Safir-M smart. Features. Dot-matrix display and controls. Industries. Applications. y Reference accuracy, % FS
|
|
- Stephanie Jefferson
- 5 years ago
- Views:
Transcription
1
2
3
4 y Reference accuracy, % FS y Turndown :0 Features y Output 20 ma, 0 5 ma, HART 7.0 Linear (increasing or decreasing) Square root (differential pressure) y Damping predefined set (0; 0.5; 2.5; 6.0; 2.0; 8.0; 2.0; 2.0 s) user defined 0 2 s y Explosion protection Intrinsically safe 0ExiaIICT5X Explosion proof ExsdIIBT5 y Special design for oxygen media y Build-in dot-matrix display or handheld control unit y Warranty period 6 months, Inter calibration period 2 months y Self-diagnostic & Process monitoring y Resolution 28x28, RGB y Software rotation of display Dot-matrix display and controls y Parameters displayed: pressure, output, percent of span, sensor temperature y Functions Zero and upper range value adjustment Predefined range selection User defined upper range value (digital input) User defined variable (linear function of pressure) Display view customization Configuration via HART-protocol locking Polling address selection Three-level privilege Output trim Output function selection y Thermal power stations y Metallurgy y Oil & Gas production y Pipelines y Refinery & Chemicals y Machinery Industries Applications y Process management y Protection and safety systems y Custody transfer and Flow measurement
5 Pressure ranges Predefined pressure ranges are formed from the set (.0,.6, 2.5,.0, 6.) by decimal shifting to left or right. These values may be used with the following physical units: kpa (MPa), kgf/m2 (kgf/cm2), mbar (bar). The table bellow represents pressure ranges for particular model number. absolute gage gage (neg.) gage (neg./pos.) differential hydro Model number Ра кра MРа 0,0 6,0 00,0 60,0 250,0 00,0 60,0,0,6 2,5,0 6, 0,0 6,0 25,0 0,0 6,0 00,0 60,0 250,0 00,0 60,0,0,6 2,5,0 6, 0,0 6,0 25,0 0,0 6,0 00, , * , 7, 75 70, 72, 7, , , 77 * * , 72, , 722, 72, * , 7, 75 70, 72, 7, , * , 72 70, 7 70, 7 750, pressure level flow Notes. Span limits (min and max) are indicated. 2. LRV equals to 0 for absolute, gage, differential and hydrostatic pressure transmitters. Transmitters might be supplied being configured at PPR or user specified ranges with the following limitations: URV should be algebraically greater than LRV, except gage (negative) transmitter for which pressure axis is reversed URV shouldn t be more than URL for the model number Span shouldn t be less then minimal one for the model number. Transmitters with model numbers xx0 should be used for gases only with LRV = 0 5
6 Accuracy Hereafter all the metrological characteristics are expressed as output deviation relative to output range. Reference accuracy, % (includes hysteresis, linearity, and repeatability) Model numbers URV or Turndown xx0 0. kpa < URV URV 0. kpa xx0 TD < TD TD xx 0 < TD < TD TD others 6 < TD < TD Ambient temperature effect (per 0 C, ref. temp. 2 C) Ref. accuracy Temperature effect, % TD TD TD TD Static pressure effect Model numbers Static pressure, MPa Static pressure effect, % per x xtd 0. MPa x xtd MPa 2.5 < 0.2 xtd MPa x xtd MPa < xtd MPa xtd MPa x20 < xtd MPa 0 < xtd MPa x0, x0, x50 x, x, x5, x6 x520, x50, x50, x xtd MPa 0 < xtd MPa xtd MPa xtd MPa 2.5 < 0.2 xtd MPa Power supply effect, % per V Output variations, % to 5 Hz to 06 Hz Magnetic field effect < ref. acc. 00 A/m at 50 Hz Vibration effect, %.0xTD for xx0, xx0, xx5, xx20 0.xTD other model numbers Response time, s.6 for xx0, xx0 0.2 other model numbers 6
