20th IMEKO TC3 International Conference on Measurement of Force, Mass and Torque 2007
|
|
- Austen Fowler
- 6 years ago
- Views:
Transcription
1 20th IMEKO TC3 International Conference on Measurement of Force, Mass and Torque 2007 Merida, Mexico 27 November-1 December 2007 ISBN:
2 Printed from e-media with permission by: Curran Associates, Inc. 57 Morehouse Lane Red Hook, NY Some format issues inherent in the e-media version may also appear in this print version. Copyright (2007) by IMEKO All rights reserved. Printed by Curran Associates, Inc. (2009) For permission requests, please contact IMEKO at the address below. IMEKO Secretariat P.O. Box 457 H-1371 Budapest Hungary Phone/Fax: imeko@t-online.hu Additional copies of this publication are available from: Curran Associates, Inc. 57 Morehouse Lane Red Hook, NY USA Phone: Fax: curran@proceedings.com Web:
3 TABLE OF CONTENTS Qualification of Force Standard Machines... 1 Jorge M. E. Saffar, C. A. Koch, Eunice M. Ferreira Marques, Renata W. Rocha, R. S. Oliveira, Ademir R. Chagas, Rodrigo F. Guilherme A New Type of Force Sensor A. Stoian, T. Kuberczyk, G. Schultes Strain Sensors Based on Bragg Gratings K. Haase Investigations of Load Cells Made of Single-crystalline Silicon with Sputrered-on Strain Gauges S. Mäuselein, O. Mack, R. Schwartz, G. Jäger A New Weigh-in-motion and Traffic Monitoring System P. Barsanescu, P. Carlescu, D. Mihai Stefanescu A New Six-component Force Vector Sensor First Investigations S. Lietz, F. Tegtmeier, R. Kumme, D. Röske, U. Kolwinski, K. Zöller Comparison of Shock and Sine Force Calibration Methods M. Kobusch, A. Link, A. Buss, T. Bruns Suggestions on How to Include the Effect of Reproducibility in the Evaluation of Simplified Calibration Procedures G. Wegener, H. W. Werner The Relevance of Using a Monte Carlo Method to Evaluate Uncertainty in Mass Calibration J. A. Sousa, A. S. Rineiro, A. B. Forbes, P. M. Harris, F. Carvalho, L. Bacelar Analysis of Change of Mass Difference Between Weight Support Plates During Subdivision of 1 Kg Matej Grum, Martin Terlep Design and Performance of the New Sartorius Robot-system T. Fehling, T. Fröhlich, D. Heydenbluth Fully Automatic Mass Laboratory from 1 Mg Up to 50 Kg Robots Perform High Precision Mass Determination Christian Buchner Mass Dissemination Using a Fully Automated Mass Comparator Robot System T. Fröhlich, T. Fehling, B. Gatzemeier, S. Osang, D. Heydenbluth Evaluation of Standard Uncertainty of Measured Mass Difference on 10 Kg Comparator Balance Gasper Vindisar, Matej Grum, Martin Terlep Automated Volume Measurement for Weights Using Acoustic Volumeter M. Ueki, T. Kobata, K. Ueda, A. Ooiwa Load Cells Temperature Effect in Force Applications for Automotive Industry Requirements David González Espinosa, Edgar Pérez Ramírez Enlargement of the Force Capability at CEM: Development of a 10 MN Hydraulic Force Standard Machine J. A. Robles Carbonell, J. A. Fernández García, Jorge L. Robles Verdecia The Use of Strain Gauges in the Kenyan Industry for Measurement David Kimetto Implementation of the Reference Force Standard in the Croatian Metrology and Interlaboratory Comparison Mladen Franz, Željko Alar, Tamara Aleksandrov Amorphous Wire Based Stress Sensor Working with Low Carrier Frequency Marinel Temneanu, Romeo Ciobanu, Codrin Donciu Strain Gauged Elastic Elements for Force and Related Quantities Measurement Dan Mihai Stefanescu Characterization of Quantum-weight Generating Cantilever Device Jae-Hyuk Choi, Kwang-Cheol Lee, Yun-Won Kim, Min-Seok Kim Development of Mass and Length Measurement System on Conveyor Belt (2nd Report) Takanori Yamazaki, Akihiro Watanabe, Hideo Ohnishi, Masaaki Kobayashi, Shigeru Kurosu Determination of Mass Differences in the Range of Units of g by Radioactivity Measurement Richard Tykva The Repeatability Optimization of an Automated Weighing Comparator S. Lee, J. W. Chung, W. G. Lee, K. P. Kim
4 Metrology in Developing Economies Jamaican Experience in Publishing Mass CMCs in Appendix C of MRA of CIPM M. Sanz, L. O. Becerra Mass Determination of 1 Kg Silicon Spheres for Avogadro Project H. Fang, A. Picard Magnetic Levitation System for the Dissemination of a Non-artifact Based Kilogram Zeina Jabbour, Patrick Abbott, Edwin Williams, Ruimin Liu, Vincent Lee A Comparison of Primary Platinum-iridium Kilogram Mass Standards Among Eighteen European NMIs S. Davidson Realization of Forces (2N-20N) by Primary Method Kamlesh K. Jain, S. S. K. Titus, H. N. P. Poddar, S. K. Dhulkhed Add-on of the 2-MN Force Standard Machine for Testing Load Cells Oliver Mack The Long-term Behaviour of Force Transducers As a Criteria for the Selection of New Transfer Standards Aimo Pusa Performance of Force Comparator with Reference to Tuning-fork Type Force Transducer Toshiyuki Hayashi, Yoshihisa Katase, K. Ueda, Tsyoshi Hoshino, Hiroshi Suzawa, Masaaki Kobayashi Continuous Calibration of Force Transducers Laurence Brice, A. Knott, Alan Wilson Statistical Analysis of 2 MN and 4 MN Force Range Key Comparisons T. Bartel Dissemination of the Force Unit in Italy: Intercomparison Results Up to 20 kn C. Ferrero The SIT Activity to Disseminate Physical Quantities in Italy: Calibration of Material Testing Machine