Geotechnical Data Report

Size: px
Start display at page:

Download "Geotechnical Data Report"

Transcription

1 Geotechnical Data Report Emergency Bridge Package 6 Richland County, South Carolina May 12, 2016 SCDOT Project ID.: P029942, P029943, P Terracon Project No L (Rev. 1) Prepared for: South Carolina Department of Transportation Columbia, South Carolina Prepared by: Terracon Consultants, Inc. Columbia, South Carolina

2 May 12, 2016 South Carolina Department of Transportation P.O. Box 191 Columbia, South Carolina Attn: Mr. Trapp Harris, P.E. Geotechnical Design Engineer DesignBuild Section Re: Geotechnical Data Report Emergency Bridge Package 6 Richland County, South Carolina Project ID.: P029942, P029943, P Terracon Project Number: 73100L (Rev. 1) Dear Mr. Harris: Terracon Consultants Inc. (Terracon) has completed the geotechnical exploration and testing services for the above referenced project. These services were conducted in general accordance with the SCDOT Scope of Services, dated April 1, This geotechnical data report presents the findings of the subsurface exploration and laboratory testing along with an overview of testing activities. 1.0 INTRODUCTION The South Carolina Department of Transportation (SCDOT) has contracted Terracon to perform subsurface exploration and laboratory testing for the replacement of three bridges along the SC 48 (Bluff Road) alignment in Richland County, South Carolina. The bridges to be replaced are as follows: Back Swamp (Pin # P029942) Cedar Creek (Pin # P029943) Dry Branch (Pin # P029944) The purpose this work is to develop information relative to subsurface soil and groundwater conditions at the end bent locations for the aforementioned bridge locations. This report presents the results of that work. No geotechnical recommendations are associated with the requested scope of study. The following sections of this report contain a summary of the activities our field exploration and laboratory testing. The logs of the soil test borings, CPT soundings, MASW arrays, the Site Location Map and the Boring Location Plans are included in Appendix A of this report. The results of the laboratory testing performed on soil samples obtained from the site during Terracon Consultants, Inc. 21 Clemson Road Columbia, South Carolina P [803] F [803] terracon.com

3 Geotechnical Data Report Emergency Bridge Package 6 Richland County, SC May 12, 2016 Terracon Project No L (Rev. 1) the field exploration are included in Appendix B of this report. Descriptions of the field exploration and laboratory testing are included in their respective appendices. 2.0 PROJECT DESCRIPTION The project sites are located along SC 48 (Bluff Road) in Richland County, SC and span Back Swamp, Cedar Creek, and Dry Branch. Site location and boring locations plans are presented in Appendix A of this report. It is our understanding that the project will include the demolition/removal of each existing bridge and will be replaced with a new structure on the existing or similar horizontal alignment. The existing bridges are multispan structures that are supported on a driven pile foundation system. The original structures appears to be supported on driven timber piles whereas subsequent widenings utilized PreStressed Concrete (PSC) piles. At the time of the field exploration, the surface of the stream flow was generally about feet below the existing bridge decks. 3.0 GEOTECHNICAL TESTING The geotechnical exploration for this project was performed between April 26 and May 3, The results of our field work and our associated laboratory testing is attached in appendixes A and B of this report. 3.1 Field Exploration Our field exploration at the site consisted of the following: Six (6) Standard Penetration Test (SPT) Borings (B1, B2, B3, B4, B, and B6) Six (6) Cone Penetration Test (CPT) Soundings (CPT1, CPT2, CPT3, CPT4, CPT, and CPT6) Geophysical testing consisting of three (3) Multichannel Analysis of Surface Waves (MASW) arrays (MASW1, MASW2, and MASW3) The shear wave velocity profile is provided in Appendix A for each bridge. The 0foot average shear wave velocity value shown on each profile is based on the data obtained below the fill embankment. The tests were performed at the locations requested by the SCDOT. A description of our testing methods and graphical logs outlining the soil conditions at each test location are presented in Appendix A. Test locations were established in the field by Terracon and surveyed by Construction Support Services, LLC, after completion. The rig set ups at the boring/sounding locations are provided in photographs in Appendix A. Responsive Resourceful Reliable 2

4 Geotechnical Data Report Emergency Bridge Package 6 Richland County, SC May 12, 2016 Terracon Project No L (Rev. 1) 3.2 Laboratory Testing The following laboratory tests were performed on the soil samples collected at the site: Thirty (30) Natural Moisture Content Tests (ASTM D2216) Eleven (11) Atterberg Limits Tests (ASTM D4318) Twenty Four (24) Material Finer than No. 200 by Washing (ASTM D114014) The scope of the laboratory testing frequency was determined by the SCDOT. The tested samples were chosen by Terracon to provide lithological information. The laboratory procedures and results of the laboratory tests are presented in Appendix B. 4.0 CLOSURE We appreciate the opportunity to be of service to you on this project. If you have any questions concerning this report or we may be of further service, please contact us. Sincerely, Terracon Consultants, Inc. Kenneth J. Zur, P.E. Phillip A. Morrison, P.E. Senior Geotechnical Engineer Geotechnical Department Manager SC Registration No SC Registration No Attachments Copies: Addressee (1 via ) File (1) Responsive Resourceful Reliable 3

5 APPENDIX A FIELD EXPLORATION Exhibit A1 Site Location Map Exhibits A2 A4 Boring Location Plans Exhibit A Field Testing Summary Exhibits A6 A8 MASW Results Exhibit A9 Field Testing Description Exhibit A Soil Description Terms Exhibit A11 to A16 Boring Logs Exhibits A17 A22 CPT Sounding Logs Exhibits A23 to A28 CPT Correlative Logs Exhibit A29 Photographic Log

6 BACK SWAMP BRIDGE CEDAR CREEK BRIDGE DRY BRANCH BRIDGE DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS NOT INTENDED FOR CONSTRUCTION PURPOSES SCALE IN FEET Project Mngr: Drawn By: Checked By: Approved By: KJZ PTK KJZ PAM Project No. Scale: File No. Date: 73100L AS SHOWN 73100L MAY 2016 Consulting Engineers and Scientists 21 CLEMSON ROAD COLUMBIA, SC29229 PH. (803) FAX. (803) SITE LOCATION MAP Emergency Bridge Package 6 SC 48 (Bluff Road) Richland County, South Carolina Exhibit A1

7 B1 CPT1 CPT2 B2 MASW1 EXPLANATION BORING LOCATION CONE PENETRATION TEST MULTICHANNEL ANALYSIS OF SURFACE WAVES DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS NOT INTENDED FOR CONSTRUCTION PURPOSES SCALE IN FEET Project Mngr: Drawn By: Checked By: Approved By: KJZ PTK KJZ PAM Project No. Scale: File No. Date: 73100L AS SHOWN 73100L MAY 2016 Consulting Engineers and Scientists 21 CLEMSON ROAD COLUMBIA, SC29229 PH. (803) FAX. (803) BORING LOCATION PLAN Emergency Bridge Package 6 SC 48 (Bluff Road) Back Swamp Bridge Richland County, South Carolina Exhibit A2

8 B3 B4 CPT3 CPT4 MASW2 EXPLANATION BORING LOCATION CONE PENETRATION TEST MULTICHANNEL ANALYSIS OF SURFACE WAVES DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS NOT INTENDED FOR CONSTRUCTION PURPOSES SCALE IN FEET Project Mngr: Drawn By: Checked By: Approved By: KJZ PTK KJZ PAM Project No. Scale: File No. Date: 73100L AS SHOWN 73100L MAY 2016 Consulting Engineers and Scientists 21 CLEMSON ROAD COLUMBIA, SC29229 PH. (803) FAX. (803) BORING LOCATION PLAN Emergency Bridge Package 6 SC 48 (Bluff Road) Cedar Creek Bridge Richland County, South Carolina Exhibit A3

9 B CPT CPT6 B6 MASW3 EXPLANATION BORING LOCATION CONE PENETRATION TEST MULTICHANNEL ANALYSIS OF SURFACE WAVES DIAGRAM IS FOR GENERAL LOCATION ONLY, AND IS NOT INTENDED FOR CONSTRUCTION PURPOSES SCALE IN FEET Project Mngr: Drawn By: Checked By: Approved By: KJZ PTK KJZ PAM Project No. Scale: File No. Date: 73100L AS SHOWN 73100L MAY 2016 Consulting Engineers and Scientists 21 CLEMSON ROAD COLUMBIA, SC29229 PH. (803) FAX. (803) BORING LOCATION PLAN Emergency Bridge Package 6 SC 48 (Bluff Road) Dry Branch Bridge Richland County, South Carolina Exhibit A4

10 Geotechnical Data Report Emergency Bridge Package 6 Richland County, SC May 12, 2016 Terracon Project No L (Rev. 1) Field Testing Summary Boring No. Location Offset Ground Elevation Test Northing Easting Latitude Longitude B1 WBL Lane Center B2 EBL Lane Center B3 WBL Lane Center B4 EBL Lane Center B WBL Lane Center B6 EBL Lane Center CPT1 EBL Lane Center CPT2 WBL Lane Center CPT3 EBL Lane Center CPT4 WBL Lane Center CPT EBL Lane Center CPT6 WBL Lane Center Responsive Resourceful Reliable Exhibit A

11 Swave velocity (ft/s) Testing Results, top of layer Swave velocity (ft/s) Frequency (Hz) Swave velocity model : Active and Passive Combined.rst Phase velocity (ft/s) Average Weighted Shear Wave Velocity (ft/s) 1 = 90 Seismic Site Classification = D 1. Average shear wave velocity based on native soils between 8 ft and 8 ft. 0 Dispersion curve : Active and Passive Combined.rst Project Mgr: Project No. PM Prepared by: WB Checked by: Scale: 73100L BS NA Emergency Bridge Package 6 Back Swamp Bridge PM /9/2016 SC 48 (Bluff Road), Richland County, SC Approved by: Date: 140 FIFTH STREET WEST NORTH CHARLESTON, SC PH: (843) Fax. (843) GEOPHYSICAL TESTING RESULTS MASW SHEAR WAVE VELOCITY EXHIBIT A6

12 Swave velocity (ft/s) Testing Results, top of layer Swave velocity (ft/s) Frequency (Hz) Swave velocity model : Passive and Active Combined.rst Phasevelocity (ft/s) Average Weighted Shear Wave Velocity (ft/s) 1 = 1231 Seismic Site Classification = C 1. Average shear wave velocity based on native soils between 8 ft and 8 ft. 0 Dispersion curve : Passive and Active Combined.rst Project Mgr: Project No. PM Prepared by: WB Checked by: Scale: 73100L BS NA Emergency Bridge Package 6 Cedar Creek Bridge PM /9/2016 SC 48 (Bluff Road), Richland County, SC Approved by: Date: 140 FIFTH STREET WEST NORTH CHARLESTON, SC PH: (843) Fax. (843) GEOPHYSICAL TESTING RESULTS MASW SHEAR WAVE VELOCITY EXHIBIT A7

13 Swave velocity (ft/s) Testing Results, top of layer Swave velocity (ft/s) Frequency (Hz) Swave velocity model : Passive and Active Combined.rst Phasevelocity(ft/s) Average Weighted Shear Wave Velocity (ft/s) 1 = 1217 Seismic Site Classification = C 1. Average shear wave velocity based on native soils between 8 ft and 8 ft. 0 Dispersion curve : Passive and Active Combined.rst Project Mgr: Project No. PM Prepared by: WB Checked by: Scale: 73100L BS NA Emergency Bridge Package 6 Dry Branch Bridge PM /9/2016 SC 48 (Bluff Road), Richland County, SC Approved by: Date: 140 FIFTH STREET WEST NORTH CHARLESTON, SC PH: (843) Fax. (843) GEOPHYSICAL TESTING RESULTS MASW SHEAR WAVE VELOCITY EXHIBIT A8

14 Geotechnical Data Report Emergency Bridge Package 6 Richland County, SC May 12, 2016 Terracon Project No L (Rev. 1) FIELD EXPLORATION DESCRIPTION Overview The testing locations were provided by the SCDOT and located in the field by Terracon by taking measurements from existing structures shown on the provided drawings. The borings were surveyed by Construction Support Services, LLC after testing and drilling was complete. The locations as shown in the Exploration Location Plan are shown to the scale indicated. A field log of each test location was prepared by our engineer. The final boring logs included with this report represent the engineer's description of the encountered conditions modified as necessary based on laboratory test results of the individual samples. Soil Test Borings (STB) All boring and sampling operations were conducted in general accordance with the following procedures: SCDOT Geotechnical Design Manual 20 ASTM D783, Standard Guide for Use of Direct Rotary Drilling with WaterBased Drilling Fluid for Geoenvironmental Exploration ASTM D186 Test Method for Penetration Test and SplitBarrel Sampling of Soils ASTM D4220 Standard Practices for Preserving and Transporting Soil Each boring was advanced using rotary wash drilling techniques. Five samples were collected in the upper feet. Below that depth, samples were obtained at foot intervals. Soil samples were obtained with a standard 1.4inch I.D., 2inch O.D., splitbarrel sampler, also known as a standard splitspoon. The sampler is advanced into the soil a total of 18 inches by striking the drill rod using a 140pound automatic hammer falling 30 inches. The number of blows required to advance the sampler for each of three, 6inch increments is recorded. The sum of the number of blows for the second and third increments is called the Standard Penetration Value, or Nvalue (N meas, blows per foot). The Nvalue, when properly evaluated, is an index to the soil strength. Soil Classification provides a general guide to the engineering properties of various soil types and enables the engineer to apply his experience to current situations. In our exploration, samples obtained during drilling operations are examined and visually classified by a geotechnical engineer using the procedures outlined in ASTM D2487 Standard Classification of Soils for Engineering Purposes (Unified Soil Classification System). Laboratory testing was also performed on select splitspoon samples to evaluate index properties for further classification. The soils are described according to color, texture, and relative density or consistency (based on standard penetration resistance). The designations shown on the logs are described on Exhibit A and Exhibit C2. Due to the drilling method (i.e. rotary wash), timeofdrilling water levels were not be recorded. The 24hour groundwater readings were collected from the borings. These are indicated on the Responsive Resourceful Reliable Exhibit A9

