1 009 International Nuclear Atlantic Conference - INAC 009 Rio de Janeiro, RJ, Brazil, September7 to October, 009 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: STRONTIUM ISOTOPES AS NATURAL TRACERS IN RESERVOIR OILFIELD AND IN GROUNDWATER SYSTEMS Marcos E. Santos, Helena E. L. Palmieri and Rubens M. Moreira Centro de Desenvolvimento da Tecnologia Nuclear, CDTN/CNEN Avenida Presidente Antônio Carlos, Belo Horizonte, MG mes@cdtn.br; help@cdtn.br; rubens@cdtn.br ABSTRACT The radioactive beta (ß - ) decay of 87 Rb to 87 is an important isotope system that has been widely applied for geochronological purposes and in identifying ground water sources, aquifer interactions and as a tracer for a secondary recovery process in offshore oilfields via seawater injection. The 87 / 86 ratio of present seawater is constant worldwide, while formation waters in hydrocarbon reservoirs have various values are in most cases higher than modern seawater. This can be the basis for a natural tracer technique aiming at evaluating the performance of seawater injection processes by evaluating the 87 / 86 ratio and the total content of formation waters in the reservoir prior to injection, followed by monitoring these values in the produced water as injection proceeds. Inductively Couple Plasma Mass Spectrometry ICP-MS is a technique that has potential to be used in studies with tracers in the environment in the determination of isotope ratios and element traces in a sample. This work describes the methodology that will be used for the determination of variations in the isotopic composition of and presents the preliminary results obtained determination of the strontium isotope ratios ( 87 / 86 ) using Inductively Coupled Plasma Mass Spectrometry (ICP-MS).. INTRODUCTION The element strontium (atomic number 8) has four stable isotopes with mass numbers 84, 86, 87, and 88. For most elements, the isotopic composition is constant in nature. However, this is not the case with strontium. A steady increase in the 87 / 86 ratio over long time spans is observed, due to the radioactive decay of 87 Rb (half-life of 48,8 x 0 9 years) to 87. The radioactive beta (ß - ) decay of 87 Rb to 87 is an important isotope system that has been extensively applied for geochronological purposes. More important it is extensively used to determine rates and fluxes involved in a wide range of geological processes operating from within the hydrosphere of the soil/rock system to the deep mantle. In addition, recently strontium isotopes have increasingly been applied as tracers for defining provenances in many different scientific disciplines (biology, nutrition, medicine, forensic and art history) []. Strontium isotopic composition is also an important tool in hydrogeology, enabling tracing of ground-water flow and water mixing []. In oilfields the natural production mechanism, or primary production, contributes to the extraction of about 5% of the original oil from the reservoirs. This means that over 75% of the originally existing oil remains in the pores and fissures of the oil bearing rocks. The production flow rate depends on the differential pressure between the permeable layer and the bottom of the well, the average permeability, the layer thickness and the oil viscosity. The

2 main natural production mechanism are the expansion of oil, water and gas and in certain cases the water influx from aquifers connected with the reservoir oilfields []. When primary oil production decreases inside a reservoir due to the reduction of the original pressure, water is usually injected to increase the oil production anew. Water injected into special wells (injection wells) forces the oil remaining in certain layers to emerge at other wells (production wells) close to the injector. This technique, commonly called secondary recovery, contributes to the extraction of up to 50% of the original oil in reservoirs. The injected fluid may be spiked with a tracer for the purpose of assessing the efficiency of the secondary oil recovery process. Samples taken at production wells are then analyzed for the tracer, the results yielding important information; the breakthrough of the injection fluid at the production well sampled can thus be detected. Presently used tracers usually fall into one of two categories, chemical (including fluorescent dyes) or radioactive. However, such tracers may be subject to several limitations [4], especially when working in crowded offshore platforms. Besides this, in many applications multiple tracers may be required. This is where the search for novel tracers comes in. The 87 / 86 ratio of oilfield formation waters is significantly higher than that of seawater, in so far as the former have stay in contact with the reservoir rocks for extended periods of time. Strontium is relatively abundant in seawater (~8 ppm). Numerous measurements of 87 / 86 in ocean water have demonstrated that this ratio is constant throughout oceans worldwide at ~ (relative to a value of for the NBS 987 standard). In contrast to seawater, oilfield waters show rather variable isotope contents (< >0.70) [4]. The aim of this work is to develop a methodology for the determination of the 87 / 86 ratio using inductively coupled plasma mass spectrometry (ICP-MS). This ratio will be used as the natural tracer for seawater injection, as well as a tracer of groundwater flow and mixing.. EXPERIMENTAL.. Instrumentation Traditionally, thermal ionization magnetic sector mass spectrometry (TIMS) is the method of choice for measuring the isotope ratio, because most commonly used applications, such as in geochronology, require a precision of better than 0.0% relative standard deviation (RSD) of the 87 / 86 ratio. In comparison with TIMS, the precision that can be obtained with quadrupole-based ICP-mass spectrometry (ICP-QMS) is relatively poor ( 0.% RSD). However, for applications for which the ultimate level of precision is not required, ICP-QMS is an attractive alternative to TIMS, owing to its ease of operation, widespread availability of instruments, and much higher sample throughput [5]. As in ICP-MS, sample preparation for TIMS is laborious and requires chemical isolation of the strontium since the 87 signal is corrupted by the isobaric superposition due to the presence of the parent 87 Rb in the sample.

