IMKO TC3/APMF '98. Proceedings of. Taejon, Republic. Organized by Korea Research Institute of Standards and Science (KRISS)

Size: px
Start display at page:

Download "IMKO TC3/APMF '98. Proceedings of. Taejon, Republic. Organized by Korea Research Institute of Standards and Science (KRISS)"

Transcription

1 IMKO TC3/APMF '98 Proceedings of the 16th International Conference on Force, Mass and Torque Measurements in Parallel with Asia-Pacific Symposium on Measurement of Mass and Force September 1998 Taejon, Republic of Korea Edited by Myung Sai Chung Organized by Korea Research Institute of Standards and Science (KRISS) Hosted by Korea Association of Standards and Testing Organizations (KASTO) Sponsored by International Measurement Confederation (IMEKO) TC3

2 Contents I Invited Lectures The activity of the Consultative Committee for the Mass and the Related Quantities - (CCM) Past, Kozo llzuka present and future 3 National standards system 13 Sekyung Lee Uncertainty in force measurement 20 Giullo Barbate I Session I. Hydraulic Force Machine and Build-up Systems Build-up system force standards in compression and in tension up to 9 MN at BNM- LNE 37 A. Gosset, P. Averlant Development and calibration of a build-up system for forces of -up P. Anderegg, W. Honegger, W. Sennhauser, R. Kumme, A. Sawla to 21 MN 45 Evaluation of the uncertainty of the hydraulic force standard machine 54 C. Shi Application of an infinite impulse response fitter for precision calibration of a build-up system in a deadweight force machine 60 Y. K. Park, D. I. Kang, B. D. Lim I Session II. Deadweight Force Machine A new automatic deadweight machine for testing weighing instruments up R. Schwartz, H. Gassmann, D. Airey, W. Baars, P. Brandes to 3 t 69 Force metrology in Italy: The new 1 MN deadweight force standard 75 C, Ferrero, C. Marinarl, E. Martino i

3 Structural and performance characteristics of newly developed 3 kn deadweight force standard machine 83 T. Tojo ln-srtu calibration of a dead-weight force machine 89 J. Man, D. Tyrrell, D. Groeneveld Determination of the masses' value and uncertainty for the 150 kn force national standard from CENAM-Mexico 95 A. Franco P., J. Mendoza I., J. C. Torres G. I Session III. Force Transducers and Indicator Design and evaluation of a compact size six-component loadcell 105 J. W. Joo, K. S. Na, D. I. Kang Load application and measuring behaviour of a bending ring force transfer standard 112 T. Allgeler, H. Gassmann, A. Sawla Three-axis strain gauged force transducers 118 D. M. Stefanescu, T. Manescu Analysis of gyroscopic sensor applied to force measurement - Vectorial measurement of horizontal force 128 M. Kasahara, S. Kurosu, M. Adachi, K. Kamlmura Multi-channel high-precision measuring systems 137 M. Kreuzer A fast precision-adc with integrated telemetry for extremely stiff torque sensors 146 U. Bernhardt, K. Horn - Strain gauge based load cell The possibility of software creep error compensation D. Kovacevic, S. Skundrlc, S. Mlklclc, B. Dimltrljevlc 154 I Session IV. Moss (I) Using a 1 kg mass comparator to calibrate submuwples to 1 g 163 R. S. Davis, M. J. Coarasa Loaded strips as low-loss torsion elements 168 J. W. Chung, R, S. Davis Contamination on TiN and BN thin films deposited on stainless steel by IBAD 173 S, K. Lee, J. Y. Llm, Y. H. Shin, S. S. Hong, K. H. Chung ii

4 B Session V. Mass (II) Carbon dioxide determination for high accuracy weighings 183 M. Plassa, M. Mosca, M. Sega Further investigations on cleaning-washing of platinum-iridium kilograms 192 W. Blch, V. De Glronimo A weight handler for a 5 g mass comparator 198 H. Kajastie, J. Manninen, K. Riski, H. Rossi Determination of waiting time of cleaned weights before calibration 203 S. Kacmaz, V. Ciftgl I Session VI. Mass (III) A versatile automatic weight changer for mass comparators 209 M. T. Clarkson, C. M. Sutton, D. G. Jack Research on our OIML class E-, 1 g to 20 kg nonmagnetic stainless steel weight set 216 R. Sun, H. Yao, L. Wang, N. Mo, Y. Pei Weight calibration by mass comparators with automatic weight exchanging mechanism M. Uekl, Y. Nezu, S. Mlzushima, A. Oolwa 220 On the scale using a circumferentially fixed disc 227 Y. Yoshlmura, T. Tsutsumi I Session VII. Mass and Density In situ direct determination of air density using Pt-lr and St. St. standards 233 W. G. Lee, J. Y. Do, J. W. Chung Air density determination using 1 kg buoyancy mass comparison (l) 237 J. Y. Do, J. W. Chung, K. H. Chang Application of statistics to oil density measurement 242 K. H. Chang, Joel T. Park I Session VIII. Force Calibrations and Measurements The possibility of force transducer calibration using with lower capacity force standard machines 255 S. Fank, H. Parlakturk iii

5 Application of the continuous calibration procedure for industrial standard calibration of torque-and force-transducers 260 D. Kenzler Dental implants: in vivo and in vitro measurements of functional loading 264 K. Haselhuhn, Th. Bruns, G. Schrobsdorff, 0. Kranz, L. W. R. Kobes, M. Peters I Session IX. Torque Measurements Calibration of torque measuring devices - D. Peschel, A. Bruge step-by-step or continuous procedure 275 Investigation of the influence of disturbing components on the torque measurement D. Roske 280 A research on the dynamic performance of torquemeter and its calibration method 286 W. Shang, Y. Wang, T. Lee, M. Lin Evaluation of the uncertainty of torque for the dead-weight torque standard machine Y. Zhang, W. Shang 290 Development of high-qualified transfer transducer for torque and testing the calibration device 294 A. Pusa I Session X. Dynamic Forces and Mass Novel method of weighing data-processing under floor vibration 303 T. Ono, Y. FuJIoka, J. Sun Quasistatic and dynamic investigation methods of piezoelectric force measuring devices O. Mack, R. Kumme 310 A mass-estimation method with linear regression models for in-motion vehicles using axle weighing system 321 T. Ono, K. Fukuda, K. Yoshlda, H. Tottorl Load measurement by two freedom dynamic crane scale 329 L. Chen, N. Aoshima Dynamic model on force feedback system for nano-newton force measurement 338 N. Kato, H. Klkuta, T. Matumoto, K. Iwata Perspective on APMF 346 L. Wang iv