7 Operating conditions Ambient temperature & humidity (should be specified in ordering form) UHL.*(+5 +50) t (+5 +50) C, h 95± % at 5 C UHL.*(+5 +80) t (+5 +80) C, h 95± % at 5 C U2*(-0 +50) t (-0 +50) C, h 95± % at 5 C condensation not permissible U2*(-0 +50) t (-0 +50) C, h 95± % at 5 C T** t (-5 +80) C, h 00 % at 5 C condensation permissible *Max process temperature 20 C Static pressure limits (differential or hydrostatic pressure) Model number MPa , 7520, 750, 750, , 70, , 7, Overpressure Absolute and Gage pressure.5 of URL Differential pressure.5 of static pressure from high pressure side pressure level flow Permissible vibrations Mechanical Shock Frequency 9 Hz, amplitude, mm.5 Peak acceleration, m/s2 70 Frequency 9 50 Hz, acceleration, m/s2 0.0 Impulse duration, ms 50 Directions X,Y,Z Form half-wave Rate, /s 0. Directions X,Y,Z Ingress Protection Rating IP66 EMC Interference type Test level Criteria Additional error, % Electrostatic discharge IEC A 0. Radio-frequency electromagnetic field IEC A.0 Fast transient/ Burst immunity IEC A.0 Serge immunity IEC line-to-line line-to-ground A.0 Conducted disturbances IEC A 0. Pulse magnetic field immunity IEC A 0. Conducted, common mode disturbances in the frequency range 0 Hz to 50 khz IEC A.0 EM Interference Interference voltage on power supply lines Interference voltage [db μv] Frequency, MHz Average Quasi peak value value Emission limits Frequency, MHz Distance, m From 0.5 to From 0 to From 0.5 to From 20 to Interference MF intensity [db μv/m] 7
8 Output 8
9 Wiring Power supply voltage y (6 ± 0.72) V for transmitter with 0 5 (5 0) ma output y 5 2 V for transmitter with 20 (20 ) ma output, y power supply minimal voltage U PS is calculated as U PS = I MAX R L + U MIN, where R L overall load resistance, including control/measuring device, wire etc. I MAX maximal output (20 ma) U MIN 5 V, minimal voltage for transmitter without load. Power consumption of transmitter powered with 6 V: y. W for transmitter with 0 5 (5 0) ma output y 0.8 W for transmitter with 20 (20 ) ma output Explosion Protection Type, Output, Loop Type, and Load pressure level flow Explosion protection type Output, ma Loop type Load, Ω Without explosion protection Explosionproof Intrinsically safe or -wire RL UPS UMIN IMAX -wire 50 to wire Depends on safety barrier and/or power supply Male part for control unit connection Control buttons Z button Dot-matrix display Z button Electronic module of transmitter with handheld control unit Electronic module of transmitter with built-in control unit 9
10 Electronic module. General purpose and intrinsically safe type Transmitter with electrical connector Explosionproof type transmitters 26 6 Transmitters with dotmatrix display. Explosionproof type 0
11 Transmitter with cable entry Transmitter with electrical connector pressure level flow Four-Wire Loop Diagram (5-0 ma or -20 ma) Transmitter with cable entry Transmitter with electrical connector Two-Wire Loop Diagram (-20 ma)