15 Geotechnical Data Report Emergency Bridge Package 6 Richland County, SC May 12, 2016 Terracon Project No L (Rev. 1) boring logs. At the conclusion of the work, the boreholes were backfilled with drill cuttings and capped with coldpatch asphalt. Cone Penetration Test Soundings (CPT) Cone Penetration Test soundings were conducted in general accordance with ASTM D778 Standard Test Method for Performing Electronic Friction Cone and Piezocone Penetration Testing of Soils. To facilitate CPT testing, the asphalt pavement at each location was predrilled exposing the underlying soils. Seismic Surface Wave Testing MultiChannel Analysis of Surface Waves (MASW testing) was performed to determine the shear wave velocity profile of the layered soil system. At the test location both MASW readings (active) and Microtremor Array Measurement (MAM) readings (passive) were recorded. The MASW test was conducted using the 24channel Geometrics Geode seismographs and 4.Hz geophones with a linear geometry at an interval of ft. Surface waves were generated by a 20pound sledgehammer striking a polyethylene plate at four locations. MAM testing was performed along the same survey line. MASW (Active) Testing MultiChannel Analysis of Surface Waves (MASW) is a seismic method that uses the dispersive characteristics of Rayleightype surface waves to determine the variation of the shearwave velocity of layered soils with depth. MAM (Passive) Testing Microtremor Array Measurement (MAM) for lower frequency surface waves (passive waves) arising from microtremors and/or urban (traffic) noise and recorded them using a linear or two dimensional (triangle, circle, semicircle, and shapes ) array of geophones (Zywicki and Rix, 1999; Lie et al., 2000). Multiple noise records are required for analysis. The data filters out the Rayleigh waves through a technique called spatial autocorrection (SPAC). This allows the development of a dispersion curve that is defined as the lower envelope of the measured energy peaks. MAM testing results in lower peak energy selections than the active testing described above. Responsive Resourceful Reliable Exhibit A9

16 SOIL DESCRIPTION TERMS Relative Density/Consistency Terms Relative Density 1 Consistency 2 Unconfined SPT Blow Descriptive Term Relative Density SPT Blow Count Descriptive Term Compression Count Strength (qu) (tsf) Very Loose 0 to 1% 4 and less Very Soft 0.2 and less 2 and less Loose 16 to 3% to Soft 0.26 to to 4 Medium Dense 36 to 6% 11 to 30 Firm 0.1 to 1.00 to 8 Dense 66 to 8% 31 to 0 Stiff 1.01 to to 1 Very Dense 86 to 0% 1 and more Very Stiff 2.01 to to 30 Hard 4.01 and more 31 and more Moisture Condition Descriptive Term Criteria Dry Absence of moisture, dusty, dry to the touch Moist Damp but no visible water Wet Visible free water, usually in coarsegrained soils below the water table Color Describe the sample color while sample is still moist. Angularity 1 Descriptive Term Angular Subangular Subrounded Rounded HCI Reaction 3 Descriptive Term None Reactive Weakly Reactive Strongly Reactive Cementation 3 Descriptive Term Weakly Cemented Moderately Cemented Strongly Cemented Criteria Particles have sharp edges and relatively plane sides with unpolished surfaces. Particles are similar to angular description but have rounded edges. Particles have nearly plane sides but have wellrounded corners and edges. Particles have smoothly curved sides and no edges. Criteria No visible reaction Some reaction, with bubbles forming slowly Violent reaction, with bubbles forming immediately Criteria Crumbles or breaks with handling or little finger pressure Crumbles or breaks with considerable finger pressure Will not crumble or break with finger pressure ParticleSize Range 1 Gravel Diameter, mm Sieve Size Sand Diameter, mm Sieve Size Fine 4.76 to 19.1 #4 to ¾ inch Fine to 0.42 #200 to #40 Coarse 19.1 to 76.2 ¾ inch to 3 inch Medium 0.42 to 2.00 #40 to # Coarse 4.00 to 4.76 # to #4 Primary Soil Type 1, 2 The primary soil type will be shown in all capital letters. USCS Soil Designation Indicate USCS soil designation as defined in ASTM D2487 and D2488 AASHTO Soil Designation Indicate AASHTO soil designation as defined in AASHTO M14 and ASTM D Applies to coarsegrained soils (major portion retained on No. 200 sieve) 2 Applies to finegrained soils (major portion passing No. 200 sieve) 3 Use as required Responsive Resourceful Reliable Exhibit A

17 Soil Test Log Project ID: P County: Richland Boring No.: B1 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/26/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/28/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION 0.0 Roadway Back Swamp Bridge ASPHALT (12 inches) Graphic Log No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) FILL Loose, moist, grayish brown, subrounded to subangular, weakly cemented, fine to medium Clayey SAND (SC) (A6) YR NMC=20.1, %#200= SS1 SS Firm to soft, moist, grayish brown, Sandy Lean CLAY (CL) (A6) YR /2.0 SS3 1 3 LL=28, PL=1, PI=13, NMC=23.2, %#200= SS Very soft, wet, grayish brown, Sandy Lean CLAY trace organics (CL) (A6) YR /2 9.0 SS WOH/18" ALLUVIUM Very soft, moist, gray, Sandy Lean CLAY trace organics (roots) (CL) (A6) YR 6/1 13. SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 17.0 COASTAL PLAIN Medium dense, wet, brown, subround to subangular, fine to coarse Poorly Graded SAND (SP) (A3) YR /3 Split Spoon Undisturbed Rock Core, NMC=13.3, %#200=4.0 SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 18. LEGEND HSA CFA DC SS6 SS7 WOH/18" Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

18 Soil Test Log Project ID: P County: Richland Boring No.: B1 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/26/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/28/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) Very loose, wet, white, subrounded to subangular, fine to medium Well Graded SAND with silt (SWSM) (A3) YR 8/1 23. SS SS9WOH/12" Loose, wet, white, subrounded to subangular, fine to coarse Well Graded SAND (SW) (A3) YR 8/1 33. SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 42.0 Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 38. LEGEND HSA CFA DC SS11 4 Hollow Stem Auger Continuous Flight Augers Driving Casing 3 2 DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

19 Soil Test Log Project ID: P County: Richland Boring No.: B1 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/26/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/28/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Medium dense, wet, brownish yellow, subrounded to subangular, fine to medium Silty SAND with clay seams (SM) (A24) YR 6/6 Graphic Log 43. No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) SS Hard, dry, gray, Lean CLAY (CL) (A6) YR LL=34, PL=22, PI=12, NMC= SS /" 0/" >> Very dense, moist, gray, fine Silty SAND with mica and silt seams (SM) (A24) YR 6/1 3. SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG Hard, moist, dark gray, Lean CLAY (CL) (A6) YR 4/1 Dense to very dense, wet, gray, subrounded to subangular, fine to medium Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 8. LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

20 Soil Test Log Project ID: P County: Richland Boring No.: B1 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/26/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/28/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Silty SAND with mica (SM) (A24) YR 4/1 Graphic Log 63. No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) SS NMC=17.3, %#200= SS SS /3" 0/3" >> 46.1 SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube LEGEND HSA CFA DC SS /" 0/" Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core >>

21 Soil Test Log Project ID: P County: Richland Boring No.: B1 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/26/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/28/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log No./Type SS20 1st 6" 23 2nd 6" 28 3rd 6" 36 N Value 64 PL MC LL FINES CONTENT (%) SS SS22 3 0/3" 0/3" >> 26.1 SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 0.0 Split Spoon Undisturbed Rock Core, 11/8" Boring Terminated at 0 Feet SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 98. LEGEND HSA CFA DC SS /4" 0/4" Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Rotary Wash Rock Core >>

22 Soil Test Log Project ID: P County: Richland Boring No.: B2 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/27/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/28/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION 0.0 Roadway Back Swamp Bridge ASPHALT (12 inches) Graphic Log No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) FILL Medium dense to loose, moist, grayish brown, subrounded to subangular, weakly cemented, fine to medium Clayey SAND with clay seams (SC) (A26) YR / SS SS SS SS ALLUVIUM Very soft, wet, gray, Sandy Lean CLAY (CL) (A76)YR 6/1 9.0 SS WOH/18" LL=4, PL=17, PI=28, NMC=32.8, %#200=9.4 SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG COASTAL PLAIN Loose, wet, dark brown, subrounded to subangular, weakly cemented, fine to medium Clayey SAND (SC) (A26) YR 3/3 Loose, wet, brown, subrounded to subangular, fine to coarse Poorly Graded SAND (SP) (A3) YR 4/3 Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube LEGEND HSA CFA DC SS6 SS Hollow Stem Auger Continuous Flight Augers Driving Casing 8 DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

23 Soil Test Log Project ID: P County: Richland Boring No.: B2 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/27/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/28/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) Stiff, moist, white, Sandy SILT (ML) (A4) YR NMC=21.6, %#200= SS SS Medium dense, wet, white, subrounded to subangular, fine Silty SAND (SM) (A24) YR 8/1 33. SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 42.0 Split Spoon Undisturbed Rock Core, NMC=20., %#200=20.0 SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 38. LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

24 Soil Test Log Project ID: P County: Richland Boring No.: B2 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/27/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/28/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Very stiff, moist, gray, Sandy Lean CLAY (CL) (A6) YR 6/1 Graphic Log No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) SS Medium dense, wet, gray, subrounded to subangular, fine to medium Silty SAND (SM) (A24) YR 6/1 48. SS SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 7.0 Hard, moist, dark gray, Lean CLAY (CL) (A6) YR 4/1 Split Spoon Undisturbed Rock Core, LL=31, PL=22, PI=9, NMC=19.3 SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 8. LEGEND HSA CFA DC SS /4" 0/4" Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core >>

25 Soil Test Log Project ID: P County: Richland Boring No.: B2 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/27/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/28/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log 63. No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) SS /4" 0/4" >> Very dense to dense, wet, gray, subangular, fine to medium Silty SAND (SM) (A24) YR 6/1 68. SS /" 0/" >> SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 77.0 Hard, dry, dark gray, Lean CLAY (CL) (A6) YR 4/1 Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

26 Soil Test Log Project ID: P County: Richland Boring No.: B2 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/27/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/28/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log No./Type SS20 1st 6" 24 2nd 6" 36 3rd 6" 40 N Value 76 PL MC LL FINES CONTENT (%) NMC=33., %#200= SS SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 0.0 Split Spoon Undisturbed Rock Core, 11/8" Boring Terminated at 0 Feet SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 98. LEGEND HSA CFA DC SS /" 0/" Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Rotary Wash Rock Core >>

27 Soil Test Log Project ID: P County: Richland Boring No.: B3 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/28/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/29/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 11 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION 0.0 Roadway Cedar Creek Bridge 0.3 ASPHALT (4 inches) Graphic Log 0.3 No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) FILL Loose, moist, brown, subrounded to subangular, weakly cemented, fine to medium Clayey SAND (SC) (A26) YR /3 2.0 SS1 SS LL=26, PL=14, PI=12, NMC=13., %#200= SS SS Very loose, wet, grayish brown, subrounded to subangular, fine to medium Clayey SAND (SC) (A26) YR /2 8.0 SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG COASTAL PLAIN Medium dense, wet, grayish brown, subrounded to subangular, fine to coarse Poorly Graded SAND (SP) (A3) YR /2 Medium dense, wet, gray, subrounded to subangular, fine to coarse Silty SAND (SM) (A24) YR 6/1 Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube LEGEND HSA CFA DC SS6 SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

28 Soil Test Log Project ID: P County: Richland Boring No.: B3 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/28/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/29/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 11 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) Very loose, wet, white, subrounded to subangular, fine to medium Silty SAND (SM) (A24) YR 8/1 NMC=26.1, %#200=12.9 SS Medium dense, wet, white, subrounded to subangular, fine Silty SAND micaceous (SM) (A24) YR 8/1 28. SS SS 7 17 SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 37.0 Medium dense, wet, brown, subrounded to subangular, fine to medium Silty SAND (SM) (A24) YR /3 Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 38. LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

29 Soil Test Log Project ID: P County: Richland Boring No.: B3 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/28/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/29/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 11 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) SS Medium dense, wet, white, subrounded to subangular, fine Silty SAND with clay seams (SM) (A24) YR 8/1 48. SS SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 7.0 Hard, dry, dark brown, SILT (ML) (A7) YR 3/3 Split Spoon Undisturbed Rock Core, LL=4, PL=27, PI=18, NMC=24.4 SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 8. LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

30 Soil Test Log Project ID: P County: Richland Boring No.: B3 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/28/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/29/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 11 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log 63. No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) SS Very stiff, moist, brownish gray, Sandy Lean CLAY (CL) (A6) YR /2 68. SS Medium dense to dense, wet, brown, subrounded to subangular, fine to medium Silty SAND (SM) (A24) YR /3 73. SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG Split Spoon Undisturbed Rock Core, NMC=16.6, %#200=24.1 SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

31 Soil Test Log Project ID: P County: Richland Boring No.: B3 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: R. Sarkar Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/28/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: 4/29/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 11 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log No./Type SS20 1st 6" 12 2nd 6" 16 3rd 6" 21 N Value 37 PL MC LL FINES CONTENT (%) Hard, dry, dark gray, Lean CLAY (CL) (A6) YR NMC=27., %#200= SS Dense, wet, gray, subrounded to subangular, fine to medium Silty SAND with clay seams (SM) (A24) YR 6/1 93. SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG Hard, dry, gray, Sandy SILT with clay seams and mica (ML) (A4) YR 6/1 Split Spoon Undisturbed Rock Core, 11/8" Boring Terminated at 0 Feet SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 98. LEGEND HSA CFA DC SS /" 0/" Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Rotary Wash Rock Core >>

32 Soil Test Log Project ID: P County: Richland Boring No.: B4 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/29/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /2/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION 0.0 Roadway Cedar Creek Bridge Asphalt (9 inches) 0.8 FILL Medium dense, dry, light yellowish brown, subangular, weakly cemented, fine to medium Silty SAND (SM) (A24) YR 6/4 Graphic Log 1.0 No./Type SS1 1st 6" 4 2nd 6" 6 3rd 6" 7 N Value 13 PL MC LL FINES CONTENT (%) SS Medium dense, dry, light yellowish brown, subangular, weakly cemented, fine to medium Silty SAND with gravel (SM) (A24) YR 6/4 Very loose, moist, light yellowish brown, subangular, weakly cemented, fine to medium Silty SAND (SM) (A24) YR 6/ SS3 SS ALLUVIUM Very loose, moist, dark yellowish brown, subangular, weakly cemented, fine to medium Clayey SAND with gravel (SC) (A26) YR 4/6 9.0 SS WOH/18" 0 LL=3, PL=19, PI=16, NMC=23.8, %#200=30.2 SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 17.0 COASTAL PLAIN Medium dense, moist, dark yellowish brown, subangular, weakly cemented, fine to medium Silty SAND (SM) (A24) YR NMC=19.8, %#200=16.1 Medium dense, moist, light gray, subangular, weakly cemented, fine to medium Silty SAND with gravel (SM) (A24) YR 2/7 Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube LEGEND HSA CFA DC SS6 SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

33 Soil Test Log Project ID: P County: Richland Boring No.: B4 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/29/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /2/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) Medium dense, dry, light gray, subrounded, weakly cemented, fine Poorly Graded SAND with silt (SPSM) (A3) YR 7/2 23. SS SS NMC=22.6, %#200= SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 42.0 Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 38. LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