6 1 Poster Session Force Standard Machines and Intercomparlsons Uncertainty evaluation of 2 MN hydraulic force machine through intercomparison measurement 353 D. I. Kang, H. K. Song, J. T. Lee, R. Kumme, A. Sawla IMGC-CNR and KRISS deadweight force standard machines intercomparison 358 C. Ferrero, C. Marinari, E. Martlno, D. I. Kang, G. S. Kim, H. K. Song, J. T. Lee Accreditation of a Romanian 32 MN force calibration laboratory within DKD 366 A. Marinescu, I. Dumbrava, Gh. Opran, D. Popa, A. Sawla, D. Peschel, M. Peters High accuracy technology research on the lever force standard machine 376 G. L. Wu, F. Zhao A new N range force standard systems for the force calibration laboratories 379 S. Fank Characterization of the 2 MN hydraulic force comparator machine of CEM 383 J. A. Robles Carbonell, J. A. Fernandez Garcia, J. Robles Verdecla, A. Lobo Robledo Development of a 100 kn deadweight force standard machine 389 G. S. Kim, H. K. Song, D. I. Kang, J. H. Ahn, W. S. Kim Intercomparison in tension of the large force standard machines of the BNM-LNE and PTB 395 A. Gosset, P. Averlant, A. Sawla, F. Kohler, W. Schmelter Load Cells and Applications Valuation of rolling force and torque of steel through modeling with the aid of hot compression tests 403 T. A. El-Bitar Thin load cell for weighing scales 408 C. Maeda Calibration unit for three quantities: torque, force and pressure 415 P. D. Hohmann Experiences with the new revised OIML recommendation R60 for load cells 419 B. Meaner V

7 Design of new spring type constant-force mechanisms 429 W. K. Kim, D. I. Kang, H. S. Kim, M. G. Kim Nonlinear finite element analysis according to design parameters of a column type load cell 436 C. Y. Lee, D. I. Kang Application of 3-component load cell to surface characteristics measurement system for tactile perception 442 Y. H. Kwon, D. I. Kang Torque wrench calibration according to ISO 6789 and supplements 447 D. Kenzler, D. Peschel Non-contact magnetostrictive torque sensor 450 R. Ishino Effect of floor vibration on a double-beam type loadcell scale 460 M. Nakatanl, K. Kameoka, G, Komatsu, N. Inui, K. Nalto, H. Konlshi, Y. Shlmomae Study of the inspection system for the rail load, vehicle status and running safety J. LI, M. Liu 468 Mass Standards and Applications Plasticity in weighing instruments, or others, using contact knife-bearing 477 M, Renoult Automatic 50 kg weight handler 481 T. K. Chan. K. K. Hau, C. F. Yuen Observation and analysis of linearity error for the weighing instruments 486 S. Kacmaz, M. H. Orhan, S. Fank Stability of sinkers for establishment of mass standard Y. Nezu, M. Ueki, A. Ooiwa Accurate mass measurement of two 1 kg silicon spheres(s4, S5) for the determination of the Avogadro constant 493 Y. Nezu, K. Fujil, M, Tanaka, A. Ooiwa Implementation and understanding of OIML R76 international recommendation 497 R. Chen, Y. Ru Water adsorption on the stainless steel surface studied by null ellipsometry 500 D. J. Bae, H. S. Nham, J. Y. Do vi

8 Influence of a performer on mass calibration A. Kolar, M. Grum 507 Experimental Mechanics A development of dynamometer for measurement of high-frequency cutting force 515 K. Y. Lee, J. S. Kim, D. W. Lee, M. C. Kang Strain measurement of structures by digital signal processing of a passive quadrature demodulated 3x3 fiber optic Michelson interferometric sensor 520 I. B. Kwon, M. S. Bae Effects of micro structural and mechanical factors on fatigue limit in SGI 527 M. G. Kim, J. H. Kim Index 535 vii

Comparison between the CENAM (Mexico) 150 kn and the INRiM (Italy) 1 MN force standard machines

Comparison between the CENAM (Mexico) 150 kn and the INRiM (Italy) 1 MN force standard machines IMEKO 20 th TC3, 3 rd TC16 and 1 st TC22 International Conference Cultivating metrological knowledge 27 th to 30 th November, 2007. Merida, Mexico. Comparison between the CENAM (Mexico) 150 kn and the

More information

EVALUATION OF STATIC AND DYNAMIC PARASSITIC COMPONENTS ON THE INRIM 1 MN PRIMARY FORCE STANDARD MACHINE BY MEANS THE 500 kn SIX-COMPONENT DYNAMOMETER

EVALUATION OF STATIC AND DYNAMIC PARASSITIC COMPONENTS ON THE INRIM 1 MN PRIMARY FORCE STANDARD MACHINE BY MEANS THE 500 kn SIX-COMPONENT DYNAMOMETER XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal EVALUATION OF STATIC AND DYNAMIC PARASSITIC COMPONENTS ON THE INRIM 1 MN PRIMARY FORCE STANDARD MACHINE

More information

September 17-21, 2001, Istanbul / TURKEY

September 17-21, 2001, Istanbul / TURKEY INTERNATIONAL MEASUREMENT CONFEDERATION Technical Committee TC3 on Measurement of Force, Mass and Torque Proceedings of the 17 International Conference FORCE, MASS, TORQUE AND PRESSURE MEASUREMENTS AT

More information

UNCERTAINTY IN TORQUE CALIBRATION USING VERTICAL TORQUE AXIS ARRANGEMENT AND SYMMETRICAL TWO FORCE MEASUREMENT

UNCERTAINTY IN TORQUE CALIBRATION USING VERTICAL TORQUE AXIS ARRANGEMENT AND SYMMETRICAL TWO FORCE MEASUREMENT UNCERTAINTY IN TORQUE CALIBRATION USING VERTICAL TORQUE AXIS ARRANGEMENT AND SYMMETRICAL TWO FORCE MEASUREMENT Dieter Kenzler 1, Jörg Oblasser 2, Andreas Subaric-Leitis 2 and Christian Ullner 2 1 ) SCHATZ

More information

Increased Requirements for Higher Nominal Forces, Necessities and Possibilities to Measure Them

Increased Requirements for Higher Nominal Forces, Necessities and Possibilities to Measure Them B 3.1 Increased Requirements for Higher Nominal Forces, Necessities and Possibilities to Measure Them Dr. Schäfer, André Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45, 64293 Darmstadt andre.schaefer@hbm.com

