1 m a s s s p e c t r o m e t r y Thermo Scientific irm-gc/ms Technology Get More Information from Your GC Samples Environmental Studies Forensics and Doping Control Ecology and Metabolic Studies Geochemistry and Petrology Food and Flavor Control Part of Thermo Fisher Scientific

2 Thermo Scientific irm-gc/ms Get more Information from your GC Samples... The Thermo Scientific irm-gc/ms is the first fully integrated irm-gc/ms system which is operated like a GC/MS. The new Thermo Scientific GC IsoLink unit integrates the Thermo Scientific TRACE GC Ultra gas chromatograph with the Thermo Scientific DELTA V isotope ratio mass spectrometer into one easy-to-use unit. The isotope ratios of all compounds in a GC application can now be monitored with precision of better than 2 ppm ( at%). The GC IsoLink unit incorporates the knowledge and experience of an installed base of more than 800 irm-gc/ms systems. All injection techniques and detector systems including Thermo Scientific GC/MS analyzers can be an integrated part of the irm-gc/ms system creating the most powerful analytical tool set. Target compounds in environmental forensics Persistent Organic Pollutants POPs Volatile Organic Compounds VOCs PAHs and PCBs Hydrocarbons in petroleum products and sediments Tracers and metabolites in ecosystems Lipids and fatty acids Amino acids Carbohydrates Biomarkers in biogeochemistry Alkanes and alkenes Hopanes Natural gas Authenticity control of food and flavors Terpenes and terpenoids in essential oils Fatty acids Drugs and explosives in forensic investigation Amphetamines Xanthines Nitrobenzenes 2

3 Structural Elucidation by GC/MS Separation by High Resolution GC 13 C / 12 C Isotopic Fingerprints by irm-gc/ms...by adding irm-gc/ms Isotope ratio monitoring-gc/ms Chemical and physical processes can change the natural isotope composition of organic compounds. The carbon, nitrogen, oxygen and hydrogen isotope ratios preserve a trace to these events in every molecule of a compound. These isotope signatures reveal information not accessible in any other way. This includes the origin of a compound, its synthesis pathway, conditions at its formation, sometimes even a substrate can be discovered. Paleoclimatic and diagenetic conditions can be resolved by the compound specific isotope analysis of biomarkers. Metabolic pathways can be unraveled by using isotopic tracers with lowest artificial isotope enrichment or with a distinctly different natural abundance. While GC/MS provides information on structural elucidation and compound quantitation, isotope ratio monitoring GC/MS (irm-gc/ms) reveals the history and origin of compounds by reading their isotopic signature with ultrahigh precision. Small variations of the natural isotope abundances cannot be detected with GC/MS systems. Only the combination of a GC and an isotope ratio mass spectrometer is capable of routinely achieving the required precision. This combination allows to determine the isotope ratios of all individual compounds in a complex mixture. All fields of application using GC and GC/MS can benefit from isotope ratio monitoring GC/MS. Isotopic fingerprints analyzed by irm-gc/ms may still provide information where classical GC/MS methods based on compound quantitation cannot. 3

4 Thermo Scientific irm-gc/ms Get more Information from your GC Samples... Compound specific isotope analysis of 13 C, 15 N, 18 O, and 2 H All GC-volatile compounds Analysis in the picomole range One automated sequence for 13 C, 15 N and 2 H determination High GC performance due to true capillary design Fully automated and maintenance-free operation Self-diagnosis and determination of system parameters Combination of quadrupole MS with irm-gc/ms TriPlus autosampler, ConFlo IV universal interface, GC IsoLink unit and Trace GC Ultra gas chromatograph. Doping Control: Prolong Detection of Testosterone Administration Analysis and Confirmation of Synthetic Testosterone Synthetic testosterone has a different isotope ratio than natural, endogenous testosterone. Therefore doping can be detected by comparing an athlete s testosterone isotope ratio with the isotope ratio of its endogenous precursors, e.g. cholesterol. This is much more sensitive and specific than monitoring compound ratios such as the testosterone/epitestosterone ratio. *Data courtesy of German Sports University Cologne, Germany, Center for Preventive Doping Research/Institute of Biochemistry. Comparison of urinary T/E ratios and δ 13 C testosterone values determined by irm-gc/ms after ingestion of 40 mg testosterone-undecanoate.* 4

