IMKO TC3/APMF '98. Proceedings of. Taejon, Republic. Organized by Korea Research Institute of Standards and Science (KRISS)
|
|
- Lillian Casey
- 5 years ago
- Views:
Transcription
1 IMKO TC3/APMF '98 Proceedings of the 16th International Conference on Force, Mass and Torque Measurements in Parallel with Asia-Pacific Symposium on Measurement of Mass and Force September 1998 Taejon, Republic of Korea Edited by Myung Sai Chung Organized by Korea Research Institute of Standards and Science (KRISS) Hosted by Korea Association of Standards and Testing Organizations (KASTO) Sponsored by International Measurement Confederation (IMEKO) TC3
2 Contents I Invited Lectures The activity of the Consultative Committee for the Mass and the Related Quantities - (CCM) Past, Kozo llzuka present and future 3 National standards system 13 Sekyung Lee Uncertainty in force measurement 20 Giullo Barbate I Session I. Hydraulic Force Machine and Build-up Systems Build-up system force standards in compression and in tension up to 9 MN at BNM- LNE 37 A. Gosset, P. Averlant Development and calibration of a build-up system for forces of -up P. Anderegg, W. Honegger, W. Sennhauser, R. Kumme, A. Sawla to 21 MN 45 Evaluation of the uncertainty of the hydraulic force standard machine 54 C. Shi Application of an infinite impulse response fitter for precision calibration of a build-up system in a deadweight force machine 60 Y. K. Park, D. I. Kang, B. D. Lim I Session II. Deadweight Force Machine A new automatic deadweight machine for testing weighing instruments up R. Schwartz, H. Gassmann, D. Airey, W. Baars, P. Brandes to 3 t 69 Force metrology in Italy: The new 1 MN deadweight force standard 75 C, Ferrero, C. Marinarl, E. Martino i
3 Structural and performance characteristics of newly developed 3 kn deadweight force standard machine 83 T. Tojo ln-srtu calibration of a dead-weight force machine 89 J. Man, D. Tyrrell, D. Groeneveld Determination of the masses' value and uncertainty for the 150 kn force national standard from CENAM-Mexico 95 A. Franco P., J. Mendoza I., J. C. Torres G. I Session III. Force Transducers and Indicator Design and evaluation of a compact size six-component loadcell 105 J. W. Joo, K. S. Na, D. I. Kang Load application and measuring behaviour of a bending ring force transfer standard 112 T. Allgeler, H. Gassmann, A. Sawla Three-axis strain gauged force transducers 118 D. M. Stefanescu, T. Manescu Analysis of gyroscopic sensor applied to force measurement - Vectorial measurement of horizontal force 128 M. Kasahara, S. Kurosu, M. Adachi, K. Kamlmura Multi-channel high-precision measuring systems 137 M. Kreuzer A fast precision-adc with integrated telemetry for extremely stiff torque sensors 146 U. Bernhardt, K. Horn - Strain gauge based load cell The possibility of software creep error compensation D. Kovacevic, S. Skundrlc, S. Mlklclc, B. Dimltrljevlc 154 I Session IV. Moss (I) Using a 1 kg mass comparator to calibrate submuwples to 1 g 163 R. S. Davis, M. J. Coarasa Loaded strips as low-loss torsion elements 168 J. W. Chung, R, S. Davis Contamination on TiN and BN thin films deposited on stainless steel by IBAD 173 S, K. Lee, J. Y. Llm, Y. H. Shin, S. S. Hong, K. H. Chung ii
4 B Session V. Mass (II) Carbon dioxide determination for high accuracy weighings 183 M. Plassa, M. Mosca, M. Sega Further investigations on cleaning-washing of platinum-iridium kilograms 192 W. Blch, V. De Glronimo A weight handler for a 5 g mass comparator 198 H. Kajastie, J. Manninen, K. Riski, H. Rossi Determination of waiting time of cleaned weights before calibration 203 S. Kacmaz, V. Ciftgl I Session VI. Mass (III) A versatile automatic weight changer for mass comparators 209 M. T. Clarkson, C. M. Sutton, D. G. Jack Research on our OIML class E-, 1 g to 20 kg nonmagnetic stainless steel weight set 216 R. Sun, H. Yao, L. Wang, N. Mo, Y. Pei Weight calibration by mass comparators with automatic weight exchanging mechanism M. Uekl, Y. Nezu, S. Mlzushima, A. Oolwa 220 On the scale using a circumferentially fixed disc 227 Y. Yoshlmura, T. Tsutsumi I Session VII. Mass and Density In situ direct determination of air density using Pt-lr and St. St. standards 233 W. G. Lee, J. Y. Do, J. W. Chung Air density determination using 1 kg buoyancy mass comparison (l) 237 J. Y. Do, J. W. Chung, K. H. Chang Application of statistics to oil density measurement 242 K. H. Chang, Joel T. Park I Session VIII. Force Calibrations and Measurements The possibility of force transducer calibration using with lower capacity force standard machines 255 S. Fank, H. Parlakturk iii