More information

PTB S 16.5 MN HYDRAULIC AMPLIFICATION MACHINE AFTER MODERNIZATION

PTB S 16.5 MN HYDRAULIC AMPLIFICATION MACHINE AFTER MODERNIZATION IMEKO 22 nd TC3, 15 th TC5 and 3 rd TC22 International Conferences 3 to 5 February, 2014, Cape Town, Republic of South Africa PTB S 16.5 MN HYDRAULIC AMPLIFICATION MACHINE AFTER MODERNIZATION R. Kumme

More information

Evaluation of Force Standard Machines by using Build-up System

Evaluation of Force Standard Machines by using Build-up System Evaluation of Force Standard Machines by using Build-up System TC3 Round Table Nov. 24, 2010 Y.-K. Park and D.-I. Kang Contents Introduction Basic theory Application examples Dynamic behavior of deadweight

More information

XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal

XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 9, Lisbon, Portugal IMPROVEMENT OF METROLOGICAL CHARACTERISTICS OF INTI S 11 kn FORCE STANDARD MACHINE BY USING THE CENAM S SIX-COMPONENT

More information

Force/Torque measuring facility for friction coefficient and multicomponent

Force/Torque measuring facility for friction coefficient and multicomponent DOI 10.516/sensor013/A1. Force/Torque measuring facility for friction coefficient and multicomponent sensors S. Baumgarten 1, D. Röske 1, H. Kahmann 1, D. Mauersberger 1 and R. Kumme 1 1 Physikalisch-Technische

More information

THE NEW 1.1 MN m TORQUE STANDARD MACHINE OF THE PTB BRAUNSCHWEIG/GERMANY

THE NEW 1.1 MN m TORQUE STANDARD MACHINE OF THE PTB BRAUNSCHWEIG/GERMANY THE NEW 1.1 MN m TORQUE STANDARD MACHINE OF THE PTB BRAUNSCHWEIG/GERMANY D. Peschel 1, D. Mauersberger 1, D. Schwind 2, U. Kolwinski 2 1 Solid mechanics department, PTB, Germany 2 Gassmann Theiss Messtechnik

More information

Certification of a High Capacity Force Machine for Testing of Load Cells According to OIML R60

Certification of a High Capacity Force Machine for Testing of Load Cells According to OIML R60 Certification of a High Capacity Force Machine for Testing of Load Cells According to OIML R60 Bernd Meißner Physikalisch-Technische Bundesanstalt Weighing Instruments Laboratory Braunschweig Abstract

More information

COMPLETION AND MEASUREMENT UNCERTAINTY BUDGET OF THE MULTI-COMPONENT MEASURING DEVISE FOR FORCE UP TO 1 MN AND TORQUE UP TO 2 KN M

COMPLETION AND MEASUREMENT UNCERTAINTY BUDGET OF THE MULTI-COMPONENT MEASURING DEVISE FOR FORCE UP TO 1 MN AND TORQUE UP TO 2 KN M XXI IMEKO World Congress Measurement in Research and Industry August 30 September 4, 2015, Prague, Czech Republic COMPLETION AND MEASUREMENT UNCERTAINTY BUDGET OF THE MULTI-COMPONENT MEASURING DEVISE FOR

More information

FEEDBACK CONTROLLED DEADWEIGHT MACHINE

FEEDBACK CONTROLLED DEADWEIGHT MACHINE FEEDBACK CONTROLLED DEADWEIGHT MACHINE G. Barbato 1, S. Desogus 2, A. Germak 2 and M. Vattasso 3 1 DSPEA, Politecnico di Torino, C.so Duca degli Abruzzi 24, 10129 Torino, Italy 2 Istituto di Metrologia

More information

Investigation of Piezoelectric Force Measuring Devices in Force Calibration and Force. Standard Machines

Investigation of Piezoelectric Force Measuring Devices in Force Calibration and Force. Standard Machines Proceedings of the 17 th International Conference on Force, Mass, Torque and Pressure Measurements, Investigation of Piezoelectric Force Measuring Devices in Force Calibration and Force Standard Machines

More information

METHODS TO CONFIRM THE MEASUREMENT CAPABILITY OF THE FORCE STANDARD MACHINES AFTER REINSTALLATION

METHODS TO CONFIRM THE MEASUREMENT CAPABILITY OF THE FORCE STANDARD MACHINES AFTER REINSTALLATION IMEKO 22 nd TC3, 12 th TC5 and 3 rd TC22 International Conferences 3 to 5 February, 2014, Cape Town, Republic of South Africa METHODS TO CONFIRM THE MEASUREMENT CAPABILITY OF THE FORCE STANDARD MACHINES

More information

+ + ( indicator ) + (display, printer, memory)

+ + ( indicator ) + (display, printer, memory) CERTIFICATION OF STRAIN GAUGE LOAD CELL FAMILIES B. Meissner Physikalisch-Technische Bundesanstalt Weighing Instruments Laboratory 38116 Braunschweig, Germany Abstract: Testing and certification of load

More information

Multi-Capacity Load Cell Concept

Multi-Capacity Load Cell Concept Sensors & Transducers 4 by IFSA Publishing, S. L. http://www.sensorsportal.com Multi-Capacity Load Cell Concept Seif. M. OSMAN, Ebtisam H. HASAN, H. M. EL-HAKEEM, R. M. RASHAD, F. KOUTA National Institute

More information

Foundations of Ultraprecision Mechanism Design

Foundations of Ultraprecision Mechanism Design Foundations of Ultraprecision Mechanism Design S.T. Smith University of North Carolina at Charlotte, USA and D.G. Chetwynd University of Warwick, UK GORDON AND BREACH SCIENCE PUBLISHERS Switzerland Australia

More information

Uncertainty of Calibration. Results in Force Measurements

Uncertainty of Calibration. Results in Force Measurements Publication Reference EAL-G Uncertainty of Calibration Results in Force Measurements PURPOSE This document has been produced to improve the harmonization in determination of uncertainties in force measurements.