5 GC/MS analyzes the ionized molecule and its fragments for quantitation and structural elucidation. irm-gc/ms enhances all isotope information by converting the compounds into simple gases, such as CO 2, N 2, H 2 or CO. The new GC IsoLink unit eliminates the complexity of this conversion and for the first time allows automatic switching between elements, controlling all aspects of the conversion....by adding irm-gc/ms Ecology and Metabolic Studies: Explore Complex Ecosystems Elucidation of Metabolic Pathways The isotope ratios of substrates, metabolites, and biomarkers are used to explore complex ecosystems with respect to structures of food chains, sources of compounds, detection of species involved in specific processes. Artificially and naturally labeled compounds in combination with irm-gc/ms analysis enable direct identification of species, elucidation of pathways and turnover rates. These concepts do apply to all biological applications with the focus on dietary and life conditions, migration patterns, position in food webs, metabolic processes and diseases. Amplitude (mv) Methyl Palmitate Methyl Stearate m/z 2 m/z Time (s) δ 2 H [ ] Fatty Acid Methyl Esther (FAME) analysis of dog plasma samples. 5

6 Thermo Scientific irm-gc/ms Principle of irm-gc/ms The separation power of capillary GC is now combined with the high precision of Isotope Ratio MS using the new GC IsoLink unit for compound specific isotope analysis of 13 C/ 12 C, 15 N/ 14 N, 18 O/ 16 O and D/H. Each organic compound eluting from the GC column is converted into simple gases when traversing one of the capillary microreactors. Two conversion techniques are applied: Quantitative high temperature combustion for 13 C and 15 N determination converts compounds into CO 2, N 2 and H 2 O at up to 1450 C. The H 2 O formed in the oxidation process is removed on-line and maintenance-free. Injector Oxidation 1100 C Quantitative high temperature pyrolysis for D/H and 18 O/ 16 O determination converts organic H to H 2 at 1450 C and organic O to CO at 1280 C in inert and reductive capillary reactors. Because quantitative conversion is achieved no additional clean up is required. Fully automated computer control directs the GC flow into the combustion or the pyrolysis reactor which allows for the first time the analysis of 13 C, 15 N and 2 H within one batch of sequences. This new feature makes irm-gc/ms as easy to operate as classical GC/MS systems. Open Split He+CO 2 Isotope Ratio MS High Temperature Pyrolysis 1450 C Quadrupole MS GC Column Get more Information from your GC Samples Environmental Forensics: Reveal the Origin of Samples Tracing Oil Spills by Isotope Fingerprints The molecular and the isotopic fingerprints of crude oils and refined petroleum products differ according to their origin and thermal maturity. The molecular fingerprint of such products changes when exposed to the environment due to physical and chemical processes, losing the link to original sources. In contrast, the isotopic fingerprint of oils does not alter during environmental degradation. Isotopic composition [ ] original cargo oil related shoreline residue bird feathers unrelated shoreline residue C16 C17 C18 C19 C21 C22 C23 C24 C25 C27 C29 C30 δ 13 C [ ] analysis by irm-gc/ms allows to keep the link between weathered residues and the source of oil pollution. ** ** Data courtesy of L. Mazeas, and H. Budzinski, Institut des Sciences Moléculaires (ISM), CNRS Laboratoire de Physico-et-Toxico-Chimie de L Environnement, Talence, France. 6

7 Thermo Scientific Isodat Software Suite for irm-gc/ms The irm-gc/ms system is fully automated and controlled by the Isodat software suite. This program is focused on continuous routine analyses with a fast setup of all methods and sequences. When coupled to a GC autosampler, the system can be operated fully unattended for high sample throughput and high productivity. All GC injection techniques and additional GC detectors are fully supported. The irm-gc/ms does not require any user interaction during operation. Automated system parameter control, data evaluation and report generation make irm-gc/ms as easy-to-use as standard GC/MS. The Thermo Scientific irm-gc/ms technology can also be hyphenated with the Thermo Scientific DSQ II single quadrupole GC/MS for simultaneous isotope and structural elucidation using the Isodat software suite and Thermo Scientific Xcalibur data system software. Thermo Scientific Isodat software suite. by adding irm-gc/ms Biogeochemistry: Read Geological Archives Reconstructing Paleoenvironmental Conditions The hydrogen isotopic composition of individual n-alkanes and acyclic isoprenoid alkanes in crude oils is controlled by biosynthetic precursors, source water and post-depositional processes. Oils derived from source rocks still retain a strong signature of the hydrogen isotopic compositions of source organic matter and source water. This indicates that 13 C/ 12 C and D/H values can be used for oil-source correlation and for paleoenvironmental reconstructions. 2 [V] 3/ C pristane D/H Ratio Trace H 2 Trace C phytane Time (s) δ 2 H [ ] of alkanes with GC separation of C 17 / pristane and C 18 / phytane. 7

