1 Radio test report rev 1. based on: FCC part 15; subpart C; section (ed ); FCC part 15, subpart B, section 15.9 (ed ); FCC part 15; subpart B, section 15.7 (ed ) Wireless base station MTw W-

2 Report number: rev 1. Contents MIN MODULE INTRODUCTION PRODUCT TEST SCHEDULE PRODUCT DOCUMENTTION OBSERVTIONS ND COMMENTS MODIFICTIONS TO THE SMPLE SUMMRY CONCLUSIONS... 6 TEST RESULTS MODULE GENERL INFORMTION Equipment information Tested channels EMISSION TESTS Maximum conducted output power Minimum 6 db bandwidth TX unwanted emissions attenuation (conducted,.3 26 GHz) TX unwanted emissions in the restricted bands (radiated,.3-1 GHz) TX unwanted emissions in the restricted bands (radiated, > 1GHz) Maximum power spectral density conducted to the antenna RX unwanted emissions (radiated,.3 1 GHz) RX unwanted emissions (radiated, > 1 GHz) Conducted disturbance measurements USED TEST EQUIPMENT MODULE REVISION HISTORY This report comprises of three modules. The total number of pages is: 26

3 Page: 3 of 26 Main module Report number: rev 1. Main module 1 Introduction This report contains the result of tests performed by: Telefication B.V. Edisonstraat 12a 692 PK Zevenaar The Netherlands Telefication complies with the accreditation criteria for test laboratories as laid down in ISO/IEC 1725:25. The accreditation covers the quality system of the laboratory as well as the specific activities as described in the authorized annex bearing the accreditation number L21 and is granted on 3 November 199 by the Dutch Council For ccreditation (Rv: Raad voor ccreditatie). The contents of this test report, if reproduced, shall be copied in full, unless special consent in writing for reproduction in part is granted by Telefication. Copyright of this test report is reserved to Telefication. Ordering party: Company name : Xsens Technologies B.V. ddress : Pantheon 6a Zipcode : 7521 PR City/town : Enschede Country : The Netherlands Date of order : 12 June 212

4 Page: 4 of 26 Main module Report number: rev 1. 2 Product sample of the following product was submitted for testing: Product description : Wireless base station Manufacturer : Xsens Technologies B.V. Trade mark : MTw Type designation : W- FCC ID : QILW- Hardware version : W Serial number : 2128 Firmware release : Test schedule Tests are carried out in accordance with the specification detailed in chapter 7 Summary of this report. Tests are carried out at the following location: Telefication, Zevenaar The sample of the product is received on: 2 September 212 Tests are carried out between: 25 September and 11 October 212

5 Page: 5 of 26 Main module Report number: rev 1. 4 Product documentation For production of this report the following product documentation has been used: Identification Date MTw_UserManual.docx MTw_SDK_UserManual.docx The above-mentioned documentation will be filed at Telefication for a period of years following the issue of this test report. 5 Observations and comments None 6 Modifications to the sample No modifications are made to the sample. 7 Summary The product is intended for use in the following application area(s): INTENTIONL RDITOR OPERTING IN THE FREQUENCY BND MHz The sample is tested according to the following specification(s): FCC part 15; subpart C; section (ed ); FCC part 15, subpart B, section 15.9 (ed ); FCC part 15; subpart B, section 15.7 (ed )

6 Page: 6 of 26 Main module Report number: rev 1. 8 Conclusions The samples of the product showed NO NON-COMPLINCES to the specification stated in chapter 7 of this report: The results of the tests as stated in this report, are exclusively applicable to the product item as identified in this report. Telefication accepts no responsibility for any stated properties of product items in this test report, which are not supported by the tests as specified in section 7 Summary. ll tests are performed by: name function : ing. J.C. le Clercq : Test Engineer signature : Review of test methods and report by: name function : G.J. Gort : Senior Test Engineer signature : The above conclusions have been verified by the following signatory: Date : 18 January 213 name function : ing.. van der Valk : Manager Laboratory signature :

7 Page: 7 of 26 Test results module Report number: rev 1. Test results module 1 General information 1.1 Equipment information Type of equipment FCC ID Modulation -- Spreading type Bit rate -- Operating frequencies (channel set) Rated RF antenna power Type of antenna ntenna gain Wireless base station QILW- DSSS Channel dbm eirp Monopole, reverse SM connector 2. dbi (max.) Freq (GHz) 1.2 Tested channels Channel , as stated in 1.1 (equipment information).

8 Page: 8 of 26 Test results module Report number: rev 1. 2 Emission tests 2.1 Maximum conducted output power Compliance standard : FCC part 15, subpart C, section (b) (3) Method of test : FCC KDB publication No mbient temperature : 23 C Relative humidity : 47 % Test results : Mode Continuously transmitting Level (dbm) CH 1 CH 2 CH Limit: Maximum conducted output power 3 dbm (antenna gain < 6 dbi) Measurement uncertainty: /- 1.9 db Measurement equipment : 12, 13, 39, 54 (the numbers listed refer to the module 'Used test equipment').

9 Page: 9 of 26 Test results module Report number: rev Minimum 6 db bandwidth Compliance standard : FCC part 15, subpart C, section (a) (2) Method of test : FCC KDB publication No mbient temperature : 23 C Relative humidity : 47 % Test results : R B W 1 k H z D e l t a 1 [ T 1 ] R B W 1 k H z D e l t a 1 [ T 1 ] V B W 3 k H z d B V B W 3 k H z. 2 7 d B R e f 2 d B m t t 5 d B S W T 2. 5 m s M H z R e f 2 d B m t t 5 d B S W T 2. 5 m s M H z 2 M a r k e r 1 [ T 1 ] 2 M a r k e r 1 [ T 1 ] d B m d B m G H z G H z D d B m D d B m C e n t e r G H z 5 k H z / S p a n 5 M H z C e n t e r G H z 5 k H z / S p a n 5 M H z CH 11: - 6dB bandwidth = 1.75 MHz CH 18: -6 db bandwidth = 1.66 MHz Date: 28.SEP.212 :35:3 R B W 1 k H z D e l t a 1 [ T 1 ] V B W 3 k H z d B R e f 2 d B m t t 5 d B S W T 2. 5 m s M H z 2 M a r k e r 1 [ T 1 ] d B m G H z 1 1 D d B m Intentionally left blank C e n t e r G H z 5 k H z / S p a n 5 M H z Limit: CH 25: -6dB bandwidth = 1.68 MHz Date: 28.SEP.212 :37:57 Minimum 6 db bandwidth at least 5 khz Measurement uncertainty: Measurement equipment: + /- 2 khz 39, 42, 54 (the numbers listed refer to the module 'Used test equipment').