More information

18th IMEKO TC3 Conference on Force, Mass and Torque 2002

18th IMEKO TC3 Conference on Force, Mass and Torque 2002 18th IMEKO TC3 Conference on Force, Mass and Torque 2002 Joint International Conference on Force, Mass, Torque, Hardness and Civil Engineering Metrology in the Age of Globalization Celle, Germany 24 26

More information

FORCE NATIONAL STANDARDS COMPARISON BETWEEN CENAM/MEXICO AND NIM/CHINA

FORCE NATIONAL STANDARDS COMPARISON BETWEEN CENAM/MEXICO AND NIM/CHINA FORCE NATIONAL STANDARDS COMPARISON BETWEEN CENAM/MEXICO AND NIM/CHINA Qingzhong Li *, Jorge C. Torres G.**, Daniel A. Ramírez A.** *National Institute of Metrology (NIM) Beijing, 100013, China Tel/fax:

More information

EVALUATION OF ADSORPTION EFFECT BY USING SILICON SPHERE AND SILICON SURFACE ARTEFACTS

EVALUATION OF ADSORPTION EFFECT BY USING SILICON SPHERE AND SILICON SURFACE ARTEFACTS XVIII IMEKO WORLD CONGRESS Metrology for a Sustainable Development September, 17 22, 2006, Rio de Janeiro, Brazil EVALUATION OF ADSORPTION EFFECT BY USING SILICON SPHERE AND SILICON SURFACE ARTEFACTS Jin

More information

DESIGN, DEVELOPMENT, AND COMMISSIONING OF A 120 kn DEADWEIGHT FORCE STANDARD MACHINE

DESIGN, DEVELOPMENT, AND COMMISSIONING OF A 120 kn DEADWEIGHT FORCE STANDARD MACHINE DESIGN, DEVELOPMENT, AND COMMISSIONING OF A 120 kn DEADWEIGHT FORCE STANDARD MACHINE Andy Knott National Physical Laboratory, United Kingdom ABSTRACT This paper describes the development of a 120 kn deadweight

More information

Concept and setup of a multi-component facility for force and torque in the range of 1 MN and 2 kn m

Concept and setup of a multi-component facility for force and torque in the range of 1 MN and 2 kn m CT IMEKO June 2014, Volume 3, Number 2, 39 43 www.imeko.org Concept and setup of a multi-component facility for force and torque in the range of 1 MN and 2 kn m Sebastian aumgarten, Dirk Röske, Holger

More information

INVESTIGATION OF IMPACT HAMMER CALIBRATIONS

INVESTIGATION OF IMPACT HAMMER CALIBRATIONS IMEKO 23 rd TC3, 13 th TC5 and 4 th TC22 International Conference 30 May to 1 June, 2017, Helsinki, Finland INVESTIGATION OF IMPACT HAMMER CALIBRATIONS M. Kobusch 1, L. Klaus 1, and L. Muñiz Mendoza 2

More information

Automated volume measurement for weihts using acoustic volumeter

Automated volume measurement for weihts using acoustic volumeter IMEKO 20th TC3, 3rd TC16 and 1st TC22 International Conference Cultivating metrological knowledge 27th to 30th November, 2007. Merida, Mexico. Automated volume measurement for weihts using acoustic volumeter

More information

MASS DETERMINATION OF SILICON SPHERES USED FOR THE AVOGADRO PROJECT

MASS DETERMINATION OF SILICON SPHERES USED FOR THE AVOGADRO PROJECT MASS DETERMINATION OF SILICON SPHERES USED FOR THE AVOGADRO PROJECT Michael Borys, Michael Gläser, Michael Mecke Physikalisch-Technische Bundesanstalt (PTB), Germany ABSTRACT Spheres made of a silicon

More information

Modelling of a dynamic torque calibration device and determination of model parameters

Modelling of a dynamic torque calibration device and determination of model parameters ACTA IMEKO June 2014, Volume 3, Number 2, 14 18 www.imeko.org Modelling of a dynamic torque calibration device and determination of model parameters Leonard Klaus, Thomas Bruns, Michael Kobusch Physikalisch-Technische

More information

Air Density Determination Using 1 kg Buoyancy Mass Comparison(III)

Air Density Determination Using 1 kg Buoyancy Mass Comparison(III) Air Density Determination Using 1 kg Buoyancy Mass Comparison(III) Jin-Wan CHUNG, Kyung-Ho CHANG, Woo-Gab LEE, Kwang-Pyo KIM Division of Physical Metrology, Korea Research Institute of Standards and Science(KRISS)

More information

Reduction of the effect of floor vibrations in a checkweigher using an electromagnetic force balance system

Reduction of the effect of floor vibrations in a checkweigher using an electromagnetic force balance system ACTA IMEKO ISSN: 1 870X July 017, Volume 6 Number, 65 69 Reduction of the effect of floor vibrations in a checkweigher using an electromagnetic force balance system Yuji Yamakawa 1, Takanori Yamazaki 1

More information

Force Key Comparison CCM.F-K1.a and CCM.F-K1.b 5 kn and 10 kn. Aimo Pusa MIKES Finland

Force Key Comparison CCM.F-K1.a and CCM.F-K1.b 5 kn and 10 kn. Aimo Pusa MIKES Finland Force Key Comparison CCM.F-K1.a and CCM.F-K1.b 5 kn and 10 kn Aimo Pusa 09.02.2009 MIKES Finland 2 Content Page Content 3 Foreword 4 Chapter 1 1.1 General 6 1.2 Characteristics of the transducers 8 1.3

More information

FABRICATION, TESTING AND CALIBRATION OF TWO DIRECTIONAL FORCE SENSOR

FABRICATION, TESTING AND CALIBRATION OF TWO DIRECTIONAL FORCE SENSOR FABRICATION, TESTING AND CALIBRATION OF TWO DIRECTIONAL FORCE SENSOR Kuruva Veerakantha 1, G.Kirankumar 2 1 Assistant Professor, Mechanical Engineering, NNRG, Telangana, India 2 Assistant Professor, Mechanical

More information

MODEL-BASED ANALYSIS OF THE DYNAMIC BEHAVIOUR OF A 250 KN SHOCK FORCE CALIBRATION DEVICE

MODEL-BASED ANALYSIS OF THE DYNAMIC BEHAVIOUR OF A 250 KN SHOCK FORCE CALIBRATION DEVICE XX IMEKO World Congress Metrology for Green Growth September 9 14, 212, Busan, Republic of Korea MODEL-BASED ANALYSIS OF THE DYNAMIC BEHAVIOUR OF A 25 KN SHOCK FORCE CALIBRATION DEVICE Michael Kobusch,

More information

Continuous Mass Measurement in Checkweighers and Conveyor Belt Scales

Continuous Mass Measurement in Checkweighers and Conveyor Belt Scales Continuous Mass Measurement in Checkweighers and Conveyor Belt Scales Takanori YAMAZAKI*, Yoshiharu SAKURAI**, Hideo OHNISHI*** Masaaki KOBAYASHI***, Shigeru KUROSU** *Tokyo Metropolitan College of Technology,

More information

FORCE STANDARDS COMPARISON BETWEEN PTB (GERMANY) AND CENAM (MEXICO).