8 Installation Requirements In addition to these offices, Thermo Fisher Scientific maintains a network of representative organizations throughout the world. Power 3-phase 230/400 V -10% + 6%, fused 16 A/phase (single-phase optional), 50/60 Hz, dedicated line voltage must be free of spikes. Thermo Scientific Instruments for irm-gc/ms GC IsoLink unit ConFlo IV universal interface TRACE GC Ultra gas chromatograph TriPlus autosampler DELTA V isotope ratio MS Supplies Helium carrier gas Reference and regeneration gases Compressed air > 400 kpa (> 50 psi) Thermo Scientific columns and consumables Thermo Scientific irm-gc/ms Unit Setup and Dimensions 81 cm (32 inches) Literature Sessions A.L., J. Sep. Sci. 2006, 29, Benson S., et al., Forensic Sci. Int., 2006, 157, Mazeas L., Budzinski H., J. Environ. Sci. Technol. 2002, 36, 2, Boschker H.T.S., Middelburg J.J., FEMS Microbiology Ecology 2002, 40, Li M., et al., Organic Geochemistry 2001, 32, Hilkert A.W., et al., Rapid Commun. Mass Spectrom. 1999, 13, Horning S., et al., In: Schänzer W., et al., Recent advances in doping analysis (4). Sport und Buch Strauß, Köln, 1997, Juchelka D., Mosandl A., Pharmazie 51 (6), Matthews D.E., Hayes J.M., Anal. Chem. 1978, 50, For publications and application data in your field of application, please contact our product specialists cm (22 inches) 92 cm (36 inches) Africa-Other analyze.sa@thermo.com Australia analyze.au@thermo.com Austria analyze.at@thermo.com Belgium analyze.be@thermo.com Canada analyze.ca@thermo.com China analyze.cn@thermo.com Denmark analyze.dk@thermo.com Europe-Other analyze.emea@thermo.com Finland / Norway/ Sweden analyze.se@thermo.com France analyze.fr@thermo.com Germany analyze.de@thermo.com India analyze.in@thermo.com Italy analyze.it@thermo.com Japan analyze.jp@thermo.com Latin America analyze.la@thermo.com Middle East analyze.emea@thermo.com Netherlands analyze.nl@thermo.com New Zealand analyze.au@thermo.com Russia/CIS analyze.emea@thermo.com South Africa analyze.sa@thermo.com Spain analyze.es@thermo.com Switzerland analyze.ch@thermo.com UK analyze.uk@thermo.com USA analyze.us@thermo.com Thermo Fisher Scientific (Bremen) GmbH Management System Registered to ISO 9001:2008 Thermo Fisher Scientific, San Jose, CA USA is ISO Certified. 2008, 2010 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. BR30149_E 09/10C

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS m a s s s p e c t r o m e t r y Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS Fully Automated Multi-Element Isotope Analysis for C, N, S, O, H Food Testing Forensics Environmental Analysis

More information

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer m a s s s p e c t r o m e t r y Finnigan TC/EA High Temperature Conversion Elemental Analyzer Analyze Detect Measure Control Finnigan TC/EA High Temperature Conversion Elemental Analyzer Finnigan TC/EA

More information

MetWorks Metabolite Identification Software

MetWorks Metabolite Identification Software m a s s s p e c t r o m e t r y MetWorks Metabolite Identification Software Enabling Confident Analysis of Metabolism Data Part of Thermo Fisher Scientific MetWorks Software for the Confident Analysis

More information

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS Thermo Scientific ConFlo IV Universal Interface Continuous Flow Interface Isotope Ratio MS 3 ConFlo IV Universal Interface for Continuous Flow Isotope Ratio MS The development of Continuous Flow carrier

More information

Thermo Scientific LC IsoLink

Thermo Scientific LC IsoLink m a s s s p e c t r o m e t r y Thermo Scientific LC IsoLink The Link from HPLC to Isotope Ratio Mass Spectrometry Carbohydrates Amino Acids, Nucleotides Organic Acids Pharmaceuticals Part of Thermo Fisher

More information

of mass spectrometry

of mass spectrometry Thermo Scientific 253 Ultra High resolution isotope ratio MS Discover a new world of mass spectrometry Paleoclimatology Atmospheric science Biogeochemistry Petrology Discover the isotopic anatomy of molecules

More information

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis A. Caruso, M. Santoro, P. Magni, S. Pelagatti, and R. Facchetti Thermo Fisher Scientific, Milan,

More information

Thermo Scientific TPDRO 1100 Advanced Catalyst Characterization

Thermo Scientific TPDRO 1100 Advanced Catalyst Characterization s u r f a c e a n a l y s i s Thermo Scientific TPDRO 11 Advanced Catalyst Characterization For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption Metal supported catalysts Oil industry

More information

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 000 Elemental Analyzer Dr. Liliana Krotz and Dr. Guido Giazzi Thermo Fisher Scientific, Milan, Italy

More information

TPDRO 1100 Advanced Catalyst Characterization. For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption

TPDRO 1100 Advanced Catalyst Characterization. For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption s u r f a c e a n a l y s i s TPDRO 11 Advanced Catalyst Characterization For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption Analyze Detect Measure Control TPDRO 11 Advanced

More information

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer Reiko Kiyonami, Mary Blackburn, Andreas FR Hühme: Thermo Fisher

