SUBMITTAL DATA: 4U36MS2VHB BTU/HR INVERTER DRIVEN MULTI ZONE HEAT PUMP SYSTEM
|
|
- Junior Hawkins
- 6 years ago
- Views:
Transcription
1 SUBMITTAL DATA: 4U36MS2VHB BTU/HR INVERTER DRIVEN MULTI ZONE HEAT PUMP SYSTEM Heating 47 F(Non-ducted/ Duct): Recommended Fuse/breaker Size MCA 30A 23A 34,600 / 33,000 BTU Heating Capacity Range (Non-ducted/ Duct): Operating Range Cooling 14~115 F Heating -4~75 F Cooling (Non-ducted/ Duct): / BTU Cooling Capacity Range(Non-ducted/ Duct): 6,100~36,500 / 6,100~35,000BTU HSPF (Non-ducted/ Duct): 10.0/9.0 at 17 F(Non-ducted/ Duct) 22,000 / 21,000 BTU Maximum Heating Capacity at 17 F (Non-ducted / Ducted) 26,000 / 25,000 BTU Maximum Heating Capacity at 5 F(Non-ducted/ Duct) 24,000 / 23,000 BTU 5000~36000/5000~34000 BTU Rated Power input (Non-ducted/ Duct): 3,770 / 3,590W SEER (Non-ducted/Duct): 18.0 /16.0 EER(Non-ducted/Duct): 9.0/8.5 Outdoor Sound Rating: 56 db(a)
2 Refrigerant Pipe Maximum Pipe length for all 82ft each unit and 230ft Maximum Pipe Height Difference between Indoor and Outdoor 50ft Connection 1/4", 1/4", 1/4", 1/4"(Discharge) 3/8, 3/8, 3/8 1/2 (Suction) Flare Outdoor Unit Compressor DC inverter Driven Twin Rotary 33 1/16x 37 5/16 x 13 3/8in 840 x 948 x 340 mm 39 9/16 x 42 15/16 x 16 5/16 in 1005 x 1090 x 415 mm Outdoor Fan Speed Heat Exchanger Fin type RPM Blue Fin 191.8/167.5lb
3 SUBMITTAL DATA: AW07LC2VH* 7000 BTU/HR WALL MOUNTED INVERTER DRIVEN HEAT PUMP SYSTEM(INDOOR for multi zone) 7,000 BTU 8,000 BTU 11 x 33 5/8 x 8 1/16 in 280 x 855 x 204 mm Unit of dimension: in (mm) 14 x 37 9/16 x 11 in 355 x 954 x 279 mm 26.8/22 lb
4 SUBMITTAL DATA: AW09LC2VH* 7000 BTU/HR WALL MOUNTED INVERTER DRIVEN HEAT PUMP SYSTEM(INDOOR for multi zone) 9,000 BTU 10,000 BTU 11 x 33 5/8 x 8 1/16 in 280 x 855 x 204 mm Unit of dimension: in (mm) 14 x 37 9/16 x 11 in 355 x 954 x 279 mm 26.8 / 22.0 lb
5 SUBMITTAL DATA: AW12LC2VH* BTU/HR WALL MOUNTED INVERTER DRIVEN HEAT PUMP SYSTEM(INDOOR for multi zone) 12,000 BTU 13,000 BTU 11 x 33 5/8 x 8 1/16 in 280 x 855 x 204 mm Unit of dimension: in (mm) 14 x 37 9/16 x 11 in 355 x 954 x 279 mm 26.8/22 lb
6 SUBMITTAL DATA: AW18LC2VH* BTU/HR WALL MOUNTED INVERTER DRIVEN HEAT PUMP SYSTEM(INDOOR for multi zone) 18,000 BTU 19,000 BTU 12 3/4 x 39 1/4 x 9 1/4 in 332 x 997 x 235 mm 15 7/8 x 42 11/16 x 12 15/16 in 403 x 1085 x 329 mm 35.3/28.6 lb Connection 1/4"(Discharge) 1/2 (Suction) Flare
7 SUBMITTAL DATA: AB09SC2VH* 9000 BTU/HR CASSETTE TYPE INDOOR 9,000 BTU 10,000 BTU Chassis 10 1/4 x 22 7/16 x 22 7/16in 260 x 570x 570 mm Chassis 14 15/16 x 28 1/4 x 26 3/4 in 380 x 718 x 680 mm Grill 2 3/8 x 27 9/16 x 27 9/16 in 60 x 700 x700 mm Chassis 4 1/2 x 29 1/8 x 29 1/8 in 115 x 718 x 718 mm 46.3/37.5lb
8 SUBMITTAL DATA: AB12SC2VH* BTU/HR CASSETTE TYPE INDOOR 12,000 BTU 13,000 BTU Chassis 10 1/4 x 22 7/16 x 22 7/16in 260 x 570x 570 mm Chassis 14 15/16 x 28 1/4 x 26 3/4 in 380 x 718 x 680 mm Grill 2 3/8 x 27 9/16 x 27 9/16 in 60 x 700 x700 mm Chassis 4 1/2 x 29 1/8 x 29 1/8 in 115 x 718 x 718 mm 48.5/40.8lb
