To: Mitch Cottrell, Instructor From: Brian Garber, Crawford Binns, Jeff Hollis (Group 3, Sec. J) Subject: Project Deliverable #3 Date: 4 May 2010

Size: px
Start display at page:

Download "To: Mitch Cottrell, Instructor From: Brian Garber, Crawford Binns, Jeff Hollis (Group 3, Sec. J) Subject: Project Deliverable #3 Date: 4 May 2010"

Transcription

1 To: Mitch Cottrell, Instructor From: Brian Garber, Crawford Binns, Jeff Hollis (Group 3, Sec. J) Subject: Project Deliverable #3 Date: 4 May 2010 This projects intention is to investigate how adjusting certain parameters of a Venturi jet affect its performance. As the typical purpose of these devices is to induce a vacuum with a liquid to entrap a secondary material, we decided to use a pressure transducer. The only must for the transducer was that it read both positive and negative pressures as we were unsure of the performance of our fabricated system. The initial decision for our transducer was to be a differential pressure, diaphragm unit from Omega.com (PX BD5V). This sensor offered several features that made it a good choice. The option for a differential reading would have given us the option to read the pressure at different locations along the venturi and the transducer could have also been piped to read the gauge pressure of the vacuum, or measuring its difference to the ambient pressure. It was also cheap (relatively). After discussing the project though, it was decided to use an already available pressure transducer. A SUNX DP-Y27 was used in the end. This sensor s range was ±100kPa, which was more than five times the range the Omega.com transducer, and turned out to be quite necessary as our device saw higher positive that we had anticipated. The SUNX also provided a digital display built into the sensor that proved quite helpful. Another feature was the ability to withstand water. The Omega would have required remote mounting using rubber hosing, and certainly greater chances for leaks in the vacuum. With the ability of the Ramco to read water pressure without faulting, the sensor could be safely mounted directly onto the system without fear. The actual Venturi was constructed out of PVC and either cemented together or utilized high viscosity grease to seal press fittings. Consistent pressures were ensured by mounting the orifice vertically, thus keeping standing water from affecting readings. The two independent variables were the size of the nozzle and the total water flow through the nozzle. The nozzle was simply created by drilling a hole in a dead end PVC cap and increasing its diameter for each test series. The flow was determined using the flow gauge built into the pump station located in room 317. The major problem that we encountered was not being able to get the SUNX to output the analog voltage signal. After spending several hours studying the wiring diagrams and trying many different configurations, the 1V-5V signal was never found. The fault is not believed to lie with the DAQ board or the lab view program. The program is an adaptation of the same program used for the class s thermocouple homework assignment. The major changes being the alteration of the signal sampling rate, which was changed in hopes of alleviating any pulsing effects from the pump, and the inclusion of the correct equation for converting the voltage input into to pressure (Psig) output. Otherwise the program followed the same format as that of the Thermocouple homework. It created a virtual channel for the analog voltage input, which was then read by the program at a given sampling rate. This data was then combine with

2 a time to form a 2-dimensional array. Using a Butterworth filter the noise of the signal was reduced as the data got passed through numerous arithmetic blocks to convert voltage into a psi pressure. A time stamp was created and the output in psi was saved to an Excel spreadsheet (screen shots of the front panel and block diagram are located in the Appendix). This short fall did not prevent our execution of our experiment though because of the digital display located on the sensor itself. The internal circuitry displayed the pressure in Psi with a resolution of (±0.02). We did calculate the uncertainty of the readings as if the sensor had worked correctly though. There were two components that would need to be taken into account. First, the pressure transducer had four types of uncertainty, and then the USB 6009 that was used for the analog data analysis had two types of uncertainty. The nominal value of the pressure that was used in the calculation was the maximum for the transducer, psid. The transducers uncertainty calculations can be seen in (Table 1) in the attachments. These uncertainties are as follows: Pressure Resolution (Abs. Accuracy) = 0.02 psid Linearity = 0.1% F.S. = * = psid Nonrepeatability = 0.2% F.S = psid Temperature = 0.3% F.S. = psid And for the 6009: Resolution = 5/ (214-1) * 4 = psid, where the 5 represents the maximum voltage, and 4 represents the maximum used in the system Absolute Accuracy = * 4 = This produced a total uncertainty in the pressure differential of pisd through perturbation of all uncertainties, which is approximately 1% of the maximum pressure differential, but much more significant for lower pressure readings of interest. Despite this large setback, we believe that our experiment yielded honest and logical results. With our basic understanding of the fundamentals of a Venturi, we expected that an increase in vacuum would occur when the flow of the pipe increased but we were mistaken. Or at least that was not the case with our rudimentary set up. The highest vacuums were not found with either the larger flows or the larger nozzle sizes. Instead our highest recorded vacuum was from smallest hole size (0.132 ) at only two gallons per minute. The other nozzle sizes, ranging from (0.151 ) to (0.661 ) consistently had a lower vacuums (higher pressure) at a given flow rate than the nozzle size beneath them (see Table 2). This led us to the conclusion that one major consideration in the Venturi s performance is not the flow rate but rather the velocity of the water exciting the nozzle. This pattern is exemplified in Fig. 1 with the addition of altitude lines showing pressure inversely proportional to flow rate. The second pattern we noticed implied that an additional variable is key to the Venturi s performance. All of the tests ran at greater than 4.5 g/min resulted in positive pressures inside the system. This was not explained by the correlation between velocities of a higher flow and larger nozzle matching the velocity of a lower flow and smaller nozzle. The factor that we determined to be hindering the Venturi was the ratio between

