Selective Fragmentation Tim Stratton, Caroline Ding, Yingying Huang, Dan

More information

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS m a s s s p e c t r o m e t r y Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS Fully Automated Multi-Element Isotope Analysis for C, N, S, O, H Food Testing Forensics Environmental Analysis

More information

LCQ Fleet Ion Trap LC/MS n Exceptional Analytical Value

LCQ Fleet Ion Trap LC/MS n Exceptional Analytical Value m a s s s p e c t r o m e t r y LCQ Fleet Ion Trap LC/MS n Exceptional Analytical Value Part of Thermo Fisher Scientific LCQ Fleet Ion Trap LC/MS n Unbeatable Rapid and Reliable Detection for Every Lab

More information

Thermo Scientific LC IsoLink

Thermo Scientific LC IsoLink m a s s s p e c t r o m e t r y Thermo Scientific LC IsoLink The Link from HPLC to Isotope Ratio Mass Spectrometry Carbohydrates Amino Acids, Nucleotides Organic Acids Pharmaceuticals Part of Thermo Fisher

More information

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis Tim Stratton 1, Yingying Huang 1, Katianna Pihakari 1, Ian Acworth 2, and Michael Weber 2 1 Thermo Fisher Scientific,

More information

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Olaf Scheibner and Maciej Bromirski Thermo Fisher Scientific, Bremen, Germany Overview Purpose: Improve the performance

More information

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry O. Scheibner, 1 P. van Baar, 2 F. Wode, 2 U. Dünnbier, 2 K. Akervik, 3 J. Humphries, 3 M. Bromirski 1

More information

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer Application ote: 54 Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap rbitrap Hybrid Mass Spectrometer Kate Comstock, Yingying Huang; Thermo Fisher Scientific,

More information

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM Application Note: 320 Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM Key Words Metabolism Study Structure Elucidation Metabolite ID Mass Frontier Chromatography

More information

High-Field Orbitrap Creating new possibilities

High-Field Orbitrap Creating new possibilities Thermo Scientific Orbitrap Elite Hybrid Mass Spectrometer High-Field Orbitrap Creating new possibilities Ultrahigh resolution Faster scanning Higher sensitivity Complementary fragmentation The highest

More information

Finnigan TSQ Quantum Discovery MAX

Finnigan TSQ Quantum Discovery MAX m a s s s p e c t r o m e t r y Finnigan TSQ Quantum Discovery MAX Round-the-clock productivity Analyze Detect Measure Control Lit Finnigan Sheet TSQ White Quantum Head Discovery MAX Extraordinary Value

More information

Thermo Scientific TRITON Thermal Ionization MS. Thermo Scientific NEPTUNE Multicollector ICP-MS. High Resolution Multicollector Mass Spectrometers

Thermo Scientific TRITON Thermal Ionization MS. Thermo Scientific NEPTUNE Multicollector ICP-MS. High Resolution Multicollector Mass Spectrometers m a s s s p e c t r o m e t r y Thermo Scientific TRITON Thermal Ionization MS Thermo Scientific NEPTUNE Multicollector ICP-MS High Resolution Multicollector Mass Spectrometers Part of Thermo Fisher Scientific

More information

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput Yi Zhang 1, Zhiqi Hao 1, Markus Kellmann 2 and Andreas FR. Huhmer

More information

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis Thermo Scientific Pesticide Explorer Collection Start-to-finish workflows for pesticide analysis Comprehensive Pesticide Analysis Solutions Pesticide Explorer Collection Selection table Lab Profile Routine

More information

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry Olaf Scheibner, 1 Patrizia van Baar, 2 Florian Wode, 2 Uwe Dünnbier, 2 Kristi Akervik, 3 Jamie Humphrie,

More information

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3 Second-Generation Electron Transfer Dissociation (ETD) on the Thermo Scientific Orbitrap Fusion Mass Spectrometer with Improved Functionality, Increased Speed, Christopher Mullen, 1 Lee Earley, 1 Jean-Jacques

More information

for XPS surface analysis

for XPS surface analysis Thermo Scientific Avantage XPS Software Powerful instrument operation and data processing for XPS surface analysis Avantage Software Atomic Concentration (%) 100 The premier software for surface analysis