10 Page: of 26 Test results module Report number: rev TX unwanted emissions attenuation (conducted,.3 26 GHz) Compliance standard : FCC part 15, subpart C, section (d) Method of test : FCC KDB publication No mbient temperature : 23 C Relative humidity : 47 % Test results : R e f 1 d B m t t 4 d B * R B W 1 k H z V B W 3 k H z S W T 2. 6 s R e f 1 d B m t t 4 d B * R B W 1 k H z V B W 3 k H z S W T 2. 6 s S t a r t 3 M H z G H z / S t o p 2 6 G H z S t a r t 3 M H z G H z / S t o p 2 6 G H z CH 11 Date: 28.SEP.212 :53:2 CH 18 R e f 1 d B m t t 4 d B * R B W 1 k H z V B W 3 k H z S W T 2. 6 s Intentionally left blank S t a r t 3 M H z G H z / S t o p 2 6 G H z Date: 28.SEP.212 :57:25 CH 25 Limit: In any khz bandwidth Measurement uncertainty: < 2 GHz: + 1.7/- 1.9 db; 2 GHz: +2.4/-2.7 db at least 2 db down from the highest emission level within the authorized band as measured with a khz bandwidth. Measurement equipment : 39, 42, 54 (the numbers listed refer to the module 'Used test equipment').

11 Page: 11 of 26 Test results module Report number: rev TX unwanted emissions in the restricted bands (radiated,.3-1 GHz) Compliance standard : FCC part 15, subpart C, section (d) Method of test : FCC KDB publication No mbient temperature : 23 C Relative humidity : 23 % Test results : t t 1 d B R B W 1 2 k H z M T 1 µ s P R E M P O N t t 1 d B R B W 1 2 k H z M T 1 µ s P R E M P O N 1 M H z 1 G H z 1 M H z 1 G H z TDS 7 TDS F C C C F C C C M H z 1 G H z 3 M H z 1 G H z CH 11 (hor. pol.) CH 11 (vert. pol) R B W 1 2 k H z M a r k e r 1 [ T 1 ] R B W 1 2 k H z M a r k e r 1 [ T 1 ] D e m o d M t t 1 d B M T 1 µ s P R E M P O N d B µ V M H z D e m o d M Date: 26.SEP :48:49 t t 1 d B M T 1 µ s P R E M P O N d B µ V M H z 1 M H z 1 G H z 1 M H z 1 G H z TDS 7 TDS F C C C F C C C M H z 1 G H z CH 18 (hor. pol.) 3 M H z 1 G H z CH 18 (vert. pol.) Date: 26.SEP :12:22 Date: 26.SEP :15:34

12 Page: 12 of 26 Test results module Report number: rev 1. D e m o d M t t 1 d B R B W 1 2 k H z M T 1 µ s P R E M P O N D e m o d M t t 1 d B R B W 1 2 k H z M a r k e r 1 [ T 1 ] M T 1 µ s d B µ V P R E M P O N M H z 1 M H z 1 G H z 1 M H z 1 G H z TDS 7 TDS F C C C F C C C M H z 1 G H z 3 M H z 1 G H z Limit: CH 25 (hor. pol.) Date: 26.SEP :18:18 CH 25 (vert. pol.) Field strength at 3 meter distance 3 88 MHz: 4 /m; MHz: 43.5 /m; MHz: 46 /m; bove 96 MHz: 54 /m Measurement uncertainty: Horizontal polarization 3 2 MHz 4.5 db 2 MHz 3.6 db Vertical polarization 3 2 MHz 5.4 db 2 MHz 4.6 db * ) derived from the expression EIRP dbm = E /m 95.2 db (Max. field strength at band edge: 5 3 m distance (equivalent to 54 /m)) Measurement equipment : 34, 36, 39, 43, 54 (the numbers listed refer to the module 'Used test equipment').

13 Page: 13 of 26 Test results module Report number: rev TX unwanted emissions in the restricted bands (radiated, > 1GHz) Compliance standard : FCC part 15, subpart C, section (d) Method of test : FCC KDB publication No mbient temperature : 23 C Relative humidity : 23 % Test results : 1-4 GHz *TTEN db *TTEN db RL -.dbm db/ RL -.dbm db/ Read as dbm EIRP (hor) dec 29 Read as dbm EIRP (ver) dec 29 D D W W STRT 1.GHz STOP 4.GHz STRT 1.GHz STOP 4.GHz *RBW 1.MHz VBW 1.MHz SWP 6.ms CH 11 (hor. pol.) *RBW 1.MHz VBW 1.MHz SWP 6.ms CH 11 (vert. pol) *TTEN db *TTEN db RL -.dbm db/ RL -.dbm db/ Read as dbm EIRP (hor) dec 29 Read as dbm EIRP (ver) dec 29 D D W W STRT 1.GHz STOP 4.GHz STRT 1.GHz STOP 4.GHz *RBW 1.MHz VBW 1.MHz SWP 6.ms CH 18 (hor. pol.) *RBW 1.MHz VBW 1.MHz SWP 6.ms CH 18 (vert. pol.) *TTEN db *TTEN db RL -.dbm db/ RL -.dbm db/ Read as dbm EIRP (hor) dec 29 Read as dbm EIRP (ver) dec 29 D D W W STRT 1.GHz STOP 4.GHz STRT 1.GHz STOP 4.GHz *RBW 1.MHz VBW 1.MHz SWP 6.ms CH 25 (hor. pol.) *RBW 1.MHz VBW 1.MHz SWP 6.ms CH 25 (vert. pol.)

14 Page: 14 of 26 Test results module Report number: rev GHz * R B W 1 M H z * R B W 1 M H z V B W 3 M H z V B W 3 M H z R e f - 2 d B m * t t d B S W T 3 m s R e f - 2 d B m * t t d B S W T 3 m s D d B m -4 D d B m S t a r t 3 G H z 1. 5 G H z / S t o p 1 8 G H z S t a r t 3 G H z 1. 5 G H z / S t o p 1 8 G H z R e f -2-2 d B m CH 11 (hor. pol.) * R B W 1 M H z V B W 3 M H z * t t d B S W T 3 m s Date: 11.OCT :21:32 R e f - 2 d B m * t t d B -2 CH 11 (vert. pol) * R B W 1 M H z V B W 3 M H z S W T 3 m s D d B m -4 D d B m S t a r t 3 G H z 1. 5 G H z / S t o p 1 8 G H z S t a r t 3 G H z 1. 5 G H z / S t o p 1 8 G H z Date: 11.OCT :26:39 CH 18 (hor. pol.) * R B W 1 M H z V B W 3 M H z Date: 11.OCT :22:23 CH 18 (vert. pol.) * R B W 1 M H z V B W 3 M H z R e f - 2 d B m * t t d B S W T 3 m s R e f - 2 d B m * t t d B S W T 3 m s D d B m -4 D d B m S t a r t 3 G H z 1. 5 G H z / S t o p 1 8 G H z S t a r t 3 G H z 1. 5 G H z / S t o p 1 8 G H z CH 25 (hor. pol.) Date: 11.OCT :27:22 CH 25 (vert. pol.) Date: 11.OCT :23:13

