1 Isotech Journal of Thermometry Index Volumes 1 10, 1990 to 2000 Welcome to the Isotech Journal of Thermometry Fundamentals of Thermometry Part 1 Temperature Scales Practical Calibration of Thermometers on the ITS-90 Platinum Resistance Thermometers as Interpolation Standards for the ITS-90 Fundamentals of Thermometry Part 2 Fixed Points Standard Platinum Resistance Thermometers calibrations on the ITS-90; how to specify and order International Equivalence of thermometer calibration, testing and certification Improvements in Metrological Apparatus Evaluation of the Gallium Melting Point by a two cell comparison An MS-DOS computer program for the interpolation of the ITS-90 Fundamentals of Thermometry Part 3 Standard Platinum Resistance Thermometers The Platinum Resistance Thermometers of C.H. Meyers (Historic Reprint) Coiled Filament Platinum Resistance Thermometers Open Cell, Sealed Cells, Slim Cells The Heat Pipe and its use in Thermometer Calibration Isothermal Heat Pipes and Pressure Controlled Furnaces Fundamentals of Thermometry Part 4 Standard Thermometers, Bridges and Measurements Cost of Calibration to the ITS-90 at various institutions Uncertainties in Temperature Measurement The Gallium Watchdog (in quality assurance of measurement) New Developments and Discoveries - high temperature platinum resistance thermometers Review: About Words - available metrology vocabularies Fundamentals of Thermometry Part 5 Industrial Platinum Resistance Thermometers
2 Common Errors in Industrial Temperature Measurement I blame the Mother in Law (Evolution of Fluid Bed Calibration Bath) The Water Triple Point and Gallium Point in Secondary Laboratories in Germany Comparison Calibration at the Boiling Point of Nitrogen or Argon A Caution from Phil Metz News of a New Metrology Society (Slovak Metrological Society) Melting Point and Triple Point Measurements of gallium on the IPTS-68 (Historic Reprint) Fundamentals of Thermometry Part 6 Thermistors R vs. T Table for Industrial Resistance Thermometers on ITS-90 Equilibrium Temperatures of Some Secondary Fixed Points on the ITS-90 Metrology Standards in Europe and the prospect of one in America A Technical Guide and Standard Practice for the Qualification and Use of Water Triple Point Cells Review: New mathematical software and a book from the American Institute of Physics Industrial Resistance Thermometers at High Temperatures The Gallium Watchdog in Action (in quality assurance of measurement) Thermoelectric Modules How R(tpw) and R(ga) tell us the condition of high temperature resistance thermometers News of NIST A Technical Guide and Standard Practice for the Realizing the Melting Point of Gallium Fundamentals of Thermometry Part 7 Melting and Freezing Equilibria, phase diagrams, cryoscopic constant Two Notes on Metal Freeze Point Cells A Model for Maintaining Standards to Temperature in a Company with Satellite Operations and we invoiced NAMAS R vs. T Table for Industrial Resistance Thermometers (Revisited) The West European Calibration Cooperation and other accreditation systems
3 The Robert Berry Papers, an introduction Effect of Oxidization on Pr Resistance Thermometers (Historic Reprint) Study of Multilayer Oxidization by Electrical Resistance Technique (Historic Reprint) An Example of Berry's Oxides News: A Thermometry Course at the Van Swinden Laboratory News: an announcement from EAL (European Cooperation for the Accreditation of Laboratories) Do you know where your ice point is tonight? Harold f. Stimson remembered The Measurement of some Thermal Properties of Water (Historic Reprint) High Temperature SPRTs: The Next Generation News: Yamari Industries receives Accreditation in Japan News: Sandia dedicates New Primary Standards Laboratory News: Henry Sostmann receives Wildhack Award from NCSL Thermocouple Thermometry Reproducibility of some Water Triple Point Cells A European Intercomparison of Metal Freeze Point Cells The North American Metrology Cooperation (NORAMET) Traceability - A Concept in Evolution Fundamentals of Thermometry Part 8 Radiation Thermometry High Temperature Standard Resistance Thermometers in Saudi Arabia Surface Temperature Measurement using Contact Thermometry Metal Block Baths: Calibrated or Not? Isotech on the World Wide Web Noise Thermometry Notes from the NAMAS Laboratory