More information

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS Daniel Kutscher, 1 Jörg Bettmer, 2 Torsten Lindemann, 1 Shona McSheehy-Ducos, 1 Lothar Rottmann 1 1 Thermo Fisher Scientific, Germany 2

More information

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION A purpose-built collection of the best-inclass components for forensic toxicology Whether you re challenged to present reliable and secure forensic sample

More information

Thermo Scientific TPDRO 1100 Advanced Catalyst Characterization

Thermo Scientific TPDRO 1100 Advanced Catalyst Characterization s u r f a c e a n a l y s i s Thermo Scientific TPDRO 11 Advanced Catalyst Characterization For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption Metal supported catalysts Oil industry

More information

TPDRO 1100 Advanced Catalyst Characterization. For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption

TPDRO 1100 Advanced Catalyst Characterization. For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption s u r f a c e a n a l y s i s TPDRO 11 Advanced Catalyst Characterization For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption Analyze Detect Measure Control TPDRO 11 Advanced

More information

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy molecular spectroscopy Introduction to Fourier Transform Infrared Spectroscopy Part of Thermo Fisher Scientific Introduction What is FT-IR? FT-IR stands for Fourier Transform InfraRed, the preferred method

More information

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer Reiko Kiyonami, Mary Blackburn, Andreas FR Hühme: Thermo Fisher

More information

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap Dirk Nolting and Andreas Wieghaus Thermo Fisher Scientific, Bremen, Germany Overview Purpose: Characterize the rate

More information

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS Thermo Scientific ConFlo IV Universal Interface Continuous Flow Interface Isotope Ratio MS 3 ConFlo IV Universal Interface for Continuous Flow Isotope Ratio MS The development of Continuous Flow carrier

More information

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy Introduction to Fourier Transform Infrared Spectroscopy Introduction What is FTIR? FTIR stands for Fourier transform infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR

More information

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS Jason Lai, Jia Wang, Brad Hart, Pavel Aronov, Kristine Van Natta, Marta Kozak, Jorge Valdivia, Andy Jacobs, Haibo

More information

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites Robert Heintz, Mark Wall, Jennifer Ramirez, Stephan Woods Thermo Fisher Scientific, Madison WI Overview Purpose:

More information

Fast, Effective XPS Point Analysis of Metal Components

Fast, Effective XPS Point Analysis of Metal Components Application Note: 52297 Fast, Effective XPS Point Analysis of Metal Components Chris Baily and Tim Nunney, Thermo Fisher Scientific, East Grinstead, West Sussex, UK Key Words K-Alpha Auto-Analysis Multi-Spectrum

More information

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use Shih-Tse Jason Lai, Jia Wang, Brad Hart, Kristine Van Natta, Marta Kozak, Jorge Valdivia, Haibo Wang,

More information

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer Defining quality standards for the analysis of solid samples Redefine your quality standards for the elemental analysis of solid samples

More information

Thermo Scientific irm-gc/ms Technology

Thermo Scientific irm-gc/ms Technology m a s s s p e c t r o m e t r y Thermo Scientific irm-gc/ms Technology Get More Information from Your GC Samples Environmental Studies Forensics and Doping Control Ecology and Metabolic Studies Geochemistry

More information

Finnigan TRITON Finnigan NEPTUNE. High Resolution Multicollector Mass Spectrometers

Finnigan TRITON Finnigan NEPTUNE. High Resolution Multicollector Mass Spectrometers m a s s s p e c t r o m e t r y Finnigan TRITON Finnigan NEPTUNE High Resolution Multicollector Mass Spectrometers Analyze Detect Measure Control Finnigan TRITON / Finnigan NEPTUNE High Resolution Multicollector

More information

Thermo Scientific DELTA V Advantage DELTA V Plus

Thermo Scientific DELTA V Advantage DELTA V Plus m a s s s p e c t r o m e t r y Thermo Scientific DELTA V Advantage DELTA V Plus The Next Generation Isotope Ratio MS Part of Thermo Fisher Scientific Thermo Scientific DELTA V Advantage DELTA V Plus Thermo

