Superose High-performance Columns

Size: px
Start display at page:

Download "Superose High-performance Columns"

Transcription

1 GE Healthcare Life Sciences Data file AC Gel filtration Superose High-performance Columns Superose prepacked columns are designed for highperformance, laboratory-scale separations of proteins and other biomolecules according to size. Due to its wide separation range, Superose is a versatile medium. Superose prepacked columns give fast and reproducible separations with good resolution. The columns are ideal for the final polishing step in a purification procedure, where the remaining trace contaminants are removed. Superose columns offer: High-resolution separations of proteins and other biomolecules according to size Wide separation range separations in two molecular weight ranges from 1 up to 5 million M r Excellent reproducibility and durability Laboratory scale purifications, from µg to mg Media characteristics Superose prepacked columns are available with two different media: Superose 6 or Superose 12. Table 1 summarizes the main characteristics of Superose. Good resolution separations of proteins and other biomolecules according to size Gel filtration separates biomolecules according to molecular size. The method is ideal for the final polishing step in a purification procedure when sample volumes have been reduced. Since the composition of the buffer does not Fig 1. Superose 6 GL and Superose 12 GL prepacked Tricorn columns. directly affect the separation, elution conditions such as ph and salt concentration can be varied to suit the sample or the requirements for the next step. A high-performance medium like Superose is invaluable when it is necessary to obtain protein preparations free of dimers and other aggregates, for example before crystallization trials. Superose 6 and Superose 12 have an average bead size of 13 µm and 11 µm respectively, and are designed for laboratory-scale separations. The small bead size gives good resolving capacity. Superose 6 prep grade and Superose 12 prep grade have an average bead size of 3 µm and are suitable for larger scale separations.

2 Table 1. The main characteristics of Superose media Superose 6 Superose 12 Separation range (M r ) 5 to 5 (globular proteins) 1 to 3 (globular proteins) Exclusion limit (M r ) 4 (globular proteins) 2 (globular proteins) Chemical stability Stable in all common buffers: 1 M acetic acid, 8 M urea, 6 M guanidine hydrochloride, 1% SDS, organic solvents,.5 M NaOH (for cleaning-in-place) Stable in all common buffers: 1 M acetic acid, 8 M urea, 6 M guanidine hydrochloride, 1% SDS, organic solvents,.5 M NaOH (for cleaning-in-place) ph stability 3 to 12 (long-term), 1 to 14 (short-term) 3 to 12 (long-term), 1 to 14 (short-term) Temperature stability working storage 4 C to 4 C 4 C to 3 C 4 C to 4 C 4 C to 3 C Matrix Cross-linked agarose Cross-linked agarose Average particle size 13 µm 11 µm Wide separation range separation in two ranges from M r 1 up to M r 5 million Superose 6 and Superose 12 provide good resolution, high selectivity gel filtration separations over a very broad molecular weight range (Superose 6: 5 5 and Superose 12: 1 3 ), as shown in Figure 2. Superose complements Superdex by offering wider molecular weight separation ranges. A comparison between Superose and Superdex is shown in Figure 2. Superose 6 is especially valuable for its ability to separate very large biomolecules according to size. Superdex Peptide Superdex 75 Superdex 2 Superdex 3 prep grade Superdex 75 prep grade Superdex 2 prep grade Superose 6 Superose 12 Superose 6 prep grade Superose 12 prep grade Fig 2. Separation ranges (globular proteins) of Superose and Superdex gel filtration media. High chemical and ph stabilities Superose is formed from cross-linked agarose matrices that have high chemical and broad ph stabilities (short-term ph 1 to 14, long-term ph 3 to 12). Superose media can be used with all common aqueous buffers and are unaffected by detergents such as 1% SDS, chaotropic salts or dissociating agents such as 8 M urea or 6 M guanidine hydrochloride, and organic solvents such as 3% acetonitrile. The media can withstand strong bases (such as.2 M NaOH) and strong acids (such as 1 M acetic acid or 7% formic acid) allowing the use of stringent cleaning procedures, which are essential to maintain column efficiency without reducing the lifetime of the column. Column characteristics Superose media are prepacked in high performance glass columns. Both column types Tricorn (GL) and Precision (PC) are made of glass, which allows visual inspection of the gel bed. All parts of the columns are biocompatible. Table 2 shows the characteristics of Tricorn and Precision columns prepacked with Superose. Tricorn columns are simple to use, with fittings for simple connection to ÄKTAdesign and other high-performance LC systems, and can be run according to their specifications where the systems have the appropriate pressure capacity. Precision Columns were designed for SMART systems, but the Precision Column Holder allows use of the columns with a variety of high-performance systems. All parts of the columns are biocompatible AC

