1 3933 US Route 11 Cortland, NY Telephone: (607) Facsimile: (607) Intertek Project No. G Johan Kuikman Phone: Fortis Wind Energy BV Aduarderdiepsterweg 9b EL-HOOGKERK Netherlands Subject: Acoustic noise emission test report for the Fortis Wind Energy Montana 5 kw grid-tied horizontal axis wind turbine tested at the Intertek Small Wind Turbine Regional Test Center (RTC). Dear Ms. Huskey, T This Test Report represents the results of the evaluation and tests of the above referenced equipment under Intertek Project No. G , as part of the US Department of Energy and National Renewable Energy Laboratory (DOE/NREL) Subcontract Agreement No. AEE , to the requirements contained in the following standard: IEC Wind Turbine Generator Systems Part 11: Acoustic Noise Measurement Techniques Edition 2.1, November This investigation was authorized by signed proposal number Q , May 25, A production sample was installed at the Intertek RTC on January 14 th, Acoustic noise measurements were taken on four separate days in April and May of This Test Report completes the acoustic testing phase of the Fortis Montana under Intertek Project No. G If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the signatories on this report. Please note, this Test Report on its own does not represent authorization for the use of any Intertek certification marks. Completed by: Joseph Spossey Reviewed by: Tom Buchal Title: Project Engineer Title: Senior Staff Engineer Signature: Signature Page 1 of 35 This report is for the exclusive use of Intertek s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek s responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program.

2 Fortis Wind Energy BV Wind Turbine Generator System Acoustic Noise Emissions Test Report for the Fortis Wind Energy Montana at Intertek Small Wind Regional Test Center Page 2 of 35

3 1.0 Background This test is conducted as part of the DOE/NREL Subcontract Agreement No. AEE for the testing of small wind turbines at regional test centers. The Fortis Wind Energy, B.V., Montana Wind Energy System was accepted into this program by Intertek and DOE/NREL. The full scope of type testing provided by Intertek for the Fortis Montana horizontal-axis wind turbine is covered by this agreement. This Test Report is a summary of the results of acoustic noise emission testing, and is one of four tests to be performed on the Fortis Montana turbine; the other three being duration, safety and function, and power performance. Results for these other tests are summarized in their respective Test Reports. The Fortis Montana turbine is installed at Test Station #2 at the Intertek RTC in Otisco, NY. The Fortis Montana is designed for grid-connected power delivery, with a maximum power output of 5 kw. It is classified as a Class II upwind direct drive turbine with speed and power control through horizontal furling and electric dampening. The Fortis Montana has a three-phase brushless variable speed generator with permanent magnet excitation that is rated for operation at 220V. The turbine system has multiple output configurations; for testing at the Intertek RTC, the output and grid interconnect is provided by a WB5000-US WindyBoy inverter at 240V single phase. The tower and foundation were designed and approved by Nello Corporation. The designs were based off of the Subsurface Investigation and Geotechnical Evaluation detailed in Atlantic Testing Laboratories report number CD3119E The electrical network at the testing location is single/split phase 120/240 VAC at 60 Hz. Refer to the wiring diagrams in Appendix B for additional detail. A summary of the test turbine configuration and manufacturer s declared ratings can be found in Table 1 below. 2.0 Test Objective The purpose of the acoustic test is to characterize the noise emissions of the Fortis Wind Energy Montana. This involves using measurement methods appropriate to the noise emission assessment at locations close to the turbine, in order to avoid errors due to sound propagation, but far enough away to allow for the finite source size. The evaluation herein characterizes the wind turbine noise with respect to a range of wind speeds and directions. Characterizations of the turbine s apparent sound power level, 1/3 octave bands, and tonality are made. 3.0 Test Summary Testing and analysis of the Fortis Wind Energy Montana was performed in accordance with the edition 2.1 of IEC Method 2 for the direct measurement of wind speed was employed versus determination of wind speed from the measured power curve. This method was chosen due to the ability to accurately measure wind speed at hub height because of the meteorological tower installed per IEC Power Performance Measurements of Electricity Producing Wind Turbines. Figure 1 below is the summary of results from the acoustic noise test conducted on the Fortis Montana turbine. In Figure 1, wind speed is standardized to reference conditions at 10 m above ground level and a roughness length of 0.05 m. The amount of test data analyzed to produce Figure 1 is sufficient to meet the database requirements of the Standards. Page 3 of 35

4 Figure 1 Acoustic noise test results summary Page 4 of 35

5 Turbine manufacturer Model Rated Electrical Power (kw) Rotor Diameter (m) Hub Height (m) Fortis Wind Energy B.V. Montana 5.0 kw 5.0 m (16.4 ft.) Verified by Intertek as m (16 ft 6.5 in) 36.8 m (120 ft 9 in) Swept Area (m 2 ) m 2 (211.3 ft 2 ) Distance from rotor centre to tower axis 0.43 m (1 ft 5 in) Tower Type(s) Lattice IEC SWT Class (I, II, III, or IV) II Cut-in Wind Speed 2.5 m/s (5.6 mph) Rated Wind Speed 12 m/s (26.8 mph) Survival Wind Speed 60 m/s (134 mph) Generator identification Fortis / Inensus 5 kw Serial # Generator specifications 5 kw, 220 VAC, 50 Hz 3-phase, 350 RPM Inverter identification SMA, Windy Boy WB5000US Serial #: Inverter specifications 5000 W, 240VAC Single phase, 60 Hz UL 1741 Listed Rectifier/Controller identification Windy Boy, WBP-Box 500 Serial #: Input max 3 phase 440 VAC, 11.5 A Rectifier/Controller specifications Output max 500 VDC, 30 A IP54 Outdoor (mounted indoors) Diversion load identification Heine Resistors, RFB 6-7 Serial #: c Diversion load specifications 6kW, 42 Ω ± 10%, IP 23 (mounted outdoors) Active brake switch identification Inensus Serial #: Active brake switch specifications 400 V, 15 A IP40 (mounted indoors) Blade identification Fortis Serial #s: 3311, 3312, 3313 Blade specification Fiberglass epoxy, NACA 4415 airfoils Rotor speed range (rpm) Fixed or variable pitch Fixed Number of Blades 3 Blade Tip Pitch Angle (deg) 10 Table 1 Test turbine configuration and manufacturer s declared specifications 4.0 Engineering Judgments or Deviations A linear regression was used for the determination of the background sound pressure levels, as opposed to the 4 th order regression mentioned in the Standard. No added uncertainty is necessary to be added resulting from this deviation, as the linear regression showed a higher correlation to the measured data pairs of background noise data. Page 5 of 35

6 5.0 Test Site Description The RTC has class IV winds, and can accommodate turbines that produce 120V or 240V, 60 Hz power. It is on a hilltop, with previous agricultural land use, near the township of Otisco, NY. It was surveyed, analyzed and developed to be a test site for Intertek s customers. The Fortis Montana is installed and tested at RTC test station #2, which has no prominent obstructions to the east, south, or west as determined by obstacle assessment in accordance with the first edition of IEC Wind Turbines Part 12-1: Power performance measurements of electricity producing wind turbines, dated December The roughness length of the test location is estimated at 0.05 meters for farmland with some vegetation. This value is given in Table 1 of IEC The meteorological equipment tower is located due south of the turbine, 41 ft from the turbine, exactly 2.5 times the diameter of the rotor. Figure 2 below shows the layout of the RTC and identifies the test location in the red box. The elevation data points are plotted in 10 meter intervals. Figure 3 below shows a zoomed view of the turbine and meteorological tower locations. The Fortis Montana was the only turbine installed at the RTC over the duration of this test; therefore no turbines were in operation during the measurement program. Figure 2 - Intertek RTC topographical survey Page 6 of 35

7 Figure 3 below shows the location of the Fortis Montana and its measurement tower ( Met2 ). Figure 3 - Fortis Montana and meteorological tower (Met2) locations The Fortis Montana turbine was the only turbine installed at the RTC during the measurement period; therefore no turbines were in operation during the measurement program. The only noise source identified during the measurement period was the interstate that runs north-south in the valley 2.5 miles to the east of the test site. The background noise generated is consistent in all recordings and has no effect on turbine noise data as it is removed in background correction in accordance with the Standard. Page 7 of 35