3 isotope ratios have always been difficult to analyze at low concentrations (less than 0 ppm), because there are large differences in the abundances of the isotopes 84, 86, 87 and 88. In many materials the low abundances of rubidium and their relatively low ages result in small isotope variations. Whenever analyzing solid materials, multicollector inductively coupled plasma mass spectrometry (MC-ICPMS) coupled with a laser ablation system should be able to perform a isotope analysis within minutes, while maintaining the spatial resolution and avoiding the extensive wet chemistry and warm up times characteristic of the TIMS instrument []. In this work, two alternatives are proposed for the determination of the 87 / 86 ratio in water samples. The first one, in course of implementation, will be based on an ion-molecule reaction in a dynamic reaction cell (DRC) coupled to an ICP-MS instrument, as proposed by Moens et al [6]. In the DRC + ions are reacted with CH F and converted to F + ions that can be measured free from the isobaric interference by the Rb + ions, which do not react with that gas. No chemical separation is needed; consequently the easiness and the throughput are considerably increased. The second alternative is based on the measurement of the 87 / 86 ratio using an ICP-MS DRC-e in the standard mode, after separation of Rb from by cation exchange chromatography... Interferences Results from mass spectrometric measurements of strontium isotopes have to be corrected from effects resulting from isobaric and molecular interferences. The presence of krypton (containing 86 Kr) in an argon ICP source may lead to erroneous measurements. This can be avoided using pure argon gas. Interferences in the strontium mass region in samples of natural water and carbonate matrices are due to the superposition of the 48 Ca 40 Ar + signal on 88. Due to the isobaric overlap of the 87 + and 87 Rb + ion signals, strontium and rubidium must be somehow separated from one another prior to the isotope ratio measurements. Other than the use of the DRC, rubidium interference has been eliminated either through mathematical corrections [] or sample pre-treatment. Although mathematical corrections are an easy way out, they become a significant source of uncertainty and may even fail to work properly when the []/[Rb] ratio is below 000 [7]. Alternatively, the use of a chromatographic separation is particularly suitable for the elimination of not only rubidium but also other elements present at very high levels such as calcium (as high as 500 mg/l). Selective extraction of strontium can be accomplished mainly with commercial resins using crown compounds ((4, 4, (5 ) di-t-butyl-ciclohexane-8-crown-6) or sulfonic acid as functional groups... Mass discrimination correction

4 It is necessary to use this correction when sample pre-treatment via cation-exchange is done, because traces of Rb remain in the solution. The isotopic mass discrimination of the mass spectrometer will be corrected by using an 86 / 88 internal standard assumed to be constant in nature. The use of internal normalization for mass discrimination correction is a common practice in TIMS and MC-ICP-MS. It consists in employing the exponential law: F= log(r true /R obs )/log(m 86 /m 88 ) () where R obs is the measured ratio, m 86 and m 88 are the exact masses of 86 and 88, respectively, F is the correction factor per atomic mass unit and R true is the recommended value. As a convention used by the International Union of Geosciences the value R true = 0.94 is used (USGS) [].. RESULTS AND DISCUSSION A Perkin Elmer strontium carbonate stock standard solution containing 999 µg/l and unspecified 87 / 86 isotope ratio, has been used for the tests. Solutions in the range 5-00 µg/l were prepared by appropriate dilution of the stock standard solution in HNO % and ultra-pure water. Tlabe indicates the level of purity of the stock solution. Table. Trace metal impurities in the stock solution via ICP/ICP-MS analysis The instrument used for the isotope ratios measurements of these solutions is a Perkin Elmer ELAN DRC-e ICP-mass spectrometer, in standard mode. The operational conditions are summarized in Table.

5 Table. Operational conditions of the Perkin Elmer ELAN DRC-e ICP-mass spectrometer ICP Rf Power 40 Nebulizer Gas Flow.0 L/min Plasma Gas Flow 5.00 L/min Sampling cone Nickel Skimmer Nickel Lens Voltage 6.00 Analog Stage Voltage Pulse Stage Voltage 750 RPq 0.5 The diluted standards were analyzed in three replicates. The measured 87 / 86 isotope ratio and their standard deviations for 0 µg/l and 00 µg/l solutions are shown Table. The reference value of the 87 / 86 ratio in the NIST 987 standard is Table. Results of the 87 / 86 ratio measurements 0 µg/l solution Replicate Isotope Ratio (Norm) µg/l solution Replicate Isotope Ratio (Norm) Summary Analyte Mass Ratio Mean % RSD 0.70 Summary Analyte Mass Ratio Mean % RSD Thus the average deviations between the results of the measured isotope ratios and that of

6 strontium carbonate standard are 0.05 and 0.0 (corresponding to. % and.8 % relative deviations) for the 0 µg/l and 00 µg/l solutions, respectively. 4. CONCLUSIONS The results thus far obtained are preliminary ones, but they can be considered rather promising. As was expected the experimental method using the ICP-MS ELAN DRC-e (in the standard mode) resulted quite efficient for isotope ratios determinations with concentrations of the order of some tens of ppb. The 87 / 86 isotope ratio values measured in solutions prepared from the same stock are not divergent between themselves, nor do the appreciably diverge from the NIST 987 standard. The observed relative standard deviations of the isotope rations are higher than those obtained with TIMS or MC-ICPMS, as predictable. It must be stressed that the here considered application of the 87 / 86 isotope ratio as a tracer aims at tracing waters in oil reservoir and aquifers. These applications do not exact the same rigorous accuracy of the measurement of isotope ratios as other applications do, as for instance in determining of the age of rocks. ACKNOWLEDGEMENT Work supported by the Minas Gerais State FAPEMIG (Fundação de Amparo a Pesquisa do Estado de Minas Gerais). REFERENCES. P. Z. Vroon, B.Wagt, J. M. Koornneef, G. R. Davies, Problems in obtaining precise and accurate isotope analysis from geological materials using laser ablation MC-ICPMS, Anal. Bioanal. Chem., 90, pp (008)).. S. Ehrlich, I. Gavrieli, L Dor, L. Halicz, Direct high-precision measurements of the 87 / 86 isotope ratio in natural water, carbonates and related materials by multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS), J. Anal. At. Spectrom., 6, pp 89-9 (00).. Technical Report Series nº 4, Radiotracer Applications in Industry: A Guidebook, pp (IAEA 004). 4. P. C. Smalley, A. Räheim, J. A. D. Dickson, D. Emery, 87 / 86 in waters from the Lincolnshire Limestone aquifer, England, and the potential of natural strontium isotopes as a tracer for a secondary seawater injection process in oilfields, Applied Geochemistry,, pp (988). 5. F. Vanhaecke, G. Wannemacker, L. Moens, J. Hergoten, The determination of strontium isotope ratios by means of quadrupole-base ICP-mass spectrometry: a geochronological case study, J. Anal. At. Spectrom., 4, pp (999).