12 Typical design of differential pressure transmitter Fixing screw for enclosure capy y y y Process flange gaskets 2 Enclosure cap with sight glassy y y y 5 Process flange nuts Electronic module O-Ringyy y y y 6 Cap for process connection port Control board with screwsy y y y 7 Process flange 5 Ribbon cabley y y y y y 8 Sealing screw 6 Grounding hole with bolt, gaskets and washer (external) 9 Drain / vent valve 7 Fixing screw for housingy y y y y 20 Process flange O-Ring 8 Electrical conduityy y y y y 2 Sensor module 9 Upper nameplateyy y y y y 22 Belt nameplate 0 Electronics housingy y y y y 2 Z button cover Grounding hole with bolt, gaskets and washer (internal) 2 Blank conduit 2 2 nutsy y y y y y y 25 Process flange screws Enclosure capy y 2
13 Weights Model Numbers Weight, kg, y no more than 700, 700, , 70, 750, 760, 770, 720, 720, 70, 70, 750, , 76, 77, , 720, , 725, , 7220, , 720, , 70, 7, 70, 7, 750, 75, , 750, 750, 7550 with DN , 750, 750, 7550 with DN , 752, 762, 722, 72, , 78, 758, 768, 728, 728, 78, 78, , 75, 755, 725, 725, 75, 75, to 5.0 * 757, to 8.0 * pressure level flow * Depends on the length of submersible part
14 Ordering information For better quotation processing please follow the specified options order. Separate options with -. Safir-M Explosion protection type (if required) Intrinsically Safe Explosionproof Model number (see Table 6-.) IS EP 5ХХХ Special requirements (optional) Extra burn-in 60 h Remote sealy y y Oxygen application (wetted parts code 02 only) (inert filling liquid, cleaned) Wetted parts materials code See Table 6-9 for details Attn.: check the availability fory y y y particular model number Ambient conditions code Temp. (+5 +50) C, humidity* 95± % at 5 Cy y Temp. (+5 +80) C, humidity* 95± % at 5 Cy y Temp. (-0 +50) C, humidity* 95± % at 5 Cy y Temp. (-0 +50) C, humidity* 95± % at 5 Cy y Temp. (-5 +80) C, humidity** 00 % at 5 Cy y y * condensation not permissible ** condensation permissible Reference accuracy code (see Table 6-5) Pressure ranges with units (see Table 6.. with notes) Static pressure in MPa (for model numbers 5xx and 55xx, see Table 6-2) Output signal code y0 5 may y y y y y y0 5 ma square rooty y y y y y5 0 may y y y y y y 20 may y y y y y y 20 ma square rooty y y y y y20 may y y y y y Control unit Built-iny y y y y y y y Handheldyy y y y y y y (omit option if not required) Mounting Kit Code (optional, see Table C-) Nominal Diameter DN (for model numbers 55xx and 5xx5) DN 50y y y y y y y y DN 80 XB RS OX 02 0, 0, 06,, 2 A Ax A2 A2x A 0,; 0,5; 0,25; 0,5 ХХХ ХХ BI HH Mxx D50 D80 Electrical Connector (if required) Not compatible with option -IS Upper Pressure Limit for the Model with Unit (ХХ) C
15 Code Diaphragm Material Stainless steel 2H8N0T Alloy 6NHTU Stainless steel 2H8N0T Hastelloy y C-276 2X8H0T Teflon-coated Titanium y alloy Titanium y alloy Wetted parts Material Stainless steel 2H8N0T Stainless steel 2H8N0T Stainless steel 2H8N0T Stainless steel 2H8N0T Stainless steel 2H8N0T Wetted parts materials Marking n/a O-Ring/ gasket material NBR or Fluoroelastomer SKF-26NM Fluoropolymer F Model numbers All except y 705, 75, 76, 77, 75,y 7x0, 7x0 7x0, 7x0 70, 70, 750, 7x5, 7x20, 7x, 75x0, 7xx8, 7xx, 7xx5 All except y 705, 75, 76, 77, 75,y 7x0, 7x0 7xx, 7xx5, 75x0 with remote seal 5 n/a 75, 76, 77, 75 Titanium alloy 62 n/a 75, 76, 77, 75 Notes:. Stainless still 2H8N0T in accordance with GOST (C < 0.2 %, Cr 7-9 %, Ni 9 %y Ti, Fe), equivalent to AISI 6L or AISI 0L. 2. Alloy 6NHTU in accordance with GOST (Ni 5-7 %, Cr.5- %, Ti %, y Al %, Fe %, Si, Mn), equivalent to Invar 6.. Hastelloy in accordance with EN Titanium alloy VT9 in accordance with GOST (Ni, Al %, Mo %, Zr %, Si %, Fe 0.25 %). 5. Fluoropolymer F (PTFE) in accordance with GOST pressure level flow 5