9 SUBMITTAL DATA: AB18SC2VH* BTU/HR CASSETTE TYPE INDOOR 18,000 BTU 19,000 BTU Chassis 10 1/4 x 22 7/16 x 22 7/16in 260 x 570x 570 mm Chassis 14 15/16 x 28 1/4 x 26 3/4 in 380 x 718 x 680 mm Grill 2 3/8 x 27 9/16 x 27 9/16 in 60 x 700 x700 mm Chassis 4 1/2 x 29 1/8 x 29 1/8 in 115 x 718 x 718 mm 48.5/40.8lb Connection 1/4"(Discharge) 1/2 (Suction) Flare
10 SUBMITTAL DATA: AD07SL2VH* 7000 BTU/HR SLIM DUCT TYPE INDOOR 7,000 BTU 8,000 BTU 7 5/16 x 33 7/16 x 16 9/16 in 185 x 850 x 420 mm 10 7/16 x 40 3/4 x 21 1/4 in 265 x 1035 x 540 mm Wired 47.2/36.8lb
11 SUBMITTAL DATA: AD09SL2VH* 9000 BTU/HR SLIM DUCT TYPE INDOOR 9,000 BTU 10,000 BTU 7 5/16 x 33 7/16 x 16 9/16 in 185 x 850 x 420 mm 10 7/16 x 40 3/4 x 21 1/4 in 265 x 1035 x 540 mm Wired 47.2/36.8lb
12 SUBMITTAL DATA: AD12SL2VH* BTU/HR SLIM DUCT TYPE INDOOR 12,000 BTU 13,000 BTU 7 5/16 x 33 7/16 x 16 9/16 in 185 x 850 x 420 mm 10 7/16 x 40 3/4 x 21 1/4 in 265 x 1035 x 540 mm Wired 47.2/36.8lb
13 SUBMITTAL DATA: AD18SL2VH* BTU/HR SLIM DUCT TYPE INDOOR 18,000 BTU 19,000 BTU 7 5/16 x 46 1/16 x 16 9/16in 185 x 1170x 420 mm 10 5/8 x 53 3/4 x 21 1/4 in 270 x 1365 x 540 mm Wired 61.8/48.5lb Connection 1/4"(Discharge) 1/2 (Suction) Flare
Submittals. Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* Rev.
Submittals Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* C US Intertek For more information visit us: www.haierductless.com www.haierductlesshelp.com
More information3 Port, 2-Ton Outdoor Heat Pump
Job Name: Tag# Submittal Data Sheet 3 Port, 2-Ton Outdoor Heat Pump 3MXS24NMVJU Efficiency SEER EER HSPF Non-Ducted 17.9 12.7 12.5 Ducted 14 9.7 8.2 Mixed 15.95 11.2 10.35 Performance Cooling (Btu/hr)
More informationSUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM
Job Name: System Reference: SUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM M-SERIES Date: GENERAL FEATURES Quiet Operation Optional base pan heater to prevent ice in drain pan Limited
More informationSUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM
Job Name: System Reference: SUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM M-SERIES Date: GENERAL FEATURES Quiet Operation Optional base pan heater to prevent ice in drain pan Limited
More informationDuctless Split Systems Floating Air
Ductless Split Systems Floating Air PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH MODEL
More informationInverter Multi-Split System
Inverter MultiSplit System Specifications Inverter MultiSplit Fan coil unit Fan Coil Unit Model RAVMS3KCVT RAVMS3KCVT RASMS3KCVT RAVM22S3KCVT RAVM24S3KCVT Standard Cooling Capacity (btu/hr) 9,212 12,624
More informationTHE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP
I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER
More informationAIR CONDITIONERS 2016 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units. Online Interactive Edition v.1.
