CERTIFICATE OF ACCREDITATION
|
|
- Philippa Potter
- 5 years ago
- Views:
Transcription
1 CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, This is to certify that Hards Laboratories cc, t/a Technology Solutions C3 Prospect Close, 43 Regency Drive, R21 Corporate Park Irene 0157, Pretoria, South Africa has been assessed by ANAB and meets the requirements of international standard ISO/IEC 17025:2005 while demonstrating technical competence in the field of CALIBRATION Refer to the accompanying Scope of Accreditation for information regarding the types of calibrations to which this accreditation applies. L Certificate Number Certificate Valid: 04/11/ /28/2020 Version No. 001 Issued: 04/11/2018 This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Hards Laboratories cc, t/a Technology Solutions C3 Prospect Close, 43 Regency Drive, R21 Corporate Park Irene 0157, Pretoria, South Africa Luke Hards Yvette Volschenk Phone +27 (12) Fax +27 (12) CALIBRATION Valid to: March 28, 2020 Certificate Number: L Acoustics and Vibration Sound Pressure Level Meters Sound Pressure Level Calibrators (74 to 114) db 125 Hz to 4 khz (94 and 114) db 1 khz 0.39 db 0.43 db Reference Sound Level Calibrator Reference Sound Level Meter and Acoustic Microphone Chemical Quantities ph meters 2 Conductivity meters 4 ph 7 ph 7.4 ph 10 ph 5 µs 10 µs 100 µs µs µs µs µs ph ph Reference Solutions 0.55 µs 0.56 µs 2.2 µs 4.7µS 5.1 µs 42 µs 380 µs Conductivity Solutions Page 1 of 4
3 Mass and Mass Related Gas Flow Velocity (Anemometry) Gas Flow Velocity 1 (Flow Chambers) Pneumatic Manometers (Gage Pressure) Up to 35 m/s 1.3 % of reading m/s Flow Calculation System with Pitot Tube & Wind Tunnel Up to 35 m/s 2 % of reading m/s Hot Wire Anemometer (-13.5 to 13.5) kpa 9.8 Pa Reference Pressure Gauge Barometers (80 to 108) kpa 49 Pa Reference Barometer Volumetric Gas Flow meters Up to 500 cm 3 /min (0.5 to 50) L/min 0.3 % of reading 0.3 % of reading Reference Flow Meter Photometry and Radiometry Photometric Sources: Illuminance Photometric Sources: Correlated Colour Temperature (Illuminant A - CIE) Incandescent (Bilirubin / Phototherapy) (400 to 500) nm (UV-A) (315 to 400) nm (UV-B) (280 to 315) nm (0 to ) lux 0.89 % of reading lux Reference Photometer K (2 300 to 3 200) K 8.6 K 10 K Reference Photometer Up to 500 µw/cm % of reading µw/cm 2 Reference Radiometer Up to µw/cm % of reading µw/cm 2 Reference Radiometer Up to µw/cm 2 12 % of reading µw/cm 2 Reference Radiometer Page 2 of 4
4 Photometry and Radiometry (UV-C) (100 to 280) nm Photometric Detectors: Illuminance responsivity (Illuminant A CIE) Up to µw/cm 2 12 % of reading µw/cm 2 Reference Radiometer (0 to ) lux 0.89 % of reading lux Reference Photometer Thermodynamic Humidity Solutions, Hygrometers 2 Humidity Measuring 1 Platinum Resistance Thermometers Liquid in Glass Thermometers (Total/Partial Immersion) Digital and Mechanical Thermometry Systems 11 %RH 33 %RH 53 %RH 75 %RH 90 %RH 0.6 %RH % of reading Reference Salts (5 to 95) %RH 0.64 %RH % of reading Humidity meter and chambers (-40 to 650) C 28 mk Reference PRT and Baths (-40 to 300) C 31 mk Reference PRT and Baths (-40 to 650) C 28 mk Reference PRT and Baths Heat / Cold Stress Monitors (-40 to 60) C 82 mk Reference PRT and Baths Thermometry Air Probes (Thermo-hygrometers) Temperature Measure 1 (-40 to 90) C 89 mk (-196 to 0) C (0 to 200) C (200 to 400) C (400 to 650) C 20 mk 27 mk 43 mk 76 mk Reference PRT and Chamber Reference PRT Ice Point 0 ºC 2.9 mk Ice point Gallium Fixed Point Cell C 2.9 mk Gallium Reference Cell Page 3 of 4
5 Calibration and Measurement Capability (CMC) is expressed in terms of the measurement parameter, measurement range, expanded uncertainty of measurement and reference standard, method, and/or equipment. The expanded uncertainty of measurement is expressed as the standard uncertainty of the measurement multiplied by a coverage factor of 2 (k=2), corresponding to a confidence level of approximately 95%. Notes: 1. On-site calibration service is available for this parameter, since on-site conditions are typically more variable than those in the laboratory, larger measurement uncertainties are expected on-site than what is reported on the accredited scope. 2. Nominal values are approximated. 3. This scope is formatted as part of a single document including Certificate of Accreditation No. L Page 4 of 4
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CONTROL COMPANY 12554 Galveston Road Suite B230 Webster, TX 77598 Aaron Judice Phone: 281 482 1714 CALIBRATION Valid To: March 31, 2018