FORCE STANDARDS COMPARISON BETWEEN PTB (GERMANY) AND CENAM (MEXICO). FORCE STANDARDS COMPARISON BETWEEN PTB (GERMANY) AND CENAM (MEXICO). Jorge C. Torres-Guzmán*, Amritlal Sawla**, Daniel Ramírez-Ahedo* * Centro Nacional de Metrología, México. **Physikalisch-Technische

More information

AXISYMMETRICAL ELASTIC ELEMENTS FOR VERY LARGE FORCE TRANSDUCERS

AXISYMMETRICAL ELASTIC ELEMENTS FOR VERY LARGE FORCE TRANSDUCERS ABSTRACT AXISYMMETRICAL ELASTIC ELEMENTS FOR VERY LARGE FORCE TRANSDUCERS Dan-Mihai Stefanescu, Dae-Im Kang Korea Research Institute of Standards and Science (KRISS) - Division of Physical Metrology, Daejeon,

More information

Loadcell Calibration - Evaluation of Uncertainties

Loadcell Calibration - Evaluation of Uncertainties Loadcell Calibration - Evaluation of Uncertainties This document is a revision of the evaluation issued in June 2015. Novatech s calibration laboratory is not UKAS accredited due to the high number of

More information

Mass determination of 1 kg silicon spheres for Avogadro project

Mass determination of 1 kg silicon spheres for Avogadro project IMEKO 20 th TC3, 3 rd TC16 and 1 st TC22 International Conference Cultivating metrological knowledge 27 th to 30 th November, 2007. Merida, Mexico. Mass determination of 1 kg silicon spheres for Avogadro

More information

Final Report on CIPM key comparison of multiples and submultiples of the kilogram (CCM.M-K2)

Final Report on CIPM key comparison of multiples and submultiples of the kilogram (CCM.M-K2) 1 Final Report on CIPM key comparison of multiples and submultiples of the kilogram (CCM.M-K) 1. Introduction L.O. Becerra 1, W. Bich, N. Bignell 3, G.D. Chapman 4, J.W. Chung 5 S. Davidson 6, M. Gläser

More information

Morehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web: sales:

Morehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web:  sales: Morehouse 1 Morehouse Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA 17403 PH: 717-843-0081 web: www.mhforce.com sales: edlane@mhforce.com 2 This presentation will cover the calibration

More information

MEASUREMENT UNCERTAINTY OF ROTATING TORQUE TRANSDUCERS WHEN USED IN PARTIAL LOAD RANGES

MEASUREMENT UNCERTAINTY OF ROTATING TORQUE TRANSDUCERS WHEN USED IN PARTIAL LOAD RANGES XVIII IMEKO WORLD CONGRESS Metrology for a Sustainable Development September, 17, 006, Rio de Janeiro, Brazil MEASUREMENT UNCERTAINTY OF ROTATING TORQUE TRANSDUCERS WHEN USED IN PARTIAL LOAD RANGES Georg

More information

A Collaboration Between Ten National Measurement Institutes To Measure The Mass Of Two One Kilogram Mass Standards

A Collaboration Between Ten National Measurement Institutes To Measure The Mass Of Two One Kilogram Mass Standards NPL REPORT CMAM 36(a) A Collaboration Between Ten National Measurement Institutes To Measure The Mass Of Two One Kilogram Mass Standards This Report Supersedes NPL Report CMAM 36 I Severn SEPTEMBER 2000

More information

The activities of micro-force measurement below 10 mn in Center for Measurement Standards

The activities of micro-force measurement below 10 mn in Center for Measurement Standards The activities of micro-force measurement below 10 mn in Center for Measurement Standards Sheng-Jui Chen and Sheau-Shi Pan With contribution from : Ya-Ko Chih, Chung-Lin Wu, Fu-Lung Pan, Chin-Fen Tuan

More information

Technical Note Development of a New, High Sensitivity 2000 kg Mechanical Balance

Technical Note Development of a New, High Sensitivity 2000 kg Mechanical Balance Technical Note Development of a New, High Sensitivity 2000 kg Mechanical Balance Jian Wang Division of Mechanics and Acoustics, National Institute of Metrology, Beijing 100029, China; wjian@nim.ac.cn;

More information

TEMPERATURE AND HUMIDITY DEPENDENCE ON STABILITY OF TORQUE MEASURING DEVICES Tassanai Sanponpute and Nittaya Arksonnarong

TEMPERATURE AND HUMIDITY DEPENDENCE ON STABILITY OF TORQUE MEASURING DEVICES Tassanai Sanponpute and Nittaya Arksonnarong IMEKO 22 nd TC3, 15 th TC5 and 3 rd TC22 International Conferences 3 to 5 February, 2014, Cape Town, Republic of South Africa TEMPERATURE AND HUMIDITY DEPENDENCE ON STABILITY OF TORQUE MEASURING DEVICES

More information

Type UB1 Load Cell. Option Stainless steel cable gland

Type UB1 Load Cell. Option Stainless steel cable gland Type UB1 Load Cell IP68 APPROVED Product Description Type UB1 is a stainless steel universal load cell which allows for tension and compression loading. Its complete hermetic sealing makes it suitable

More information

Design of a compact six-component force and moment sensor for aerodynamic testing

Design of a compact six-component force and moment sensor for aerodynamic testing Design of a compact six-component force and moment sensor for aerodynamic testing Marin SANDU*, Adriana SANDU*, Georgeta IONAŞCU* *Corresponding author POLITEHNICA University of Bucharest, Splaiul Independenţei

More information

(Refer Slide Time 1:33)

(Refer Slide Time 1:33) Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras Module - 4 Lecture - 45 Measurement of Force This will be lecture

More information

The calibration system of force measurement devices - conceptions and principles

The calibration system of force measurement devices - conceptions and principles The calibration system of force measurement devices - conceptions and principles ABSTACT Eng. Boris Katz, Liron Anavy, Itamar Nehary Quality Control Center Hazorea (QCC Hazorea), Israel Developed, put