3 Table 2. Characteristics of Tricorn and Precision columns prepacked with Superose Superose 6 1/3 GL columns Tricorn Columns Superose 12 1/3 GL columns Superose 6 PC 3.2/3 columns Precision Columns Superose 12 PC 3.2/3 columns Bed dimensions (i.d. height mm) Bed volume (ml) Recommended sample volume (μl)* Theoretical Plates (m -1 ) > 3 > 4 > 3 > 4 Recommended flow rate (ml/min)* Max. flow rate (ml/min)** Max. pressure over column 15 bar 3 bar 12 bar 24 bar (217 psi, 1.5 MPa) (435 psi, 3 MPa) (174 psi, 1.2 MPa) (348 psi, 2.4 MPa) * In general, a lower sample volume gives a higher resolution. ** (H 2 O at 25 C). Excellent reproducibility and durability Reproducible results are essential in all research. The long working life and high reproducibility of Superose prepacked columns, both run-to-run and column-to-column, are a result of optimized column design, the stable nature of Superose, and well-proven, reliable column packing procedures. These are in addition to the controlled column manufacturing and media synthesis, and strict quality control testing of every production batch of Superose and each prepacked column. Figure 3 shows the separation of protein standards on Superose 12 1/3 GL before and after 21 consecutive runs. Operation Choice of eluents Eluents can be chosen freely to improve recovery from separations of crude sample or to overcome solubility problems. For example, chaotropic agents and detergents can be used to improve the solubility of membrane proteins..15 M NaCl, or a buffer with equivalent ionic strength, is recommended to avoid ph-dependent non-ionic interactions with the matrix. Sample volumes The quality of a gel filtration separation is largely independent of sample concentration, but to achieve good resolution, the sample volume should be less than 5% of the total column volume. Sample volumes between.1% and 1.% of the bed volume (25 to 25 µl) give the highest resolution in Superose 1/3 GL columns. For more information see Table 2. Column: Sample: Sample volume: 5 µl A 28 mau A 28 mau Superose 12 1/3 GL 1. IgG (M r 15 ) 2.5 mg/ml, 2. BSA (M r 67 ) 8 mg/ml, 3. β-lactoglobulin (M r 35 ) 2.5 mg/ml, 4. Cytochrome C (M r 12 7) 1 mg/ml, 5. Vitamin B 12 (M r 1355).3 mg/ml Eluent:.15 M NaCl +.5 M phosphate ph 7. Flow rate: System: Detection:.5 ml/min ÄKTAFPLC A 28 nm Test separation, run ml Test separation, run ml Fig 3. Comparison of the test separation runs 1 and 21 after repeated injection of a test sample on Superose 12 1/3 GL. No difference in chromatographic performance is observed after 21 runs AC 3

4 Large-scale preparative separation To handle larger sample volumes it may be necessary to pack larger columns. Superose 6 prep grade and Superose 12 prep grade are available in lab packs for use when larger column volumes are required. Superose prep grade media have an increased bead size to give a similar selectivity to prepacked Superose columns, but easier column packing and tolerance to crude samples. Figure 4 shows selectivity curves for Superose prep grade (3 µm), compared to Superose 6 (13 µm) and Superose 12 (1 µm). K av Superose 12 Superose 6 prep grade Superose 6 Superose 12 prep grade Mr Fig 4. Selectivity curves for Superose 6 and 12, and Superose 6 and 12 prep grade (globular proteins). Applications Separation of standard proteins Superose 6 1/3 GL and Superose 12 1/3 GL are prepacked columns produced under optimum conditions to give the highest column efficiency and performance. These columns offer good resolution and broad selectivity gel filtration over a broad molecular weight range, as shown in Figure 5. A Column: Superose 6 1/3 GL Sample: Proteins from Gel Filtration Calibration Kits LMW and HMW (GE Healthcare) T = thyroglobulin (M r 669 ) F = ferritin (M r 44 ) Ald = aldolase (M r 158 ) O = ovalbumin (M r 43 ) CA = carbonic anhydrase (M r 29 ) R = RNase A (M r 13 7) Apr = aprotinin (M r 6 5) Sample volume: 1 µl Eluent:.5 M Phosphate,.15 M NaCl, ph 7.2 Flow rate:.5 ml/min System: ÄKTAexplorer 1 Detection: 28 nm ml mau B mau F Ald T O CA ml F O Ald R Apr CA R Apr Log M r K av K av Aprotinin RNase A Aprotinin RNase A Carb. anh Column: Superose 12 1/3 GL Sample: Proteins from Gel Filtration Calibration Kits LMW and HMW (GE Healthcare) F = ferritin (M r 44 ) Ald = aldolase (M r 158 ) O = ovalbumin (M r 43 ) CA = carbonic anhydrase (M r 29 ) R = RNase A (M r 13 7) Apr = aprotinin (M r 6 5)) Sample volume: 1 µl Eluent:.5 M Phosphate,.15 M NaCl, ph 7.2 Flow rate:.5 ml/min System: ÄKTAexplorer 1 Detection: 28 nm Ovalb Carb. anh Ovalb Aldolase Aldolase Ferritin Thyrogl Ferritin Log M r Fig 5. (A) Standard proteins separated on Superose 6 1/3 GL, molecular weight range: 5 5 and calibration curve. (B) Standard proteins separated on Superose 12 1/3 GL, molecular weight range: 1 3 and calibration curve AC