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Compania Nacional de Metrologia S.A.S - Conamet
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 EQUIPMENT SERVICES GROUP, LLC 3269 Hilton Rd. Ferndale, MI 48220 Michael Macauley Phone: 248 227 5310 CALIBRATION Valid To: December
More informationCertificate of Accreditation to ISO/IEC 17025:2005
United States Department of Commerce National Institute of Standards and Technology Certificate of Accreditation to ISO/IEC 17025:2005 NVLAP LAB CODE: 200508-0 Insco Metrology, Inc. Miami, FL is accredited
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 RS CALIBRATION SERVICES, INC. 1047 Serpentine Lane Pleasanton, CA 94566 Mr. Ralph Sabiel Phone: 925 462 4217 CALIBRATION Valid To: April
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: AMC LABS S.A de C.V (Hereinafter called the Organization)
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: C.V. (Calpromsa) (Hereinafter called the Organization)
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 PROTEMP MECHANICAL, INC. 3350 Scott Blvd, Bldg. #3 Santa Clara, CA 95054 Martin L. Reich Phone: 408 244 9821 CALIBRATION Valid To: August
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Ciudad Madero, Tamaulipas, México. C.P. 89520 (Hereinafter
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ALLOMETRICS, INC Bayport Blvd. Seabrook, TX Terry Baldwin Phone: CALIBRATION
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ALLOMETRICS, INC. 2500 Bayport Blvd. Seabrook, TX 77586 Terry Baldwin Phone: 281 474 3329 CALIBRATION Valid To: April 30, 2019 Certificate Number: 2039.01 In
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:. Av. Rio Consulado # 2614, Col. San Juan de Aragón
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 AMERICAN INSTRUMENT CORPORATION Crossroads Centre 702 Rose Drive Hartland, WI 53029 Jeff Quinn Phone: 262 367 4409 CALIBRATION Valid
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Palenque 1 A, Bello Horizonte,. (Hereinafter called
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Asesoría Industrial en Mantenimiento y Calibración
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:. (Hereinafter called the Organization) and hereby
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 MTS FIELD SERVICE 14000 Technology Drive Eden Prairie, MN 55344 Hugh Casper Phone: 518 852 3977 CALIBRATION Valid To: September 30,
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 JEM PRECISION 9615 56 Avenue NW Edmonton, Alberta T6E 0B2 Canada Robert Korthuis Phone: 780-440 1933 CALIBRATION
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: AMC LABS S.A de C.V Av. México # 329 Col. Valle De
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL Lasheila Hayes Phone:
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL 35096 Lasheila Hayes Phone: 205 505 0296 CALIBRATION Valid to: April 30, 2019 Certificate Number:
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 MAC CALIBRATIONS, LLC 13500 Pearl Road, Suite 139, Box 105 Strongsville, OH 44136 William McCarraher Phone: 440 572 1790 CALIBRATION
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALABAMA SCALE & INSTRUMENT MARSHALL, INC. d.b.a. ASI Calibration Labs - Texas 1006 East End Blvd North Marshall, TX 75672 Lawson Hill
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 LAKE SHORE INDUSTRIAL SERVICES, INC. 2230 Caughey Road Erie, PA 16506 Suzanne R. Zuba / James B. Cross Phone: 814 838 3539 CALIBRATION
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: 5225 South 37 th Street, Suite 4, Phoenix, AZ 85040
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 QAL-TEK ASSOCIATES 3998 Commerce Circle Idaho Falls, ID 83401 Travis Snowder Phone: 208 523 5557 CALIBRATION Valid To: January 31, 2019
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. 705.00 Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc., has assessed the Laboratory of: (Hereinafter called the Organization) and
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 FLORIDA METROLOGY, LLC 645 NW Enterprise Dr. Port St. Lucie FL 34986 Ron Kupper Phone: (772)212-7158 CALIBRATION Valid To: October 31,
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE:
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS 38654 CONNIE FOSTER PHONE: 800 327 7727 CALIBRATION Valid To: August 31, 2019 Certificate Number:
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ARCONIC POWER AND PROPULSION RESEARCH CENTER 1500 S. Warner St. Whitehall, MI 49461-1895 Michelle McDonald Phone: 231 894 7586 CALIBRATION