3 nozzle size and pipe size. Our piping remained the same for all nozzle sizes and the steady upturn in pressure (seen in Fig. 2) means that a backpressure is being encountered downstream from the Venturi. While the couplers between joints did not prevent the lower flows from pulling a vacuum, their restriction rendered higher flows incapable of making a vacuum. While we deem this experiment a success, the sensor we used was not. Through either our fault, or a fault of the sensor, we were not able to properly utilize our LabView program or our DAQ board. From our understanding from the semesters material, we tried to eliminate any possible error that we made that would have kept the sensor from outputting properly but did not come up with any solutions besides using the attached digital display.

4 Appendix

5 Table 1 Uncertainty in Diff. Pressure Pertubation A C D F G H J K L M N Index Device Range Feature Resolution Uncert or Unc in Pdot Sig+ Sig- (uncpdot)^2 Nominal Name Res * FS Pdot Sunx DP-Y27 +/- 5V out Pres. Res. ABS Lin +/- 0.10% FS Temp +/- 0.30% FS Nonrepeat +/-.2% FS V DAQ 14 bit resolution 14 bit res V Abs Acc SUM SQRT TotUnc Pdot Table 2 Diameter in (inches) GPM

6 Pressure (Psig) Pressure (Psig) Fig: 1 Flow vs Pressure vs Nozzle Size Flow (GPM) Fig: 2 Flow vs Pressure vs Nozzle Size Flow (GPM)

1. Mark the correct statement(s)

1. Mark the correct statement(s) 1. Mark the correct statement(s) Figure to the right shows a mass measurement scale using a spring. 1.1 The span of the scale is a) 16 kg b) 21 kg c) 11 kg d) 5-16 kg 1.2 The range of the scale is a) 16

More information

Lab 1a Wind Tunnel Testing Principles & Drag Coefficients of Golf balls

Lab 1a Wind Tunnel Testing Principles & Drag Coefficients of Golf balls Lab 1a Wind Tunnel Testing Principles & Drag Coefficients of Golf balls OBJECTIVES - To perform air flow measurement using the wind tunnel. - To compare measured and theoretical velocities for various

More information

ECNG3032 Control and Instrumentation I

ECNG3032 Control and Instrumentation I sensor ECNG3032 Control and Instrumentation I Lecture 1 Temperature Sensors Sensors The sensor is the first element in the measurement system. Measurand Transducer Principle Excitation Signal Interface

More information

Hands-on Lab 3. System Identification with Experimentally Acquired Data

Hands-on Lab 3. System Identification with Experimentally Acquired Data Hands-on Lab 3 System Identification with Experimentally Acquired Data Recall that the course objective is to control the angle, rise time and overshoot of a suspended motor-prop. Towards this, the two

More information

Thermocouple Dynamic Errors Correction for Instantaneous Temperature Measurements in Induction Heating. Krzysztof Konopka 1

Thermocouple Dynamic Errors Correction for Instantaneous Temperature Measurements in Induction Heating. Krzysztof Konopka 1 Thermocouple Dynamic Errors Correction for Instantaneous Temperature Measurements in Induction Heating Krzysztof Konopka 1 1 Institute of Measurement Science, Electronics and Control, Silesian University

More information

When fluid incompressible...flow velocity, volumetric, and mass flow are proportional.

When fluid incompressible...flow velocity, volumetric, and mass flow are proportional. 11-1 Flow 11-1 Measures of Fluid Flow Flow velocity. Speed of material flowing past a plane. Volumetric flow. Volume of material passing a plane per unit time. Mass flow. Mass of material passing a plane

More information

Freescale Semiconductor

Freescale Semiconductor Freescale Semiconductor Pressure Rev 14, 10/2008 + 10 kpa Uncompensated Silicon Pressure The series silicon piezoresistive pressure sensors provide a very accurate and linear voltage output, directly proportional

More information

Experiment A4 Sensor Calibration Procedure

Experiment A4 Sensor Calibration Procedure Experiment A4 Sensor Calibration Procedure Deliverables: Checked lab notebook, Brief technical memo Safety Note: Heat gloves and lab coats must be worn when dealing with boiling water. Open-toed shoes

More information

CE 321 INTRODUCTION TO FLUID MECHANICS Fall 2009 LABORATORY 1: FLOW RATE MEASUREMENT

CE 321 INTRODUCTION TO FLUID MECHANICS Fall 2009 LABORATORY 1: FLOW RATE MEASUREMENT CE 321 INTRODUCTION TO FLUID MECHANICS Fall 2009 LABORATORY 1: FLOW RATE MEASUREMENT OBJECTIVESS To measure flow rates To assess the uncertainty of the measured flow rates To determine how to make accurate