AIR CONDITIONERS 2016 COLLECTION Window Portable Dehumidifier Through The Wall Ductless Split Units Online Interactive Edition v.1.1 2016 COLLECTION AIR CONDITIONERS Stay comfortable in any room with an
More informationENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,
More informationMODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH
MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH No. Part Name Quantity BOM code List Price Remark 1 Panel assembly 1 201132890609 2 Air filter 2 201132890704 5 Display box
More informationEFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz
ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,
More informationVRF Technical Data Book
VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for
More informationSINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H)
SINGLE Technical Data Book Big for Europe (R4A, Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H) History Version Modification Date Remark Ver.1. Release SINGLE Big for Europe.4.3 Ver.1.1 Modification for
More informationREPAIR PARTS. DX17VS Outdoor Inverter. This manual is to be used by qualified technicians only.
REPAIR PARTS DX17VS Outdoor Inverter DX17VSS181AA DX17VSS241AA DX17VSS01AA DX17VSS61AA DX17VSS421AA DX17VSS481AA DX17VSS601AA This manual is to be used by qualified technicians only. 2018 5151 San Felipe
More informationOUTDOOR UNITS. Introduction YMF-C. Introduction. Refrigerant
Introduction Introduction Refrigerant R407C R Series Y series (Heat Pump) R series (Air-cooling) Y series ( Only) Y series (Heat Pump) R series (Air-cooling) Y series ( Only) OUTDOOR UNITS Model Name -YMF-C
More information4HP13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP WARRANTY
4HP13 PRODUCT SPECIFICATIONS 13 S SPLIT SYSTEM HEAT PUMP FORM NO. 4HP13-100 (07/2014) R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer
More informationBrushless DC Variable Speed Compressor Technical Data Sheet
R134a V DC VARIABLE SPEED Brushless DC Variable Speed Compressor Technical Data Sheet General Information Compressor Part Number (Stationary) CASCADE0005 (140 per pallet) Compressor Part Number (Mobile)
More informationBrushless DC Variable Speed Compressor Technical Data Sheet
R134a V DC VARIABLE SPEED Brushless DC Variable Speed Compressor Technical Data Sheet General Information Compressor Part Number (Stationary) CASCADE0006 (140 per pallet) Compressor Part Number (Mobile)
More informationnufacturing Company, L.P San Felipe, Suite
REPAIR PARTS (2,3,4) Multi Zone Heat Pump Outdoor Unit 2MXS18GVJUAA 3MXS24JVJUAA 4MXS32GVJUAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is to
More informationHEAT CONTENT DECREASES U D R HEAT CONTENT INCREASESO. Btu/lb
Pressure (psia) LINES OF CONSTANT ENTHALPY PRESSURE P R E S S U R E R I S E S P R E S S HEAT CONTENT DECREASES U R E D R HEAT CONTENT INCREASESO P S Btu/lb Heat Content Pressure (psia) SATURATION CURVE
More informationAIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL
AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E
More informationDUAL ZONE DUAL ZONE. SPLIT TYPE WALL MOUNTED type MULTI SPLIT TYPE AIR CONDITIONER AIR CONDITIONER
DUAL ZONE MULTI SPLIT TYPE DUAL ZONE AIR CONDITIONER SPLIT TYPE WALL MOUNTED type AIR CONDITIONER Models Indoor units Outdoor unit ASU9D MW09CE AOU8D MR8DCE CONTENTS SPECIFICATIONS........................................
More informationEUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1
EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS FCP 2008 testing procedures FCP acoustical test method pag. 1 CONTENTS 1 - PURPOSE... 3 2 - NORMATIVE REFERENCES... 3 3 - DEFINITIONS... 3 3.1
More informationnufacturing Company, L.P San Felipe, Suite
Mini-Split Heat Pump Outdoor Unit RXS09LVJU RXS12LVJU RXS15LVJU RXS18LVJU RXS24LVJU REPAIR PARTS nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is
More informationAIR COOLED CONDENSING UNIT
EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT Evolution Series BA-503-3 AUS Evolution Air Cooled Condensing Unit Series Content Page Explanation
More informationToday s A/C systems include:
* www.sgvenergywise.org Replac ing your A/C system REQUIRES a permit from your c ity - it s important. WHY? Because A/C (air conditioning) is a SYSTEM, not just one piece of equipment. The thermostat,
More informationAIR COOLED CONDENSING UNIT
NEW EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT NEW EVOLUTION 7 & 8 SERIES BA-506-5 AUS Evolution Air Cooled Condensing Unit Series Content
More informationSound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones
CFA 2018 - Le Havre Sound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones F. Bessaca et P. Cellardb a CETIAT, Domaine Scientifique de la Doua, 25,
More informationEXPLODED DIAGRAM - PARTS VIEW
Power Supply Sales Model: KSIL018-H216-I 208-230V~ / 1ph / 60Hz EXPLODED DIAGRAM - PARTS VIEW This information is to be used by qualify AC technicians only KSIL1816- Drawing No. D2IL16181301 Above information
More informationThermal Process Control Lap 4 Thermal Energy. Notes:
Thermal Process Control Lap 4 Thermal Energy Notes: 1) Temperature Measurement a) Define temperature i) A measure of the amount of heat contained in a solid, liquid, or gas ii) Result of molecular motion
More informationCEILING WALL type SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models
SPLIT TYPE ROO AIR CONDITIONER CEILING WALL type INVERTER odels Indoor unit AWHZLBC AWHZLBC Outdoor unit AOHZLBC AOHZLBC CONTENTS SPECIFICATIONS.................... OUTLINE AND DIENSIONS.......... REFRIGERANT
More information2.0 KEY EQUATIONS. Evaporator Net Refrigeration Effect. Compressor Work. Net Condenser Effect
2.0 KEY EQUATIONS Evaporator Net Refrigeration Effect Q net refrigeration effect [] = (H 1 H 4 ) lb (Refrig Flow Rate) (60) min lb min hr H 1 = leaving evaporator enthalpy lb ; H 4 = entering evaporator
More informationIMPROVING THE PERFORMANCE OF AN AC UNIT USING CFD
3 rd HVAC Contracting Conference Evolution of HVAC Industry International Hotel Doha The City November 25-26, 2018 IMPROVING THE PERFORMANCE OF AN AC UNIT USING CFD F. Moualled Mechanical Engineering Department
More informationR- 410A R-22 Size (tons) Shipping Weight (lbs) WLAU184AA 1-1/ WLAU182AA 1-1/ WLAU244AA. Model /2
EVAPORATOR COILS A COIL - UNCASED R- 410A or R- 22 SYSTEMS 1 1/2 5 Tons WLAU Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification
More informationNozzle diffuser. Dimensions
Nozzle diffuser GTI Dimensions Installation Ød Description GTI is a flexible supply air nozzle that is suitable for ventilation of large areas. The nozzle can be used for both heated and cooled air and
More informationXHDU Cassette type fan-coils for double/four pipe connections 1,98-14 kw HYDRONIC TERMINALS
HYDRONIC TERMINALS XHDU 402 1203 Versions XHDU 2T XHDU-R 2T XHDU 4T XHDE 2T Single coil for double pipe connections Single coil for double pipe connections with heater Double coil for four pipe connections
More informationHydraulic modeling assessment Copyright 2010, Optimized Technical Solutions, LLC
Hydraulic modeling assessment Copyright 2010, Optimized Technical Solutions, LLC Name: Date: Please answer the following questions with the complete piping configuration shown in Figure 1 below. Assume
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASU0CLX ASUCLX Outdoor unit AOU0CLX AOUCLX CONTENTS SPECIFICATIONS.................... DIMENSIONS....................... REFRIGERANT
More informationVariable swirl diffusers