Intercomparisons C. Ferrero, Luciano Bianchi Determination of Air Density with Buoyancy Artefacts Sari Semenoja, Kari Riski, Leena Stenlund Temperature Control in the k Range for Density Measurements Horst Bettin Solids Volume by Hydrostatic Weighing Comparison Between CENAM-Mexico and INMETRO- Brazil. Sim.7.34-B L. O. Becerra, Dalni Malta, Luz. Ma. Centeno, José Julio Pinheiro Design of an Automatic Apparatus for the Calibration of On-line Densimeters S. Lorefice, A. Malengo, M. Caravaggio, L. Cianciotta Automatic Testing Facility for Determining Liquids and Solids Density and Determining the Volume of E1 Weights Christian Buchner A New Image Processing System for Hydrometer Calibration Developed at CENAM Luis M. Peña, J. Carlos Pedraza, L. O. Becerra, Carlos A. Galván Linking SIM Mass Comparisons to the KCRV on 1 Kg L. O. Becerra Static and Dynamic Evaluation of the CENAM (Mexico) 150 kn Primary Force Standard Machine by Means of the INRiM (Italy) 100 kn Six-component Dynamometer C. Marinari, F. Mazzoleni, J. C. Torres-Guzman, D. Ramírez-Ahedo Instrumentation Improvements in the MMS-150 kn Force Standard Machine, CENAM Mexico C. Morales-Aguillon, J. C. Torres-Guzman, D. Ramírez-Ahedo Comparison between the CENAM (Mexico) 150 kn and the INRiM (Italy) 1 MN Force Standard Machines C. Marinari, J. C. Torres-Guzman, A. Germak, D. Ramírez-Ahedo Force Standards Comparison at 1 kn and 50 kn Among National Laboratories from EUROMET and SIM C. Villarroel-Poblete, J. C. Torres-Guzman, P. Averlant, A. Knott, R. Kumme, J. A. Robles-Carbonell, D. Ramírez- Ahedo, L. R. Giobergia Measuring the Free-fall Acceleration with the IMGC-02 Transportable Absolute Gravimeter G. D'Agostino, A. Germak, C. Origlia, D. Quagliotti, G. Barbato The Intercomparison of Charpy Impact Pendulum Calibration C. Ferrero Metrology Impact in Technological Universities, Mexico S. Martínez-Sanchez, F. M. C. Laguna-Aguilar, J. C. Torres-Guzman
5 Hybrid Torque Standard Machine for 1kN M Developed in CENAM D. Ramírez-Ahedo, J. C. Torres-Guzman, F. Martinez-Juarez Torque Proficiency Test Among Accredited Laboratories in Mexico J. Galvan-Mancilla, J. C. Torres-Guzman, D. Ramírez-Ahedo The Torque Metrology Management in Brazil L. C. Cabral de Freitas, S. R. Reis da Costa, R. S. Oliveira, C. A. Koch Development of the New LNE 50 N m Deadweight Torque Standard Machine P. Averlant, A. Gosset Mathematical Representation of Reference Torque Transducers in Partial-range Regimes A. Brüge Expansion of the Calibration Range and Improvement of the Uncertainty in the 1 kn m Deadweight Torque Standard Machine K. Ohgushi, A. Nishino, T. Ota, K. Ueda Advantage of Carrier Frequency in Contactless High Precision Torque Measurement Systems S. Kuhn Establishment of Torque Standards in KRISS of Korea P. Yon-Kyu, K. Min-Seok, K. Jong-Ho, C. Jae-Hyuk, K. Dae-Im Analysis of Change of Mass Difference Between Weight Support Plates During Subdivision of 1 Kg Matej Grum, Martin Terlep Measurement of Gravitational Acceleration Values at the Calibration Laboratories in Korea S. Y. Woo, I. M. Choi, H. W. Song Activities Designed to Establish Relationships Between Concepts As a Didactic Strategy in the Metrology Teaching Process I. Praxedis, M. Santamaría, C. Román Tejeda Traceability Concept Teaching by Means of Experimental Procedures for Chemistry Undergraduate Students at UNAM R. Tejeda, F. Rivera, I. Santamaría, P. Reyes S. y Ortega The Achievable Uncertainty for Balance-based Force Standard Machines in the Range from Micronewton to Newton Jens Illemann Progress on the BIPM Watt Balance A. Picard, H. Fang, M. Stock The New Version of the German Torque Calibration Standard DIN 51309: a Comparative Overview D. Röske Recent Advances on the Redefinition of the Kilogram Richard Davis Aims, Objectives, Structure and Activity of IMEKO the Instrumentation and Measurement Confederation Antonio Cruz Serra, Leo Van Biesen Author Index
Comparison between the CENAM (Mexico) 150 kn and the INRiM (Italy) 1 MN force standard machines
IMEKO 20 th TC3, 3 rd TC16 and 1 st TC22 International Conference Cultivating metrological knowledge 27 th to 30 th November, 2007. Merida, Mexico. Comparison between the CENAM (Mexico) 150 kn and the
More informationXIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal
XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 9, Lisbon, Portugal IMPROVEMENT OF METROLOGICAL CHARACTERISTICS OF INTI S 11 kn FORCE STANDARD MACHINE BY USING THE CENAM S SIX-COMPONENT
More information18th IMEKO TC3 Conference on Force, Mass and Torque 2002
18th IMEKO TC3 Conference on Force, Mass and Torque 2002 Joint International Conference on Force, Mass, Torque, Hardness and Civil Engineering Metrology in the Age of Globalization Celle, Germany 24 26
More informationEVALUATION OF STATIC AND DYNAMIC PARASSITIC COMPONENTS ON THE INRIM 1 MN PRIMARY FORCE STANDARD MACHINE BY MEANS THE 500 kn SIX-COMPONENT DYNAMOMETER
XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal EVALUATION OF STATIC AND DYNAMIC PARASSITIC COMPONENTS ON THE INRIM 1 MN PRIMARY FORCE STANDARD MACHINE
More informationIMKO TC3/APMF '98. Proceedings of. Taejon, Republic. Organized by Korea Research Institute of Standards and Science (KRISS)