4 NAMAS under a New Management Structure A Proposal to Merge CIPM and CIML, Special Supplement Thermocouples: Traceability, Instability, Inhomogeneity Notes from the NAMAS Laboratory ASTM STD E Standard Guide for the use of Water Triple Point Cells, Critical Review The Jarret-Isotech Water Triple Point Cell The Proposed Merger of CIPM and CIML, Revisited Traceability and Qualification of ITS-90 Fixed Point Cells Thermometric Fixed Points and the development of the Gallium Melting Point Proliferation of Error from an Incorrect Water Triple Point Practical Reference Temperatures using Melting Point Techniques Freezing and Melting Points in Slim Cells Isotech's New Primary Laboratory Isotech Dedicates new Primary Laboratory HT-SPRTs, Origins and Developments The Distributed Nature of EMF in Thermocouples and its Consequences Thermistor Development at the Yellow Springs Instrument Co. Agreement between IPTS-68, ITS-90 and the IEC Algorithm for Industrial PRTs Easy Dry Ice 9.1 Volume 9 No. 1 Trenchant Quotations 9.1 Volume 9 No. 1 Journal Reader Survey 9.1 Volume 9 No. 1 The Education of a Pyrometrist 9.1 Volume 9 No. 1 How Many Digits are Significant in SPRT Coefficients 9.1 Volume 9 No. 1 Propagation of errors form the Water Triple Point 9.1 Volume 9 No. 1 Electrical Noise Reduction in High Temperature Furnaces
5 9.1 Volume 9 No Volume 9 No. 1 Notes from the UKAS (NAMAS) Laboratory CSIRO Handbooks of Temperature Measurement, Special Book Review Erratum Vol 9 No. 1, Thermistor Equation Sostmann-Isotech Gallium Cell: Plateau Duration, Oxygen Effects, Useful Life Expectancy Recalibration Intervals of SPRTs Depths of Immersion Propagation of Error from the ITS-90 Fixed Points New Developments in the Ayries Fluidised Furnace Necrology - Dr. Thomas, Dr. Maas Special Announcement The Northern Temperature Primary Laboratory, A Unique NAMAS Accredited Facility How Low Frequency and DC Electrical Measurements Limit Temperature Calibration Accuracies New Resistance Thermometer and its use in Verifying Very Pure ITS-90 Fixed Points Optimal Realizations of some Fixed Points of the ITS-90 Completely Automated Fixed Points from the ITS-90 for Industry, POTTS Ambient Temperature Measurement in Metrology Thermocouple Audits Water: an article to wet the appetite Index, Chronological, Subject Traceability in Primary, Secondary and Industrial Laboratories
NIST CERTIFICATION OF ITS-90 FIXED-POINT CELLS FROM K TO K: METHODS AND UNCERTAINTIES
NIST CERTIFICATION OF ITS-90 FIXED-POINT CELLS FROM 83.8058 K TO 1234.93 K: METHODS AND UNCERTAINTIES Gregory F. Strouse National Institute of Standards and Technology, Gaithersburg, Maryland, USA ABSTRACT
More informationSIMPLE LIQUID NITROGEN COMPARATOR MODEL 461 User Maintenance Manual/Handbook
SIMPLE LIQUID NITROGEN COMPARATOR MODEL 461 User Maintenance Manual/Handbook Isothermal Technology Limited, Pine Grove, Southport, PR9 9AG, England Tel: +44 (0)1704 543830 Fax: +44 (0)1704 544799 Internet:
More informationIntroduction to Blackbody Sources
Introduction to s This section contains dedicated blackbody sources for low uncertainty calibration of infrared thermometers. A range of portable primary blackbody sources combine high emissivity with
More informationEuropean Association of National Metrology Institutes
European Association of National Metrology Institutes EURAMET GUIDELINES ON TEMPERATURE: Extrapolation of SPRT calibrations below the triple point of argon, 83.8058 K, and traceability in baths of liquid
More informationCERTIFICATE OF CALIBRATION
Page 1 of 5 CERTIFICATE OF CALIBRATION 1K Thermistor CERTIFICATE NO.: MANUFACTURER: Measurement Specialties DATE OF CALIBRATION: 26-Apr-17 TC15249 CUSTOMER: AMBIENT TEMPERATURE: (21 ± 3) C JOB NUMBER:
More informationCalibration of temperature sensors within Length Standard Section of NMIJ
Calibration of temperature sensors within Length Standard Section of NMIJ Dr. Akiko Hirai Length Standard Section National Metrology Institute of Japan (NMIJ) 1 Contents Temperature measurement system
More informationCalibration of Temperature Block Calibrators