More information

Finnigan TRACE DSQ GC/MS

Finnigan TRACE DSQ GC/MS m a s s s p e c t r o m e t r y Finnigan TRACE DSQ GC/MS Discover Unmatched Sensitivity, Performance and Value Full-scan sensitivity for the demanding environmental analysis Proven performance for difficult

More information

of mass spectrometry

of mass spectrometry Thermo Scientific 253 Ultra High resolution isotope ratio MS Discover a new world of mass spectrometry Paleoclimatology Atmospheric science Biogeochemistry Petrology Discover the isotopic anatomy of molecules

More information

DFS Magnetic Sector GC/MS

DFS Magnetic Sector GC/MS m a s s s p e c t r o m e t r y DFS Magnetic Sector GC/MS Designed for Highest Sensitivity Analyze Detect Measure Control DFS MAGNETIC SECTOR GC/MS 2DFS Magnetic Sector GC/MS In continuation of a 50 year

More information

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm 26.1645 165.91 33.267 Thermo Scientific Q Exactive rbitrap LC-MS/MS System Unmatched Confidence for Quan/Qual Analyses Identify Quantify Confirm Quanfirmation \ kwän-f r-'m -shän\ n 1 : the ability to

More information

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery Application Note: 3 Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery Yoko Yamagishi, Thermo Fisher Scientific, C-2F 3-9

More information

Thermo Scientific ITQ Series Quadrupole Ion Trap GC/MS n

Thermo Scientific ITQ Series Quadrupole Ion Trap GC/MS n c h r o m a t o g r a p h y Thermo Scientific ITQ Series Quadrupole Ion Trap GC/MS n Optimized for Real-World Sample Analysis Dependable performance in ion trap technology Unmatched sensitivity in full-scan

More information

Complete Materials Deformulation Using TGA-IR

Complete Materials Deformulation Using TGA-IR Application Note: 51694 Complete Materials Deformulation Using TGA-IR Michael Bradley, Thermo Fisher Scientific, Madison, WI, USA Key Words Feedstock Supplies Finished Products Multi-component Search OMNIC

More information

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis Alessandro Santato, 1 Doug Hamilton, 1 Jan Wijbrans, 2 Claudia Bouman 1 1 Thermo Fisher Scientific, Bremen, Germany 2 VU University Amsterdam,

More information

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis A. Caruso, M. Santoro, P. Magni, S. Pelagatti, and R. Facchetti Thermo Fisher Scientific, Milan,

More information

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Che Jinshui, 1 Deng Guifeng, 1 Liang Lina, 1 and Aaron Kettle, 2 1 Thermo Fisher Scientific (China)

More information

Compounding insights Thermo Scientific Compound Discoverer Software

Compounding insights Thermo Scientific Compound Discoverer Software Compounding insights Thermo Scientific Compound Discoverer Software Integrated, complete, toolset solves small-molecule analysis challenges Thermo Scientific Orbitrap mass spectrometers produce information-rich

More information

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 000 Elemental Analyzer Dr. Liliana Krotz and Dr. Guido Giazzi Thermo Fisher Scientific, Milan, Italy

More information

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness Application Note: 52252 The Raman Spectroscopy of Graphene and the Determination of Layer Thickness Mark Wall, Ph.D., Thermo Fisher Scientific, Madison, WI, USA Key Words DXR Raman Microscope 2D Band D

More information

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method Xiang He and Marta Kozak ThermoFisher Scientific, San Jose, CA,

More information

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer Improved Screening for 2 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer Mary lackburn, Jia Wang, Jonathan eck, Charles Yang, Dipankar Ghosh, Thermo Fisher Scientific, San Jose, C,

More information

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications Xiaodong Liu and Christopher Pohl; Thermo Fisher Scientific, Sunnyvale, CA Overview Review mixed-mode column technology

More information

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Scientific LTQ Orbitrap Velos