7 6. L. J. Moens, F. F. Vanhaecke, D.R. Bandura, V. J. Baranov, S. D. Tanner, Elimination of isobaric interferences in ICP-Ms, using ion-molecule reaction chemistry: Rb/ age determination of magmatic rocks, a case study, J. Anal. At. Spectrom., 6, pp (00). 7. C. Brach-Papa, M. Bocxstaele, E. Ponzevera, C. R. Quétel, Fit for purpose validated method for the determination of the strontium isotope signature in mineral water samples by multi-collector inductively coupled mass spectrometry, Spectrochimica Acta Part B, 64, pp 9-4 (009).

Determination of Phosphorus and Sulfur with Dynamic Reaction Cell ICP-MS

Determination of Phosphorus and Sulfur with Dynamic Reaction Cell ICP-MS FIELD APPLICATION REPORT ICP MASS SPECTROMETRY Determination of Phosphorus and Sulfur with Dynamic Reaction Cell ICP-MS Authors: Kenneth R. Neubauer, Ph.D. Perkin Elmer Life and Analytical Sciences 710

More information

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode Lead isotope analysis: Removal of Hg isobaric interference from using ICP-QQQ in MS/MS mode Application note Authors Geochemistry and isotope analysis Glenn Woods Agilent Technologies, LDA UK Ltd., Stockport,

More information

Av. Professor Lineu Prestes 2242, São Paulo, SP Tel: +55 (11) Fax: + 55 (11)

Av. Professor Lineu Prestes 2242, São Paulo, SP Tel: +55 (11) Fax: + 55 (11) 2013 International Nuclear Atlantic Conference - INAC 2013 Recife, PE, Brazil, November 24-29, 2013 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-05-2 The use of Laser Ablation Sector

More information

Autenticity control, provenance testing and fraud detection using mass spectrometry

Autenticity control, provenance testing and fraud detection using mass spectrometry Autenticity control, provenance testing and fraud detection using mass spectrometry Abdal-Azim Al-Terkawi Ersan Özelci Melissa-Jane Monks Narendra Lagumaddepalli Venkatareddy Seyed Mohsen Jebreiil Khadem,

More information

Improvement of bulk analysis of environmental samples by using a multiple collector ICP-MS

Improvement of bulk analysis of environmental samples by using a multiple collector ICP-MS Improvement of bulk analysis of environmental samples by using a multiple collector ICP-MS IAEA Safeguards Symposium - Vienna Amélie Hubert, Anne-Claire Pottin and Fabien Pointurier 20-24 OCTOBER 2014

More information

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode The ultratrace determination of iodine in aqueous samples using the 7700x ICP-MS with oxygen reaction mode Application note Nuclear Authors Kazumi Nakano, Yasuyuki Shikamori, Naoki Sugiyama and Shinichiro

More information

Accurate Analysis of Trace Mercury in Cosmetics using the Agilent 8900 ICP-QQQ

Accurate Analysis of Trace Mercury in Cosmetics using the Agilent 8900 ICP-QQQ Application Note Consumer products Accurate Analysis of Trace Mercury in Cosmetics using the Agilent 8900 ICP-QQQ Effective removal of tungsten-based interferences on five Hg isotopes using MS/MS Authors

More information

Trace Analyses in Metal Matrices Using the ELAN DRC II

Trace Analyses in Metal Matrices Using the ELAN DRC II www.perkinelmer.com Trace Analyses in Metal Matrices Using the ELAN DRC II Introduction Analyses of matrices containing high levels of metals present a challenge for ICP-MS. First, the concentrations of

More information

Low level Os isotopic measurements using multiple ion counting

Low level Os isotopic measurements using multiple ion counting APPLICATION NOTE 30355 Low level Os isotopic measurements using multiple ion counting Authors Introduction Jean Louis Birck, Delphine Limmois, Institut de Physique du Globe de Paris, Sorbonne Paris Cité,

More information

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry Fundamentals and Applications to the Petrochemical Industry Outline Some background and fundamentals of ICPMS

More information

EFFICIENCY SIMULATION OF A HPGE DETECTOR FOR THE ENVIRONMENTAL RADIOACTIVITY LABORATORY/CDTN USING A MCNP-GAMMAVISION METHOD

EFFICIENCY SIMULATION OF A HPGE DETECTOR FOR THE ENVIRONMENTAL RADIOACTIVITY LABORATORY/CDTN USING A MCNP-GAMMAVISION METHOD 2011 International Nuclear Atlantic Conference - INAC 2011 Belo Horizonte,MG, Brazil, October 24-28, 2011 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-04-5 EFFICIENCY SIMULATION OF

