ROC7080: RADIATION THERAPY PHYSICS LABORATORY LAB A : MECHANICAL MEASUREMENTS LINAC QA

Size: px
Start display at page:

Download "ROC7080: RADIATION THERAPY PHYSICS LABORATORY LAB A : MECHANICAL MEASUREMENTS LINAC QA"

Transcription

1 ROC7080: RADIATION THERAPY PHYSICS LABORATORY LAB A : MECHANICAL MEASUREMENTS LINAC QA GROUP I SPRING 2014 KEVIN JORDAN GRADUATE STUDENT, RADIOLOGICAL PHYSICS KARMANOS CANCER CENTER WAYNE STATE UNIVERSITY

2 Table of Contents I. Introduction... 3 II. Laboratory Procedures & Methods... 3 III. Questions & Discussion... 3 IV. Appendix C: References... 9 JORDAN,KEVIN 2

3 I. Introduction In this laboratory, the uses and mechanisms of determining LINAC quality assurance measurements have been explored. The proceeding sections can be found to include Laboratory Procedures & Methods, Questions & Discussion along with the appendices, which include the experimental data, sample calculations and references. II. Laboratory Procedures & Methods This laboratory allowed the group to gain experience in light field and radiation field alignment, collimator/table/gantry isocentricity, laser alignment, optical distance indicator accuracy, light field & digital readout field size agreement and block tray alignment all to ensure the accuracy of the LINAC mechanical setup and gain experience in the quality assurance process. Questions and discussion given the exercises demonstrated in the lab can be found in the proceeding section. III. Questions & Discussion 1. How does one adjust the position of the light field so that it matches the radiation field? How does one adjust the size of the light field to match the radiation field? Recall, the light field is supposed to represent the area to be irradiated by the x-ray beam. This means that the center of the light field and x-ray field should coincide. Because of how the light is projected, it can be affected by the position of the light bulb, the bulb type, along with the position and angle of the mirror. One may need to keep in mind the beam steering and positioning if the radiation field deviated significantly to one side or overall on the film, keeping in mind the positioning of the bending magnet as well. A nice pictorial representation of this can be seen below. JORDAN,KEVIN 3

4 2. How could you use the two films taken at 5 and 10 MU to quantitatively check the light field size vs. radiation field size? One could take these two films and analyze their optical density, by using a scanning densitometer, in order to determine the true edge of the radiation field. It is difficult for the blind eye to determine the 50% line, so thus it is best to utilize the scanning densitometer to verify this most accurately. Recall, we truly applied 100 MU at two different energies, 6MV and 10MV photons. 3. How did the check of collimator isocentricity done with the star shot compare with that done using the light field? Estimate the uncertainty of the methods. The star shot is certainly more precise and accurate, as it represents a static hold on the radiation that was seen during the beam on time. The Light field method is more of a quick and dirty method, providing some level of accuracy, based on the crosshairs put in the middle of field and then measuring deviation about certain angles along the axis of rotation. Recall, the light field was based of a ruler measurement with 1 mm resolution and thus +/- 0.5 mm uncertainty. The manual scanning densitometer manual states that it has an uncertainty of +/- 0.02D. Since we did not have the film scanned it is hard to speculate on comparative uncertainties, but these values can be used for respective analyses. JORDAN,KEVIN 4

5 4. If a physicist found that the collimator star shot were perfect, but the crosshair shadow moved in a circle when the collimator rotated, what could be in need of adjustment? One might need to look at the angle of the mirror for the light field or the possibility that the entire collimator head itself is slightly out of plane. If either of these, or both, were not level and true with the table surface, it would cause a shadow that would then rotate with the collimator as it rotated. 5. How did the check of gantry isocentricity done with the star shot compare with that done using the light field? Estimate the uncertainty of the methods. Recall how the film was held upright in the phantoms, perpendicular to the axis of rotation, as the gantry rotated around this setup. Again, it seems that the uncertainty of the methods again can be quantified by the scanning densitometer, +/- 0.02D and then the ruler resolution of 1mm and thus an uncertainty of +/- 0.5 mm. Also, we used the front pointer to rotate about the isocenter. All of these methods suggested no more than a 0.5 mm deviations +/- 0.5 mm, thus meeting the required gantry tolerance standards. 6. What are the limitations of star shots? Can star shots determine deviations in all three dimensions? Are there any considerations about using star shots with asymmetric jaws? One can intuitively determine that, like film, star shots are 2D and thus can only be used for one plane at a time. Star shots cannot determine 3D distribution; another setup for an additional plane would have to be done. Asymmetry offers something unique in that the light and radiation distribution will be located at different portions along the film, and not necessarily at isocenter, TG-50 provides some nice instructions on this and MLC s in general. So the rotation about a circle at the center may not be viable for this given asymmetry. Recall at the end of the laboratory we were able to conduct both the picket fence and interdigitation tests, showing these respective results on film, one could analyze with a scanning densitometer the results of the picket fence, for example, and verify the optical density consistency within each fence post where the collimators were opened and adjusted with the beam on for the same field size at each fence post. JORDAN,KEVIN 5