5 Micropurification of human tears Figure 6 shows an example of the extremely small amounts of sample that can be analyzed on a Superose PC column. A 28nm A A 254 nm Column: 2 Superose 6 high performance columns 1 3 mm (i.d. bed height) Sample: 1 µg Hae III, cleared pbr 322 Eluent:.5 M Tris-HCI, 1 mm EDTA, ph 8 Flow:.1 ml/min Time (min) Fig 6. Micropurification of.75 µl of human tears using Superose 12 PC3.2/3 column on a SMART system. Separation of DNA fragments Figure 7 shows examples of separations performed using a Superose prepacked high-performance column for the separation of DNA fragments. In Figure 7a, two columns have been linked in series to increase resolution Time (h) B A 254 nm Column: Superose 6 high performance column 1 3 mm (i.d. bed height) Sample: φx-174 Rf DNA, Hae III digested, 1 µg Eluent:.5 M Tris, ph 8 Flow:.4 ml/min Time (min) Fig 7. Two examples of separation of DNA fragments on a Superose high-performance column, 1 3 mm (inner diameter bed height). Peak figures correspond to number of base pairs AC 5

6 Ordering information Product Quantity Code No. Superose 6 1/3 GL Superose 6 PC 3.2/ Superose 12 1/3 GL Superose 12 PC 3.2/ Related products Gel Filtration Calibration kit HMW Gel Filtration Calibration kit LMW Precision Column Holder Literature Tricorn Empty High Performance Columns, Data file Superdex High-performance columns, Data file Gel Filtration Handbook Strategies for Protein Purification Handbook Recombinant Protein Purification Handbook Prepacked chromatography columns for ÄKTA design systems, Selection guide Gel Filtration Selection Guide For local office contact information, visit GE Healthcare Bio-Sciences AB Björkgatan Uppsala Sweden imagination at work GE, imagination at work, and GE monogram are trademarks of General Electric Company. ÄKTAdesign, ÄKTAexplorer, ÄKTAFPLC, Superose, Superdex, and Tricorn are trademarks of GE Healthcare companies. All third party trademarks are the property of their respective owners. The Tricorn column and components are protected by US design patents USD5856, USD56261, USD5555, USD4956 and their equivalents in other countries General Electric Company All rights reserved. First published Nov. 22 All goods and services are sold subject to the terms and conditions of sale of the company within GE Healthcare which supplies them. A copy of these terms and conditions is available on request. Contact your local GE Healthcare representative for the most current information. GE Healthcare UK Limited Amersham Place Little Chalfont Buckinghamshire, HP7 9NA UK GE Healthcare Europe, GmbH Munzinger Strasse 5 D Freiburg Germany GE Healthcare Bio-Sciences Corp. 8 Centennial Avenue, P.O. Box 1327 Piscataway, NJ USA GE Healthcare Japan Corporation Sanken Bldg., , Hyakunincho Shinjuku-ku, Tokyo Japan AC 3/211

HiTrap HIC Selection Kit

HiTrap HIC Selection Kit GE Healthcare Data File 18-1143-21 AC Hydrophobic interaction chromatography HiTrap HIC Selection Kit Introduction The HiTrap HIC Selection Kit consists of seven hydrophobic interaction chromatography

More information

Mag Sepharose is available in the following formats (Instructions for use are included): μl TiO 2

Mag Sepharose is available in the following formats (Instructions for use are included): μl TiO 2 GE Healthcare Instructions 28-9537-65 AB Mag Sepharose Mag Sepharose Mag Sepharose is available in the following formats (Instructions for use are included): 1 500 μl Mag Sepharose, 20% medium slurry 4

More information

CM Sepharose Fast Flow DEAE Sepharose Fast Flow SP Sepharose Fast Flow

CM Sepharose Fast Flow DEAE Sepharose Fast Flow SP Sepharose Fast Flow Instructions 7-5009-64 AF Ion exchange media CM Sepharose Fast Flow DEAE Sepharose Fast Flow Q Sepharose Fast Flow SP Sepharose Fast Flow CM, DEAE, Q and SP Sepharose Fast Flow ion exchangers are part

More information

Evaluation of the performance of Amersham HyPer5 dye in comparative genomic hybridization microarray applications