European Association of National Metrology Institutes Calibration of Temperature Block Calibrators EURAMET cg-13 Version 2.0 (03/2011) Previously EA-10/13 Calibration Guide EURAMET cg-13 Version 2.0 (03/2011)
More informationInternational Temperature Scale of 1990 From Wikipedia, the free encyclopedia
International Temperature Scale of 1990 From Wikipedia, the free encyclopedia The International Temperature Scale of 1990 (ITS-90) published by the Consultative Committee for Thermometry (CCT) of the International
More informationNew Thermometer Guidance Document from AASHTO Accreditation Program. Maria Knake Asphalt Binder ETG Meeting May 10, 2018
New Thermometer Guidance Document from AASHTO Accreditation Program Maria Knake Asphalt Binder ETG Meeting May 10, 2018 Background Mercury reduction initiatives have hastened the need to find suitable
More informationg/cm³ DAkkS Calibration Laboratory for Temperature and Density High-precision calibration for temperature and density
High-precision calibration for temperature and density g/cm³ F K C DAkkS Calibration Laboratory for Temperature and Density Accredited DAkkS laboratory (D-K-15223-01-00) for temperature and density measurements
More informationTemperature. 3
Temperature In 1848, Sir William Thomson (Lord Kelvin) stated the zero principle of dynamics. This principle enabled him to define thermodynamic temperature and to establish an objective method of measuring
More informationCCT/10-21 Extrapolation of the ITS-90 down to the boiling point of nitrogen from the triple point of argon
CCT/10-21 Extrapolation of the ITS-90 down to the boiling point of nitrogen from the triple point of argon Tohru Nakano and Osamu Tamura National Metrology Institute of Japan (NMIJ), AIST Tsukuba, Japan
More informationGood practice guide containing experimental results and recommendations for the selection, preparation and calibration of the temperature sensors
Good practice guide containing experimental results and recommendations for the selection, preparation and calibration of the temperature sensors 1. Scope... 2 2. Introduction... 2 3. Selection of thermocouples
More informationDemonstrating Competency and Equivalency of Two Commercial SPRT Calibration Facilities
Demonstrating Competency and Equivalency of Two Commercial SPRT Calibration Facilities T. J. Wiandt 1,2 1 Fluke Corporation, Hart Scientific Division, American Fork, Utah United States. 2 E-mail: tom.wiandt@hartscientific.com
More informationREPORT to the CCT on Comparison COOMET. T-K3 (COOMET theme No. 285/RU-а/03) Final Report
REPORT to the CCT on Comparison COOMET. T-K3 (COOMET theme No. 285/RU-а/03) Final Report REGIONAL COMPARISONS OF THE NATIONAL STANDARDS OF TEMPERATURE IN THE RANGE FROM THE TRIPLE POINT OF WATER TO THE
More informationMICHELL TECHNOLOGIES FOR MOISTURE. Calibration. General Principles & Theory, Equipment Considerations
Calibration General Principles & Theory, Equipment Considerations Metrological Principles Accurate but not Precise Calibration A A+ Correction = Precise but not Accurate Correction B Ref Std (Radio Link
More informationMODEL FOR UNCERTAINTY ESTIMATION IN COMPARISON CALIBRATION OF THERMOCOUPLES
XVII IMEKO World Congress Metrology in the 3rd Millennium June 7, 003, Dubrovnik, Croatia MODEL OR UNCERTAINTY ESTIMATION IN COMPARISON CALIBRATION O THERMOCOUPLES Georges Bonnier, Eliane Renaot, DavorZvizdic,
More informationThe Fundamentals of Moisture Calibration
The Fundamentals of Moisture The following guide will provide you with a basic knowledge of humidity calibration, help you to understand your requirements and select an appropriate solution. 1 Why Humidity
More informationINTERNATIONAL COMPARISON OF PLATINUM RESISTANCE THERMOMETERS BETWEEN CHILE AND ECUADOR
INTERNATIONAL COMPARISON OF PLATINUM RESISTANCE THERMOMETERS BETWEEN CHILE AND ECUADOR M. Araya 1, D. Almeida 2 1 National Laboratory of Temperature of Chile, LCPNT, Santiago, Chile 2 Ecuadorian Standardization
More informationInfrared Thermometer Calibration A Complete Guide
Infrared Thermometer Calibration A Complete Guide Application note With proper setup and planning, infrared calibrations can be accurate. The steps outlined below should be followed to perform accurate
More information2.1. Accuracy, n- how close the indication of the thermometer is to the true value.