More information

REDUCING PROCESS VARIABLITY BY USING FASTER RESPONDING FLOWMETERS IN FLOW CONTROL

REDUCING PROCESS VARIABLITY BY USING FASTER RESPONDING FLOWMETERS IN FLOW CONTROL REDUCING PROCESS VARIABLITY BY USING FASTER RESPONDING FLOWMETERS IN FLOW CONTROL David Wiklund Marcos Peluso Sr. Principal Engineer Director of Temperature and Plantweb Development Rosemount, Inc. Rosemount,

More information

Use Authorization. Signature. Date

Use Authorization. Signature. Date Use Authorization In presenting this thesis in partial fulfillment of the requirements for an advanced degree at Idaho State University, I agree that the Library shall make it freely available for inspection.

More information

Lab 1f Boiling Heat Transfer Paradox

Lab 1f Boiling Heat Transfer Paradox Lab 1f Boiling Heat Transfer Paradox OBJECTIVES Warning: though the experiment has educational objectives (to learn about boiling heat transfer, etc.), these should not be included in your report. - Obtain

More information

Experiment B6 Thermal Properties of Materials Procedure

Experiment B6 Thermal Properties of Materials Procedure Experiment B6 Thermal Properties of Materials Procedure Deliverables: Checked lab notebook, Brief technical memo Overview In this lab, you will examine the thermal properties of various materials commonly

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

O Plus Dry Bushing 69 kv system, 350 kv BIL, 3000 A. Table of contents

O Plus Dry Bushing 69 kv system, 350 kv BIL, 3000 A. Table of contents Type test report O Plus Dry Bushing 69 kv system, 0 kv BIL, 000 A Table of contents Abstract... 2 2 Certification... 2 Introduction.... Description and ratings....2 Overview of tests.... Applicable standards....4

More information

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product. Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure

More information

Experiment # 5 5. Coupled Water Tanks

Experiment # 5 5. Coupled Water Tanks Experiment # 5 5. Coupled Water Tanks 5.. Objectives The Coupled-Tank plant is a Two-Tank module consisting of a pump with a water basin and two tanks. The two tanks are mounted on the front plate such

More information

Using Microsoft Excel

Using Microsoft Excel Using Microsoft Excel Objective: Students will gain familiarity with using Excel to record data, display data properly, use built-in formulae to do calculations, and plot and fit data with linear functions.

More information

Target Insertion Flowmeter

Target Insertion Flowmeter Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted

More information

Department of Mechanical and Aerospace Engineering. MAE334 - Introduction to Instrumentation and Computers. Final Examination.

Department of Mechanical and Aerospace Engineering. MAE334 - Introduction to Instrumentation and Computers. Final Examination. Name: Number: Department of Mechanical and Aerospace Engineering MAE334 - Introduction to Instrumentation and Computers Final Examination December 12, 2003 Closed Book and Notes 1. Be sure to fill in your

More information

Air Flow through Woven Stainless Steel Mesh

Air Flow through Woven Stainless Steel Mesh Air Flow through Woven Stainless Steel Mesh Abstract It was known that a mesh screen placed across an airflow will have an evening effect, distributing both the velocity and pressure across the screen,

More information

TEMPERATURE EFFECT IN MULTIPHASE FLOW METER USING SLOTTED ORIFICE PLATE

TEMPERATURE EFFECT IN MULTIPHASE FLOW METER USING SLOTTED ORIFICE PLATE TEMPERATURE EFFECT IN MULTIPHASE FLOW METER USING SLOTTED ORIFICE PLATE A Thesis by DOHAR JONO SIHOMBING Submitted to the Office of Graduate and Professional Studies of Texas A&M University in partial

More information

Glossary Innovative Measurement Solutions

Glossary Innovative Measurement Solutions Glossary GLOSSARY OF TERMS FOR TRANSDUCERS, LOAD CELLS AND WEIGH MODULES This purpose of this document is to provide a comprehensive, alphabetical list of terms and definitions commonly employed in the

More information

6. The default plot created by Excel meets all of the requirements for a formal report plot in ME 360.

6. The default plot created by Excel meets all of the requirements for a formal report plot in ME 360. ME 360 Fall 2008 Semester Test #1 9/24/08 Closed book, closed notes portion of test. When you turn in this part of the test you will get the second part which allows a page of handwritten formulas. There

More information

MCE380: Measurements and Instrumentation Lab

MCE380: Measurements and Instrumentation Lab MCE380: Measurements and Instrumentation Lab Chapter 8: Flow Measurements Topics: Basic Flow Equations Flow Obstruction Meters Positive Displacement Flowmeters Other Methods Holman, Ch. 7 Cleveland State

More information

Temperature Project. Lab: Section K. Masahiro Inano Christopher Casey Adam Tigue

Temperature Project. Lab: Section K. Masahiro Inano Christopher Casey Adam Tigue Temperature Project Lab: Section K Masahiro Inano Christopher Casey Adam Tigue 5/06/2010 Description: For our project a container of instant tomato soup was microwaved according to the given instructions.