6 7. Routine weekly or monthly quality assurance tests are often made with the light field, rather than by shooting star shots. Are there any requirements on the order in which these checks are made? While conducting this laboratory, we all assisted the instructor with the monthly QA. The specification sheet has in order: review of daily QA, front pointer calibration, laser alignment, treatment couch positioning, wedge/electron cone, and then field light intensity. Additionally, the data should be recorded as: symmetric jaws, asymmetric jaws, digital angle indicators, optical distance indicators, isocentricity. It seems intuitive to have these prescribed orders as they provide for a lock step and linear method for achieving the end isocentricity. One may have to repeat certain steps if they overall broad picture of the QA process was not addressed and then getting more specific, somewhat of a hierarchy and logical flow chart to provide for timely and most accurate end results of the LINAC QA. 8. How does the isocentricity of this linear accelerator compare to recommended standards? Overall, one desires to meet no more than 1 mm deviation between the gantry, collimator and couch. From our best estimations using the tools used, it seemed that the deviation of the gantry, collimator and couch deviated no more than 0.5 mm +/- 0.5 mm, and thus met the recommended standards. 9. During an acceptance test, what additional tests of light field/radiation field alignment would you recommend? There are some additional mechanical system tests worth mentioning. These would include verifying the patient support system and also the beam modifier systems, including the electron applicators, as deviations with these items also change the nominal field and radiation sizes and these are complimentary tests to be done while doing the other acceptance tests. This laboratory conducted an assessment of the alignment of the collimator axis and collimator jaws. The adjustable collimator jaws, when closed, must maintain symmetry about the collimator assembly axis while being rotated. A mechanical front pointer grasped by the jaws can be used and then extended from isocenter. Consequently, the rotation of the collimators will allow the front pointer to trace out any misalignment on a sheet of paper any misalignment between the collimator axis and the jaw faces. Additionally, the light field and radiation field congruence and coincidence should be checked. JORDAN,KEVIN 6

7 10. How would you verify that the lasers were properly aligned at points away from isocenter? One could use a rudimentary method of using a piece of paper and yardstick at different locations along the beam to determine the alignment. The values should be consistent along this path. Recall, that the laser alignment should be within 2 mm, as talked about in question During an acceptance test, what additional tests of optical distance indicator accuracy would you recommend? Some additional testing in reference to the optical distance indicator accuracy might include both manual and automatic tooling for verifying readout values with that of ones recorded during the acceptance test. For example an electronic tape measure and a level may be used for comparing distance and angles respectively at different points along the couch, gantry angle, collimator rotation angle to have a double redundant immediate and accurate values for the machine upon acceptance. 12. How closely did the indicated field size agree with the measured? What is the uncertainty of the measurement? What would be the maximum allowable deviation? All in all, the field sizes were all off by about 1mm, so 10 x 10 cm 2 field size was approximately 10.1 x 10.1 cm 2, thus presenting a 1% error/side (10.1/10 = 1.01 = 1%). The ruler which was used for the measurement had a resolution of 1 mm, and thus the uncertainty was +/- 0.5 mm. The maximum allowable deviation is 2 mm, as prescribed by TG How frequently, and by whom, the following items should be checked: Laser Alignment Daily, 2mm tolerance Gantry Isocentricity Annual, 2mm diameter circle tolerance Light/X-ray alignment Monthly, 2mm or 1% on a side tolerance ODI accuracy - Daily, 2mm tolerance Tray alignment Monthly, 2mm tolerance These frequencies and tolerances can all be found on pp. 12 of Report 46, for TG- 40. All these items should be verified by the physicist, even if someone else like the field service engineer did some of these checks already. JORDAN,KEVIN 7

8 14. In this lab you check several mechanical alignments individually. Many such alignments affect the accuracy of patient treatments. Think about the process that a patient is taken through to prepare and deliver a treatment consisting of two parallel- opposed fields (i.e. simulation, block preparation, and treatment). Assume the patient is simulated AP and is to be treated with an AP: PA pair. List as many mechanical parameters as you can think of which could affect the ultimate location of one edge of the PA field. If each were held to a tolerance of 2 mm, and if the errors were distributed randomly, what would be the average error? What would be the maximum error if no misalignments canceled? Can you suggest a test which would check the overall accuracy of the treatment delivery system? So there are many variables that can add up to be a potentially unfavorable tolerance stack up. First off, the patient was simulated AP, the PA side could easily have differentiation and asymmetry from the AP side. Additionally, the makeup of this tissue could be slightly different as well, but that is another discussion. The simulation environment versus the treatment day may have been different as well. The couch sag, respiratory gating and bladder retention all will vary to an extent, hopefully recognized by the TPS upon setup during time of treatment. One could hopefully assume that if the errors were distributed randomly that they would cancel out; so +2mm on tolerance, say the couch and another tolerance of -2 mm, say on the patient bolus profile, negated this, then the average error would be zero ( / 2 = 0), but with an uncertainty based upon the measurement device. Let one assume this to be 1mm resolution again, therefore an uncertainty of +/- 0.5 mm/variable. Recall, that the root sum square method can be used for quantifying the cumulative uncertainty. Cumulative Uncertainty Quantification (RSS) = Uncertainties! Fiducials would be a likely candidate for usage to ensure the accuracy of the tumor location, minimizing the issue with the peripheral mass of the person and the setup differences. Treatment delivery based on the simulation would then be validated by the true locations of these fiducials for current and future, realtime alignment. JORDAN,KEVIN 8

9 IV. Appendix C: References TG-40 TG-45 TG-142 Burmeister, Jay. Radiation Dosimetry Coursepack Rakowski, Joe. Radiation Therapy Physics Course Notes JORDAN,KEVIN 9

ROC7080: RADIATION THERAPY PHYSICS LABORATORY LAB TWO : THERMO LUMINESCENT DOSIMETRY

ROC7080: RADIATION THERAPY PHYSICS LABORATORY LAB TWO : THERMO LUMINESCENT DOSIMETRY ROC7080: RADIATION THERAPY PHYSICS LABORATORY LAB TWO : THERMO LUMINESCENT DOSIMETRY GROUP I SPRING 2014 KEVIN JORDAN GRADUATE STUDENT, RADIOLOGICAL PHYSICS KARMANOS CANCER CENTER WAYNE STATE UNIVERSITY

More information

Nuclear Associates

Nuclear Associates Nuclear Associates 37-001 TEL-ALIGN Teletherapy Alignment Gauge Users Manual March 2005 Manual No. 37-001-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names