More information

APPLICATION OF A SCANNING VIBROMETER FOR THE PERIODIC CALIBRATION OF FORCE TRANSDUCERS

APPLICATION OF A SCANNING VIBROMETER FOR THE PERIODIC CALIBRATION OF FORCE TRANSDUCERS XX IMEKO World Congress Metrology or Green Growth September 9 14, 01, Busan, Republic o Korea APPLICATION OF A SCANNING VIBROMETER FOR THE PERIODIC CALIBRATION OF FORCE TRANSDUCERS Christian Schlegel,

More information

INVESTIGATION OF TRANSFER STANDARDS IN THE HIGHEST RANGE UP TO 50 MN WITHIN EMRP PROJECT SIB 63 Falk Tegtmeier 1, Michael Wagner 2, Rolf Kumme 3

INVESTIGATION OF TRANSFER STANDARDS IN THE HIGHEST RANGE UP TO 50 MN WITHIN EMRP PROJECT SIB 63 Falk Tegtmeier 1, Michael Wagner 2, Rolf Kumme 3 XXI IMEKO World Congress Measurement in Research and Industry August 30 September 4, 2015, Prague, Czech Republic INVESTIGATION OF TRANSFER STANDARDS IN THE HIGHEST RANGE UP TO 50 MN WITHIN EMRP PROJECT

More information

Calibration Traceability Guidelines

Calibration Traceability Guidelines Calibration Traceability Guidelines Check the website of accrediting bodies for the accredited laboratories individual scope of accreditation www.a2la.org ts.nist.gov/standards/accreditation/index.cfm

More information

T e c h n i c a l L e x i c o n

T e c h n i c a l L e x i c o n T e c h n i c a l L e x i c o n T e r m s f r o m F o r c e a n d t o r q u e m e a s u r e m e n t t e c h n o l o g y a n d G T M d a t a s h e e t s Technisches Lexikon (eng.) 16/10/14 Introduction

More information

Transparent Stretchable Self-Powered Patchable. Sensor Platform with Ultrasensitive Recognition

Transparent Stretchable Self-Powered Patchable. Sensor Platform with Ultrasensitive Recognition Supporting Information Transparent Stretchable Self-Powered Patchable Sensor Platform with Ultrasensitive Recognition of Human Activities Byeong-Ung Hwang,, Ju-Hyuck Lee,, Tran Quang Trung,, Eun Roh, Do-Il

More information

20th IMEKO TC3 International Conference on Measurement of Force, Mass and Torque 2007

20th IMEKO TC3 International Conference on Measurement of Force, Mass and Torque 2007 20th IMEKO TC3 International Conference on Measurement of Force, Mass and Torque 2007 Merida, Mexico 27 November-1 December 2007 ISBN: 978-1-61567-634-7 Printed from e-media with permission by: Curran

More information

VALLIAMMAI ENGINEERING COLLEGE

VALLIAMMAI ENGINEERING COLLEGE VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur 603 203 DEPARTMENT OF ELECTRONICS AND INSTRUMENTATION ENGINEERING QUESTION BANK V SEMESTER EI6502 -INDUSTRIAL INSTRUMENTATION I Regulation 2013

More information

Seismic Base Isolation Analysis for the Control of Structural Nonlinear Vibration

Seismic Base Isolation Analysis for the Control of Structural Nonlinear Vibration Seismic Base Isolation Analysis for the Control of Structural Nonlinear Vibration L. Y. Li & J. P. Ou Faculty of Infrastructure Engineering, Dalian University of Technology, Dalian, 11624, China SUMMARY:

More information

CWR track vibration characteristics varying with the change of supporting condition

CWR track vibration characteristics varying with the change of supporting condition Computers in Railways XIII 745 CWR track vibration characteristics varying with the change of supporting condition L. Li & Y. Luo Railway and Urban Mass Transit Research Institute, Tongji University, China

More information

Strength Study of Spiral Flexure Spring of Stirling Cryocooler

Strength Study of Spiral Flexure Spring of Stirling Cryocooler Sensors & Transducers 2013 by IFSA http://www.sensorsportal.com Strength Study of Spiral of Stirling Cryocooler WANG Wen-Rui, NIE Shuai, ZHANG Jia-Ming School of Mechanical Engineering, University of Science

More information

Guide to the Uncertainty of Force Measurement

Guide to the Uncertainty of Force Measurement April 1999 Guide to the Uncertainty of Force Measurement Liam Maybank, Andy Knott, and David Elkington Centre for Mechanical and Acoustical Metrology National Physical Laboratory Queens Road Teddington

More information

PROGRESS IN DEVELOPMENT OF CALIBRATION SYSTEMS FOR ANGULAR VIBRATION PICKUPS

PROGRESS IN DEVELOPMENT OF CALIBRATION SYSTEMS FOR ANGULAR VIBRATION PICKUPS XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal PROGRESS IN DEVELOPMENT OF CALIBRATION SYSTEMS FOR ANGULAR VIBRATION PICKUPS Wan-Sup Cheung 1 and Troben

More information

reports in applied measurement

reports in applied measurement reports in applied measurement ram reports in applied measurement A new transducer for directly measuring the forces and moments which a skier transfers to the skis F Z M Z A. Freddi, G. Olmi, D. Croccolo

More information

Fundamentals of Low Intensity Shock Calibration

Fundamentals of Low Intensity Shock Calibration Low intensity shock metrology for safety related applications Fundamentals of Low Intensity Shock Calibration Speaker : Yu-Chung Huang Date : 2014.08.20 Center for Measurement Standards/ Industrial Technology

More information

High Precision Mass Measurement in Automation Tatjana Ivanova 1, Jānis Rudzītis 2

High Precision Mass Measurement in Automation Tatjana Ivanova 1, Jānis Rudzītis 2 Solid State Phenomena Vol. 164 (2010) pp 19-24 Online available since 2010/Jun/30 at www.scientific.net (2010) Trans Tech Publications, Switzerland doi:10.4028/www.scientific.net/ssp.164.19 High Precision

More information

Glossary Innovative Measurement Solutions

Glossary Innovative Measurement Solutions Glossary GLOSSARY OF TERMS FOR TRANSDUCERS, LOAD CELLS AND WEIGH MODULES This purpose of this document is to provide a comprehensive, alphabetical list of terms and definitions commonly employed in the

More information

A Study on the Tube of Integral Propeller Shaft for the Rear-wheel Drive Automobile Using Carbon Composite Fiber

A Study on the Tube of Integral Propeller Shaft for the Rear-wheel Drive Automobile Using Carbon Composite Fiber A Study on the Tube of Integral Propeller Shaft for the Rear-wheel Drive Automobile Using Carbon Composite Fiber Kibong Han Mechatronics Department, Jungwon University, 85 Munmu-ro, Goesan-gun, South Korea.