15 Page: 15 of 26 Test results module Report number: rev GHz * R B W 1 M H z * R B W 1 M H z V B W 3 M H z V B W 3 M H z R e f - 1 d B m * t t d B S W T 1 6 m s R e f - 1 d B m * t t d B S W T 1 6 m s D d B m -4 D d B m S t a r t 1 8 G H z 8 M H z / S t o p 2 6 G H z S t a r t 1 8 G H z 8 M H z / S t o p 2 6 G H z R e f d B m CH 11 (hor. pol.) * R B W 1 M H z V B W 3 M H z * t t d B S W T 1 6 m s Date: 11.OCT :4:21 CH 11 (vert. pol) * R B W 1 M H z V B W 3 M H z R e f - 1 d B m * t t d B S W T 1 6 m s D d B m -4 D d B m S t a r t 1 8 G H z 8 M H z / S t o p 2 6 G H z S t a r t 1 8 G H z 8 M H z / S t o p 2 6 G H z Date: 11.OCT :6:11 CH 18 (hor. pol.) * R B W 1 M H z Date: 11.OCT :4:47 CH 18 (vert. pol.) * R B W 1 M H z V B W 3 M H z V B W 3 M H z R e f - 1 d B m * t t d B S W T 1 6 m s R e f - 1 d B m * t t d B S W T 1 6 m s D d B m -4 D d B m S t a r t 1 8 G H z 8 M H z / S t o p 2 6 G H z S t a r t 1 8 G H z 8 M H z / S t o p 2 6 G H z CH 25 (hor. pol.) Date: 11.OCT :6:38 CH 25 (vert. pol.) Date: 11.OCT :5:6

16 Page: 16 of 26 Test results module Report number: rev 1. Limit: Radiated power bove 1 GHz: dbm eirp * ) * ) derived from the expression EIRP dbm = E /m 95.2 db (Max. field strength at band edge: 5 3 m distance (equivalent to 54 /m)) Measurement uncertainty : +4.5 / -6.1 db Measurement equipment : 2, 6, 24, 31, 34, 39, 42, 46, 54, 57 (the numbers listed refer to the module 'Used test equipment').

17 Page: 17 of 26 Test results module Report number: rev Maximum power spectral density conducted to the antenna Compliance standard : FCC part 15, subpart C, section (e) Method of test : FCC KDB publication No mbient temperature : 23 C Relative humidity : 23 % Test results : * R B W 3 k H z M a r k e r 1 [ T 1 ] * R B W 3 k H z M a r k e r 1 [ T 1 ] V B W 1 k H z d B m V B W 1 k H z d B m R e f 1 d B m t t 4 d B S W T 5 6 m s G H z R e f 1 d B m t t 4 d B S W T 5 6 m s G H z C e n t e r G H z 5 k H z / S p a n 5 M H z C e n t e r G H z 5 k H z / S p a n 5 M H z CH 1 CH 2 * R B W 3 k H z M a r k e r 1 [ T 1 ] Date: 28.SEP :14:56 V B W 1 k H z d B m R e f 1 d B m t t 4 d B S W T 5 6 m s G H z Intentionally left blank C e n t e r G H z 5 k H z / S p a n 5 M H z Date: 28.SEP :18:13 CH 3 Measurement uncertainty: Limit: In any 3 khz band < 2 GHz: + 1.7/- 1.9 db; 2 GHz: + 2.4/- 2.7 db Not greater than 8 dbm during any time of continous transmission Measurement equipment: 39, 42, 54 (the numbers listed refer to the module 'Used test equipment')

18 Page: 18 of 26 Test results module Report number: rev RX unwanted emissions (radiated,.3 1 GHz) Compliance standard : FCC part 15, subpart B, section 15.9 Method of test : NSI C63.-29, section mbient temperature : 23 C Relative humidity : 23 % Test results : R B W 1 2 k H z R B W 1 2 k H z D e m o d M M T 1 µ s D e m o d M M T 1 µ s t t 1 d B P R E M P O N t t 1 d B P R E M P O N 1 M H z 1 G H z 1 M H z 1 G H z TDS 7 TDS F C C C F C C C M H z 1 G H z 3 M H z 1 G H z CH 11 (hor. pol.) CH 11 (vert. pol) R B W 1 2 k H z R B W 1 2 k H z D e m o d M t t 1 d B M T 1 µ s P R E M P O N D e m o d M Date: 27.SEP.212 9:8:4 t t 1 d B M T 1 µ s P R E M P O N 1 M H z 1 G H z 1 M H z 1 G H z TDS 7 TDS F C C C F C C C M H z 1 G H z 3 M H z 1 G H z CH 18 (hor. pol.) CH 18 (vert. pol.) Date: 27.SEP.212 9:11:43 Date: 27.SEP.212 9::

19 Page: 19 of 26 Test results module Report number: rev 1. R B W 1 2 k H z R B W 1 2 k H z D e m o d M M T 1 µ s D e m o d M M T 1 µ s t t 1 d B P R E M P O N t t 1 d B P R E M P O N 1 M H z 1 G H z 1 M H z 1 G H z TDS 7 TDS F C C C F C C C M H z 1 G H z 3 M H z 1 G H z CH 25 (hor. pol.) CH 25 (vert. pol.) Limit: Date: 27.SEP.212 9:13:49 Field strength at 3 meter distance 3 88 MHz: 4 /m; MHz: 43.5 /m; MHz: 46 /m; bove 96 MHz: 54 /m Measurement uncertainty: Horizontal polarization 3 2 MHz 4.5 db 2 MHz 3.6 db Vertical polarization 3 2 MHz 5.4 db 2 MHz 4.6 db Measurement equipment : 34, 36, 39, 43, 54 (the numbers listed refer to the module 'Used test equipment').

20 Page: 2 of 26 Test results module Report number: rev RX unwanted emissions (radiated, > 1 GHz) Compliance standard : FCC part 15, subpart B, section 15.9 Method of test : NSI C63.-29: section 6.6 mbient temperature : 23 C Relative humidity : 23 % Test results : *TTEN db *TTEN db RL -.dbm db/ RL -.dbm db/ Read as dbm EIRP (hor) dec 29 Read as dbm EIRP (ver) dec 29 D D W W STRT 1.GHz STOP 13.GHz STRT 1.GHz STOP 13.GHz *RBW 1.MHz VBW 1.MHz SWP 24ms *TTEN db CH 11 (hor. pol.) *RBW 1.MHz VBW 1.MHz SWP 24ms *TTEN db CH 11 (vert. pol) RL -.dbm db/ RL -.dbm db/ Read as dbm EIRP (hor) dec 29 Read as dbm EIRP (ver) dec 29 D D W W STRT 1.GHz STOP 13.GHz STRT 1.GHz STOP 13.GHz *RBW 1.MHz VBW 1.MHz SWP 24ms CH 18 (hor. pol.) *RBW 1.MHz VBW 1.MHz SWP 24ms CH 18 (vert. pol.)

21 Page: 21 of 26 Test results module Report number: rev 1. *TTEN db *TTEN db RL -.dbm db/ RL -.dbm db/ Read as dbm EIRP (hor) dec 29 Read as dbm EIRP (ver) dec 29 D D W W STRT 1.GHz STOP 13.GHz STRT 1.GHz STOP 13.GHz *RBW 1.MHz VBW 1.MHz SWP 24ms CH 25 (hor. pol.) *RBW 1.MHz VBW 1.MHz SWP 24ms CH 25 (vert. pol.) Limit: Radiated power bove 1 GHz: dbm eirp * ) * ) derived from the expression EIRP dbm = E /m 95.2 db (Max. field strength at band edge: 5 3 m distance (equivalent to 54 /m)) Measurement uncertainty: +4.5 / -6.1 db Measurement equipment : 2, 6, 24, 31, 34, 39, 42, 46, 54 (the numbers listed refer to the module 'Used test equipment').