More information

Chapter 10 Acceptance Tests and Commissioning Measurements

Chapter 10 Acceptance Tests and Commissioning Measurements Chapter 10 Acceptance Tests and Commissioning Measurements This set of 189 slides is based on Chapter 10 authored by J. L. Horton of the IAEA publication (ISBN 92-0-107304-6): Radiation Oncology Physics:

More information

Evaluation of the truebeam machine performance check (MPC): mechanical and collimation checks

Evaluation of the truebeam machine performance check (MPC): mechanical and collimation checks Received: 5 December 2016 Revised: 30 January 2017 Accepted: 14 February 2017 DOI: 10.1002/acm2.12072 RADIATION ONCOLOGY PHYSICS Evaluation of the truebeam machine performance check (MPC): mechanical and

More information

Simulation Modeling in Dosimetry

Simulation Modeling in Dosimetry Simulation Modeling in Dosimetry Aleksei Zhdanov Ural Federal University named after the first President of Russia B. N. Yeltsin, Yekaterinburg, Russian Federation jjj1994@yandex.ru Leonid Dorosinskiy

More information

Monitor Unit Calculations for Photon and Electrons. AAMD Meeting Raleigh, NC October 3, John P. Gibbons Chief of Clinical Physics

Monitor Unit Calculations for Photon and Electrons. AAMD Meeting Raleigh, NC October 3, John P. Gibbons Chief of Clinical Physics Monitor Unit Calculations for Photon and Electrons AAMD Meeting Raleigh, NC October 3, 2014 John P. Gibbons Chief of Clinical Physics Outline I. TG71 Formation and Charge II. Photon Calculations III. Electron

More information

x Builders Level Service Manual

x Builders Level Service Manual 40-690 22x Builders Level Service Manual Item Description Pages.0 Overall Instrument Assembly 2. Main Assembly 2.2 Telescope Assembly 3.3 Base Assembly 4.4 Frame Assembly 5 2.0 Calibration 6-8 2. Vial

More information

Instrumental Quality Control of Therapeutic Linear Accelerator Performance

Instrumental Quality Control of Therapeutic Linear Accelerator Performance American Journal of Physics and Applications 2017; 5(5): 66-72 http://www.sciencepublishinggroup.com/j/ajpa doi: 10.11648/j.ajpa.20170505.12 ISSN: 2330-4286 (Print); ISSN: 2330-4308 (Online) Instrumental

More information

1.1.4 What are the differences between the Varian 600C and the Siemens KD2?

1.1.4 What are the differences between the Varian 600C and the Siemens KD2? 1 Radiotherapy 1.1 Linear Accelerators 1.1.1 Sketch the main components of a linear accelerator. 1.1.2 Describe the theory of beam production and the part each component plays in the production of a clincally

More information

Objectives. Tolerance Limits and Action Levels for IMRT QA. The Overall Process of IMRT Planning and Delivery. Chain of IMRT Process

Objectives. Tolerance Limits and Action Levels for IMRT QA. The Overall Process of IMRT Planning and Delivery. Chain of IMRT Process Tolerance Limits and Action Levels for IMRT QA Jatinder R Palta, Ph.D Siyong Kim, Ph.D. Department of Radiation Oncology University of Florida Gainesville, Florida Objectives Describe the uncertainties

More information

Double-Slit Interference

Double-Slit Interference Double-Slit Interference 1. Objectives. The objective of this laboratory is to verify the double-slit interference relationship. 2. Theory. a. When monochromatic, coherent light is incident upon a double

More information

Time-resolved beam symmetry measurement for VMAT commissioning and quality assurance

Time-resolved beam symmetry measurement for VMAT commissioning and quality assurance JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 2, 2016 Time-resolved beam symmetry measurement for VMAT commissioning and quality assurance Michael P. Barnes 1,2 a and Peter B. Greer 1,3

More information

Reference Dosimetry for Megavoltage Therapy Beams: Electrons

Reference Dosimetry for Megavoltage Therapy Beams: Electrons Reference Dosimetry for Megavoltage Therapy Beams: Electrons David Followill Ph.D Radiological Physics Center UT M.D.Anderson Cancer Center Houston TX Protocol for Clinical Reference Dosimetry of High-Energy

More information

ASSESSING LEAKAGE WORKLOADS OF MEDICAL LINEAR ACCELERATORS FOR IMRT AND TBI TECHNIQUES

ASSESSING LEAKAGE WORKLOADS OF MEDICAL LINEAR ACCELERATORS FOR IMRT AND TBI TECHNIQUES ASSESSING LEAKAGE WORKLOADS OF MEDICAL LINEAR ACCELERATORS FOR AND TBI TECHNIQUES A Thesis submitted to the Faculty of the Graduate School of Arts and Sciences of Georgetown University in partial fulfillment

More information

The volume effect of detectors in the dosimetry of small fields used in IMRT

The volume effect of detectors in the dosimetry of small fields used in IMRT The volume effect of detectors in the dosimetry of small fields used in IMRT Wolfram U. Laub a) Department of Medical Physics, University of Tübingen, Germany Tony Wong b) Department of Radiation Oncology,

More information

ELECTRON INTERACTIONS

ELECTRON INTERACTIONS Applications of Electron beam therapy: The principal applications are (a) the treatment of skin and lip cancers, (b) chest wall irradiation for breast cancer, (c) administering boost dose to nodes, and

More information

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO 81 Name Date Partners Lab 5 - ELECTRON CHARGE-TO-MASS RATIO OBJECTIVES To understand how electric and magnetic fields impact an electron beam To experimentally determine the electron charge-to-mass ratio

More information

Neutron source strength measurements for Varian, Siemens, Elekta, and General Electric linear accelerators

Neutron source strength measurements for Varian, Siemens, Elekta, and General Electric linear accelerators JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 4, NUMBER 3, SUMMER 2003 Neutron source strength measurements for Varian, Siemens, Elekta, and General Electric linear accelerators David S. Followill,*

