QC2030 2P 30A 120/240V Mini Breaker. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information
|
|
- Sharlene Copeland
- 5 years ago
- Views:
Transcription
1 4 South Street , TX Nacogdoches Phone: Fax: Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating connection interrupt rating Poles Trip Voltage Rating Dimensions and Weight Height Length Width Descriptions Description Long Description Product QC00 P 0A V Mini QC00 Quicklag Industrial Thermal-Magnetic Circuit, 0A, QC, Kaic, Two-Pole, Non-Interchangeable, V N/A Pole Din Rail Mount Circuit 0 W Cable-in/Cable-out kaic in Non-Interchangeable VAC 4 in.9 lb.8 in Manufacturer Information Brand GTIN Manufacturers Part Number QC00 UPC Taxonomies, Classifications, and Categories Category Description MOLDED CASE BREAKERS Quicklag Packaging Carton Weight Per each 0 Uses, Certifications, and Standards Application standard P 0A V MINI BREAKER Quicklag Industrial Thermal-Magnetic Circuit, 0A, QC type, kaic, Two-pole, Non-Interchangeable, V Quicklag Industrial Thermal-Magnetic Circuit Circuit Protection UL Listed; CSA Certified
2 Cutler-Hammer Technical Data Effective: April 998 Page Industrial Circuit s Description Curve No. Page QUICKLAG -Pole Circuit s, SC-0-77C QUICKLAG -Pole Circuit s, SC--77C QUICKLAG -Pole Circuit s, SC--77C 4 TD.9.0.T.E
3 Technical Data Page Effective: April 998 Industrial Circuit s Cutler-Hammer QUICKLAG -Pole Circuit s, - MINUTE HOUR HOURS,000, (- Amp) (-40 Amp) Single-Pole Trip Times at C➀ ,000 QUICKLAG -Pole Circuit s, - ambient, cold start. Connected with four (4) feet of rated wire (/7 C) per terminal. Tested in open air with current in all poles. -Pole QCGF, QCGFEP➂ QBGF, QBGFEP➂ QPGF, QPGFEP➂ QCHGF, QCHGFEP➂ QBHGF, QBHGFEP➂ QPHGF, QPHGFEP➂ QHPX, QHCX, HBAX ➁,000 Ac ( Hz),000 0, ➀ Single-pole test data at C based on NEMA procedures for verifying performance of molded case circuit breakers. ➁ For Special Low-Magnetic s. ➂ Time current curves show thermal-magnetic protection. GF protection has ma trip sensitivity. GFEP protection has 0ma trip sensitivity.,000, HOURS HOUR MINUTE Special Low-Magnetic -0A...0 Interrupting Time ,000,000,000 0,000 Curve No. SC-0-77C TD.9.0.T.E
4 Cutler-Hammer Industrial Circuit s Technical Data Effective: April 998 Page QUICKLAG -Pole Circuit s, - MINUTE HOUR HOURS,000, (- Amp) (-40 Amp) ,000 Single-Pole Trip Times at C➀ QUICKLAG -Pole Circuit s, - ambient, cold start. Connected with four (4) feet of rated wire (/7 C up to 0 amp, 7 C for amp) per terminal. Tested in open air with current in all poles. -Pole QCGF, QCGFEP➁ QBGF, QBGFEP➁ QPGF, QPGFEP➁ QCHGF, QCHGFEP➁ QBHGF, QBHGFEP➁ QPHGF, QPHGFEP➁ QHPX, QHCX, HBAX ,000 Ac ( Hz),000 0,000 or ➀ Single-pole test data at C based on NEMA procedures for verifying performance of molded case circuit breakers. ➁ Time current curves show thermal-magnetic protection. GF protection has ma trip sensitivity. GFEP protection has 0ma trip sensitivity.,000, HOURS HOUR MINUTE Interrupting Time ,000,000,000 0,000 Curve No. SC--77C TD.9.0.T.E