More information

Information and slides provided by RFD

Information and slides provided by RFD Information and slides provided by RFD OBJECTIVES Define: Velocity Discharge Nozzle pressure Nozzle reaction OBJECTIVES Find Velocity when head is known Velocity when NP is known GPM using the discharge

More information

Those data on the time required for the pitch to traverse various distances were measured in

Those data on the time required for the pitch to traverse various distances were measured in APPENDIX A: Ball Timing Measurements Those data on the time required for the pitch to traverse various distances were measured in the following way. To measure the time at which the ball was released from

More information

AC : A DIMENSIONAL ANALYSIS EXPERIMENT FOR THE FLUID MECHANICS CLASSROOM

AC : A DIMENSIONAL ANALYSIS EXPERIMENT FOR THE FLUID MECHANICS CLASSROOM AC 2011-1108: A DIMENSIONAL ANALYSIS EXPERIMENT FOR THE FLUID MECHANICS CLASSROOM Charles Forsberg, Hofstra University Charles H. Forsberg is an Associate Professor of Engineering at Hofstra University,

More information

Chapter 4 DYNAMICS OF FLUID FLOW

Chapter 4 DYNAMICS OF FLUID FLOW Faculty Of Engineering at Shobra nd Year Civil - 016 Chapter 4 DYNAMICS OF FLUID FLOW 4-1 Types of Energy 4- Euler s Equation 4-3 Bernoulli s Equation 4-4 Total Energy Line (TEL) and Hydraulic Grade Line

More information

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH No. Part Name Quantity BOM code List Price Remark 1 Panel assembly 1 201132890609 2 Air filter 2 201132890704 5 Display box

More information

EVALUATION OF A CLOSE COUPLED SLOTTED ORIFICE, ELECTRICAL IMPEDANCE, AND SWIRL FLOW METERS FOR MULTIPHASE FLOW. A Thesis MUHAMMET CEVIK

EVALUATION OF A CLOSE COUPLED SLOTTED ORIFICE, ELECTRICAL IMPEDANCE, AND SWIRL FLOW METERS FOR MULTIPHASE FLOW. A Thesis MUHAMMET CEVIK EVALUATION OF A CLOSE COUPLED SLOTTED ORIFICE, ELECTRICAL IMPEDANCE, AND SWIRL FLOW METERS FOR MULTIPHASE FLOW A Thesis by MUHAMMET CEVIK Submitted to the Office of Graduate and Professeional Studies of

More information

Applying Newton s Law of Cooling When The Target Keeps Changing Temperature, Such As In Stratospheric Ballooning Missions

Applying Newton s Law of Cooling When The Target Keeps Changing Temperature, Such As In Stratospheric Ballooning Missions Applying Newton s Law of Cooling When The Target Keeps Changing Temperature, Such As In Stratospheric Ballooning Missions James Flaten, U of MN Twin Cities, Minneapolis MN Kaye Smith, St. Catherine University,

More information

TS02 - Pre-Instructional Survey

TS02 - Pre-Instructional Survey TS02 - Pre-Instructional Survey 1. Which type of drawing provides detailed piping and process information, including wire terminations? a. Loop Wiring Diagrams b. Piping and Instrument Diagrams (P&IDs)

More information

Ideal Gas Law and Absolute Zero

Ideal Gas Law and Absolute Zero Experiment IX Ideal Gas Law and Absolute Zero I. Purpose The purpose of this lab is to examine the relationship between the pressure, volume and temperature of air in a closed chamber. To do this, you

More information

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010 Technical Notes Introduction Thermal Management for LEDs Poor thermal management can lead to early LED product failure. This Technical Note discusses thermal management techniques and good system design.

More information

Evidence for the Quantization of Electric Charge and Measurement of the Fundamental Unit of Electric Charge

Evidence for the Quantization of Electric Charge and Measurement of the Fundamental Unit of Electric Charge PHYSICS 286: Modern Physics Laboratory SPRING 2009 (K. Kumar and A. Dinsmore, March 2009) Experiment 7: The Millikan Oil Drop Experiment: INTRODUCTION Evidence for the Quantization of Electric Charge and

More information

After successfully completing this laboratory assignment, including the assigned reading, the lab

After successfully completing this laboratory assignment, including the assigned reading, the lab University of California at Santa Cruz Jack Baskin School of Engineering Electrical Engineering Department EE-145L: Properties of Materials Laboratory Lab 6: Temperature Dependence of Semiconductor Conductivity

More information

Investigation of anomalous heat production in Ni-H systems

Investigation of anomalous heat production in Ni-H systems Cerron-Zeballos, E., et al., Investigation of anomalous heat production in Ni-H systems. Nuovo Cimento Soc. Ital. Fis. A, 1996. 109A: p. 1645. Investigation of anomalous heat production in Ni-H systems

More information

TI 226H Calibration of Flow Check Devices using Positive Displacement Flow Meter

TI 226H Calibration of Flow Check Devices using Positive Displacement Flow Meter Page 1 of 9 TI 226H Calibration of Flow Check Devices using Positive Displacement Flow Meter TABLE OF CONTENTS 1. PURPOSE AND APPLICABILITY... 2 2. RESPONSIBILITIES... 2 2.1. Field Specialist... 2 2.2.