More information

A comparison of methods for monitoring photon beam energy constancy

A comparison of methods for monitoring photon beam energy constancy JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 6, 2016 A comparison of methods for monitoring photon beam energy constancy Song Gao, 1a Peter A. Balter, 1 Mark Rose, 2 and William E. Simon

More information

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO 79 Name Date Partners OBJECTIVES OVERVIEW Lab 5 - ELECTRON CHARGE-TO-MASS RATIO To understand how electric and magnetic fields impact an electron beam To experimentally determine the electron charge-to-mass

More information

Variations in daily quality assurance dosimetry from device levelling, feet position and backscatter material

Variations in daily quality assurance dosimetry from device levelling, feet position and backscatter material Australas Phys Eng Sci Med (2012) 35:485 489 DOI 10.1007/s13246-012-0169-6 SCIENTIFIC NOTE Variations in daily quality assurance dosimetry from device levelling, feet position and backscatter material

More information

Lab 6 - ELECTRON CHARGE-TO-MASS RATIO

Lab 6 - ELECTRON CHARGE-TO-MASS RATIO 101 Name Date Partners OBJECTIVES OVERVIEW Lab 6 - ELECTRON CHARGE-TO-MASS RATIO To understand how electric and magnetic fields impact an electron beam To experimentally determine the electron charge-to-mass

More information

Physics LESSON PLAN PERFORMANCE OBJECTIVE(S): STUDENTS WILL BE ABLE TO:

Physics LESSON PLAN PERFORMANCE OBJECTIVE(S): STUDENTS WILL BE ABLE TO: Physics LESSON PLAN Subject: Physics Grade: 7 12 Date: 6/21/2012 Concept: The wave nature of light, Estimated Time of Lesson: 100 Minutes PERFORMANCE OBJECTIVE(S): STUDENTS WILL BE ABLE TO: (1) Understand

More information

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software GeoInstruments Application Note June 25th, 2015 FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software Summary: This support note outlines the procedure which should be followed to calibrate

More information

Photon-beams monitor-unit calculations

Photon-beams monitor-unit calculations Photon-beams monitor-unit calculations Narayan Sahoo March 24, 2011 The materials included in this lecture notes are from previous lecture notes for this course by Karl Prado, Ph.D. Introduction Standard

More information

Quality-Assurance Check of Collimator and Phantom- Scatter Factors

Quality-Assurance Check of Collimator and Phantom- Scatter Factors Quality-Assurance Check of Collimator and Phantom- Scatter Factors Ramesh C. Tailor, David S. Followill, Nadia Hernandez, Timothy S. Zhu, and Geoffrey S. Ibbott. UT MD Anderson Cancer Center, Houston TX.

More information

Overview and Status of the Austrian Particle Therapy Facility MedAustron. Peter Urschütz

Overview and Status of the Austrian Particle Therapy Facility MedAustron. Peter Urschütz Overview and Status of the Austrian Particle Therapy Facility MedAustron Peter Urschütz MedAustron Centre for ion beam therapy and non-clinical research Treatment of 1200 patients/year in full operation

More information

CHARGED PARTICLES IN FIELDS

CHARGED PARTICLES IN FIELDS The electron beam used to study motion of charged particles in electric and/or magnetic fields. CHARGED PARTICLES IN FIELDS Physics 41/61 Fall 01 1 Introduction The precise control of charged particles

More information

EXPERIMENT 7: ANGULAR KINEMATICS AND TORQUE (V_3)

EXPERIMENT 7: ANGULAR KINEMATICS AND TORQUE (V_3) TA name Lab section Date TA Initials (on completion) Name UW Student ID # Lab Partner(s) EXPERIMENT 7: ANGULAR KINEMATICS AND TORQUE (V_3) 121 Textbook Reference: Knight, Chapter 13.1-3, 6. SYNOPSIS In

More information

BEAMnrc: a code to simulate radiotherapy external beam sources

BEAMnrc: a code to simulate radiotherapy external beam sources BEAMnrc: a code to simulate radiotherapy external beam sources D.W.O. Rogers Carleton Laboratory for Radiotherapy Physics. Physics Dept, Carleton University Ottawa, Canada http://www.physics.carleton.ca/~drogers

More information

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date ATS-SOI-3660 Page: 1 of 6 Approval Block Prepared by: Signature Date Evan Parnell 08 NOV 2013 Reviewed by: Signature Date Brian Flynn 08 NOV 2013 Approved by: Signature Date Kristal Jewell 08 NOV 2013

More information

Volume 1 No. 4, October 2011 ISSN International Journal of Science and Technology IJST Journal. All rights reserved

Volume 1 No. 4, October 2011 ISSN International Journal of Science and Technology IJST Journal. All rights reserved Assessment Of The Effectiveness Of Collimation Of Cs 137 Panoramic Beam On Tld Calibration Using A Constructed Lead Block Collimator And An ICRU Slab Phantom At SSDL In Ghana. C.C. Arwui 1, P. Deatanyah

More information

Identifying the crystal orientation of the black phosphorus

Identifying the crystal orientation of the black phosphorus Identifying the crystal orientation of the black phosphorus Yu ZHANG I. Introduction Black phosphorus is a new member of 2D materials family. It has several noticeable properties, for instance, the direct

More information

Use of a radioactive check device for redundancy check of ionization chambers

Use of a radioactive check device for redundancy check of ionization chambers JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 1, NUMBER 4, FALL 2000 Use of a radioactive check device for redundancy check of ionization chambers N. P. S. Sidhu,* Alkis Rouvas, and Patrick Cadman

More information

8/3/2016. Chia-Ho, Hua St. Jude Children's Research Hospital. Kevin Teo The Hospital of the University of Pennsylvania