8 6.0 Test Equipment The test equipment utilized during the acoustic noise measurement program can be found in the Appendix. The meteorological equipment utilized during this test program is in compliance with the IEC Figure 4 below identifies meteorological equipment locations on the meteorological mast. Calibration certifications of all equipment used during testing are kept on file in the Intertek project file. Figure 4 Instrument locations on the meteorological mast Page 8 of 35

9 7.0 Test Procedure 7.1 General The general method applied during this test program directly follows the method described in IEC :2006. The main purpose is to provide apparent A-weighted sound power levels and spectra at integer wind speeds from 6 to 10 m/s. As mentioned in Section 3.0 above, the only deviation from the standard is that Method 2, which is also described in the standard, was followed. Method 2 allows for direct measurement of wind speed by an anemometer, versus the determination of wind speed from the measured power curve. This is Intertek s preferred method, considering all meteorological measurements are being taken by the met tower per the power performance test requirements. Correction to reference conditions was carried out per the standard. Acoustic noise data was gathered on four separate days during the months of April and May in On all four days, winds were primarily out of the South, ranging from 156 to 232 with respect to true North. Me teorological and wind turbine data has been gathered continuously since commissioning of the Montana on February 4 th, The anemometer for wind speed measurement was located at m (118 ft 3 in) above ground level. Table 2 below shows the date, time, microphone location, and allowable wind sector for each day acoustic measurements were taken. Date Start End Microphone Allowable Horizontal Distance Time Time Location Sector 22-Apr-11 12:29:00 16:34: m (128 feet) 13 9 to Apr-11 14:20:00 15:55: m (128 feet) 16 3 to May-11 12:20:00 17:00: m (128 feet) 15 1 to May-11 12:15:00 13:42: m (128 feet) 211 to 241 Table 2 Acoustic measurement information 7.2 Measurements and procedures Measurement positions In order to fully characterize the noise emissions of the Fortis Montana, the following measurement positions are required Acoustic measurement position Only the required reference microphone location, as defined in Figure 5 below, is used for the acoustic measurement location. The direction of the position is accurate within ±15 relative to the wind direction at the time of measurement. The horizontal distance from the wind turbine tower vertical centreline to the reference microphone position, R 0, was determined using Equation 1 below. In Equation 1, D is the diameter of the turbine and H is the hub height of the turbine. Using the specified tolerance of 20%, this requires the reference microphone location to be within the range of 32.5 m to 48.7 m (106.5 ft to ft). Equation 1 Calculating R 0 according to Equation 1 results in a length of 40.6 m ( ft). At 40.6 m the inclination angle φ was greater than 40, and thus outside of the requi red range of 25 to 40. In order to obtain an inc lination angle of 39 a reference microphone distance of 146 feet was needed. This value is within the allowable range mentioned above. Page 9 of 35

10 To minimize influence due to the edges of the reflecting board on the measurement results, the board was positioned flat on the ground. The edges and gaps under the board were levelled out by means of sand. Figure 5 Standard pattern for microphone measurement positions (plan view) Source: IEC : Edition 2.1, November Wind speed and direction measurement position The test anemometer and wind direction transducer are the same instruments mounted on the permanent meteorological mast for power performance testing according to the first edition of IEC Wind turbines Part 12-1: Power performance measurements of electricity producing wind turbines, dated December The location of the instrumentation on the permanent meteorological tower is shown in Section 6 above. The sensors are installed at locations that are compliant with the requirements of the Standards. Method 2 of IEC is used for the direct measurement of wind speed by the anemometer on the permanent meteorological tower. Figure 6 below was used to determine the acceptability of the permanent meteorological tower location. Given that the anemometer is mounted at the same hub height as the turbine, the angle β as defined in Figure 6 is 90. Page 10 of 35

11 During the measurement periods identified in Table 2, the anemometer was not in the wake of any portion of any other wind turbine or structure. Figure 6 Allowable region for meteorological mast position as a function of β (plan view) Source: IEC : Edition 2.1, November Acoustic measurement procedures Acoustic measurements at wind speeds up to 15 m/s at hub height were made for the purpose of determining apparent sound power levels, one-third octave band levels, and the presence of any tonal characteristics. For all acoustic measurements taken during the periods indicated in Table 2 above, the following considerations apply: The complete measurement chain was calibrated at least at one frequency before and after the measurements, or if the microphone was disconnected during repositioning All acoustical signals were recorded and stored for later analysis Periods with intruding intermittent background noise (as from an aircraft) were omitted from the database With the wind turbine stopped, and using the same measurement setup, the background noise was measured immediately before or after each measurement series of wind turbine noise and during similar wind conditions The equivalent continuous A-weighted sound pressure level and one-third octave band spectrum were measured at the microphone locations described in Table 2 above. Each measurement for A-weighted sound pressure level and one-third octave band spectrum was integrated over a period of 1 minute for both turbine and background Page 11 of 35

12 noise, as this is the required averaging interval of the Standard. One-third octave bands with centre frequencies ranging from 20 Hz to 16 khz were recorded, but values centred on 50 Hz to 10 khz are reported per the requirements of the standard. A minimum of 3 measurements within ±0.5 m/s at each integer wind speed were required for both sound pressure and one-third octave analysis Non-acoustic measurements Wind speed was determined according to Method 2 of the IEC standard, for the determination of wind speed with an anemometer. This is the preferred method for analysis in compliance with the Standards. The wind speed measurement results were adjusted to a height of 10 m and the reference roughness length of 0.05 m as described in section 7.3 below. Direct measurement of wind speed by an anemometer was used for both turbine plus background noise and background noise measurements. Wind speed data was averaged over a 1 minute period to align with the averaging of acoustic measurements. Wind direction was measured by a wind direction vane to ensure that measurement locations are kept within 15 of nacelle azimuth positions with respect to upwind, and to measure the position of the anemometer. Wind direction was also averaged over a 1 minute period. Air temperature and pressure were measured and recorded according to the requirements of IEC For purposes of development of this Test Report, temperature and pressure was also averaged over a 1 minute period. 7.3 Data reduction procedures Wind speed The wind speeds measured at the anemometer on the meteorological mast were corrected to wind speeds at reference conditions, V s, using Equation 2 below: Where: Equation 2 z 0ref is the reference roughness length of 0.05 m; z 0 is the roughness length; H is the rotor centre height; z ref is the reference height, 10 m; z is the anemometer height. Equation 3 uses the following principles: The correction for the measured height to the rotor centre height uses a logarithmic wind profile with the site roughness length z 0 to account for the actual site conditions. The correction from rotor centre height to reference conditions uses a logarithmic wind profile with a reference roughness length z 0ref. This describes the noise characteristic independent of the terrain. The roughness length z 0 was estimated according to Table 1 of the IEC standard. A roughness length 0.05 m was used for the Intertek RTC. Page 12 of 35

13 7.3.2 Correction for background noise All measured sound pressure levels were corrected for the influence of background noise. For average background sound pressure levels that are 6 db or more below the combined level of wind turbine and background noise, the corrected value was obtained using Equation 3 below: Where: L s L s+n L n Equation 3 is the equivalent continuous sound pressure level, in db, of the wind turbine operating alone; is the equivalent continuous sound pressure level, in db, of the wind turbine plus background noise; is the background equivalent continuous sound pressure level, in db. Where the equivalent continuous sound pressure level of the wind turbine plus background noise was less than 6 db but more than 3 db higher than the background level, the correction is by subtraction of 1.3 db and marked with an asterisk, *. These data points are not used for the determination of apparent sound power level. If the difference is less than 3 db, no data points are reported, but it will be reported that the wind turbine noise level was less than the background noise level Apparent sound power level and one-third octave band Apparent sound power level is determined by 4 th order regression, as required by the Standard, and is based upon the noise emissions from the wind turbine at the integer wind speeds 6, 7, 8, 9 and 10 m/s. A 4 th order regression is used when the correlation coefficient is 0.8 or greater. Turbine noise emissions were measured at the reference position by a series of at least 30 measurements concurrent with measurements of the wind speed. Background noise emissions were measured immediately before or after turbine noise in similar environmental conditions, and also for a period of at least 30 minutes. Data was integrated over a period of1 minute. At least three measurements of both turbine noise and background noise were required to be within ±0.5 m/s of each integer wind speed. The regression is performed on both turbine noise and background noise separately. Once equivalent continuous sound pressure levels of turbine noise and background noise are determined at the integer wind speeds, they are corrected as described in Section above. The apparent sound power level, L WA,k, at the integer wind speeds is calculated using Equation 4 below and from the background corrected sound pressure level, L Aeq,c,k, as defined as L s in Equation 3 above: Where: Equation 4 L Aeq,c,k is the background corrected A-weighted sound pressure level at the integer wind speeds and under reference conditions; R 1 is the slant distance in meters from the rotor centre to the microphone; S 0 is a reference area, S0 = 1 m 2. The 6 db constant in Equation 4 accounts for the approximate pressure doubling that occurs for the sound level measurements on a ground board. One-third octave band levels of the wind turbine noise are also corrected for the corresponding one-third octave band levels of background noise according to the procedure detailed above. Page 13 of 35