Evaluation of the performance of Amersham HyPer5 dye in comparative genomic hybridization microarray applications GE Healthcare Application note 28-9304-76 AA Nucleic acid labeling and detection Evaluation of the performance of Amersham HyPer5 dye in comparative genomic hybridization microarray applications Key words:

More information

MicroCal itc 200. System MicroCal Auto-iTC 200. System. GE Healthcare Life Sciences. System design and description. provide:

MicroCal itc 200. System MicroCal Auto-iTC 200. System. GE Healthcare Life Sciences. System design and description. provide: GE Healthcare Life Sciences Data file 28-97822 AC MicroCal label-free interaction analysis MicroCal itc 2 System MicroCal Auto-iTC 2 System MicroCal itc 2 and MicroCal Auto-iTC 2 isothermal titration calorimetry

More information

PreDictor 96-well filter plates and Assist software

PreDictor 96-well filter plates and Assist software GE Healthcare Life Sciences Data file 28-9258-39 AF High-throughput process development PreDictor 96-well filter plates and Assist software PreDictor 96-well filter plates (Fig 1) are prefilled with GE

More information

Amersham CyDye fluors

Amersham CyDye fluors GE Healthcare Life Sciences Amersham CyDye fluors Selection Guide Welcome to Amersham CyDye fluors Amersham CyDye fluors are versatile fluorophores designed for a broad range of applications. CyDye fluors

More information

PreDictor 96-well filter plates and Assist software

PreDictor 96-well filter plates and Assist software GE Healthcare Life Sciences Data file 28-9258-39 AG High-throughput process development PreDictor 96-well filter plates and Assist software PreDictor 96-well filter plates (Fig 1) are prefilled with GE

More information

Cellufine Butyl Cellufine Phenyl

Cellufine Butyl Cellufine Phenyl Hydrophobic Interaction Chromatography Media Cellufine Butyl Cellufine Phenyl Technical Data Sheet 2-1, Otemachi 2-Chome Chiyoda-ku, Tokyo 100-8105 JAPAN Phone +81-3-3243-6150 Fax +81-3-3243-6219 e-mail:

More information

Cellufine Butyl Cellufine Phenyl

Cellufine Butyl Cellufine Phenyl Hydrophobic Interaction Chromatography Media Cellufine Butyl Cellufine Phenyl Technical Data Sheet Introduction For purification of proteins and macromolecules Hydrophobic Interaction Chromatography (HIC)

More information

ProPac WCX-10 Columns

ProPac WCX-10 Columns ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,

More information

Applications and Properties of New Polymeric Mixed Mode Cation Exchange Chromatography Media

Applications and Properties of New Polymeric Mixed Mode Cation Exchange Chromatography Media Applications and Properties of New Polymeric Mixed Mode Cation Exchange Chromatography Media Nandu Deorkar*, Wei Guo, Bob Buss, Joe Mladosich and Paul Bouis Mallinckrodt Baker Inc. 1904 J.T. Baker Way

More information

Sepax SRT -C, Zenix -C SEC Phases

Sepax SRT -C, Zenix -C SEC Phases Sepax SRT -C, Zenix -C SEC Phases Complimentary Phases to SRT for Derivatized Monoclonal Antibodies General Description Stationary Phase Structure SRT, Zenix, SRT-C and Zenix-C SEC phases developed based

More information

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography Sepax Technologies, Inc. Preparative Size Exclusion Chromatography SRT -0/0C (0 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC Better Surface Chemistry for Better Separation SRT -0/0C Size Exclusion

More information

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How?

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How? Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How? Jean Lane Applications Engineer LC Columns & Consumables Technical Support January 19, 2017 What we will cover What - Clarification of the

More information

Covalent coupling procedures for Sera Mag and Sera-Mag SpeedBeads Carboxylate-Modified Magnetic Particles

Covalent coupling procedures for Sera Mag and Sera-Mag SpeedBeads Carboxylate-Modified Magnetic Particles GE Healthcare Covalent coupling procedures for Sera Mag and Sera-Mag SpeedBeads Carboxylate-Modified Magnetic Particles Sera-Mag and Sera-Mag SpeedBeads provide a costeffective magnetic bead separation

More information

HPLC Column Material - Bulk Ware

HPLC Column Material - Bulk Ware HPLC Column Material - Bulk Ware Constantly growing demands on separation efficiency and availability of solid phase material for packing HPLC columns and column packing stations have motivated us to provide

More information

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page No.106 Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series Contents Page 1. Introduction 2. Features 3. Basic characteristics 3-1. Pore characteristics 3-2. Sample injection volume

More information

Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis

Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis Comparing Columns from Different Vendors to Improve Data Quality Technical Overview Introduction Size exclusion chromatography

More information

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE Introduction Gel permeation chromatography (GPC) and size exclusion chromatography