34 Soil Test Log Project ID: P County: Richland Boring No.: B4 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/29/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /2/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Dense, moist, dark grayish brown, subangular, weakly cemented, fine to coarse Silty SAND (SM) (A24) YR 4/2 Graphic Log 43. No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) SS Hard, moist, dark grayish brown, Lean CLAY (CL) (A6) YR NMC=28.9, %#200= SS SS /1" 0/1" >> 77.1 SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG Hard, moist, dark yellowish brown, Sandy lean CLAY (CL) (A6) YR 4/4 Hard, moist, light yellowish brown, Sandy CLAY with organics (CL) (A6) YR 6/4 Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 8. LEGEND HSA CFA DC SS /4" 0/4" Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core >>

35 Soil Test Log Project ID: P County: Richland Boring No.: B4 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/29/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /2/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log 63. No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) SS Hard, moist, light yellowish brown, Sandy lean CLAY (CL) (A7) YR 6/4 68. SS LL=4, PL=26, PI=19, NMC= SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

36 Soil Test Log Project ID: P County: Richland Boring No.: B4 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: 4/29/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /2/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log No./Type SS20 1st 6" 13 2nd 6" 19 3rd 6" 24 N Value 43 PL MC LL FINES CONTENT (%) SS SS /4" 0/4" >> 37.1 SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG Hard, moist, very pale brown, Sandy lean CLAY with gravel (CL) (A6) YR 8/4 Split Spoon Undisturbed Rock Core, 11/8" Boring Terminated at 0 Feet SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 98. LEGEND HSA CFA DC SS /2" 0/2" Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Rotary Wash Rock Core >>

37 Soil Test Log Project ID: P County: Richland Boring No.: B Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: /2/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /3/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR ft SPT N VALUE N Elevation MATERIAL DESCRIPTION 0.0 Roadway Dry Branch Bridge Asphalt (9 inches) 0.8 FILL Medium dense, dry, dark yellowish brown, subangular, weakly cemented, fine to medium Silty SAND (SM) (A24) YR 4/6 Graphic Log 1.0 No./Type SS1 1st 6" 2nd 6" 9 3rd 6" 6 N Value 1 PL MC LL FINES CONTENT (%) Loose, dry, grayish brown, subangular, weakly cemented, fine to medium Silty SAND with crushed aggregate (SM) (A24) YR /2 Loose to very loose, dry, grayish brown, subangular, weakly cemented, fine to medium Silty SAND (SM) (A24) YR / SS2 SS NMC=13.7, %#200= SS NMC=37.1, %#200= SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 12.0 COASTAL PLAIN Medium dense, moist, yellowish brown, subangular, weakly cemented, fine to medium Silty SAND (SM) (A24) YR /4 Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube LEGEND HSA CFA DC SS6 SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

38 Soil Test Log Project ID: P County: Richland Boring No.: B Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: /2/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /3/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) Loose, wet, white, subangular, moderately cemented, fine to coarse Clayey SAND with gravel (SC) (A26) 9.2/N LL=43, PL=19, PI=24, NMC=23.3 SS Very loose, wet, white, subangular, weakly cemented, fine to coarse Poorly Graded SAND with silt (SPSM) (A3) 9./N NMC=26.3, %#200=.7 SS Dense, moist, white, subrounded, weakly cemented, fine Silty SAND (SM) (A24) 9./N 33. SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG Very loose, wet, white, subrounded, weakly cemented, fine Silty SAND (SM) (A24) 9./N Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 38. LEGEND HSA CFA DC SS11 3 Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

39 Soil Test Log Project ID: P County: Richland Boring No.: B Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: /2/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /3/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log Medium dense to dense, moist, dark yellowish brown, subrounded, weakly cemented, fine Silty SAND (SM) (A24) YR 4/4 43. No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) SS SS SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 63.0 Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 8. LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

40 Soil Test Log Project ID: P County: Richland Boring No.: B Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: /2/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /3/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Medium dense, moist, dark yellowish brown, subrounded, weakly cemented, fine to medium Silty SAND (SM) (A24) YR 4/4 Graphic Log 63. No./Type SS16 1st 6" 9 2nd 6" 12 3rd 6" 1 N Value 27 PL MC LL FINES CONTENT (%) NMC=28.0, %#200= SS SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

41 Soil Test Log Project ID: P County: Richland Boring No.: B Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: WBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: /2/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /3/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log No./Type SS20 1st 6" 14 2nd 6" 14 3rd 6" 14 N Value 28 PL MC LL FINES CONTENT (%) SS Dense, moist, very dark brown, subrounded, moderately cemented, fine to medium Clayey SAND with organics (SC) (A26) YR 2/2 93. SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG Medium dense, moist, dark yellowish brown, subrounded, weakly cemented, fine to medium Silty SAND (SM) (A24) YR 4/4 Split Spoon Undisturbed Rock Core, 11/8" Boring Terminated at 0 Feet SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 98. LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Rotary Wash Rock Core

42 Soil Test Log Project ID: P County: Richland Boring No.: B6 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: /3/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /4/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION 0.0 Roadway Dry Branch Bridge Asphalt (12 inches) Graphic Log No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) FILL Medium dense to loose, dry, dark yellowish brown, subrounded, weakly cemented, fine to medium Clayey SAND (SC) (A26) YR 4/ SS SS Very loose to loose, dry, dark yellowish brown, subrounded, weakly cemented, fine to medium Clayey SAND (SC) (A26) YR 4/ SS SS ALLUVIUM Very loose, wet, brownish yellow, subrounded, weakly cemented, fine to medium Clayey SAND with organics (SC) (A26) YR 6/6 9.0 SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG LL=1, PL=12, PI=3, NMC=1.8 COASTAL PLAIN Medium dense to loose, moist, dark yellowish brown, subrounded, weakly cemented, fine to medium Silty SAND (SM) (A24) YR 4/2 Split Spoon Undisturbed Rock Core, NMC=16.6, %#200=20.0 SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube LEGEND HSA CFA DC SS6 SS Hollow Stem Auger Continuous Flight Augers Driving Casing 8 DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

43 Soil Test Log Project ID: P County: Richland Boring No.: B6 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: /3/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /4/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) Loose, moist, dark grayish brown, subrounded, weakly cemented, fine to medium Silty SAND with gravel (SM) (A24) YR 4/2 23. NMC=20.1, %#200=17.8 SS Loose to medium dense, moist, dark grayish brown, subrounded, weakly cemented, fine to medium Silty SAND (SM) (A24) YR 4/2 28. SS SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 42.0 Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 38. LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

44 Soil Test Log Project ID: P County: Richland Boring No.: B6 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: /3/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /4/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Soft, moist, grayish brown, Sandy SILT (ML) (A6) YR /2 Graphic Log No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) LL=36, PL=2, PI=11, NMC=31.6, %#200= SS Dense to medium dense, wet, light brownish gray, subrounded, weakly cemented, fine to medium Silty SAND (SM) (A24) YR 6/2 48. SS SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 8. LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

45 Soil Test Log Project ID: P County: Richland Boring No.: B6 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: /3/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /4/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log 63. No./Type 1st 6" 2nd 6" 3rd 6" N Value PL MC LL FINES CONTENT (%) SS Dense to medium dense, moist, brownish yellow, subrounded, weakly cemented, fine to medium Silty SAND (SM) (A24) YR 6/6 68. NMC=28.9, %#200=16.3 SS SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG Medium dense, moist, dark yellowish brown, subrounded, weakly cemented, fine to medium Clayey SAND (SC) (A26) YR 4/4 Dense, wet, light yellowish brown, subrounded, weakly cemented, fine to medium Silty SAND (SM) (A24) YR 6/4 Split Spoon Undisturbed Rock Core, 11/8" SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Continued Next Page Rotary Wash Rock Core

46 Soil Test Log Project ID: P County: Richland Boring No.: B6 Site Description: Emergency Bridge Package 6 Route: SC 48 Eng./Geo.: J. Fredendall Boring Location: EBL Offset: Lane Ctr Alignment: Existing Elev.: ft Latitude: Longitude: Date Started: /3/2016 Total : 0 ft Soil : 0 ft Core : 0 ft Date Completed: /4/2016 Bore Hole Diameter (in): 2.94 r Configuration Liner Required: Y N Liner Used: Y Drill Machine: CME0X Drill Method: RW Hammer Type: Automatic Energy Ratio: 74.2% Core Size: N.A. Driller: A. Large Groundwater: TOB N.A. 24HR 9 ft SPT N VALUE N Elevation MATERIAL DESCRIPTION Graphic Log No./Type SS20 1st 6" 12 2nd 6" 1 3rd 6" 20 N Value 3 PL MC LL FINES CONTENT (%) Very dense, moist, black, subrounded, moderately cemented, fine to medium Clayey SAND with organics (SC) (A26) YR 2/1 88. SS /" 0/" >> Medium dense to dense, moist, dark yellowish brown, subrounded, weakly cemented, fine to medium Silty SAND (SM) (A24) YR 4/4 93. SS SC_DOT 73100L.GPJ SCDOT DATA TEMPLATE_12_30_2014.GDT /12/ SS UD AWG 0.0 Split Spoon Undisturbed Rock Core, 11/8" Boring Terminated at 0 Feet SAMPLER TYPE NQ CU CT Rock Core, 17/8" Cuttings Continuous Tube 98. LEGEND HSA CFA DC SS Hollow Stem Auger Continuous Flight Augers Driving Casing DRILLING METHOD RW RC Rotary Wash Rock Core

47 THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. CPT REPORT EN100L (COLUMBIA SCDOT EMERGENCY BRIDGE).GPJ TERRACON201.GDT /12/ SCDOT Project # P See Exhibit A3 for description of field procedures. See Appendix C for explanation of symbols and abbreviations. WATER LEVEL OBSERVATION 9 ft measured water depth (used in normalizations and correlations; see Appendix C) Probe no. 426 with net area ratio of 0.83 U2 pore pressure transducer location Manufactured by Geotech A.B.; calibrated 12/7/201 Tip and sleeve areas of cm 2 and 10 cm 2 Ring friction reducer with O.D. of 1.87 in CPT LOG NO. CPT1 21 Clemson Rd Columbia, SC Dead weight of rig used as reaction force. CPT sensor calibration reports available upon request. CPT Started: /2/2016 Rig: Pagani TG73200 Project No.: 73100L 1 Sensitive, fine grained 2 Organic soils clay CPT Completed: /2/2016 Operator: JB Exhibit: A17 Page 1 of 1 PROJECT: Emergency Bridge Package 6 CLIENT: SCDOT TEST LOCATION: See Exhibit A2 Columbia, SC Surface Elev.: ft SITE: SC 48 (Bluff Road) Richland County, South Carolina Latitude: Longitude: Station: EBL Offset: Lane Ctr Tip Resistance, q t (tsf) CPT Refused at 44.8 Feet Sleeve Friction, f s (tsf) Friction Ratio, F r (%) >> Hydrostatic Pressure Pore Pressure, u 2 (tsf) Material Description Normalized CPT Soil Behavior Type Clay silty clay to clay 4 Silt mixtures clayey silt to silty clay Sand mixtures silty sand to sandy silt 6 Sands clean sand to silty sand 7 Gravelly sand to dense sand 8 Very stiff sand to clayey sand 9 Very stiff fine grained Elev

48 THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. CPT REPORT EN100L (COLUMBIA SCDOT EMERGENCY BRIDGE).GPJ TERRACON201.GDT /12/ SCDOT Project # P See Exhibit A3 for description of field procedures. See Appendix C for explanation of symbols and abbreviations. WATER LEVEL OBSERVATION 9 ft measured water depth (used in normalizations and correlations; see Appendix C) Probe no. 426 with net area ratio of 0.83 U2 pore pressure transducer location Manufactured by Geotech A.B.; calibrated 12/7/201 Tip and sleeve areas of cm 2 and 10 cm 2 Ring friction reducer with O.D. of 1.87 in CPT LOG NO. CPT2 21 Clemson Rd Columbia, SC Dead weight of rig used as reaction force. CPT sensor calibration reports available upon request. CPT Started: /2/2016 Rig: Pagani TG73200 Project No.: 73100L 1 Sensitive, fine grained 2 Organic soils clay CPT Completed: /2/2016 Operator: JB Exhibit: A18 Page 1 of 1 PROJECT: Emergency Bridge Package 6 CLIENT: SCDOT TEST LOCATION: See Exhibit A2 Columbia, SC Surface Elev.: ft SITE: SC 48 (Bluff Road) Richland County, South Carolina Latitude: Longitude: Station: WBL Offset: Lane Ctr Tip Resistance, q t (tsf) CPT Refused at 39.8 Feet Sleeve Friction, f s (tsf) >> >> >> Friction Ratio, F r (%) >> >> >> >> >> >> Hydrostatic Pressure Pore Pressure, u 2 (tsf) Material Description Normalized CPT Soil Behavior Type Clay silty clay to clay 4 Silt mixtures clayey silt to silty clay Sand mixtures silty sand to sandy silt 6 Sands clean sand to silty sand 7 Gravelly sand to dense sand 8 Very stiff sand to clayey sand 9 Very stiff fine grained Elev

49 THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. CPT REPORT EN100L (COLUMBIA SCDOT EMERGENCY BRIDGE).GPJ TERRACON201.GDT /12/ SCDOT Project # P See Exhibit A3 for description of field procedures. See Appendix C for explanation of symbols and abbreviations. WATER LEVEL OBSERVATION 11 ft measured water depth (used in normalizations and correlations; see Appendix C) Probe no. 426 with net area ratio of 0.83 U2 pore pressure transducer location Manufactured by Geotech A.B.; calibrated 12/7/201 Tip and sleeve areas of cm 2 and 10 cm 2 Ring friction reducer with O.D. of 1.87 in CPT LOG NO. CPT3 21 Clemson Rd Columbia, SC Dead weight of rig used as reaction force. CPT sensor calibration reports available upon request. CPT Started: /3/2016 Rig: Pagani TG73200 Project No.: 73100L 1 Sensitive, fine grained 2 Organic soils clay CPT Completed: /3/2016 Operator: JB Exhibit: A19 Page 1 of 1 PROJECT: Emergency Bridge Package 6 CLIENT: SCDOT TEST LOCATION: See Exhibit A3 Columbia, SC Surface Elev.: ft SITE: SC 48 (Bluff Road) Richland County, South Carolina Latitude: Longitude: Station: EBL Offset: Lane Ctr Tip Resistance, q t (tsf) CPT Refused at 19.3 Feet >> Sleeve Friction, f s (tsf) Friction Ratio, F r (%) Hydrostatic Pressure Pore Pressure, u 2 (tsf) Material Description Normalized CPT Soil Behavior Type Clay silty clay to clay 4 Silt mixtures clayey silt to silty clay Sand mixtures silty sand to sandy silt 6 Sands clean sand to silty sand 7 Gravelly sand to dense sand 8 Very stiff sand to clayey sand 9 Very stiff fine grained Elev