16 Model numbers 700, 700, , 70, 750, 760, , , 70, 750 Pressure type Model numbers Pressure ranges from to Min Span, kpa URL, kpa Absolute kpa 0 6 kpa kpa 0 00 kpa kpa 0.6 MPa Gage kpa 0 6 kpa kpa 0 00 kpa kpa 0.6 MPa MPa 0 25 MPa MPa 0 6 MPa Gage, kpa 0-6 kpa.6-6 negative kpa 0-00 kpa 0-00 Gage, kpa kpa.6.5 positive/ kpa kpa 0 00 negative kpa MPa Measuring unity diagram Electronic housing 2. Diaphragm type sensor y (silicon or silicon-on-sapphire). Inner cavity with filling liquid. Protective diaphragm 5. Process nipple 6. Cavity (vacuum for absolute pressure) 7. Measuring unit body 8. Gasket 9. Stop screw 0. Pressure port
17 L 5 Dimensions Model number 700, 700, , 70, 750, 760, 770, 720, 720, 70, 70, 750 L(max), mm pressure level flow 5 Ш6 M20Ч.5 Typical mounting and piping. Nut M20 2. Copper Gasket. Nipple Type. Connection Nut 5. Nut M8 6. Washer 8 7. Mounting Bracket Type 8. U-bolt See chapter Mounting kits for details 7
18 Model numbers 75, 76, Pressure type Model numbers Pressure ranges from to Min Span, kpa URL, kpa kpa 0.6 MPa Gage MPa 0 25 MPa MPa 0 00 MPa Gage, positive/ negative kpa MPa Measuring unity diagram 2. Electronic housing 2. Cavity (vacuum for absolute pressure). Cable gland. Diaphragm type sensor y (silicon-on-sapphire) 5. Pressure port 6. Process nipple 5 6 8
19 8 5 Dimensions Ш6 M20Ч.5 pressure level flow Typical mounting and piping. Nut M20 2. Copper Gasket. Nipple Type. Connection Nut 5. Nut M8 6. Washer 8 7. Mounting Bracket Type 8. U-bolt See chapter Mounting kits for details 9
20 Model number 772 Pressure ranges Pressure type Model numbers Min Span, MPa URL, MPa from to Gage MPa 0 00 MPa Measuring unity diagram Electronic housing 2. Diaphragm type sensor y (silicon-on-sapphire). Inner cavity with filling liquid. Flange 5. Protective diaphragm 6. Cavity (atmospheric pressure) 7. Body 8. Gasket 9. Bolts 0. Pressure port
21 207 Dimensions pressure level flow 5 5 Ш6 M20Ч.5 2
22 Model numbers 7, 75, 78, 7, 75, 78, 75, 755, 758, 76, 768, 72, 75, 78, 72, 725, 728, 7, 75, 78, 7, 75, 78, 75, 755, 758 Pressure ranges Pressure type Model numbers Min Span, kpa URL, kpa from to 7, 75, kpa 0 6 kpa.6 6 7, 75, kpa 0 00 kpa 0 00 Gage 75, 75, 755, kpa 0.6 MPa , 76, MPa 0 25 MPa Gage, negative Gage, positive/ negative Measuring unit diagram 72, 725, , 725, 728 7, 75, 78 7, 75, 78 75, 75, 755, kpa 0-6 kpa kpa 0-00 kpa kpa kpa kpa kpa kpa MPa xxx xxx5 xxx Р Р Р. Diaphragm type silicon sensor 2. Body. Inner cavity with filling liquid. Protective diaphragm 22
23 M20Ч.5 Dimensions DN D, mm D, mm n DN DN Model numbers Model numbers pressure level flow Model numbers M20Ч.5 2
24 Model numbers Pressure type Model numbers Pressure ranges from to Min Span, kpa URL, kpa Gage kpa 0 0. kpa Gage, negative kpa 0-0. kpa Gage, positive/ negative kpa kpa Measuring unity diagram Р Р atm Cable gland 2. Lever type sensor y (silicon-on-sapphire). Body. Protective diaphragm 5. Hard centre 6. O-ring 7. Flange 2