22 Page: 22 of 26 Test results module Report number: rev Conducted disturbance measurements Compliance standard : FCC part 15, subpart B, section 15.7(a). Method of test : NSI C63.: 29, section 6.2 Port : C power input, 12 Volt Mode : normal usage mode Configuration : The sample was continuously activated tmospheric pressure : Between 86 kpa and 6 kpa Temperature : 23 C Relative humidity : 4 % Test results : Plots and tables Type W-, live wire, plot t t 1 d B U T O R B W 9 k H z M T 1 s P R E M P O F F 8 1 M H z 1 M H z CLRWR 2 V CLRWR 7 Q P V G SGL 4 3 C k H z 3 M H z Type W-, live wire, table Date: 27.SEP :53:42 E D I T P E K L I S T ( F i n a l M e a s u r e m e n t R e s u l t s ) T r a c e 1 : Q P T r a c e 2 : V G T r a c e 3 : T R C E F R E Q U E N C Y L E V E L d B µ V D E L T L I M I T d B 1 Q u a s i P e a k k H z Q u a s i P e a k 1 9 k H z v e r a g e k H z Q u a s i P e a k 4 3 k H z Q u a s i P e a k k H z v e r a g e 1 9 k H z v e r a g e k H z v e r a g e 4 3 k H z Q u a s i P e a k k H z Q u a s i P e a k k H z v e r a g e 6 5 k H z Q u a s i P e a k k H z v e r a g e k H z Q u a s i P e a k 3 5 k H z v e r a g e k H z v e r a g e k H z v e r a g e k H z v e r a g e M H z Q u a s i P e a k M H z Q u a s i P e a k k H z

23 Page: 23 of 26 Test results module Report number: rev 1. Type W-, neutral wire, plot t t 1 d B U T O R B W 9 k H z M T 1 s P R E M P O F F 8 1 M H z 1 M H z CLRWR 2 V CLRWR 7 Q P V G SGL 4 3 C k H z 3 M H z Type W-, neutral wire, table Date: 27.SEP :5:45 E D I T P E K L I S T ( F i n a l M e a s u r e m e n t R e s u l t s ) T r a c e 1 : Q P T r a c e 2 : V G T r a c e 3 : T R C E F R E Q U E N C Y L E V E L d B µ V D E L T L I M I T d B 2 v e r a g e k H z Q u a s i P e a k k H z Q u a s i P e a k 1 9 k H z Q u a s i P e a k k H z v e r a g e 1 9 k H z Q u a s i P e a k k H z v e r a g e k H z Q u a s i P e a k 3 5 k H z v e r a g e k H z v e r a g e k H z v e r a g e k H z Q u a s i P e a k k H z Q u a s i P e a k k H z v e r a g e 6 5 k H z v e r a g e 7 7 k H z v e r a g e M H z v e r a g e M H z Q u a s i P e a k k H z v e r a g e M H z v e r a g e M H z Result : Pass Measurement uncertainty : Date: 27.SEP :5:29 +/- 3.6 db. The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approx. 95%, but excluding the effect of measurement system repeatability. Measurement equipment : 39, 43, 55, 54, 56 (the numbers listed refer to the module 'Used test equipment').

24 Page: 24 of 26 Used test equipment Report number: rev 1. Used test equipment module Item Description Manufacturer Type ID 1 Signal generator Marconi 242 TE 3 2 Preamplifier GHz HP 8449B TE 92 3 Preamplifier GHz HP 8449B TE 93 4 Pre-amplifier db R & S ESV-Z3 TE 97 5 Pre-amplifier db R & S ESV-Z3 TE 98 6 Spectrum analyser HP 8562E TE 99 7 Microwave amplifier HP HP8349 TE Digital multimeter HP 3441 TE Digital multimeter HP 3438 TE 215 Step attenuator HP 8494 TE Step attenuator HP 8496 TE Power sensor HP 8484 TE Power meter HP 435B TE Power meter HP 437B TE Power sensor HP 8481 TE Spectrum analyser HP 8563E TE udio analyzer HP 893 TE Signal generator Marconi 242 TE Digital thermometer Fluke 51 TE Step attenuator HP 8491 TE Signal generator HP 8642B TE Signal generator Marconi 242 TE Spectrum analyser HP 8563E TE Horn antenna EMCO 3115 TE Horn antenna EMCO 3116 TE Biconilog antenna EMCO 3143 TE 7 27 Climate chamber CTS C-4/35 TE ctive loop antenna R & S HFH2-Z2 TE Horn antenna Quinstar QWH-19- TE 747

25 Page: 25 of 26 Used test equipment Report number: rev 1. Item Description Manufacturer Type ID 3 Step attenuator HP 8491 TE Standard gain horn Flann TE Power supply for amplifier R & S HZ-9 TE Power supply Delta Elektronika E3-1 TE Semi nechoic Room Comtest -- TE Power supply Delta Elektronika MST3- TE Biconilog antenna Chase CBL6112 TE nechoic chamber Euroshield RFB-F- TE Triple loop antenna Telefication -- TE Temp / RH logger MicroLog EC 65 TE Broadband resistive power divider Weinschel 156 TE Broadband resistive power divider Weinschel 156 TE Spectrum analyser R & S FSP 4 TE EMI test receiver R & S ESCI TE Radio Communication Service Monitor R & S CMS54 TE Pre-amplifier Miteq JS4-184 TE Low noise amplifier Miteq FS TE ntenna tower Heinrich Deisel S 62P NEC 48 Turntable Heinrich Deisel DS-412 NEC 49 Turntable controller Heinrich Deisel HD-5 NEC 5 ntenna mast EMCO 7 SR 51 Turn table EMCO 6-2M SR 52 Near field probe Digital multimeter Fluke 87 TE Variable transformer KSL RU8 TE Two line V-network R & S ESH3-Z5 TE Pulse limiter R & S ESH3-Z2 TE High pass filter Wainwright WHK3. TE 114

26 Page: 26 of 26 Revision history Report number: rev 1. Revision history REVISION DTE REMRKS REVISED BY January 213 Power density plots added on page 17 J.C. le Clercq

FCC RADIO TEST REPORT

FCC RADIO TEST REPORT Statement FCC RDIO TEST REPORT Equipment Model No. Brand Name Filing Type pplicant Manufacturer according to 47 CFR FCC Part 5 Subpart C 5.247 FCC ID Received Date : Mar. 23, 2 Final Test Date : May 2,

More information

CE Test Report. : abn (1x1) + Bluetooth (2.1) module

CE Test Report. : abn (1x1) + Bluetooth (2.1) module CE Test Report Equipment Model No. Brand Name Applicant : 802.11abn (1x1) + Bluetooth (2.1) module : SDC-SSD40NBT : Laird Technologies : Laird Technologies Address : 11160 Thompson Ave., Lenexa, Kansas