50 THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. CPT REPORT EN100L (COLUMBIA SCDOT EMERGENCY BRIDGE).GPJ TERRACON201.GDT /12/ SCDOT Project # P See Exhibit A3 for description of field procedures. See Appendix C for explanation of symbols and abbreviations. WATER LEVEL OBSERVATION 9 ft measured water depth (used in normalizations and correlations; see Appendix C) Probe no. 426 with net area ratio of 0.83 U2 pore pressure transducer location Manufactured by Geotech A.B.; calibrated 12/7/201 Tip and sleeve areas of cm 2 and 10 cm 2 Ring friction reducer with O.D. of 1.87 in CPT LOG NO. CPT4 21 Clemson Rd Columbia, SC Dead weight of rig used as reaction force. CPT sensor calibration reports available upon request. CPT Started: /3/2016 Rig: Pagani TG73200 Project No.: 73100L 1 Sensitive, fine grained 2 Organic soils clay CPT Completed: /3/2016 Operator: JB Exhibit: A20 Page 1 of 1 PROJECT: Emergency Bridge Package 6 CLIENT: SCDOT TEST LOCATION: See Exhibit A3 Columbia, SC Surface Elev.: ft SITE: SC 48 (Bluff Road) Richland County, South Carolina Latitude: Longitude: Station: WBL Offset: Lane Ctr Tip Resistance, q t (tsf) CPT Refused at 20.3 Feet Sleeve Friction, f s (tsf) Friction Ratio, F r (%) Hydrostatic Pressure Pore Pressure, u 2 (tsf) Material Description Normalized CPT Soil Behavior Type Clay silty clay to clay 4 Silt mixtures clayey silt to silty clay Sand mixtures silty sand to sandy silt 6 Sands clean sand to silty sand 7 Gravelly sand to dense sand 8 Very stiff sand to clayey sand 9 Very stiff fine grained Elev

51 THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. CPT REPORT EN100L (COLUMBIA SCDOT EMERGENCY BRIDGE).GPJ TERRACON201.GDT /12/ SCDOT Project # P See Exhibit A3 for description of field procedures. See Appendix C for explanation of symbols and abbreviations. WATER LEVEL OBSERVATION ft measured water depth (used in normalizations and correlations; see Appendix C) Probe no. 426 with net area ratio of 0.83 U2 pore pressure transducer location Manufactured by Geotech A.B.; calibrated 12/7/201 Tip and sleeve areas of cm 2 and 10 cm 2 Ring friction reducer with O.D. of 1.87 in CPT LOG NO. CPT 21 Clemson Rd Columbia, SC Dead weight of rig used as reaction force. CPT sensor calibration reports available upon request. CPT Started: /3/2016 Rig: Pagani TG73200 Project No.: 73100L 1 Sensitive, fine grained 2 Organic soils clay CPT Completed: /3/2016 Operator: JB Exhibit: A21 Page 1 of 1 PROJECT: Emergency Bridge Package 6 CLIENT: SCDOT TEST LOCATION: See Exhibit A4 Columbia, SC Surface Elev.: ft SITE: SC 48 (Bluff Road) Richland County, South Carolina Latitude: Longitude: Station: EBL Offset: Lane Ctr Tip Resistance, q t (tsf) CPT Refused at 33.3 Feet Sleeve Friction, f s (tsf) Friction Ratio, F r (%) Hydrostatic Pressure Pore Pressure, u 2 (tsf) Material Description Normalized CPT Soil Behavior Type Clay silty clay to clay 4 Silt mixtures clayey silt to silty clay Sand mixtures silty sand to sandy silt 6 Sands clean sand to silty sand 7 Gravelly sand to dense sand 8 Very stiff sand to clayey sand 9 Very stiff fine grained Elev

52 THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. CPT REPORT EN100L (COLUMBIA SCDOT EMERGENCY BRIDGE).GPJ TERRACON201.GDT /12/ SCDOT Project # P See Exhibit A3 for description of field procedures. See Appendix C for explanation of symbols and abbreviations. WATER LEVEL OBSERVATION 9 ft estimated water depth (used in normalizations and correlations; see Appendix C) Probe no. 426 with net area ratio of 0.83 U2 pore pressure transducer location Manufactured by Geotech A.B.; calibrated 12/7/201 Tip and sleeve areas of cm 2 and 10 cm 2 Ring friction reducer with O.D. of 1.87 in CPT LOG NO. CPT6 21 Clemson Rd Columbia, SC Dead weight of rig used as reaction force. CPT sensor calibration reports available upon request. CPT Started: /3/2016 Rig: Pagani TG73200 Project No.: 73100L 1 Sensitive, fine grained 2 Organic soils clay CPT Completed: /3/2016 Operator: JB Exhibit: A22 Page 1 of 1 PROJECT: Emergency Bridge Package 6 CLIENT: SCDOT TEST LOCATION: See Exhibit A4 Columbia, SC Surface Elev.: ft SITE: SC 48 (Bluff Road) Richland County, South Carolina Latitude: Longitude: Station: WBL Offset: Lane Ctr Tip Resistance, q t (tsf) CPT Refused at 32 Feet Sleeve Friction, f s (tsf) Friction Ratio, F r (%) Hydrostatic Pressure Pore Pressure, u 2 (tsf) Material Description Normalized CPT Soil Behavior Type Clay silty clay to clay 4 Silt mixtures clayey silt to silty clay Sand mixtures silty sand to sandy silt 6 Sands clean sand to silty sand 7 Gravelly sand to dense sand 8 Very stiff sand to clayey sand 9 Very stiff fine grained Elev

53 THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. CPT CORRELATIVE PARAMETERS REPORT EN100L (COLUMBIA SCDOT EMERGENCY BRIDGE).GPJ TERRACON20 PROJECT: Emergency Bridge Package 6 SITE: SC 48 (Bluff Road) Richland County, South Carolina N 60 Value CPT Refused at 44.8 Feet WATER LEVEL OBSERVATION 9 ft measured water depth (used in normalizations and correlations; see Appendix C) CPT CORRELATIVE PARAMETER LOG NO. CPT1 Page 1 of 1 SEE CPT LOG NO. CPT1 FOR DETAILED TEST RESULTS Effective Friction Angle (degrees) (1) (2) Notes: Probe no. 426 with net area ratio of 0.83 Manufactured by Geotech A.B.; calibrated 12/7/201 Tip and sleeve areas of cm 2 and 10 cm 2 Ring friction reducer with O.D. of 1.87 in CLIENT: SCDOT Columbia, SC Undrained Shear Strength, S u Nkt = 14 (tsf) TEST LOCATION: CPT Completed: /2/2016 Operator: JB Station: EBL Offset: Lane Ctr Tip resistance, sleeve resistance, porewater pressure, and tilt angle are measured. Other parameters presented are derived from interpretations of the measured data, based upon published correlations, but do not necessarily represent actual values that would be derived from direct testing. Appendix C provides the formulas used for these correlations and presents estimates of the relative reliability associated with the correlated parameters. 21 Clemson Rd Columbia, SC OCR (1) (2) CPT Started: /2/2016 Rig: Pagani TG73200 >> >> Project No.: 73100L See Exhibit A2 Surface Elev.: ft Latitude: Longitude: Elastic Modulus, E s (tsf) (3) (4) Exhibit: A23 Material Description Normalized CPT Soil Behavior Type Elev

54 THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. CPT CORRELATIVE PARAMETERS REPORT EN100L (COLUMBIA SCDOT EMERGENCY BRIDGE).GPJ TERRACON20 PROJECT: Emergency Bridge Package 6 SITE: SC 48 (Bluff Road) Richland County, South Carolina N 60 Value CPT Refused at 39.8 Feet WATER LEVEL OBSERVATION 9 ft measured water depth (used in normalizations and correlations; see Appendix C) CPT CORRELATIVE PARAMETER LOG NO. CPT2 Page 1 of 1 SEE CPT LOG NO. CPT2 FOR DETAILED TEST RESULTS Effective Friction Angle (degrees) (1) (2) Notes: Probe no. 426 with net area ratio of 0.83 Manufactured by Geotech A.B.; calibrated 12/7/201 Tip and sleeve areas of cm 2 and 10 cm 2 Ring friction reducer with O.D. of 1.87 in CLIENT: SCDOT Columbia, SC Undrained Shear Strength, S u Nkt = 14 (tsf) TEST LOCATION: CPT Completed: /2/2016 Operator: JB Station: WBL Offset: Lane Ctr 4 7 Tip resistance, sleeve resistance, porewater pressure, and tilt angle are measured. Other parameters presented are derived from interpretations of the measured data, based upon published correlations, but do not necessarily represent actual values that would be derived from direct testing. Appendix C provides the formulas used for these correlations and presents estimates of the relative reliability associated with the correlated parameters. 21 Clemson Rd Columbia, SC OCR (1) (2) CPT Started: /2/2016 Rig: Pagani TG73200 >> >> >> Project No.: 73100L See Exhibit A2 Surface Elev.: ft Latitude: Longitude: Elastic Modulus, E s (tsf) (3) (4) Exhibit: A24 Material Description Normalized CPT Soil Behavior Type Elev

55 THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. CPT CORRELATIVE PARAMETERS REPORT EN100L (COLUMBIA SCDOT EMERGENCY BRIDGE).GPJ TERRACON20 PROJECT: Emergency Bridge Package 6 SITE: SC 48 (Bluff Road) Richland County, South Carolina N 60 Value CPT Refused at 19.3 Feet WATER LEVEL OBSERVATION 11 ft measured water depth (used in normalizations and correlations; see Appendix C) CPT CORRELATIVE PARAMETER LOG NO. CPT3 Page 1 of 1 SEE CPT LOG NO. CPT3 FOR DETAILED TEST RESULTS Effective Friction Angle (degrees) (1) (2) Notes: Probe no. 426 with net area ratio of 0.83 Manufactured by Geotech A.B.; calibrated 12/7/201 Tip and sleeve areas of cm 2 and 10 cm 2 Ring friction reducer with O.D. of 1.87 in CLIENT: SCDOT Columbia, SC Undrained Shear Strength, S u Nkt = 14 (tsf) TEST LOCATION: CPT Completed: /3/2016 Operator: JB Station: EBL Offset: Lane Ctr Tip resistance, sleeve resistance, porewater pressure, and tilt angle are measured. Other parameters presented are derived from interpretations of the measured data, based upon published correlations, but do not necessarily represent actual values that would be derived from direct testing. Appendix C provides the formulas used for these correlations and presents estimates of the relative reliability associated with the correlated parameters. 21 Clemson Rd Columbia, SC OCR (1) (2) CPT Started: /3/2016 Rig: Pagani TG73200 >> >> Project No.: 73100L See Exhibit A3 Surface Elev.: ft Latitude: Longitude: Elastic Modulus, E s (tsf) (3) (4) Exhibit: A2 Material Description Normalized CPT Soil Behavior Type Elev

56 THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. CPT CORRELATIVE PARAMETERS REPORT EN100L (COLUMBIA SCDOT EMERGENCY BRIDGE).GPJ TERRACON20 PROJECT: Emergency Bridge Package 6 SITE: SC 48 (Bluff Road) Richland County, South Carolina N 60 Value CPT Refused at 20.3 Feet WATER LEVEL OBSERVATION 9 ft measured water depth (used in normalizations and correlations; see Appendix C) CPT CORRELATIVE PARAMETER LOG NO. CPT4 Page 1 of 1 SEE CPT LOG NO. CPT4 FOR DETAILED TEST RESULTS Effective Friction Angle (degrees) (1) (2) Notes: Probe no. 426 with net area ratio of 0.83 Manufactured by Geotech A.B.; calibrated 12/7/201 Tip and sleeve areas of cm 2 and 10 cm 2 Ring friction reducer with O.D. of 1.87 in CLIENT: SCDOT Columbia, SC Undrained Shear Strength, S u Nkt = 14 (tsf) TEST LOCATION: CPT Completed: /3/2016 Operator: JB Station: WBL Offset: Lane Ctr Tip resistance, sleeve resistance, porewater pressure, and tilt angle are measured. Other parameters presented are derived from interpretations of the measured data, based upon published correlations, but do not necessarily represent actual values that would be derived from direct testing. Appendix C provides the formulas used for these correlations and presents estimates of the relative reliability associated with the correlated parameters. 21 Clemson Rd Columbia, SC OCR (1) (2) CPT Started: /3/2016 Rig: Pagani TG73200 >> Project No.: 73100L See Exhibit A3 Surface Elev.: ft Latitude: Longitude: Elastic Modulus, E s (tsf) (3) (4) Exhibit: A26 Material Description Normalized CPT Soil Behavior Type Elev

57 THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. CPT CORRELATIVE PARAMETERS REPORT EN100L (COLUMBIA SCDOT EMERGENCY BRIDGE).GPJ TERRACON20 PROJECT: Emergency Bridge Package 6 SITE: SC 48 (Bluff Road) Richland County, South Carolina N 60 Value CPT Refused at 33.3 Feet WATER LEVEL OBSERVATION ft measured water depth (used in normalizations and correlations; see Appendix C) CPT CORRELATIVE PARAMETER LOG NO. CPT Page 1 of 1 SEE CPT LOG NO. CPT FOR DETAILED TEST RESULTS Effective Friction Angle (degrees) (1) (2) Notes: Probe no. 426 with net area ratio of 0.83 Manufactured by Geotech A.B.; calibrated 12/7/201 Tip and sleeve areas of cm 2 and 10 cm 2 Ring friction reducer with O.D. of 1.87 in CLIENT: SCDOT Columbia, SC Undrained Shear Strength, S u Nkt = 14 (tsf) TEST LOCATION: CPT Completed: /3/2016 Operator: JB Station: EBL Offset: Lane Ctr Tip resistance, sleeve resistance, porewater pressure, and tilt angle are measured. Other parameters presented are derived from interpretations of the measured data, based upon published correlations, but do not necessarily represent actual values that would be derived from direct testing. Appendix C provides the formulas used for these correlations and presents estimates of the relative reliability associated with the correlated parameters. 21 Clemson Rd Columbia, SC OCR (1) (2) CPT Started: /3/2016 Rig: Pagani TG73200 >> >> Project No.: 73100L See Exhibit A4 Surface Elev.: ft Latitude: Longitude: Elastic Modulus, E s (tsf) (3) (4) Exhibit: A27 Material Description Normalized CPT Soil Behavior Type Elev