8/3/2016. Chia-Ho, Hua St. Jude Children's Research Hospital. Kevin Teo The Hospital of the University of Pennsylvania Bijan Arjomandy, Ph.D. Mclaren Proton Therapy Center Mark Pankuch, Ph.D. Cadence Health Proton Center Chia-Ho, Hua St. Jude Children's Research Hospital Kevin Teo The Hospital of the University of Pennsylvania

More information

Effective January 2008 All indicators in Standard / 11

Effective January 2008 All indicators in Standard / 11 Scientific Inquiry 8-1 The student will demonstrate an understanding of technological design and scientific inquiry, including process skills, mathematical thinking, controlled investigative design and

More information

IE 316 Exam 1 Fall 2012

IE 316 Exam 1 Fall 2012 IE 316 Exam 1 Fall 2012 I have neither given nor received unauthorized assistance on this exam. Name Signed Date Name Printed 1 20 pts 1. Here are 10 True-False questions worth 2 points each. Write (very

More information

PHY222 Lab 8 - Magnetic Fields and Right Hand Rules Magnetic forces on wires, electron beams, coils; direction of magnetic field in a coil

PHY222 Lab 8 - Magnetic Fields and Right Hand Rules Magnetic forces on wires, electron beams, coils; direction of magnetic field in a coil PHY222 Lab 8 - Magnetic Fields and Right Hand Rules Magnetic forces on wires, electron beams, coils; direction of magnetic field in a coil Print Your Name Print Your Partners' Names You will return this

More information

For all For every For each For any There exists at least one There exists There is Some

For all For every For each For any There exists at least one There exists There is Some Section 1.3 Predicates and Quantifiers Assume universe of discourse is all the people who are participating in this course. Also let us assume that we know each person in the course. Consider the following

More information

Density of Brass: Accuracy and Precision

Density of Brass: Accuracy and Precision Density of Brass: Accuracy and Precision Introduction Density is a measure of a substance s mass-to-volume ratio. For liquids and solids, density is usually expressed in units of g/ml or g/cm 3 ; these

More information

Physics. Sunday, March 4, :30 a.m. 10:00 a.m.

Physics. Sunday, March 4, :30 a.m. 10:00 a.m. Physics Sunday, March 4, 2018 9:30 a.m. 10:00 a.m. Social Q&A Use your phone, tablet, or laptop to Submit questions to speakers and moderators Answer interactive questions / audience response polls astro.org/refreshersocialqa

More information

Newton s Second Law. Sample

Newton s Second Law. Sample Newton s Second Law Experiment 4 INTRODUCTION In your discussion of Newton s first law, you learned that when the sum of the forces acting on an object is zero, its velocity does not change. However, when

More information

THE mono-energetic hadron beam such as heavy-ions or

THE mono-energetic hadron beam such as heavy-ions or Verification of the Dose Distributions with GEANT4 Simulation for Proton Therapy T.Aso, A.Kimura, S.Tanaka, H.Yoshida, N.Kanematsu, T.Sasaki, T.Akagi Abstract The GEANT4 based simulation of an irradiation

More information

SIGNIFICANT FIGURES BEGIN

SIGNIFICANT FIGURES BEGIN SIGNIFICANT FIGURES BEGIN and someone hands you this. Imagine you are asked to measure the length of something... How do we use it most effectively? Rulers, thermometers, and graduated cylinders, to name

More information

POLARIZATION OF LIGHT

POLARIZATION OF LIGHT POLARIZATION OF LIGHT OVERALL GOALS The Polarization of Light lab strongly emphasizes connecting mathematical formalism with measurable results. It is not your job to understand every aspect of the theory,

More information

Conservation of Mechanical Energy Activity Purpose

Conservation of Mechanical Energy Activity Purpose Conservation of Mechanical Energy Activity Purpose During the lab, students will become familiar with solving a problem involving the conservation of potential and kinetic energy. A cart is attached to

More information

Visual Analysis of the Daily QA Results of Photon and Electron Beams of a Trilogy Linac over a Five-Year Period

Visual Analysis of the Daily QA Results of Photon and Electron Beams of a Trilogy Linac over a Five-Year Period International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 2015, 4, 290-299 Published Online November 2015 in SciRes. http://www.scirp.org/journal/ijmpcero http://dx.doi.org/10.4236/ijmpcero.2015.44035

More information

Optics in a Fish Tank Demonstrations for the Classroom

Optics in a Fish Tank Demonstrations for the Classroom Optics in a Fish Tank Demonstrations for the Classroom Introduction: This series of demonstrations will illustrate a number of optical phenomena. Using different light sources and a tank of water, you

More information

Estimate of Photonuclear Reaction in a Medical Linear Accelerator Using a Water-Equivalent Phantom

Estimate of Photonuclear Reaction in a Medical Linear Accelerator Using a Water-Equivalent Phantom Progress in NUCLEAR SCIENCE and TECHNOLOGY, Vol. 2, pp.83-87 (2) ARTICLE Estimate of Photonuclear Reaction in a Medical Linear Accelerator Using a Water-Equivalent Phantom Toshioh FUJIBUCHI,2,*, Satoshi

More information

Measurement and Measurement Errors

Measurement and Measurement Errors 1 Measurement and Measurement Errors Introduction Physics makes very general yet quite detailed statements about how the universe works. These statements are organized or grouped together in such a way

More information

Development of beam delivery systems for proton (ion) therapy

Development of beam delivery systems for proton (ion) therapy 7th 28th of July 213, JINR Dubna, Russia Development of beam delivery systems for proton (ion) therapy S t u d e n t : J o z e f B o k o r S u p e r v i s o r : D r. A l e x a n d e r M o l o k a n o v