14 7.3.4 Tonality General methodology Narrowband analysis is used to determine the presence of tones in the noise at the same wind speeds as the sound power level measurement. For each wind speed bin, the two one-minute periods closest to the integer wind speed value are analyzed for the presence of tones. The two one-minute measurements are divided into 12 ten-second periods, from which 12 energy averaged narrowband spectra using the Hanning window are obtained. For each of the 12 ten-second periods in each of the integer wind speeds; The sound pressure level L pt,j,k of any tones present are determined. The sound pressure level of masking noise L pn,j,k in a critical band around the tone are determined. The tonality L tn,j,k, the difference between the sound pressure level of the tone and the masking noise level, is determined. Overall tonality, L k, is determined as the energy average of the 12 individual L tn,j,k. Refer to Equation 5 below to calculate the bandwidth of a critical band around a tone. In Equation 5, f c is the centre frequency in Hz Identifying possible tones The following procedure is used to identify possible tones: Equation 5 1. Find local maxima in the spectrum. 2. Calculate the average energy in the critical band centered on each local maximum, not including the line of the local maximum and the two adjacent lines. 3. If the local maximum is more than 6 db above the average masking noise level, then it is a possible tone Classification of spectral lines within the critical band The critical band is positioned with centre frequency coincident with the possible tone frequency. Within each critical band, every spectral line is classified as tone, masking, or neither, using the following procedure. 1. Calculate the L 70% sound pressure level, where L 70% is the energy average of the 70% of spectral lines in the critical band with the lowest levels. 2. Define a criterion level equal to the L 70% level plus 6 db; a. A spectral line is classified as masking if its level is less than the criterion level. L pn,avg is the energy average of all spectral lines classified as masking. b. A spectral line is classified as tone if its level exceeds L pn,avg plus 6 db. c. Where several adjacent lines are classified as tone, the line having the greatest level is identified. Adjacent lines are only classified as a tone if their levels are within 10 db of the highest level. d. A spectral line is classified as neither if it cannot be classified as either tone or masking as described above. Spectral lines identified as neither are ignored in further analysis. Figures 8 through 11 in IEC are illustrations of the items defined in this section. Page 14 of 35

15 Determination of the tone level and correction for background noise The sound pressure level of the tone, L pt,j,k is determined by energy summing all spectral lines identified as tones within the critical band as defined in of this Test Report. For comparison with the corresponding analysis of the wind turbine noise, it must be ensured that any identified tones do not originate from the background noise. In order to determine this, a 2-minute narrowband spectrum of the background noise is determined using the two 1-minute measurements closest to the integer wind speed. The background corrected energy average of the spectral lines identified as masking within the critical band, L pn,avg,j,k, is determined following the same procedure identified within Section of this Test Report. Background levels in the same critical band and integer wind speed as used during tonal analysis are used for comparison. The background noise level is calculated from the energy sum of all lines in the critical band. The background noise level must be at least 6 db lower than the wind turbine noise in the relevant critical bands Determination of the masking noise level The masking noise level, L pn,j,k, is defined in Equation 5 below. In Equation 5, the effective noise bandwidth is 1.5 times the frequency resolution, which includes a correction for the use of the Hanning window Determination of tonality and audibility Equation 5 The difference between the tone level, L pt,j,k and the level of the masking noise in the corresponding critical band is given in Equation 6 below: Equation 6 If no tone was identified according to for some of the 12 ten-second spectra so that L tn,j,k is undefined, it is be replaced by the value defined in Equation 7 below: Equation 7 The 12 L tn,j,k are energy averaged to one L k, k = 6, 7, 8, 9, 10 for each wind speed bin. Tones in different spectra with frequencies within 10% of the critical bandwidth are understood to be the same tone. If this occurs, the average frequency is used to determine the tonal audibility. For each value of L k, a frequency dependent correction is applied to compensate for the response of the human ear to tones of different frequency. The tonal audibility, La, k, is given in Equation 8 below: Equation 8 In Equation 8, L a is the frequency dependent audibility criterion, which is defined in Equation 9. In Equation 9, f is the frequency of the tone, in Hz. Page 15 of 35

16 Equation 9 A corresponding value of L a,k is calculated for each value of L k. Where tonal audibility is greater than or equal to -3.0 db, the values of L a,k are reported. If the tonal audibility is less than -3.0 db the tones are not reported. 8.0 Test Results 8.1 Database A total of 91 one-minute data points were included in the database; 52 of which were turbine noise data points. Table 3 below shows the total number of measurements at each integer wind speed that were included in the database. Turbine + Background Background Only V s Data points V s Data points Table 3 Measurement database Plots of wind speed, wind direction, temperature, and pressure during the measurement periods are shown in Figures 7, 8, 9, and 10 below. Page 16 of 35

17 Figure 7 Standardized wind speed during the measurement periods Figure 8 Wind direction during the measurement periods Page 17 of 35

18 Figure 9 Air temperature during the measurement periods Figure 10 Air pressure during the measurement periods Page 18 of 35

19 8.2 Apparent sound power level Uncertainty Type A and Type B uncertainties are expressed in the form of standard deviations and are combined by the method of combination of variances to form the combined standard uncertainty. The combined standard uncertainty is found as the root sum of the squared components: U A, U B1, U B2, U B3, U B4, U B5, U B6, U B7, U B8, and U B9. Type B, U B, uncertainty is determined by using the typical values provided in Table D.1 in IEC , Annex D. The standard typical values were used for U B2 through U B9. The value for U B1 was derived from the calibration data sheet uncertainties. Table 4 below shows the Type B uncertainties used in the determination of results within this Test Report. Item Description Type B Value Type Source U B1 Calibration 0.54 Actual Calibration U B2 Measurement Chain 0.20 Typical IEC U B3 Board 0.30 Typical IEC U B4 Distance 0.10 Typical IEC U B5 Impedance 0.10 Typical IEC U B6 Turbulence 0.40 Typical IEC U B7 Wind Speed Measured 0.90 Typical IEC U B8 Direction 0.30 Typical IEC U B9 Background 0.10 Typical IEC Table 4 Type B Uncertainties Type A uncertainty, U A is evaluated by using statistical methods to a series of repeated determinations. U A, the parameter describing the type A uncertainty is the standard error of the estimated L Aeq,c,k at each integer wind speed. L Aeq,c,k is the equivalent continuous A-weighted sound pressure level corrected for background noise at each integer wind speed and corrected to reference conditions, where k = 6, 7, 8, 9, and 10. Table 5 below shows the continuous A-weighted sound pressure levels and the type A uncertainties at integer wind speeds. Wind Speed L Aeq,c,k Type A Uncertainty m/s db(a) db(a) Table 5 Continuous A-weighted sound pressure levels and type A uncertainty at integer wind speeds Page 19 of 35

20 Table 6 below shows the apparent sound power levels and combined uncertainty, U c, at integer wind speeds. Wind Speed L WA,k Combined Uncertainty m/s db(a) db(a) Table 6 Apparent sound power levels and combined uncertainty at integer wind speeds Apparent sound power level results The apparent sound power level (L WA,k ) at integer wind speeds was derived following the procedure outlined in section of this report, with the deviation mentioned in section 4.0 of this report. Using the 4 th order regression for turbine noise, and the linear regression for background noise, the apparent sound power level was determined. Figure 11 below shows the measured data pairs of sound pressure levels recorded at various standardized wind speeds and the fitted regressions. Figure second averaged A-weighted sound pressure levels as a function of standardized wind speed Page 20 of 35