More information

SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY CO., LTD

SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY CO., LTD SAR Reference Dipole Calibration Report Ref : ACR.189.7.16.SATU.A SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY CO., LTD FL3, BUILDING A, FEIYANG SCIENCE PARK, NO.8 LONGCHANG ROAD, BLOCK 67, BAOAN DISTRICT,

More information

III. Spherical Waves and Radiation

III. Spherical Waves and Radiation III. Spherical Waves and Radiation Antennas radiate spherical waves into free space Receiving antennas, reciprocity, path gain and path loss Noise as a limit to reception Ray model for antennas above a

More information

The Challenge is to Define: System Engineering. System Engineering Components. Functional Requirements

The Challenge is to Define: System Engineering. System Engineering Components. Functional Requirements The Challenge is to Define: System Engineering What it is supposed to do How well it must do it It s constituant parts and how they play together We are not prepared for detail design, assembly and test

More information

CERTIFICATE OF CALIBRATION

CERTIFICATE OF CALIBRATION Page 1 of 10 CALIBRATION OF Sound Level Meter: Brüel & Kjær Type 3050-A-040 No: 3050-100751 Id: - Microphone: Brüel & Kjær Type 4189 No: 2621142 Preamplifier: Brüel & Kjær Type 2669 No: 2679073 Supplied

More information

Orbit and Transmit Characteristics of the CloudSat Cloud Profiling Radar (CPR) JPL Document No. D-29695

Orbit and Transmit Characteristics of the CloudSat Cloud Profiling Radar (CPR) JPL Document No. D-29695 Orbit and Transmit Characteristics of the CloudSat Cloud Profiling Radar (CPR) JPL Document No. D-29695 Jet Propulsion Laboratory California Institute of Technology Pasadena, CA 91109 26 July 2004 Revised

More information

SHENZHEN SEM.TEST TECHNOLOGY CO., LTD. 1/F, BUILDING A, HONGWEI INDUSTRIAL PARK, LIUXIAN 2ND ROAD BAO'AN DISTRICT SHENZHEN (518101), CHINA

SHENZHEN SEM.TEST TECHNOLOGY CO., LTD. 1/F, BUILDING A, HONGWEI INDUSTRIAL PARK, LIUXIAN 2ND ROAD BAO'AN DISTRICT SHENZHEN (518101), CHINA COMOSAR E-Field Probe Calibration Report Ref : ACR.154.4.15.SATU.A SHENZHEN SEM.TEST TECHNOLOGY CO., LTD. 1/F, BUILDING A, HONGWEI INDUSTRIAL PARK, LIUXIAN 2ND ROAD BAO'AN DISTRICT SHENZHEN (518101), CHINA

More information

COMOSAR E-FIELD PROBE CALIBRATION REPORT

COMOSAR E-FIELD PROBE CALIBRATION REPORT Page: 1/26 Issue: A Date: 2008/10/06 COMOSAR E-FIELD PROBE CALIBRATION REPORT Prepared By: Project Description: Prepared For (End User): LUC Jérôme, SATIMO SAR TEST BENCH Shenzhen Morlab Communication

More information

CERTIFICATE OF CALIBRATION

CERTIFICATE OF CALIBRATION Page 1 of 10 CALIBRATION OF Sound Level Meter: Brüel & Kjær Type 3050-A-040 No: 3050-100751 Id: - Microphone: Brüel & Kjær Type 4189 No: 2621142 Preamplifier: Brüel & Kjær Type 2669 No: 2803547 Supplied

More information

Certificate of Calibration Sound Level Calibrator

Certificate of Calibration Sound Level Calibrator NATacoustic Acoustic Caliration & Testing Laoratory Level, 48A Elizaeth Street., Surry Hills NSW 200 AUSTRALIA Ph: (02) 828 0570 email: service@natacoustic.com.au wesite: www.natacoustic.com.au A division

More information

Test Report EN (2008)

Test Report EN (2008) Test Report EN 62233 (2008) Product Name and address of the applicant Name and address of the manufacturer Model Rating Brand name Heating elements for building into floors Advanced Heating Technologies

More information

Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator

Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator Technical Note The Fluke Calibration 5128A RHapid-Cal Humidity Generator provides a portable, stable test environment

More information

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method INTERNATIONAL STANDARD ISO 10494 Second edition 2018-04 Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method Turbines et groupes de turbines Mesurage du bruit aérien

More information

Instrument Test Report ITR 656. Evaluation of Milos 500 AWS unit

Instrument Test Report ITR 656. Evaluation of Milos 500 AWS unit Instrument Test Report ITR 656 Evaluation of Milos 500 AWS unit Glenn Bowkett Physics Laboratory, OEB 23 November, 1999 Authorisation Tasia Livaditis A/LAB Physics Laboratory Distribution All RDs, ROMs,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 RS CALIBRATION SERVICES, INC. 1047 Serpentine Lane Pleasanton, CA 94566 Mr. Ralph Sabiel Phone: 925 462 4217 CALIBRATION Valid To: April

More information

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard 92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1

More information

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation TFI Report 462257-01 Sound Absorption Impact Sound Insulation Customer Desso B.V. Taxandriaweg 15 5142 PA Waalwijk NETHERLANDS Product textile floor covering This report includes 2 pages and 2 annex(es)

More information

Use of the decibel and the neper

Use of the decibel and the neper Rec. ITU-R V.574-4 1 RECOMMENDATION ITU-R V.574-4 USE OF THE DECIBEL AND THE NEPER IN TELECOMMUNICATIONS*, **, *** Rec. ITU-R V.574-4 (1978-1982-1986-1990-2000) Scope This text recommends the symbols to

More information

CERTIFICATE OF CALIBRATION

CERTIFICATE OF CALIBRATION CERTIFICATE OF CALIBRATION 12100 WEST 6TH AVE LAKEWOOD, CO 80228 ANAB AC-2489.02 Manufacturer: Ruska Instruments Corp. Model Number: 7250i : Pressure Calibrator Serial Number: 69718 ID: TE10768 As-Found:

More information

5730A High Performance Multifunction Calibrator. Extended specifications

5730A High Performance Multifunction Calibrator. Extended specifications 730A High Performance Multifunction Calibrator Extended specifications General Specifications Warm-Up Time... Twice the time since last warmed up, to a maximum of 30 minutes. System Installation... Rack

More information

Part 5: Total stations

Part 5: Total stations Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 17123-5 Third edition 2018-02 Optics and optical instruments Field procedures for testing geodetic and surveying instruments Part 5: Total stations

More information

CS6956: Wireless and Mobile Networks Lecture Notes: 2/4/2015

CS6956: Wireless and Mobile Networks Lecture Notes: 2/4/2015 CS6956: Wireless and Mobile Networks Lecture Notes: 2/4/2015 [Most of the material for this lecture has been taken from the Wireless Communications & Networks book by Stallings (2 nd edition).] Effective

More information

CERTIFICATE OF CALIBRATION

CERTIFICATE OF CALIBRATION Issued By Transmille Ltd. Date of Issue 20 January 2016 0324 Approved Signatory Transmille Ltd. Unit 4, Select Business Centre Lodge Road Staplehurst, Kent. TN12 0QW. TEL 01580 890700 FAX 01580 890711

More information

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard 92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1