More information

Use of ICP-MS in analysing radioisotopes. Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark

Use of ICP-MS in analysing radioisotopes. Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark Use of ICP-MS in analysing radioisotopes Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark Inductively Coupled Plasma Mass Spectrometry (ICP-MS) History ICP-AES

More information

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY Edited by AKBAR MONTASER George Washington University Washington, D.C. 20052, USA WILEY-VCH New York Chichester Weinheim Brisbane Singapore Toronto CONTENTS

More information

Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry

Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry Zhichao Lin, Kathryn Emanuele, Stephanie Healey, and Patrick Regan Analytical Branch Winchester Engineering and

More information

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode Application note Semiconductor Authors Michiko Yamanaka, Kazuo Yamanaka and Naoki

More information

Hands on mass spectrometry: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment

Hands on mass spectrometry: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment : ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment Max Planck Institute for Nuclear Physics, Heidelberg, Germany E-mail: mykola.stepaniuk@mpi-hd.mpg.de Stefano Nisi E-mail: stefano.nisi@lngs.infn.it

More information

Accelerator Mass Spectroscopy

Accelerator Mass Spectroscopy Accelerator Mass Spectroscopy Accelerator Mass Spectroscopy (AMS) is a highly sensitive technique that is useful in isotopic analysis of specific elements in small samples (1mg or less of sample containing

More information

COMBINED PROCEDURE USING RADIOCHEMICAL SEPARATION OF PLUTONIUM, AMERICIUM AND URANIUM RADIONUCLIDES FOR ALPHA-SPECTROMETRY

COMBINED PROCEDURE USING RADIOCHEMICAL SEPARATION OF PLUTONIUM, AMERICIUM AND URANIUM RADIONUCLIDES FOR ALPHA-SPECTROMETRY 2009 International Nuclear Atlantic Conference - INAC 2009 Rio de Janeiro,RJ, Brazil, September27 to October 2, 2009 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-03-8 COMBINED PROCEDURE

More information

Journal of Analytical Atomic Spectrometry

Journal of Analytical Atomic Spectrometry / Journal Homepage / Table of Contents for this issue PAPER www.rsc.org/jaas Journal of Analytical Atomic Spectrometry Systematic evaluation of a strontium-specific extraction chromatographic resin for

More information

Detection of iron species using inductively coupled plasma mass spectrometry under cold plasma temperature conditions

Detection of iron species using inductively coupled plasma mass spectrometry under cold plasma temperature conditions Spectrochimica Acta Part B 2001 123128 Analytical note Detection of iron species using inductively coupled plasma mass spectrometry under cold plasma temperature conditions Li-Shing Huang a,b, King-Chuen

More information

Trace Elements - Definitions

Trace Elements - Definitions Trace Elements - Definitions Elements that are not stoichiometric constituents in phases in the system of interest For example, IG/MET systems would have different trace elements than aqueous systems Do

More information

PRESSURE DROP OF FLOW THROUGH PERFORATED PLATES

PRESSURE DROP OF FLOW THROUGH PERFORATED PLATES 27 International Nuclear Atlantic Conference - INAC 27 Santos, SP, Brazil, September 3 to October 5, 27 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-2-1 PRESSURE DROP OF FLOW THROUGH

More information

JRP SIB09 Elements GOOD PRACTICE GUIDE ON DEALING WITH INTERFERENCES IN ICP-MS FOR INVESTIGATING HIGH PURITY MATERIALS. Deliverable 1.2.

JRP SIB09 Elements GOOD PRACTICE GUIDE ON DEALING WITH INTERFERENCES IN ICP-MS FOR INVESTIGATING HIGH PURITY MATERIALS. Deliverable 1.2. JRP SIB09 Elements GOOD PRACTICE GUIDE ON DEALING WITH INTERFERENCES IN ICP-MS FOR INVESTIGATING HIGH PURITY MATERIALS Deliverable 1.2.32 (June 2015) Author : Guillaume Labarraque 1 Introduction High purity

More information

IMPROVING DATA QUALITY WITH ADVANCED INSTRUMENTATION UTILIZING MULTIPLE INTERFERENCE REDUCTION TECHNOLOGIES

IMPROVING DATA QUALITY WITH ADVANCED INSTRUMENTATION UTILIZING MULTIPLE INTERFERENCE REDUCTION TECHNOLOGIES DoD Environmental Data Quality Workshop, St. Louis, MO IMPROVING DATA QUALITY WITH ADVANCED INSTRUMENTATION UTILIZING MULTIPLE INTERFERENCE REDUCTION TECHNOLOGIES Jamie Fox Brooks Applied Labs www.brooksapplied.com

More information

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company Why ICP Mass Spectrometry? Ultra-trace multi-element analytical

More information

Determination of Ni isotopes in nickel material from the Rossi reactor

Determination of Ni isotopes in nickel material from the Rossi reactor Datum 1(6) 2012 04 12 Determination of Ni isotopes in nickel material from the Rossi reactor 1) Task Per Andersson & Hans Schöberg Laboratory for Isotope Geology, Swedish Museum of Natural History Box

More information

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS Accurate analysis of neptunium in a uranium matrix, using ICP-QQQ with MS/MS Application note Nuclear, environmental Authors Garry Duckworth, Springfields Fuels Ltd, K, Glenn Woods, Agilent Technologies,

More information

Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Debjani Banerjee Department of Chemical Engineering IIT Kanpur

Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Debjani Banerjee Department of Chemical Engineering IIT Kanpur Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Debjani Banerjee Department of Chemical Engineering IIT Kanpur Introduction What is ICP-MS? Inductively Coupled Plasma Mass Spectrometry Mass spectrometry