IMKO TC3/APMF '98 Proceedings of the 16th International Conference on Force, Mass and Torque Measurements in Parallel with Asia-Pacific Symposium on Measurement of Mass and Force 14-18 September 1998 Taejon,
More informationFORCE NATIONAL STANDARDS COMPARISON BETWEEN CENAM/MEXICO AND NIM/CHINA
FORCE NATIONAL STANDARDS COMPARISON BETWEEN CENAM/MEXICO AND NIM/CHINA Qingzhong Li *, Jorge C. Torres G.**, Daniel A. Ramírez A.** *National Institute of Metrology (NIM) Beijing, 100013, China Tel/fax:
More informationEvaluation of Force Standard Machines by using Build-up System
Evaluation of Force Standard Machines by using Build-up System TC3 Round Table Nov. 24, 2010 Y.-K. Park and D.-I. Kang Contents Introduction Basic theory Application examples Dynamic behavior of deadweight
More informationSeptember 17-21, 2001, Istanbul / TURKEY
INTERNATIONAL MEASUREMENT CONFEDERATION Technical Committee TC3 on Measurement of Force, Mass and Torque Proceedings of the 17 International Conference FORCE, MASS, TORQUE AND PRESSURE MEASUREMENTS AT
More informationSIM FORCE STANDARDS COMPARISON UP TO 10 kn
SIM FORCE STANDARDS COMPARISON UP TO 10 kn Jorge C. Torres-Guzmán, Daniel A. Ramírez-Ahedo Centro Nacional de Metrología, CENAM.. ABSTRACT A comparison in the quantity of force was carried out among the
More informationFinal Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR
Final Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR Jin Wan Chung 1, Shih Mean Lee, Sungjun Lee 1 1 Korea Research Institute of Standards
More informationTC-Chair Annual Report 2008/2009 TC-M
TC-Chair Annual Report 2008/2009 TC-M 20 May 2009 1. General Aspects The Contact Persons meeting was held in Malta at the beginning of March and was again very successful with over 70 participants form
More informationEUROMET Project 702 EUROMET.M.D-K4
EUROMET TC-M Meeting 2007 Thursday, 01 March 2007 EUROMET Project 702 EUROMET.M.D-K4 Comparison of the calibrations of high resolution hydrometers for liquid density determinations Salvatore Lorefice INRIM,
More informationEVALUATION OF ADSORPTION EFFECT BY USING SILICON SPHERE AND SILICON SURFACE ARTEFACTS
XVIII IMEKO WORLD CONGRESS Metrology for a Sustainable Development September, 17 22, 2006, Rio de Janeiro, Brazil EVALUATION OF ADSORPTION EFFECT BY USING SILICON SPHERE AND SILICON SURFACE ARTEFACTS Jin
More informationMulti-Capacity Load Cell Concept
Sensors & Transducers 4 by IFSA Publishing, S. L. http://www.sensorsportal.com Multi-Capacity Load Cell Concept Seif. M. OSMAN, Ebtisam H. HASAN, H. M. EL-HAKEEM, R. M. RASHAD, F. KOUTA National Institute
More informationCCM short note on the dissemination process after the proposed redefinition of the kilogram
CCM short note on the dissemination process after the proposed redefinition of the kilogram Consultative Committee for Mass and Related Quantities 1. Introduction This note proposes how the mise en pratique
More informationMass determination of 1 kg silicon spheres for Avogadro project
IMEKO 20 th TC3, 3 rd TC16 and 1 st TC22 International Conference Cultivating metrological knowledge 27 th to 30 th November, 2007. Merida, Mexico. Mass determination of 1 kg silicon spheres for Avogadro
More informationAir Density Determination Using 1 kg Buoyancy Mass Comparison(III)
Air Density Determination Using 1 kg Buoyancy Mass Comparison(III) Jin-Wan CHUNG, Kyung-Ho CHANG, Woo-Gab LEE, Kwang-Pyo KIM Division of Physical Metrology, Korea Research Institute of Standards and Science(KRISS)
More informationModelling of a dynamic torque calibration device and determination of model parameters
ACTA IMEKO June 2014, Volume 3, Number 2, 14 18 www.imeko.org Modelling of a dynamic torque calibration device and determination of model parameters Leonard Klaus, Thomas Bruns, Michael Kobusch Physikalisch-Technische
More informationNational Physical Laboratory Hampton Road Teddington Middlesex United Kingdom TW11 0LW
NPL REPORT ENG 17 Report on EURAMET key comparison of multiples and submultiples of the kilogram (EURAMET.M.M-K2.1) M Perkin NOT RESTRICTED July 2009 National Physical Laboratory Hampton Road Teddington
More informationAutomated volume measurement for weihts using acoustic volumeter
IMEKO 20th TC3, 3rd TC16 and 1st TC22 International Conference Cultivating metrological knowledge 27th to 30th November, 2007. Merida, Mexico. Automated volume measurement for weihts using acoustic volumeter
More informationA comparison of primary platinum-iridium kilogram mass standards among eighteen European NMIs
IMEKO 20 th TC3, 3 rd TC16 and 1 st TC22 International Conference Cultivating metrological knowledge 27 th to 30 th November, 2007. Merida, Mexico. A comparison of primary platinum-iridium kilogram mass
More informationTHE NEW 1.1 MN m TORQUE STANDARD MACHINE OF THE PTB BRAUNSCHWEIG/GERMANY
THE NEW 1.1 MN m TORQUE STANDARD MACHINE OF THE PTB BRAUNSCHWEIG/GERMANY D. Peschel 1, D. Mauersberger 1, D. Schwind 2, U. Kolwinski 2 1 Solid mechanics department, PTB, Germany 2 Gassmann Theiss Messtechnik
More informationPTB S 16.5 MN HYDRAULIC AMPLIFICATION MACHINE AFTER MODERNIZATION