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ALPHAGAGE th Avenue Rockford, IL James Hoard Phone:
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALPHAGAGE 5245 27 th Avenue Rockford, IL 61109 James Hoard Phone: 815 391 6400 CALIBRATION Valid To: August 31, 2018 Certificate Number:
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 POLYMER TESTING INSTRUMENTS, INC. 10 National Drive Fletcher, NC 28732 Larry Eisner Phone: 828 252 1326 CALIBRATION Valid To: June 30,
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Guadalupe, Nuevo León, México. C.P. 67110 (Hereinafter
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 QUALITY PLUS, INC. 170 Grove Street Chicopee, MA 01020 Mark J. Vickers Phone: 413 594 5529 CALIBRATION Valid
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ANÁLISIS POR INSTRUMENTOS Y SOFTWARE PARA S SA DE CV (DBA SOPORTE METROLOGY) 27 Poniente 507, Interior 103, Colonia Chulavista Puebla,
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 POLYMER TESTING INSTRUMENTS, INC. 74 Patton Ave. Asheville, NC 28801 Greg Skory Phone: 828 252 1326 CALIBRATION Valid To: June 30, 2017
More informationScope of Accreditation For ISOLAB Inc. Calibration
Scope of Accreditation For ISOLAB Inc 6260 Hawthorne Dr Windsor, ON N8T 1J9 Pradip Jansari 519-948-8371 In recognition of a successful assessment to ISO/IEC 17025:2005 to the following and Measurement
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 FRANK COX METROLOGY (Formerly CANADIAN CENTRAL GAUGE LABORATORY) 40 West Drive Brampton, Ontario, Canada L6T 3T6 Hilliard Cox Phone: 905 457 9190 CALIBRATION
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 MACHINIST TOOL REPAIR INC. 6484 Grafton Road Valley City, OH 44280 Susan Novak Phone: 330 483 3202 CALIBRATION Valid To: December 31,
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 TRI-STATE INSTRUMENT SERVICE, INC. 3024 Wayne Trace Ft. Wayne, IN 46806 Lynn A. Stroble Phone: 260 456 4545 CALIBRATION Valid To: September
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 FRANK COX METROLOGY (Formerly CANADIAN CENTRAL GAUGE LABORATORY) 40 West Drive Brampton, Ontario, Canada L6T 3T6 Hilliard Cox Phone: 905 457 9190 CALIBRATION
More informationFor the National Voluntary Laboratory Accreditation Program
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 Additel Corporation 2900 Saturn Street Brea, CA 92821 Eric Chavier Phone: 714-998-6899 Fax: 714-998-6999 E-mail: eric.chavier@additel.com URL: http://additel.com
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. GREENSLADE & CO., INC Wenneca Avenue Fort Worth, TX Larry Borowski Phone:
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 GREENSLADE & CO., INC. 2234 Wenneca Avenue Fort Worth, TX 76102 Larry Borowski Phone: 800 435 2657 CALIBRATION Valid To: October 31, 2018 Certificate Number:
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 A.A. JANSSON Inc. 2070 Airport Road Waterford, MI 48327-1204 Justin Frazzini Phone: 248 674 4811 CALIBRATION Valid To: August 31, 2016
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 F. D. HURKA COMPANY 4731 Stockholm Court Charlotte, NC 28273 Charles Jenkins Phone: 704 552 0008 CALIBRATION Valid To: December 31,
More informationDetermination of sound absorption coefficient in impedance tubes according to ISO (2 appendices)
issued by an Accredited Testing Laboratory Date Reference Page 2011-05-16 PX03759-02-5A 1 (3) Contact person Xuetao Zhang Energy Technology +46 10 516 50 21, xuetao.zhang@sp.se SP Wood Technology Att:
More informationIntroductions to RIC-Beijing. NAN Xuejing, CUI Xiai Meteorological Observation Center China Meteorological Administration March,2018
Introductions to RIC-Beijing NAN Xuejing, CUI Xiai China Meteorological Administration March,2018 Contents 1. China Meteorological Administration (CMA) Organization 2. (MOC) Functional Structure Responsibilities
More informationCERTIFICATE OF CALIBRATION
Page 1 of 10 CALIBRATION OF Sound Level Meter: Brüel & Kjær Type 3050-A-040 No: 3050-100751 Id: - Microphone: Brüel & Kjær Type 4189 No: 2621142 Preamplifier: Brüel & Kjær Type 2669 No: 2679073 Supplied
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 LUXOTTICA QUALITY PERFORMANCE LABORATORY - OAKLEY Oakley Inc., One Icon Foothill Ranch, CA 92610 Dr. Jane Wang Phone: 949 672 6874 MECHANICAL Valid To: May
More informationCALIBRATION CENTER. Republic of Turkey. Ministry of Forestry and. Water Affairs. Turkish State Meteorological Service.