AASHTO Accreditation Policy and Guidance on Thermometer Selection and Records Revised: January 25, 2018 Revision #: 0 1. Objective 1.1. The purpose of this document is to clearly define acceptance criteria
More informationThe International Temperature Scale of 1990
The International Temperature Scale of 199 metrologia Springer-Verlag 199 This copy incorporates textual corrections detailed in Metrologia 27, 17 (199) The International Temperature Scale of 199 (ITS-9)
More informationEA-10/13. EA Guidelines on the Calibration of Temperature Block Calibrators. Publication Reference PURPOSE
Publication Reference EA-10/13 EA Guidelines on the Calibration of Temperature Block Calibrators PURPOSE This document been produced by EA to improve the harmonisation in the calibration of temperature
More informationCALIBRATION AND ACCURACY OF SECONDARY STANDARD PRT'S TO THE ITS-90
CALIBRATION AND ACCURACY OF SECONDARY STANDARD PRT'S TO THE ITS-9 Presenter: Thomas J. Wiandt Southern California Edison 73 Fenwick Lane Westminster, CA 92683 Telephone: (714) 895-443 Fax: (714) 895-686
More informationCombined method for establishment and dissemination of the international temperature scale
DISSERTATIONES PHYSICAE UNIVERSITATIS TARTUENSIS 86 RIHO VENDT Combined method for establishment and dissemination of the international temperature scale DISSERTATIONES PHYSICAE UNIVERSITATIS TARTUENSIS
More informationCALIBRATION. Calibration. General Principles & Theory, Equipment Considerations. Copyright Caltech 2014
Calibration General Principles & Theory, Equipment Considerations Metrological Principles Accurate but not Precise Calibration A A+ Correction = Precise but not Accurate Correction B Ref Std (Radio Link
More informationA SPRT Intercomparison at Hg, TPW, Ga, Sn and Zn ITS-90 Fixed Points between PTB and LATU with PTB as Pilot Laboratory
A SPRT Intercomparison at Hg, TPW, Ga, Sn and Zn ITS-90 Points between PTB and LATU with PTB as Pilot Laboratory O. Robatto, Departamento de Metrología Científica, Laboratorio Tecnológico del Uruguay(LATU),
More information1 THE CONCEPT OF TEMPERATURE
1 THE CONCEPT OF TEMPERATURE 1 1.1 Historical Perspective, 2 1.2 Early Definitions of Temperature, 9 1.3 A Simple Qualitative Definition of Temperature, 10 1.4 Units of Temperature for Various Temperature
More informationA Case for Periodic Calibration or Verification of RTDs
A Case for Periodic Calibration or Verification of RTDs If you are experiencing audio problems please call the teleconference number below Phone 650-479-3208 Access code 668 676 434 Your Host and Presenter
More informationTemperature Measurement
MECE 3320 Measurements & Instrumentation Temperature Measurement Dr. Isaac Choutapalli Department of Mechanical Engineering University of Texas Pan American Introduction Temperature is one of the most
More informationEA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement
Publication Reference EA-10/11 EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical PURPOSE This document has been produced by EA as a means of giving advice for calibrating
More informationHow do you really know what the temperature is? Michael de Podesta
How do you really know what the temperature is? Michael de Podesta TECO: Madrid September 2016 GOLDEN RULE OF TALKS One talk: one thing This Talk: TWO THINGS! Thing 1: The definitions of the SI units of
More informationCertificate of Accreditation to ISO/IEC 17025:2005
United States Department of Commerce National Institute of Standards and Technology Certificate of Accreditation to ISO/IEC 17025:2005 NVLAP LAB CODE: 200508-0 Insco Metrology, Inc. Miami, FL is accredited
More informationME 365 EXPERIMENT 5 FIRST ORDER SYSTEM IDENTIFICATION APPLIED TO TEMPERATURE MEASUREMENT SYSTEMS
ME 365 EXPERIMENT 5 FIRST ORDER SYSTEM IDENTIFICATION APPLIED TO TEMPERATURE MEASUREMENT SYSTEMS Objectives: In this two week experiment, we will gain familiarity with first order systems by using two
More informationEstablishing traceability and estimating measurement uncertainty in physical, chemical and biological measurements
Establishing traceability and estimating measurement uncertainty in physical, chemical and biological measurements Experimental Design 8.2.2013 Doc. Martti Heinonen etunimi.sukunimi@mikes.fi Outline 1.