58 THIS BORING LOG IS NOT VALID IF SEPARATED FROM ORIGINAL REPORT. CPT CORRELATIVE PARAMETERS REPORT EN100L (COLUMBIA SCDOT EMERGENCY BRIDGE).GPJ TERRACON20 PROJECT: Emergency Bridge Package 6 SITE: SC 48 (Bluff Road) Richland County, South Carolina N 60 Value CPT Refused at 32 Feet WATER LEVEL OBSERVATION 9 ft estimated water depth (used in normalizations and correlations; see Appendix C) CPT CORRELATIVE PARAMETER LOG NO. CPT6 Page 1 of 1 SEE CPT LOG NO. CPT6 FOR DETAILED TEST RESULTS Effective Friction Angle (degrees) (1) (2) Notes: Probe no. 426 with net area ratio of 0.83 Manufactured by Geotech A.B.; calibrated 12/7/201 Tip and sleeve areas of cm 2 and 10 cm 2 Ring friction reducer with O.D. of 1.87 in CLIENT: SCDOT Columbia, SC Undrained Shear Strength, S u Nkt = 14 (tsf) TEST LOCATION: CPT Completed: /3/2016 Operator: JB Station: WBL Offset: Lane Ctr Tip resistance, sleeve resistance, porewater pressure, and tilt angle are measured. Other parameters presented are derived from interpretations of the measured data, based upon published correlations, but do not necessarily represent actual values that would be derived from direct testing. Appendix C provides the formulas used for these correlations and presents estimates of the relative reliability associated with the correlated parameters. 21 Clemson Rd Columbia, SC OCR (1) (2) CPT Started: /3/2016 Rig: Pagani TG73200 Project No.: 73100L See Exhibit A4 Surface Elev.: ft Latitude: Longitude: Elastic Modulus, E s (tsf) (3) (4) Exhibit: A28 Material Description Normalized CPT Soil Behavior Type Elev

59 Geotechnical Data Report Emergency Bridge Package 6 Richland County, SC May 12, 2016 Terracon Project No L (Rev. 1) 1. Photograph of rig on B1 2. Photograph of rig on B2 3. Photograph of rig on B3 4. Photograph of rig on B4. Photograph of rig on B 6. Photograph of rig on B6 Responsive Resourceful Reliable Exhibit A29

60 Geotechnical Data Report Emergency Bridge Package 6 Richland County, SC May 12, 2016 Terracon Project No L (Rev. 1) 7. Photograph of rig on CPT1 8. Photograph of rig on CPT2 9. Photograph of rig on CPT3. Photograph of rig on CPT4 11. Photograph of rig on CPT 12. Photograph of rig on CPT6 Responsive Resourceful Reliable Exhibit A29

61 Geotechnical Data Report Emergency Bridge Package 6 Richland County, SC May 12, 2016 Terracon Project No L (Rev. 1) 13. Photograph of MASW Array Back Swamp Bridge 14. Photograph of MASW Array Cedar Branch Bridge 1. Photograph of MASW Array Dry Branch Bridge Responsive Resourceful Reliable Exhibit A29

62 APPENDIX B LABORATORY TESTING Exhibit B1 Laboratory Testing Description Exhibit B2 Summary of Laboratory Data Exhibit B3 Laboratory Data Sheets

63 Geotechnical Data Report Emergency Bridge Package 6 Richland County, SC May 12, 2016 Terracon Project No L (Rev. 1) LABORATORY TESTING DESCRIPTION The samples collected during the field exploration were taken to our laboratory for additional testing. The laboratory testing program was developed by Terracon at the request of the SCDOT. Using the determined testing program, the laboratory tests were conducted on selected soil samples to determine lithological information. The test results are presented in this appendix The laboratory test results were used to confirm the soil descriptions presented on the boring logs in Appendix A. Laboratory tests were performed in general accordance with the applicable ASTM, AASHTO, SCDOT or other accepted standards. Selected soil samples obtained from the site were tested for the following engineering properties: Material Finer than No. 200 Sieve by Washing AASHTO T88/(ASTM D114014) Atterberg Limits AASHTO T89/T90(ASTM D4318) Moisture Content Determination AASHTO T26/(ASTM D2216) Responsive Resourceful Reliable Exhibit B1

64 Summary of Laboratory Results Sheet 1 of 1 BORING ID USCS Classification and Soil Description Compressive Strength (tsf) Liquid Limit Plastic Limit Plasticity Index % <#200 Sieve % Gravel % Sand % Silt % Clay Water Content (%) Dry Density (pcf) B B1 7 9 SANDY LEAN CLAY(CL) B B B B SANDY LEAN CLAY(CL) B B B B LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. OLDLAB SUMMARY: USCS 73100L LAB TESTING LENEXA.GPJ TERRACON2012.GDT /12/16 B3 4 6 CLAYEY SAND(SC) B B B B B CLAYEY SAND(SC) B B B B B B B B B B B B B SANDY SILT(ML) B PROJECT: Emergency Bridge Package 6 SITE: SC 48 (Bluff Road) Richland County, South Carolina 21 Clemson Rd Columbia, SC PROJECT NUMBER: 73100L CLIENT: SCDOT Columbia, SC EXHIBIT: B2

65 ATTERBERG LIMITS RESULTS ASTM D LABORATORY TESTS ARE NOT VALID IF SEPARATED FROM ORIGINAL REPORT. ATTERBERG LIMITS 73100L LAB TESTING LENEXA.GPJ TERRACON201.GDT /12/16 P L A S T I C I T Y I N D E X CL or OL CH or OH MH or OH CLML ML or OL Boring ID LL PL PI Fines USCS Description B1 B1 B2 B2 B3 B3 B4 B4 B B6 B PROJECT: Emergency Bridge Package 6 SITE: SC 48 (Bluff Road) Richland County, South Carolina "U" Line "A" Line LIQUID LIMIT CL CL SC SC ML 21 Clemson Rd Columbia, SC SANDY LEAN CLAY SANDY LEAN CLAY CLAYEY SAND CLAYEY SAND SANDY SILT PROJECT NUMBER: 73100L CLIENT: SCDOT Columbia, SC EXHIBIT: B3

66 APPENDIX C SUPPORTING DOCUMENTS Exhibit C1 Unified Soil Classification System Exhibit C2 CPT General Notes Exhibit C3 Rig Calibration Report

67 UNIFIED SOIL CLASSIFICATION SYSTEM Criteria for Assigning Group Symbols and Group Names Using Laboratory Tests A Coarse Grained Soils: More than 0% retained on No. 200 sieve FineGrained Soils: 0% or more passes the No. 200 sieve Gravels: More than 0% of coarse fraction retained on No. 4 sieve Sands: 0% or more of coarse fraction passes No. 4 sieve Silts and Clays: Liquid limit less than 0 Silts and Clays: Liquid limit 0 or more Group Symbol Soil Classification Group Name B Clean Gravels: E Cu ³ 4 and 1 Cc 3 GW F Wellgraded gravel Less than % fines C Cu < 4 and/or 1 > Cc > 3 E GP Poorly graded gravel F Gravels with Fines: Fines classify as ML or MH GM F,G,H Silty gravel More than 12% fines C Fines classify as CL or CH GC Clayey gravel F,G,H Clean Sands: E Cu ³ 6 and 1 Cc 3 SW I Wellgraded sand Less than % fines D Cu < 6 and/or 1 > Cc > 3 E SP Poorly graded sand I Sands with Fines: Fines classify as ML or MH SM G,H,I Silty sand More than 12% fines D Fines classify as CL or CH SC Clayey sand G,H,I Inorganic: Organic: Inorganic: Organic: PI > 7 and plots on or above A line J CL Lean clay K,L,M PI < 4 or plots below A line J ML Silt K,L,M Liquid limit oven dried Organic clay K,L,M,N < 0.7 OL Liquid limit not dried Organic silt K,L,M,O PI plots on or above A line CH Fat clay K,L,M PI plots below A line MH Elastic Silt K,L,M Liquid limit oven dried Liquid limit not dried < 0.7 OH Highly organic soils: Primarily organic matter, dark in color, and organic odor PT Peat Organic clay K,L,M,P Organic silt K,L,M,Q A Based on the material passing the 3inch (7mm) sieve B If field sample contained cobbles or boulders, or both, add with cobbles or boulders, or both to group name. C Gravels with to 12% fines require dual symbols: GWGM wellgraded gravel with silt, GWGC wellgraded gravel with clay, GPGM poorly graded gravel with silt, GPGC poorly graded gravel with clay. D Sands with to 12% fines require dual symbols: SWSM wellgraded sand with silt, SWSC wellgraded sand with clay, SPSM poorly graded sand with silt, SPSC poorly graded sand with clay E Cu = D60/D Cc = D (D 30 ) 2 x D 60 F If soil contains ³ 1% sand, add with sand to group name. G If fines classify as CLML, use dual symbol GCGM, or SCSM. H If fines are organic, add with organic fines to group name. I If soil contains ³ 1% gravel, add with gravel to group name. J If Atterberg limits plot in shaded area, soil is a CLML, silty clay. K If soil contains 1 to 29% plus No. 200, add with sand or with gravel, whichever is predominant. L If soil contains ³ 30% plus No. 200 predominantly sand, add sandy to group name. M If soil contains ³ 30% plus No. 200, predominantly gravel, add gravelly to group name. N PI ³ 4 and plots on or above A line. O PI < 4 or plots below A line. P PI plots on or above A line. Q PI plots below A line. Exhibit C1

68 CPT GENERAL NOTES DESCRIPTION OF MEASUREMENTS AND CALIBRATIONS To be reported per ASTM D778: Uncorrected Tip Resistance, q c Measured force acting on the cone divided by the cone's projected area Corrected Tip Resistance, q t Cone resistance corrected for porewater and net area ratio effects q t = q c + U2(1 a) Where a is the net area ratio, a lab calibration of the cone typically between 0.70 and 0.8 Pore Pressure, U1/U2 Pore pressure generated during penetration U1 sensor on the face of the cone U2 sensor on the shoulder (more common) Sleeve Friction, fs Frictional force acting on the sleeve divided by its surface area Normalized Friction Ratio, FR The ratio as a percentage of fs to q t, accounting for overburden pressure To be reported per ASTM D7400, if collected: Shear Wave Velocity, Vs Measured in a Seismic CPT and provides direct measure of soil stiffness Permeability, k Sand DESCRIPTION OF GEOTECHNICAL CORRELATIONS Normalized Tip Resistance, Q t Q t = (q t V0)/ ' V0 Over Consolidation Ratio, OCR OCR (1) = 0.2(Q t ) 1.2 OCR (2) = 0.33(Q t ) Undrained Shear Strength, Su Su = Q t x ' V0 /N kt N kt is a geographical factor (shown on Su plot) Sensitivy, St St = (q t V0/N kt ) x (1/fs) Effective Friction Angle, ' ' (1) = tan 1 (0.373[log(q t / ' V0 ) ]) ' (2) = [log(Q t )] Unit Weight UW = (0.27[log(FR)]+0.36[log(q t /atm)]+1.236) x UW water V0 is taken as the incremental sum of the unit weights Small Strain Shear Modulus, G 0 G 0 (1) = Vs 2 G 0 (2) = 0.01 x (0.Ic ) (q t V0) REPORTED PARAMETERS CPT logs as provided, at a minimum, report the data as required by ASTM D778 and ASTM D7400 (if applicable). This minimum data include tip resistance, sleeve resistance, and porewater pressure. Other correlated parameters may also be provided. These other correlated parameters are interpretations of the measured data based upon published and reliable references, but they do not necessarily represent the actual values that would be derived from direct testing to determine the various parameters. The following chart illustrates estimates of reliability associated with correlated parameters based upon the literature referenced below. RELATIVE RELIABILITY OF CPT CORRELATIONS Clay and Silt Soil Behavior Type Index, Ic Ic = [(3.47 log(q t ) 2 + (log(fr) ) 2 ] 0. SPT N 60 ( Ic) N 60 = (q t /atm) / Elastic Modulus, Es (assumes q/q ultimate ~ 0.3, i.e. FS = 3) Es (1) = 2.6 G 0 where = logQ t,clean sand Es (2) = G 0 Es (3) = 0.01 x (0.Ic ) (q t V0) Es (4) = 2.q t Constrained Modulus, M M = M(q t V0) For Ic > 2.2 (finegrained soils) M = Q t with maximum of 14 For Ic < 2.2 (coarsegrained soils) (0.Ic ) M = x Hydraulic Conductivity, k ( Ic) For 1.0 < Ic < 3.27 k = ( Ic) For 3.27 < Ic < 4.0 k = Relative Density, Dr Dr = (Q t / 30) 0. x 0 Constrained Modulus, M Effective Friction Angle, ' Relative Density, Dr CONE PENETRATION SOIL BEHAVIOR TYPE REFERENCES Unit Weight Sensitivity, St Undrained Shear Strength, Su Over Consolidation Ratio, OCR Small Strain Modulus, G 0 * and Elastic Modulus, Es* WATER LEVEL Sand Low Reliability Clay and Silt Clay and Silt Sand Clay and Silt Sand NORMALIZED CONE RESISTANCE, q t / atm 00 Sand 0 Clay and Silt * improves with seismic Vs measurements Reliability of CPTpredicted N 60 values as commonly measured by the Standard Penetration Test (SPT) is not provided due to the inherent inaccuracy associated with the SPT test procedure. High Reliability The groundwater level at the CPT location is used to normalize the measurements for vertical overburden pressures and as a result influences the normalized soil behavior type classification and correlated soil parameters. The water level may either be "measured" or "estimated:" Measured to water directly measured in the field Estimated to water interpolated by the practitioner using pore pressure measurements in coarse grained soils and known site conditions While groundwater levels displayed as "measured" more accurately represent site conditions at the time of testing than those "estimated," in either case the groundwater should be further defined prior to construction as groundwater level variations will occur over time. The estimated stratigraphic profiles included in the CPT logs are based on relationships between corrected tip resistance (q t ), friction resistance (fs), and porewater pressure (U2). The normalized friction ratio (FR) is used to classify the soil behavior type. Sand Sand Clay and Silt Clay and Silt Clay and Silt 7 1 Sensitive, fine grained 2 Organic soils clay 3 Clay silty clay to clay 4 Silt mixtures clayey silt to silty clay Typically, silts and clays have high FR values and Sand mixtures silty sand to sandy silt generate large excess penetration porewater pressures; sands have lower FRs and do not 6 Sands clean sand to silty sand generate excess penetration porewater pressures. 4 7 Gravelly sand to dense sand Negative pore pressure measurements are indicative of fissured finegrained material. The adjacent graph 3 8 Very stiff sand to clayey sand (Robertson et al.) presents the soil behavior type correlation used for the logs. This normalized SBT 9 Very stiff fine grained chart, generally considered the most reliable, does 1 not use pore pressure to determine SBT due to its 2 atm = atmospheric pressure = 1 kpa = 1.0 tsf lack of repeatability in onshore CPTs NORMALIZED FRICTION RATIO, FR Kulhawy, F.H., Mayne, P.W., (1997). "Manual on Estimating Soil Properties for Foundation Design," Electric Power Research Institute, Palo Alto, CA. Mayne, P.W., (2013). "Geotechnical Site Exploration in the Year 2013," Georgia Institue of Technology, Atlanta, GA. Robertson, P.K., Cabal, K.L. (2012). "Guide to Cone Penetration Testing for Geotechnical Engineering," Signal Hill, CA. Schmertmann, J.H., (1970). "Static Cone to Compute Static Settlement over Sand," Journal of the Soil Mechanics and Foundations Division, 96(SM3), Exhibit C1 C2