IMEKO 22 nd TC3, 15 th TC5 and 3 rd TC22 International Conferences 3 to 5 February, 2014, Cape Town, Republic of South Africa PTB S 16.5 MN HYDRAULIC AMPLIFICATION MACHINE AFTER MODERNIZATION R. Kumme
More information2nd Multiflow Summer School on Turbulence 2015
2nd Multiflow Summer School on Turbulence 2015 Journal of Physics: Conference Series Volume 708 Madrid, Spain 25 May 26 June 2015 Editor: Javier Jimenez ISBN: 978-1-5108-2327-3 ISSN: 1742-6588 Printed
More informationMaintaining and disseminating the kilogram following its redefinition
Metrologia PAPER OPEN ACCESS Maintaining and disseminating the kilogram following its redefinition To cite this article: 2017 Metrologia 54 S99 View the article online for updates and enhancements. Related
More informationMODEL-BASED ANALYSIS OF THE DYNAMIC BEHAVIOUR OF A 250 KN SHOCK FORCE CALIBRATION DEVICE
XX IMEKO World Congress Metrology for Green Growth September 9 14, 212, Busan, Republic of Korea MODEL-BASED ANALYSIS OF THE DYNAMIC BEHAVIOUR OF A 25 KN SHOCK FORCE CALIBRATION DEVICE Michael Kobusch,
More informationCertification of a High Capacity Force Machine for Testing of Load Cells According to OIML R60
Certification of a High Capacity Force Machine for Testing of Load Cells According to OIML R60 Bernd Meißner Physikalisch-Technische Bundesanstalt Weighing Instruments Laboratory Braunschweig Abstract
More informationSupplementary comparison SIM.M.FF-S12. Final Report for Volume of Liquids at 20 L
Supplementary comparison SIM.M.FF-S12 Final Report for Volume of Liquids at 20 L Pilot: M. Maldonado (CENAM, Mexico) mmaldona@cenam.mx km 4.5 Carretera a los Cués, El Marqués, Qro 76241, Mexico Participants:
More informationForce Key Comparison CCM.F-K1.a and CCM.F-K1.b 5 kn and 10 kn. Aimo Pusa MIKES Finland
Force Key Comparison CCM.F-K1.a and CCM.F-K1.b 5 kn and 10 kn Aimo Pusa 09.02.2009 MIKES Finland 2 Content Page Content 3 Foreword 4 Chapter 1 1.1 General 6 1.2 Characteristics of the transducers 8 1.3
More informationMASS DETERMINATION OF SILICON SPHERES USED FOR THE AVOGADRO PROJECT
MASS DETERMINATION OF SILICON SPHERES USED FOR THE AVOGADRO PROJECT Michael Borys, Michael Gläser, Michael Mecke Physikalisch-Technische Bundesanstalt (PTB), Germany ABSTRACT Spheres made of a silicon
More informationCOMPLETION AND MEASUREMENT UNCERTAINTY BUDGET OF THE MULTI-COMPONENT MEASURING DEVISE FOR FORCE UP TO 1 MN AND TORQUE UP TO 2 KN M
XXI IMEKO World Congress Measurement in Research and Industry August 30 September 4, 2015, Prague, Czech Republic COMPLETION AND MEASUREMENT UNCERTAINTY BUDGET OF THE MULTI-COMPONENT MEASURING DEVISE FOR
More informationSTUDY OF THE BEST MEASUREMENT CAPABILITY IN ROCKWELL SCALE AT THE BRAZILIAN NMI INMETRO S PRIMARY HARDNESS STANDARD MACHINE
XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal STUDY OF THE BEST MEASUREMENT CAPABILITY IN ROCKWELL SCALE AT THE BRAZILIAN NMI INMETRO S PRIMARY HARDNESS
More informationOn the redefinition of the kilogram. Dr Philippe RICHARD
On the redefinition of the kilogram Dr Philippe RICHARD Agenda 1. Recent history of IPK and new SI 2. The CCM conditions 3. The joint CCM and CCU roadmap 4. The mise en pratique of the definition of the
More informationFlowchart for the extraordinary calibrations prior to the redefinition of the kilogram. (BIPM proposal)
Flowchart for the extraordinary calibrations prior to the redefinition of the kilogram (BIPM proposal) Pauline Barat Michael Stock Alain Picard Richard Davis 1 CIPM informed of intention to use IPK Document
More informationCharacterization of Force Transducers for Dynamic Measurements
Characterization of Force Transducers for Dynamic Measurements Michael Kobusch * 1 Introduction The measurement of time-dependent forces has gained particular importance over the past years. In this context,
More informationFEEDBACK CONTROLLED DEADWEIGHT MACHINE
FEEDBACK CONTROLLED DEADWEIGHT MACHINE G. Barbato 1, S. Desogus 2, A. Germak 2 and M. Vattasso 3 1 DSPEA, Politecnico di Torino, C.so Duca degli Abruzzi 24, 10129 Torino, Italy 2 Istituto di Metrologia
More informationMechanics and Acoustics
info sheet PHYSIKALISCH-TECHNISCHE BUNDESANSTALT DIVISION 1 Mechanics and Acoustics Mechanics and Acoustics How heavy, how strong, how fast, how loud? Division 1 is your reference for the precision measurement
More informationContinuous Mass Measurement in Checkweighers and Conveyor Belt Scales
Continuous Mass Measurement in Checkweighers and Conveyor Belt Scales Takanori YAMAZAKI*, Yoshiharu SAKURAI**, Hideo OHNISHI*** Masaaki KOBAYASHI***, Shigeru KUROSU** *Tokyo Metropolitan College of Technology,
More informationUNCERTAINTY IN TORQUE CALIBRATION USING VERTICAL TORQUE AXIS ARRANGEMENT AND SYMMETRICAL TWO FORCE MEASUREMENT
UNCERTAINTY IN TORQUE CALIBRATION USING VERTICAL TORQUE AXIS ARRANGEMENT AND SYMMETRICAL TWO FORCE MEASUREMENT Dieter Kenzler 1, Jörg Oblasser 2, Andreas Subaric-Leitis 2 and Christian Ullner 2 1 ) SCHATZ
More informationSIM SIM.M.D-K3. provide. SIM.M.M-K5 for. A set of. Institute LACOMET LATU INTI. Country Costa Rica Uruguay Argentina Chile México Canada Brazil
FINAL REPORT SIM COMPARISON IN VOLUME OF WEIGHTS SIM.M.D-K3 Kornblit, F 1 ; Leiblich, J. 1 ; Becerra, L.O. ; Peña, L.M. ; Luján, L. ; Díaz,J.C. ; Centeno, L.M. ; Ramos, O 3 ; Rodríguez, S. 3 ; Santo, C.