More informationArgon Triple-Point Device for Calibration of SPRTs
Int J Thermophys (2015) 36:229 239 DOI 10.1007/s10765-014-1768-0 Argon Triple-Point Device for Calibration of SPRTs B. Kołodziej H. Manuszkiewicz A. Szmyrka-Grzebyk L. Lipiński A. Kowal P. P. M. Steur
More informationCALIBRATION REPORT FOR THERMOHYDROMETER
CALIBRATION REPORT FOR THERMOHYDROMETER SAMPLE CUSTOMER S/N: XXXXX Report Number: Y205188 Page 1 of 5 Report No. Y205188 ICL CALIBRATION LABORATORIES, INC. ISO/IEC 17025 and ANSI/NCSL Z540-1 accredited
More informationTHE ENCYCLOPAEDIA THERMOMETRY
THE ENCYCLOPAEDIA OF THERMOMETRY Volume 1 Number 1, 1 s t Quarter 1990 THE ENCYCLOPAEDIA OF THERMOMETRY Volume 1 Number 1, 1 s t Quarter 1990 TABLE OF CONTENTS PAGE WELCOME TO THE ENCYCLOPAEDIA OF THERMOMETRY
More informationBUREAU INTERNATIONAL DES POIDS ET MESURES
BUREAU INTERNATIONAL DES POIDS ET MESURES Bilateral comparison of 1 Ω and 10 kω standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the SMD (Belgium) and the BIPM October 2017 Final
More informationCalibration of Thermocouples
European Association of National Metrology Institutes Calibration of Thermocouples EURAMET/cg-08/v.01 Previously EA-10/08 July 2007 Calibration Guide EURAMET/cg-08/v.01 CALIBRATION OF THERMOCOUPLES July
More informationThe Water Triple Point - A Reference Cell Close to the ITS-90 Value
The Water Triple Point - A Reference Cell Close to the ITS-90 Value By John P. Tavener & Anne Blundell. Northern Temperature Primary Laboratory., Pine Grove, Southport, Merseyside, PR9 9AG, England. Tel:
More informationEVALUATION OF THE ACCURACY OF A THERMOMETRIC RESISTANCE BRIDGE TO DIFFERENT VALUES OF ATMOSPHERIC PRESSURE
VALUATION OF TH ACCURACY OF A THRMOMTRIC RITANC BRIDG TO DIFFRNT VALU OF ATMOPHRIC PRUR Diego Almeida cuadorian tandards Institute, dalmeida@inen.gob.ec Abstract: The accuracy of a commercial thermometric
More informationApproximation of ITS-90 with High Temperature Thermometers up to 1085 C
Approximation of ITS-9 with High Temperature Thermometers up to 185 C N.P. Moiseeva, A.I. Pokhodun D. I. Mendeleyev Institute of Metrology, St. Petersburg, Russia Abstract. The upper limit of the ITS-9
More informationRADIOMETRIC COMPARISON BETWEEN A NATIONAL LABORATORY AND AN INDUSTRIAL LABORATORY
RADIOMETRIC COMPARISON BETWEEN A NATIONAL LABORATORY AND AN INDUSTRIAL LABORATORY Frank E. Liebmann, Tom Kolat, Michael J. Coleman and Thomas J. Wiandt Fluke Calibration 799 Utah Valley Drive, American
More informationI. Yang, C. H. Song, Y.-G. Kim & K. S. Gam
Cryostat for Fixed-Point Calibration of Capsule-Type SPRTs I. Yang, C. H. Song, Y.-G. Kim & K. S. Gam International Journal of Thermophysics Journal of Thermophysical Properties and Thermophysics and Its
More information(Refer Slide Time 3:35)
Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras Module 2 Lecture - 9 Temperature Measurement This will be lecture
More informationINTER-COMPARISONON TEMPERATURE MEASUREMENT USING FLUKE THERMOMETER MODEL 1502A
INTER-COMPARISONON TEMPERATURE MEASUREMENT USING FLUKE THERMOMETER MODEL 1502A Drs. Untung Merdijanto M.Si, Drs. Damianus Tri Heryanto, Drs. Kanton Lumban Toruan, M.Si, and Budi Santoso Agency for Meteorology,
More informationAPMP.T-K3.4: Key comparison of realizations of the ITS-90 over the range C to C
APMP.T-K3.4: Key comparison of realizations of the ITS-90 over the range -38.8344 C to 419.57 C Final report Prepared by. Joung (coordinator) and K. S. Gam Korea Research Institute of Standards and Science
More informationDocument No: TR 12 Issue No: 1
ESTIMATION OF THE UNCERTAINTY OF MEASUREMENT BY CALIBRATION LABORATORIES AND SPECIFICATION OF CALIBRATION AND MEASUREMENT CAPABILITY ON SCHEDULES OF ACCREDITATION Prepared by: SADCAS Technical Manage Approved
More informationLet s Get Digital: A Guide to Unraveling the Tangled World of Digital Thermometers
Let s Get Digital: A Guide to Unraveling the Tangled World of Digital Thermometers By Maria Knake, Laboratory Assessment Program Manager Posted: November 2011 So, You re Looking to Buy a Digital Thermometer?