25 26 Dimensions ЧM8 2ЧNPTј pressure level flow 9 5 Typical mounting and piping. Connection Nut 2. Nipple Type. Gasket. Nipple M20x.5 2 See chapter Mounting kits for details 25
26 Model numbers Pressure type Model numbers Pressure ranges from to Min Span, kpa URL, kpa Gage kPa 0 kpa 0. Gage, negative kpa 0 - kpa 0. - Gage, positive/negative kpa -2 2 kpa 0. 2 Measuring unity diagram Р 2 Р atm Cable gland 2. Lever type sensor y (silicon-on-sapphire). Body. Protective diaphragm 5. Hard centre 6. O-ring 7. Flange 26
27 227 Dimensions ЧM8 NPTј pressure level flow 0 Typical mounting and piping. Bolt M0x 2. Washer 0. U-bolt. Mounting Bracket Type 5. Nut M8 6. Washer See chapter Mounting kits for details 27
28 Model numbers 75, , , 720 Pressure type Gage Gage, negative Gage, positive/ negative Model numbers Pressure ranges from to Min Span, kpa URL, kpa 75 0 kpa 0 0 kpa kpa 0 25 kpa kpa 0-0 kpa kpa 0-25 kpa kpa -5 5 kpa kpa kpa Measuring unity diagram Р 2 Р atm Cable gland 2. Diaphragm type sensor y (silicon or silicon-on-sapphire). Body. Protective diaphragm 5. Overpressure diaphragm 6. Flange 7. O-ring 28
29 205 Dimensions ЧM8 NPTј pressure level flow 2 0 Typical mounting and piping. Bolt M0x 2. Washer 0. U-bolt. Mounting Bracket Type 5. Nut M8 6. Washer See chapter Mounting kits for details 29
30 Model number 70 Pressure type Model numbers Pressure ranges from to Min Span, kpa URL, kpa Static pressure, MPa Differential kpa 0 kpa Measuring unity diagram Р Р 2. Cable gland 2. Lever type sensor y (silicon-on-sapphire). Body. Protective diaphragm 5. Hard centre 6. O-ring 7. Flange
31 26 Dimensions ЧM8 2ЧNPTј pressure level flow 9 5 Typical mounting and piping. U-bolt 2. Nut M8 with Washer 8. Mounting Bracket Type. Bolt M0x 5. Washer See chapter Mounting kits for details
32 Model number 70 Pressure type Model numbers Pressure ranges from to Min Span, kpa URL, kpa Static pressure, MPa Differential kpa 0 kpa Measuring unity diagram Р Р Cable gland 2. Lever type sensor y (silicon-on-sapphire). Body. Protective diaphragm 5. Hard centre 6. O-ring 7. Flange 2
33 20 Dimensions ЧM8 2ЧNPTј pressure level flow 5 Typical mounting and piping 7 8. Gasket Fluorine Rubber 2. Bolt M0x25 with Washer 0. -valve Manifold H-Type. Flange 5. Nipple Type 6. Bolt M0х0 7. Flange Adapter 8. Bolt M0х55 Note: Multiple parts are shown by sample See chapter Mounting kits for details
34 Model numbers 75, 720, 70, 7, 70, 7, 750, 75 Pressure type Differential Model numbers Pressure ranges from to Min Span, kpa URL, kpa Static pressure, MPa 75 0 kpa 0 0 kpa kpa 0 25 kpa kpa 0 6 kpa kpa 0 6 kpa kpa 0 00 kpa kpa 0 00 kpa kpa 0.6 MPa kpa 0.6 MPa Measuring unity diagram Р Р 2. Cable gland 2. Diaphragm type sensor y (silicon). Body. Protective diaphragm 5. Overpressure diaphragm 6. Flange 7. O-ring 5 6 7
35 20 Dimensions ЧM8 2ЧNPTј Model number 75, , 7, 70, 7, 750, 75 L(max), mm 5 pressure level flow L 5 Typical mounting and piping. Gasket Fluorine Rubber 2. -valve Manifold Coplanar. Flange with Nipple. Bolt M0х55 5. Copper Gasket 6. Nipple Type 2 7. Connection Nut Note: Multiple parts are shown by sample See chapter Mounting kits for details 5
36 Model number 76 Pressure type Model numbers Pressure ranges from to Min Span, kpa URL, kpa Static pressure, MPa Differential MPa 0 6 MPa Measuring unity diagram 2. Cable gland 2. Diaphragm type sensor y (silicon-on-sapphire). Body. Protective diaphragm 5. Flange 6. O-ring Р Р 5 6 6