More informationMASS AND VOLUME COMPARISONS AT MIKES
MITTATEKNIIKAN KESKUS CENTRE FOR METROLOGY AND ACCREDITATION Julkaisu J4/2000 MASS AND VOLUME COMPARISONS AT MIKES Additional results to the EA intercomparison of weights 1 mg 100 g (Ma1) and to the EUROMET
More informationReport on CCM Pilot Study CCM.R-kg-P1. Comparison of future realizations of the kilogram. Final Report
Report on CCM Pilot Study CCM.R-kg-P1 Comparison of future realizations of the kilogram Final Report 27 June 2017 M. Stock 1, P. Barat 1, F. Beaudoux 2, P. Espel 2, P. Pinot 2, F. Piquemal 2, M. Thomas
More informationInvestigation of Piezoelectric Force Measuring Devices in Force Calibration and Force. Standard Machines
Proceedings of the 17 th International Conference on Force, Mass, Torque and Pressure Measurements, Investigation of Piezoelectric Force Measuring Devices in Force Calibration and Force Standard Machines
More informationAnalysis of shock force measurements for the model based dynamic calibration
8 th Worshop on Analysis of Dynamic Measurements May 5-6, 4 Turin Analysis of shoc force measurements for the model based dynamic calibration Michael Kobusch, Sascha Eichstädt, Leonard Klaus, and Thomas
More informationFinal Report on CIPM key comparison of multiples and submultiples of the kilogram (CCM.M-K2)
1 Final Report on CIPM key comparison of multiples and submultiples of the kilogram (CCM.M-K) 1. Introduction L.O. Becerra 1, W. Bich, N. Bignell 3, G.D. Chapman 4, J.W. Chung 5 S. Davidson 6, M. Gläser
More informationIMEKO 2014 TC3, TC5, TC 22 Program. Tues. 04-Feb-14. TC22 Dyn Meas TC3 TC3 TC3/P11 TC3/P27 ID: 107 ID: 126 TC3/P28 TC3/P12 ID: 14 ID: :30
Sun 02-Feb-14 IMEKO 2014 TC3, TC5, TC 22 Program Mon Tues Wed TC3/P11 ID: 107 TC3/P27 ID: 126 TC22/P7 ID: 86 TC3/P23 ID: 122 P7 ID: 115 09:00 09:20 Q/A Q/A Q/A Q/A Q/A Q/A TC3/P12 ID: 14 TC3/P28 ID: 134
More informationProposed change to the definition of the kilogram: Consequences for legal metrology
SI UNITS Proposed change to the definition of the kilogram: Consequences for legal metrology RICHARD DAVIS Consultant, International Bureau of Weights and Measures (BIPM) The General Conference on Weights
More informationEMRP JRP SIB-05. NewKILO. Developing a practical means of disseminating the redefined kilogram (June 2012 May 2015) Stuart Davidson, NPL, UK
EMRP JRP SIB-05 NewKILO Developing a practical means of disseminating the redefined kilogram (June 2012 May 2015) Stuart Davidson, NPL, UK CCM M-e-P Workshop BIPM, November 2012 Background This Project
More informationMEASUREMENT UNCERTAINTY OF ROTATING TORQUE TRANSDUCERS WHEN USED IN PARTIAL LOAD RANGES
XVIII IMEKO WORLD CONGRESS Metrology for a Sustainable Development September, 17, 006, Rio de Janeiro, Brazil MEASUREMENT UNCERTAINTY OF ROTATING TORQUE TRANSDUCERS WHEN USED IN PARTIAL LOAD RANGES Georg
More informationLINKING SIM MASS COMPARISONS TO THE KCRV ON 1 kg. Luis O. Becerra CENAM Querétaro, Qro., Mexico,
LINKING SIM MASS COMPARISONS TO THE KCRV ON 1 kg Luis O. Becerra CENAM Querétaro, Qro., Mexico, lbecerra@cenam.mx Abstract. Within the frame of SIM (Sistema Interamericano de Metrología), inter laboratory
More informationHigh pressure comparison among seven European national laboratories
IMEKO 20 th TC3, 3 rd TC16 and 1 st TC22 International Conference Cultivating metrological knowledge 27 th to 30 th November, 2007. Merida, Mexico. High pressure comparison among seven European national
More informationDESIGN, DEVELOPMENT, AND COMMISSIONING OF A 120 kn DEADWEIGHT FORCE STANDARD MACHINE
DESIGN, DEVELOPMENT, AND COMMISSIONING OF A 120 kn DEADWEIGHT FORCE STANDARD MACHINE Andy Knott National Physical Laboratory, United Kingdom ABSTRACT This paper describes the development of a 120 kn deadweight
More informationAsia-Pacific Symposium on Measurement of Mass, Force and Torque
Korea Research Institute of Standards and Science (KRISS) AsiaPacific Symposium on Measurement of Mass, Force and Torque APMF 2005 August 30September 3, 2005 Jeju, Korea Printed from emedia with permission
More informationMETHODS TO CONFIRM THE MEASUREMENT CAPABILITY OF THE FORCE STANDARD MACHINES AFTER REINSTALLATION
IMEKO 22 nd TC3, 12 th TC5 and 3 rd TC22 International Conferences 3 to 5 February, 2014, Cape Town, Republic of South Africa METHODS TO CONFIRM THE MEASUREMENT CAPABILITY OF THE FORCE STANDARD MACHINES
More informationReduction of the effect of floor vibrations in a checkweigher using an electromagnetic force balance system
ACTA IMEKO ISSN: 1 870X July 017, Volume 6 Number, 65 69 Reduction of the effect of floor vibrations in a checkweigher using an electromagnetic force balance system Yuji Yamakawa 1, Takanori Yamazaki 1
More informationMise en pratique for the definition of the kilogram in the SI
Mise en pratique for the definition of the kilogram in the SI Consultative Committee for Mass and Related Quantities 1. Introduction The purpose of this mise en pratique, prepared by the Consultative Committee