Swirl diffusers, Variable swirl diffuser OD- Application Diffuser is designed for air conditioning of rooms with floor to ceiling highs of to 0 m and high induction requirements. It is suitable for large
More informationPARTS CATALOG. No. OBB702 REVISED EDITION-C. Models
Revision C: MXZ-3C24/3C30/4C36/5C42NA2 and MXZ-2C20/3C24/3C30NAHZ2 have been added. Please void OBB702 REVISED EDITION-B. OUTDOOR INDOOR UNIT UNIT PARTS CATALOG No. OBB702 REVISED EDITION-C Models MXZ-3C24NA
More informationAngular momentum equation
Angular momentum equation For angular momentum equation, B =H O the angular momentum vector about point O which moments are desired. Where β is The Reynolds transport equation can be written as follows:
More informationImpact of Independent Living/Bedroom Thermostat Settings in Residential Variable- Refrigerant Flow Systems
Design & Engineering Services Impact of Independent Living/Bedroom Thermostat Settings in Residential Variable- Refrigerant Flow Systems ET 06.02.01 Report Prepared by: Design & Engineering Services Customer
More informationEnergy Efficient Easy to Install Extended Service Life. Horizontal Direct Drive Blower Coils BUILD YOUR REPUTATION ON OURS
Energy Efficient Easy to Install Extended Service Life Energy efficient compact blower coils Ideal for educational, hospitality, multi-family, or other commercial environments Designed for ducted applications
More information8 10HP Outdoor Units. Are pleased to announce the launch of the NEW 6 Series Digital Inverter 8-10HP
PRODUCT BULLTIN N 6 Series Digital Inverter 810HP 8 10HP s w RV RV w RV RVSM2806T8 *** vailable Q2 2017 *** re pleased to announce the launch of the N 6 Series Digital Inverter 810HP 8 10HP outdoor units
More informationSPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE
SPLIT TYPE ROOM IR CONDITIONER WLL MOUNTED TYPE Indoor unit SU9R SUR Outdoor unit OU9R OUR CONTENTS SPECIFICTIONS.................. DIMENSIONS..................... REFRIGERNT SYSTEM DIGRM... CIRCUIT DIGRM.................
More informationmaintenance-free in continuous duty low-noise space-saving extremely tough Suction capacity in m 3 /h m 3 /h 2500 Suction capacity 30,000 10,000
Suction capacity in m /h m /h 20 2000 1000 0 00 2 200 1 100 10 700 0 0 400 00 200 100 0 100 200 00 400 0 0 700 800 900 1000 1100 Suction pressure auge pressure mbar ELMO- vacuum pumps and compressors convey
More informationMcQuay Climate Control Singer. Incremental. NE, NH, NR Vintages C, D. TYA, TAA Vintages A, B. Last Manufactured: 1999
Replacement Parts List No. 055233900 Revision D 08/2017 McQuay Climate Control Singer Incremental NE, NH, NR 07-18 Vintages C, D TYA, TAA 007-015 Vintages A, B Last Manufactured: 1999 To find your Daikin
More informationRadiant Heating Panel Thermal Analysis. Prepared by Tim Fleury Harvard Thermal, Inc. October 7, 2003
Radiant Heating Panel Thermal Analysis Prepared by Tim Fleury Harvard Thermal, Inc. October 7, 2003 Analysis Objective Perform a thermal test on a small sample of the concrete to determine the Thermal
More informationTable of Contents. Oil Furnace, Low Profile Highboy, OH6 Series 6. Oil Furnace, Low Profile Highboy, OH8 Series 7. Oil Furnace, Lowboy, OL5 Series 8
Table of Contents PAGE N. Air Conditioning Data Sheet Dimensional Coil Table Coil Part Nomenclature - Thermo Pride Brand il Furnace, ow Profile Highboy, H6 Series 6 il Furnace, ow Profile Highboy, H8 Series
More informationWeek 8. Steady Flow Engineering Devices. GENESYS Laboratory
Week 8. Steady Flow Engineering Devices Objectives 1. Solve energy balance problems for common steady-flow devices such as nozzles, compressors, turbines, throttling valves, mixers, heaters, and heat exchangers
More informationB6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS B6VMAX Series Air Handler with TXV 13-19 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) R-410A Refrigerant The B6VMAX Series of air handlers, when combined
More informationGlide Effect on Performance
Glide Effect on Performance ASHRAE, January 2016 Bachir Bella Regis Leportier* ASERCOM Azeotropic Mixtures The azeotropic (refrigerant) mixtures are usually binary mixtures that behave like a pure fluid
More informationENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY*