More information

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer m a s s s p e c t r o m e t r y Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer Reset Your Expectations Part of Thermo Fisher Scientific Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer

More information

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry O. Scheibner, 1 P. van Baar, 2 F. Wode, 2 U. Dünnbier, 2 K. Akervik, 3 J. Humphries, 3 M. Bromirski 1

More information

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS Daniel Kutscher, 1 Jörg Bettmer, 2 Torsten Lindemann, 1 Shona McSheehy-Ducos, 1 Lothar Rottmann 1 1 Thermo Fisher Scientific, Germany 2

More information

Thermo Scientific DELTA V Advantage DELTA V Plus

Thermo Scientific DELTA V Advantage DELTA V Plus m a s s s p e c t r o m e t r y Thermo Scientific DELTA V Advantage DELTA V Plus The Next Generation Isotope Ratio MS Part of Thermo Fisher Scientific Thermo Scientific DELTA V Advantage DELTA V Plus Thermo

More information

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Olaf Scheibner and Maciej Bromirski Thermo Fisher Scientific, Bremen, Germany Overview Purpose: Improve the performance

More information

Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap

Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap m a s s s p e c t r o m e t r y Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap World's fastest and most sensitive ion trap mass spectrometer Part of Thermo Fisher Scientific Thermo Scientific

More information

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer Application ote: 54 Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap rbitrap Hybrid Mass Spectrometer Kate Comstock, Yingying Huang; Thermo Fisher Scientific,

More information

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis Tim Stratton 1, Yingying Huang 1, Katianna Pihakari 1, Ian Acworth 2, and Michael Weber 2 1 Thermo Fisher Scientific,

More information

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS Jason Lai, Jia Wang, Brad Hart, Pavel Aronov, Kristine Van Natta, Marta Kozak, Jorge Valdivia, Andy Jacobs, Haibo

More information

LTQ XL Linear Ion Trap Mass Spectrometer More Structural Information with MS n

LTQ XL Linear Ion Trap Mass Spectrometer More Structural Information with MS n m a s s s p e c t r o m e t r y LTQ XL Linear Ion Trap Mass Spectrometer More Structural Information with MS n Part of Thermo Fisher Scientific SUPERIR I TRAP TECHLGY From the leader in Ion Trap Mass Spectrometry,

More information

Thermo Scientific GasBench II

Thermo Scientific GasBench II MASS SPECTROMETRY Thermo Scientific GasBench II Universal On-Line Gas Preparation and Introduction System for Isotope Ratio MS Product Specifications The Thermo Scientific GasBench II is an innovative

More information

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use Shih-Tse Jason Lai, Jia Wang, Brad Hart, Kristine Van Natta, Marta Kozak, Jorge Valdivia, Haibo Wang,

More information

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput Yi Zhang 1, Zhiqi Hao 1, Markus Kellmann 2 and Andreas FR. Huhmer

More information

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD Massimo Santoro, 1 Sergio Guazzotti, 1 Danilo Pierone, 2 Alexandre Souza, 3 Jaqueline Lorena,

More information

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery Metabolite Stability Screening and Hotspot Metabolite Identification by Combining High-Resolution, Accurate-Mass Nonselective and Selective Fragmentation Tim Stratton, Caroline Ding, Yingying Huang, Dan

More information

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry Olaf Scheibner, 1 Patrizia van Baar, 2 Florian Wode, 2 Uwe Dünnbier, 2 Kristi Akervik, 3 Jamie Humphrie,

More information

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap Dirk Nolting and Andreas Wieghaus Thermo Fisher Scientific, Bremen, Germany Overview Purpose: Characterize the rate

More information

Thermo Scientific TRITON Thermal Ionization MS. Thermo Scientific NEPTUNE Multicollector ICP-MS. High Resolution Multicollector Mass Spectrometers

Thermo Scientific TRITON Thermal Ionization MS. Thermo Scientific NEPTUNE Multicollector ICP-MS. High Resolution Multicollector Mass Spectrometers m a s s s p e c t r o m e t r y Thermo Scientific TRITON Thermal Ionization MS Thermo Scientific NEPTUNE Multicollector ICP-MS High Resolution Multicollector Mass Spectrometers Part of Thermo Fisher Scientific

More information

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method Xiang He and Marta Kozak ThermoFisher Scientific, San Jose, CA,

More information

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy Introduction to Fourier Transform Infrared Spectroscopy Introduction What is FTIR? FTIR stands for Fourier transform infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR

More information

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Andrea Caruso and Massimo Santoro, Thermo Fisher Scientific, Milan, Italy Application Note 1316 Key