5 Application of the continuous calibration procedure for industrial standard calibration of torque-and force-transducers 260 D. Kenzler Dental implants: in vivo and in vitro measurements of functional loading 264 K. Haselhuhn, Th. Bruns, G. Schrobsdorff, 0. Kranz, L. W. R. Kobes, M. Peters I Session IX. Torque Measurements Calibration of torque measuring devices - D. Peschel, A. Bruge step-by-step or continuous procedure 275 Investigation of the influence of disturbing components on the torque measurement D. Roske 280 A research on the dynamic performance of torquemeter and its calibration method 286 W. Shang, Y. Wang, T. Lee, M. Lin Evaluation of the uncertainty of torque for the dead-weight torque standard machine Y. Zhang, W. Shang 290 Development of high-qualified transfer transducer for torque and testing the calibration device 294 A. Pusa I Session X. Dynamic Forces and Mass Novel method of weighing data-processing under floor vibration 303 T. Ono, Y. FuJIoka, J. Sun Quasistatic and dynamic investigation methods of piezoelectric force measuring devices O. Mack, R. Kumme 310 A mass-estimation method with linear regression models for in-motion vehicles using axle weighing system 321 T. Ono, K. Fukuda, K. Yoshlda, H. Tottorl Load measurement by two freedom dynamic crane scale 329 L. Chen, N. Aoshima Dynamic model on force feedback system for nano-newton force measurement 338 N. Kato, H. Klkuta, T. Matumoto, K. Iwata Perspective on APMF 346 L. Wang iv
6 1 Poster Session Force Standard Machines and Intercomparlsons Uncertainty evaluation of 2 MN hydraulic force machine through intercomparison measurement 353 D. I. Kang, H. K. Song, J. T. Lee, R. Kumme, A. Sawla IMGC-CNR and KRISS deadweight force standard machines intercomparison 358 C. Ferrero, C. Marinari, E. Martlno, D. I. Kang, G. S. Kim, H. K. Song, J. T. Lee Accreditation of a Romanian 32 MN force calibration laboratory within DKD 366 A. Marinescu, I. Dumbrava, Gh. Opran, D. Popa, A. Sawla, D. Peschel, M. Peters High accuracy technology research on the lever force standard machine 376 G. L. Wu, F. Zhao A new N range force standard systems for the force calibration laboratories 379 S. Fank Characterization of the 2 MN hydraulic force comparator machine of CEM 383 J. A. Robles Carbonell, J. A. Fernandez Garcia, J. Robles Verdecla, A. Lobo Robledo Development of a 100 kn deadweight force standard machine 389 G. S. Kim, H. K. Song, D. I. Kang, J. H. Ahn, W. S. Kim Intercomparison in tension of the large force standard machines of the BNM-LNE and PTB 395 A. Gosset, P. Averlant, A. Sawla, F. Kohler, W. Schmelter Load Cells and Applications Valuation of rolling force and torque of steel through modeling with the aid of hot compression tests 403 T. A. El-Bitar Thin load cell for weighing scales 408 C. Maeda Calibration unit for three quantities: torque, force and pressure 415 P. D. Hohmann Experiences with the new revised OIML recommendation R60 for load cells 419 B. Meaner V
7 Design of new spring type constant-force mechanisms 429 W. K. Kim, D. I. Kang, H. S. Kim, M. G. Kim Nonlinear finite element analysis according to design parameters of a column type load cell 436 C. Y. Lee, D. I. Kang Application of 3-component load cell to surface characteristics measurement system for tactile perception 442 Y. H. Kwon, D. I. Kang Torque wrench calibration according to ISO 6789 and supplements 447 D. Kenzler, D. Peschel Non-contact magnetostrictive torque sensor 450 R. Ishino Effect of floor vibration on a double-beam type loadcell scale 460 M. Nakatanl, K. Kameoka, G, Komatsu, N. Inui, K. Nalto, H. Konlshi, Y. Shlmomae Study of the inspection system for the rail load, vehicle status and running safety J. LI, M. Liu 468 Mass Standards and Applications Plasticity in weighing instruments, or others, using contact knife-bearing 477 M, Renoult Automatic 50 kg weight handler 481 T. K. Chan. K. K. Hau, C. F. Yuen Observation and analysis of linearity error for the weighing instruments 486 S. Kacmaz, M. H. Orhan, S. Fank Stability of sinkers for establishment of mass standard Y. Nezu, M. Ueki, A. Ooiwa Accurate mass measurement of two 1 kg silicon spheres(s4, S5) for the determination of the Avogadro constant 493 Y. Nezu, K. Fujil, M, Tanaka, A. Ooiwa Implementation and understanding of OIML R76 international recommendation 497 R. Chen, Y. Ru Water adsorption on the stainless steel surface studied by null ellipsometry 500 D. J. Bae, H. S. Nham, J. Y. Do vi
8 Influence of a performer on mass calibration A. Kolar, M. Grum 507 Experimental Mechanics A development of dynamometer for measurement of high-frequency cutting force 515 K. Y. Lee, J. S. Kim, D. W. Lee, M. C. Kang Strain measurement of structures by digital signal processing of a passive quadrature demodulated 3x3 fiber optic Michelson interferometric sensor 520 I. B. Kwon, M. S. Bae Effects of micro structural and mechanical factors on fatigue limit in SGI 527 M. G. Kim, J. H. Kim Index 535 vii
Comparison between the CENAM (Mexico) 150 kn and the INRiM (Italy) 1 MN force standard machines
IMEKO 20 th TC3, 3 rd TC16 and 1 st TC22 International Conference Cultivating metrological knowledge 27 th to 30 th November, 2007. Merida, Mexico. Comparison between the CENAM (Mexico) 150 kn and the
More informationEVALUATION OF STATIC AND DYNAMIC PARASSITIC COMPONENTS ON THE INRIM 1 MN PRIMARY FORCE STANDARD MACHINE BY MEANS THE 500 kn SIX-COMPONENT DYNAMOMETER
XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal EVALUATION OF STATIC AND DYNAMIC PARASSITIC COMPONENTS ON THE INRIM 1 MN PRIMARY FORCE STANDARD MACHINE