ENVIRONMENTALLY SOUND REFRIGERANT ENH4X Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS 2 thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum
More informationProduct Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU
CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow Product Data CAPVU A06002 The CAPVU evaporator coils incorporate proven standards for reliable system operation and performance throughout the
More informationREPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA
REPAIR PARTS GPH14 H-SERIES R-0A Package Heat Pumps GPH1424HAA GPH1430HAA GPH1436HAA GPH1442HAA GPH1448HAA GPH1460HAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing
More informationHeat Transfer Enhancement Through Perforated Fin
IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X PP. 72-78 www.iosrjournals.org Heat Transfer Enhancement Through Perforated Fin Noaman Salam, Khan Rahmatullah,
More informationDevelopment and Validation of Flat-Plate Collector Testing Procedures
Development and Validation of Flat-Plate Collector Testing Procedures Report for February, 2007 Focus on Energy (FOE) supports solar thermal systems that displace conventional fuels by offering cash-back
More informationManaging Thermal Gradients on a Supercritical Carbon Dioxide Radial Inflow Turbine. David W. Stevens
Managing Thermal Gradients on a Supercritical Carbon Dioxide Radial Inflow Turbine David W. Stevens dstevens@, Turbine Cooling Historically, a consistent engineering challenge Machine durability Traditional
More informationCase 5 Manual Selection of Water Cooled Condenser and Water Cooler
Case 5 Manual Selection of Water Cooled Condenser and Water Cooler Copy Right By: Thomas T.S. Wan ) Nov. 19, 2010 All Rights Reserved Case Background: This case is to demonstrate the use of manufacturer
More informationGB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY
TECHNICAL SPECIFICATIONS GB5BM Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The GB5BM Series of air handlers, when combined with our heat pump or air conditioner,
More informationBV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton
BV SERIES VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton MAGIC AIRE BV SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.
More informationLentis Pai/Associate Director/Wiwynn
Two Phase Rack Level Liquid Cooling Solution Lentis Pai/Associate Director/Wiwynn A g e n d a Existing Chassis Level Solution Wiwynn Two Phase Immersion Cooling Rack Level Liquid Cooling Solution Overview
More informationPARTS CATALOG MUZ-LN25VGHZ MUZ-LN35VGHZ MUZ-LN50VGHZ OUTDOOR UNIT. No. OBB768. Models CONTENTS SERVICE MANUAL (OBH768) MUZ-LN25VGHZ MUZ-LN35VGHZ
OUTDOOR UNIT PARTS CATALOG No. Models MUZ-LN25VGHZ MUZ-LN35VGHZ MUZ-LN50VGHZ - E1, ER1, ET1 - E1, ER1, ET1 - E1, ER1, ET1 CONTENTS 1. RoHS PARTS LIST 2 SERVICE MANUAL (OBH768) MUZ-LN25VGHZ MUZ-LN35VGHZ
More informationSound Rating of Ducted Air Moving and Conditioning Equipment
AHRI Standard 260 (I-P) 2017 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the
More informationM E 320 Professor John M. Cimbala Lecture 23
M E 320 Professor John M. Cimbala Lecture 23 Today, we will: Discuss diffusers and do an example problem Begin discussing pumps, and how they are analyzed in pipe flow systems D. Diffusers 1. Introduction.
More informationMcQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017
Replacement s List No. 055206700 Revision B 02/2017 McQuay Water Source Heat Pump VF, VG, VP 240-390 Vintage E, F, G Last Manufactured: 1992 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationDUCT type. INVERTER SPLIT TYPE AIR CONDITIONER (50Hz) ARYA24LATN AOYA24LACL. Models Indoor unit Outdoor unit
INVERTER SPLIT TYPE AIR CONDITIONER (0Hz) DUCT type Models Indoor unit Outdoor unit ARYALATN AOYALACL CONTENTS SPECIFICATIONS.................... DIMENSIONS....................... REFRIGERANT SYSTEM DIAGRAM...
More informationNozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.
Nozzles About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement diffusers VAV
More informationTRADE MATH. accurate means to be without error. The word precise means to be exact.