More information

Fast, Effective XPS Point Analysis of Metal Components

Fast, Effective XPS Point Analysis of Metal Components Application Note: 52297 Fast, Effective XPS Point Analysis of Metal Components Chris Baily and Tim Nunney, Thermo Fisher Scientific, East Grinstead, West Sussex, UK Key Words K-Alpha Auto-Analysis Multi-Spectrum

More information

LCQ Fleet Ion Trap LC/MS n Exceptional Analytical Value

LCQ Fleet Ion Trap LC/MS n Exceptional Analytical Value m a s s s p e c t r o m e t r y LCQ Fleet Ion Trap LC/MS n Exceptional Analytical Value Part of Thermo Fisher Scientific LCQ Fleet Ion Trap LC/MS n Unbeatable Rapid and Reliable Detection for Every Lab

More information

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer Defining quality standards for the analysis of solid samples Redefine your quality standards for the elemental analysis of solid samples

More information

Finnigan TSQ Quantum Discovery MAX

Finnigan TSQ Quantum Discovery MAX m a s s s p e c t r o m e t r y Finnigan TSQ Quantum Discovery MAX Round-the-clock productivity Analyze Detect Measure Control Lit Finnigan Sheet TSQ White Quantum Head Discovery MAX Extraordinary Value

More information

ApplicationNOTE Abstract

ApplicationNOTE Abstract Abstract It has long been known that a range of non-native, stable, saturated hydrocarbon biomarkers present in crude oil extracts could be used to identify the original facie from which the oil was formed.

More information

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis Alessandro Santato, 1 Doug Hamilton, 1 Jan Wijbrans, 2 Claudia Bouman 1 1 Thermo Fisher Scientific, Bremen, Germany 2 VU University Amsterdam,

More information

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Che Jinshui, 1 Deng Guifeng, 1 Liang Lina, 1 and Aaron Kettle, 2 1 Thermo Fisher Scientific (China)

More information

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems Yan Liu, Zhongqing Lu, and Chris Pohl; Thermo Fisher Scientific, Sunnyvale, CA USA Overview

More information

High-Field Orbitrap Creating new possibilities

High-Field Orbitrap Creating new possibilities Thermo Scientific Orbitrap Elite Hybrid Mass Spectrometer High-Field Orbitrap Creating new possibilities Ultrahigh resolution Faster scanning Higher sensitivity Complementary fragmentation The highest

More information

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness Application Note: 52252 The Raman Spectroscopy of Graphene and the Determination of Layer Thickness Mark Wall, Ph.D., Thermo Fisher Scientific, Madison, WI, USA Key Words DXR Raman Microscope 2D Band D

More information

DFS Magnetic Sector GC/MS

DFS Magnetic Sector GC/MS m a s s s p e c t r o m e t r y DFS Magnetic Sector GC/MS Designed for Highest Sensitivity Analyze Detect Measure Control DFS MAGNETIC SECTOR GC/MS 2DFS Magnetic Sector GC/MS In continuation of a 50 year

More information

Finnigan TRACE DSQ GC/MS

Finnigan TRACE DSQ GC/MS m a s s s p e c t r o m e t r y Finnigan TRACE DSQ GC/MS Discover Unmatched Sensitivity, Performance and Value Full-scan sensitivity for the demanding environmental analysis Proven performance for difficult

More information

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration Zhang Xuebin 1, Yu Chongtian 1, Liang Lina 1, Hans-Joachim Huebschmann 2, Thermo Fisher Scientific Shanghai, 1 China,

More information

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency Anthony Edge, 1 Luisa Pereira, 1 Dafydd Milton 1 and Andrew Shalliker 2 1 Thermo Fisher Scientific,

More information

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy molecular spectroscopy Introduction to Fourier Transform Infrared Spectroscopy Part of Thermo Fisher Scientific Introduction What is FT-IR? FT-IR stands for Fourier Transform InfraRed, the preferred method

More information

for XPS surface analysis

for XPS surface analysis Thermo Scientific Avantage XPS Software Powerful instrument operation and data processing for XPS surface analysis Avantage Software Atomic Concentration (%) 100 The premier software for surface analysis

More information

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3 Second-Generation Electron Transfer Dissociation (ETD) on the Thermo Scientific Orbitrap Fusion Mass Spectrometer with Improved Functionality, Increased Speed, Christopher Mullen, 1 Lee Earley, 1 Jean-Jacques

More information

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery Application Note: 3 Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery Yoko Yamagishi, Thermo Fisher Scientific, C-2F 3-9

More information

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces Application Note: 52287 XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces Brian R. Strohmeier, Thermo Fisher Scientific, Madison, WI, USA

More information

EA-IRMS: Fast and Precise Isotope Analysis of Liquids on a Delta V Isotope Ratio MS with a High Temperature Conversion Elemental Analyzer