More information

Lab 6 - Electron Charge-To-Mass Ratio

Lab 6 - Electron Charge-To-Mass Ratio Lab 6 Electron Charge-To-Mass Ratio L6-1 Name Date Partners Lab 6 - Electron Charge-To-Mass Ratio OBJECTIVES To understand how electric and magnetic fields impact an electron beam To experimentally determine

More information

PHYS 281 General Physics Laboratory

PHYS 281 General Physics Laboratory King Abdul-Aziz University Faculty of Science Physics Department PHYS 281 General Physics Laboratory Student Name: ID Number: Introduction Advancement in science and engineering has emphasized the microscopic

More information

Ph 3455/MSE 3255 Experiment 2: Atomic Spectra

Ph 3455/MSE 3255 Experiment 2: Atomic Spectra Ph 3455/MSE 3255 Experiment 2: Atomic Spectra Background Reading: Tipler, Llewellyn pp. 163-165 Apparatus: Spectrometer, sodium lamp, hydrogen lamp, mercury lamp, diffraction grating, watchmaker eyeglass,

More information

Physics Overview. Assessments Assessments Adopted from course materials Teacher-created assessments Standard Physical Science

Physics Overview. Assessments Assessments Adopted from course materials Teacher-created assessments Standard Physical Science Physics Curriculum Physics Overview Course Description Physics is the study of the physical world and is a mathematical application of science. The study includes an investigation of translational and

More information

H e a l t h P h y s i c s S e r v i c e s L t d

H e a l t h P h y s i c s S e r v i c e s L t d 1 Title: Adept Medical X-Ray Shield: Scatter Radiation Shielding Grid Format Methodology 2 Background: Adept Medical X-Ray Shield (X-Ray Shield) is embedded with 0.5mm Lead (pb), offering protection from

More information

David Martin High Precision Beamline Alignment at the ESRF IWAA, Grenoble 3-7 October 2016

David Martin High Precision Beamline Alignment at the ESRF IWAA, Grenoble 3-7 October 2016 David Martin High Precision Beamline Alignment at the ESRF IWAA, Grenoble 3-7 October 2016 OVERVIEW The ESRF has just completed the Phase I Upgrade programme. The Phase I Upgrade programme was centered

More information

CHARA Meeting 2017 Pasadena, California

CHARA Meeting 2017 Pasadena, California MORE AUTOMATION Laszlo Sturmann M7 ACTUATORS LAB. LASER ALIGNMENT TELESCOPE OPTICAL ALIGNMENT NEW ACTUATORS REMOTELY ACTUATED M7 MOUNT MOTIVATION THE PRECISION OF THE COUDE ALIGNMENT WAS NOT SUFFICIENT

More information

Simulations in Radiation Therapy

Simulations in Radiation Therapy Simulations in Radiation Therapy D. Sarrut Directeur de recherche CNRS Université de Lyon, France CREATIS-CNRS ; IPNL-CNRS ; Centre Léon Bérard Numerical simulations and random processes treat cancer 2

More information

Observing the Sun Physics 107 Lab

Observing the Sun Physics 107 Lab Name: Date: Observing the Sun Physics 107 Lab In this activity, you will use a solar telescope called a Sunspotter to observe the motion of the Sun. From watching its progress across the screen, you will

More information

Radiation Shielding of a 230 MeV Proton Cyclotron For Cancer Therapy

Radiation Shielding of a 230 MeV Proton Cyclotron For Cancer Therapy Radiation Shielding of a 230 MeV Proton Cyclotron For Cancer Therapy BHASKAR MUKHERJEE Joint DESY and University of Hamburg Accelerator Physics Seminar 27 August 2009 WPE is located within the Campus of

More information

Health Physics Services Ltd

Health Physics Services Ltd 1 Title: Adept Medical STARTable: Scatter Radiation Shielding Grid Format Methodology 2 Background: Adept Medical STARTable Shield is embedded with 0.5mm Lead (Pb), offering protection from scatter radiation

More information

Physical Science Density and Measurements

Physical Science Density and Measurements Physical Science Density and Measurements Name Date Density All matter has a mass that can be measured and a volume of space that it occupies. However, the relationship between mass and volume varies greatly

More information

Intensity of Light and Heat. The second reason that scientists prefer the word intensity is Well, see for yourself.

Intensity of Light and Heat. The second reason that scientists prefer the word intensity is Well, see for yourself. IDS 102 Intensity of Light and Heat When talking about a light source, most people are more comfortable with the word brightness than they are with the word intensity. Scientists generally prefer the word

More information

Radiation Safety. PIXE PAN 2008 Ed Stech University of Notre Dame

Radiation Safety. PIXE PAN 2008 Ed Stech University of Notre Dame Radiation Safety PIXE PAN 2008 Ed Stech University of Notre Dame Outline Radiation Overview Radiation Safety in during PIXE PAN Other Safety Issues Ionizing Radiation 4 Types Alpha Beta Photon (Gamma and

More information

d = Dx subject to Stochastic programming methods for

d = Dx subject to Stochastic programming methods for Inverse planning based on probability distributions 3 Figure 1. Prostate patient who had five CT scans before treatment. Bladder and rectum filling differs from day to day and hence the location and shape

More information

ASTM E545 TUTORIAL ON PROPER IMAGE QUALITY INDICATOR USAGE

ASTM E545 TUTORIAL ON PROPER IMAGE QUALITY INDICATOR USAGE ASTM E545 IQI USAGE TUTORIAL Page 1 of 9 ASTM E545 TUTORIAL ON PROPER IMAGE QUALITY INDICATOR USAGE Neutron radiography is a non-destructive testing method similar to the more familiar x- ray, but which

More information

Experiment 4 Radiation in the Visible Spectrum

Experiment 4 Radiation in the Visible Spectrum Experiment 4 Radiation in the Visible Spectrum Emission spectra can be a unique fingerprint of an atom or molecule. The photon energies and wavelengths are directly related to the allowed quantum energy