More information

INVESTIGATION OF THE CALIBRATION CAPABILITIES OF A 1 KN M AND 10 KN M REFERENCE CALIBRATION MACHINE

INVESTIGATION OF THE CALIBRATION CAPABILITIES OF A 1 KN M AND 10 KN M REFERENCE CALIBRATION MACHINE IMEKO 23 rd TC3, 13 th TC5 and 4 th TC22 International Conference 30 May to 1 June, 2017, Helsinki, Finland INVESTIGATION OF THE CALIBRATION CAPABILITIES OF A 1 KN M AND 10 KN M REFERENCE CALIBRATION MACHINE

More information

Flowchart for the extraordinary calibrations prior to the redefinition of the kilogram. (BIPM proposal)

Flowchart for the extraordinary calibrations prior to the redefinition of the kilogram. (BIPM proposal) Flowchart for the extraordinary calibrations prior to the redefinition of the kilogram (BIPM proposal) Pauline Barat Michael Stock Alain Picard Richard Davis 1 CIPM informed of intention to use IPK Document

More information

Flexural properties of polymers

Flexural properties of polymers A2 _EN BUDAPEST UNIVERSITY OF TECHNOLOGY AND ECONOMICS FACULTY OF MECHANICAL ENGINEERING DEPARTMENT OF POLYMER ENGINEERING Flexural properties of polymers BENDING TEST OF CHECK THE VALIDITY OF NOTE ON

More information

Water Vapour Effects in Mass Measurement

Water Vapour Effects in Mass Measurement Water Vapour Effects in Mass Measurement N.-E. Khélifa To cite this version: N.-E. Khélifa. Water Vapour Effects in Mass Measurement. Measurement. Water Vapour Effects in Mass Measurement, May 2007, Smolenice,

More information

Force Key Comparison APMP.M.F-K2.a and APMP.M.F-K2.b (50 kn and 100 kn) Final Report 6 August Pilot: KRISS, Republic of Korea Yon-Kyu Park

Force Key Comparison APMP.M.F-K2.a and APMP.M.F-K2.b (50 kn and 100 kn) Final Report 6 August Pilot: KRISS, Republic of Korea Yon-Kyu Park Force Key Comparison APMP.M.F-K2.a and APMP.M.F-K2.b (50 kn and 100 kn) Final Report 6 August 2018 Pilot: KRISS, Republic of Korea Yon-Kyu Park Muktar Sawi (NMIM) Seif M. Osman (NIS) S.S.K.Titus (NPLI)

More information

SPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Force Proving Instruments

SPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Force Proving Instruments NABL 122-06 NATIONAL ACCREDITATION BOARD FOR TESTING AND CALIBRATION LABORATORIES SPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Force Proving Instruments Reviewed by MASTER

More information

TC-Chair Annual Report 2008/2009 TC-M

TC-Chair Annual Report 2008/2009 TC-M TC-Chair Annual Report 2008/2009 TC-M 20 May 2009 1. General Aspects The Contact Persons meeting was held in Malta at the beginning of March and was again very successful with over 70 participants form

More information

Final Report on the Torque Key Comparison CCM.T-K2 Measurand Torque: 0 kn m, 10 kn m, 20 kn m Dirk Röske 1), Koji Ogushi 2)

Final Report on the Torque Key Comparison CCM.T-K2 Measurand Torque: 0 kn m, 10 kn m, 20 kn m Dirk Röske 1), Koji Ogushi 2) Final Report on the Torque Key Comparison CCM.T-K Measurand Torque: kn m, 1 kn m, kn m Dirk Röske 1), Koji Ogushi ) 1) ) Dirk RÖSKE Physikalisch-Technische Bundesanstalt Department 1. Solid Mechanics orking

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 MTS FIELD SERVICE 14000 Technology Drive Eden Prairie, MN 55344 Hugh Casper Phone: 518 852 3977 CALIBRATION Valid To: September 30,

More information

50kNm TORQUE STANDARD MACHINE

50kNm TORQUE STANDARD MACHINE 50kNm TORQUE STANDARD MACHINE Shang Wei Lu, Li Tao, Cheng Yong Pei, Wang Yan, Qian Zhao Jun Shanghai Marine Equipment Research Institute, Shanghai, China ABSTRACT The paper introduces the working principle

More information

Final report Comparison Identifier: APMP.SIM.M.P-K1c Other designation: NIST-NPLI/Pressure/2

Final report Comparison Identifier: APMP.SIM.M.P-K1c Other designation: NIST-NPLI/Pressure/2 Final report Comparison Identifier: APMP.SIM.M.P-K1c Other designation: NIST-NPLI/Pressure/2 Bilateral comparison between NIST (USA) and NPLI (India) in the pneumatic pressure region 0.4 MPa to 4.0 MPa

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:. Av. Rio Consulado # 2614, Col. San Juan de Aragón

More information

THE UNCERTAINTY OF MEASUREMENT IN CALIBRATION USING A COMPARISON FORCE STANDARD MACHINE

THE UNCERTAINTY OF MEASUREMENT IN CALIBRATION USING A COMPARISON FORCE STANDARD MACHINE THE UNCERTAINTY OF MEASUREMENT IN CALIBRATION USING A COMPARISON FORCE STANDARD MACHINE Adrian Gherasimov 1, Eugen Ghita 1 Romanian Bureau of Legal Metrology, Force Laboratory Timisoara, Romania POLITEHICA

More information

DEVELOPMENT OF ANGULAR VELOCITY CALIBRATION FACILITY USING SELF-CALIBRATABLE ROTARY ENCODER

DEVELOPMENT OF ANGULAR VELOCITY CALIBRATION FACILITY USING SELF-CALIBRATABLE ROTARY ENCODER IMEKO 22 nd TC3, 12 th TC5 and 3 rd TC22 International Conferences 3 to 5 February, 2014, Cape Town, Republic of South Africa DEVELOPMENT OF ANGULAR VELOCITY CALIBRATION FACILITY USING SELF-CALIBRATABLE

More information

Characterization of Force Transducers for Dynamic Measurements

Characterization of Force Transducers for Dynamic Measurements Characterization of Force Transducers for Dynamic Measurements Michael Kobusch * 1 Introduction The measurement of time-dependent forces has gained particular importance over the past years. In this context,

More information

ISO 376 Calibration Uncertainty C. Ferrero

ISO 376 Calibration Uncertainty C. Ferrero ISO 376 Calibration Uncertainty C. Ferrero For instruments classified for interpolation, the calibration uncertainty is the uncertainty associated with using the interpolation equation to calculate a single

More information

THE S-S CURVE APPROXIMATION FOR GFRP TENSILE SPECIMEN BY USING INVERSE METHOD AND OPTIMIZATION

THE S-S CURVE APPROXIMATION FOR GFRP TENSILE SPECIMEN BY USING INVERSE METHOD AND OPTIMIZATION THE S-S CURVE APPROXIMATION FOR GFRP TENSILE SPECIMEN BY USING INVERSE METHOD AND OPTIMIZATION D. S. Shin and E. S. Jeon Department of Mechanical Engineering, Kongju National University, Korea E-Mail:

More information

Force Sensors. What is a force sensor?