More information

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis Application Note AN89.V.1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Page 1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Prior to LC-MS/MS Analysis Sample Preparation

More information

GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series. Contents

GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series. Contents No.038 GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series Contents Page 1. Introduction 2. Calibration curves, theoretical plate numbers and separation range

More information

Non-Interfering Protein Assay Kit Cat. No

Non-Interfering Protein Assay Kit Cat. No Visit our interactive pathways at /pathways User Protocol 488250 Rev. 5 January 2006 RFH Page 1 of 1 Non-Interfering Protein Assay Kit Cat. No. 488250 Note that this user protocol is not lot-specific and

More information

TrioMol Isolation Reagent

TrioMol Isolation Reagent TrioMol Isolation Reagent Technical Manual No. 0242 Version 06142007 I Description... 1 II Key Features... 1 III Storage..... 1 IV General Protocol Using Triomol Isolation Reagent 1 V Troubleshooting.

More information

TrioMol Isolation Reagent

TrioMol Isolation Reagent TrioMol Isolation Reagent Technical Manual No. 0242 Version 06142007 I Description... 1 II Key Features... 1 III Storage..... 1 IV General Protocol Using Triomol Isolation Reagent 1 V Troubleshooting.

More information

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis [ viridis columns ] viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC)

More information

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography Biologics Workflow AGGREGATE ANALYSIS by Size Exclusion Chromatography New biozen SEC columns provide: High efficiency on both HPLC and UHPLC Extreme inertness and robustness Finely tuned high and low

More information

Thiopropyl Sepharose 6B

Thiopropyl Sepharose 6B Thiopropyl epharose 6B INTRUCTION Thiopropyl epharose 6B contains reactive 2-thiopyridyl disulphide groups attached to epharose through a chemically stable ether linkage, see fig. 1. Matrix O CH 2 CH CH

More information

Basic Principles for Purification Using Supercritical Fluid Chromatography

Basic Principles for Purification Using Supercritical Fluid Chromatography Basic Principles for Purification Using Supercritical Fluid Chromatography Jo-Ann M. Jablonski, Christopher J. Hudalla, Kenneth J. Fountain, Steven M. Collier, and Damian Morrison Waters Corporation, Milford,

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Thermo Scientific Accucore XL HPLC Columns. Technical Manual Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users

More information

Technical data and operating instructions. Vivaspin 4. Vivaspin 4 10K device for in vitro diagnostic use

Technical data and operating instructions. Vivaspin 4. Vivaspin 4 10K device for in vitro diagnostic use Technical data and operating instructions Vivaspin 4 Vivaspin 4 10K device for in vitro diagnostic use 85030-516-16 85030-516-16 Vivaspin 4 ml Introduction Storage conditions shelf life Vivaspin 4 ultrafiltration

More information

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience. Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience. Pure Consumables More focus on your application The Pure consumable portfolio offers an unrivaled range of products

More information

ACQUITY UPLC Peptide BEH C 18, 130Å and 300Å Columns

ACQUITY UPLC Peptide BEH C 18, 130Å and 300Å Columns CONTENTS I. INTRODUCTION II. III. GETTING STARTED a. Column Connectors b. Column Installation c. Column Equilibration d. ecord Installation e. Initial Column Efficiency Determination COLUMN USE a. Sample

More information

Method Development with ZirChrom's Ion Exchange Phases

Method Development with ZirChrom's Ion Exchange Phases For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than

More information

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC LC800 Smart HPLC Until now UHPLC From now Smart HPLC Smart HPLC Leads to Ultimate Performance Patent Pending S LC800 is a completely new and unique concept, designed for maximum performance in high resolution

More information

Amersham Cy3/HyPer5 reactive dye protocols for post labeling amino allyl-cdna and amino allyl-arna

Amersham Cy3/HyPer5 reactive dye protocols for post labeling amino allyl-cdna and amino allyl-arna GE Healthcare Amersham Cy3/HyPer5 reactive dye protocols for post labeling amino allyl-cdna and amino allyl-arna For microarray applications Product booklet Codes: 28-9224-18 28-9224-19 Page finder 1.