5 Technical Data Page 4 Effective: April 998 Industrial Circuit s Cutler-Hammer QUICKLAG -Pole Circuit s, -0 MINUTE HOUR HOURS,000, (-0 Amp) ,000 QUICKLAG -Pole Circuit s, -0 ambient, cold start. Connected with four (4) feet of rated wire (/7 C) per terminal. Tested in open air with current in all poles. -Pole Single-Pole Trip Times at C➀,000 Ac ( Hz) ,000 0, ➀ Single-pole test data at C based on NEMA procedures for verifying performance of molded case circuit breakers.,000, HOURS HOUR MINUTE (-40 Amp) Interrupting Time ,000,000,000 0,000 Curve No. SC--77C TD.9.0.T.E
QCD2030 Breaker-2P 30A 240V Din Rail. Features amperage rating circuit breaker type. Dimensions and Weight. Long Description
4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96--468 Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating circuit breaker type connection dimensions
More information6 INCH W X 5-3/4 INCH D X 8-3/8 INCH H
0 South Street -, TX Nacogdoches Phone: -- Fax: -0- S0N0AN.KVA PH 0/V /V Buck Boost Transformer Eaton Corp Catalog Number S0N0AN Manufacturer Eaton Corp Description Buck Boost Transformer, Power Rating
More informationSpecifications. Voltage Ratings: Interrupting Rating: Applications. Inverters Re-combiner boxes. LFJ 1000VDC Solar Series
0 VDC 125-4A Specifications Description The SPFJ series is the smallest 0VDC 125-4A photovoltaic fuse available in the market. The SPFJ series is manufactured in Class J case sizes that allows for both
More informationUL 1077 DIN Rail Supplementary Protectors
UL 0 DIN Rail Supplementary Protectors Product Overview UL 0 DIN Rail Supplementary Protectors PRODUCT OVERVIEW Product Overview Standard Features WMZS breaker terminals provide finger and back-of-hand
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationH i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f
H i g h A m p e r a g e 2 5 t o 3 0 0 A M P T y p e I & I I I V e h i c l e P r o t e c t i o n I P 6 7 W a t e r p r o o f I g n i t i o n - P r o t e c t e d S A E & A B Y C C o m p l i a n t L E D T
More information5SP and 5SY Supplementary Protection UL 1077
Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic
More informationSPF SERIES SOLAR FUSES
Vdc - A Specifications Voltage Rating VDC Amperage Rating,,,.,,,,, 0,,,,, Max. Interrupting Rating ka - A - A ka - A - A Time Constant ms Material Body: Melamine Caps: Copper Alloy Approvals UL - Listed
More informationBlocks and Holders POWR-BLOKS. Connectors. Ampere Ratings. Ordering Information. Applications. Specifications. Distribution/Splicer Blocks and Covers
Connectors Box lug connectors are designed for use with a single, solid or class B or C stranded conductor. Use of more than one conductor per connector opening or use of extra-flexible, fine stranded
More informationX T O B P 1 6 B C 1 S
9 Overload Relays XTOB, XTOT May 07 Contents Description Page Overload Relays XTOB, XTOT Selection................ 9 Product Selection.......... 95 Accessories............... 9 Technical Data and Specifications............