More informationSTATUS OF THE WIGOS DEMONSTRATION PROJECTS
STATUS OF THE WIGOS DEMONSTRATION PROJECTS Demonstration Project Morocco Strengthening Moroccan RIC Capacities (Submitted by Rabia Merrouchi, National Meteorological Service of Morocco (DMN)) February
More informationTemperature Measurement
Temperature Measurement Temperature is one of the most common measurements What is Temperature? Intuitively understood as sensation of hot/cold Early Researchers: Galileo (1564-1642) Newton (1642-1727)
More informationCERTIFICATE OF CALIBRATION
CERTIFICATE OF CALIBRATION 12100 WEST 6TH AVE LAKEWOOD, CO 80228 ANAB AC-2489.02 Manufacturer: Ruska Instruments Corp. Model Number: 7250i : Pressure Calibrator Serial Number: 69718 ID: TE10768 As-Found:
More informationHigh Accuracy High Speed in Your Process
DX-Series Handheld Precision IR Thermometers EXERGEN C O R P O R A T I O N The Only Certified Accurate NIST Traceable Infrared Temperature Instruments in the World* High Accuracy High Speed in Your Process
More informationGood morning everyone, and welcome again to MSLs World Metrology Day celebrations.
Thank you Gavin.. Good morning everyone, and welcome again to MSLs World Metrology Day celebrations. The aim of this talk is to explain the changes that will be made with the change in the definition of
More informationIsothermal Technology Ltd
INDUSRIAL MEASUREMENS WIH VERY SHOR IMMERSION J. P. avener, D. Southworth, D. Ayres, N. Davies. Isothermal echnology Ltd lab@isotech.co.uk Abstract One major problem that keeps recurring is the request
More informationVersion 4.0 (09/2017) Version 3.0 (02/2015) Version 2.0 (03/2011) Version 1.0 (07/2007) EURAMET e.v. Bundesallee 100 D Braunschweig Germany
Guidelines on the Calibration of Temperature Block Calibrators Authorship and Imprint This document was developed by the EURAMET e.v., Technical Committee for Thermometry. Authors: Yves Hermier (LNE-INM,
More informationTheory and Design for Mechanical Measurements
Theory and Design for Mechanical Measurements Third Edition Richard S. Figliola Clemson University Donald E. Beasley Clemson University John Wiley & Sons, Inc. New York / Chichester / Weinheim / Brisbane
More informationA Sub-millikelvin Calibration Facility in the Range 0 C to 30 C
Int J Thermophys (2017) 38:37 DOI 10.1007/s10765-016-2171-9 TEMPMEKO 2016 A Sub-millikelvin Calibration Facility in the Range 0 C to 30 C R. Bosma 1 A. Peruzzi 1 R. Van Breugel 1 C. Bruin-Barendregt 1
More informationProper Platinum Resistance Thermometer Calibration Uncertainty Analysis
Proper Platinum Resistance Thermometer Calibration Uncertainty Analysis Thomas Wiandt Fluke Corporation, Hart Scientific Division NCSLI 2007 Session 8B 1 Introduction Uncertainty quantification is a primary
More informationINTERNATIONAL COMPARISON OF WATER TRIPLE POINT CELLS LEADING TO A MORE PRECISE DEFINITION OF THE KELVIN
INTERNATIONAL COMPARISON OF WATER TRIPLE POINT CELLS LEADING TO A MORE PRECISE DEFINITION OF THE KELVIN Michael Stock and Stéphane Solve Bureau International des Poids et Mesures (BIPM) Pavillon de Breteuil,
More informationHumidity Calibration Solutions
Instruments Humidity Solutions www.michell.com Instruments Humidity Solutions The Importance of Regular The reliable operation of a hygrometer and indeed any measuring instrument, can only be verified
More informationIMPLEMENTATION OF ETHANOL HEAT PIPE AT CETIAT
IMPLEMENTATION OF ETHANOL HEAT PIPE AT CETIAT JO Favreau 1, E Georgin 1, B Savanier 1, A. Merlone 2 1 CETIAT, 96100 Villeurbanne, France 2 INRIM, Torino, Italy Abstract. CETIAT is a calibration laboratory
More informationPut sufficient ice cubes into water (1 M) and wait for equilibrium (both exist) (1 M)
NAME : F.5 ( ) Marks: /70 FORM FOUR PHYSICS REVISION TEST on HEAT Allowed: 70 minutes This paper consists of two sections. Section A (50 marks) consists of the structure-type questions, and Section B (20
More informationCalibration capabilities at PTB for radiation thermometry, quantitative thermography and emissivity
14 th Quantitative InfraRed Thermography Conference Calibration capabilities at PTB for radiation thermometry, quantitative thermography and emissivity by I. Müller*, A. Adibekyan*, B. Gutschwager*, E.