More informationAPPLICATION OF A SCANNING VIBROMETER FOR THE PERIODIC CALIBRATION OF FORCE TRANSDUCERS
XX IMEKO World Congress Metrology or Green Growth September 9 14, 01, Busan, Republic o Korea APPLICATION OF A SCANNING VIBROMETER FOR THE PERIODIC CALIBRATION OF FORCE TRANSDUCERS Christian Schlegel,
More informationINVESTIGATION OF TRANSFER STANDARDS IN THE HIGHEST RANGE UP TO 50 MN WITHIN EMRP PROJECT SIB 63 Falk Tegtmeier 1, Michael Wagner 2, Rolf Kumme 3
XXI IMEKO World Congress Measurement in Research and Industry August 30 September 4, 2015, Prague, Czech Republic INVESTIGATION OF TRANSFER STANDARDS IN THE HIGHEST RANGE UP TO 50 MN WITHIN EMRP PROJECT
More informationTHE NEW WATT BALANCE EXPERIMENT AT METAS
XX IMEKO World Congress Metrology for Green Growth September 9 14, 2012, Busan, Republic of Korea THE NEW WATT BALANCE EXPERIMENT AT METAS H. Baumann, A. Eichenberger, B. Jeckelmann, Ch. Beguin +, R. Clavel,
More informationPROTOCOL OF MASS AND VOLUME COMPARISONS BETWEEN SIM NMIs
PROTOCOL OF MASS AND VOLUME COMPARISONS BETWEEN SIM NMIs 1. General Information This comparison is being carried out in order to compare the degree of equivalence in mass, conventional mass, volume and
More informationMicro- and Nanoforce Metrology at PTB
1 IMEKO 2010, TC3, Small Force Workshop Micro- and Nanoforce Metrology at PTB Uwe Brand, Lutz Doering, Vladimir Nesterov and Febo Menelao PTB (Germany) 2 Overview 1. Mass balance based devices a) 400 mn
More informationKilogram: new definition, selected mises-en-pratique and direct link with SMD activities
Kilogram: new definition, selected mises-en-pratique and direct link with SMD activities Mieke Coenegrachts WMD 2018 Outline Mass at the SMD - ENS Definition of the kilogram Present New Practical realization
More informationConcept and setup of a multi-component facility for force and torque in the range of 1 MN and 2 kn m
CT IMEKO June 2014, Volume 3, Number 2, 39 43 www.imeko.org Concept and setup of a multi-component facility for force and torque in the range of 1 MN and 2 kn m Sebastian aumgarten, Dirk Röske, Holger
More informationInvestigations for the model based dynamic calibration of force transducers by using shock excitation
ACTA IMEKO ISSN: 2221 870X June 2015, Volume 4, Number 2, 45 51 Investigations for the model based dynamic calibration of force transducers by using shock excitation Michael Kobusch 1, Sascha Eichstädt
More information< Final report > Report on the APMP.M.F-S1 supplementary comparison for 2 MN Force
< Final report > Report on the APMP.M.F-S1 supplementary comparison for 2 MN Force Kazunaga Ueda*, Toshiyuki Hayashi*, Hiroshi Maejima*, Rolf Kumme**, Dirk Röske**, Mark Seidel** * National Metrology of
More informationIncreased Requirements for Higher Nominal Forces, Necessities and Possibilities to Measure Them
B 3.1 Increased Requirements for Higher Nominal Forces, Necessities and Possibilities to Measure Them Dr. Schäfer, André Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45, 64293 Darmstadt andre.schaefer@hbm.com
More informationA Collaboration Between Ten National Measurement Institutes To Measure The Mass Of Two One Kilogram Mass Standards
NPL REPORT CMAM 36(a) A Collaboration Between Ten National Measurement Institutes To Measure The Mass Of Two One Kilogram Mass Standards This Report Supersedes NPL Report CMAM 36 I Severn SEPTEMBER 2000
More informationBIPM/CIPM key comparison CCM.FF-K Final Report for Volume of Liquids at 20 L and 100 ml - Piloted by Centro Nacional de Metrología (CENAM)
BIPM/CIPM key comparison CCM.FF-K4.1.2011 Final Report for Volume of Liquids at 20 L and 100 ml - Piloted by Centro Nacional de Metrología (CENAM) Pilot: R. Arias, M. Maldonado (CENAM, Mexico) rarias@cenam.mx
More informationFundamentals of Mass Determination
Fundamentals of Mass Determination Michael Borys Roman Schwartz Arthur Reichmuth Roland Nater Fundamentals of Mass Determination 123 Michael Borys Fachlabor 1.41 Physikalisch-Technische Bundesanstalt Bundesallee
More informationANNEXE 8. Technical protocols for the interlaboratory comparisons
ANNEXE 8 Technical protocols for the interlaboratory comparisons TECHNICAL PROTOCOL FOR BILATERAL COMPARISON (Magnitude of the complex charge sensitivity of accelerometers) EURAMET.AUV.V-S1 1. INTRODUCTION
More informationCONTINUOUS WEIGHING ON A CONVEYOR BELT WITH FIR FILTER
CONTINUOUS WEIGHING ON A CONVEYOR BELT WITH FIR FILTER Ryosuke Tasaki 1, Takanori Yamazaki 2, Hideo Ohnishi 3, Masaaki Kobayashi 3, Shigeru Kurosu 4 1 Dept. of Mechanical Eng., Kyoto Institute of Technology,
More informationEuropean Association of National Metrology Institutes
European Association of National Metrology Institutes EURAMET GUIDELINES ON TEMPERATURE: Extrapolation of SPRT calibrations below the triple point of argon, 83.8058 K, and traceability in baths of liquid
More informationFORCE STANDARDS COMPARISON BETWEEN PTB (GERMANY) AND CENAM (MEXICO).