More informationSeptember 17-21, 2001, Istanbul / TURKEY
INTERNATIONAL MEASUREMENT CONFEDERATION Technical Committee TC3 on Measurement of Force, Mass and Torque Proceedings of the 17 International Conference FORCE, MASS, TORQUE AND PRESSURE MEASUREMENTS AT
More informationUNCERTAINTY IN TORQUE CALIBRATION USING VERTICAL TORQUE AXIS ARRANGEMENT AND SYMMETRICAL TWO FORCE MEASUREMENT
UNCERTAINTY IN TORQUE CALIBRATION USING VERTICAL TORQUE AXIS ARRANGEMENT AND SYMMETRICAL TWO FORCE MEASUREMENT Dieter Kenzler 1, Jörg Oblasser 2, Andreas Subaric-Leitis 2 and Christian Ullner 2 1 ) SCHATZ
More informationIncreased Requirements for Higher Nominal Forces, Necessities and Possibilities to Measure Them
B 3.1 Increased Requirements for Higher Nominal Forces, Necessities and Possibilities to Measure Them Dr. Schäfer, André Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45, 64293 Darmstadt andre.schaefer@hbm.com
More informationPTB S 16.5 MN HYDRAULIC AMPLIFICATION MACHINE AFTER MODERNIZATION
IMEKO 22 nd TC3, 15 th TC5 and 3 rd TC22 International Conferences 3 to 5 February, 2014, Cape Town, Republic of South Africa PTB S 16.5 MN HYDRAULIC AMPLIFICATION MACHINE AFTER MODERNIZATION R. Kumme
More informationEvaluation of Force Standard Machines by using Build-up System
Evaluation of Force Standard Machines by using Build-up System TC3 Round Table Nov. 24, 2010 Y.-K. Park and D.-I. Kang Contents Introduction Basic theory Application examples Dynamic behavior of deadweight
More informationXIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal
XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 9, Lisbon, Portugal IMPROVEMENT OF METROLOGICAL CHARACTERISTICS OF INTI S 11 kn FORCE STANDARD MACHINE BY USING THE CENAM S SIX-COMPONENT
More informationForce/Torque measuring facility for friction coefficient and multicomponent
DOI 10.516/sensor013/A1. Force/Torque measuring facility for friction coefficient and multicomponent sensors S. Baumgarten 1, D. Röske 1, H. Kahmann 1, D. Mauersberger 1 and R. Kumme 1 1 Physikalisch-Technische
More informationTHE NEW 1.1 MN m TORQUE STANDARD MACHINE OF THE PTB BRAUNSCHWEIG/GERMANY
THE NEW 1.1 MN m TORQUE STANDARD MACHINE OF THE PTB BRAUNSCHWEIG/GERMANY D. Peschel 1, D. Mauersberger 1, D. Schwind 2, U. Kolwinski 2 1 Solid mechanics department, PTB, Germany 2 Gassmann Theiss Messtechnik
More informationCertification of a High Capacity Force Machine for Testing of Load Cells According to OIML R60
Certification of a High Capacity Force Machine for Testing of Load Cells According to OIML R60 Bernd Meißner Physikalisch-Technische Bundesanstalt Weighing Instruments Laboratory Braunschweig Abstract
More informationCOMPLETION AND MEASUREMENT UNCERTAINTY BUDGET OF THE MULTI-COMPONENT MEASURING DEVISE FOR FORCE UP TO 1 MN AND TORQUE UP TO 2 KN M
XXI IMEKO World Congress Measurement in Research and Industry August 30 September 4, 2015, Prague, Czech Republic COMPLETION AND MEASUREMENT UNCERTAINTY BUDGET OF THE MULTI-COMPONENT MEASURING DEVISE FOR
More informationFEEDBACK CONTROLLED DEADWEIGHT MACHINE
FEEDBACK CONTROLLED DEADWEIGHT MACHINE G. Barbato 1, S. Desogus 2, A. Germak 2 and M. Vattasso 3 1 DSPEA, Politecnico di Torino, C.so Duca degli Abruzzi 24, 10129 Torino, Italy 2 Istituto di Metrologia
More informationInvestigation of Piezoelectric Force Measuring Devices in Force Calibration and Force. Standard Machines
Proceedings of the 17 th International Conference on Force, Mass, Torque and Pressure Measurements, Investigation of Piezoelectric Force Measuring Devices in Force Calibration and Force Standard Machines
More informationMETHODS TO CONFIRM THE MEASUREMENT CAPABILITY OF THE FORCE STANDARD MACHINES AFTER REINSTALLATION
IMEKO 22 nd TC3, 12 th TC5 and 3 rd TC22 International Conferences 3 to 5 February, 2014, Cape Town, Republic of South Africa METHODS TO CONFIRM THE MEASUREMENT CAPABILITY OF THE FORCE STANDARD MACHINES
More information+ + ( indicator ) + (display, printer, memory)
CERTIFICATION OF STRAIN GAUGE LOAD CELL FAMILIES B. Meissner Physikalisch-Technische Bundesanstalt Weighing Instruments Laboratory 38116 Braunschweig, Germany Abstract: Testing and certification of load
More informationMulti-Capacity Load Cell Concept
Sensors & Transducers 4 by IFSA Publishing, S. L. http://www.sensorsportal.com Multi-Capacity Load Cell Concept Seif. M. OSMAN, Ebtisam H. HASAN, H. M. EL-HAKEEM, R. M. RASHAD, F. KOUTA National Institute
More informationFoundations of Ultraprecision Mechanism Design
Foundations of Ultraprecision Mechanism Design S.T. Smith University of North Carolina at Charlotte, USA and D.G. Chetwynd University of Warwick, UK GORDON AND BREACH SCIENCE PUBLISHERS Switzerland Australia
More informationUncertainty of Calibration. Results in Force Measurements
Publication Reference EAL-G Uncertainty of Calibration Results in Force Measurements PURPOSE This document has been produced to improve the harmonization in determination of uncertainties in force measurements.