EA-IRMS: Fast and Precise Isotope Analysis of Liquids on a Delta V Isotope Ratio MS with a High Temperature Conversion Elemental Analyzer APPLICATION NOTE EA-IRMS: Fast and Precise Isotope Analysis of Liquids on a Delta V Isotope Ratio MS with a High Temperature Conversion Elemental Analyzer AN30180 Oliver Kracht, Andreas Hilkert, Thermo

More information

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer Improved Screening for 2 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer Mary lackburn, Jia Wang, Jonathan eck, Charles Yang, Dipankar Ghosh, Thermo Fisher Scientific, San Jose, C,

More information

is given for the isotopic fingerprinting methodology.

is given for the isotopic fingerprinting methodology. ADVANTAGES OF COUPLING THE FINGERPRINTING AND BIOCHEMICAL TECHNIQUES IN CONTAMINATION ANALYSIS By Ilaria Pietrini Ph. D. Student at Politecnico di Milano ilaria.pietrini@mail.polimi.it Introduction Thousands

More information

Finnigan TRITON Finnigan NEPTUNE. High Resolution Multicollector Mass Spectrometers

Finnigan TRITON Finnigan NEPTUNE. High Resolution Multicollector Mass Spectrometers m a s s s p e c t r o m e t r y Finnigan TRITON Finnigan NEPTUNE High Resolution Multicollector Mass Spectrometers Analyze Detect Measure Control Finnigan TRITON / Finnigan NEPTUNE High Resolution Multicollector

More information

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm 26.1645 165.91 33.267 Thermo Scientific Q Exactive rbitrap LC-MS/MS System Unmatched Confidence for Quan/Qual Analyses Identify Quantify Confirm Quanfirmation \ kwän-f r-'m -shän\ n 1 : the ability to

More information

Direct Analysis using Paper-Spray Mass Spectrometry: Method Development for the Rapid Screening of Drugs of Abuse for Forensic Toxicology

Direct Analysis using Paper-Spray Mass Spectrometry: Method Development for the Rapid Screening of Drugs of Abuse for Forensic Toxicology Direct Analysis using Paper-Spray Mass Spectrometry: Method Development for the Rapid Screening of Drugs of Abuse for Forensic Toxicology Maria C. Prieto Conaway, 1 Nicholas E. Manicke, 2 Marta Kozak 1

More information

Thermo Scientific ITQ Series Quadrupole Ion Trap GC/MS n

Thermo Scientific ITQ Series Quadrupole Ion Trap GC/MS n c h r o m a t o g r a p h y Thermo Scientific ITQ Series Quadrupole Ion Trap GC/MS n Optimized for Real-World Sample Analysis Dependable performance in ion trap technology Unmatched sensitivity in full-scan

More information

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis Thermo Scientific Pesticide Explorer Collection Start-to-finish workflows for pesticide analysis Comprehensive Pesticide Analysis Solutions Pesticide Explorer Collection Selection table Lab Profile Routine

More information

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites Robert Heintz, Mark Wall, Jennifer Ramirez, Stephan Woods Thermo Fisher Scientific, Madison WI Overview Purpose:

More information

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF Analysis of Biomarkers in Crude Oil Using the Agilent 7 GC/Q-TOF Application Note Petrochemical and Environmental Authors Frank David Research Institute for Chromatography, Kennedypark 6, B-85 Kortrijk,

More information

IN QUALITATIVE ANALYSIS,

IN QUALITATIVE ANALYSIS, IN QUALITATIVE ANALYSIS, YOU VE ALWAYS HAD TO CHOOSE BETWEEN ACCURACY AND THROUGHPUT. NOW THERE S NO REASON TO ever have to. WATERS QUALITATIVE ANALYSIS solutions Waters ACQUITY UPLC System with the Waters

More information

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications Xiaodong Liu and Christopher Pohl; Thermo Fisher Scientific, Sunnyvale, CA Overview Review mixed-mode column technology

More information

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS anion-exchange column is designed for the fast analysis of inorganic

More information

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization Thermo Scientific K-Alpha + XPS Spectrometer Fast, powerful and accessible chemical analysis for surface and thin film characterization X-ray Photoelectron Spectroscopy Quantitative, chemical identification

More information

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS Application Note: 10018 Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS Thermo Fisher Scientific, Austin, TX, USA Key Words Direct Sample Probe Single Quadrupole GC/MS Drugs of Abuse

More information

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS Kate Comstock, Tim Stratton, Hongxia (Jessica) Wang, and Yingying Huang

More information

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

Mass Spectral Studies of Polypropylene Chromatographic Well Plates Mass Spectral Studies of Polypropylene Chromatographic Well Plates Brian King, Thermo Fisher Scientific, Runcorn, Cheshire, UK Detlev Lennartz, Thermo Fisher Scientific, Langerwehe, Germany White Paper