More information

Fundamentals of Particle Counting

Fundamentals of Particle Counting Fundamentals of Particle Counting 1 Particle Counting: Remains the most significant technique for determining the cleanliness level of a fluid Useful as a tool for qualification and monitoring cleanroom

More information

Introduction to 1118 Labs

Introduction to 1118 Labs Name: Partner(s): 1118 section: Desk # Date: Introduction to 1118 Labs Introductory materials are at: www.langaraphysics.com/lab.html. You may find following 3 links useful for this lab: Measurements:

More information

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1. Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark.

More information

Department of Mechanical Engineering ME 96. Free and Forced Convection Experiment. Revised: 25 April Introduction

Department of Mechanical Engineering ME 96. Free and Forced Convection Experiment. Revised: 25 April Introduction CALIFORNIA INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering ME 96 Free and Forced Convection Experiment Revised: 25 April 1994 1. Introduction The term forced convection refers to heat transport

More information

Thermal Cube. Custom-built Heat Flux Sensor

Thermal Cube. Custom-built Heat Flux Sensor Thermal Cube Custom-built Heat Flux Sensor Specifications and Construction MR. RAZIM REFAI MR. SHAMMAWI ANDERSON DR. ANDRÉ MCDONALD Table of Contents 1. Introduction... 2 1.1 Specifications [1]... 2 1.2

More information

200 kpa On-Chip Temperature Compensated Silicon Pressure Sensors

200 kpa On-Chip Temperature Compensated Silicon Pressure Sensors Freescale Semiconductor Data Sheet: Technical Data Pressure Document Number: Rev 8, 10/2012 200 kpa On-Chip Temperature Compensated Silicon Pressure The devices series are silicon piezoresistive pressure

More information

TRACKING DYNAMIC HOLD-UP OF JUICE IN A CANE BED

TRACKING DYNAMIC HOLD-UP OF JUICE IN A CANE BED REFEREED PAPER TRACKING DYNAMIC HOLD-UP OF JUICE IN A CANE BED LOUBSER R C Sugar Milling Research Institute NPC, c/o University of KwaZulu-Natal, Durban, South Africa, rloubser@smri.org Abstract Effective

More information

Course: ENGR 3280L. Section: 001. Date: 9/6/2012. Instructor: Jim Henry. Chris Hawk 9/6/2012

Course: ENGR 3280L. Section: 001. Date: 9/6/2012. Instructor: Jim Henry. Chris Hawk 9/6/2012 1 University of Tennessee at Chattanooga Steady State Operating Curve for Filter Wash Station ENGR 328L By: Red Team (Casey Villines, Brandon Rodgers) Course: ENGR 328L Section: 1 Date: 9/6/12 Instructor:

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

Speed of Light in Air

Speed of Light in Air Speed of Light in Air Electromagnetic waves represent energy in the form of oscillating electric and magnetic fields which propagate through vacuum with a speed c = 2.9979246x10 8 m/s. Electromagnetic

More information

Fall 2014 Nobby Kobayashi

Fall 2014 Nobby Kobayashi University of California at Santa Cruz Jack Baskin School of Engineering Electrical Engineering Department EE-145L: Properties of Materials Laboratory Lab 5: Temperature Dependence of Semiconductor Conductivity

More information

Experiment 5: Thermocouples (tbc 1/14/2007, revised 3/16/2007, 3/22,2007, 2/23/2009, 3/13/2011)

Experiment 5: Thermocouples (tbc 1/14/2007, revised 3/16/2007, 3/22,2007, 2/23/2009, 3/13/2011) Experiment 5: Thermocouples (tbc 1/14/2007, revised 3/16/2007, 3/22,2007, 2/23/2009, 3/13/2011) Objective: To implement a thermocouple circuit for temperature sensing. I. Introduction to Thermocouples

More information

Experiment 2 Random Error and Basic Statistics

Experiment 2 Random Error and Basic Statistics PHY9 Experiment 2: Random Error and Basic Statistics 8/5/2006 Page Experiment 2 Random Error and Basic Statistics Homework 2: Turn in at start of experiment. Readings: Taylor chapter 4: introduction, sections

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 and 1595 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test

More information

O Plus Dry Bushing 25 kv system, 150 kv BIL, 3000 A

O Plus Dry Bushing 25 kv system, 150 kv BIL, 3000 A TYPE TEST REPORT O Plus Dry Bushing 25 kv system, 150 kv BIL, 3000 A 02 1 Abstract 02 2 Certification 03 3 Introduction 03 3.1 Description and ratings 03 3.2 Overview of tests 03 3.3 Applicable standards

More information

TYPICAL PRESSURE MEASUREMENT UNCERTAINTY DEFINED BY AN FPG8601 FORCE BALANCED PISTON GAUGE

TYPICAL PRESSURE MEASUREMENT UNCERTAINTY DEFINED BY AN FPG8601 FORCE BALANCED PISTON GAUGE TYPICAL PRESSURE MEASUREMENT UNCERTAINTY DEFINED BY AN FPG8601 FORCE BALANCED PISTON GAUGE Michael Bair and Pierre Delajoud 2002 DEC 10 Revised 2004 MAR 26 FORWARD FPG8601 is a pressure standard designed