More information18th IMEKO TC3 Conference on Force, Mass and Torque 2002
18th IMEKO TC3 Conference on Force, Mass and Torque 2002 Joint International Conference on Force, Mass, Torque, Hardness and Civil Engineering Metrology in the Age of Globalization Celle, Germany 24 26
More informationFORCE NATIONAL STANDARDS COMPARISON BETWEEN CENAM/MEXICO AND NIM/CHINA
FORCE NATIONAL STANDARDS COMPARISON BETWEEN CENAM/MEXICO AND NIM/CHINA Qingzhong Li *, Jorge C. Torres G.**, Daniel A. Ramírez A.** *National Institute of Metrology (NIM) Beijing, 100013, China Tel/fax:
More informationEVALUATION OF ADSORPTION EFFECT BY USING SILICON SPHERE AND SILICON SURFACE ARTEFACTS
XVIII IMEKO WORLD CONGRESS Metrology for a Sustainable Development September, 17 22, 2006, Rio de Janeiro, Brazil EVALUATION OF ADSORPTION EFFECT BY USING SILICON SPHERE AND SILICON SURFACE ARTEFACTS Jin
More informationDESIGN, DEVELOPMENT, AND COMMISSIONING OF A 120 kn DEADWEIGHT FORCE STANDARD MACHINE
DESIGN, DEVELOPMENT, AND COMMISSIONING OF A 120 kn DEADWEIGHT FORCE STANDARD MACHINE Andy Knott National Physical Laboratory, United Kingdom ABSTRACT This paper describes the development of a 120 kn deadweight
More informationConcept and setup of a multi-component facility for force and torque in the range of 1 MN and 2 kn m
CT IMEKO June 2014, Volume 3, Number 2, 39 43 www.imeko.org Concept and setup of a multi-component facility for force and torque in the range of 1 MN and 2 kn m Sebastian aumgarten, Dirk Röske, Holger
More informationINVESTIGATION OF IMPACT HAMMER CALIBRATIONS
IMEKO 23 rd TC3, 13 th TC5 and 4 th TC22 International Conference 30 May to 1 June, 2017, Helsinki, Finland INVESTIGATION OF IMPACT HAMMER CALIBRATIONS M. Kobusch 1, L. Klaus 1, and L. Muñiz Mendoza 2
More informationAutomated volume measurement for weihts using acoustic volumeter
IMEKO 20th TC3, 3rd TC16 and 1st TC22 International Conference Cultivating metrological knowledge 27th to 30th November, 2007. Merida, Mexico. Automated volume measurement for weihts using acoustic volumeter
More informationMASS DETERMINATION OF SILICON SPHERES USED FOR THE AVOGADRO PROJECT
MASS DETERMINATION OF SILICON SPHERES USED FOR THE AVOGADRO PROJECT Michael Borys, Michael Gläser, Michael Mecke Physikalisch-Technische Bundesanstalt (PTB), Germany ABSTRACT Spheres made of a silicon
More informationModelling of a dynamic torque calibration device and determination of model parameters
ACTA IMEKO June 2014, Volume 3, Number 2, 14 18 www.imeko.org Modelling of a dynamic torque calibration device and determination of model parameters Leonard Klaus, Thomas Bruns, Michael Kobusch Physikalisch-Technische
More informationAir Density Determination Using 1 kg Buoyancy Mass Comparison(III)
Air Density Determination Using 1 kg Buoyancy Mass Comparison(III) Jin-Wan CHUNG, Kyung-Ho CHANG, Woo-Gab LEE, Kwang-Pyo KIM Division of Physical Metrology, Korea Research Institute of Standards and Science(KRISS)
More informationReduction of the effect of floor vibrations in a checkweigher using an electromagnetic force balance system
ACTA IMEKO ISSN: 1 870X July 017, Volume 6 Number, 65 69 Reduction of the effect of floor vibrations in a checkweigher using an electromagnetic force balance system Yuji Yamakawa 1, Takanori Yamazaki 1
More informationForce Key Comparison CCM.F-K1.a and CCM.F-K1.b 5 kn and 10 kn. Aimo Pusa MIKES Finland
Force Key Comparison CCM.F-K1.a and CCM.F-K1.b 5 kn and 10 kn Aimo Pusa 09.02.2009 MIKES Finland 2 Content Page Content 3 Foreword 4 Chapter 1 1.1 General 6 1.2 Characteristics of the transducers 8 1.3
More informationFABRICATION, TESTING AND CALIBRATION OF TWO DIRECTIONAL FORCE SENSOR
FABRICATION, TESTING AND CALIBRATION OF TWO DIRECTIONAL FORCE SENSOR Kuruva Veerakantha 1, G.Kirankumar 2 1 Assistant Professor, Mechanical Engineering, NNRG, Telangana, India 2 Assistant Professor, Mechanical
More informationMODEL-BASED ANALYSIS OF THE DYNAMIC BEHAVIOUR OF A 250 KN SHOCK FORCE CALIBRATION DEVICE
XX IMEKO World Congress Metrology for Green Growth September 9 14, 212, Busan, Republic of Korea MODEL-BASED ANALYSIS OF THE DYNAMIC BEHAVIOUR OF A 25 KN SHOCK FORCE CALIBRATION DEVICE Michael Kobusch,
More informationContinuous Mass Measurement in Checkweighers and Conveyor Belt Scales
Continuous Mass Measurement in Checkweighers and Conveyor Belt Scales Takanori YAMAZAKI*, Yoshiharu SAKURAI**, Hideo OHNISHI*** Masaaki KOBAYASHI***, Shigeru KUROSU** *Tokyo Metropolitan College of Technology,
More informationFORCE STANDARDS COMPARISON BETWEEN PTB (GERMANY) AND CENAM (MEXICO).