More information

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS APPLICATION NOTE ICP - Mass Spectrometry Author Kenneth Ong PerkinElmer, Inc. Singapore Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS Introduction The control of impurity

More information

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS APPLICATION NOTE 434 Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS Authors Introduction Marcus Manecki, Daniel Kutscher, Shona McSheehy

More information

MASS SPECTROMETRIC TECHNIQUES FOR THE RAPID CHARACTERIZATION AND FINGERPRINTING OF NUCLEAR FUEL MATERIALS

MASS SPECTROMETRIC TECHNIQUES FOR THE RAPID CHARACTERIZATION AND FINGERPRINTING OF NUCLEAR FUEL MATERIALS http://wateriso.utah.edu/waterisotopes/media/isomaps/jpegs/o_global/oma_global.jpg S13: State of the Art Environmental Sample Analysis NOVEL MASS SPECTROMETRIC TECHNIQUES FOR THE RAPID CHARACTERIZATION

More information

DISCLAIMER: This method:

DISCLAIMER: This method: Inorganic arsenic determination in fresh mussels using water bath extraction and anion exchange chromatography-inductively coupled plasma mass spectrometry DISCLAIMER: This method: - has to be considered

More information

Automating Sample Purification MC-ICPMS. Elemental Scientific ICP ICPMS AA

Automating Sample Purification MC-ICPMS. Elemental Scientific ICP ICPMS AA prepfast-mc Automating Sample Purification MC-ICPMS Elemental Scientific ICP ICPMS AA 1 prepfast-mc Brief and system schematics...2 Uranium Isotopes...3 Strontium Isotopes...6 Boron Isotopes...9 Brief

More information

Isotope Dilution Mass Spectrometry

Isotope Dilution Mass Spectrometry Isotope Dilution Mass Spectrometry J. Ignacio Garcia Alonso and Pablo Rodriguez-Gonzalez Faculty of Chemistry, University of Oviedo, Oviedo, Spain E-mail: jiga@uniovi.es, rodriguezpablo@uniovi.es RSC Publishing

More information

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS Application note Environmental Authors Steve Wilbur, Craig Jones Agilent Technologies,

More information

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction. Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS Application Environmental Author Steven Wilbur Agilent Technologies, Inc. 3380 146th Place, SE, Suite 300 Bellevue, WA

More information

ENVG FALL ICP-MS (Inductively Coupled Plasma Mass Spectrometry) Analytical Techniques

ENVG FALL ICP-MS (Inductively Coupled Plasma Mass Spectrometry) Analytical Techniques ENVG 60500 FALL 2013 ICP-MS (Inductively Coupled Plasma Mass Spectrometry) Analytical Techniques HISTORY In the 1940s, arc and high-voltage spark spectrometry became widely utilized for metal analysis

More information

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry APPLICATION NOTE Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry AN43227 Antonella Guzzonato 1, Shona McSheehy Ducos

More information

Unmatched Removal of Spectral Interferences in ICP-MS Using the Agilent Octopole Reaction System with Helium Collision Mode Application

Unmatched Removal of Spectral Interferences in ICP-MS Using the Agilent Octopole Reaction System with Helium Collision Mode Application Unmatched Removal of Spectral Interferences in ICP-MS Using the Agilent Octopole Reaction System with Helium Collision Mode Application Metals Analysis Authors Ed McCurdy, Glenn Woods and Don Potter Agilent

More information

ICPMS Doherty Lecture 1

ICPMS Doherty Lecture 1 ICPMS Doherty Lecture 1 Mass Spectrometry This material provides some background on how to measure isotope abundances by means of mass spectrometry. Mass spectrometers create and separate ionized atoms

More information

GUAMA RIVER AND GUAJARA BAY, BELEM - AMAZON REGION

GUAMA RIVER AND GUAJARA BAY, BELEM - AMAZON REGION 2007 International Nuclear Atlantic Conference - INAC 2007 Santos, SP, Brazil, September 30 to October 5, 2007 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-02-1 210 Pb GEOCHRONOLOGY

More information

Low Level Detection of Priority Inorganic Pollutants in Groundwater By Darren Crichton and Anthony Neumann

Low Level Detection of Priority Inorganic Pollutants in Groundwater By Darren Crichton and Anthony Neumann Low Level Detection of Priority Inorganic Pollutants in Groundwater By Darren Crichton and Anthony Neumann Abstract Introduction: Arsenic, selenium, vanadium and chromium are identified in the Priority

More information

Low Level Detection of Priority Inorganic Pollutants in Water. Anthony Neumann, MSc Darren Crichton, BSc

Low Level Detection of Priority Inorganic Pollutants in Water. Anthony Neumann, MSc Darren Crichton, BSc Low Level Detection of Priority Inorganic Pollutants in Water Anthony Neumann, MSc Darren Crichton, BSc Priority List of Pollutants Consists of 16 metals and/or transitional elements. Enter the human food

More information

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS Authors Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS Application Note Food safety Craig Jones and Jenny Nelson Agilent Technologies, USA Introduction In the U.S., marijuana remains

More information

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode Application note Semiconductor Author Katsuo Mizobuchi Masakazu

More information

Antonio Simonetti University of Notre Dame

Antonio Simonetti University of Notre Dame Antonio Simonetti University of Notre Dame Precision and accuracy on individual isotopic measurements suffer due to matrix effects and isobaric interferences? Availability of suitable reference materials,

More information

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ Application Note Semiconductor Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ Authors Kazuo Yamanaka and Kazuhiro Sakai Agilent Technologies, Tokyo, Japan Introduction

More information

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode Application Note Pharmaceutical Authors Rebeca Santamaria-Fernandez, SheilaMerson,

More information

dating of geological samples by laser ablation ICPMS

dating of geological samples by laser ablation ICPMS U-Th-Pb dating of geological samples by laser ablation ICPMS Winter Conference on Plasma Spectrochemistry Fort Lauderdale, Florida, January 3, 2004 Short course ST-19 Jan Košler 1 and Mike Tubrett 2 1.