More informationKLKd Series 10x38 FUSES
KLKd Series 0x FUSES 0 VAC 0 VDC /0- A Fast Acting Description The KLKD fuse series is fast-acting with a high DC voltage rating. This family of Midget style fuses (0 x mm) is used in solar combiner boxes
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationC60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka
C0N circuit breakers0 B, C and s IEC 0898: 000 A, IEC 097-: 0 ka Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of
More information08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics
0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationMCB NB1-63H Miniature Circuit Breaker
NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationCDB6a. Standard: IEC IEC Trip Curve: B, C and D curves Breaking Capacity: 3000A. Technical data. Rate current
CDBa Standard: IEC 09- IEC 097- Breaking Capacity: 000A Function CDBa miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits
More informationNABCEP Entry Level Exam Review Solfest practice test by Sean White
1. A fall protection system must be in place for all work done at heights in excess of a. 4 feet b. 6 feet c. 8 feet d. 10 feet 2. A circuit breaker performs the same function a. as a fuse b. as a switch
More information3VT4 Molded Case Circuit Breakers up to 1000 A
VT4 Molded Case Circuit Breakers up to 00 A Catalog Technical nformation VT4 Molded Case Circuit Breakers up to 00 A General data / - Overview Circuit breakers Switch disconnectors / - Selection and ordering
More informationTeSys circuit-breakers
Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the
More informationLEDlight 20 W Universal dimmable series
LEDlight 20 W Universal dimmable series L05011i2 / L05011i3 / L05011i4 Lumotech technology Lumotech LED drivers are designed to efficiently power and control LED solutions for general lighting applications.
More informationGeneral characteristics, Products
The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationNH fuse-links gg 500VAC double indicator/live tags size 000, 00, 0, 1, 2, 3
NH fuse-links gg VAC IEC NH Fuse-Links The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade
More information440V 500V V / / /2 12.
-26 Manual Motor Protectors March 0 B-Frame D-Frame Table -6. XTPR Rotary Manual Motor Protectors with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective
More informationTHE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE
July 04 THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE In this third part. we want to speak about how important is the correct sizing of the
More information400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL
400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. July 2013 REV. 015 2013 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix AP Harmonic
More informationSIRCOVER Manual transfer switches from 125 to 3200 A
Manual transfer switches svr_149_a 3200 A Function are manual multipolar transfer switches with positive break indication. The family includes two ranges: AC for dead time switching (I-0-II), for overlapping
More informationSealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards
Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.
More informationSiemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.
Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit
More informationIssued August DATA SHEET. 3VT5 MCCB up to 1600 A
ssued August 9 DATA SHEET VT5 MCCB up to 0 A Based on Siemens Catalog V 8 Standard circuit breakers Releases Technical specifications Specifications VT5 circuit breakers Switch disconnectors Type Standards
More informationBETA Protecting Miniature Circuit Breakers
Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional
More informationLEDlight 30 W Universal dimmable series
LEDlight 30 W Universal dimmable series L05031 Lumotech technology Lumotech LED drivers are designed to efficiently power and control LED solutions for general lighting applications. System reliability
More informationBETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008
LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationSemiconductor (AC) fuses
BS88 Fuses x1, 17x9, X17x9, 6 VAC EXTREMELY HIGH BREAKING CAPACITY FUSES: PROTECTION OF POWER SEMICONDUCTORS AS PER IEC STANDARD 6069.1 AND 6 V VOLTAGE RATING COMPLYING WITH IEC GR CLASS (RATINGS FROM
More informationA new set of standards
A new set of standards Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for T8 lighting fixtures Philips Advance Optanium high-efficiency electronic ballasts are
More informationIssued August DATA SHEET. 3VT3 MCCB up to 630 A
ssued August 9 DATA SHEET VT MCCB up to 6 A Based on Siemens Catalog V 6 8 Circuit breakers Switch disconnectors Technical specifications Specifications Type VT 76-AA6/6/56-AA, VT 76-AA6/6/56-AA Circuit
More informationSingle Phase Motors Technical Datasheets
Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and
More informationfür for T5-Lampen fluorescent in Multi-Lamp-Technologie
Dimmbare Dimmable electronic elektronische control Vorschaltgeräte gear für for T-ampen fluorescent in Multi-amp-Technologie lamps in technology M-tec Performance characteristics Dimmable ECG in Multi-amp
More information90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION
MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230/400-240/415
More informationTeSys DF IEC-Type Fuseholders
TeSys DF IEC-Type 9080CT080 08 Contents... Page Characteristics......3 Accessories... Dimensions...5 Wirg diagrams...5 Fuses...6 7 Characteristics TeSys DF IEC-Type Fuseholder type DF8 DF0 DF DF DFCC Environment
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights Street Side House Side 2 1 0 1 1 5 2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 8 foot mounting height. 7 3/4 1 3/4 3 1/8.02 0 3 1/2.01.005
More informationFilm Capacitors. EMI suppression capacitors. Date: June 2018
Film Capacitors EMI suppression capacitors Date: June 2018 EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without
More informationATyS Automatic and remotely operated transfer switches from 125 to 3200 A
atys-p_001_b atys_d_001_a_1_cat ATyS p I-0-II 4P ATyS d I-0-II 4P Function The ATyS are three-phase motorised transfer switches with positive break indication. They enable the on load transfer of two three-phase
More informationEaton s Arrow Hart Controlled receptacles. Control marked receptacles are the ideal solution for minimizing energy usage.