FORCE STANDARDS COMPARISON BETWEEN PTB (GERMANY) AND CENAM (MEXICO). Jorge C. Torres-Guzmán*, Amritlal Sawla**, Daniel Ramírez-Ahedo* * Centro Nacional de Metrología, México. **Physikalisch-Technische
More informationAXISYMMETRICAL ELASTIC ELEMENTS FOR VERY LARGE FORCE TRANSDUCERS
ABSTRACT AXISYMMETRICAL ELASTIC ELEMENTS FOR VERY LARGE FORCE TRANSDUCERS Dan-Mihai Stefanescu, Dae-Im Kang Korea Research Institute of Standards and Science (KRISS) - Division of Physical Metrology, Daejeon,
More informationLoadcell Calibration - Evaluation of Uncertainties
Loadcell Calibration - Evaluation of Uncertainties This document is a revision of the evaluation issued in June 2015. Novatech s calibration laboratory is not UKAS accredited due to the high number of
More informationMass determination of 1 kg silicon spheres for Avogadro project
IMEKO 20 th TC3, 3 rd TC16 and 1 st TC22 International Conference Cultivating metrological knowledge 27 th to 30 th November, 2007. Merida, Mexico. Mass determination of 1 kg silicon spheres for Avogadro
More informationFinal Report on CIPM key comparison of multiples and submultiples of the kilogram (CCM.M-K2)
1 Final Report on CIPM key comparison of multiples and submultiples of the kilogram (CCM.M-K) 1. Introduction L.O. Becerra 1, W. Bich, N. Bignell 3, G.D. Chapman 4, J.W. Chung 5 S. Davidson 6, M. Gläser
More informationMorehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web: sales:
Morehouse 1 Morehouse Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA 17403 PH: 717-843-0081 web: www.mhforce.com sales: edlane@mhforce.com 2 This presentation will cover the calibration
More informationMEASUREMENT UNCERTAINTY OF ROTATING TORQUE TRANSDUCERS WHEN USED IN PARTIAL LOAD RANGES
XVIII IMEKO WORLD CONGRESS Metrology for a Sustainable Development September, 17, 006, Rio de Janeiro, Brazil MEASUREMENT UNCERTAINTY OF ROTATING TORQUE TRANSDUCERS WHEN USED IN PARTIAL LOAD RANGES Georg
More informationA Collaboration Between Ten National Measurement Institutes To Measure The Mass Of Two One Kilogram Mass Standards
NPL REPORT CMAM 36(a) A Collaboration Between Ten National Measurement Institutes To Measure The Mass Of Two One Kilogram Mass Standards This Report Supersedes NPL Report CMAM 36 I Severn SEPTEMBER 2000
More informationThe activities of micro-force measurement below 10 mn in Center for Measurement Standards
The activities of micro-force measurement below 10 mn in Center for Measurement Standards Sheng-Jui Chen and Sheau-Shi Pan With contribution from : Ya-Ko Chih, Chung-Lin Wu, Fu-Lung Pan, Chin-Fen Tuan
More informationTechnical Note Development of a New, High Sensitivity 2000 kg Mechanical Balance
Technical Note Development of a New, High Sensitivity 2000 kg Mechanical Balance Jian Wang Division of Mechanics and Acoustics, National Institute of Metrology, Beijing 100029, China; wjian@nim.ac.cn;
More informationTEMPERATURE AND HUMIDITY DEPENDENCE ON STABILITY OF TORQUE MEASURING DEVICES Tassanai Sanponpute and Nittaya Arksonnarong
IMEKO 22 nd TC3, 15 th TC5 and 3 rd TC22 International Conferences 3 to 5 February, 2014, Cape Town, Republic of South Africa TEMPERATURE AND HUMIDITY DEPENDENCE ON STABILITY OF TORQUE MEASURING DEVICES
More informationType UB1 Load Cell. Option Stainless steel cable gland
Type UB1 Load Cell IP68 APPROVED Product Description Type UB1 is a stainless steel universal load cell which allows for tension and compression loading. Its complete hermetic sealing makes it suitable
More informationDesign of a compact six-component force and moment sensor for aerodynamic testing
Design of a compact six-component force and moment sensor for aerodynamic testing Marin SANDU*, Adriana SANDU*, Georgeta IONAŞCU* *Corresponding author POLITEHNICA University of Bucharest, Splaiul Independenţei
More information(Refer Slide Time 1:33)
Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras Module - 4 Lecture - 45 Measurement of Force This will be lecture
More informationThe calibration system of force measurement devices - conceptions and principles
The calibration system of force measurement devices - conceptions and principles ABSTACT Eng. Boris Katz, Liron Anavy, Itamar Nehary Quality Control Center Hazorea (QCC Hazorea), Israel Developed, put
More informationAPPLICATION OF A SCANNING VIBROMETER FOR THE PERIODIC CALIBRATION OF FORCE TRANSDUCERS
XX IMEKO World Congress Metrology or Green Growth September 9 14, 01, Busan, Republic o Korea APPLICATION OF A SCANNING VIBROMETER FOR THE PERIODIC CALIBRATION OF FORCE TRANSDUCERS Christian Schlegel,