Republic of Turkey Ministry of Forest and Water Affairs Republic of Turkey Ministry of Forestry and Water Affairs Turkish State Meteorological Service CALIBRATION CENTER Turkish State Meteorological Service
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: CONMED LABMET S. de R.L. de C.V. (Hereinafter called
More informationCERTIFICATE OF CALIBRATION
Page 1 of 10 CALIBRATION OF Sound Level Meter: Brüel & Kjær Type 3050-A-040 No: 3050-100751 Id: - Microphone: Brüel & Kjær Type 4189 No: 2621142 Preamplifier: Brüel & Kjær Type 2669 No: 2803547 Supplied
More informationFor the National Voluntary Laboratory Accreditation Program
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Navy Primary Standards Laboratory NAVAIR North Island Code 4.12.9 Bldg. 469S P.O. Box 357058 San Diego, CA 92135-7058 Mr. Al Teruel Phone: 619-545-7912 Fax
More informationCONTENT 2. ORGANIZATION 3. SERVICES. instruments. (3)Activities of RIC Tsukuba
1 CONTENT 1. INTRODUCTION 2. ORGANIZATION 3. SERVICES (1)Quality assurance of meteorological instruments (2)Research and development (3)Activities of RIC Tsukuba 2 Meteorological Instruments Center (MIC)
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CLEVELAND SPECIALTY INSPECTION SERVICES, INC. 8562 East Avenue Mentor, OH 44060 James Popovic Phone: 440 974 1818 CALIBRATION Valid
More informationFor the National Voluntary Laboratory Accreditation Program
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Navy Primary Standards Laboratory NAVAIR North Island Code 4.12.9 Bldg. 469S P.O. Box 357058 San Diego, CA 92135-7058 Mr. Al Teruel Phone: 619-545-7912 Fax
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More informationDeFelsko PosiTector Dew Point Meter with Anemometer (DPMA)
Management Procedure 2562 Revision: A Date Issued: March 24, 2017 Date Revised: Calibration Procedure DeFelsko PosiTector Dew Point Meter with Anemometer (DPMA) Table of Contents 1. Introduction and UUC
More information473-SHX Dew Point Mirror
Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable
More information473 Dew Point Hygrometer
gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion
More informationCALIBRATION CERTIFICATE # 503
CALIBRATION CERTIFICATE # 503 Calibration date : 2011-02-23 Certificate issued : 2012-04-18 Company name Company address City, Province, Canada CLAS 2009-02 Calibration of Mass flow meter Micro Motion
More informationAnemometry Anemometer Calibration Exercise
Atmospheric Measurements and Observations II EAS 535 Anemometry Anemometer Calibration Exercise Prof. J. Haase http://web.ics.purdue.edu/~jhaase/teaching/eas535/index.html Class Objectives How is wind
More informationSeries tore word. Acknowledgements
Series tore word p. xi Preface p. xiii Acknowledgements p. xv Disclaimer p. xvii Introduction p. 1 The instrumental age p. 2 Measurements and the climate record p. 2 Clouds and rainfall p. 3 Standardisation
More informationThe Fundamentals of Moisture Calibration
The Fundamentals of Moisture The following guide will provide you with a basic knowledge of humidity calibration, help you to understand your requirements and select an appropriate solution. 1 Why Humidity
More informationSTATUS OF INSTRUMENTS TRACEABILITY IN NMHSs
WORLD METEOROLOGICAL ORGANIZATION COMMISSION FOR INSTRUMENTS AND METHODS OF OBSERVATION OPAG CAPACITY BUILDING CIMO EXPERT TEAM ON REGIONAL INSTRUMENT CENTRES, QUALITY MANAGEMENT SYSTEMS AND COMMERCIAL
More informationg/cm³ DAkkS Calibration Laboratory for Temperature and Density High-precision calibration for temperature and density
High-precision calibration for temperature and density g/cm³ F K C DAkkS Calibration Laboratory for Temperature and Density Accredited DAkkS laboratory (D-K-15223-01-00) for temperature and density measurements