69 DRILL RIG SPT HAMMER ENERGY CALIBRATION REPORT Drill Rig Model CME0X SN Terracon Drill Rig No. 97 Columbia, SC October, 201 Project No Prepared for: Terracon Consultants, Inc. Columbia, SC Prepared by: Terracon Consultants, Inc. North Charleston, SC

70 October, 201 Terracon Consultants Inc. 21 Clemson Road Columbia, SC Attn: Re: Mr. Phillip Morrison P: (803) M: (803) E: SPT Rig Calibration Report Columbia, SC Terracon Project Number: Mr. Morrison: The Charleston office of Terracon Consultants, Inc. (Terracon) has completed the SPT rig calibration for the above referenced rig. This report provides Energy Transfer Ratio (ETR) for the SPT hammer found on CME0X (Serial Number ). We appreciate the opportunity to be of service to you on this project. If you have any questions concerning this report, or if we may be of further service, please contact us. Sincerely, Terracon Consultants, Inc. Yulian A. Kebede, Project Manager Geotechnical Services Bryan T. Shiver, P.E. Department Manager Geotechnical Services SC Registration No Terracon Consultants, Inc. 140 Fifth Street West North Charleston, South Carolina 2940 P [843] F [843 ] terracon.com

Geotechnical Data Report

Geotechnical Data Report Geotechnical Data Report S-38-50 (Four Holes Road) over I-26 Emergency Bridge Replacement Orangeburg County, South Carolina May 22, 2018 (Revision 1) SCDOT Project ID.: P037465 Terracon Project No. 73155050U

More information

Preliminary Geotechnical Data Report

Preliminary Geotechnical Data Report Preliminary Geotechnical Data Report Emergency Bridge Package 3 S101 (River Road) Martin Bridge Replacement Fairfield County, South Carolina November 10, 2015 (Rev. 1) Terracon Project No. 73155050F Prepared

More information

Project: ITHACA-TOMPKINS REGIONAL AIRPORT EXPANSION Project Location: ITHACA, NY Project Number: 218-34 Key to Soil Symbols and Terms TERMS DESCRIBING CONSISTENCY OR CONDITION COARSE-GRAINED SOILS (major

More information

B-1 BORE LOCATION PLAN. EXHIBIT Drawn By: 115G BROOKS VETERINARY CLINIC CITY BASE LANDING AND GOLIAD ROAD SAN ANTONIO, TEXAS.

B-1 BORE LOCATION PLAN. EXHIBIT Drawn By: 115G BROOKS VETERINARY CLINIC CITY BASE LANDING AND GOLIAD ROAD SAN ANTONIO, TEXAS. N B-1 SYMBOLS: Exploratory Boring Location Project Mngr: BORE LOCATION PLAN Project No. GK EXHIBIT Drawn By: 115G1063.02 GK Scale: Checked By: 1045 Central Parkway North, Suite 103 San Antonio, Texas 78232

More information

Geotechnical Data Report

Geotechnical Data Report Geotechnical Data Report Downtown Greenville Future Conveyance Study December 1, 2015 Terracon Project No. 86155032 Prepared for: Prepared by: Terracon Consultants, Inc. December 1, 2015 561 Mauldin Road

More information

Geotechnical Subsurface Exploration and Laboratory Testing Data Report

Geotechnical Subsurface Exploration and Laboratory Testing Data Report Geotechnical Subsurface Exploration and Laboratory Testing Data Report 2016 1A Emergency Bridge Replacement Package SCDOT PIN P030784 S 13 (East National Cemetery Road) Bridge over Long Branch Florence

More information

Geotechnical Subsurface Exploration and Laboratory Testing Data Report

Geotechnical Subsurface Exploration and Laboratory Testing Data Report Geotechnical Subsurface Exploration and Laboratory Testing Data Report 2016 1A Emergency Bridge Replacement Package SCDOT PIN P031819 S 19 (Highway 19 East) Bridge over Bug Swamp Horry County, South Carolina

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report Turner Turnpike Widening Bridge B Bridge Crossing: South 257 th West Avenue Creek County, Oklahoma June 1, 2016 Terracon Project No. 04155197 Prepared for: Garver, LLC Tulsa,

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report Turner Turnpike Widening Polecat Creek Bridge (Bridge A) June 1, 2016 Terracon Project No. 04155197 Prepared for: Garver, LLC Prepared by: Terracon Consultants, Inc. TABLE

More information

SOIL CLASSIFICATION CHART COARSE-GRAINED SOILS MORE THAN 50% RETAINED ON NO.200 SIEVE FINE-GRAINED SOILS 50% OR MORE PASSES THE NO.200 SIEVE PRIMARY DIVISIONS GRAVELS MORE THAN 50% OF COARSE FRACTION RETAINED

More information

B-1 SURFACE ELEVATION

B-1 SURFACE ELEVATION 5A 5B LOGGED BY El. S. Bhangoo DRILLING CONTRACTOR Pitcher Drilling DRILLING METHOD Rotary Wash BEGIN DATE 12-14-12 SAMPLER TYPE(S) AND SIZE(S) (ID) SPT, MC BOREHOLE BACKFILL AND COMPLETION COMPLETION

More information

Civil Engineering, Surveying and Environmental Consulting WASP0059.ltr.JLS.Mich Ave Bridge Geotech.docx

Civil Engineering, Surveying and Environmental Consulting WASP0059.ltr.JLS.Mich Ave Bridge Geotech.docx 2365 Haggerty Road South * Canton, Michigan 48188 P: 734-397-3100 * F: 734-397-3131 * www.manniksmithgroup.com August 29, 2012 Mr. Richard Kent Washtenaw County Parks and Recreation Commission 2330 Platt

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report Turner Turnpike Widening Bridge D Bridge Crossing: South 209 th West Avenue Creek County, Oklahoma June 1, 2016 Terracon Project No. 04155197 Prepared for: Garver, LLC Tulsa,

More information

Photo 1 - Southerly view across 2700 parking lot toward existing building. Multi-residential building borders western side of property in upper right of view. Photo 2 - Southerly view across 2750 parking

More information

APPENDIX C HYDROGEOLOGIC INVESTIGATION

APPENDIX C HYDROGEOLOGIC INVESTIGATION Figure B-5.7 Figure B-5.8 Preliminary Geotechnical and Environmental Report Appendix C Hydrogeologic Investigation APPENDIX C HYDROGEOLOGIC INVESTIGATION December 21, 2011 WESTSIDE SUBWAY EXTENSION PROJECT

More information

Depth (ft) USCS Soil Description TOPSOIL & FOREST DUFF

Depth (ft) USCS Soil Description TOPSOIL & FOREST DUFF Test Pit No. TP-6 Location: Latitude 47.543003, Longitude -121.980441 Approximate Ground Surface Elevation: 1,132 feet Depth (ft) USCS Soil Description 0 1.5 1.5 5.0 SM 5.0 8.0 SM Loose to medium dense,

More information

DATA REPORT GEOTECHNICAL INVESTIGATION GALVESTON CRUISE TERMINAL 2 GALVESTON, TEXAS

DATA REPORT GEOTECHNICAL INVESTIGATION GALVESTON CRUISE TERMINAL 2 GALVESTON, TEXAS DATA REPORT GEOTECHNICAL INVESTIGATION GALVESTON CRUISE TERMINAL 2 GALVESTON, TEXAS SUBMITTED TO PORT OF GALVESTON 123 ROSENBERG AVENUE, 8TH FLOOR GALVESTON, TEXAS 77553 BY HVJ ASSOCIATES, INC. HOUSTON,

More information

Field Exploration. March 31, J-U-B ENGINEERS, Inc. 115 Northstar Avenue Twin Falls, Idaho Attn: Mr. Tracy Ahrens, P. E. E:

Field Exploration. March 31, J-U-B ENGINEERS, Inc. 115 Northstar Avenue Twin Falls, Idaho Attn: Mr. Tracy Ahrens, P. E. E: March 31, 201 11 Northstar Avenue 83301 Attn: Mr. Tracy Ahrens, P. E. E: taa@jub.com Re: Geotechnical Data Report Preliminary Phase 1 Field Exploration Revision No. 1 Proposed Rapid Infiltration Basin

More information

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants SUBSURFACE SOIL EXPLORATION 42-INCH FORCE MAIN REPLACEMENT CHIQUITA BOULEVARD S AND SW 34 TH STREET CAPE CORAL, LEE COUNTY, FLORIDA Ardaman & Associates, Inc. Geotechnical, Environmental and Materials

More information

December 5, Junction Gateway, LLC 7551 W. Sunset Boulevard #203 Los Angeles, CA Mr. James Frost P: Dear Mr.

December 5, Junction Gateway, LLC 7551 W. Sunset Boulevard #203 Los Angeles, CA Mr. James Frost P: Dear Mr. December 5, 2014 Junction Gateway, LLC 7551 W. Sunset Boulevard #203 90046 Attn: Re: Mr. James Frost P: 323.883.1800 Geotechnical Update Letter Sunset & Effie Mixed Use Development 4301 to 4311 Sunset

More information

ENGINEERING ASSOCIATES

ENGINEERING ASSOCIATES July 16, 211 Vista Design, Inc. 11634 Worcester Highway Showell, Maryland 21862 Attention: Reference: Dear Mr. Polk: Mr. Richard F. Polk, P.E. Geotechnical Engineering Report Charles County RFP No. 11-9

More information

Geotechnical Data Report

Geotechnical Data Report Geotechnical Data Report ReWa Solar Farm at Durbin Creek Fountain Inn, South Carolina September 1, 2017 Terracon Project No. 86165043 Prepared for: Renewable Water Resources Greenville, South Carolina

More information

Preliminary Geotechnical Investigation Cadiz / Trigg County I-24 Business Park. Cadiz, Kentucky

Preliminary Geotechnical Investigation Cadiz / Trigg County I-24 Business Park. Cadiz, Kentucky Environmental & Geoscience, LLC 834 Madisonville Road Hopkinsville, KY 440 70.44.000 FAX 70.44.8300 www.wedrill.com A member of Trinity Energy & Infrastructure Group, LLC Preliminary Geotechnical Investigation

More information

GEOTECHNICAL REPORT. Matanuska-Susitna Borough. Parks Highway Connections Museum Drive. Matanuska-Susitna Borough, Alaska.

GEOTECHNICAL REPORT. Matanuska-Susitna Borough. Parks Highway Connections Museum Drive. Matanuska-Susitna Borough, Alaska. Matanuska-Susitna Borough GEOTECHNICAL REPORT Parks Highway Connections Museum Drive Matanuska-Susitna Borough, Alaska March 2, 20 Prepared By: John Thornley, PE Geotechnical Engineer 333 Arctic Blvd.,

More information

Pierce County Department of Planning and Land Services Development Engineering Section

Pierce County Department of Planning and Land Services Development Engineering Section Page 1 of 7 Pierce County Department of Planning and Land Services Development Engineering Section PROJECT NAME: DATE: APPLICATION NO.: PCDE NO.: LANDSLIDE HAZARD AREA (LHA) GEOLOGICAL ASSESSMENT REPORT

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report SH-9 Bridge over Wewoka Creek Hughes County, Oklahoma Job Piece No. 27059(04) July 16, 2015 Terracon Project No. 04125055 Prepared for: Holloway, Updike, and Bellen, Inc.

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report Richland Creek Trunk Sewer Greenville, South Carolina March 31, 2014 Terracon Project No. 86145008 Prepared for: Renewable Water Resources Greenville, South Carolina Prepared

More information

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants SUBSURFACE SOIL EXPLORATION DRAINAGE IMPROVEMENTS TO THE HENDRY COUNTY, FLORIDA Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants OFFICES Orlando, 88 S. Orange Avenue, Orlando,

More information

APPENDIX C. Borehole Data

APPENDIX C. Borehole Data APPENDIX C Borehole Data MAJOR DIVISIONS SOIL CLASSIFICATION CHART SYMBOLS GRAPH LETTER TYPICAL DESCRIPTIONS ADDITIONAL MATERIAL

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report Single-Span Bridge North Western Road & Hall of Fame Avenue August 25, 2015 Terracon Project No. 03155156 Prepared for: Olsson Associates Prepared by: Terracon Consultants,

More information

APPENDIX E SOILS TEST REPORTS

APPENDIX E SOILS TEST REPORTS Otsego County, NY Site Work Specifications APPENDIX E SOILS TEST REPORTS Blue Wing Services, Inc. July 1, 2010 Blue Wing Services May 20, 2010 Page 2 the site, was not made available to Empire at this

More information

M E M O R A N D U M. Mr. Jonathan K. Thrasher, P.E., Mr. Ian Kinnear, P.E. (FL) PSI

M E M O R A N D U M. Mr. Jonathan K. Thrasher, P.E., Mr. Ian Kinnear, P.E. (FL) PSI M E M O R A N D U M TO: FROM: Mr. Mark Schilling Gulf Interstate Engineering Mr. Jonathan K. Thrasher, P.E., Mr. Ian Kinnear, P.E. (FL) PSI DATE: November 11, 2014 RE: Summary of Findings Geotechnical

More information

Boreholes. Implementation. Boring. Boreholes may be excavated by one of these methods: 1. Auger Boring 2. Wash Boring 3.