Eaton s Arrow Hart Controlled receptacles Control marked receptacles are the ideal solution for minimizing energy usage Arrow Hart Controlled receptacles Dual and half s Product description 2-pole, 3-wire
More information90 MCB range Modular circuit breakers for circuit protection
MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230 / 400
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights Street Side House Side INDEPENDENT TESTING LABORATORIES, INC. 2 1 0 1.05.1 1.5 2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 20 foot
More information30Vdc Series ELECTRICAL CHARACTERISTICS
RLD P UF Series Devices 2009.10.07 The Radial Leaded devices (RLD Series), a polymer-based Positive Temperature Coefficient (PTC) device to protect electrical circuits against over-current conditions with
More informationBMXART0814 analog input module M340-8 inputs - temperature
Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Product availability : Stock - Normally stocked in distribution facility Price* : 1485.00 USD Main Range of
More informationISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER
ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection
More informationAmerican Zettler AZ742 RELAY Datasheet
American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More informationMetallized Polypropylene Film Capacitor Related Document: IEC
MKP 184 Metallized Polypropylene Film Capacitor Related Document: IEC 6084-16 MAIN APPLICATIONS: High voltage, high current and high pulse operations, deflection circuits in TV sets (S-correction and fly-back
More informationPOWER FACTOR CORRECTION CAPACITOR CELLS SPECIFICATIONS
SPECIFICATIONS DESCRIPTION Metallized polypropylene capacitors offer improved performance and proven reliability in applications requiring power factor correction or harmonic filtering. Metallized polypropylene
More informationSFRV Polymer PTC Thermistor SFRV ROHS
Polymer PTC Thermistor ROHS Features High voltage endurance. Designed for telecom applications. Low parasitic capacitance, flat impedance with frequency. RoHS compliant and UL certificate(file No.:E305346).
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationDIN Timers TD. Options and ordering codes. Specification
DIN imers D 17.5mm or 22.5mm DIN rail mounting Electronic imers Wide coil operation, 24V to 320V AC/DC Multi ime range / Multi function ON-Delay, OFF-Delay, Asymetrical, Star/Delta versions Perfect to
More informationISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER
ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More information14.05 (356,9) (344,2) 2.60 (66,0) 3.00 (76,2) STATUS LED
RACKS Channel FEATURES For use with Style Controllers Available for Standard, Miniature, G and OpenLine Modules Panel and DIN Rail Mount Versions UL, CSA Certified CHANNEL RACK: Standard Part No. 0RCK
More information0T 0TS S T TS T TS T TS 0T T T T T T 6T T TS 6T 6TS T TS 6T 6TS 6T 6TS 6T 6TS Frame.. 6. 6 6... 6.... B 6 6... A..... 0..0... 6.... 6.....06 6.66.. 6.0.....6 0... C 6..0 6. 6....... E.. D....... F 6............