More information

Very recently Roussis and Proulx clearly demonstrated

Very recently Roussis and Proulx clearly demonstrated APPLICATION NOTE Deconvolution of Isobaric Interferences in Mass Spectra Juris Meija and Joseph A. Caruso Department of Chemistry, University of Cincinnati, Cincinnati, Ohio, USA The concept of isobar

More information

Determination of Trace Metals in Human Urine Using the NexION 300 ICP-MS

Determination of Trace Metals in Human Urine Using the NexION 300 ICP-MS application Note ICP Mass Spectrometry Authors: David Bass Daniel Jones PerkinElmer, Inc. Shelton, CT USA Determination of Trace Metals in Human Urine Using the NexION 300 ICP-MS Abstract This application

More information

Jong-Sik Ryu, Min Seok Choi, Youn-Joong Jeong and Chang-sik Cheong *

Jong-Sik Ryu, Min Seok Choi, Youn-Joong Jeong and Chang-sik Cheong * Ryu et al. Journal of Analytical Science and Technology 2013, 4:8 TECHNICAL NOTE Open Access -Nd isotopic analysis of mixed standard solutions by multi-collector inductively coupled plasma mass spectrometry:

More information

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company Key Analytical Issues: Sample Preparation, Interferences and Variability Tim Shelbourn, Eli Lilly and Company Presentation Outline Sample preparation objectives and challenges Some common interferences

More information

The problems as we saw them were;

The problems as we saw them were; My name is Michael Murphy and I work in the isotope laboratory in the Department of Geology, University College Dublin. I am going to talk to you about rubidium, strontium, samarium and neodymium elemental

More information

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe: February 20, 2012 Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Subject: ICP-MS Report Job Number: S0CHG688 Dear Joe: Please find enclosed the procedure report for the analysis

More information

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma THE PLASMA Inductively Coupled Plasma Mass Spectrometry (ICP-MS) What is a Plasma? - The magnetic field created by a RF (radio frequency) coil produces a current within a stream of Argon (Ar) gas, which

More information

Nu Plasma II - Collector Configuration

Nu Plasma II - Collector Configuration Nu Plasma II - Collector Configuration Nu Plasma II - Collector Configuration U-Th-Pb mass array 238U 232Th 207Pb 206Pb 208Pb 202Hg 204Pb, 204Hg Peak Alignment/Coincidence 238 U 232 Th 208 Pb 207 Pb 206

More information

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques Chapter 9 Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques Emission Spectroscopy Flame and Plasma Emission Spectroscopy are based upon those particles that are

More information

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS Application note Energy and fuels Authors Jenny Nelson, Agilent Technologies, USA Ed McCurdy, Agilent Technologies, UK Introduction

More information

Rapid Determination of Ra-226 in Environmental Samples

Rapid Determination of Ra-226 in Environmental Samples Rapid Determination of Ra-226 in Environmental Samples S. L. Maxwell, B.K. Culligan, and P. J. Shaw Savannah River National Laboratory Aiken, SC November 3, 2011 57th Radiobioassay and Radiochemical Measurements

More information

Advantages of ICP-QQQ for nuclear waste characterisation

Advantages of ICP-QQQ for nuclear waste characterisation NKS-B ICPM Users seminar, 2017 Advantages of ICP-QQQ for nuclear waste characterisation Phil Warwick University of Southampton GAU-Radioanalytical Laboratories A major provider of radioanalytical expertise

More information

Analytical Approaches to Arsenic

Analytical Approaches to Arsenic Analytical Approaches to Arsenic (and Selenium) Analysis in Foods Brian Jackson Trace Element Analysis Core Dartmouth College Arsenic in food Arsenic levels in rice and rice products FDA data WHO data

More information

Rapid Analytical Methods for Determination of Actinides

Rapid Analytical Methods for Determination of Actinides Rapid Analytical Methods for Determination of Actinides Xiongxin Dai Chalk River Laboratories Dosimetry Services Branch Atomic Energy of Canada Limited November 17, 2009 NKS-B RadWorkshop Risø-DTU, Roskidle,

More information

Uncertainty in Measurement of Isotope Ratios by Multi-Collector Mass Spectrometry

Uncertainty in Measurement of Isotope Ratios by Multi-Collector Mass Spectrometry 1 IAEA-CN-184/168 Uncertainty in Measurement of Isotope Ratios by Multi-Collector Mass Spectrometry R. Williams Lawrence Livermore National Laboratory Livermore, California U.S.A. williams141@llnl.gov

More information

Environmental Sample Analysis Advances and Future Trends

Environmental Sample Analysis Advances and Future Trends Environmental Sample Analysis Advances and Future Trends D.Donohue Office of Safeguards Analytical Services Environmental Sample Laboratory International Atomic Energy Agency Contents Introduction Bulk

More information

The use of LA-SF-ICP-MS for nuclear forensics purposes: uranium isotope ratio analysis

The use of LA-SF-ICP-MS for nuclear forensics purposes: uranium isotope ratio analysis J Radioanal Nucl Chem (2013) 295:99 104 DOI 10.1007/s10967-012-1980-y The use of LA-SF-ICP-MS for nuclear forensics purposes: uranium isotope ratio analysis Rafael C. Marin Jorge E. S. Sarkis Marcos R.