More information

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC USP Method Transfer and Routine Use Analysis of Tablets from HPLC to UPLC Aparna Chavali, Tanya Jenkins and Patricia McConville Waters Corporation, 34 Maple Street, Milford, MA USA APPLICATION BENEFITS

More information

Protein separation and characterization

Protein separation and characterization Address:800 S Wineville Avenue, Ontario, CA 91761,USA Website:www.aladdin-e.com Email USA: tech@aladdin-e.com Email EU: eutech@aladdin-e.com Email Asia Pacific: cntech@aladdin-e.com Protein separation

More information

TaKaRa BCA Protein Assay Kit

TaKaRa BCA Protein Assay Kit Cat. # T9300A For Research Use TaKaRa BCA Protein Assay Kit Product Manual Table of Contents I. Description... 3 II. Components... 3 III. Storage... 3 IV. Materials Required by not Provided... 3 V. Precautions

More information

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma Jon Bardsley 1, James Goldberg 2 1 Thermo Fisher Scientific, Runcorn, UK; 2 Thermo Fisher Scientific, West Palm Beach,

More information

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials

More information

E.Z.N.A. MicroElute Clean-up Kits Table of Contents

E.Z.N.A. MicroElute Clean-up Kits Table of Contents E.Z.N.A. MicroElute Clean-up Kits Table of Contents Introduction... 2 Kit Contents... 3 Preparing Reagents/Storage and Stability... 4 Guideline for Vacuum Manifold... 5 MicroElute Cycle-Pure - Spin Protocol...

More information

Dionex IonPac AS28-Fast-4µm column

Dionex IonPac AS28-Fast-4µm column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS-Fast-4µm Columns Product Specifications The Thermo Scientific Dionex IonPac AS-Fast-4µm column is a high-capacity, hydroxide-selective anionexchange column

More information

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 021 MOD: 1st Issue Page: 1 of 6

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 021 MOD: 1st Issue Page: 1 of 6 Page: 1 of 6 1. Risk Assessment: This Risk Assessment is to be used as a general guide and as such, cannot accommodate all the varying factors that may be encountered when using this equipment. Therefore,

More information

Phenol-Chloroform reagents. Selection guide. OH ; MW : High quality reagents for use in nucleic acid purification.

Phenol-Chloroform reagents. Selection guide. OH ; MW : High quality reagents for use in nucleic acid purification. Phenol-Chloroform reagents Extraction with phenol and phenol/chloroform mixtures is a universal method for purification of DNA and RNA. Proteins and restriction enzymes are removed by phenol and chloroform

More information

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens

More information

HPLC Columns. HILICpak VT-50 2D MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia

HPLC Columns. HILICpak VT-50 2D MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia HPLC Columns MANUAL HILICpak VT-50 2D Shodex HPLC Columns Europe, Middle East, Africa, Russia For technical support please use contact details shown below: SHOWA DENKO EUROPE GmbH Shodex Business Konrad-Zuse-Platz

More information

Peptide Isolation Using the Prep 150 LC System

Peptide Isolation Using the Prep 150 LC System Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The Prep 150 LC System, an affordable, highly reliable system for preparative chromatography, is suitable

More information

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples Technical Note 101 Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples This technical note includes by specific information on the extraction

More information

The Challenge: Sepax SEC C-line columns!

The Challenge: Sepax SEC C-line columns! The Challenge: Are you working with a sample that shows a tendency to stick to traditional size exclusion resins with delayed elution time, low recovery, varying HMWS, or excessive tailing? Sepax SEC C-line

More information

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis Application Note AN785 Extraction of Aflatoxins and chratoxin From Dried Chili Using ISLUTE Myco prior to LC-MS/MS Analysis Page Extraction of Aflatoxins and chratoxin from Dried Chili Using ISLUTE Myco

More information

Impact of Pore Exclusion on Reversed-Phase HPLC Column Performance

Impact of Pore Exclusion on Reversed-Phase HPLC Column Performance Impact of Pore Exclusion on Reversed-Phase HPLC Column Performance Richard A. Henry, Technical Consultant, 983 Greenbriar Drive, State College, PA 16801 (hyperlc@comcast.net) Stephanie Schuster, AMT, Inc.,

More information

[ Care and Use Manual ]

[ Care and Use Manual ] Oasis HLB DISKS I. Introduction Oasis HLB is a Hydrophilic-Lipophilic-Balanced, water-wettable, reversed-phase sorbent for all your SPE needs. It is made from a specific ratio of two monomers, the hydrophilic

More information

ACQUITY UPLC HSS Columns

ACQUITY UPLC HSS Columns CONTENTS I. INTRODUCTION II. II. GETTING STARTED a. Column Connectors b. Column Installation c. Column Equilibration d. ecord Installation e. Initial Column Efficiency Determination f. VanGuard Pre-columns

More information

CAPCELL PAK C18 IF2 Type http://hplc.shiseido.co.jp/e/column/html/if2_index.htm Page 1 of 2 List of Sales Representatives Contact Shiseido Technical Materials Catalog List HPLC Columns HPLC Instruments

More information

The power of multi-detector SEC in the analysis of antibodies

The power of multi-detector SEC in the analysis of antibodies The power of multi-detector SEC in the analysis of antibodies How OMNISEC can measure antibody absolute MW independent of size and structural changes MOLECULAR SIZE MOLECULAR STRUCTURE MOLECULAR WEIGHT