Force Sensors. What is a force sensor? orce Sensors What is a force sensor? In physics, the definition of force is any agent that causes a mass to move. When you push an object, say a toy wagon, you re applying a force to make the wagon roll.

More information

Upgrade of 5m-Bench System for Traceable Measurements of Tapes and Rules at SASO-NMCC Dimensional Laboratory

Upgrade of 5m-Bench System for Traceable Measurements of Tapes and Rules at SASO-NMCC Dimensional Laboratory Upgrade of 5m-Bench System for Traceable Measurements of Tapes and Rules at SASO-NMCC Dimensional Laboratory Bülent ÖZGÜR 1,*, Okhan GANİOĞLU 1, Nasser Al-Qahtani 2, Faisal Al-Qahtani 2 1 TÜBİTAK, National

More information

Special edition paper

Special edition paper Development of New Aseismatic Structure Using Escalators Kazunori Sasaki* Atsushi Hayashi* Hajime Yoshida** Toru Masuda* Aseismatic reinforcement work is often carried out in parallel with improvement

More information

LOAD CELL DESIGN USING FIBER BRAGG GRATING SENSORS

LOAD CELL DESIGN USING FIBER BRAGG GRATING SENSORS Advanced Materials Development and Performance (AMDP2011) International Journal of Modern Physics: Conference Series Vol. 6 (2012) 203-208 World Scientific Publishing Company DOI: 10.1142/S2010194512003182

More information

Reliable Test Results

Reliable Test Results Intelligent testing Johannes J.Bührle - Agenda Reliable test results are a fundamental and highly topical aspect of materials testing. Using suitable examples we would like to show you how we view this

More information

SEISMIC RESPONSE EVALUATION OF AN RC BEARING WALL BY DISPLACEMENT-BASED APPROACH

SEISMIC RESPONSE EVALUATION OF AN RC BEARING WALL BY DISPLACEMENT-BASED APPROACH 3 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August -, 4 Paper No. 49 SEISMIC RESPONSE EVALUATION OF AN RC BEARING WALL BY DISPLACEMENT-BASED APPROACH Chang-Hun HYUN, Sanghyun

More information

Fatigue failure mechanisms of thin-walled hybrid plate girders

Fatigue failure mechanisms of thin-walled hybrid plate girders Fatigue failure mechanisms of thin-walled hybrid plate girders Pavol Juhás1,* 1Institute of Technology and Business in České Budějovice, Department of Civil Engineering, Okružní 517/10, 37001 České Budějovice,

More information

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad -500 043 MECHANICAL ENGINEERING TUTORIAL QUESTION BANK Name : INSTRUMENTATION AND CONTROL SYSTEMS Code : A70343 Class : IV B. Tech

More information

OIML D 28 DOCUMENT. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Conventional value of the result of weighing in air

OIML D 28 DOCUMENT. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Conventional value of the result of weighing in air INTERNATIONAL DOCUMENT OIML D 28 Edition 2004 (E) Conventional value of the result of weighing in air Valeur conventionnelle du résultat des pesées dans l'air OIML D 28 Edition 2004 (E) ORGANISATION INTERNATIONALE

More information

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B Force Load Washers for Forces of 7,5... 1 200 kn Type 9001A... 9071A 9081B, 9091B 1-component force sensor for measuring dynamic and quasistatic forces in z direction. F z Calibrated measuring range 100

More information

five Mechanics of Materials 1 ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture

five Mechanics of Materials 1 ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture five mechanics www.carttalk.com of materials Mechanics of Materials 1 Mechanics of Materials MECHANICS MATERIALS

More information

Supplementary comparison SIM.M.FF-S12. Final Report for Volume of Liquids at 20 L

Supplementary comparison SIM.M.FF-S12. Final Report for Volume of Liquids at 20 L Supplementary comparison SIM.M.FF-S12 Final Report for Volume of Liquids at 20 L Pilot: M. Maldonado (CENAM, Mexico) mmaldona@cenam.mx km 4.5 Carretera a los Cués, El Marqués, Qro 76241, Mexico Participants:

More information

Set No. 1 1. (a) Differentiate among Desired, Modifying and Interfering inputs. (b) How do you eliminate the effects of interfering and modifying inputs? Explain 2. (a) Define the term Transducer and explain

More information

DESIGN AND SIMULATION OF UNDER WATER ACOUSTIC MEMS SENSOR

DESIGN AND SIMULATION OF UNDER WATER ACOUSTIC MEMS SENSOR DESIGN AND SIMULATION OF UNDER WATER ACOUSTIC MEMS SENSOR Smitha G Prabhu 1, Nagabhushana S *2 1 Dept. Of Electronics and communication, Center for Nano Materials and MEMS, 2 Dept. of Electronics and Communication,

More information

Fuzzy logic based control design for active dancer closed loop web tension control

Fuzzy logic based control design for active dancer closed loop web tension control Fuzzy logic based control design for active dancer closed loop web tension control GANESHTHANGARAJ PONNIAH*, MUHAMMAD ZUBAIR * YANG- HOI DOH** and KYUNG-HYUN CHOI* *Department of Mechatronics engineering,

More information

ASSOCIATE DEGREE IN ENGINEERING EXAMINATIONS. SEMESTER 2 May 2013

ASSOCIATE DEGREE IN ENGINEERING EXAMINATIONS. SEMESTER 2 May 2013 ASSOCIATE DEGREE IN ENGINEERING EXAMINATIONS SEMESTER 2 May 2013 COURSE NAME: CODE: Mechanical Engineering Science [8 CHARACTER COURSE CODE] GROUP: AD-ENG 1 DATE: TIME: DURATION: "[EXAM DATE]" "[TIME OF

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information