More informationINVESTIGATION OF TRANSFER STANDARDS IN THE HIGHEST RANGE UP TO 50 MN WITHIN EMRP PROJECT SIB 63 Falk Tegtmeier 1, Michael Wagner 2, Rolf Kumme 3
XXI IMEKO World Congress Measurement in Research and Industry August 30 September 4, 2015, Prague, Czech Republic INVESTIGATION OF TRANSFER STANDARDS IN THE HIGHEST RANGE UP TO 50 MN WITHIN EMRP PROJECT
More informationCalibration Traceability Guidelines
Calibration Traceability Guidelines Check the website of accrediting bodies for the accredited laboratories individual scope of accreditation www.a2la.org ts.nist.gov/standards/accreditation/index.cfm
More informationT e c h n i c a l L e x i c o n
T e c h n i c a l L e x i c o n T e r m s f r o m F o r c e a n d t o r q u e m e a s u r e m e n t t e c h n o l o g y a n d G T M d a t a s h e e t s Technisches Lexikon (eng.) 16/10/14 Introduction
More informationTransparent Stretchable Self-Powered Patchable. Sensor Platform with Ultrasensitive Recognition
Supporting Information Transparent Stretchable Self-Powered Patchable Sensor Platform with Ultrasensitive Recognition of Human Activities Byeong-Ung Hwang,, Ju-Hyuck Lee,, Tran Quang Trung,, Eun Roh, Do-Il
More information20th IMEKO TC3 International Conference on Measurement of Force, Mass and Torque 2007
20th IMEKO TC3 International Conference on Measurement of Force, Mass and Torque 2007 Merida, Mexico 27 November-1 December 2007 ISBN: 978-1-61567-634-7 Printed from e-media with permission by: Curran
More informationVALLIAMMAI ENGINEERING COLLEGE
VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur 603 203 DEPARTMENT OF ELECTRONICS AND INSTRUMENTATION ENGINEERING QUESTION BANK V SEMESTER EI6502 -INDUSTRIAL INSTRUMENTATION I Regulation 2013
More informationSeismic Base Isolation Analysis for the Control of Structural Nonlinear Vibration
Seismic Base Isolation Analysis for the Control of Structural Nonlinear Vibration L. Y. Li & J. P. Ou Faculty of Infrastructure Engineering, Dalian University of Technology, Dalian, 11624, China SUMMARY:
More informationCWR track vibration characteristics varying with the change of supporting condition
Computers in Railways XIII 745 CWR track vibration characteristics varying with the change of supporting condition L. Li & Y. Luo Railway and Urban Mass Transit Research Institute, Tongji University, China
More informationStrength Study of Spiral Flexure Spring of Stirling Cryocooler
Sensors & Transducers 2013 by IFSA http://www.sensorsportal.com Strength Study of Spiral of Stirling Cryocooler WANG Wen-Rui, NIE Shuai, ZHANG Jia-Ming School of Mechanical Engineering, University of Science
More informationGuide to the Uncertainty of Force Measurement
April 1999 Guide to the Uncertainty of Force Measurement Liam Maybank, Andy Knott, and David Elkington Centre for Mechanical and Acoustical Metrology National Physical Laboratory Queens Road Teddington
More informationPROGRESS IN DEVELOPMENT OF CALIBRATION SYSTEMS FOR ANGULAR VIBRATION PICKUPS
XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal PROGRESS IN DEVELOPMENT OF CALIBRATION SYSTEMS FOR ANGULAR VIBRATION PICKUPS Wan-Sup Cheung 1 and Troben
More informationreports in applied measurement
reports in applied measurement ram reports in applied measurement A new transducer for directly measuring the forces and moments which a skier transfers to the skis F Z M Z A. Freddi, G. Olmi, D. Croccolo
More informationFundamentals of Low Intensity Shock Calibration
Low intensity shock metrology for safety related applications Fundamentals of Low Intensity Shock Calibration Speaker : Yu-Chung Huang Date : 2014.08.20 Center for Measurement Standards/ Industrial Technology
More informationHigh Precision Mass Measurement in Automation Tatjana Ivanova 1, Jānis Rudzītis 2
Solid State Phenomena Vol. 164 (2010) pp 19-24 Online available since 2010/Jun/30 at www.scientific.net (2010) Trans Tech Publications, Switzerland doi:10.4028/www.scientific.net/ssp.164.19 High Precision
More informationGlossary Innovative Measurement Solutions
Glossary GLOSSARY OF TERMS FOR TRANSDUCERS, LOAD CELLS AND WEIGH MODULES This purpose of this document is to provide a comprehensive, alphabetical list of terms and definitions commonly employed in the
More informationA Study on the Tube of Integral Propeller Shaft for the Rear-wheel Drive Automobile Using Carbon Composite Fiber
A Study on the Tube of Integral Propeller Shaft for the Rear-wheel Drive Automobile Using Carbon Composite Fiber Kibong Han Mechatronics Department, Jungwon University, 85 Munmu-ro, Goesan-gun, South Korea.