More information

No HOT WIRE ANEMOMETER MODEL SK-27V. SPECIFICATIONS Measurement object : Clean air at normal pressure and humidity

No HOT WIRE ANEMOMETER MODEL SK-27V. SPECIFICATIONS Measurement object : Clean air at normal pressure and humidity ELECTRIC INSTRUMENTS HOT WIRE ANEMOMETERS No. 7693-00 HOT WIRE ANEMOMETER MODEL SK-73D Measurement object: Clean air at normal pressure and humidity Measuring range Air velocity : 0 to 30 m/s Air temperature:

More information

Electrolytic Tiltmeter Temperature Coefficients: Source, Definition and Use to Improve Accuracy

Electrolytic Tiltmeter Temperature Coefficients: Source, Definition and Use to Improve Accuracy Electrolytic Tiltmeter Temperature Coefficients: Source, Definition and Use to Improve Accuracy Introduction Environmental temperature changes alter the mechanical and electrical characteristics of all

More information

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer Temperature Control without Compromise: rapid changes, precise temperatures, powerful complex functionality.

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook Reference Manual 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com Reference Manual 405 and 1595 405 Compact Orifice Series and 1595 Conditioning

More information

SCB10H Series Pressure Elements PRODUCT FAMILY SPEFICIFATION. Doc. No B

SCB10H Series Pressure Elements PRODUCT FAMILY SPEFICIFATION. Doc. No B PRODUCT FAMILY SPEFICIFATION SCB10H Series Pressure Elements SCB10H Series Pressure Elements Doc. No. 82 1250 00 B Table of Contents 1 General Description... 3 1.1 Introduction... 3 1.2 General Description...

More information

Frictional Losses in Straight Pipe

Frictional Losses in Straight Pipe 2/2/206 CM325 Fundamentals of Chemical Engineering Laboratory Prelab Preparation for Frictional Losses in Straight Pipe Professor Faith Morrison Department of Chemical Engineering Michigan Technological

More information

Assembly and Operation Manual. April 2016

Assembly and Operation Manual. April 2016 Assembly and Operation Manual April 2016 Table of Contents What is in the OurWeather Box? 3 Step by Step Assembly 13 Building the Weather Sensors 18 Testing the OurWeather Weather Station 28 Power Up OurWeather

More information

ORDERING INFORMATION # of Ports Pressure Type Device Name

ORDERING INFORMATION # of Ports Pressure Type Device Name Rev 13, 10/2008 10 kpa On-Chip Temperature + Compensated and Calibrated Silicon Pressure The series silicon piezoresistive pressure sensors provide a very accurate and linear voltage output directly proportional

More information

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5 Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring

More information

Fitting PS P - B - R2

Fitting PS P - B - R2 INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable

More information

PG-200/PG-208 PRESSURE GAUGES P G G P P

PG-200/PG-208 PRESSURE GAUGES P G G P P Digital 3 1/2 digits monitor Set button for switch output HI or LO (PG-200) (PG-208) Digital 3 1/2 digits Power switch LO setting VR for switch output LO HI setting VR for switch output HI SPAN adjustment

More information

Thrust Measuring Test Stand - Experiment Lab - Horizontal Forces / Vectors. SeaPerch Activity

Thrust Measuring Test Stand - Experiment Lab - Horizontal Forces / Vectors. SeaPerch Activity Thrust Measuring Test Stand - Experiment Lab - Horizontal Forces / Vectors Review SeaPerch Activity After completing the lab on vectors and forces, you should recall that vectors are different from measured

More information

CALIBRATION CERTIFICATE FAILURE EXPLANATION FOR AEROTRAK PARTICLE COUNTERS

CALIBRATION CERTIFICATE FAILURE EXPLANATION FOR AEROTRAK PARTICLE COUNTERS CALIBRATION CERTIFICATE FAILURE EXPLANATION FOR AEROTRAK PARTICLE COUNTERS APPLICATION NOTE CC-119 (A4) This application note works through the As Found Calibration Certificate of the AeroTrak Counters

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

5. DRIVE 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 6. ROW UNIT 7. OPTIONAL EQUIPMENT

5. DRIVE 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 6. ROW UNIT 7. OPTIONAL EQUIPMENT TABLE OF CONTENTS 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 5. DRIVE 6. ROW UNIT 7. OPTIONAL EQUIPMENT DRIVE Standard Turbofan 540, 450 & 1000 RPM with PTO Drive Your Monosem planter will be equipped

More information

Looking at a two binary digit sum shows what we need to extend addition to multiple binary digits.