More information

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW Inductively Coupled Plasma Mass Spectrometry (ICP-MS) What is a Plasma? - The magnetic field created by a RF (radio frequency) coil produces

More information

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) The Agilent

More information

Precise Pb isotope analysis of igneous rocks using fully-automated double spike thermal ionization mass spectrometry (FA -DS- TIMS)

Precise Pb isotope analysis of igneous rocks using fully-automated double spike thermal ionization mass spectrometry (FA -DS- TIMS) JAMSTEC-R IFREE Special Issue, November 2009 Precise Pb isotope analysis of igneous rocks using fully-automated double spike thermal ionization mass spectrometry (FA -DS- TIMS) Takashi Miyazaki 1*, Nobuyuki

More information

DEVELOPMENT OF A METHODOLOGY FOR LOW-ENERGY X-RAY ABSORPTION CORRECTION IN BIOLOGICAL SAMPLES USING RADIATION SCATTERING TECHNIQUES

DEVELOPMENT OF A METHODOLOGY FOR LOW-ENERGY X-RAY ABSORPTION CORRECTION IN BIOLOGICAL SAMPLES USING RADIATION SCATTERING TECHNIQUES 2009 International Nuclear Atlantic Conference - INAC 2009 Rio de Janeiro,RJ, Brazil, September27 to October 2, 2009 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-03-8 DEVELOPMENT

More information

Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution

Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution APEX-ACM Ca Ratios Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution Abstract High resolution ICP-MS is used

More information

Error Analysis. The big questions are: - What value best represents a set of measurements and how reliable is it?

Error Analysis. The big questions are: - What value best represents a set of measurements and how reliable is it? The big questions are: - What value best represents a set of measurements and how reliable is it? An ICP analysis yields LOTS of data typically, 9 individual measurements for each analyte for each sample

More information

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast Application Note Environmental Authors Austin Schultz and Jake Unnerstall, Elemental Scientific, Omaha NE, USA Steve Wilbur,

More information

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS Application note Semiconductor Author Naoki Sugiyama Agilent Technologies, Tokyo,

More information

Quantitative analysis of high purity metals using laser ablation coupled to an Agilent 7900 ICP-MS

Quantitative analysis of high purity metals using laser ablation coupled to an Agilent 7900 ICP-MS Quantitative analysis of high purity metals using laser ablation coupled to an Agilent 7900 ICP-MS Application note Metals Analysis & Production Authors Naoki Sugiyama and Mineko Omori Agilent Technologies,

More information

high temp ( K) Chapter 20: Atomic Spectroscopy

high temp ( K) Chapter 20: Atomic Spectroscopy high temp (2000-6000K) Chapter 20: Atomic Spectroscopy 20-1. An Overview Most compounds Atoms in gas phase high temp (2000-6000K) (AES) (AAS) (AFS) sample Mass-to-charge (ICP-MS) Atomic Absorption experiment

More information

ELEMENTAL ANALYSIS OF GLASS EXAMINATIONS (PART 1) Module 4

ELEMENTAL ANALYSIS OF GLASS EXAMINATIONS (PART 1) Module 4 ELEMENTAL ANALYSIS OF GLASS EXAMINATIONS (PART 1) Module 4 Tatiana Trejos, M.Sc Florida International University Department of Chemistry and Biochemistry International Forensic Research Institute Outline

More information

Effect of Sampling Depth on the Analyte Response in Laser Ablation Inductively Coupled Plasma Mass Spectrometry

Effect of Sampling Depth on the Analyte Response in Laser Ablation Inductively Coupled Plasma Mass Spectrometry JLMN-Journal of Laser Micro/Nanoengineering Vol., No., Effect of Sampling Depth on the Analyte Response in Laser Ablation Inductively Coupled Plasma Mass Spectrometry Zhongke WANG *, Bodo Hattendorf and

More information

MM800 (a) Ion Exchange and ICP/MS of Uranium in Water. 1.0 Scope and Application

MM800 (a) Ion Exchange and ICP/MS of Uranium in Water. 1.0 Scope and Application Analytical/Inorganic MM800 (a) Ion Exchange and ICP/MS of Uranium in Water 1.0 Scope and Application This procedure can be used to determine U concentration or isotopic-ratio composition in groundwater

More information

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application Semiconductor Author Junichi Takahashi Koichi Yono Agilent Technologies, Inc. 9-1, Takakura-Cho, Hachioji-Shi,

More information

EXPERIMENTAL DETERMINATION OF NEUTRONIC PARAMETERS IN THE IPR-R1 TRIGA REACTOR CORE

EXPERIMENTAL DETERMINATION OF NEUTRONIC PARAMETERS IN THE IPR-R1 TRIGA REACTOR CORE 2011 International Nuclear Atlantic Conference - INAC 2011 Belo Horizonte,MG, Brazil, October 24-28, 2011 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-04-5 EXPERIMENTAL DETERMINATION

More information

Major element compositions of the minerals were obtained on polished thin sections using a

Major element compositions of the minerals were obtained on polished thin sections using a DR846 APPENDIX A: ANALYTICAL METHODS Mineral chemistry Major element compositions of the minerals were obtained on polished thin sections using a Cameca SX electron microprobe fitted with five spectrometers

More information

UNIVERSITY OF CALGARY. Measurement of the absolute isotopic composition and atomic weight

UNIVERSITY OF CALGARY. Measurement of the absolute isotopic composition and atomic weight UNIVERSITY OF CALGARY Measurement of the absolute isotopic composition and atomic weight of molybdenum by multiple collector inductively coupled plasma mass spectrometry by Adam John Mayer A THESIS SUBMITTED

More information

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer is powerful simultaneous full