More informationMICROTEMP Thermal Fuses: Introduction
Introduction G4 G5 G7 Therm-O-Disc is a world leader in chemical pellet style thermal fuses. Microtemp Thermal Fuses are available in a variety of standard and custom configurations, providing reliable
More informationTable of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP
Table of Contents -Configuration Selection Guide for HDE, HDS, & EFP Service Voltage Rating... Electrical Service Ratings... Ampacity Ratings by Contact... Electrical Service Ratings Explained... Operating
More informationElectrical Test Report on PS3300 Series Uninterruptible Power Supply for Powerstar Inc. Gaithersburg MD
Test Report No. 10746.1 No. of Pages 88 Electrical Test Report on PS3300 Series Uninterruptible Power Supply for Powerstar Inc. Gaithersburg MD Prepared by NU Laboratories, Inc. 312 Old Allerton Road,
More informationInterference Suppression PCX2 337 film capacitors
MKP RADIAL POTTED CAPACITORS Pitch 10.0/15.0/22.5/27.5mm QUICK REFERENCE DATA Capacitance range (E6 series) * 0.01to 3.3 Capacitance tolerance 10 %, 20 % Rated (AC) voltage 50 to 60 Hz 275 V ~ Climatic
More informationGeneral Purpose Relays Types K, R, N, and C
General Purpose Relays s K, R, N, and C Catalog 0 Class 0 CONTENTS Description Page R Miniature Plug-in Relays..................................... K Plug-in Relays.............................................
More informationP E R S O N A L L I G H T I N G S Y S T E M
ld3 W D E S K L A M P P E R S O N A L L I G H T I N G S Y S T E M All measurements in footcandles based on the distance between the lamp head to the desk surface at 10, 12 and 14. 11 17 10-42 12-34 14-27
More informationBMXART0814 analog input module M340-8 inputs - temperature
Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Main Range of product Product or component type Electrical connection Input output isolation Input level Analogue
More informationNon-Fused. Series DS2 IEC Non-Fused 12 Disconnect Switches. Accessories 15. Specifications 16. Dimensions 17. See Enclosed Disconnects 21
s e r i e s c3controls offers the most rugged, dependable Disconnect Switches that money can buy. From Panel/Base Mount to Door Mount with switch ratings from 16A - 125A, we ve got what you need. And,
More informationThermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction
Thermal-Magnetic / Magnetic Only Molded ase ircuit reakers Introduction Table 8: reakdown of Typical atalog Number L 3 6 0 V 2 reaker amily Y - mpere rame - mpere rame K - 2 mpere rame L - mpere rame M
More informationEXEMPLAR NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 ( ) (X-Paper) 09:00 12:00
NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 2008 (12041002) (X-Paper) 09:00 12:00 EXEMPLAR This question paper consists of 7 pages. EXEMPLAR -2- NC(V) TIME: 3 HOURS
More informationPRODUCT SPECIFICATIONS
FEATURES AND BENEFITS* Up to 14 year DC life 56V DC working voltage Resistive cell balancing Overvoltage outputs High power density 4U, half-rack package UL registered TYPICAL APPLICATIONS UPS systems
More informationRedline Unibis : the solution Circuit protection
2 circuits in 1 mo Redline Unibis : the solution ircuit protection Unibis compact Ms are one of the latest introductions in the Redline range and are developed to reduce the size of the distribution board
More informationNumber of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E
The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of 0,000 V. and
More informationSemiconductor (AC) fuses
gr 690 VAC sizes 000 to (full range) Ferraz Shawmut PROTISTOR NH grb 690 VAC fuselinks provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More information2.3. Rockers. Contents
. SVRSealed Vehicle SVRSealed Vehicle Rocker Contents Description SVRSealed Vehicle Above Panel Rocker Switch............... Below Panel Rocker Switch............... Technical Data and Specifications..........
More informationNEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology
Clean Water through Innovative Technology NEW!! Instrument Overview Reliable Chlorine Monitoring HF scientific developed the OnLine Residual Chlorine Monitor specifically for drinking water, wastewater
More informationThermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction
Thermal-Magnetic / Magnetic Only Molded ase ircuit reakers Introduction Table 8: reakdown of Typical atalog Number L 6 0 V reaker amily Y - mpere rame - 0 mpere rame K - 0 mpere rame L - mpere rame M 00
More informationSemiconductor (AC) fuses
Main characteristics 6,9 grb 7 PA 6,9 grb 73 TTF 000 + MS7V-5 UR Ferraz Shawmut PSC-gRB 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion
More informationEMI Suppression PCRC 420 film capacitors (RC unit)
MKP RADIAL POTTED CAPACITORS Pitch 15.0/17.5 mm P = 15.0 / 17.5mm QUICK REFERENCE DATA Capacitance value Capacitance tolerance Resistance value Resistance tolerance Rated (AC) voltage 50 to 60 Hz Climatic
More informationPTS Volt DC surface mount resettable PTC devices. Technical Data Applications. Agency information.
Supersedes August 2014 Pb HALOGEN HF FREE Applications USB Peripherals Disk drives Power tools Rechargeable battery pack protection Plug and play protection for motherboards and peripherals Mobile phones
More informationTeSys enclosed starters 2
Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,
More informationThree-Terminal Low Current Positive Voltage Regulators BL78XX
FEATURES Internal Thermal Overload Protection. Internal Short Circuit Current Limiting. Output Current up to 1.5A. Satisfies IEC-65 Specification. (International Electronical Commission). MSL 3 Pb Lead-free
More informationPRODUCT SPECIFICATIONS
FEATURES AND BENEFITS* Up to 1,000,000 duty cycles or 10 year DC life 48V DC working voltage Active cell balancing Temperature output Overvoltage outputs available High power density TYPICAL APPLICATIONS
More informationMetallized polypropylene film AC motor capacitor
Datasheet ENGLISH Metallized polypropylene film AC motor capacitor RS Product List: Item Description 843-2014 Motor cap 4uF AMP187 843-2020 Motor cap 2.5uF 350V tinned wire 3.8mm 843-2023 Motor cap 3uF
More informationDATA RACK BUSBAR. Data Rack Busbar Systems A.
Data Rack Busbar Systems 250...1000 A www.eae.com.tr Overview Overview To power the mission critical IT infrastructures on the Data Rack Cabinets, EAE offers a highly flexible and reliable Busbar System
More informationOnline data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS
Online data sheet WL80-S30 W80 WL80-S30 W80 A B C D E F Illustration may differ Ordering information Type Part no. WL80-S30 607484 Included in delivery: P0 (), BEF-W80 () Other models and accessories www.sick.com/w80
More informationProject. Project Location. Catalog #
Location Catalog # A. Description Aris is a low-profile luminaire that is ideal for undercabinet, task and display case lighting in both residential and commercial applications. Its 0." high x." cross-section
More informationSingle Phase Motors Technical Datasheets
Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and
More informationR.46. X2 CLASS (IEC ) - MKP Series SELF-HEALING PROPERTIES 09/
Loose Taped X CLASS (IEC 60384-4) - MKP Series Typical applications: interference suppression and «across-the-line» applications. Suitable for use in situations where failure of the capacitor would not
More informationProduct datasheet QT 2X26 42/ S. QUICKTRONIC MULTIWATT ECG for CFL. QT 2X26 42/ S Page 1 of 16
QT 2X26 42/220 240 S QUICKTRONIC MULTIWATT ECG for CFL QT 2X26 42/220 240 S Page 1 of 16 Technical data Electrical data Line current Nominal voltage Mains frequency DC voltage 0.39 A 220 240 V 50 60 Hz
More informationEmergency lighting units EM Inverter
T T TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM G, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps ow-profile casing
More information