Looking at a two binary digit sum shows what we need to extend addition to multiple binary digits. A Full Adder The half-adder is extremely useful until you want to add more that one binary digit quantities. The slow way to develop a two binary digit adders would be to make a truth table and reduce

More information

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes SELECCIÓN DE CAUDALIMETROS Tablas de Fabricantes Flow Meter Selection Table http://www.instrumart.com/content.aspxcontentid=219 Página 1 de 1 17/09/2007 KEY Best for this application OK with some exceptions

More information

EM375 MECHANICAL ENGINEERING EXPERIMENTATION THERMOCOUPLE LABORATORY

EM375 MECHANICAL ENGINEERING EXPERIMENTATION THERMOCOUPLE LABORATORY EM375 MECHANICAL ENGINEERING EXPERIMENTATION THERMOCOUPLE LABORATORY PURPOSE The objective of this laboratory is to introduce the student to the manufacture and use of thermocouples. Thermocouples will

More information

Steady State Operating Curve: Speed UTC Engineering 329

Steady State Operating Curve: Speed UTC Engineering 329 Steady State Operating Curve: Speed UTC Engineering 329 Woodlyn Knight Madden, EI September 6, 7 Partners: Megan Miller, Nick Rader Report Format Each section starts on a new page. All text is double spaced.

More information

ME 4600:483 Lab Notes Revised 11/16/2015. Flow Measurement

ME 4600:483 Lab Notes Revised 11/16/2015. Flow Measurement Table of Contents Flow Measurement Flow Measurement... 1 I. Objective... 1 II. Apparatus... 1 III. Principles and Background... 1 Pitot-Static Tubes... 2 Orifice Plates and Unrecoverable Losses... 4 Flow

More information

Technical Data Sheet DPT & DPIT-4005 SERIES DIFFERENTIAL PRESSURE TRANSDUCERS. Features. Description

Technical Data Sheet DPT & DPIT-4005 SERIES DIFFERENTIAL PRESSURE TRANSDUCERS. Features. Description Technical Data Sheet DPT & DPIT-4005 SERIES DIFFERENTIAL PRESSURE TRANSDUCERS Description The 4005 series of differential pressure transducers include Models DPT-4005 and DPIT-4005-M. The 4005 series differential

More information

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006% ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX

More information

1.4 System Accuracy* B. G. LIPTÁK (1982, 1995, 2003) DEFINITIONS OF TERMS

1.4 System Accuracy* B. G. LIPTÁK (1982, 1995, 2003) DEFINITIONS OF TERMS 1.4 System Accuracy* B. G. LIPTÁK (1982, 1995, 23) DEFINITIONS OF TERMS Accuracy (Webster). Freedom from error or the absence of error. Syn. precision, correctness, exactness. (In this sense, the term

More information

Virtual Instrument for Crimped Connections Temperature and Specific Losses Monitoring During. Electrical Tests

Virtual Instrument for Crimped Connections Temperature and Specific Losses Monitoring During. Electrical Tests American Journal of Energy and Power Engineering 2017; 4(6): 98-104 http://www.aascit.org/journal/ajepe ISSN: 2375-3897 Virtual Instrument for Crimped Connections Temperature and Specific Losses Monitoring

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

Theory and Design for Mechanical Measurements

Theory and Design for Mechanical Measurements Theory and Design for Mechanical Measurements Third Edition Richard S. Figliola Clemson University Donald E. Beasley Clemson University John Wiley & Sons, Inc. New York / Chichester / Weinheim / Brisbane

More information

Siddharth Institute of Engineering & Technology

Siddharth Institute of Engineering & Technology SIDDHARTH INSTITUTE OF ENGINEERING & TECHNOLOGY :: PUTTUR (AUTONOMOUS) (Approved by AICTE, New Delhi & Affiliated to JNTUA, Anantapuramu) (Accredited by NBA & Accredited by NAAC with A Grade) (An ISO 9001:2008

More information

Laboratory 1: Calibration of a High-Volume Sampler

Laboratory 1: Calibration of a High-Volume Sampler Laboratory 1 Laboratory 1: Calibration of a High-Volume Sampler 1.1 To the User of this Manual This manual has been prepared to guide the students through a series of laboratory exercises developed to

More information

Thermal Cube. Custom-built Heat Flux Sensor

Thermal Cube. Custom-built Heat Flux Sensor Thermal Cube Custom-built Heat Flux Sensor Specifications and Construction MR. RAZIM REFAI MR. SHAMMAWI ANDERSON DR. ANDRÉ MCDONALD Table of Contents 1. Introduction... 2 1.1 Specifications [1]... 2 1.2

More information

In this experiment, the concept of electric field will be developed by

In this experiment, the concept of electric field will be developed by Physics Equipotential Lines and Electric Fields Plotting the Electric Field PURPOSE MATERIALS 5 alligator clip leads 2 batteries, 9 V 2 binder clips, large computer In this experiment, the concept of electric

More information

Orifice and Venturi Pipe Flow Meters

Orifice and Venturi Pipe Flow Meters Orifice and Venturi Pipe Flow Meters by Harlan H. Bengtson, PhD, P.E. 1. Introduction Your Course Title Here The flow rate of a fluid flowing in a pipe under pressure is measured for a variety of applications,