21 A linear regression was used for background noise due to the higher correlation coefficient of the linear regression versus a 4 th order regression. The poor correlation for the 4 th order regression is likely due to the two background noise data points that appear to be outliers in Figure 11 above. After further investigating these data points there was no intruding intermittent noise or other reason to support their exclusion from the database; therefore, they remain in the database and the linear regression was chosen. Figure 12 below shows the combined uncertainty at apparent sound power levels at integer wind speeds. The uncertainty is shown using error bars in the y-direction. Figure 12 Combined uncertainty at apparent sound power levels at integer wind speeds Page 21 of 35

22 8.3 One-third octave band spectra Uncertainty For the one-third octave band spectra a similar approach as described in section above is followed, but with the modifications as described in IEC , Annex D. For category A uncertainty the U A for each band is the standard error on the averaged band level, computed as the standard deviation divided by, where N is the number of measured spectra. For category B uncertainty the U B3 value is considered to be much larger than for apparent sound power levels, and is estimated in IEC , Annex D as a typical value of 1.7 db. The other category B values remain the same, as described in Table 7 in section of this Test Report. The combined uncertainty, U c, is again the root sum square of the category A and category B values One-third octave results The A-weighted third octave spectra at integer wind speeds were derived following the procedure outlined in Section of this Test Report. Figures 13 and 14 below show the background corrected third octave spectra over the range of 6 to 10 m/s. For areas in Figures 13 and 14 where no data is shown, this represents turbine continuous sound pressure levels that were less than the background continuous sound pressure levels. Figure 13 Third octave spectra at the 6 m/s, 7 m/s, and 8 m/s integer wind speeds Page 22 of 35

23 Figure 14 Third octave spectra at the 9 m/s and 10 m/s integer wind speeds Page 23 of 35

24 Table 7 below represents the correction to all measured sound pressure levels for the influence of background noise on the turbine. The data marked with an asterisk, *, indicates corrected data when the continuous sound pressure level of the wind turbine plus the background noise is less than 6 db but more than 3 db higher than the background level. Where data is missing, the turbine continuous sound pressure levels were less than the background continuous sound pressure levels. 6 m/s 7 m/s 8 m/s 9 m/s 10 m/s Frequency Ls Uc Ls Uc Ls Uc Ls Uc Ls Uc Hz db(a) db(a) db(a) db(a) db(a) db(a) db(a) db(a) db(a) db(a) 50 * * * * * * * * * * * * * * * * * * * * Table 7 Background corrected one-third octave spectra and combined uncertainty at integer wind speeds Page 24 of 35

25 8.4 Tonality Uncertainty For tonality a similar approach, as described in section and above, is followed. The modifications as described in IEC , Annex D are followed. For category A uncertainty, U A for each tone is the standard error on the averaged tone level. For category B uncertainty, U B3 can be estimated to be 1.7 db. As the reported value L tn is a difference, and as the wind speed is expected to be of secondary importance, the values of U B1, U B4, and U B6 can be estimated to be smaller than for L WA, see Table D.1 in the IEC standard. For the results determined in this test report, the values of U B1, U B4, and U B6 are identical to those shown in Table 6 within this report Tonality results The presence of tones at integer wind speeds were derived following the procedure outlined in Section of this Test Report. The analysis only yielded one reportable tone at the 7 m/s integer wind speed. The results are shown in Table 8 below. The parameter K below represents the integer wind speed. L k represents the difference between the tone level and the level of the masking noise in the critical band around the tone at the integer wind speeds. L tnj,k represents the tonality of the j th spectra at k th wind speed. L a, k represents the difference between the tonality and the audibility criterion at integer wind speeds. U A represents the category A uncertainty, U B represents the category B uncertainty, and U C represents the combined uncertainty. k [m/s] 7 Freq [Hz] 216 L tn1,k 0.82 L tn2,k 3.67 L tn3,k 2.22 L tn4,k 0.58 L tn5,k 0.85 L tn6,k 0.25 L tn7,k 1.12 L tn8,k 0.04 L tn9,k 0.04 L tn10,k 1.57 L tn11,k 0.04 L tn12,k 0.04 L k db(a) L a, k db(a) 1.77 U A db(a) 1.76 U B db(a) 2.03 U C db(a) 2.69 Table 8 Tonality results at the 7 m/s integer wind speed Page 25 of 35

26 Figure 15 below graphically shows the reportable tone at the 7 m/s integer wind speed with classification of spectral lines (masking, neither, or tone). Figure 15 Ten second spectrum showing the reportable tone at the 7 m/s integer wind speed Page 26 of 35

27 Appendix The following sections can be found within this Appendix: A Test Equipment B Wiring Diagrams C Photographs D Calibration Certificates for Acoustical Equipment Page 27 of 35

28 A Test Equipment A.1 Calibrated equipment Measurement Manufacturer Model Serial Cal Date Cal Due Power Transducer * Ohio Semitronics DMT- 1040EY /19/2011 4/19/2012 Current Transformer* Ohio Semitronics (200:5A) /19/2011 4/19/2012 Wind Speed 1** Adolf Thies GmbH /3/2010 5/3/2011 Wind Speed 2 Adolf Thies GmbH /3/2010 5/3/2011 Wind Direction Adolf Thies GmbH /4/2010 5/4/2011 Temperature / Humidity Adolf Thies GmbH /15/2010 4/15/2011 Barometric Pressure Vaisala PTB330 F /8/2010 4/8/2011 Microphone*** BSWA Technology MP /9/2010 9/9/2011 Preamplifier BSWA Technology MA /9/2010 9/9/2011 DAQ Module National Instruments USB A3AF 9/9/2010 9/9/2011 Acoustical Calibrator BSWA Technology CA /24/2010 8/24/2011 *PT/CT calibrated as a system **All sensors on the meteorological tower were sent out near their calibration due dates and replaced with newly calibrated instruments. Records of the new instruments, and verification of the original instruments maintaining calibration throughout the test period, are maintained within the Intertek project file. ***BSWA equipment, NI module, and acoustic laptop calibrated both as a system and individually. Note: All instruments were replaced with newly calibrated instruments post their calibration due dates. A.2 Non-calibrated equipment Description Manufacturer Model Comments Windscreen Scantek Inc. WS1-80T Data Acquisition Backplane National Instruments 9178 Compact DAQ Data Acquisition Module National Instruments NI 9203 A.3 Software Digital I/O signal verified with LabVIEW Digital I/O signal verified with LabVIEW Description Manufacturer Model Comments Acoustic Data Recording And Analysis Software Delta NoiseLab Pro Verified software Excel Analysis Microsoft 2003 Verified software Page 28 of 35

29 B Wiring Diagrams B.1 Typical wiring diagram for the Fortis Montana Page 29 of 35

30 B.2 Location of Intertek power measurement Page 30 of 35

31 Fortis Wind Energy BV C Photographs C.1 April Microphone and sound board Page 31 of 35

32 C.2 February Met tower, field board, and turbine tower looking toward point of acoustic measurement Page 32 of 35

33 D Calibration Certificates for Acoustical Equipment D.1 Microphone and preamplifier Page 33 of 35

34 D.2 Sound level meter Page 34 of 35

35 D.3 Acoustical calibrator Page 35 of 35

Document No 10/6298/001/GLA/O/R/001 Issue : B2. Kingspan Renewables Ltd. Kingspan KW6 Wind Turbine Noise Performance Test

Document No 10/6298/001/GLA/O/R/001 Issue : B2. Kingspan Renewables Ltd. Kingspan KW6 Wind Turbine Noise Performance Test Document No 10/6298/001/GLA/O/R/001 Issue : B2 Kingspan Renewables Ltd Kingspan KW6 Wind Turbine Noise Performance Test December 11 2 Bath Street, Glasgow, G2 4GZ Telephone: +44 (0) 141 227 1700 www.sgurrenergy.com

More information

Wind Turbine Generator System Acoustic Noise Test Report. Whisper H40 Wind Turbine

Wind Turbine Generator System Acoustic Noise Test Report. Whisper H40 Wind Turbine June 2003 NREL/EL-500-34383 Wind Turbine Generator System Acoustic Noise Test Report for the Whisper H40 Wind Turbine By National Wind Technology Center National Renewable Energy Laboratory 1617 Cole Boulevard