37 205 Dimensions ЧM8 2ЧNPTј pressure level flow 5 5 Typical mounting and piping. -Valve H-type Manifold (assembled) 2. Nut M8. Washer 8. U-bolt 5. Bolt M8 with Washer 8 6. Mounting Bracket Type See chapter Mounting kits for details 7
38 Model numbers 7520, 750, 750, 7550 Pressure type Model numbers Pressure ranges from to Min Span, kpa URL, kpa Static pressure, MPa Hydrostatic kpa 0 25 kpa kpa 0 6 kpa kpa 0 00 kpa kpa 0.6 MPa Measuring unity diagram 2. Cable gland 2. Diaphragm type sensor y (silicon). Body. Protective diaphragm 5. Overpressure diaphragm 6. Flange 7. O-ring Р Р
39 D D D Dimensions 270 max 09 D D pressure level flow A NPTј 2ЧM8 nчш 8 DN50 DN80 D D D D D 90 A D 9 20 D n 8 5 Typical mounting 9
40 . Bolt M6 (recommended) 2. Vessel Flange. Gasket. Washer 6 5. Nut M6 2 5 See chapter Mounting kits for details Design with remote seal 80 nчш8 D Ш80 26 max D D D 2 2 А 2 A D D D2 D n DN DN о 5 о 0
41 Design with two remote seals pressure level flow
42
DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationST3000 Series 900 Smart Transmitter Differential Pressure Transmitters
No. SS2-STJ100-0100 (Rev.9) ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters Model STD910/STD920/STD930/STD960/STD921/STD931/STD961 OVERVIEW The ST3000 Smart Transmitter is a microprocessor-based
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/
More informationElectromagnetic Flowmeter
Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationPRODUCT CATALOGUE PREssURE switch
PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationHydraulic Pressure NAH Applications. Features. New generation available - refer to
NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for
More informationAT9000 Advanced Transmitter Differential Pressure Transmitters
No. SS2-GTX00D-0100 (Rev.8) AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance
More informationDIFFERENTIAL PRESSURE (FLOW) TRANSMITTER
DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER DATA SHEET FKC...5 The FCX AIII differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and
More informationFitting PS P - B - R2
INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationDifferential Pressure Transmitters
No. SS2-00D-0100 AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent
More informationPTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30
eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize
More informationTHM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist
THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,
More informationFKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications
FKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER The FCX AIII differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and transmits
More informationCALYS 80P. Field pressure calibrator with high accuracy 0.01%
Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS
More informationCoriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM
MAXIFO TM Features MaxiFlo Coriolis Mass Flowmeter series MCM is a mass flow meter that measures mass flow, density and temperature of liquids, slurries and gases. And it even measures oil content in water.