Boreholes. Implementation. Boring. Boreholes may be excavated by one of these methods: 1. Auger Boring 2. Wash Boring 3. Implementation Boreholes 1. Auger Boring 2. Wash Boring 3. Rotary Drilling Boring Boreholes may be excavated by one of these methods: 4. Percussion Drilling The right choice of method depends on: Ground

More information

Report of Preliminary Geotechnical Exploration. CSO-012 Sewer Separation Cincinnati, Hamilton County, Ohio. February, 2011

Report of Preliminary Geotechnical Exploration. CSO-012 Sewer Separation Cincinnati, Hamilton County, Ohio. February, 2011 11242843_GeoTech_Preliminary - Feburary 2011_1/40 Report of Preliminary Geotechnical Exploration CSO-012 Sewer Separation Cincinnati, Hamilton County, Ohio February, 2011 11242843_GeoTech_Preliminary -

More information

DRILL HOLE # BH-BGC13-FN-01

DRILL HOLE # BH-BGC13-FN-01 DILL HOLE # BH-BGC3-FN-0 Drill Method: Mud otary/coring Depth To ock (m): N/A Page of 7 eviewed by: AJB 0 GAVEL (GW) Fine to coarse, sandy, well graded, dense, max particle size = 30 mm, angular to subrounded,

More information

New WW Hastings Hospital Geotechnical Investigation RFP Addendum #1

New WW Hastings Hospital Geotechnical Investigation RFP Addendum #1 88 E. Marshall Street, Suite 0 Tulsa, OK 76 98 8 9 Phone 98 8 798 FAX DATE: April 9, 0 ADDENDUM NO.: PROJECT: New WW Hastings Hospital BID PACKAGE NO: Geotechnical Investigation RFP SUBMITTED BY: CNCR

More information

CITY OF VALDEZ Project Title: East Pioneer Reconstruction Project No.: Contract No.: TO: All Recipients Date: April 14, 2014

CITY OF VALDEZ Project Title: East Pioneer Reconstruction Project No.: Contract No.: TO: All Recipients Date: April 14, 2014 CITY OF VALDEZ Project Title: East Pioneer Reconstruction Project No.: 13-3-1.32 Contract No.: 11 TO: All Recipients Date: April 14, 214 SUBJECT: Addendum No.1 This seventeen (17) page Addendum forms a

More information

Parsons APPENDIX A BORING LOGS AND DEVELOPMENT LOG

Parsons APPENDIX A BORING LOGS AND DEVELOPMENT LOG Parsons APPENDIX A BORING LOGS AND DEVELOPMENT LOG GEOLOGIC LOG DATE STARTED: DATE COMPLETED: 08-Sep-09 08-Sep-09 LOGGER: Quin Kinnebrew WEATHER: Clear & Warm PAGE 1 OF 2 WELL NO. GMW-66 COMPANY NAME:

More information

APPENDIX A GEOTECHNICAL REPORT

APPENDIX A GEOTECHNICAL REPORT The City of Winnipeg Bid Opportunity No. 529-2017 Template Version: C420170317 - RW APPENDIX A GEOTECHNICAL REPORT Quality Engineering Valued Relationships KGS Group 2017 Industrial Street Rehabilitation

More information

Appendix G GEOLOGICAL INVESTIGATION

Appendix G GEOLOGICAL INVESTIGATION Appendix G GEOLOGICAL INVESTIGATION JOB NUMBER: 3268.001 DATE: 10-14-13 BY: CC SITE 0 2000 1"=2000' VICINITY MAP CARGILL PARCEL HICKORY STREET AND ENTERPRISE DRIVE NEWARK, CALIFORNIA FOR

More information

TP-1 N61E 0 DARK BROWN SANDY SILT (ML) stiff, wet with roots (Disturbed Surficial Soil) DEPTH (FEET) 5 REDDISH BROWN SANDSTONE intensely fractured, weak to friable, deeply weathered, tight (Franciscan

More information

Limited Geotechnical Engineering Evaluation Classroom Additions Albany County Campus Laramie, Wyoming

Limited Geotechnical Engineering Evaluation Classroom Additions Albany County Campus Laramie, Wyoming Limited Geotechnical Engineering Evaluation Classroom Additions Albany County Campus 2300 Missile Drive, Cheyenne, Wyoming 82001 Phone 307-635-0222 www.stratageotech.com Limited Geotechnical Engineering

More information

Chapter 12 Subsurface Exploration

Chapter 12 Subsurface Exploration Page 12 1 Chapter 12 Subsurface Exploration 1. The process of identifying the layers of deposits that underlie a proposed structure and their physical characteristics is generally referred to as (a) subsurface

More information

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants SUBSURFACE SOIL EXPLORATION ANALYSIS AND RECOMMENDATIONS LELY AREA STORMWATER IMPROVEMENT PROJECT (LASIP) COUNTY BARN ROAD AND WING SOUTH CHANNELS NAPLES, COLLIER CO., FLORIDA Ardaman & Associates, Inc.

More information

APPENDIX A. Borehole Logs Explanation of Terms and Symbols

APPENDIX A. Borehole Logs Explanation of Terms and Symbols APPENDIX A Borehole Logs Explanation of Terms and Symbols Page 153 of 168 EXPLANATION OF TERMS AND SYMBOLS The terms and symbols used on the borehole logs to summarize the results of field investigation

More information

AN EMPLOYEE OWNED COMPANY

AN EMPLOYEE OWNED COMPANY CTL Engineering, Inc. 2860 Fisher Road, P.O. Box 4448, Columbus, Ohio 43204338 Phone: 614/2768123 Fax: 614/2766377 Email: ctl@ctleng.com AN EMPLOYEE OWNED COMPANY Consulting Engineers Testing Inspection

More information

IN SITU SPECIFIC GRAVITY VS GRAIN SIZE: A BETTER METHOD TO ESTIMATE NEW WORK DREDGING PRODUCTION

IN SITU SPECIFIC GRAVITY VS GRAIN SIZE: A BETTER METHOD TO ESTIMATE NEW WORK DREDGING PRODUCTION IN SITU SPECIFIC GRAVITY VS GRAIN SIZE: A BETTER METHOD TO ESTIMATE NEW WORK DREDGING PRODUCTION Nancy Case O Bourke, PE 1, Gregory L. Hartman, PE 2 and Paul Fuglevand, PE 3 ABSTRACT In-situ specific gravity

More information

ADDENDUM 1 FISHER SLOUGH RESTORATION PROJECT SKAGIT COUNTY, WASHINGTON

ADDENDUM 1 FISHER SLOUGH RESTORATION PROJECT SKAGIT COUNTY, WASHINGTON F I N A L A D D E N D U M 1 R E P O R T ADDENDUM 1 FISHER SLOUGH RESTORATION PROJECT SKAGIT COUNTY, WASHINGTON REPORT OF GEOTECHNICAL INVESTIGATION URS JOB NO. 3376186 Prepared for Tetra Tech Inc. 142

More information

ATTACHMENT A PRELIMINARY GEOTECHNICAL SUMMARY

ATTACHMENT A PRELIMINARY GEOTECHNICAL SUMMARY ATTACHMENT A PRELIMINARY GEOTECHNICAL SUMMARY Kevin M. Martin, P.E. KMM Geotechnical Consultants, LLC 7 Marshall Road Hampstead, NH 0384 603-489-6 (p)/ 603-489-8 (f)/78-78-4084(m) kevinmartinpe@aol.com

More information

REPORT OF SUBSURFACE EXPLORATION

REPORT OF SUBSURFACE EXPLORATION REPORT OF SUBSURFACE EXPLORATION GRAND RIVER DAM AUTHORITY HULBERT 69 KV SWITCHING STATION S. 440 Road Hulbert, Cherokee County, Oklahoma ENERCON PROJECT NO. GRDA006 MARCH 7, 2012 PREPARED FOR: C/O ENERCON

More information

Geotechnical Recommendations for Proposed Additions to the Three Mile Creek Severe Weather Attenuation Tank Project

Geotechnical Recommendations for Proposed Additions to the Three Mile Creek Severe Weather Attenuation Tank Project TECHNICAL MEMORANDUM Geotechnical Recommendations for Proposed Additions to the Three Mile Creek Severe Weather Attenuation Tank Project PREPARED FOR: PREPARED BY: DATE: June 28, 218 PROJECT NUMBER: 697482

More information

PARQUE COLON AGUADILLA (LAND PROPERTY OF MUNICIPIO AGUADA) LOT PROPERTY OF SUNC. ESTEVEZ BW-1 BW-5 BW-2 DB1 BW-3 DB2 BW-4 DB3 GWS-1

PARQUE COLON AGUADILLA (LAND PROPERTY OF MUNICIPIO AGUADA) LOT PROPERTY OF SUNC. ESTEVEZ BW-1 BW-5 BW-2 DB1 BW-3 DB2 BW-4 DB3 GWS-1 N 64650 N 64600 N 64550 N 64500 N 64450 N 64400 N 64350 N 64300 N 64250 N 64200 N 64150 N 64100 N 64050 N 64000 N 63950 N 63900 N 63850 N 63800 N 63750 N 63700 N 63650 N 63600 N 63550 N 63500 N 63450 N

More information

ENCE 3610 Soil Mechanics. Site Exploration and Characterisation Field Exploration Methods

ENCE 3610 Soil Mechanics. Site Exploration and Characterisation Field Exploration Methods ENCE 3610 Soil Mechanics Site Exploration and Characterisation Field Exploration Methods Geotechnical Involvement in Project Phases Planning Design Alternatives Preparation of Detailed Plans Final Design

More information

Appendix A. Producer Statement Advisory Note

Appendix A. Producer Statement Advisory Note Appendix A Producer Statement Advisory Note Ref. No. 17095 26 May 2017 PRODUCER STATEMENT CONSTRUCTION REVIEW (PS4) IMPORTANT ADVISORY NOTE The Building Consent Authority (BCA) frequently requires Producer

More information

Northern Colorado Geotech

Northern Colorado Geotech PRELIMINARY GEOTECHNICAL ENGINEERING REPORT PROPOSED CECIL FARMS DEVELOPMENT WELD COUNTY ROAD 7, BETWEEN ROADS 7 AND 7 SEVERANCE, COLORADO NORTHERN COLORADO GEOTECH PROJECT NO. 0-6 APRIL 0, 06 Prepared

More information

Preliminary Geotechnical Evaluation Gooseberry Point Pedestrian Improvements Whatcom County, Washington SITE AND PROJECT DESCRIPTION

Preliminary Geotechnical Evaluation Gooseberry Point Pedestrian Improvements Whatcom County, Washington SITE AND PROJECT DESCRIPTION File No. 12-100 Geotechnical & Earthquake Engineering Consultants Mr. Kevin Brown, P.E. Gray & Osborne, Inc. 3710 168 th Street NE, Suite B210 Arlington, Washington 98223 Subject: Draft Report Preliminary

More information

SUPPLEMENTARY INVESTIGATION AND LABORATORY TESTING Aggregate Resource Evaluation Proposed Bernand Quarry San Diego County, California

SUPPLEMENTARY INVESTIGATION AND LABORATORY TESTING Aggregate Resource Evaluation Proposed Bernand Quarry San Diego County, California October 3, 2 Mr. Mark San Agustin Project No. 28-- Home Land Investments Document No. -92 2239 Curlew Street San Diego, CA 92 SUBJECT: SUPPLEMENTARY INVESTIGATION AND LABORATORY TESTING Aggregate Resource

More information

PRELIMINARY GEOTECHNICAL REPORT. State College Redevelopment State College Borough, Centre County, Pennsylvania. CMT Laboratories File No.

PRELIMINARY GEOTECHNICAL REPORT. State College Redevelopment State College Borough, Centre County, Pennsylvania. CMT Laboratories File No. PRELIMINARY GEOTECHNICAL REPORT State College Redevelopment State College Borough, Centre County, Pennsylvania CMT Laboratories File No. 1638700 Prepared for: National Development Council One Battery Park

More information

APPENDIX F CORRELATION EQUATIONS. F 1 In-Situ Tests

APPENDIX F CORRELATION EQUATIONS. F 1 In-Situ Tests APPENDIX F 1 APPENDIX F CORRELATION EQUATIONS F 1 In-Situ Tests 1. SPT (1) Sand (Hatanaka and Uchida, 1996), = effective vertical stress = effective friction angle = atmosphere pressure (Shmertmann, 1975)

More information

Project No: 68R3056 Client: City of Frederick Project: RFQ 14-H Future North Side Water Tank City/State: 7516 Hayward Road, Frederick, MD

Project No: 68R3056 Client: City of Frederick Project: RFQ 14-H Future North Side Water Tank City/State: 7516 Hayward Road, Frederick, MD Boring: SB-1 (1 of 1) Moist, brown to orange brown CLAY and SILT, trace sand with fine weathered rock fragments. POSSIBLE FILL. Dry, orange brown sandy SILT trace clay (SM-ML). RESIDUAL SOIL : Not Surveyed

More information

R-1 Conveyor Relocation Project Legend 0 500 1000 1500 ft. This map is a user generated static output from an Internet mapping site and is for general reference only. Data layers that appear on this map

More information

February 16, 2015 File No Ms. Robin Yates TRC Engineers Inc N. Fresno Street, Suite 200 Fresno, California 93710

February 16, 2015 File No Ms. Robin Yates TRC Engineers Inc N. Fresno Street, Suite 200 Fresno, California 93710 February 16, 2015 File No. 20152738 Ms. Robin Yates TRC Engineers Inc. 6051 N. Fresno Street, Suite 200 Fresno, California 93710 SUBJECT: Geotechnical Design Memorandum Fresno BPMP Scour Countermeasure

More information

CIVE.5370 EXPERIMENTAL SOIL MECHANICS Soil Sampling, Testing, & Classification Review

CIVE.5370 EXPERIMENTAL SOIL MECHANICS Soil Sampling, Testing, & Classification Review DATA COLLECTION, INTERPRETATION, & ANALYSIS TO GEOTECHNICAL SOLUTIONS FLOW CHART PRIOR INFORMATION Reconnaissance Topography Geology Hydrology Environment SITE EXPLORATION Geophysics Drilling and Coring

More information

From - To 0,00-4,90 4,90-6,40 6,40-8,60 8,60-9,60 9,60-10,50 10,50-12,00 12,00-14,80 14,80-15,80 15,80-19,30 19, ,00

From - To 0,00-4,90 4,90-6,40 6,40-8,60 8,60-9,60 9,60-10,50 10,50-12,00 12,00-14,80 14,80-15,80 15,80-19,30 19, ,00 Závěrka 12,Praha 6,169 00 Log of Boring BH1 Project ID: 2018_A-017 Annex no.: A.1G Drilling equipment: Hütte 202 TF Location: Prague 12 Overall depth: 2 m Borehole position: Date start: 22.11.2017 Foreman:

More information

PRELIMINARY GEOTECHNICAL ENGINEERING REPORT. Proposed Re-Development 44 Old Worcester Road Charlton, Massachusetts. Prepared For:

PRELIMINARY GEOTECHNICAL ENGINEERING REPORT. Proposed Re-Development 44 Old Worcester Road Charlton, Massachusetts. Prepared For: PRELIMINARY GEOTECHNICAL ENGINEERING REPORT Proposed Re-Development 44 Old Worcester Road Charlton, Massachusetts Prepared For: Meridian Associates, Inc. 500 Cummings Center, Suite 5950 Beverly, Massachusetts

More information

Geotechnical Engineering Study, Conifer Senior High School Football Field Improvements, Conifer, Colorado

Geotechnical Engineering Study, Conifer Senior High School Football Field Improvements, Conifer, Colorado 2390 South Lipan Street Denver, CO 80223 phone: (303) 742-9700 fax: (303) 742-9666 email: kadenver@kumarusa.com www.kumarusa.com Office Locations: Denver (HQ), Colorado Springs, Fort Collins, and Frisco,

More information

Dashed line indicates the approximate upper limit boundary for natural soils. C L o r O L C H o r O H

Dashed line indicates the approximate upper limit boundary for natural soils. C L o r O L C H o r O H SYMBOL SOURCE 8 9 1 SOIL DATA NATURAL SAMPLE DEPTH WATER PLASTIC LIQUID PLASTICITY NO. CONTENT LIMIT LIMIT INDEX (%) (%) (%) (%) Client: County of Berthoud Project: Project No.: Boring B-2 S-1-5' 6.2 8

More information

APPENDIX B: BORING LOGS

APPENDIX B: BORING LOGS New Orleans Levee Systems Independent Levee Hurricane Katrina Investigation Team July, 6 APPENDIX B: BORING S As part of the field investigation 9 borings were performed at the sites of interest, as listed

More information

BR-01 PAINT BRIDGE NO. 55 C GENERAL PLAN 720'-0" VC 605'-0" VC 1. FOR INDEX TO PLANS, QUANTITIES, AND GENERAL NOTES, SEE "INDEX TO PLANS" SHEET.