More informationTemperature Measurement And Calibration Setup (TH1)
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2018 Temperature Measurement And Calibration Setup (TH1) Momin E. Abdalla University
More informationIMPROVING SOIL MEASUREMENTS FOR BOUNDARY LAYER RESEARCH
IMPROVING SOIL MEASUREMENTS FOR BOUNDARY LAYER RESEARCH Hannelore Bloemink, Jan Bijma Royal Netherlands Meteorological Institute (KNMI) Instrumentation Division P.O. Box 201, 3730 AE De Bilt, The Netherlands
More informationUNCERTAINTY ANALYSIS FOR LABORATORY ACCREDITATION. Peter B. Crisp. Fluke Precision Measurement Ltd, 52 Hurricane Way, Norwich, UK
UNCERTAINTY ANALYSIS FOR LABORATORY ACCREDITATION Peter B. Crisp Fluke Precision Measurement Ltd, 5 Hurricane Way, Norwich, UK Introduction NAMAS Accredited laboratories are required to follow recommended
More informationDevelopment of a Heat-Pipe-Based Hot Plate for Surface-Temperature Measurements
Int J Thermophys (2009) 30:257 264 DOI 10.1007/s10765-008-0495-9 Development of a Heat-Pipe-Based Hot Plate for Surface-Temperature Measurements L. Rosso N. Koneva V. Fernicola Published online: 12 August
More informationCRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TEMPERATURE METROLOGY
CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TEMPERATURE METROLOGY Approved By: Chief Executive Officer: Ron Josias Senior Manager: Mpho Phaloane Revised By: Field Manager: Neville Tayler Date
More informationINTERCOMPARISON OF WATER TRIPLE POINT CELLS FROM INTIBS AND INRIM 1. INTRODUCTION
METROLOGY AND MEASUREMENT SYSTEMS VOL. XV, NUMBER 4 (2008) A. SZMYRKA-GRZEBYK 1, A. KOWAL 1, L. LIPIŃSKI 1, PETER P. M. STEUR 2, R. DEMATTEIS 2 1 Institute of Low Temperature and Structure Research PAN,
More informationThe Development of a High-Temperature PRT Calibration Process Based On Dry- Block Calibrators
The Development of a High-Temperature PRT Calibration Process Based On Dry- Block Calibrators Michael Coleman Fluke Corporation, Temperature Calibration Division, American Fork, Utah, USA mike.coleman@fluke.com
More information(ii) the total kinetic energy of the gas molecules (1 mark) (iii) the total potential energy of the gas molecules (1 mark)
NAME : F.5 ( ) Marks: /70 FORM FOUR PHYSICS REVISION TEST on HEAT Allowed: 70 minutes This paper consists of two sections. Section A (50 marks) consists of the structure-type questions, and Section B (20
More informationWATER, ICE AND THE TRIPLE POINT
WATER, ICE AND THE TRIPLE POINT J. P. Tavener Isothermal Technology Ltd (Isotech), Pine Grove, Southport, Merseyside, PR9 9AG, England info@isotech.co.uk INTRODUCTION Water comprises Hydrogen and Oxygen
More informationSection 7. Temperature Measurement
Section 7 Temperature Measurement 7/25/2017 Engineering Measurements 7 1 Working Definition Temperature is a measure of the average kinetic energy of the molecules that make of a substance. After time,
More informationR SANAS Page 1 of 7
ESTIMATION OF THE UNCERTAINTY OF MEASUREMENT BY CALIBRATION LABORATORIES AND SPECIFICATION OF CALIBRATION AND MEASUREMENT CAPABILITY ON SCHEDULES OF ACCREDITATION Approved By: Chief Executive Officer:
More informationTraceability of temperature measurements in Estonia
116 Proceedings of the Estonian Academy of Sciences, 2013, 62, 2, 116 121 Proceedings of the Estonian Academy of Sciences, 2013, 62, 2, 116 121 doi: 10.3176/proc.2013.2.05 Available online at www.eap.ee/proceedings
More informationBUREAU INTERNATIONAL DES POIDS ET MESURES
BUREAU INTERNATIONAL DES POIDS ET MESURES Bilateral comparison of 1 Ω and 10 kω standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NIMT (Thailand) and the BIPM December 016 Final
More informationOptimization of Thermal Radiation Source for High Temperature Infrared Thermometer Calibration
Optimization of Thermal Radiation Source for High Temperature Infrared Thermometer Calibration Gavin McQuillan NLA T&M Conference Guateng, September 26-28, 2016 2011 Fluke Calibration 1 Outline Introduction
More information792A AC/DC Transfer Standard
92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1
More informationTemperature Measurements
Engineering 80 Spring 2015 Temperature Measurements SOURCE: http://www.eng.hmc.edu/newe80/pdfs/vishaythermdatasheet.pdf SOURCE: http://elcodis.com/photos/19/51/195143/to-92-3_standardbody to-226_straightlead.jpg
More information792A AC/DC Transfer Standard
92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1
More informationI. Introduction and Objectives
Calibration and Measurement of Temperatures using K, T-Type Thermocouples, and a Thermistor Ben Sandoval 1 8/28/2013 Five K and five T type thermocouples were calibrated using ice water, a hot bath (boiling