More information

Appendix 4A Candidate Turbine Manufacturer Data

Appendix 4A Candidate Turbine Manufacturer Data Appendix 4A Candidate Turbine Manufacturer Data Stornoway Wind Farm Environmental Statement (March 2015) Noise 4-19 Standard Acoustic Emission, SWT-3.2-101, Rev. 0 Document ID: E W TE-40-0000-0000-00 SD

More information

POWER QUALITY MEASUREMENT PROCEDURE. Version 4 October Power-Quality-Oct-2009-Version-4.doc Page 1 / 12

POWER QUALITY MEASUREMENT PROCEDURE. Version 4 October Power-Quality-Oct-2009-Version-4.doc Page 1 / 12 POWER QUALITY MEASUREMENT PROCEDURE Version 4 October 2009 Power-Quality-Oct-2009-Version-4.doc Page 1 / 12 MEASNET 2009 Copyright all rights reserved This publication may not be reproduced or utilized

More information

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT SCOPE OF WORK ASTM C423 SOUND ABSORPTION TESTING ON TEMPE, ROLLER SHADE FABRIC REPORT NUMBER I7375.01-113-11-R0 TEST DATE 08/14/18 ISSUE DATE 09/04/18

More information

Commercial Documentation Wind Turbine Generator Systems Hz and 60 Hz

Commercial Documentation Wind Turbine Generator Systems Hz and 60 Hz GE Energy Commercial Documentation Wind Turbine Generator Systems 2.75-103 - 50 Hz and 60 Hz Product Acoustic Specifications Normal Operation according to IEC 61400-11 imagination at work 2010 GE Company.

More information

1 Wind Turbine Acoustics. Wind turbines generate sound by both mechanical and aerodynamic

1 Wind Turbine Acoustics. Wind turbines generate sound by both mechanical and aerodynamic Wind Turbine Acoustics 1 1 Wind Turbine Acoustics Wind turbines generate sound by both mechanical and aerodynamic sources. Sound remains an important criterion used in the siting of wind farms. Sound emission

More information

Wind Resource Data Summary Cotal Area, Guam Data Summary and Transmittal for December 2011

Wind Resource Data Summary Cotal Area, Guam Data Summary and Transmittal for December 2011 Wind Resource Data Summary Cotal Area, Guam Data Summary and Transmittal for December 2011 Prepared for: GHD Inc. 194 Hernan Cortez Avenue 2nd Floor, Ste. 203 Hagatna, Guam 96910 January 2012 DNV Renewables

More information

Estimated Sound Power Level of the ENERCON E-92 Operational Mode I (Data Sheet)

Estimated Sound Power Level of the ENERCON E-92 Operational Mode I (Data Sheet) Estimated Sound Power Level E-92 Page 1 of 3 Estimated Sound Power Level of the ENERCON E-92 Operational Mode I (Data Sheet) Imprint Editor: ENERCON GmbH Dreekamp 5 26605 Aurich Germany Telephone: 04941-927-0

More information

Review of Anemometer Calibration Standards

Review of Anemometer Calibration Standards Review of Anemometer Calibration Standards Rachael V. Coquilla rvcoquilla@otechwind.com Otech Engineering, Inc., Davis, CA Anemometer calibration defines a relationship between the measured signals from

More information

Sound Absorption Test Intertek. kraft paper softwall + softblock modular system. m o l o d e s i g n, l t d

Sound Absorption Test Intertek. kraft paper softwall + softblock modular system. m o l o d e s i g n, l t d Sound Absorption Test Intertek kraft paper softwall + softblock modular system m o l o d e s i g n, l t d 1470 Venables Street V a n c o u v e r, B. C. C a n a d a V 5 L 2 G 7 t +1 604 696 2501 f +1 604

More information

The information included in the following report presents the results of sound pressure and sound power testing.

The information included in the following report presents the results of sound pressure and sound power testing. ISO 7779:2010 Acoustics -- Measurement of airborne noise emitted by information technology and telecommunications equipment 1 of 14 DEVICES - solid panel case - window panel case Report Date: 06/25/2015

More information

IECRE OPERATIONAL DOCUMENT

IECRE OPERATIONAL DOCUMENT IECRE OD-551-12 IECRE OPERATIONAL DOCUMENT Edition 2.0 2018-08-10 IEC System for Certification to Standards relating to Equipment for use in Renewable Energy applications (IECRE System) Assessment of RETLs

More information

Welcome to the world of wind energy. Wind Potential. Dr. D. V. Kanellopoulos OPWP Renewable Energy Training Program December 2016 Muscat, Oman

Welcome to the world of wind energy. Wind Potential. Dr. D. V. Kanellopoulos OPWP Renewable Energy Training Program December 2016 Muscat, Oman Welcome to the world of wind energy Wind Potential Dr. D. V. Kanellopoulos OPWP Renewable Energy Training Program 11-14 December 2016 Muscat, Oman 1 Solar radiation powers up the wind 2 Surface air temperatures

More information

Standard Practices for Air Speed Calibration Testing

Standard Practices for Air Speed Calibration Testing Standard Practices for Air Speed Calibration Testing Rachael V. Coquilla Bryza Wind Lab, Fairfield, California Air speed calibration is a test process where the output from a wind measuring instrument

More information

Puhuri Oy Wind Farm Kopsa Uleåborg, Finland

Puhuri Oy Wind Farm Kopsa Uleåborg, Finland REPORT A 1 (19) Please refer to Jens Fredriksson Phone +46 10 505 60 97 jens.fredriksson@afconsult.com Date 2014-10-31 Order no 593481 Puhuri Oy Wind Farm Kopsa Uleåborg, Finland Sound immission measurement

More information

Centralized Forecasting Registration and Communication Requirements for Distribution Connected Variable Generators. IESO Training

Centralized Forecasting Registration and Communication Requirements for Distribution Connected Variable Generators. IESO Training Centralized Forecasting Registration and Communication Requirements for Distribution Connected Variable Generators IESO Training May 2017 Centralized Forecasting - Registration and Communication Requirements

More information

Uncertainties associated with the use of a sound level meter

Uncertainties associated with the use of a sound level meter NPL REPORT DQL-AC 002 Uncertainties associated with the use of a sound level meter Richard Payne April 2004 April 2004 ABSTRACT Uncertainties associated with the use of a sound level meter Richard Payne

More information

Identification of Variables for Site Calibration and Power Curve Assessment in Complex Terrain. SiteParIden

Identification of Variables for Site Calibration and Power Curve Assessment in Complex Terrain. SiteParIden October 2001 ECN-C--01-102 Identification of Variables for Site Calibration and Power Curve Assessment in Complex Terrain SiteParIden JOR3-CT98-0257 Relative Power Curve Measurements in Complex Terrain

More information

Sound Power Level. of the ENERCON E-82 E2. Operational Mode I. (Data Sheet)

Sound Power Level. of the ENERCON E-82 E2. Operational Mode I. (Data Sheet) 1 of 3 Sound Power Level of the ENERCON E-82 E2 Operational Mode I (Data Sheet) Imprint Editor: Telephone: 04941-927-0 Fax: 04941-927-109 Copyright: Updates: Revision Revision: 1.0 Department: ENERCON

More information

Site Description: Tower Site

Site Description: Tower Site Resource Summary for Fort Collins Site Final Report Colorado Anemometer Loan Program Monitoring Period: /0/00 11/03/007 Report Date: January 1, 00 Site Description: The site is located adjacent to the

More information

Site Description: Tower Site

Site Description: Tower Site Resource Summary for Elizabeth Site Final Report Colorado Anemometer Loan Program Monitoring Period: 7/3/06 /26/07 Report Date: January, 0 Site Description: The site is.6 miles northeast of the town of

More information

Erik Sloth Vestas. Niels Christian Møller Nielsen VESTAS Ejler Kristensen BONUS Energy Bo Søndergaard DELTA

Erik Sloth Vestas. Niels Christian Møller Nielsen VESTAS Ejler Kristensen BONUS Energy Bo Søndergaard DELTA Problems related to the use of the existing noise measurement standards when predicting noise from wind turbines and wind farms. Erik Sloth Vestas Niels Christian Møller Nielsen VESTAS Ejler Kristensen

More information

Method of Measuring Machinery Sound Within an Equipment Space

Method of Measuring Machinery Sound Within an Equipment Space ANSI/AHRI Standard 575 (Formerly ARI Standard 575) 2008 Standard for Method of Measuring Machinery Sound Within an Equipment Space Price $15.00 (M) $30.00 (NM) Printed in U.S.A. 8Copyright 1994, by Air-Conditioning