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationPascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure
DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully
More informationBTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters
FEATURES 5 mbar to 0 bar, 0. to 50 psi differential pressure...6 or...0 ma Precision temperature compensated and calibrated Rugged aluminium housing Female /8" BSP and /8" NPT fittings MEDIA COMPATIBILITY
More informationMasterpact. Installation recommendations
90 Installation recommendations Presentation Functions and characteristics 9 Dimensions and connection 5 Electrical diagrams 8 Operating conditions 92 Installation in switchboard 9 Door interlock catch
More informationGeneral Specifications
General Specifications Model EJB110 Differential Pressure Transmitter [Style: S2] The model EJB110 Differential Pressure Transmitter can be used to measure liquid, gas, or steam flow,
More informationApplication PN 16 / 40 DN Product features. Compact overall height Body shape gives optimum flow characteristic
pplication Control of gases, vapours and liquids. The modular concept of valve, multi spring actuator and digital FOXBORO/Eckardt positioner Type SRD 992 facililates trouble free expansion to allow for
More informationCALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%
ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX
More informationIndustrial Resistance Thermometers according to DIN Model MWD
Industrial Resistance Thermometers according to DIN measuring monitoring analysing MWD OMeasuring O range: -98... +600 ºC O O Pt00 sensor: class A, class B, class /3, class /0, or O O Output: resistance
More informationT20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en
T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More informationPressure. 1 Fitting PA R - N R2
INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More informationDS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch
DRUCK & TEMPERATUR LEITENBERGER GMBH DS 00 Electronic Pressure Switch Stainless Steel Sensor accuracy according to IEC 00: standard: 0. % FSO option: 0. % FSO Nominal pressure: from 0... 00 mbar up to
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationThe Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:
The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More informationS95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationDigital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5
Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More informationIBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationIntegral V-Cone Flowmeter VD series
TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing
More informationIBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationSINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol
SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.
More informationPG-200/PG-208 PRESSURE GAUGES P G G P P
Digital 3 1/2 digits monitor Set button for switch output HI or LO (PG-200) (PG-208) Digital 3 1/2 digits Power switch LO setting VR for switch output LO HI setting VR for switch output HI SPAN adjustment
More informationFLOW SENSOR FOR LIQUID MEDIA Serie 210
FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More informationMX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E
OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationLoad Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B
Force Load Washers for Forces of 7,5... 1 200 kn Type 9001A... 9071A 9081B, 9091B 1-component force sensor for measuring dynamic and quasistatic forces in z direction. F z Calibrated measuring range 100
More information4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)
.3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08 Introduction The HAH1BVW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications
More informationReflex-Radar BM 100 A
KROHNE 09/2001 7.02317.22.00 GR/PRINTO Reflex-Radar The universal TDR level gauge for liquids, solids and interface Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters
More information4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)
.2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof
More informationS95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, HART programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationSITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181
Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationDimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial
Incremental Encoder DRS/DRS, face mount flange up to 8,2 Dimensional drawing face mount flange radial Incremental Encoder Connector or cable outlet Protection class up to IP s TTL and HTL Zero-Pulse-Teach
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC5FW 500-S
AUTOMOTIE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY Introduction The HC5FW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications with
More informationMulti-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits
200 > Measurement and instrumentation Programmable digital transducers TRIAD 2 range Programmable digital transducers with to 4 analogue outputs Programmable accuracy class PRODUCT ADVANTAGES Up to 4 PROGRAMMABLE