More information

AMBERLITE HPR1300 H Ion Exchange Resin

AMBERLITE HPR1300 H Ion Exchange Resin Product Data Sheet AMBERLITE HPR1300 H Ion Exchange Resin Uniform Particle Size, Gel, Strong Acid Cation Exchange Resin for Condensate Polishing in the Power Industry and Industrial Demineralization Applications

More information

GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI

GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI syringe filters promises reproducible results from the filtration of organic and aqueous solutions in HPLC. Trace amount of samples containing impurities or contaminants can be easily removed, resulting

More information

Improve HPLC Separations by Carefully Matching Column Pore-Size to Solute-Size

Improve HPLC Separations by Carefully Matching Column Pore-Size to Solute-Size Improve HPLC Separations by Carefully Matching Column Pore-Size to Solute-Size Richard A. Henry, Consultant 983 Greenbriar Drive State College, PA 16801 HyperLC@comcast.net Stephanie A. Schuster, Sr. Chemist

More information

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION Andrew J. Aubin and Tanya L. Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION Benzocaine (4-Aminobenzoic

More information

Gemini-NX Performance paired with Axia Technology

Gemini-NX Performance paired with Axia Technology Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While

More information

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS EAS 2005 Bingwen Yan 1, Clayton V. McNeff 1, Richard A. Henry 2, and David S. Bell 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka,

More information

ActiPix SDI300 Surface Dissolution Imaging System

ActiPix SDI300 Surface Dissolution Imaging System Product Note: PN002B Figure 1. SDI300 Surface Dissolution Imaging System Introduction The ActiPix SDI300 is a powerful UV area imaging system which enables quantitative imaging of surface phenomena for

More information

Optical Isomer Separation Columns and Packing Materials

Optical Isomer Separation Columns and Packing Materials 02 Optical Isomer Separation s and Packing Materials CHIRAL ART----------------------------------- 26~29 YMC CHIRAL NEA (R), (S)-----------------------30 YMC CHIRAL CD BR------------------------------31

More information

Biochemistry. Biochemical Techniques HPLC

Biochemistry. Biochemical Techniques HPLC Description of Module Subject Name Paper Name 12 Module Name/Title 13 1. Objectives 1.1. To understand the basic concept and principle of 1.2. To understand the components and techniques of 1.3. To know

More information

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry APPLICATION NOTE Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry AN43227 Antonella Guzzonato 1, Shona McSheehy Ducos

More information

Lecture 26: More on Gel Filtration Chromatography and the Trypsin Resurrection Experiment

Lecture 26: More on Gel Filtration Chromatography and the Trypsin Resurrection Experiment Biological Chemistry Laboratory Biology 3515/Chemistry 3515 Spring 2018 Lecture 26: More on Gel Filtration Chromatography and the Trypsin Resurrection Experiment 12 April 2018 c David P. Goldenberg University

More information

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction Peptide Purification Method Development: Application for the Purification of Bivalirudin Marc Jacob, Joshua Heng, and Tivadar Farkas Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA In this technical

More information

PHYCOLINK CONJUGATE EVALUATIONS

PHYCOLINK CONJUGATE EVALUATIONS TechNote #TNPJ200 PHYCOLINK CONJUGATE EVALUATIONS INTRODUCTION PhycoLink Conjugation Kits provide a quick and simple method to attach fluorescent pigments to antibodies or other proteins of interest. When

More information

[ CARE AND USE MANUAL ]

[ CARE AND USE MANUAL ] CONTENTS I. INTRODUCTION II. III. IV. GETTING STARTED a. Column Installation b. Column Equilibration c. Initial Column Efficiency Determination COLUMN USE a. Guard Columns b. Sample Preparation c. ph Range

More information

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent

More information

Determination of trace anions in concentrated hydrofluoric acid

Determination of trace anions in concentrated hydrofluoric acid APPLICATION NOTE 78 Determination of trace anions in concentrated hydrofluoric acid Authors Archava Siriraks Thermo Fisher Scientific, Sunnyvale, CA Keywords HF, ICS-5000 +, IonPac AS10, IonPac AC10, ion

More information

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns Application Note 3 Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns INTRODUCTION Polymeric monolithic stationary phases offer an alternative to the classical microparticulate

More information

IRDye 800CW Protein Labeling Kit Low MW

IRDye 800CW Protein Labeling Kit Low MW IRDye 800CW Protein Labeling Kit Low MW Developed for: Aerius, and Odyssey Family of Imagers Please refer to your manual to confirm that this protocol is appropriate for the applications compatible with

More information

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Determination of Trace Cations in Power Plant Waters Containing Morpholine Application Note 8 Determination of Trace Cations in Power Plant Waters Containing Morpholine INTRODUCTION Morpholine and ammonium are used as additives in power plant waters. Morpholine acts as a corrosion