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer LDSR 0.3-TP/SP1 I P R N = 300 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed

More information

Measured wind turbine loads and their dependence on inflow parameters

Measured wind turbine loads and their dependence on inflow parameters Measured wind turbine loads and their dependence on inflow parameters L. Manuel & L. D. Nelson Dept. of Civil Engineering, University of Texas at Austin, TX, USA H. J. Sutherland & P. S. Veers Sandia National

More information

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562 REPORT NUMBER: 102550917MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA TEST REPORT EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562 RENDERED TO Cali Bamboo 6675 Mesa Ridge

More information

Sound Engineering Test and Analysis

Sound Engineering Test and Analysis Sound Engineering Test and Analysis Product sound and sound quality are key aspects of product perception. How a product sounds plays a critical role in conveying the right message about its functionality,

More information

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method INTERNATIONAL STANDARD ISO 10494 Second edition 2018-04 Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method Turbines et groupes de turbines Mesurage du bruit aérien

More information

MAC Aura XB Acoustic Test Report

MAC Aura XB Acoustic Test Report MAC Aura XB Acoustic Test Report 2017. Information subject to change without notice. HARMAN Professional and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss,

More information

WIND DATA REPORT. Vinalhaven

WIND DATA REPORT. Vinalhaven WIND DATA REPORT Vinalhaven July 1, 2004 September 30, 2004 Prepared for Fox Islands Electric Cooperative By Melissa L. Ray Anthony L. Rogers April 4, 2005 Renewable Energy Research Laboratory 160 Governors

More information

WIND DATA REPORT. Vinalhaven

WIND DATA REPORT. Vinalhaven WIND DATA REPORT Vinalhaven April 1, 2004 June 30, 2004 Prepared for Fox Islands Electric Cooperative By Melissa L. Ray Anthony L. Rogers April 4, 2005 Renewable Energy Research Laboratory 160 Governors

More information

Technical Requirements. Version No. 1.0 Effective Date 10/1/2008

Technical Requirements. Version No. 1.0 Effective Date 10/1/2008 PURPOSE This document applies to wind Generators and describes technical standards that such wind Generators must satisfy to be qualified as a Participating Intermittent Resource (PIR) under the CAISO

More information

In Association With. Introduces. TPT Contractor

In Association With. Introduces. TPT Contractor In Association With Introduces TPT Contractor Software for Contractors with TENSIONMETERS Table of Contents Capabilities 4 Setup and Use 7 The Dashboard 12 Tower Setup Form 18 Field Calibration Verification

More information

Standard ECMA-108 3rd Edition - December Measurement of High-frequency Noise emitted by Information Technology and Telecommunications Equipment

Standard ECMA-108 3rd Edition - December Measurement of High-frequency Noise emitted by Information Technology and Telecommunications Equipment Standard ECMA-108 3rd Edition - December 1996 Standardizing Information and Communication Systems Measurement of High-frequency Noise emitted by Information Technology and Telecommunications Equipment

More information

TEST REPORT IEC Photobiological safety of lamps and lamp systems

TEST REPORT IEC Photobiological safety of lamps and lamp systems age 1 of 20 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. TEST REORT hotobiological safety of lamps and lamp systems Report Reference No.... : 140729054GZU-002

More information

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT SCOPE OF WORK DR65 FIXED REPORT NUMBER H3108.01-301-46 R0 TEST DATE 11/09/17 ISSUE DATE 11/14/17 RECORD RETENTION END DATE 11/09/22 PAGES

More information

Non-Acoustical Inputs

Non-Acoustical Inputs CHAPTER 18 Non-Acoustical Inputs This chapter discusses the use of external transducers and devices to provide non-acoustical data to the Model 831. Included are the following: 831-INT 831-INT Interface

More information

Expedited Filing Draft August 22, 2017

Expedited Filing Draft August 22, 2017 Applicability 1 Section 304.9 applies to: (a) (b) Requirements Expedited Filing Draft August 22, 2017 the legal owner of a wind or solar aggregated generating facility connected to the interconnected electric

More information

Intertek Environmental VOC Emissions

Intertek Environmental VOC Emissions 4700 Broadmoor SE, Suite 200 Kentwood, MI 49512 Jesse.ondersma@intertek.com Telephone: 616-656-7401 Facsimile: 616-656-2022 www.intertek.com ELIZABETH FATIMA DO NASCIMENTO AIME P.O.: N.A. Page 1 of 8 Intertek

More information

Order No. G Date: September 8, 2010 REPORT NO CRT-001 TEST OF SMF/PAPI SYSTEM RENDERED TO

Order No. G Date: September 8, 2010 REPORT NO CRT-001 TEST OF SMF/PAPI SYSTEM RENDERED TO REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Order No. G100147381 Date: September 8, 2010 INTRODUCTION REPORT NO. 100147381CRT-001 TEST OF SMF/PAPI SYSTEM RENDERED TO ARGOS INGEGNERIA SpA VIA TIBURTINA,

More information

ASTM C STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS

ASTM C STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS Page 1 of 10 ASTM C 518 04 STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLO METER APPARATUS Rockwool Premium Plus Insulation Project No. 3194876SAT-001A

More information

Appendix 1. Supplementary information on methodology and chorus projections Location matters: evaluating Greater Prairie-Chicken (Tympanuchus cupido)

Appendix 1. Supplementary information on methodology and chorus projections Location matters: evaluating Greater Prairie-Chicken (Tympanuchus cupido) Appendix 1. Supplementary information on methodology and chorus projections Location matters: evaluating Greater Prairie-Chicken (Tympanuchus cupido) boom chorus propagation Supplemental Methods Study

More information

ISO 6395 INTERNATIONAL STANDARD. Earth-moving machinery Determination of sound power level Dynamic test conditions

ISO 6395 INTERNATIONAL STANDARD. Earth-moving machinery Determination of sound power level Dynamic test conditions INTERNATIONAL STANDARD ISO 6395 Second edition 2008-03-15 Earth-moving machinery Determination of sound power level Dynamic test conditions Engins de terrassement Détermination du niveau de puissance acoustique

More information

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Project No. G100896445 Date: September 26, 2012 REPORT NO. 100896445CRT-001 TEST OF ONE LED

More information

MOLEKULE INC. TEST REPORT

MOLEKULE INC. TEST REPORT MOLEKULE INC. TEST REPORT SCOPE OF WORK VOC Emissions on Part C Test 1 REPORT NUMBER 103658037GRR-002 ISSUE DATE 18-October-2018 PAGES 8 DOCUMENT CONTROL NUMBER Per GFT-OP-10 (6-March-2017) 2018 INTERTEK

More information

TEST REPORT. Page 1 of 11

TEST REPORT. Page 1 of 11 Applicant: Radomir Klabal Komenskeho 446, Bilovice nad Svitavou, Czech Republic Sample Description Product : Compact Fluorescent Lamp Model No. : CFL15T2S27E27 Brand Name : Divetta Electrical Rating :

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 11201 Second edition 2010-05-15 Acoustics Noise emitted by machinery and equipment Determination of emission sound pressure levels at a work station and at other specified positions

More information

Deviations between wind speed data measured with nacelle-mounted anemometers on small wind turbines and anemometers mounted on measuring masts

Deviations between wind speed data measured with nacelle-mounted anemometers on small wind turbines and anemometers mounted on measuring masts Agronomy Research 12(2), 433 444, 2014 Deviations between wind speed data measured with nacelle-mounted anemometers on small wind turbines and anemometers mounted on measuring masts A. Allik*, J. Uiga

More information

TEST REPORT. Test Method : See the attached sheets.