More information

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541 Product Data Sound Intensity Calibrator Type 3541 USES: Sound intensity and particle velocity calibrations Sound pressure calibration Measurement of pressure-residual intensity index FEATURES: Intensity

More information

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation TFI Report 481380-01 Sound Absorption Impact Sound Insulation Customer NEWSPEC CARPET (NINGBO) CO. LTD Cevin Yindong South Road NO. 399 315100 Ningbo CHINA VR Product textile floor covering This report

More information

CALIBRATION CERTIFICATE # 503

CALIBRATION CERTIFICATE # 503 CALIBRATION CERTIFICATE # 503 Calibration date : 2011-02-23 Certificate issued : 2012-04-18 Company name Company address City, Province, Canada CLAS 2009-02 Calibration of Mass flow meter Micro Motion

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: AMC LABS S.A de C.V (Hereinafter called the Organization)

More information

Electrical Test Report on PS3300 Series Uninterruptible Power Supply for Powerstar Inc. Gaithersburg MD

Electrical Test Report on PS3300 Series Uninterruptible Power Supply for Powerstar Inc. Gaithersburg MD Test Report No. 10746.1 No. of Pages 88 Electrical Test Report on PS3300 Series Uninterruptible Power Supply for Powerstar Inc. Gaithersburg MD Prepared by NU Laboratories, Inc. 312 Old Allerton Road,

More information

Interlaboratory Comparison & Proficiency Testing Program

Interlaboratory Comparison & Proficiency Testing Program Extended scope for the organization of proficiency tests in accordance with the requirements of ISO/IEC 17043 VSL, the Dutch Metrology Institute, has significantly extended the scope for their accreditation

More information

Interlaboratory Comparison & Proficiency Testing Program

Interlaboratory Comparison & Proficiency Testing Program Extended scope for the organization of proficiency tests in accordance with the requirements of ISO/IEC 17043 VSL, the Dutch Metrology Institute, has significantly extended the scope for their accreditation

More information

Mobile Radio Communications

Mobile Radio Communications Course 3: Radio wave propagation Session 3, page 1 Propagation mechanisms free space propagation reflection diffraction scattering LARGE SCALE: average attenuation SMALL SCALE: short-term variations in

More information

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation TFI Report 471194-01 Sound Absorption Impact Sound Insulation Customer egetaepper a/s Industrivej Nord 25 7400 Herning DENMARK Product textile floor covering This report includes 2 pages and 2 annex(es)

More information

Consultancy Report Ref: 9383-R01

Consultancy Report Ref: 9383-R01 Consultancy Report Ref: 9383-R01 Submitted to: Prepared by: Mr Tim Simmons The Woolley Shepherd Secret Meadow Weekmoor Milverton Taunton TA4 1QE John Fithyan Laboratory Manager Approved for issue by: Andy

More information

Provläsningsexemplar / Preview TECHNICAL REPORT INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE

Provläsningsexemplar / Preview TECHNICAL REPORT INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE TECHNICAL REPORT CISPR 16-4-1 2003 AMENDMENT 1 2004-12 INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE Amendment 1 Specification for radio disturbance and immunity measuring apparatus and methods

More information

Interlaboratory Comparison & Proficiency Testing Program

Interlaboratory Comparison & Proficiency Testing Program Extended scope for the organization of proficiency tests in accordance with the requirements of ISO/IEC 17043 VSL, the Dutch Metrology Institute, has significantly extended the scope for their accreditation

More information

Appendix D Probe Calibration Data Sheets

Appendix D Probe Calibration Data Sheets FCC ID: BYMHS6000 Appendix D Probe Calibration Data Sheets 2005 RF Exposure Lab, LLC Page 55 of 81 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 PROTEMP MECHANICAL, INC. 3350 Scott Blvd, Bldg. #3 Santa Clara, CA 95054 Martin L. Reich Phone: 408 244 9821 CALIBRATION Valid To: August

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS 38654 CONNIE FOSTER PHONE: 800 327 7727 CALIBRATION Valid To: August 31, 2019 Certificate Number:

More information

POWER QUALITY MEASUREMENT PROCEDURE. Version 4 October Power-Quality-Oct-2009-Version-4.doc Page 1 / 12

POWER QUALITY MEASUREMENT PROCEDURE. Version 4 October Power-Quality-Oct-2009-Version-4.doc Page 1 / 12 POWER QUALITY MEASUREMENT PROCEDURE Version 4 October 2009 Power-Quality-Oct-2009-Version-4.doc Page 1 / 12 MEASNET 2009 Copyright all rights reserved This publication may not be reproduced or utilized

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Hards Laboratories cc, t/a Technology Solutions

More information

Mason Technology Ltd

Mason Technology Ltd Mason Technology Ltd 228 South Circular Road, Dublin 8 Calibration Laboratory Registration number: 043C is accredited by the Irish National Board (INAB) to undertake calibration as detailed in the Schedule

More information

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC LVD TEST REPORT

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC LVD TEST REPORT CETRE OF TESTIG SERVICE ITERATIOAL OERATE ACCORDIG TO ISO/IEC 17025 LVD TEST REORT TEST REORT UMBER : CB3160607-00480-L Report o.: CB3160607-00480-L age 1 of 17 Date: 13 June 2016 Table of contents 1.

More information

The information included in the following report presents the results of sound pressure and sound power testing.

The information included in the following report presents the results of sound pressure and sound power testing. ISO 7779:2010 Acoustics -- Measurement of airborne noise emitted by information technology and telecommunications equipment 1 of 14 DEVICES - solid panel case - window panel case Report Date: 06/25/2015

More information

PRODUCT DATA. Sound Intensity Calibrator Type 3541-A. Uses and Features

PRODUCT DATA. Sound Intensity Calibrator Type 3541-A. Uses and Features PRODUCT DATA Sound Intensity Calibrator Type 3541-A Type 3541-A enables calibration of sound intensity measuring instruments by using a coupler designed especially for sound intensity calibrations. Intensity-probe

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Palenque 1 A, Bello Horizonte,. (Hereinafter called

More information

MAINTENANCE AND CALIBRATION REPORT NATIONAL PARK SERVICE GASEOUS POLLUTANT MONITORING NETWORK BADLANDS NATIONAL PARK MAY 10, 2006

MAINTENANCE AND CALIBRATION REPORT NATIONAL PARK SERVICE GASEOUS POLLUTANT MONITORING NETWORK BADLANDS NATIONAL PARK MAY 10, 2006 MAINTENANCE AND CALIBRATION REPORT NATIONAL PARK SERVICE GASEOUS POLLUTANT MONITORING NETWORK BADLANDS NATIONAL PARK MAY 10, 2006 prepared for John Ray NATIONAL PARK SERVICE Research and Monitoring Branch

More information

Understanding the uncertainties associated with using the 5128A RHapid Cal portable humidity generator

Understanding the uncertainties associated with using the 5128A RHapid Cal portable humidity generator Understanding the uncertainties associated with using the 5128A RHapid Cal portable humidity generator Introduction Humidity generators are mechanical devices that provide stable temperature and humidity

More information

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000 Page 1 of 11 Report Reference No... : TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000 93702-1TRFENV Tested by... : Cristian Simone.. Verified by... : Daniele Claudio Mapelli. Date of issue... : 2007-09-28