More informationAbstract. 1. Introduction
The importance of establishing a very-high temperature radiation thermometry measurement capability at the National Metrology Institute of South Africa (NMISA) Speaker: Dr Efrem K Ejigu National Metrology
More informationUncertainty Workshop: Overview of uncertainty factors in HTGHPs
Uncertainty Workshop: Overview of uncertainty factors in HTGHPs EMRP Final Stakeholder Meeting NPL, Teddington, United Kingdom 1 DIN/EU Standards for GHPs ISO 830:1991 Thermal insulation Determination
More informationHumidity Calibration Solutions
Humidity Calibration Solutions www.michell.com Humidity Calibration Solutions The Importance of Regular Calibration The reliable operation of a hygrometer and indeed any measuring instrument, can only
More informationTHERMOCOUPLE CHARACTERISTICS TRAINER
THERMOCOUPLE CHARACTERISTICS TRAINER (Model No : ) User Manual Version 2.0 Technical Clarification /Suggestion : / Technical Support Division, Vi Microsystems Pvt. Ltd., Plot No :75,Electronics Estate,
More information4. Thermometry. Temperature and Heat Flow Temperature Scales Thermometers
4. Thermometry Measuring temperature by sensation is very imprecise. That is why we need a temperature scale and a thermometer to measure temperature more accurately. Temperature and Heat Flow Temperature
More informationGeneral Accreditation Guidance. Liquid-in-glass thermometers selection, use and calibration
General Accreditation Guidance Liquid-in-glass thermometers selection, use and calibration January 2018 Copyright National Association of Testing Authorities, Australia 2013 This publication is protected
More informationINDIANA DEPARTMENT OF TRANSPORTATION OFFICE OF MATERIALS MANAGEMENT. VERIFYING THERMOMETERS ITM No T
1.0 SCOPE. INDIANA DEPARTMENT OF TRANSPORTATION OFFICE OF MATERIALS MANAGEMENT VERIFYING THERMOMETERS ITM No. 909-08T 1.1 This test method covers the procedure for a verification of scale accuracy of liquid-in-glass
More informationTotal radiation measurements of thermodynamic temperature
Total radiation measurements of thermodynamic temperature metrologia T. J. Quinn and J. E. Martin Abstract. The principles of total radiation thermometry as a method of primary thermometry are presented.
More informationThermometry. History. History 1/21/18. The art or science of temperature observation
Thermometry The art or science of temperature observation History No one person credited with the invention of the thermometer; developed over time Avicenna used this principal to show that hotness and
More informationPart Number Range Accuracy Printing WP * Probe Special User LDC with Page Logging included Feature Cal Backlight
Table of Contents Comparison Chart Introduction Temperature Indicators & Controllers Portable Infrared Printing/Logging Page O2 O3 O10 O14 O30 O33 O1 Part Number Range Accuracy Printing WP * Probe Special
More informationA61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012
Revision 1.2 October 15, 2012 PAGE II TABLE OF CONTENTS TABLE OF CONTENTS... 1 GUIDANCE...2 1.0 Introduction... 2 2.0 Uncertainty and Traceability... 2 3.0 Need for Traceability... 3 3.1 What does traceability
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Hards Laboratories cc, t/a Technology Solutions
More informationECNG3032 Control and Instrumentation I
sensor ECNG3032 Control and Instrumentation I Lecture 1 Temperature Sensors Sensors The sensor is the first element in the measurement system. Measurand Transducer Principle Excitation Signal Interface
More informationThe Redefinition of the Kelvin
5574ion of the Kelvin research-article2014 Michael de Podesta National Physical Laboratory, Teddington, UK michael.depodesta@npl.co.uk Measurement and Control 2014, Vol. 47(10) 323 328 Crown Copyright
More informationMeasurement & Uncertainty - Basic concept and its application
Measurement & Uncertainty - Basic concept and its application Feb. 7. 2012 JongOh CHOI (choijongoh@kriss.re.kr) Knowledge and measurement When you can measure what you are speaking about, and express it
More informationCONTENT 2. ORGANIZATION 3. SERVICES. instruments. (3)Activities of RIC Tsukuba
1 CONTENT 1. INTRODUCTION 2. ORGANIZATION 3. SERVICES (1)Quality assurance of meteorological instruments (2)Research and development (3)Activities of RIC Tsukuba 2 Meteorological Instruments Center (MIC)
More informationOptimization of Thermal Radiation Source for High Temperature Infrared Thermometer Calibration
Optimization of Thermal Radiation Source for High Temperature Infrared Thermometer Calibration Speaker/Author: Frank Liebmann, Fluke Calibration, 799 Utah Valley Dr., American Fork, Utah, 84003, USA. +1
More information