TEST REPORT. Test Method : See the attached sheets. Applicant: Radomir Klabal Komenskeho 446, Bilovice nad Svitavou, Czech Republic Sample Description Product : Compact Fluorescent Lamp Model No. : CFL20T2S27E27 Brand Name : Divetta Electrical Rating :

More information

WIND DATA REPORT FOR THE YAKUTAT JULY 2004 APRIL 2005

WIND DATA REPORT FOR THE YAKUTAT JULY 2004 APRIL 2005 WIND DATA REPORT FOR THE YAKUTAT JULY 2004 APRIL 2005 Prepared on July 12, 2005 For Bob Lynette 212 Jamestown Beach Lane Sequim WA 98382 By John Wade Wind Consultant LLC 2575 NE 32 nd Ave Portland OR 97212

More information

WIND DATA REPORT. Lynn, MA

WIND DATA REPORT. Lynn, MA WIND DATA REPORT Lynn, MA September 2005 Prepared for Massachusetts Technology Collaborative 75 North Drive Westborough, MA 01581 by Kai Wu James F. Manwell Anthony L. Rogers Anthony F. Ellis February

More information

Applications. Remote Weather Station with Telephone Communications. Tripod Tower Weather Station with 4-20 ma Outputs

Applications. Remote Weather Station with Telephone Communications. Tripod Tower Weather Station with 4-20 ma Outputs Tripod Tower Weather Station with 4-20 ma Outputs Remote Weather Station with Telephone Communications NEMA-4X Enclosure with Two Translator Boards and Analog Barometer Typical Analog Output Evaporation

More information

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard 92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1

More information

WEATHER STATION FOR SOLAR FARM MONITORING

WEATHER STATION FOR SOLAR FARM MONITORING WEATHER STATION FOR SOLAR FARM MONITORING SOLAR FARM MONITORING SYSTEM: Measures global, horizontal, & background irradiance. Measures wind speed, wind direction, ambient temperature, and relative humidity.

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP series I P N = 4, 6, 12, 15 A Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary

More information

PRELIMINARY WIND RESOURCE ASSESSMENT OF WINDYGATES FIRST NATIONS PROJECT. Department of Innovation, Energy and Mines Contact. Rick Halas Document No

PRELIMINARY WIND RESOURCE ASSESSMENT OF WINDYGATES FIRST NATIONS PROJECT. Department of Innovation, Energy and Mines Contact. Rick Halas Document No PRELIMINARY WIND RESOURCE ASSESSMENT OF WINDYGATES FIRST NATIONS PROJECT Client Department of Innovation, Energy and Mines Contact Rick Halas Document No Issue B Status Classification Client s Discretion

More information

Comparison of Noise Test Codes when Applied to air Compressors

Comparison of Noise Test Codes when Applied to air Compressors VDI-Berichte Nr. 1932, 2006 A 6 83 Comparison of Noise Test Codes when Applied to air Compressors Michael J. Lucas, INCE Bd. Cert., Ingersoll-Rand Company, Davidson/NC INTRODUCTION Beginning January 2004,

More information

Sonic Anemometer Classification

Sonic Anemometer Classification Summary report VT121243 - Version 1.1 Sonic Anemometer Classification According to (2017-03) Classification Scheme Description of Anemometer Manufacturer: Adolf Thies GmbH & Co. KG Hauptstrasse 76 37083

More information

Increasing Transmission Capacities with Dynamic Monitoring Systems

Increasing Transmission Capacities with Dynamic Monitoring Systems INL/MIS-11-22167 Increasing Transmission Capacities with Dynamic Monitoring Systems Kurt S. Myers Jake P. Gentle www.inl.gov March 22, 2012 Concurrent Cooling Background Project supported with funding

More information

Wind Tower Deployments and Pressure Sensor Installation on Coastal Houses Preliminary Data Summary _ Sea Grant Project No.

Wind Tower Deployments and Pressure Sensor Installation on Coastal Houses Preliminary Data Summary _ Sea Grant Project No. Wind Tower Deployments and Pressure Sensor Installation on Coastal Houses Preliminary Data Summary _ Sea Grant Project No.:1020040317 Submitted to: South Carolina Sea Grant Consortium 287 Meeting Street

More information

Statistical Analysis of Wind Turbine Inflow and Structural Response Data From the LIST Program

Statistical Analysis of Wind Turbine Inflow and Structural Response Data From the LIST Program Luke D. Nelson Lance Manuel Department of Civil Engineering, University of Texas at Austin, Austin, TX 78712 Herbert J. Sutherland Paul S. Veers Wind Energy Technology Department, Sandia National Laboratories,

More information

Near-Field Sturgeon Monitoring for the New NY Bridge at Tappan Zee. Quarterly Report October 1 December 31, 2014

Near-Field Sturgeon Monitoring for the New NY Bridge at Tappan Zee. Quarterly Report October 1 December 31, 2014 Near-Field Sturgeon Monitoring for the New NY Bridge at Tappan Zee Quarterly Report October 1 December 31, 2014 Prepared by AKRF, Inc. 7250 Parkway Drive, Suite 210 Hanover, MD 21076 for New York State

More information

7 th International Conference on Wind Turbine Noise Rotterdam 2 nd to 5 th May 2017

7 th International Conference on Wind Turbine Noise Rotterdam 2 nd to 5 th May 2017 7 th International Conference on Wind Turbine Noise Rotterdam 2 nd to 5 th May 2017 Use of the Acoustic Camera to accurately localise wind turbine noise sources and determine their Doppler shift Stuart

More information

ISO 3741 INTERNATIONAL STANDARD

ISO 3741 INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 3741 Fourth edition 2010-10-01 Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Precision methods for reverberation

More information

The effect of environmental and operational variabilities on damage detection in wind turbine blades

The effect of environmental and operational variabilities on damage detection in wind turbine blades The effect of environmental and operational variabilities on damage detection in wind turbine blades More info about this article: http://www.ndt.net/?id=23273 Thomas Bull 1, Martin D. Ulriksen 1 and Dmitri

More information

1. Wind turbines are designed to operate within specified design criteria. Often the operating environment extends beyond these limits and causes

1. Wind turbines are designed to operate within specified design criteria. Often the operating environment extends beyond these limits and causes 1 2 1. Wind turbines are designed to operate within specified design criteria. Often the operating environment extends beyond these limits and causes outages. How these outages are classified can be challenging

More information

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE A.B.N. 73 107 291 494 C O N S U L T I N G A C O U S T I C A L E N G I N E E R S MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE 100 mm ANCIENT STONE BRICK REPORT NUMBER: 4546-2 PREPARED FOR: Timbercrete Pty

More information

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard 92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1

More information

Consumer Guide. Southwest Windpower 1801 W. Route 66 Flagstaff, AZ USA

Consumer Guide. Southwest Windpower 1801 W. Route 66 Flagstaff, AZ USA Consumer Guide wind turbine SITING Southwest Windpower 80 W. Route 66 Flagstaff, AZ 8600 USA www.windenergy.com Introduction Is wind power right for you? Wind generators are an effective source of renewable

More information

Test Report For: FunderMax GmbH. MAX Resistance 2. SEFA , 2.1 Chemical/Stain Resistances

Test Report For: FunderMax GmbH. MAX Resistance 2. SEFA , 2.1 Chemical/Stain Resistances 4700 Broadmoor SE, Suite 200 Kentwood, MI 49512 Telephone: 616-656-7401 Facsimile: 616-656-2022 www.intertek-etlsemko.com P.O. No.: MP Page 1 of 9 Test Report For: FunderMax GmbH MAX Resistance 2 SEFA

More information

Noise Testing and Prediction Methods for Multi-Point Ground Flares

Noise Testing and Prediction Methods for Multi-Point Ground Flares Noise Testing and Prediction Methods for Multi-Point Ground Flares Justin Roberts Flare Applications Engineer, Zeeco American Flame Research Committee (AFRC) Industrial Combustion Symposium September 14,

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION IEC TS 61400-13 First edition 2001-06 Wind turbine generator systems Part 13: Measurement of mechanical loads Aérogénérateurs Partie 13: Mesure des charges mécaniques Reference

More information

FUNDERMAX GMBH TEST REPORT

FUNDERMAX GMBH TEST REPORT FUNDERMAX GMBH TEST REPORT SCOPE OF WORK SEFA 3 2010, 2.1 Analysis of Max Compact Interior Plus White and Black Plaques REPORT NUMBER 103600635GRR 001a ISSUE DATE 25 September 2018 PAGES 22 DOCUMENT CONTROL

More information

Windcube TM Pulsed lidar wind profiler Overview of more than 2 years of field experience J.P.Cariou, R. Parmentier, M. Boquet, L.