More information

The Fundamentals of Moisture Calibration

The Fundamentals of Moisture Calibration The Fundamentals of Moisture The following guide will provide you with a basic knowledge of humidity calibration, help you to understand your requirements and select an appropriate solution. 1 Why Humidity

More information

Millimeter and Tera-Hertz waves applications for communications and homeland security

Millimeter and Tera-Hertz waves applications for communications and homeland security ה מרכז האוני ברסיטאי אריאל Ariel University Center of Samaria בשומרון ה מ חל ק ה ל הנ דס ת ח ש מל ו אל קט רונ יק ה Dept. of Electrical and Electronic Engineering Millimeter and Tera-Hertz waves applications

More information

NSG 4070C APPLICATION FOR MIL-STD 461G CS 114

NSG 4070C APPLICATION FOR MIL-STD 461G CS 114 out < +0 meter ch. < +0 ch. < +0 ch. < +7 M nd NSG 0C APPLICATION FOR MIL-STD G CS Test parameter Equipment Standard: MIL-STD G CS Frequency range: to 00 M Curve to : see diagrams Modulation: pulse modulation,

More information

Uncertainties associated with the use of a sound level meter

Uncertainties associated with the use of a sound level meter NPL REPORT DQL-AC 002 Uncertainties associated with the use of a sound level meter Richard Payne April 2004 April 2004 ABSTRACT Uncertainties associated with the use of a sound level meter Richard Payne

More information

Copyright , Larry Randall, d/b/a The NRE Group All Rights Reserved

Copyright , Larry Randall, d/b/a The NRE Group All Rights Reserved NEAR VERTICAL INCIDENCE SKYWAVE (NVIS) Larry Randall -WA5BEN The NRE Group larry@nregroup.net Revision: 1.6 Issue Date: 06 Nov 2014 Copyright 2007 2015, Larry Randall, d/b/a The NRE Group All Rights Reserved

More information

CERTIFICATE OF CALIBRATION

CERTIFICATE OF CALIBRATION Page 1 of 5 CERTIFICATE OF CALIBRATION 1K Thermistor CERTIFICATE NO.: MANUFACTURER: Measurement Specialties DATE OF CALIBRATION: 26-Apr-17 TC15249 CUSTOMER: AMBIENT TEMPERATURE: (21 ± 3) C JOB NUMBER:

More information

VID3: Sampling and Quantization

VID3: Sampling and Quantization Video Transmission VID3: Sampling and Quantization By Prof. Gregory D. Durgin copyright 2009 all rights reserved Claude E. Shannon (1916-2001) Mathematician and Electrical Engineer Worked for Bell Labs

More information

EDITION 1 OCTOBER 1997 EA-10/09 PAGE 1 OF

EDITION 1 OCTOBER 1997 EA-10/09 PAGE 1 OF European cooperation for Accreditation of Laboratories Publication Reference EAL-G32 Measurement and Generation of Small AC Voltages with Inductive Voltage Dividers PURPOSE This document has been produced

More information

Near Vertical Incidence Skywave (NVIS)

Near Vertical Incidence Skywave (NVIS) Near Vertical Incidence Skywave (NVIS) Larry Randall WA5BEN WA5BEN@ARRL.NET Revision: 1.4.5 Issue Date: 17 October 2007 Topics Terminology Why do we need NVIS Defining NVIS Relationship between Path Length

More information

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation TFI Report 480781-01 Sound Absorption Impact Sound Insulation Customer egetaepper a/s Industrivej Nord 25 7400 Herning DENMARK Product textile floor covering This report includes 2 pages and 2 annex(es)

More information

Comparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576

Comparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576 NPL REPORT CMAM 73 Comparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576 Peter Hanes October 2001 The National Physical Laboratory is operated on behalf

More information

Winds on Titan: First results from the Huygens Doppler Wind Experiment

Winds on Titan: First results from the Huygens Doppler Wind Experiment 1 Winds on Titan: First results from the Huygens Doppler Wind Experiment Supplementary Discussion. It was realized during the DWE design phase that Earth-based Doppler measurements could be combined with

More information

Fabric REFLECTACOUSTIC

Fabric REFLECTACOUSTIC Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

Part 2: Methods for special reverberation test rooms

Part 2: Methods for special reverberation test rooms Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 3743-2 Second edition 2018-02 Acoustics Determination of sound power levels of noise sources using sound pressure Engineering methods for small,

More information

Review Quantitative Aspects of Networking. Decibels, Power, and Waves John Marsh

Review Quantitative Aspects of Networking. Decibels, Power, and Waves John Marsh Review Quantitative spects of Networking Decibels, ower, and Waves John Marsh Outline Review of quantitative aspects of networking Metric system Numbers with Units Math review exponents and logs Decibel

More information

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems Test Report issued under the responsibility of: TEST REORT and/or EN 62471 hotobiological safety of lamps and lamp systems Report Reference No.... : GZES160200176431 Tested by (name + signature)... : Jack

More information

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

2.1. Accuracy, n- how close the indication of the thermometer is to the true value. AASHTO Accreditation Policy and Guidance on Thermometer Selection and Records Revised: January 25, 2018 Revision #: 0 1. Objective 1.1. The purpose of this document is to clearly define acceptance criteria

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 EQUIPMENT SERVICES GROUP, LLC 3269 Hilton Rd. Ferndale, MI 48220 Michael Macauley Phone: 248 227 5310 CALIBRATION Valid To: December

More information

Prepare for this experiment!

Prepare for this experiment! Notes on Experiment #8 Theorems of Linear Networks Prepare for this experiment! If you prepare, you can finish in 90 minutes. If you do not prepare, you will not finish even half of this experiment. So,

More information

Observation of neutral hydrogen using FFT spectrometer Argos on a 5m telescope

Observation of neutral hydrogen using FFT spectrometer Argos on a 5m telescope Research Collection Report Observation of neutral hydrogen using FFT spectrometer Argos on a 5m telescope Author(s): Monstein, Christian; Meyer, Hansueli Publication Date: 2006 Permanent Link: https://doi.org/10.3929/ethz-a-005228693

More information

Quantifying and Verifying trace stability of vector network analyzers at frequencies below 1GHz

Quantifying and Verifying trace stability of vector network analyzers at frequencies below 1GHz 1 Quantifying and Verifying trace stability of vector network analyzers at frequencies below 1GHz Hamdi Mani, Chris Groppi, Judd Bowman Abstract we describe measurements done to check the low frequency

More information

RAPID growth in satellite-communications and mobile-communications

RAPID growth in satellite-communications and mobile-communications Calculate The Uncertainty Of N Measurements Simple modifications to the basic noise-figure equations can help in predicting uncertainties associated with test equipment. Duncan Boyd Senior Hardware Development

More information

IEEE Broadband Wireless Access Working Group <

IEEE Broadband Wireless Access Working Group < Project Title IEEE 802.6 Broadband Wireless Access Working Group Codebook based pre-coding MIMO Date Submitted Source(s) 2008-05-05 Jaewan Kim, Wookbong Lee, Bin-chul Ihm Voice:

More information

E C t y p e - e x a m i n a t i o n C e r t i f i c a t e

E C t y p e - e x a m i n a t i o n C e r t i f i c a t e E C t y p e - e x a m i n a t i o n C e r t i f i c a t e Page 1 of 1 Issued by Manufacturer NMi Certin B.V., designated and notified by the Netherlands to perform tasks with respect to conformity modules

More information

Fabric Sport. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/02

Fabric Sport. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/02 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Germany Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

Determination of particle size distribution Single particle light interaction methods. Part 4:

Determination of particle size distribution Single particle light interaction methods. Part 4: Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 21501-4 Second edition 2018-05 Determination of particle size distribution Single particle light interaction methods Part 4: Light scattering airborne

More information

OPTO Laboratory Test Report IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCE. Test Date January 16, 2014 to April 8, 2015.