More information

IN QUALITATIVE ANALYSIS,

IN QUALITATIVE ANALYSIS, IN QUALITATIVE ANALYSIS, YOU VE ALWAYS HAD TO CHOOSE BETWEEN ACCURACY AND THROUGHPUT. NOW THERE S NO REASON TO ever have to. WATERS QUALITATIVE ANALYSIS solutions Waters ACQUITY UPLC System with the Waters

More information

A Platform to Identify Endogenous Metabolites Using a Novel High Performance Orbitrap MS and the mzcloud Library

A Platform to Identify Endogenous Metabolites Using a Novel High Performance Orbitrap MS and the mzcloud Library A Platform to Identify Endogenous Metabolites Using a Novel High Performance Orbitrap MS and the mzcloud Library Junhua Wang, 1 David A. Peake, 1 Robert Mistrik, 2 Yingying Huang 1 1 Thermo Fisher Scientific

More information

MassHunter TOF/QTOF Users Meeting

MassHunter TOF/QTOF Users Meeting MassHunter TOF/QTOF Users Meeting 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks

More information

Automated and accurate component detection using reference mass spectra

Automated and accurate component detection using reference mass spectra TECHNICAL NOTE 72703 Automated and accurate component detection using reference mass spectra Authors Barbara van Cann 1 and Amit Gujar 2 1 Thermo Fisher Scientific, Breda, NL 2 Thermo Fisher Scientific,

More information

Targeted protein quantification

Targeted protein quantification Targeted Quantitative Proteomics Targeted protein quantification with high-resolution, accurate-mass MS Highly selective Very sensitive Complex samples HR/AM A more complete quantitative proteomics picture

More information

Measurement of Metabolic Stability Using SIM and Identification of Metabolites by Data Dependent Full-Scan MS/MS and CNL Scanning

Measurement of Metabolic Stability Using SIM and Identification of Metabolites by Data Dependent Full-Scan MS/MS and CNL Scanning Application Note: 349 Measurement of Metabolic Stability Using SIM and Identification of Metabolites by Data Dependent Full-Scan MS/MS and CNL Scanning Peter B Ehmer, Ethirajulu Kantharaj, Katie De Wagter,

More information

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization Thermo Scientific K-Alpha + XPS Spectrometer Fast, powerful and accessible chemical analysis for surface and thin film characterization X-ray Photoelectron Spectroscopy Quantitative, chemical identification

More information

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS Kate Comstock, Tim Stratton, Hongxia (Jessica) Wang, and Yingying Huang

More information

Stephen McDonald, Mark D. Wrona, Jeff Goshawk Waters Corporation, Milford, MA, USA INTRODUCTION

Stephen McDonald, Mark D. Wrona, Jeff Goshawk Waters Corporation, Milford, MA, USA INTRODUCTION Combined with a Deep Understanding of Complex Metabolic Routes to Increase Efficiency in the Metabolite Identification Search Stephen McDonald, Mark D. Wrona, Jeff Goshawk Waters Corporation, Milford,

More information

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance Michael D. Jones, Marian Twohig, Karen Haas, and Robert S. Plumb Waters Corporation,

More information

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3 Second-Generation Electron Transfer Dissociation (ETD) on the Thermo Scientific Orbitrap Fusion Mass Spectrometer with Improved Functionality, Increased Speed, and Improved Robustness of Data Christopher

More information

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS Application Note: 10018 Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS Thermo Fisher Scientific, Austin, TX, USA Key Words Direct Sample Probe Single Quadrupole GC/MS Drugs of Abuse

More information

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems Yan Liu, Zhongqing Lu, and Chris Pohl; Thermo Fisher Scientific, Sunnyvale, CA USA Overview

More information

Identifying Disinfection Byproducts in Treated Water

Identifying Disinfection Byproducts in Treated Water Identifying Disinfection Byproducts in Treated Water Jonathan D. Byer, LEC Corporation; Saint Joseph, Michigan USA Susan D. Richardson, University of South Carolina; Columbia, South Carolina USA 1. Introduction

More information

Multi-residue analysis of pesticides by GC-HRMS

Multi-residue analysis of pesticides by GC-HRMS An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict

More information

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces Application Note: 52287 XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces Brian R. Strohmeier, Thermo Fisher Scientific, Madison, WI, USA

More information

Direct Analysis using Paper-Spray Mass Spectrometry: Method Development for the Rapid Screening of Drugs of Abuse for Forensic Toxicology

Direct Analysis using Paper-Spray Mass Spectrometry: Method Development for the Rapid Screening of Drugs of Abuse for Forensic Toxicology Direct Analysis using Paper-Spray Mass Spectrometry: Method Development for the Rapid Screening of Drugs of Abuse for Forensic Toxicology Maria C. Prieto Conaway, 1 Nicholas E. Manicke, 2 Marta Kozak 1

More information

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis Technical Overview Introduction Metabolomics studies measure the relative abundance of metabolites

More information

Reaxys Medicinal Chemistry Fact Sheet

Reaxys Medicinal Chemistry Fact Sheet R&D SOLUTIONS FOR PHARMA & LIFE SCIENCES Reaxys Medicinal Chemistry Fact Sheet Essential data for lead identification and optimization Reaxys Medicinal Chemistry empowers early discovery in drug development

More information

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada) Quantitation and Identification of Pharmaceuticals and Personal Care Products (PPCP) in Environmental Samples using Advanced TripleTOF MS/MS Technology André Schreiber AB SCIEX Concord, Ontario (Canada)

More information

ARL OPTIM X X-Ray Fluorescence Spectrometer. Optimized Performance for Your Application

ARL OPTIM X X-Ray Fluorescence Spectrometer. Optimized Performance for Your Application e l e m e n t a l a n a l y s i s ARL OPTIM X X-Ray Fluorescence Spectrometer Optimized Performance for Your Application Analyze Detect Measure Control ARL OPTIM X Optimized Performance for Your Application

More information

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Marian Twohig, Michael D. Jones, Dominic Moore, Peter Lee, and Robert Plumb Waters Corporation, Milford, MA, USA APPLICATION

More information

Making Sense of Differences in LCMS Data: Integrated Tools

Making Sense of Differences in LCMS Data: Integrated Tools Making Sense of Differences in LCMS Data: Integrated Tools David A. Weil Agilent Technologies MassHunter Overview Page 1 March 2008 How Clean is our Water?... Page 2 Chemical Residue Analysis.... From

More information

An Evaluation of Various High-Resolution, Accurate-Mass Scan Modes for In Vitro Drug Discovery Screening

An Evaluation of Various High-Resolution, Accurate-Mass Scan Modes for In Vitro Drug Discovery Screening An Evaluation of Various High-Resolution, Accurate-Mass Scan Modes for In Vitro Drug Discovery Screening Jonathan McNally, 1 Nicholas Duczak Jr., 1 Patrick Bennett, 1 Francois Espourteille, and Maciej

More information

Finnigan LCQ Advantage MAX

Finnigan LCQ Advantage MAX www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Finnigan LCQ Advantage MAX The Finnigan LCQ Advantage MAX ion trap mass spectrometer

More information

MassHunter Software Overview

MassHunter Software Overview MassHunter Software Overview 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks A

More information

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Andrea Caruso and Massimo Santoro, Thermo Fisher Scientific, Milan, Italy Application Note 1316 Key

More information

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency Anthony Edge, 1 Luisa Pereira, 1 Dafydd Milton 1 and Andrew Shalliker 2 1 Thermo Fisher Scientific,

More information

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision ARGUS VI Static Vacuum Mass Spectrometer Static Vacuum ARGUS VI Multicollection Low Volume Precision Based on more than 20 years of experience in noble gas mass spectrometry instrumentation, we have developed

More information

Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer

Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer Charles Yang and Dipankar Ghosh, Thermo Fisher Scientific, San Jose, CA Olaf

More information

Key Words Q Exactive Focus, Orbitrap, veterinary drugs, small molecule HRAM quantitation, small molecule HRAM screening, UHPLC, vdia

Key Words Q Exactive Focus, Orbitrap, veterinary drugs, small molecule HRAM quantitation, small molecule HRAM screening, UHPLC, vdia Variable Data-Independent Acquisition (vdia) Delivers High Selectivity and Sensitivity in Combined Targeted and Untargeted Analyses for Small Molecules Olaf Scheibner 1, Markus Kellmann 1, Charles Yang