Windcube TM Pulsed lidar wind profiler Overview of more than 2 years of field experience J.P.Cariou, R. Parmentier, M. Boquet, L. Windcube TM Pulsed lidar wind profiler Overview of more than 2 years of field experience J.P.Cariou, R. Parmentier, M. Boquet, L.Sauvage 15 th Coherent Laser Radar Conference Toulouse, France 25/06/2009

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 FOR THE SCOPE OF ACCREDITATION UNDER ALA TO ISO/IEC 170:00. REPORT 800 COMMERCENTRE DRIVE, LAKE FOREST, CA 90 Project No. G10171817 Date: August, 01 REPORT NO. 10171817LAX-00 TEST OF ONE GARAUGE LUMINAIRE

More information

ECMA Measurement of airborne noise emitted and structure-borne vibration induced by small air-moving devices Part 1: Airborne noise measurement

ECMA Measurement of airborne noise emitted and structure-borne vibration induced by small air-moving devices Part 1: Airborne noise measurement ECMA-275-1 4 th Edition / December 2017 Measurement of airborne noise emitted and structure-borne vibration induced by small air-moving devices Part 1: Airborne noise measurement Reference number ECMA-123:2009

More information

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT -SA6986/-SA6987 Revision 0 Subject: Sound Absorption Test Date: 01 February 2017 Contents: on Sound Absorption Data, One-third Octave

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

Addendum to ARI Standard , Air Terminals September 2002

Addendum to ARI Standard , Air Terminals September 2002 Addendum to ARI Standard 880-98, Air Terminals September 2002 The September 2002 Addendum to ARI Standard 880-98, Air Terminals, is comprised of only the shaded portions shown, which has been incorporated

More information

Krantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

Krantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems Krantz Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems DS E 01.18 Variable twist outlet with guide ring or jet straightener Preliminary remarks The variable

More information

WIND FARM PERFORMANCE MONITORING WITH ADVANCED WAKE MODELS

WIND FARM PERFORMANCE MONITORING WITH ADVANCED WAKE MODELS Summary WIND FARM PERFORMANCE MONITORING WITH ADVANCED WAKE MODELS N. Mittelmeier 1, S. Amelsberg 3, T. Blodau 1, A. Brand 4, S. Drueke 2, M. Kühn 2, K. Neumann 1, G. Steinfeld 2 1) REpower Systems SE,

More information

Ultra-Small Footprint N-Channel FemtoFET MOSFET Test EVM

Ultra-Small Footprint N-Channel FemtoFET MOSFET Test EVM User's Guide SLPU007 December 07 Ultra-Small Footprint N-Channel FemtoFET MOSFET Test EVM Contents Introduction... Description... Electrical Performance Specifications... 4 Schematic... 4 Test Setup....

More information

McArthur River Mining Borroloola Caravan and Devils Spring Stations

McArthur River Mining Borroloola Caravan and Devils Spring Stations Borroloola Caravan and Devils Spring Ambient Air Quality Monitoring Validated Report 1 st July 2016 31 st July 2016 Report No.: DAT10991 Report issue date: 25 th August 2016 Maintenance contract: MC1100,

More information

IS INTERNATIONAL STANDARD. Acoustics - Determination of sound power levels of noise sources using sound intensity - Part 2:

IS INTERNATIONAL STANDARD. Acoustics - Determination of sound power levels of noise sources using sound intensity - Part 2: INTERNATIONAL STANDARD IS0 9614-2 First edition 1996-08-01 Acoustics - Determination of sound power levels of noise sources using sound intensity - Part 2: Measurement by scanning Acoustique - Dhermination

More information

LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS

LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS Prepared for: MONOGLASS INC. 922-1200 West 73rd Avenue Vancouver, BC, Canada V6P 6G5 Prepared by: THE

More information

WHITE PAPER. Challenges in Sound Measurements Field Testing JUNE 2017

WHITE PAPER. Challenges in Sound Measurements Field Testing JUNE 2017 WHITE PAPER Challenges in Sound Measurements Field Testing JUNE 2017 1 Table of Contents Introduction 3 Sound propagation, simplified approach 3 Sound propagation at ideal conditions 5 Sound propagation

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 140-6 Second edition 1998-08-15 Acoustics Measurement of sound insulation in buildings and of building elements Part 6: Laboratory measurements of impact sound insulation of

More information

z, B1-\T11v10J.\J{TrrE1{ & 1-\~Boc1i~TE33111c. Efl.VIRONMENTAL ENGINEERS AND CONSULTANTS

z, B1-\T11v10J.\J{TrrE1{ & 1-\~Boc1i~TE33111c. Efl.VIRONMENTAL ENGINEERS AND CONSULTANTS vv, z, B1-\T11v10J.\J{TrrE1{ & 1-\~Boc1i~TE33111c. Efl.VIRONMENTAL ENGINEERS AND CONSULTANTS P.O. BOX 680369 FRANKLIN, TN 37068-0369 1113 MURFREESBORO RD., SUITE 310 FRANKLIN, TN 37064 615-595-0025 FAX

More information

Measurement of Acoustic Properties of light weight concrete SL-Deck

Measurement of Acoustic Properties of light weight concrete SL-Deck DELTA Test Report TEST Reg. no. 100 Measurement of Acoustic Properties of light weight concrete SL-Deck Performed for Abeo A/S Project no.: I100486 Page 1 of 25 30 June 2014 DELTA Venlighedsvej 4 2970

More information

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL 400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. July 2013 REV. 015 2013 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix AP Harmonic

More information

Morehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web: sales:

Morehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web:  sales: Morehouse 1 Morehouse Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA 17403 PH: 717-843-0081 web: www.mhforce.com sales: edlane@mhforce.com 2 This presentation will cover the calibration

More information

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Digital Current Transducer HLSR-PW series I P N = 16... 50 A Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement

More information

Correlation of SODAR and Meteorological Tower Measurements. Prepared for: West Virginia Division of Energy

Correlation of SODAR and Meteorological Tower Measurements. Prepared for: West Virginia Division of Energy Correlation of SODAR and Meteorological Tower Measurements Prepared for: West Virginia Division of Energy 4/18/2011 CORRELATION OF SODAR AND MET TOWER MEASUREMENTS Authors: Principal Investigator: Christine

More information

Acoustic test report AU01+N01

Acoustic test report AU01+N01 Customer Industriezeile 35 4021 inz Tel.: +43 732 7664-3105 Fax: +43 732 7664-113 Acoustic test report 110379-AU01+N01 Favorit 5000 IM 04 Select The test result refer exclusively to the model tested. This

More information

WYANDOTTE MUNICIPAL SERVICES COMMUNITY WIND ENERGY PROJECT WIND RESOUCE SUMMARY

WYANDOTTE MUNICIPAL SERVICES COMMUNITY WIND ENERGY PROJECT WIND RESOUCE SUMMARY WYANDOTTE MUNICIPAL SERVICES COMMUNITY WIND ENERGY PROJECT WIND RESOUCE SUMMARY MONTHLY REPORT October 15, 2007 Black & Veatch Project: 144374 Prepared by: Black & Veatch Corporation 6300 S. Syracuse Way

More information

CITY OF STURGIS 1984 REVISED ORDINANCES TITLE 35-1

CITY OF STURGIS 1984 REVISED ORDINANCES TITLE 35-1 CITY OF STURGIS 1984 REVISED ORDINANCES TITLE 35-1 TITLE 35 WIND ENERGY SYSTEMS (Title 35 enacted effective July 21, 2010, Ordinance 2010-06) Chapters: 35.01: General Provisions 35.02: Permitted Use 35.03:

More information

Consultancy Report Ref: 9383-R01

Consultancy Report Ref: 9383-R01 Consultancy Report Ref: 9383-R01 Submitted to: Prepared by: Mr Tim Simmons The Woolley Shepherd Secret Meadow Weekmoor Milverton Taunton TA4 1QE John Fithyan Laboratory Manager Approved for issue by: Andy

More information

WeatherHawk Weather Station Protocol

WeatherHawk Weather Station Protocol WeatherHawk Weather Station Protocol Purpose To log atmosphere data using a WeatherHawk TM weather station Overview A weather station is setup to measure and record atmospheric measurements at 15 minute

More information

WIND DATA REPORT. Rockport School Complex Rockport, Massachusetts

WIND DATA REPORT. Rockport School Complex Rockport, Massachusetts WIND DATA REPORT Rockport School Complex Rockport, Massachusetts June 1, 2007 August 31, 2007 Prepared for Massachusetts Technology Collaborative 75 North Drive Westborough, MA 01581 by William L. W. Henson

More information