More information

Functional Genomics Research Stream. Lecture: February 17, 2009 Masses, Volumes, Solutions & Dilutions

Functional Genomics Research Stream. Lecture: February 17, 2009 Masses, Volumes, Solutions & Dilutions Functional Genomics Research Stream Lecture: February 17, 2009 Masses, Volumes, Solutions & Dilutions Agenda Lab Work: Last Week New Equipment Solution Preparation: Fundamentals Solution Preparation: How

More information

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection APPLICATION NOTE 72686 Determination of underivatized aflatoxins,, G2, and in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection Authors Sylvia Grosse, Mauro De Pra, Frank

More information

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples TN143 EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples This Chemistry Data Sheet provides guidelines for the extraction of quaternary

More information

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide Supported Liquid Extraction (SLE) Guide and FAQ s User Guide What is SLE? Supported Liquid Extraction (SLE) is an extraction technique that separates out compounds based on their affinity for one solvent

More information

U.S. Patent No. 9,051,563 and other pending patents. Ver

U.S. Patent No. 9,051,563 and other pending patents. Ver INSTRUCTION MANUAL Direct-zol 96 RNA Catalog Nos. R2054, R2055, R2056 & R2057 Highlights Quick, 96-well purification of high-quality (DNA-free) total RNA directly from TRIzol, TRI Reagent and all other

More information

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This

More information

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity Janet Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS High

More information

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time Thermo Scientific Syncronis HPLC Columns Remarkable separations guaranteed time after time Syncronis HPLC and UHPLC Columns Remarkable separations guaranteed time after time When developing a new method,

More information

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties AN HPLC COLUMN TM InertSustain C8 AN HPLC COLUMN InertSustain TM C8 Inertsil continues to evolve to InertSustain Physical Properties Silica : Newly Developed Silica Gel Particle Size : m, m, m Surface

More information

Stationary phases for prep LC

Stationary phases for prep LC The Selectivity Company Versatile hybrid silica-based Stationary phases for prep LC YMC-Triart Prep Stability Reliability ph stable www.ymc.de 2 Contents 3 page Introduction...4-8 How to Make the Correct

More information

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis Keywords: Automated GX-271 GPC Clean-up System, Contaminants,

More information

Definitive EtG/EtS LC-MS/MS Analysis:

Definitive EtG/EtS LC-MS/MS Analysis: Definitive / LC- Analysis: A Rugged 4-Min Method for High-Throughput Labs By Justin Steimling and Frances Carroll Abstract Methods for monitoring alcohol consumption biomarkers and are generally limited

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk

More information

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1

More information

TSKgel Size Exclusion Chromatography Columns

TSKgel Size Exclusion Chromatography Columns Silica-based for protein analysis: TSKgel SW mab TSKgel SW TSKgel SWXL TSKgel SuperSW Polymer-based for desalting: TSKgel BioAssist DS Columns Polymethacrylate-based for water-soluble polymers analysis:

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

columns IonPac SCS 1 Silica Cation Separator

columns IonPac SCS 1 Silica Cation Separator columns IonPac SCS Silica Cation Separator The SCS Silica Cation Separator is designed for use with nonsuppressed conductivity detection, or single-column ion chromatography (SCIC). This column is particularly

More information

Bringing uhplc Performance to the Separation of Peptides

Bringing uhplc Performance to the Separation of Peptides P e p t i d e E S - C 1 8 U H P L C C o l u m n s Bringing uhplc Performance to the Separation of Peptides Compatible with UHPLC and conventional HPLC equipment. Sumpfstr. 3, CH-6300 Zug; Fax: 041 748

More information

Chiral separations efficient, fast and productive

Chiral separations efficient, fast and productive Chiral separations efficient, fast and productive By Per Jageland*, Mattias Bengtsson and Kristina Hallman AkzoNobel Eka Chemicals AB, Separation Products SE 445 80 Bohus Sweden Introduction Chromatographic

More information

anion-exchange column

anion-exchange column columnsionpac ASA Anion-Exchange Column The IonPac ASA is a carbonateselective anion-exchange column designed for the fast separation of inorganic anions, including fluoride, chlorite, bromate, chloride,

More information

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1

More information

Guide to Choosing and Using Polymer Reversed Phase Columns!

Guide to Choosing and Using Polymer Reversed Phase Columns! Guide to Choosing and Using Polymer Reversed Phase Columns! Choosing the best RP Column to use: Silica is normally used as the packing material for HPLC columns for a number of reasons. It is very strong,

More information

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR CONFOCHECK Infrared Protein Analysis Innovation with Integrity FT-IR CONFOCHECK: FT-IR System for Protein Analytics FT-IR Protein Analysis Infrared spectroscopy measures molecular vibrations due to the

More information