More information

CHARACTERISTICS OF DEGRADED ELECTRON BEAMS PRODUCED BY NOVAC7 IORT ACCELERATOR

CHARACTERISTICS OF DEGRADED ELECTRON BEAMS PRODUCED BY NOVAC7 IORT ACCELERATOR ANALELE STIINTIFICE ALE UNIVERSITATII AL. I. CUZA IASI Tomul II, s. Biofizică, Fizică medicală şi Fizica mediului 2006 CHARACTERISTICS OF DEGRADED ELECTRON BEAMS PRODUCED BY NOVAC7 IORT ACCELERATOR Dan

More information

IE 316 Exam 1 Fall 2011

IE 316 Exam 1 Fall 2011 IE 316 Exam 1 Fall 2011 I have neither given nor received unauthorized assistance on this exam. Name Signed Date Name Printed 1 1. Suppose the actual diameters x in a batch of steel cylinders are normally

More information

Alberta Standards Alignment Guide

Alberta Standards Alignment Guide Alberta Standards Alignment Guide Module 1: The Skate Blades Students will be able to (SWBAT) define and identify independent variables, dependent variables, and controls in an experiment SWBAT identify

More information

IRPA 2 nd European Congress, Paris, May Session: RP in Medicine - Workers. Activation Products In Medical Linear Accelerators

IRPA 2 nd European Congress, Paris, May Session: RP in Medicine - Workers. Activation Products In Medical Linear Accelerators IRPA 2 nd European Congress, Paris, May 15-19 2006 Session: RP in Medicine - Workers Activation Products In Medical Linear Accelerators FISCHER Helmut W.*, TABOT Ben*,+, POPPE, Björn + * University of

More information

Small Field Dosimetric Measurements with TLD-100, Alanine, and Ionization Chambers

Small Field Dosimetric Measurements with TLD-100, Alanine, and Ionization Chambers Small Field Dosimetric Measurements with TLD-1, Alanine, and Ionization Chambers S. Junell a, L. DeWerd a, M. Saiful Huq b, J. Novotny Jr. b, M. uader b, M.F. Desrosiers c, G. Bednarz b a Department of

More information

Electron therapy Class 2: Review questions

Electron therapy Class 2: Review questions Electron therapy Class 2: Review questions 1 Raphex Question: T63, 2002 In what situation is electron backscatter likely to be a problem? A. Using 1cm of tissue equivalent bolus on the skin. B. Using a

More information

Comparison of two commercial detector arrays for IMRT quality assurance

Comparison of two commercial detector arrays for IMRT quality assurance JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 10, NUMBER 2, SPRING 2009 Comparison of two commercial detector arrays for IMRT quality assurance Jonathan G. Li, 1,a Guanghua Yan, 1,2 and Chihray Liu

More information

A Measuring System with Recombination Chamber for Photoneutron Dosimetry at Medical Linear Accelerators

A Measuring System with Recombination Chamber for Photoneutron Dosimetry at Medical Linear Accelerators A Measuring System with Recombination Chamber for Photoneutron Dosimetry at Medical Linear Accelerators N. Golnik 1, P. Kamiński 1, M. Zielczyński 2 1 Institute of Precision and Biomedical Engineering,

More information

Using Scientific Measurements

Using Scientific Measurements Section 3 Main Ideas Accuracy is different from precision. Significant figures are those measured precisely, plus one estimated digit. Scientific notation is used to express very large or very small numbers.

More information

Introduction To Metrology

Introduction To Metrology Introduction To Metrology Meaning of Metrology Metrology is the science of measurement. Metrology may be divided depending upon the quantity to be measured like metrology of length, metrology of time.

More information

Outline. Physics of Charge Particle Motion. Physics of Charge Particle Motion 7/31/2014. Proton Therapy I: Basic Proton Therapy

Outline. Physics of Charge Particle Motion. Physics of Charge Particle Motion 7/31/2014. Proton Therapy I: Basic Proton Therapy Outline Proton Therapy I: Basic Proton Therapy Bijan Arjomandy, Ph.D. Narayan Sahoo, Ph.D. Mark Pankuch, Ph.D. Physics of charge particle motion Particle accelerators Proton interaction with matter Delivery

More information

CASSINI CQR-800 OPERATING INSTRUCTIONS INTRODUCTION

CASSINI CQR-800 OPERATING INSTRUCTIONS INTRODUCTION HQR-800 CASSINI CQR-800 OPERATING INSTRUCTIONS INTRODUCTION CONGRATULATIONS ON YOUR PURCHASE OF THE CASSINI CQR-800 TELESCOPE. THIS TELESCOPE HAS BEEN PRODUCED TO PRECISE SPECIFICATIONS. PRIOR TO USING

More information

University of Maryland Department of Physics. Spring 2009 Final Exam 20. May (175 points) Post grades on web? (Initial, please) Yes No

University of Maryland Department of Physics. Spring 2009 Final Exam 20. May (175 points) Post grades on web? (Initial, please) Yes No University of Maryland Department of Physics Physics 122 20. May 2009 (175 points) Post grades on web? (Initial, please) Yes No (If you agree, I will post your grades and your detailed scores for each

More information

Quality Assurance Plan. March 30, Chemical Crystallography Laboratory

Quality Assurance Plan. March 30, Chemical Crystallography Laboratory Quality Assurance Plan Page 1 of 7 Quality Assurance Plan March 30, 2017 Chemical Crystallography Laboratory Author: Douglas R. Powell Quality Assurance Plan Page 2 of 7 Distribution Douglas R. Powell,

More information

EXPERIMENTAL UNCERTAINTY

EXPERIMENTAL UNCERTAINTY 3 EXPERIMENTAL UNCERTAINTY I am no matchmaker, as you well know, said Lady Russell, being much too aware of the uncertainty of all human events and calculations. --- Persuasion 3.1 UNCERTAINTY AS A 95%