More information

HILIC Method Development in a Few Simple Steps

HILIC Method Development in a Few Simple Steps HILIC Method Development in a Few Simple Steps Monica Dolci, Luisa Pereira, Dafydd Milton and Tony Edge Thermo Fisher Scientific, Runcorn, Cheshire, UK Overview This poster presents a systematic approach

More information

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION A purpose-built collection of the best-inclass components for forensic toxicology Whether you re challenged to present reliable and secure forensic sample

More information

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Anila I. Khan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 243 Key Words TraceGOLD fast GC analysis

More information

A Platform to Identify Endogenous Metabolites Using a Novel High Performance Orbitrap MS and the mzcloud Library

A Platform to Identify Endogenous Metabolites Using a Novel High Performance Orbitrap MS and the mzcloud Library A Platform to Identify Endogenous Metabolites Using a Novel High Performance Orbitrap MS and the mzcloud Library Junhua Wang, 1 David A. Peake, 1 Robert Mistrik, 2 Yingying Huang 1 1 Thermo Fisher Scientific

More information

Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry

Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry Cristian Cojocariu and Paul Silcock Thermo Fisher Scientific, Runcorn,

More information

GC-MS-IRMS: Undisputable results by coupling of GC-IRMS with high-resolution mass spectrometry for final confirmation in sports drug testing

GC-MS-IRMS: Undisputable results by coupling of GC-IRMS with high-resolution mass spectrometry for final confirmation in sports drug testing APPLICATION NOTE 30405 GC-MS-IRMS: Undisputable results by coupling of GC-IRMS with high-resolution mass spectrometry for final confirmation in sports drug testing Authors Dieter Juchelka, 1 Thomas Piper,

More information

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision ARGUS VI Static Vacuum Mass Spectrometer Static Vacuum ARGUS VI Multicollection Low Volume Precision Based on more than 20 years of experience in noble gas mass spectrometry instrumentation, we have developed

More information

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS Tomoko Vincent 1, Simon Lofthouse 2, Daniel Kutscher 1 and Shona McSheehy Ducos

More information

SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging

SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging Katerina Bousova, 1 Michal Godula, 2 Michele Suman 3 1 Thermo Fisher Scientific, Special Solutions

More information

Elemental Analysis: CHNS/O characterization of polymers and plastics

Elemental Analysis: CHNS/O characterization of polymers and plastics APPLICATION NOTE 0 Elemental Analysis: CHNS/O characterization of polymers and plastics Authors Introduction Dr. Liliana Krotz and Dr. Guido Giazzi Thermo Fisher Scientific, Milan, Italy The chemical composition

More information

High-Resolution Accurate-Mass (HRAM) Phthalate Screening using Direct Analysis in Real Time (DART) Ambient Ionization

High-Resolution Accurate-Mass (HRAM) Phthalate Screening using Direct Analysis in Real Time (DART) Ambient Ionization igh-resolution Accurate-Mass (RAM) Phthalate Screening using Direct Analysis in Real Time (DART) Ambient Ionization Catharina Crone, 1 Markus Kellmann, 1 Yue Xuan, 1 Elizabeth Crawford 2 1 Thermo Fisher

More information

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS Nanoparticle Characterization Via Single Particle Inductively Coupled Plasma Mass Spectrometry (spicp-ms) Using a Dedicated Plug-in for Qtegra ISDS Software Technical Note 43279 Daniel Kutscher, Julian

More information

Thermo Scientific 253 Plus 10 kv Isotope Ratio MS. Utilize the Gold Standard. in isotope ratio MS. Robustness Sensitivity Precision

Thermo Scientific 253 Plus 10 kv Isotope Ratio MS. Utilize the Gold Standard. in isotope ratio MS. Robustness Sensitivity Precision Thermo Scientific 253 Plus 1 kv Isotope Ratio MS Utilize the Gold Standard in isotope ratio MS Robustness Sensitivity Precision Utilize the Gold Standard in Isotope Ratio MS 2 The Thermo Scientific 253

More information

Screening Method for 30 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS

Screening Method for 30 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS Application Note: 514 Screening Method for 3 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS Yang Shi, Catherine Lafontaine, Thermo Fisher Scientific, Franklin,

More information

Monitoring Protein PEGylation with Ion Exchange Chromatography

Monitoring Protein PEGylation with Ion Exchange Chromatography Monitoring Protein PEGylation with Ion Exchange Chromatography Peter Yu, Deanna Hurum, Jinyuan (Leo) Wang, 2 Terry Zhang, 2 and Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, CA; 2 Thermo Fisher Scientific,

More information

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer Static Vacuum HELIX MC Plus Dynamic range Multi collection High mass resolution Based on more than

More information

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer ARGUS VI HELIX SFT Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer Static Vacuum HELIX SFT Low Volume Multicollection High Mass Resolution 3 Based on more than 20 years of experience in