FORCE STANDARDS COMPARISON BETWEEN PTB (GERMANY) AND CENAM (MEXICO). Jorge C. Torres-Guzmán*, Amritlal Sawla**, Daniel Ramírez-Ahedo* * Centro Nacional de Metrología, México. **Physikalisch-Technische
More informationTechnical Protocol of the CIPM Key Comparison CCAUV.V-K5
Technical Protocol of the CIPM Key Comparison CCAUV.V-K5 2017-03-06 revised 2018-02-13 (changed schedule) Task and Purpose of the Comparison According to the rules set up by the CIPM MRA the consultative
More informationIn-vacuum realisation of the new definition of the kilogram. Stuart Davidson, National Physical Laboratory, UK JRP Coordinator - NewKILO
In-vacuum realisation of the new definition of the kilogram Stuart Davidson, National Physical Laboratory, UK JRP Coordinator - NewKILO 1 The SI unit of Mass The kilogram is the unit of mass; it is equal
More informationOn the possible future revision of the SI
Bureau International des Poids et Mesures On the possible future revision of the SI Martin Milton (Director) and Michael Stock (Director of Electricity and Mass) BIPM 2 nd July 2013 Bureau International
More informationA 60 MN build-up force transfer system
A 60 MN build-up force transfer system Li Wansheng, Li Qingzhong, Zhao Yucheng, Sun Yunhai, and Wang Jianguo Shandong Province Institute of Metrology(SDIM), China,liwansh@163.com Fujian Province Institute
More informationFINAL REPORT OF THE BILATERAL COMPARISON OF THE CALIBRATIONS OF STANDARD WEIGHTS BETWEEN CENAM-MEXICO AND INEN-ECUADOR SIM.M.M-S4 (SIM.7.
FINAL REPORT OF THE BILATERAL COMPARISON OF THE CALIBRATIONS OF STANDARD WEIGHTS BETWEEN CENAM-MEXICO AND INEN-ECUADOR (SIM.7.42) 1 Luis Omar Becerra, 2 René Chanchay 1 Centro Nacional de Metrología (CENAM),
More informationCalibration Traceability Guidelines
Calibration Traceability Guidelines Check the website of accrediting bodies for the accredited laboratories individual scope of accreditation www.a2la.org ts.nist.gov/standards/accreditation/index.cfm
More informationImplementation of MRA NMIs, BIPM,RMO-TCs Improvement of Global Measurement Standards NMIs, BIPM
CCM Progress Report for 2003-2007 Mass and Related Quantities Implementation of MRA NMIs, BIPM,RMO-TCs Improvement of Global Measurement Standards NMIs, BIPM. Structure & functions 2. Progress in CIPM-KC
More informationForce Key Comparison EUROMET.M.F-K2. (50 kn and 100 kn) EURAMET Project No 518. Final Report. 14 July Pilot: NPL, United Kingdom
Force Key Comparison EUROMET.M.F-K2 (50 kn and 100 kn) EURAMET Project No 518 Final Report 14 July 2014 Pilot: NPL, United Kingdom Co-authors: Renato Reis Machado (INMETRO, Brazil), Petr Kašpar (CMI, Czech
More informationMorehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web: sales:
Morehouse 1 Morehouse Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA 17403 PH: 717-843-0081 web: www.mhforce.com sales: edlane@mhforce.com 2 This presentation will cover the calibration
More informationFinal Report on the Torque Key Comparison CCM.T-K2 Measurand Torque: 0 kn m, 10 kn m, 20 kn m Dirk Röske 1), Koji Ogushi 2)
Final Report on the Torque Key Comparison CCM.T-K Measurand Torque: kn m, 1 kn m, kn m Dirk Röske 1), Koji Ogushi ) 1) ) Dirk RÖSKE Physikalisch-Technische Bundesanstalt Department 1. Solid Mechanics orking
More informationEURAMET Project 858: Hydrostatic weighing exchange of experiences. Project outline
EURAMET Project 858: Hydrostatic weighing exchange of experiences Project outline A bilateral comparison has been carried out between the national measurement institutes INRIM, Italy and IPQ, Portugal,
More informationWater Vapour Effects in Mass Measurement
Water Vapour Effects in Mass Measurement N.-E. Khélifa To cite this version: N.-E. Khélifa. Water Vapour Effects in Mass Measurement. Measurement. Water Vapour Effects in Mass Measurement, May 2007, Smolenice,
More informationINVESTIGATION OF IMPACT HAMMER CALIBRATIONS
IMEKO 23 rd TC3, 13 th TC5 and 4 th TC22 International Conference 30 May to 1 June, 2017, Helsinki, Finland INVESTIGATION OF IMPACT HAMMER CALIBRATIONS M. Kobusch 1, L. Klaus 1, and L. Muñiz Mendoza 2
More informationForce/Torque measuring facility for friction coefficient and multicomponent