BR-01 PAINT BRIDGE NO. 55 C GENERAL PLAN 720'-0 VC 605'-0 VC 1. FOR INDEX TO PLANS, QUANTITIES, AND GENERAL NOTES, SEE INDEX TO PLANS SHEET. 2'-" VC 6'-" VC BB EB 1 1 1 1 1 TV - " TV CONDUITS (COX E 8 - " ELECTRIC CONDUITS (SDG & E T - " TELEPHONE CONDUITS 1. FOR INDEX TO PLANS, QUANTITIES, AND GENERAL NOTES, SEE "INDEX TO PLANS" SHEET. 2.

More information

NAPLES MUNICIPAL AIRPORT

NAPLES MUNICIPAL AIRPORT NAPLES MUNICIPAL AIRPORT NAPLES MUNICIPAL AIRPORT (APF) TAXIWAY D REALIGNMENT AND DRAINAGE IMPROVEMENTS NORTH QUADRANT ADDENDUM NUMBER TWO March, The following Addendum is hereby made a part of the Plans

More information

CITY OF CAPE CORAL NORTH 2 UTILITIES EXTENSION PROJECT CONTRACT 3

CITY OF CAPE CORAL NORTH 2 UTILITIES EXTENSION PROJECT CONTRACT 3 GEOTECHNICAL REPORT CITY OF CAPE CORAL NORTH UTILITIES EXTENSION PROJECT CONTRACT City of Cape Coral Procurement Division Cultural Park Boulevard, nd Floor Cape Coral, FL ISSUED FOR BID VOLUME of GEOTECHNICAL

More information

PLATE 6 FEB G r o v e l a n d F l o o d w a l l - B o r e h o l e M a p. Legend. Groveland Floodwall Boreholes. Contour Lines.

PLATE 6 FEB G r o v e l a n d F l o o d w a l l - B o r e h o l e M a p. Legend. Groveland Floodwall Boreholes. Contour Lines. 611 6 Defau FALS conto Conto DPLV lt Eurs20 01_to 3po Defau FALS conto Conto DPLV lt Eurs20 01_to 4po 612 Conto DPLV conto Defau FALS 01_to urs20 Elt po 5 Conto DPLV conto Defau FALS 01_to urs15 Elt po

More information

GEOTECHNICAL INVESTIGATION REPORT

GEOTECHNICAL INVESTIGATION REPORT GEOTECHNICAL INVESTIGATION REPORT SOIL INVESTIGATION REPORT FOR STATIC TEST FACILITY FOR PROPELLANTS AT BDL, IBRAHIMPATNAM. Graphics Designers, M/s Architecture & Engineering 859, Banjara Avenue, Consultancy

More information

GEOTECHNICAL ENGINEERING SERVICES REPORT

GEOTECHNICAL ENGINEERING SERVICES REPORT GEOTECHNICAL ENGINEERING SERVICES REPORT BRIDGE OVER BIG CREEK APPROXIMATELY.8 MILES EAST OF THE INTERSECTION OF COUNTY ROAD EW1546 AND COUNTY ROAD 193 LEFLORE COUNTY, OKLAHOMA PROJECT No. J2-8616(5),

More information

TIERRA. Florida License No Florida License No

TIERRA. Florida License No Florida License No March 9, 208 TIERRA AECOM 7650 West Courtney Campbell Cswy Tampa, FL 33607 Attn: RE: Mr. Edgar Figueroa, P.E. Geotechnical Engineering Services Report Purchase Order No.: 9532 AECOM Project Number: 6055499

More information

FIGURES 200 200 200 SW 175TH AVE 350 SW SCHOLLS FERRY RD SW FRIENDLY LN Area 64 SW ROY ROGERS RD 300 250 SW ONEILL CT SW LUKE LN SW LEEDING LN SW TUSCANY ST SW 164TH AVE SW BULL MOUNTAIN RD SW 164TH AVE

More information

The process of determining the layers of natural soil deposits that will underlie a proposed structure and their physical properties is generally

The process of determining the layers of natural soil deposits that will underlie a proposed structure and their physical properties is generally The process of determining the layers of natural soil deposits that will underlie a proposed structure and their physical properties is generally referred to as sub surface investigation 2 1 For proper

More information

GEOTECHNICAL SITE CHARACTERIZATION

GEOTECHNICAL SITE CHARACTERIZATION GEOTECHNICAL SITE CHARACTERIZATION Neil Anderson, Ph.D. Professor of Geology and Geophysics Richard W. Stephenson, P.E., Ph.D. Professor of Civil, Architectural and Environmental Engineering University

More information

Technical Memorandum. Soil Borings

Technical Memorandum. Soil Borings Technical Memorandum To: Project File and Appendix F to Sediment Remedial Investigation Report From: Sara L. Leow, PE Subject: Geotechnical Investigation and Results Summary Date: February 213 Project:

More information

December 20, 2017 (Revised from December 15, 2017) Project No

December 20, 2017 (Revised from December 15, 2017) Project No December 20, 2017 (Revised from December 15, 2017) Project No. 92270.02 Ms. Laura Krusinski, P.E. Senior Geotechnical Engineer Maine Department of Transportation State House Station 16 Augusta, Maine 04333-016

More information

PRELIMINARY GEOTECHNICAL ENGINEERING REPORT

PRELIMINARY GEOTECHNICAL ENGINEERING REPORT PRELIMINARY GEOTECHNICAL ENGINEERING REPORT TOWN OF ASHLAND TOWN HALL 101 THOMPSON STREET ASHLAND, VIRGINIA JOB NUMBER: 39016 PREPARED FOR: PMA PLANNERS & ARCHITECTS 10325 WARWICK BOULEVARD NEWPORT NEWS,

More information

LEGEND ODOT CLASS A-3. A-3a. A-4a. A-6a. A-6b TOTAL VISUAL VISUAL VISUAL BORING LOCATION - PLAN VIEW

LEGEND ODOT CLASS A-3. A-3a. A-4a. A-6a. A-6b TOTAL VISUAL VISUAL VISUAL BORING LOCATION - PLAN VIEW PROJECT THE PROJECT CONSISTS IN PART OF CONSTRUCTING A SINGLE-SPAN BRIDGE ON RELOCATED SHUMWAY HOOW ROAD OVER THE CSXT RAILROAD. THE STRUCTURE AS ANNED, IS A SINGLE-SPAN STRUCTURE WITH MSE WAS AT THE ABUTMENTS.

More information

The attitude he maintains in his relation to the engineer is very well stated in his own words:

The attitude he maintains in his relation to the engineer is very well stated in his own words: Su bsurface Soil Exploration, 53: 139 Foundation Engineering Geotechnical companies that have a history of experience in a given region usually have extensive boring logs and maps telling where the borings

More information

Conventional Field Testing & Issues (SPT, CPT, DCPT, Geophysical methods)

Conventional Field Testing & Issues (SPT, CPT, DCPT, Geophysical methods) Conventional Field Testing & Issues (SPT, CPT, DCPT, Geophysical methods) Ajanta Sachan Assistant Professor Civil Engineering IIT Gandhinagar Conventional Field Testing 1 Field Test: In-situ shear strength

More information

Hydro One (Sept 2014) Hydro One (Sept 2014) Hydro One (Sept 2014)

Hydro One (Sept 2014) Hydro One (Sept 2014) Hydro One (Sept 2014) TABLE 1 WELL CONSTRUCTION DETAILS MOE WWR No Well ID Location Installation Date Status Easting Coordinates Northing Source Elevation Screened Interval Screened Material Borehole Well Stick-up Ground Top

More information

Log of Monitoring Well D58B

Log of Monitoring Well D58B Project: Motiva - Monitoring Well and Soil Boring Data Project Location: Delaware City Refinery Project Number: 20240412.W1000 Log of Monitoring Well D58B Sheet 1 of 7 Date(s) Drilled Drilling Method Drill

More information

Geotechnical Investigation Juneau Seawalk - Taku Fisheries to Miner s Wharf Juneau, Alaska DM&A Job No

Geotechnical Investigation Juneau Seawalk - Taku Fisheries to Miner s Wharf Juneau, Alaska DM&A Job No Duane Miller & Associates 5821 Arctic Boulevard, Suite A Anchorage, AK 99518-1654 (907) 644-3200 Fax 644-0507 Arctic & Geotechnical Engineering May 4, 2006 Tetra Tech/KCM, Inc. 1971 First Avenue Seattle,

More information

REPORT OF PRELIMINARY GEOTECHNICAL SITE INVESTIGATION KERSHAW COUNTY EXIT 87 OFFICE PARK. ELGIN, SOUTH CAROLINA S&ME Project No.

REPORT OF PRELIMINARY GEOTECHNICAL SITE INVESTIGATION KERSHAW COUNTY EXIT 87 OFFICE PARK. ELGIN, SOUTH CAROLINA S&ME Project No. REPORT OF PRELIMINARY GEOTECHNICAL SITE INVESTIGATION KERSHAW COUNTY EXIT 87 OFFICE PARK ELGIN, SOUTH CAROLINA S&ME Project No. 1611-04-450 Prepared For: KERSHAW COUNTY ECONOMIC DEVELOPMENT OFFICE Post

More information

Geotechnical Investigation

Geotechnical Investigation Geotechnical Investigation Veterans Parkway Bridge Approaches Investigation Savannah, Georgia July 20, 2015 Terracon Project No. ES155020 Prepared for: Chatham County Engineering Department Savannah, Georgia

More information

Preliminary Geotechnical Engineering Report

Preliminary Geotechnical Engineering Report Preliminary Geotechnical Engineering Report Bruce and Lee Industrial Site Florence, South Carolina August 31, 2015 Terracon Project No. 73155060 Prepared by: Terracon Consultants, Inc. August 31, 2015

More information

PREPARED FOR MR. JOE WOOD CARTER & SLOOPE, INC PEAKE ROAD MACON, GEORGIA PREPARED BY

PREPARED FOR MR. JOE WOOD CARTER & SLOOPE, INC PEAKE ROAD MACON, GEORGIA PREPARED BY SUBSURFACE EXPLORATION AND GEOTECHNICAL ENGINEERING EVALUATION MACON WATER AUTHORITY (MWA) SANITARY SEWER RELOCATION MACON, GEORGIA GEC PROJECT NO. 14077.2 PREPARED FOR MR. JOE WOOD CARTER & SLOOPE, INC.

More information

SITE INVESTIGATION 1

SITE INVESTIGATION 1 SITE INVESTIGATION 1 Definition The process of determining the layers of natural soil deposits that will underlie a proposed structure and their physical properties is generally referred to as site investigation.

More information

patersongroup Design for Earthquakes Consulting Engineers May 19, 2016 File: PG3733-LET.01

patersongroup Design for Earthquakes Consulting Engineers May 19, 2016 File: PG3733-LET.01 patersongroup May 19, 2016 File: PG3733-LET.01 Hydro Ottawa Limited c/o Cresa Toronto 170 University Avenue, Suite 1 Toronto, Ontario M5H 3B3 Attention: Ms. Barbara Wright Consulting Engineers 154 Colonnade

More information

REPORT OF PRELIMINARY SUBSURFACE EXPLORATION. VCU Basketball Practice Facility 1300/1328 West Marshall Street City of Richmond, Virginia.

REPORT OF PRELIMINARY SUBSURFACE EXPLORATION. VCU Basketball Practice Facility 1300/1328 West Marshall Street City of Richmond, Virginia. REPORT OF PRELIMINARY SUBSURFACE EXPLORATION VCU Basketball Practice Facility 100/18 West Marshall Street City of Richmond, Virginia For Mr. Carl F. Purdin, AIA Assistant Director of Design Services VCU

More information

GEOTECHNICAL INVESTIGATION

GEOTECHNICAL INVESTIGATION GEOTECHNICAL INVESTIGATION I-80 WILDLIFE OVERCROSSING @ SILVER ZONE PASS ELKO COUNTY, NEVADA EA #73438 JULY 2011 MATERIALS DIVISION Table of Contents 1.0 INTRODUCTION... 1 2.0 PROJECT DESCRIPTION... 1

More information

LEGEND ODOT CLASS. A-4b. A-6a. A-6b TOTAL VISUAL WEATHERED SANDSTONE VISUAL BORING LOCATION - PLAN VIEW

LEGEND ODOT CLASS. A-4b. A-6a. A-6b TOTAL VISUAL WEATHERED SANDSTONE VISUAL BORING LOCATION - PLAN VIEW PROJECT THE PROJECT CONSISTS IN PART OF ACING TWO STRUCTURES, EASTBOUND AND WESTBOUND STRUCTURES, RESPECTIVELY FOR THE PROPOSED SR OVER BLUE ROAD (CR 9). THE TWO STRUCTURES AS ANNED, ARE SINGLE-SPAN STRUCTURES

More information

GEOTECHNICAL EXPLORATION REPORT

GEOTECHNICAL EXPLORATION REPORT 110001_Report_Geotech, 2/ GEOTECHNICAL EXPLORATION REPORT BENSON STREET SEWER REPLACEMENT READING, HAMILTON COUNTY, OHIO MSDGC PROJECT NO. 20031 PREPARED FOR AECOM 219 MALSBURY ROAD CINCINNATI, OHIO 22

More information

SUBSURFACE EXPLORATION REPORT FOR THE MARITIME INFRACTURE REHABILITATION AT WHISKEY ISLAND BULK TERMINAL CLEVELAND, OHIO PGI PROJECT NO.

SUBSURFACE EXPLORATION REPORT FOR THE MARITIME INFRACTURE REHABILITATION AT WHISKEY ISLAND BULK TERMINAL CLEVELAND, OHIO PGI PROJECT NO. SUBSURFACE EXPLORATION REPORT FOR THE MARITIME INFRACTURE REHABILITATION AT WHISKEY ISLAND BULK TERMINAL CLEVELAND, OHIO PGI PROJECT NO. G1G PREPARED FOR KS ASSOCIATES, INC. PREPARED BY PRO GEOTECH, INC.

More information

Soil Mechanics Brief Review. Presented by: Gary L. Seider, P.E.

Soil Mechanics Brief Review. Presented by: Gary L. Seider, P.E. Soil Mechanics Brief Review Presented by: Gary L. Seider, P.E. 1 BASIC ROCK TYPES Igneous Rock (e.g. granite, basalt) Rock formed in place by cooling from magma Generally very stiff/strong and often abrasive

More information

UNIT DESCRIPTIONS: Artificial Fill, Undocumented (Afu): Locally derived sandy silt and silty sand, locally with clay and varying amounts of gravel and man-made debris. Abundant concrete rubble, in places

More information