Service Application Manual SAM Chapter 620-119 Section 13B TRADE MATH by Harlan Skip Krepcik, CMS Excerpted from Preparing for the NATE Exam: Core Essentials, published by RSES. INTRODUCTION Math is a
More informationExperimental Investigation of an Environmental Control Unit Utilizing Carbon Dioxide for Heating and Cooling
University of Illinois at Urbana-Champaign Air Conditioning and Refrigeration Center A National Science Foundation/University Cooperative Research Center Experimental Investigation of an Environmental
More informationAR/IA 241 LN 231 Lecture 4: Fundamental of Energy
Faculty of Architecture and Planning Thammasat University A/IA 24 LN 23 Lecture 4: Fundamental of Energy Author: Asst. Prof. Chalermwat Tantasavasdi. Heat For a specific substance, the heat given to the
More informationApplied Thermodynamics for Marine Systems Prof. P. K. Das Department of Mechanical Engineering Indian Institute of Technology, Kharagpur
Applied Thermodynamics for Marine Systems Prof. P. K. Das Department of Mechanical Engineering Indian Institute of Technology, Kharagpur Lecture No - 03 First Law of Thermodynamics (Open System) Good afternoon,
More informationEND4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY*
ENVIRONMENTALLY SOUND REFRIGERANT VERTICAL EVAPORATOR COILS ALL N COIL MODELS 1½ thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum fin N coil with latest high tech fin
More informationDepartment of Energy Fundamentals Handbook. THERMODYNAMICS, HEAT TRANSFER, AND FLUID FLOW, Module 3 Fluid Flow
Department of Energy Fundamentals Handbook THERMODYNAMICS, HEAT TRANSFER, AND FLUID FLOW, Module 3 REFERENCES REFERENCES Streeter, Victor L., Fluid Mechanics, 5th Edition, McGraw-Hill, New York, ISBN 07-062191-9.
More informationNumerical Modelling of Twin-screw Pumps Based on Computational Fluid Dynamics
Numerical Modelling of Twin-screw Pumps Based on Computational Fluid Dynamics 6-8 th March 2017 Dr Sham Rane, Professor Ahmed Kovačević, Dr Di Yan, Professor Qian Tang, Centre for Compressor Technology,
More informationvector H. If O is the point about which moments are desired, the angular moment about O is given:
The angular momentum A control volume analysis can be applied to the angular momentum, by letting B equal to angularmomentum vector H. If O is the point about which moments are desired, the angular moment
More information88. Noise control and sound quality evaluation of outdoor unit of split air-conditioner
88. Noise control and sound quality evaluation of outdoor unit of split air-conditioner Chengjun Wu 1, Xiaofei Lei 2 School of Mechanical Engineering, Xi an Jiaotong University, Xi an, P. R. China 2 Corresponding
More informationPlain diffuser. Dimensions
Dimensions Ø U Ød B C Ø E Ø A Description is a circular diffuser with an unperforated adjustable face plate and can be used for both supply and extract air. The diffuser can be switched between horizontal
More informationReadings for this homework assignment and upcoming lectures
Homework #3 (group) Tuesday, February 13 by 4:00 pm 5290 exercises (individual) Thursday, February 15 by 4:00 pm extra credit (individual) Thursday, February 15 by 4:00 pm Readings for this homework assignment
More informationApplied Fluid Mechanics
Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and
More informationAir distribution systems. Linear whirl outlet WL...
Air distribution systems Linear whirl outlet WL... DS 0 E 1.013 Preliminary remarks Mode of operation The linear whirl outlet generates turbulent mixing ventilation. It can be installed on or in a wall
More informationREPAIR PARTS. GPH H-SERIES Package Heat Pumps
REPAIR PARTS GPH H-SERIES Package Heat Pumps GPH1324HAB GPH1324HAC GPH1324HAD GPH1324HA GPH1330HAB GPH1330HAC GPH1330HAD GPH1330HA GPH1336HAB GPH1336HAC GPH1336HAD GPH1336HAE GPH1336HA GPH1342HAB GPH1342HAC
More informationOpen PRAIRIE: Open Public Research Access Institutional Repository and Information Exchange
South Dakota State University Open PRAIRIE: Open Public Research Access Institutional Repository and Information Exchange Theses and Dissertations 2016 The Effects of Diffuser Exit Velocity and Distance
More informationProduct Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow
CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow Product Data CN(P,R)VP CN(P,R)VT (Transition) A06008 A06007 This vertical design N -coil is a furnace
More informationThermodynamics I Spring 1432/1433H (2011/2012H) Saturday, Wednesday 8:00am - 10:00am & Monday 8:00am - 9:00am MEP 261 Class ZA
Thermodynamics I Spring 1432/1433H (2011/2012H) Saturday, Wednesday 8:00am - 10:00am & Monday 8:00am - 9:00am MEP 261 Class ZA Dr. Walid A. Aissa Associate Professor, Mech. Engg. Dept. Faculty of Engineering
More informationMAE 11. Homework 8: Solutions 11/30/2018
MAE 11 Homework 8: Solutions 11/30/2018 MAE 11 Fall 2018 HW #8 Due: Friday, November 30 (beginning of class at 12:00p) Requirements:: Include T s diagram for all cycles. Also include p v diagrams for Ch
More informationCHAPTER 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES
Thermodynamics: An Engineering Approach 8th Edition in SI Units Yunus A. Çengel, Michael A. Boles McGraw-Hill, 2015 CHAPTER 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES Lecture slides by Dr. Fawzi Elfghi
More informationinter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE
Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 1.4 ON TWIN-SCREW COMPRESSOR
More informationELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz
ELMO- Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz Selection diagram vacuum operation Selection diagram compressor operation The performance curves are valid for pumping air at 15 C at the inlet
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit RC-36HB RO-36HC RC-45HB RO-45HB
SPLIT TYPE AIR CONDITIONER CASSETTE type (0Hz) Models Indoor unit Outdoor unit RC-6HB RO-6HC RC-HB RO-HB CONTENTS SPECIFICATIONS......................... OUTLINE AND DIMENSIONS............... CIRCUIT DIAGRAM.......................