OPTO Laboratory Test Report IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCE. Test Date January 16, 2014 to April 8, 2015. IES LM-80-08 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCE Report Number Test Sample Q131107 2T03X5WW11000003 Rating DC 150mA 0.5W Normal CCT 2,700 K Test Date January 16, 2014 to April 8, 2015 Test

More information

Reference Only Spec. No. JEFL243B 0003F-01 P 1/ 6

Reference Only Spec. No. JEFL243B 0003F-01 P 1/ 6 Spec. No. JEFL243B 0003F-01 P 1/ 6 DC Common Mode Choke Coil PLT09HN2003R0P1B Reference Specification 1. Scope This reference specification applies to DC Common Mode Choke Coil (PLT09H Series). 2. Part

More information

EE194-EE290C. 28 nm SoC for IoT. Acknowledgement: Wayne Stark EE455 Lecture Notes, University of Michigan

EE194-EE290C. 28 nm SoC for IoT. Acknowledgement: Wayne Stark EE455 Lecture Notes, University of Michigan EE194-EE290C 28 nm SoC for IoT Acknowledgement: Wayne Stark EE455 Lecture Notes, University of Michigan Noise Unwanted electric signals come from a variety of sources, both from - Naturally occurring noise

More information

BEng. (Hons) Electronics Engineering. Examinations for / Semester 2

BEng. (Hons) Electronics Engineering. Examinations for / Semester 2 BEng. (Hons) Electronics Engineering Cohort: BTEL/11/FT Examinations for 2013-2014/ Semester 2 MODULE: ELECTROMAGNETIC COMPATIBILITY MODULE CODE: TELC3110 Duration: 2 ½ Hours Instructions to Candidates:

More information

ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES

ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES (RPB-01) Approved by: Date: SECTION PAGE # 1.0 Scope 2.0 Definitions 3.0 References 4.0 Inspection

More information

Commercial Documentation Wind Turbine Generator Systems Hz and 60 Hz

Commercial Documentation Wind Turbine Generator Systems Hz and 60 Hz GE Energy Commercial Documentation Wind Turbine Generator Systems 2.75-103 - 50 Hz and 60 Hz Product Acoustic Specifications Normal Operation according to IEC 61400-11 imagination at work 2010 GE Company.

More information

Omega Chemicals Emissions Testing Report

Omega Chemicals Emissions Testing Report Omega Chemicals 18-Feb-2015 Doc No. 60336610_1.1_RPT Omega Chemicals Emissions Testing Report February 2015 NATA ACCREDITATION No. 2778 (14391) Accredited for compliance with ISO/IEC 17025 This document

More information

Fabric UDINE. Measurement of sound absorption according to EN ISO 354. Test Report No. M102794/32

Fabric UDINE. Measurement of sound absorption according to EN ISO 354. Test Report No. M102794/32 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de Dipl.-Ing. (FH) Dominik Reif Telephone +49(89)85602 3566 Dominik.Reif@mbbm.com

More information

Page 2 of 14 Report Ref. No

Page 2 of 14 Report Ref. No age 2 of 14 Summary of testing: Tests performed (name of test and test clause): Clause 6.1, Initial measurements: - MST 01: Visual inspection - 10.2: Maximum power determination - MST 16: Dielectric withstand

More information

Test Report. Report Number: L16079 Date: Oct 12, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L16079 Date: Oct 12, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L1679 Date: Oct 12, 216 Issued by: 151 Route 34 South, Farmingdale, NJ 7727 Test of one 2' Gen II Linear Unit manufacturer: Dialight Corporation Unit model number: LTx3B4B2W

More information

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07 Test Report RI Acoustic Lab Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier 20 Feb. 07 Title Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier

More information

Measurement method for the proficiency testing program

Measurement method for the proficiency testing program APLAC T088 Appendix Measurement method for the proficiency testing program Introductions This measurement method is prepared for use by the APLAC Proficiency Testing Program Photometric measurement of

More information

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time We help ideas meet the real world DELTA Test Report DANAK TEST Reg. no. 100 Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time Client: Kvadrat Soft Cells A/S Page 1

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CONTROL COMPANY 12554 Galveston Road Suite B230 Webster, TX 77598 Aaron Judice Phone: 281 482 1714 CALIBRATION Valid To: March 31, 2018

More information

Three Axis Magnetic Field Transducer x-h3x-xx_e3d-2.5khz-1-0.2t

Three Axis Magnetic Field Transducer x-h3x-xx_e3d-2.5khz-1-0.2t DESCRIPTION: TYPICAL APPLICATIONS: The is a high accuracy magnetic flux density-toanalogue-voltage transducer with a highlevel and temperature compensated output signal for each of the three components

More information

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50 IES LM-79-08 MEASUREMENT AND TEST REPORT For ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA 91730 Test Model: HBUF-100W-50 Report Type: Test Engineer: Electrical and Photometric tests

More information

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50 IES LM-79-08 MEASUREMENT AND TEST REPORT For ATG Electronics Corp. 9020 Rancho Park Court Rancho Cucamonga, CA 91730 Test Model: HBUF-150W-50 Report Type: Test Engineer: Electrical and Photometric tests

More information

Fabric TWIST MELANGE Manufacturer Gabriel A/S

Fabric TWIST MELANGE Manufacturer Gabriel A/S Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Dominik Reif Telephone +49(89)85602 3566 Dominik.Reif@mbbm.com

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 11201 Second edition 2010-05-15 Acoustics Noise emitted by machinery and equipment Determination of emission sound pressure levels at a work station and at other specified positions

More information

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and

More information

Fabric Medley Manufacturer Gabriel A/S

Fabric Medley Manufacturer Gabriel A/S Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Dominik Reif Telephone +49(89)85602 3566 Dominik.Reif@mbbm.com

More information

Fabric Corsica. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/16

Fabric Corsica. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/16 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de M. Eng. Philipp Meistring Telephone +49(89)85602 228 Philipp.Meistring@mbbm.com

More information

Series CCR-39S Multi-Throw DC-12 GHz, SP9T & SP10T Latching Coaxial Switch

Series CCR-39S Multi-Throw DC-12 GHz, SP9T & SP10T Latching Coaxial Switch PART NUMBER CCR-39S DESCRIPTION Commercial Latching Multi-throw, DC-12GHz The CCR-39Sis a broadband, multi-throw, electromechanical coaxial switch designed to switch a microwave signal from a common input

More information