More information

SPECIFICATIONS PARTICLE SENSOR KS-28B Higashimotomachi, Kokubunji, Tokyo , Japan

SPECIFICATIONS PARTICLE SENSOR KS-28B Higashimotomachi, Kokubunji, Tokyo , Japan SPECIFICATIONS PARTICLE SENSOR KS-28B 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 99020-4E 07-04 Printed in Japan Outline The KS-28B is a particle sensor designed to measure the number

More information

200 kpa On-Chip Temperature. Compensated Silicon Pressure Sensors. MPX2200 Series. Pressure. Application Examples. Features. MPX2200 Rev 13, 10/2008

200 kpa On-Chip Temperature. Compensated Silicon Pressure Sensors. MPX2200 Series. Pressure. Application Examples. Features. MPX2200 Rev 13, 10/2008 Pressure Rev 13, 10/2008 200 kpa On-Chip Temperature + Compensated ilicon Pressure The series devices are silicon piezoresistive pressure sensor providing a highly accurate and linear voltage output directly

More information

Remember that C is a constant and ë and n are variables. This equation now fits the template of a straight line:

Remember that C is a constant and ë and n are variables. This equation now fits the template of a straight line: CONVERTING NON-LINEAR GRAPHS INTO LINEAR GRAPHS Linear graphs have several important attributes. First, it is easy to recognize a graph that is linear. It is much more difficult to identify if a curved

More information

Week 14 The Simple Pendulum

Week 14 The Simple Pendulum Week 14 The Simple Pendulum 1. Scope 1.1 Goal Conduct experiment to study the simple harmonic motion of an oscillatory pendulum and analyze and interpret the data 1.2 Units of measurement to use United

More information

AE 3051, Lab #16. Investigation of the Ideal Gas State Equation. By: George P. Burdell. Group E3

AE 3051, Lab #16. Investigation of the Ideal Gas State Equation. By: George P. Burdell. Group E3 AE 3051, Lab #16 Investigation of the Ideal Gas State Equation By: George P. Burdell Group E3 Summer Semester 000 Abstract The validity of the ideal gas equation of state was experimentally tested for

More information

EXPERIMENT 30A1: MEASUREMENTS. Learning Outcomes. Introduction. Experimental Value - True Value. 100 True Value

EXPERIMENT 30A1: MEASUREMENTS. Learning Outcomes. Introduction. Experimental Value - True Value. 100 True Value 1 Learning Outcomes EXPERIMENT 30A1: MEASUREMENTS Upon completion of this lab, the student will be able to: 1) Use various common laboratory measurement tools such as graduated cylinders, volumetric flask,

More information

Lab #4 Similitude: The Kármán Vortex Street CEE 331 Fall 2004

Lab #4 Similitude: The Kármán Vortex Street CEE 331 Fall 2004 CEE 331 Lab 4 Page 1 of 6 Lab #4 Similitude: The Kármán Vortex Street CEE 331 Fall 2004 Safety The major safety hazard in this laboratory is a shock hazard. Given that you will be working with water and

More information

IQI IQI. Proposal of quadratic equation for prediction of flow rates versus pressure in packed beds of cement. By Jan Malczyk

IQI IQI. Proposal of quadratic equation for prediction of flow rates versus pressure in packed beds of cement. By Jan Malczyk IQI IQI InstruQuest, Inc. December, 2018 Proposal of quadratic equation for prediction of flow rates versus pressure in packed beds of cement By Jan Malczyk Based on experimental measurements of flow rates

More information

The Indestructibility of Hardtack:

The Indestructibility of Hardtack: The Indestructibility of Hardtack: Radiation, Flames and Fire Arms Emily Briggs Michael Miller Aaron Thornton ME 240 Instructor Mitch Cottrell Spring 2010 Introduction Hardtack has been a staple in soldier

More information

Calibrate Rotameter and Orifice Meter and Explore Reynolds #

Calibrate Rotameter and Orifice Meter and Explore Reynolds # CM3215 Fundamentals of Chemical Engineering Laboratory Calibrate Rotameter and Orifice Meter and Explore Reynolds # Extra features! Professor Faith Department of Chemical Engineering Michigan Technological

More information

Arduino Software: How long before my battery is dead?, version 2.4

Arduino Software: How long before my battery is dead?, version 2.4 Arduino Software: How long before my battery is dead?, version 2.4 By R. G. Sparber Protected by Creative Commons. 1 When powering an Arduino from a battery, it can be useful to be able to monitor available

More information

Introduction to Determining Power Law Relationships

Introduction to Determining Power Law Relationships 1 Goal Introduction to Determining Power Law Relationships Content Discussion and Activities PHYS 104L The goal of this week s activities is to expand on a foundational understanding and comfort in modeling

More information

Page AC : INSTRUMENTATION FOR SHOCK AND IMPACT ANALYSIS

Page AC : INSTRUMENTATION FOR SHOCK AND IMPACT ANALYSIS AC 2010-2123: INSTRUMENTATION FOR SHOCK AND IMPACT ANALYSIS Randy Buchanan, University of Southern Mississippi Steven Bunkley, University of Southern Mississippi American Society for Engineering Education,

More information