More information

Theoretical analysis of comparative patient skin dose and exposure technique approaches in planar radiography

Theoretical analysis of comparative patient skin dose and exposure technique approaches in planar radiography Exposure technique Australian Institute of Radiography The Radiographer 2009; 56 (1): 21 26 Theoretical analysis of comparative patient skin dose exposure technique approaches in planar radiography Faculty

More information

Science TEKS Verification

Science TEKS Verification Science EKS Verification (1) Scientific processes. he student conducts investigations, for at least 40% of instructional time, using safe, environmentally appropriate, and ethical practices. hese investigations

More information

Build and Use a Simple Spectroscope

Build and Use a Simple Spectroscope Build and Use a Simple Spectroscope Subject Area: Physical Sciences Grade Level: 9 12 Overview In this activity students will build a spectroscope to analyze the composition of light. Our scope is inexpensive,

More information

Machine Positioning Uncertainty with Laser Interferometer Feedback

Machine Positioning Uncertainty with Laser Interferometer Feedback Machine Positioning Uncertainty with Laser Interferometer Feedback The purpose of this discussion is to explain the major contributors to machine positioning uncertainty in systems with laser interferometer

More information

Construction of a Vibrating Structure for Demonstration of Vibration Measurement

Construction of a Vibrating Structure for Demonstration of Vibration Measurement Paper ID #9316 Construction of a Vibrating Structure for Demonstration of Vibration Measurement and FFT Analysis Prof. Aaron Alexander, Oklahoma State University Aaron Alexander is an Assistant Professor

More information

LASER TEAM ANTI-BULLYING PROGRAM STUDENT WORKSHEET MASTERS AND ANSWER KEYS

LASER TEAM ANTI-BULLYING PROGRAM STUDENT WORKSHEET MASTERS AND ANSWER KEYS LASER TEAM ANTI-BULLYING PROGRAM STUDENT WORKSHEET MASTERS AND ANSWER KEYS Dear Assembly Coordinator and Teachers, The following pages contain a review of the sign language used, student worksheet masters

More information

LECTURE 1: ELECTROMAGNETIC RADIATION

LECTURE 1: ELECTROMAGNETIC RADIATION LECTURE 1: ELECTROMAGNETIC RADIATION 1.0 -- PURPOSE OF UNIT The purpose of this unit is to identify and describe some of the basic properties common to all forms of electromagnetic radiation and to identify

More information

A Thesis. entitled. Micro Ionization Chamber. Vidheesha Arora. Master of Science Degree in. Biomedical Sciences: Medical Physics

A Thesis. entitled. Micro Ionization Chamber. Vidheesha Arora. Master of Science Degree in. Biomedical Sciences: Medical Physics A Thesis entitled An Investigation of the Polarity Effects in Small Field Based on the Orientation of the Micro Ionization Chamber by Vidheesha Arora Submitted to the Graduate Faculty as partial fulfillment

More information

You Are the Spectrometer! A Look Inside Astronomy's Essential Instrument (Robert B. Friedman & Matthew K. Sharp)

You Are the Spectrometer! A Look Inside Astronomy's Essential Instrument (Robert B. Friedman & Matthew K. Sharp) You Are the Spectrometer! A Look Inside Astronomy's Essential Instrument (Robert B. Friedman & Matthew K. Sharp) Introduction Astronomy is a unique science because unlike many of the other sciences, the

More information

Pearson Edexcel GCSE Physics Unit P3: Applications of Physics

Pearson Edexcel GCSE Physics Unit P3: Applications of Physics Write your name here Surname Other names Pearson Edexcel GCSE Centre Number Physics Unit P3: Applications of Physics Friday 24 June 2016 Morning Time: 1 hour You must have: Calculator, ruler Candidate

More information

TITLE: Interferometry: The Michelson Interferometer

TITLE: Interferometry: The Michelson Interferometer TITLE: Interferometry: The Michelson Interferometer Contributed by: Yolanda Flores Baboquivari High School Summary: The lesson begins with a demonstration introducing students to interference fringes formed

More information

PLI Support Guide: Robotic Total Station Field Calibration

PLI Support Guide: Robotic Total Station Field Calibration PLI Support Guide: Robotic Total Station Field Calibration Summary: This manual will instruct you on how to properly calibrate your Trimble Robotic Total Station using Trimble Access. Your instrument must

More information

APAS Laboratory { PAGE } Spectroscopy SPECTROSCOPY

APAS Laboratory { PAGE } Spectroscopy SPECTROSCOPY SPECTROSCOPY SYNOPSIS: In this lab you will eplore different types of emission spectra, calibrate a spectrometer using the spectrum of a known element, and use your calibration to identify an unknown element.

More information

Significant Digits What digits are important when recording a measurement?

Significant Digits What digits are important when recording a measurement? Significant Digits What digits are important when recording a measurement? Why? Scientists do a lot of measuring. When scientists use an instrument (ruler, graduated cylinder, spectrophotometer, balance

More information

Physics 476LW. Advanced Physics Laboratory - Faraday Rotation

Physics 476LW. Advanced Physics Laboratory - Faraday Rotation Physics 476LW Advanced Physics Laboratory The Faraday Effect Introduction In 1845 Michael Faraday suspected that there were connections between light and electromagnetism. He conducted a series of experiments

More information

Uniformly Accelerated Motion

Uniformly Accelerated Motion Uniformly Accelerated Motion 2-1 Uniformly Accelerated Motion INTRODUCTION All objects on the earth s surface are being accelerated toward the center of the earth at a rate of 9.81 m/s 2. 1 This means

More information

City University of Hong Kong

City University of Hong Kong City University of Hong Kong Information on a Course offered by the Department of Physics and Materials Science with effect from Semester A in 2013 / 2014 Part I Course Title: Radiological Physics and

More information