More information4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure
.13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in
More informationMODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range
Liquid Inexpensive Microflow Coriolis Flowmeter CoriMate Ⅱ MODEL: CR002, CR003, CR004 GENERAL Based on the knowledge and experience on Coriolis technologies OVAL has gained over many years, the Corimate
More informationFlow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI
Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two
More informationSingle point load cells
SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC5FW 200-S/SP1
AUTOMOTIE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC5FW 200-S/SP1 Introduction The HC5FW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications
More informationEx-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments
.13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications
More informationContents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key
Contents dentification Type key Product data ntroduction Applications Features and benefits Performance range pole pole pole Construction Sectional drawing Construction features Test pressure Operating
More informationCV3000 Series. Characterized Insert Control Valves
CV3000 Series Characterized Insert Control Valves The CV3000 Series is a v-type control valve for precise control allowing high pressure drop capability with straight-through flow and bubble-tight shut
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More informationall stainless steel transducer multimedia compatibility
all stainless steel transducer multimedia compatibility High-Performance Silicon technology LARGE INVENTORY Fast Shipment! 0-0.07 to 0-690 bar 100 mv, 0 to 5 V, and 4 to 20 ma Outputs U 1, 2 & 5 psi Low
More informationtekcor TKC Multivariable Coriolis Flow Sensors
Sensing the pulse of industry Technical Data Sheet & General Specifications tekcor TKC Multivariable Coriolis Flow Sensors The tekcor TKC Series principle was initiated by tekflo sensors engineers, who
More informationHiPace 1200, with TC 1200, DN 200 CF-F
HiPace 1200, with TC 1200, DN 200 CF-F HiPace 1200, with TC 1200, DN 200 CF-F Similar Image Powerful turbopump with a pumping speed of up to 1250 l/s for N 2 DN 200 CF-F flange for demanding UHV applications
More informationLoad Washers. Force kn until kn. Type 9101A A
Force Load Washers 0... 20 kn until 0... 700 kn Type 9101A... 9107A Force sensor for measuring quasistatic and dynamic forces in industrial monitoring tasks. F z The force sensors are delivered uncalibrated
More informationEx-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)
Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including
More informationHYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC
HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF
More informationDifferential Pressure Switch
Features Using piezoresistive pressure sensor, which is compensated and aged well; high accuracy, quick response; Amplifier circuit driving switch relay; relay value could be set freely between zero and
More informationZ7A. Load cells. Special features. Data sheet. Wiring code
Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust
More informationP303 Pressure Regulator
P0 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges Integral Monitoring The BelGAS P0 and P0H gas pressure reducing regulators are available with a true monitor regulator,
More informationOperating instructions Pressure sensor PN / / 2007
Operating instructions Pressure sensor PN42 704298 / 00 0 / 2007 Contents afety instructions... 3 2 Function and features... 4 3 Function... 5 3. witching function... 5 4 Installation... 5 5 Electrical
More informationABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY
ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY www.abb.com/transformercomponents The information contained in this document is for general information
More informationFull Metal Variable Area Flow Meter and Counter
Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing Special versions up to 600 bar Measuring range: 10-100...00-000 L/h water 0.3-3.0...-0
More informationPG-100 HANDY MANOMETER COPAL ELECTRONICS FEATURES MODEL NUMBER DESIGNATION P G G P. marking Compatible with EMC directive
HANDY MANOMETER Power button Hold button marking Compatible with EMC directive Digital 3 1/2 digits Zero adjustment VR FEATURES Excellent stability State of the art sensor and circuit technology guarantees
More informationFlow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.
FVone-NP- 00/ (Push-in type) Recommended for: DN and bigger Required accessory: Threaded installation bush able type Optional accessory: PTFE sealing ring Locking set FVone-NP- 0/0 (Screw-in type) Recommended
More informationDRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach
NEW DRS : Incremental encoders, number of lines and zero pulse width freely programmable DRS : s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing
More informationField mounted Temperature Transmitter TF212/TF212-Ex
Data Sheet Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Input Resistance thermometer (,, -wire circuit) Thermocouples Resistance remote
More information