More information

Complete Materials Deformulation Using TGA-IR

Complete Materials Deformulation Using TGA-IR Application Note: 51694 Complete Materials Deformulation Using TGA-IR Michael Bradley, Thermo Fisher Scientific, Madison, WI, USA Key Words Feedstock Supplies Finished Products Multi-component Search OMNIC

More information

Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases

Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases APPLICATION NOTE 42255 Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases Authors Dr. Liliana Krotz, Dr. Francesco

More information

Targeted protein quantification

Targeted protein quantification Targeted Quantitative Proteomics Targeted protein quantification with high-resolution, accurate-mass MS Highly selective Very sensitive Complex samples HR/AM A more complete quantitative proteomics picture

More information

Key Words Q Exactive Focus, Orbitrap, veterinary drugs, small molecule HRAM quantitation, small molecule HRAM screening, UHPLC, vdia

Key Words Q Exactive Focus, Orbitrap, veterinary drugs, small molecule HRAM quantitation, small molecule HRAM screening, UHPLC, vdia Variable Data-Independent Acquisition (vdia) Delivers High Selectivity and Sensitivity in Combined Targeted and Untargeted Analyses for Small Molecules Olaf Scheibner 1, Markus Kellmann 1, Charles Yang

More information

Characterization of petroleum samples via thermal analysis coupled to APCI FTMS

Characterization of petroleum samples via thermal analysis coupled to APCI FTMS Characterization of petroleum samples via thermal analysis coupled to APCI FTMS Abstract Thermal analysis, by means of a thermo balance (TG), was coupled to an atmospheric pressure chemical ionization

More information

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection Terri Christison, Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA Overview

More information

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM Application Note: 320 Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM Key Words Metabolism Study Structure Elucidation Metabolite ID Mass Frontier Chromatography

More information

Semi-Targeted Screening of Pharmaceutically- Related Contaminants in the Thames Tideway using LC-HRMS

Semi-Targeted Screening of Pharmaceutically- Related Contaminants in the Thames Tideway using LC-HRMS Semi-Targeted Screening of Pharmaceutically- Related Contaminants in the Thames Tideway using LC-HRMS Kelly Munro, 1 Anthony Edge, 2 Claudia Martins, 3 David Cowan 4 and Leon Barron 1 1 Analytical & Environmental

More information

Thermo Scientific HyperSep Dispersive SPE Products. Efficient sample preparation and clean-up using the QuEChERS Method

Thermo Scientific HyperSep Dispersive SPE Products. Efficient sample preparation and clean-up using the QuEChERS Method Thermo Scientific HyperSep Dispersive SPE Products Efficient sample preparation and clean-up using the QuEChERS Method The QuEChERS method overcomes the problems associated with time consuming, expensive

More information

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core

More information

Automated and accurate component detection using reference mass spectra

Automated and accurate component detection using reference mass spectra TECHNICAL NOTE 72703 Automated and accurate component detection using reference mass spectra Authors Barbara van Cann 1 and Amit Gujar 2 1 Thermo Fisher Scientific, Breda, NL 2 Thermo Fisher Scientific,

More information

Detection of Mycotoxins in Corn Meal Extract Using Automated Online Sample Preparation with Liquid Chromatography-Tandem Mass Spectrometry

Detection of Mycotoxins in Corn Meal Extract Using Automated Online Sample Preparation with Liquid Chromatography-Tandem Mass Spectrometry Detection of Mycotoxins in Corn Meal Extract Using Automated Online Sample Preparation with Liquid Chromatography-Tandem Mass Spectrometry Yang Shi, Catherine Lafontaine, Timothy B. Haney, and François

More information

An Evaluation of Various High-Resolution, Accurate-Mass Scan Modes for In Vitro Drug Discovery Screening

An Evaluation of Various High-Resolution, Accurate-Mass Scan Modes for In Vitro Drug Discovery Screening An Evaluation of Various High-Resolution, Accurate-Mass Scan Modes for In Vitro Drug Discovery Screening Jonathan McNally, 1 Nicholas Duczak Jr., 1 Patrick Bennett, 1 Francois Espourteille, and Maciej

More information

δ 13 C of DIC and carbonate samples: comparison of traditional mass spectrometry methods with an infrared spectrometry method

δ 13 C of DIC and carbonate samples: comparison of traditional mass spectrometry methods with an infrared spectrometry method APPLICATION NOTE 30486 δ 13 C of DIC and carbonate samples: comparison of traditional mass spectrometry methods with an infrared spectrometry method Authors Danijela Smajgl, 1 Magda Mandic, 1 Dirk Nürnberg,

More information

VGA-100 Instrument Detection Limits and Linearity

VGA-100 Instrument Detection Limits and Linearity VGA-100 Instrument Detection Limits and Linearity The VGA-100 is the world s first benchtop vacuum ultraviolet (VUV) spectrometer for gas chromatography (GC). It is a universal GC detector that provides

More information