DOI 10.516/sensor013/A1. Force/Torque measuring facility for friction coefficient and multicomponent sensors S. Baumgarten 1, D. Röske 1, H. Kahmann 1, D. Mauersberger 1 and R. Kumme 1 1 Physikalisch-Technische
More informationINVESTIGATION OF THE CALIBRATION CAPABILITIES OF A 1 KN M AND 10 KN M REFERENCE CALIBRATION MACHINE
IMEKO 23 rd TC3, 13 th TC5 and 4 th TC22 International Conference 30 May to 1 June, 2017, Helsinki, Finland INVESTIGATION OF THE CALIBRATION CAPABILITIES OF A 1 KN M AND 10 KN M REFERENCE CALIBRATION MACHINE
More informationTraceable Mass Determination and Uncertainty Calculation
Traceable Mass Determination and Uncertainty Calculation Falko Hilbrunner, Thomas Fehling, Siego Mühlich, Mario Schreiber Sartorius Lab Instruments GmbH Weender Landstrasse 94-108 Goettingen, Germany ABSTRACT
More informationINTERLABORATORY MASS COMPARISON BETWEEN LABORATORIES BELONGING TO SIM SUB-REGIONS COORDINATED BY CENAM (SIM.7.31a & SIM.7.31b)
INTERLABORATORY MASS COMPARISON BETWEEN LABORATORIES BELONGING TO SIM SB-REGIONS COORDINATED BY CENAM (SIM.7.31a & SIM.7.31b) Jorge Nava 1, Luis O. Becerra 1, Tweedsmuir Mitchell, Mairy Sanz, Olman Ramos
More informationTHE UNCERTAINTY OF MEASUREMENT IN CALIBRATION USING A COMPARISON FORCE STANDARD MACHINE
THE UNCERTAINTY OF MEASUREMENT IN CALIBRATION USING A COMPARISON FORCE STANDARD MACHINE Adrian Gherasimov 1, Eugen Ghita 1 Romanian Bureau of Legal Metrology, Force Laboratory Timisoara, Romania POLITEHICA
More information35th Annual GCSSEPM Foundation Bob F Perkins Research Conference 2016
35th Annual GCSSEPM Foundation Bob F Perkins Research Conference 2016 Mesozoic of the Gulf Rim and Beyond: New Progress in Science and Exploration of the Gulf of Mexico Basin Houston, Texas, USA 8 9 December
More informationUncertainty of Calibration. Results in Force Measurements
Publication Reference EAL-G Uncertainty of Calibration Results in Force Measurements PURPOSE This document has been produced to improve the harmonization in determination of uncertainties in force measurements.
More informationNIST ELECTROSTATIC FORCE BALANCE EXPERIMENT
NIST ELECTROSTATIC FORCE BALANCE EXPERIMENT John A. Kramar, David B. Newell, and Jon R. Pratt National Institute of Standards and Technology, Gaithersburg, MD, USA We have designed and built a prototype
More informationWATT BALANCES AND THE FUTURE OF THE KILOGRAM
WATT BALANCES AND THE FUTURE OF THE KILOGRAM Michael Stock Bureau International des Poids et Mesures (BIPM) Pavillon de Breteuil, 92312 Sèvres CEDEX, France Tel.: +33 1 4507 7070 Fax: +33 1 4534 2021 email:
More informationBIPM Workshop on Challenges in Metrology for Dynamic Measurement: Speaker Introductions. BIPM, Sèvres November 2012
BIPM Workshop on Challenges in Metrology for Dynamic Measurement: Speaker Introductions BIPM, Sèvres 15-16 November 2012 Title: Requested reliability of dynamic mechanical measurement in mobility, from
More informationForce Key Comparison APMP.M.F-K2.a and APMP.M.F-K2.b (50 kn and 100 kn) Final Report 6 August Pilot: KRISS, Republic of Korea Yon-Kyu Park
Force Key Comparison APMP.M.F-K2.a and APMP.M.F-K2.b (50 kn and 100 kn) Final Report 6 August 2018 Pilot: KRISS, Republic of Korea Yon-Kyu Park Muktar Sawi (NMIM) Seif M. Osman (NIS) S.S.K.Titus (NPLI)
More informationAn Electromagnetic Force Balance Experiment for Measurement Science Education
An Electromagnetic Force Balance Experiment for Measurement Science Education L M Faller and H Zangl Institute of Smart System Technologies, Sensors and Actuators, Alpen-Adria-Universitaet Klagenfurt,
More informationINTERNATIONAL COMPARISON OF WATER TRIPLE POINT CELLS LEADING TO A MORE PRECISE DEFINITION OF THE KELVIN
INTERNATIONAL COMPARISON OF WATER TRIPLE POINT CELLS LEADING TO A MORE PRECISE DEFINITION OF THE KELVIN Michael Stock and Stéphane Solve Bureau International des Poids et Mesures (BIPM) Pavillon de Breteuil,
More informationThe SI in 2019: Traceability Questions for SIM A Presentation to Encourage Discussion and Understanding Alan Steele SIM General Assembly Montevideo,
The SI in 2019: Traceability Questions for SIM A Presentation to Encourage Discussion and Understanding Alan Steele SIM General Assembly Montevideo, Uruguay November 2016 Defining the SI Via Fundamental
More information