More informationINVESTIGATION OF THE CALIBRATION CAPABILITIES OF A 1 KN M AND 10 KN M REFERENCE CALIBRATION MACHINE
IMEKO 23 rd TC3, 13 th TC5 and 4 th TC22 International Conference 30 May to 1 June, 2017, Helsinki, Finland INVESTIGATION OF THE CALIBRATION CAPABILITIES OF A 1 KN M AND 10 KN M REFERENCE CALIBRATION MACHINE
More informationFlowchart for the extraordinary calibrations prior to the redefinition of the kilogram. (BIPM proposal)
Flowchart for the extraordinary calibrations prior to the redefinition of the kilogram (BIPM proposal) Pauline Barat Michael Stock Alain Picard Richard Davis 1 CIPM informed of intention to use IPK Document
More informationFlexural properties of polymers
A2 _EN BUDAPEST UNIVERSITY OF TECHNOLOGY AND ECONOMICS FACULTY OF MECHANICAL ENGINEERING DEPARTMENT OF POLYMER ENGINEERING Flexural properties of polymers BENDING TEST OF CHECK THE VALIDITY OF NOTE ON
More informationWater Vapour Effects in Mass Measurement
Water Vapour Effects in Mass Measurement N.-E. Khélifa To cite this version: N.-E. Khélifa. Water Vapour Effects in Mass Measurement. Measurement. Water Vapour Effects in Mass Measurement, May 2007, Smolenice,
More informationForce Key Comparison APMP.M.F-K2.a and APMP.M.F-K2.b (50 kn and 100 kn) Final Report 6 August Pilot: KRISS, Republic of Korea Yon-Kyu Park
Force Key Comparison APMP.M.F-K2.a and APMP.M.F-K2.b (50 kn and 100 kn) Final Report 6 August 2018 Pilot: KRISS, Republic of Korea Yon-Kyu Park Muktar Sawi (NMIM) Seif M. Osman (NIS) S.S.K.Titus (NPLI)
More informationSPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Force Proving Instruments
NABL 122-06 NATIONAL ACCREDITATION BOARD FOR TESTING AND CALIBRATION LABORATORIES SPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Force Proving Instruments Reviewed by MASTER
More informationTC-Chair Annual Report 2008/2009 TC-M
TC-Chair Annual Report 2008/2009 TC-M 20 May 2009 1. General Aspects The Contact Persons meeting was held in Malta at the beginning of March and was again very successful with over 70 participants form
More informationFinal Report on the Torque Key Comparison CCM.T-K2 Measurand Torque: 0 kn m, 10 kn m, 20 kn m Dirk Röske 1), Koji Ogushi 2)
Final Report on the Torque Key Comparison CCM.T-K Measurand Torque: kn m, 1 kn m, kn m Dirk Röske 1), Koji Ogushi ) 1) ) Dirk RÖSKE Physikalisch-Technische Bundesanstalt Department 1. Solid Mechanics orking
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 MTS FIELD SERVICE 14000 Technology Drive Eden Prairie, MN 55344 Hugh Casper Phone: 518 852 3977 CALIBRATION Valid To: September 30,
More information50kNm TORQUE STANDARD MACHINE
50kNm TORQUE STANDARD MACHINE Shang Wei Lu, Li Tao, Cheng Yong Pei, Wang Yan, Qian Zhao Jun Shanghai Marine Equipment Research Institute, Shanghai, China ABSTRACT The paper introduces the working principle
More informationFinal report Comparison Identifier: APMP.SIM.M.P-K1c Other designation: NIST-NPLI/Pressure/2
Final report Comparison Identifier: APMP.SIM.M.P-K1c Other designation: NIST-NPLI/Pressure/2 Bilateral comparison between NIST (USA) and NPLI (India) in the pneumatic pressure region 0.4 MPa to 4.0 MPa
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:. Av. Rio Consulado # 2614, Col. San Juan de Aragón
More informationTHE UNCERTAINTY OF MEASUREMENT IN CALIBRATION USING A COMPARISON FORCE STANDARD MACHINE
THE UNCERTAINTY OF MEASUREMENT IN CALIBRATION USING A COMPARISON FORCE STANDARD MACHINE Adrian Gherasimov 1, Eugen Ghita 1 Romanian Bureau of Legal Metrology, Force Laboratory Timisoara, Romania POLITEHICA
More informationDEVELOPMENT OF ANGULAR VELOCITY CALIBRATION FACILITY USING SELF-CALIBRATABLE ROTARY ENCODER
IMEKO 22 nd TC3, 12 th TC5 and 3 rd TC22 International Conferences 3 to 5 February, 2014, Cape Town, Republic of South Africa DEVELOPMENT OF ANGULAR VELOCITY CALIBRATION FACILITY USING SELF-CALIBRATABLE
More informationCharacterization of Force Transducers for Dynamic Measurements
Characterization of Force Transducers for Dynamic Measurements Michael Kobusch * 1 Introduction The measurement of time-dependent forces has gained particular importance over the past years. In this context,
More informationISO 376 Calibration Uncertainty C. Ferrero
ISO 376 Calibration Uncertainty C. Ferrero For instruments classified for interpolation, the calibration uncertainty is the uncertainty associated with using the interpolation equation to calculate a single
More informationTHE S-S CURVE APPROXIMATION FOR GFRP TENSILE SPECIMEN BY USING INVERSE METHOD AND OPTIMIZATION
THE S-S CURVE APPROXIMATION FOR GFRP TENSILE SPECIMEN BY USING INVERSE METHOD AND OPTIMIZATION D. S. Shin and E. S. Jeon Department of Mechanical Engineering, Kongju National University, Korea E-Mail:
More informationForce Sensors. What is a force sensor?