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Sigma Aldrich RTC, Inc. 2931 Soldier Springs
More informationPRODUCT DATA. Sound Intensity Calibrator Type 3541-A. Uses and Features
PRODUCT DATA Sound Intensity Calibrator Type 3541-A Type 3541-A enables calibration of sound intensity measuring instruments by using a coupler designed especially for sound intensity calibrations. Intensity-probe
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Laboratory locations: Schedule of Accreditation 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit 1G Kilroot Business Park Carrickfergus Co Antrim BT38 7PR Contact: Mr R E Hughes Tel:
More informationAutomated volume measurement for weihts using acoustic volumeter
IMEKO 20th TC3, 3rd TC16 and 1st TC22 International Conference Cultivating metrological knowledge 27th to 30th November, 2007. Merida, Mexico. Automated volume measurement for weihts using acoustic volumeter
More informationSpecific Criteria for Calibration Laboratories in Thermal Discipline
NABL 124 National Accreditation Board for Testing and Calibration Laboratories (NABL) Specific Criteria for Calibration Laboratories in Thermal Discipline ISSUE NO. : 06 AMENDMENT NO. : 00 ISSUE DATE:
More informationCRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TEMPERATURE METROLOGY
CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TEMPERATURE METROLOGY Approved By: Chief Executive Officer: Ron Josias Senior Manager: Mpho Phaloane Revised By: Field Manager: Neville Tayler Date
More informationIntroduction of RIC Tsukuba (Japan, RAII)
Introduction of RIC Tsukuba (Japan, RAII) 20 March, 2018 Kouichi NAKASHIMA Scientific Officer Regional Instrument Centre Tsukuba Observing Division, Observing Department Outline 1. Overview of Organization
More informationMason Technology Ltd
Mason Technology Ltd 228 South Circular Road, Dublin 8 Calibration Laboratory Registration number: 043C is accredited by the Irish National Board (INAB) to undertake calibration as detailed in the Schedule
More informationTheory and Design for Mechanical Measurements
Theory and Design for Mechanical Measurements Third Edition Richard S. Figliola Clemson University Donald E. Beasley Clemson University John Wiley & Sons, Inc. New York / Chichester / Weinheim / Brisbane
More informationInterlaboratory Comparison & Proficiency Testing Program
Extended scope for the organization of proficiency tests in accordance with the requirements of ISO/IEC 17043 VSL, the Dutch Metrology Institute, has significantly extended the scope for their accreditation
More informationMeasurement method for the proficiency testing program
APLAC T088 Appendix Measurement method for the proficiency testing program Introductions This measurement method is prepared for use by the APLAC Proficiency Testing Program Photometric measurement of
More informationCertificate of Calibration Sound Level Calibrator
NATacoustic Acoustic Caliration & Testing Laoratory Level, 48A Elizaeth Street., Surry Hills NSW 200 AUSTRALIA Ph: (02) 828 0570 email: service@natacoustic.com.au wesite: www.natacoustic.com.au A division
More informationCALIBRATION REPORT FOR THERMOHYDROMETER
CALIBRATION REPORT FOR THERMOHYDROMETER SAMPLE CUSTOMER S/N: XXXXX Report Number: Y205188 Page 1 of 5 Report No. Y205188 ICL CALIBRATION LABORATORIES, INC. ISO/IEC 17025 and ANSI/NCSL Z540-1 accredited
More informationTechnical Report. Project. The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels.
Technical Report Ref Number C/21387/R01a Date 06 April 2011 Project The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels Prepared for Rockfon Rockwool A/S
More information2.1. Accuracy, n- how close the indication of the thermometer is to the true value.