More informationDensity of Air & Water Part 2
Density of Air & Water Part 2 Here is part 2 from Michael Housh from Housh Home Energy in Ohio. Thanks Michael! This is part two in a series on a deeper look into the Sensible Heat Rate Equations. The
More informationDimensions. Order code. Materials and finish. lindab ceiling diffusers
LKP Description LCP is a flush-mounted square diffuser with a circular unperforated face plate for installation in ceiling systems. LCP can be used for both supply and exhaust air. LCP is suitable for
More informationDUCT type (50Hz) CASSETTE type (50Hz)
SPLIT TYPE AIR CONDITIONER DUCT type (0Hz) CASSETTE type (0Hz) Models Indoor unit Outdoor unit DUCT type RD-6CA RD-6HA RO-6CA RO-6HA CASSETTE type RC-6CA RC-6HA RO-6CA RO-6HA C O N T E N T S SPECIFICATIONS
More informationRETA Book 1 Chapter 1 Fundamental Items
RETA Book 1 Chapter 1 Fundamental Items Peter Thomas, P.E. Resource Compliance RETA Certification Levels CARO Certified Assistant Refrigeration Operator CARO is an entry-level credential that is designed
More informationTwo mark questions and answers UNIT I BASIC CONCEPT AND FIRST LAW SVCET
Two mark questions and answers UNIT I BASIC CONCEPT AND FIRST LAW 1. What do you understand by pure substance? A pure substance is defined as one that is homogeneous and invariable in chemical composition
More informationSpring_#7. Thermodynamics. Youngsuk Nam.
Spring_#7 Thermodynamics Youngsuk Nam ysnam1@khu.ac.kr You can t connect the dots looking forward; you can only connect them looking backwards. So you have to trust that the dots will somehow connect in
More informationIn the Psy. Ch., plot point o, r, h r = 51.0 kj/kg, h o = 85 kj/kg
& Marking Scheme (Page 1 of 8 ) 1. (a)(i) In the Psy. Ch., plot point o, r, h r = 51.0 kj/kg, h o = 85 kj/kg SHR = rs/rt = 63/70 = 0.9 Draw a line with SHR= 0.9 from r and intercept at s or cc in such
More informationFachgesprach 12. HVAC Pumps. For Project Managers
Fachgesprach 12 HVAC Pumps For Project Managers WTF Philosophy: If you don t remember a certain formula, it's OK - you can always GoogleTheS h i t. But bad engineering CONCEPTS can hurt you. WTF Institute
More informationPARTS CATALOG MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2
Revision E: MUZ-HJ25/50- E2, ER2, ET2, MUZ- HJ E3, ER3, ET2 and MUZ-HJ60/71- E2 have been added. Please void OBB648 REVISED EDITION-D. OUTDOOR UNIT PARTS CATALOG HFC utilized R410A No. OBB648 REVISED EDITION-E
More informationPhysics 9 Monday, November 5, 2018
Physics 9 Monday, November 5, 2018 For today, you read Eric Mazur s chapter 22 (Electric Interactions) PDF on Canvas. For Wed., read Giancoli ch16 (electric charge & electric field) I have a large number
More information