More information

Thermo Finnigan LTQ. Specifications

Thermo Finnigan LTQ. Specifications IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Finnigan LTQ Specifications

More information

Monitoring Protein PEGylation with Ion Exchange Chromatography

Monitoring Protein PEGylation with Ion Exchange Chromatography Monitoring Protein PEGylation with Ion Exchange Chromatography Peter Yu, Deanna Hurum, Jinyuan (Leo) Wang, 2 Terry Zhang, 2 and Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, CA; 2 Thermo Fisher Scientific,

More information

HILIC Method Development in a Few Simple Steps

HILIC Method Development in a Few Simple Steps HILIC Method Development in a Few Simple Steps Monica Dolci, Luisa Pereira, Dafydd Milton and Tony Edge Thermo Fisher Scientific, Runcorn, Cheshire, UK Overview This poster presents a systematic approach

More information

HYPHENATED TECHNOLOGY GUIDE

HYPHENATED TECHNOLOGY GUIDE HYPHENATED TECHNOLOGY GUIDE TABLE OF CONTENTS TG-IR...3 Hiden Analytical MS Systems for TG-MS...4 TG-MS...5 TG-GC/MS...6 TG-IR-GC/MS...8 HYPHENATED TECHNOLOGY GUIDE Coupling, or hyphenating, two instruments

More information

Application Note. Authors. Abstract. Introduction. Environmental

Application Note. Authors. Abstract. Introduction. Environmental Using a Chlorine Filter for Accurate-Mass Data Analysis of Environmental Samples Application Note Environmental Authors Imma Ferrer and E. Michael Thurman Center for Environmental Mass Spectrometry University

More information

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD Massimo Santoro, 1 Sergio Guazzotti, 1 Danilo Pierone, 2 Alexandre Souza, 3 Jaqueline Lorena,

More information

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System Claire Bramwell-German, Elliott Jones and Daniel Lebre AB SCIEX, Foster City, California

More information

Thermo Scientific GasBench II

Thermo Scientific GasBench II MASS SPECTROMETRY Thermo Scientific GasBench II Universal On-Line Gas Preparation and Introduction System for Isotope Ratio MS Product Specifications The Thermo Scientific GasBench II is an innovative

More information

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer ARGUS VI HELIX SFT Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer Static Vacuum HELIX SFT Low Volume Multicollection High Mass Resolution 3 Based on more than 20 years of experience in

More information

Analyst Software. Peptide and Protein Quantitation Tutorial

Analyst Software. Peptide and Protein Quantitation Tutorial This document is provided to customers who have purchased AB Sciex equipment to use in the operation of such AB Sciex equipment. This document is copyright protected and any reproduction of this document

More information

HYPHENATED TECHNOLOGY GUIDE

HYPHENATED TECHNOLOGY GUIDE HYPHENATED TECHNOLOGY GUIDE TABLE OF CONTENTS TG-IR...3 Hiden Analytical MS Systems for TG-MS...4 TG-MS...5 TG-GC/MS...6 TG-IR-GC/MS...8 HYPHENATED TECHNOLOGY GUIDE Coupling, or hyphenating, two instruments

More information

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate Michael D. Jones, Xiang Jin Song, Robert S. Plumb, Peter J. Lee, and

More information

High-Resolution Accurate-Mass (HRAM) Phthalate Screening using Direct Analysis in Real Time (DART) Ambient Ionization

High-Resolution Accurate-Mass (HRAM) Phthalate Screening using Direct Analysis in Real Time (DART) Ambient Ionization igh-resolution Accurate-Mass (RAM) Phthalate Screening using Direct Analysis in Real Time (DART) Ambient Ionization Catharina Crone, 1 Markus Kellmann, 1 Yue Xuan, 1 Elizabeth Crawford 2 1 Thermo Fisher

More information

Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry

Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry Cristian Cojocariu and Paul Silcock Thermo Fisher Scientific, Runcorn,

More information