AASHTO Accreditation Policy and Guidance on Thermometer Selection and Records Revised: January 25, 2018 Revision #: 0 1. Objective 1.1. The purpose of this document is to clearly define acceptance criteria
More informationAckred. nr 1678 Kalibrering ISO/IEC 17025
Calibration Tvinnargatan 25 SE-507 30 Brämhult SWEDEN Phone: +4633 22 56 30 info@kalibrera.se www.kalibrera.se Ackred. nr 1678 Kalibrering ISO/IEC 17025 Our calibration lab is accredited by Swedac for:
More informationLightLab I N T E R N A T I O N A L
Report of Test LL15785 Performance Summary Luminous flux 540 lm Bare Lamp Power 7.76W SHR Nominal 0.75 SHR Maximum 0.79 PREPARED FOR : Indice Ecotech Pty. Ltd., Richmond, VIC 3121. Page 1 of 7 Performance
More informationInterlaboratory Comparison & Proficiency Testing Program
Extended scope for the organization of proficiency tests in accordance with the requirements of ISO/IEC 17043 VSL, the Dutch Metrology Institute, has significantly extended the scope for their accreditation
More informationQuality assurance for sensors at the Deutscher Wetterdienst (DWD)
Quality assurance for sensors at the Deutscher Wetterdienst (DWD) Quality assurance / maintenance / calibration Holger Dörschel, Dr Tilman Holfelder WMO International Conference on Automatic Weather Stations
More informationCERTIFICATE OF CALIBRATION
Page 1 of 5 CERTIFICATE OF CALIBRATION 1K Thermistor CERTIFICATE NO.: MANUFACTURER: Measurement Specialties DATE OF CALIBRATION: 26-Apr-17 TC15249 CUSTOMER: AMBIENT TEMPERATURE: (21 ± 3) C JOB NUMBER:
More informationSiddharth Institute of Engineering & Technology
SIDDHARTH INSTITUTE OF ENGINEERING & TECHNOLOGY :: PUTTUR (AUTONOMOUS) (Approved by AICTE, New Delhi & Affiliated to JNTUA, Anantapuramu) (Accredited by NBA & Accredited by NAAC with A Grade) (An ISO 9001:2008
More informationNIST CERTIFICATION OF ITS-90 FIXED-POINT CELLS FROM K TO K: METHODS AND UNCERTAINTIES
NIST CERTIFICATION OF ITS-90 FIXED-POINT CELLS FROM 83.8058 K TO 1234.93 K: METHODS AND UNCERTAINTIES Gregory F. Strouse National Institute of Standards and Technology, Gaithersburg, Maryland, USA ABSTRACT
More informationMason Technology Ltd
Mason Technology Ltd 228 South Circular Road, Dublin 8 Calibration Laboratory Registration number: 043C is accredited by the Irish National Board (INAB) to undertake calibration as detailed in the Schedule
More informationA Case for Periodic Calibration or Verification of RTDs
A Case for Periodic Calibration or Verification of RTDs If you are experiencing audio problems please call the teleconference number below Phone 650-479-3208 Access code 668 676 434 Your Host and Presenter
More informationPerry Johnson Laboratory Accreditation, Inc. Calibration Scopes of Accreditation
Perry Johnson Laboratory Accreditation, Inc. Calibration Scopes of Accreditation PL-4 Calibration Scopes Revised: 2/17 Page 1 of 19 1.0 INTRODUCTION 1.1 This policy has been developed by PJLA and its technical
More informationMeasurements & Instrumentation. Module 3: Temperature Sensors
Measurements & Instrumentation PREPARED BY Academic Services Unit August 2013 Institute of Applied Technology, 2013 Module Objectives Upon successful completion of this module, students should be able
More informationEA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement
Publication Reference EA-10/11 EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical PURPOSE This document has been produced by EA as a means of giving advice for calibrating
More informationAnemometer Calibration Requirements for Wind Energy Applications
Anemometer Calibration Requirements for Wind Energy Applications Presented y: Rachael Ishaya ryza Wind Lab, Inc., Fairfield, California American Meteorological Society 17th Symposium on Meteorological
More informationInterlaboratory Comparison & Proficiency Testing Program
Extended scope for the organization of proficiency tests in accordance with the requirements of ISO/IEC 17043 VSL, the Dutch Metrology Institute, has significantly extended the scope for their accreditation
More informationNational Voluntary Laboratory Accreditation Program
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Sapphire Technical Solutions, L.L.C. 10230 Rodney St. Pineville, NC 28134 Mr. Ron Wathan Phone: 704-561-3100 x106 Fax: 866-829-1502 E-mail: rwathan@sapphirests.com
More information