orce Sensors What is a force sensor? In physics, the definition of force is any agent that causes a mass to move. When you push an object, say a toy wagon, you re applying a force to make the wagon roll.
More informationUpgrade of 5m-Bench System for Traceable Measurements of Tapes and Rules at SASO-NMCC Dimensional Laboratory
Upgrade of 5m-Bench System for Traceable Measurements of Tapes and Rules at SASO-NMCC Dimensional Laboratory Bülent ÖZGÜR 1,*, Okhan GANİOĞLU 1, Nasser Al-Qahtani 2, Faisal Al-Qahtani 2 1 TÜBİTAK, National
More informationSpecial edition paper
Development of New Aseismatic Structure Using Escalators Kazunori Sasaki* Atsushi Hayashi* Hajime Yoshida** Toru Masuda* Aseismatic reinforcement work is often carried out in parallel with improvement
More informationLOAD CELL DESIGN USING FIBER BRAGG GRATING SENSORS
Advanced Materials Development and Performance (AMDP2011) International Journal of Modern Physics: Conference Series Vol. 6 (2012) 203-208 World Scientific Publishing Company DOI: 10.1142/S2010194512003182
More informationReliable Test Results
Intelligent testing Johannes J.Bührle - Agenda Reliable test results are a fundamental and highly topical aspect of materials testing. Using suitable examples we would like to show you how we view this
More informationSEISMIC RESPONSE EVALUATION OF AN RC BEARING WALL BY DISPLACEMENT-BASED APPROACH
3 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August -, 4 Paper No. 49 SEISMIC RESPONSE EVALUATION OF AN RC BEARING WALL BY DISPLACEMENT-BASED APPROACH Chang-Hun HYUN, Sanghyun
More informationFatigue failure mechanisms of thin-walled hybrid plate girders
Fatigue failure mechanisms of thin-walled hybrid plate girders Pavol Juhás1,* 1Institute of Technology and Business in České Budějovice, Department of Civil Engineering, Okružní 517/10, 37001 České Budějovice,
More informationINSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad
INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad -500 043 MECHANICAL ENGINEERING TUTORIAL QUESTION BANK Name : INSTRUMENTATION AND CONTROL SYSTEMS Code : A70343 Class : IV B. Tech
More informationOIML D 28 DOCUMENT. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Conventional value of the result of weighing in air
INTERNATIONAL DOCUMENT OIML D 28 Edition 2004 (E) Conventional value of the result of weighing in air Valeur conventionnelle du résultat des pesées dans l'air OIML D 28 Edition 2004 (E) ORGANISATION INTERNATIONALE
More informationLoad Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B
Force Load Washers for Forces of 7,5... 1 200 kn Type 9001A... 9071A 9081B, 9091B 1-component force sensor for measuring dynamic and quasistatic forces in z direction. F z Calibrated measuring range 100
More informationfive Mechanics of Materials 1 ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture
ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture five mechanics www.carttalk.com of materials Mechanics of Materials 1 Mechanics of Materials MECHANICS MATERIALS
More informationSupplementary comparison SIM.M.FF-S12. Final Report for Volume of Liquids at 20 L
Supplementary comparison SIM.M.FF-S12 Final Report for Volume of Liquids at 20 L Pilot: M. Maldonado (CENAM, Mexico) mmaldona@cenam.mx km 4.5 Carretera a los Cués, El Marqués, Qro 76241, Mexico Participants:
More informationSet No. 1 1. (a) Differentiate among Desired, Modifying and Interfering inputs. (b) How do you eliminate the effects of interfering and modifying inputs? Explain 2. (a) Define the term Transducer and explain
More informationDESIGN AND SIMULATION OF UNDER WATER ACOUSTIC MEMS SENSOR
DESIGN AND SIMULATION OF UNDER WATER ACOUSTIC MEMS SENSOR Smitha G Prabhu 1, Nagabhushana S *2 1 Dept. Of Electronics and communication, Center for Nano Materials and MEMS, 2 Dept. of Electronics and Communication,
More informationFuzzy logic based control design for active dancer closed loop web tension control
Fuzzy logic based control design for active dancer closed loop web tension control GANESHTHANGARAJ PONNIAH*, MUHAMMAD ZUBAIR * YANG- HOI DOH** and KYUNG-HYUN CHOI* *Department of Mechatronics engineering,
More informationASSOCIATE DEGREE IN ENGINEERING EXAMINATIONS. SEMESTER 2 May 2013
ASSOCIATE DEGREE IN ENGINEERING EXAMINATIONS SEMESTER 2 May 2013 COURSE NAME: CODE: Mechanical Engineering Science [8 CHARACTER COURSE CODE] GROUP: AD-ENG 1 DATE: TIME: DURATION: "[EXAM DATE]" "[TIME OF
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More information