More information

Atomic Spectroscopy AA/ICP/ICPMS:

Atomic Spectroscopy AA/ICP/ICPMS: Atomic Spectroscopy AA/ICP/ICPMS: A Comparison of Techniques VA AWWA/VWEA Lab Practices Conference July 25, 2016 Dan Davis Shimadzu Scientific Instruments AA/ICP/ICPMS: A Comparison of Techniques Topics

More information

Main Challenges and Uncertainties for Oil Production from Turbidite Reservoirs in Deep Water Campos Basin, Brazil*

Main Challenges and Uncertainties for Oil Production from Turbidite Reservoirs in Deep Water Campos Basin, Brazil* Main Challenges and Uncertainties for Oil Production from Turbidite Reservoirs in Deep Water Campos Basin, Brazil* Carlos H. Bruhn 1, Antonio Pinto 1, and Paulo R. Johann 1 Search and Discovery Article

More information

The Easy Guide to: Inductively Coupled Plasma- Mass Spectrometry (ICP-MS)

The Easy Guide to: Inductively Coupled Plasma- Mass Spectrometry (ICP-MS) The Easy Guide to: Inductively Coupled Plasma- Mass Spectrometry (ICP-MS) By Arianne Bazilio & Jacob Weinrich December 2012 Contents Introduction... 2 Sample Introduction... 3 Torch... 4 Interface... 6

More information

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS TECHNICAL NOTE 4322 Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS Keywords Argon gas dilution, AGD, High matrix samples, Seawater Goal To critically

More information

INVESTIGATION OF ICP-OES ANALYSIS FOR DETERMINATION OF TRACE LEAD IN LEAD-FREE ALLOY

INVESTIGATION OF ICP-OES ANALYSIS FOR DETERMINATION OF TRACE LEAD IN LEAD-FREE ALLOY C1_C0011 1 INVESTIGATION OF ICP-OES ANALYSIS FOR DETERMINATION OF TRACE LEAD IN LEAD-FREE ALLOY Janya Buanuam,* Thareerut Woratanmanon, Temporn Sookawee Regional Failure Analysis and Reliability Laboratory,

More information

Sample Analysis Design PART II

Sample Analysis Design PART II Sample Analysis Design PART II Sample Analysis Design Generating high quality, validated results is the primary goal of elemental abundance determinations It is absolutely critical to plan an ICP-MS analysis

More information

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009] 2 Vol. 36(1) [Jan. Feb. 2009] BRIEFING h233i Elemental Impurities Procedures. This proposed new general test chapter is the second of two being developed to replace the general test chapter Heavy Metals

More information

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis Agilent ICP-MS Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis High Sample Matrix Tolerance Superior & Simple Interference Removal Ultra Wide Linear

More information

Determination of Copper in Uniformly-Doped Silicon Thin Films by Isotope-Dilution Inductively Coupled Plasma Mass Spectrometry

Determination of Copper in Uniformly-Doped Silicon Thin Films by Isotope-Dilution Inductively Coupled Plasma Mass Spectrometry Determination of Copper in Uniformly-Doped Silicon Thin Films Bull. Korean Chem. Soc. 2001, Vol. 22, No. 2 205 Determination of Copper in Uniformly-Doped Silicon Thin Films by Isotope-Dilution Inductively

More information

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS. ICP-MS plasma 17OO High Resolution Multi-Collector ICP-MS www.nu-ins.com Plasma 1700 & Sapphire 1700 Plasma 1700: Large Geometry Multi-Collector Inductively Coupled Plasma Mass Spectrometer For more information

More information

MATHEMATICAL MODEL OF RADON ACTIVITY MEASUREMENTS

MATHEMATICAL MODEL OF RADON ACTIVITY MEASUREMENTS 2015 International Nuclear Atlantic Conference - INAC 2015 São Paulo, SP, Brazil, October 4-9, 2015 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-06-9 MATHEMATICAL MODEL OF RADON ACTIVITY

More information

Suppression of in-cell generated interferences in a reaction cell ICP-MS by bandpass tuning and kinetic energy discrimination

Suppression of in-cell generated interferences in a reaction cell ICP-MS by bandpass tuning and kinetic energy discrimination Suppression of in-cell generated interferences in a reaction cell ICP-MS by bandpass tuning and kinetic energy discrimination Bodo Hattendorf* and Detlef Günther ETH Zürich, ETH Hönggerberg, CH-8093 Zürich,

More information

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES Application Note - AN1508 Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES Introduction Page 1 The combination of hydride generation with

More information

Fergus Keenan Shona McSheehy Julian Wills

Fergus Keenan Shona McSheehy Julian Wills Novel QCell Technology for Inference Removal in ICP-MS - Combining Low Mass Filtration with Kinetic Energy Discrimination Fergus Keenan Shona McSheehy Julian Wills 1 The world leader in serving science

More information

Automated Determination of PPQ Levels of Thorium in High Purity Copper

Automated Determination of PPQ Levels of Thorium in High Purity Copper PPQ Levels of Th in High Purity Cu TRUFAST ICPMS Automated Determination of PPQ Levels of Thorium in High Purity Copper Using the ESI TRUFAST System and ICPMS Detection By Nathan Saetveit, PhD and Dan

More information

Additional Analytical Methods. Detrital zircon samples were collected from nine fine-, medium-, and coarse-grained

Additional Analytical Methods. Detrital zircon samples were collected from nine fine-, medium-, and coarse-grained GSA Data Repository 2016214 Leary, R.J., DeCelles, P.G., Quade, J., Gehrels, G.E., and Waanders, G., 2016, The Liuqu Conglomerate, southern Tibet: Early Miocene basin development related to deformation

More information