1 Zebron MultiResidue GC Columns A new Generation of Columns for Pesticide Analysis
2 MultiResidue Optimized for pesticide, herbicide and insecticide analysis The use of many pesticides has been limited or discontinued due to the health and environmental risks they pose. However, the persistence of these compounds in the environment has left many sites heavily contaminated and in need of remediation. There is also international concern for the residual level of pesticides in foods, especially those imported from countries where banned pesticides are still permitted. Though the standard method for pesticide testing varies throughout the world, many labs use Electron Capture Detectors (ECD), Nitrogen Phosphorous Detectors (NPD) or Flame Photometric Detectors (FPD) because of the sensitivity level they offer for specific compound classes. While these detectors are extremely sensitive, they do not provide spectral confirmation of the analyte. In order to provide positive confirmation, Mass Spectrometry (MS) must be used. The GC/MS can be used in Selected Ion Monitoring (SIM) mode to provide sensitivity levels similar to the previously mentioned detectors, while also providing positive confirmation of the analyte in question. Regardless of the technique, the new MultiResidue GC columns have been optimized for pesticides, herbicide, or insecticide analysis. Each column has a unique selectivity that allows them to be used together in dual column confirmation analysis. Both phases are MS Certified, so they can also be used on MS to confirm results. We have run a number of pesticide compounds on these phases. If you don t find the application you are looking for in this brochure, be sure to contact your local Phenomenex representative.
3 Zebron MultiResidue (MR) Columns Optimized Selectivity Two Complementary Phase Chemistries MS Certified Bleed Levels High Temperature Limits (0/0 C) Very Low Column Activity Table of Contents Compound ass Official Method Detection Page Number Chlorinated Pesticides EPA 0A ECD,, 9, Multi-Pesticide Residue PDP MS Aroclors EPA 0 ECD Organophosphorous Pesticides EPA 0//A FID Chlorophenoxyacid Herbicides EPA / ECD Polyaromatic Hydrocarbons EPA 0/00 MSD Polychlorinated Biphenyls (PCBs) DIN ECD Phenomenex Tel: 0--0 Fax: 0-- Web:
4 MultiResidue A New Generation of Columns for Pesticide Analysis Optimized Selectivity Many pesticide compounds have very similar structures or have isomers that are present in the product. Zebron MultiResidue phases were developed to provide optimum selectivity for a variety of pesticide compounds. Every analysis is unique, but we can help you determine the best phase to use in order to resolve your pesticide sample. Figure : Selectivity of DDT, DDD, and DDE isomers at ng on column using MS Sample:. o,p-dde. p,p-dde. o,p-ddd MR-. o,p-ddt. p,p-ddd. p,p-ddt min App ID: Abundance m/z--> Low Bleed No 0 bleed ions at 0 C Acquisition Spectra Low Bleed Zebron has developed a reputation for low column bleed and high temperature limits and Zebron MultiResidue columns are no different. The columns are made using an extremely stable siloxane-based polymer that contains absolutely no cyano functionality. Our Engineered Self Crosslinking (ESC) bonding process makes both columns MS certified, allowing for unmatched spectral integrity even for low-level samples. Abundance m/z--> NIST Reference Specra
5 Low Column Activity Many pesticides are sensitive to system activity and readily breakdown. This can be a significant problem when working with low level samples and sensitive detectors such as ECD. Zebron MultiResidue columns have been completely deactivated and provide excellent peak shape for even the most active compounds. Figure : Breakdown for sensitive pesticides on Zebron MultiResidue columns Endrin Breakdown. % Degradation Products MR- App ID: Breakdown. % DDT Universal Compatibility Zebron MultiResidue GC columns are compatible with all systems and all detectors. It doesn t matter if it s an Agilent 90 with a μecd or a Thermo Finnigan Trace DSQ, Zebron columns provide reliable results every time. MR- App ID: Tunable Selectivity Zebron MultiResidue GC columns were developed specifically for pesticide analysis. Their unique selectivity improves the separation of all classes of pesticides, herbicides, and insecticides. Since the columns are MS Certified, samples can be pre-screened using analyte specific detectors, and then confirmed using MS. Sensitive and Stable Figure : Repeatability at pg on-column concentration of various pesticides using Zebron MR- and MR- columns,00,000,00,000 Response,00,000,00,000,00,000,000,000 00,000 00,000 MR- Response,00,000,00,000,000,000 00,000 00,000 MR- 00,000 Sample Number 00,000 Sample Number Table : Relative standard deviation (RSD) for five replicate injections of pesticide at pg on-column concentration Analyte MR- % RSD MR- % RSD Lindane (γ-bhc).. Heptachlor..0 Dieldrin.. Endrin.. DDT.9. Methoxychlor..9 Phenomenex Tel: 0--0 Fax: 0-- Web:
6 MultiResidue Area Count,000 0,000,000 0,000,000 0 MR- Performance That Exceeds US EPA Method 0A Specifications The EPA outlines strict performance guidelines that must be met for compound linearity, percent relative standard deviation (% RSD), and breakdown of DDT and Endrin. Column resolution and performance are critical in meeting these requirements. The data below was calculated using EPA Method 0A guidelines. Endrin R = DDT R = Parts Per Billion (ppb) Table : Five-point calibration curve at, 0,,00, and 0 ppb Analyte Zebron MR- % RSD* Zebron MR- % RSD* US EPA Specifications a-bhc..9 < 0 γ-bhc (Lindane)..0 < 0 b-bhc. 9. < 0 d-bhc.90. < 0 Heptachlor.. < 0 Aldrin.. < 0 Heptachlor epoxide.0. < 0 g-chlordane.. < 0 a-chlordane.9.9 < 0 Endosulfan I.9.9 < 0 DDE.. < 0 Dieldrin.. < 0 Endrin.. < 0 DDD.9. < 0 Endosulfan II.. < 0 Endrin aldehyde.. < 0 DDT.0. < 0 Endrin sulfate..0 < 0 Methoxychlor.9. < 0 Endrin ketone..9 < 0 Average.. < 0 *Calculated using response factors as per EPA guidelines Area Count,000 0,000,000 0,000,000 0 MR- Endrin R = DDT R = Parts Per Billion (ppb) Table : Percent breakdown of endrin & DDT as per EPA guidelines Analyte Zebron MR- % Breakdown Zebron MR- % Breakdown US EPA Requirements Endrin..0 < DDT..9 <
7 Baseline Resolution of all 0 Chlorinated Pesticides! The US EPA regulates the testing of 0 specific chlorinated pesticides under the official Method 0A. The method specifies an Electron Capture Detector (ECD), which is extremely sensitive for chlorinated compounds. However it does not provide any confirmatory information about the peak. To reduce the occurrence of misidentifications, the method requires the use of two GC columns of dissimilar selectivity in a parallel configuration. The EPA considers an analyte s presence confirmed if it has a peak at the pre-determined retention time on both columns. The unique selectivity of Zebron MultiResidue columns allows for baseline resolution (R s >.) of all compounds with two elution order changes between the columns! 9 0 MR- 0 9 App ID: min Enhanced Performance Two elution order changes between the columns MR US EPA 0A App ID: 0 min Column: Zebron MultiResidue- Zebron MultiResidue- Dimensions: 0 meter x 0. mm x 0.0 µm 0 meter x 0. mm x 0. µm Part No.: HM-G0-; HM-G0- Injection: 0 C, µl Carrier Gas: ml/min (constant flow) Oven Program: 00 C for 0. min to 0 C/min for min Detector: 0 C Notes: Columns connected using a m Z-Guard and a Y-splitter Injector m Z-Guard Zebron MR- Zebron MR- Y-Splitter ECD Detector ECD Detector Sample:.,,,-Tetrachloro-m-xylene (TCX). -Bromo--nitrobenzene. a-bhc. g-bhc (Lindane). b-bhc. δ-bhc. Heptachlor. Aldrin 9. Heptachlor epoxide 0. g-chlordane. a-chlordane., -DDE. Edosulfan I. Dieldrin. Endrin., -DDD. Endosulfan II., -DDT 9. Endrin aldehyde 0. Methoxychlor. Endosulfan sulfate. Endrin ketone. Decachlorobiphenyl (DCB) Phenomenex Tel: 0--0 Fax: 0-- Web:
8 MultiResidue Increase Your Lab s Productivity Zebron MultiResidue columns were designed to provide optimized resolution of all classes of pesticides. This unique selectivity allows your lab to maintain separation of critical compounds even when analysis times are shortened by more than 0 %. The increase in lab productivity makes sure you get results to your customers on time, even for rush samples. Instruments Required to Run 00 Samples Per Day 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples 0 Samples MR- 9 0 Standard Conditions 90 App ID: 9 0 min MR App ID: 0 0 min Column: Zebron MultiResidue- Zebron MultiResidue- Dimensions: 0 meter x 0. mm x 0.0 μm 0 meter x 0. mm x 0.0 μm Part No.: HK-G0-; HK-G0- Injection: 0 C, µl Carrier Gas: ml/min (constant flow) Oven Program: 90 C for 0. min to 0 C/min for min Detector: 0 C
9 Same Columns + Optimized Conditions = Increased Productivity. Instruments Required to Run 00 Samples Per Day Samples Samples Samples Samples with time to spare! These instruments available for other analysis MR- MR- Column: Zebron MultiResidue- Zebron MultiResidue- Dimensions: 0 meter x 0. mm x 0.0 μm 0 meter x 0. mm x 0.0 μm Part No.: HK-G0-; HK-G0- Optimized Conditions min App ID: App ID: min Sample for both columns:.,,,-tetrachloro-m-xylene (TCX). -Bromo--nitrobenzene. a-bhc. g-bhc (Lindane). b-bhc. d-bhc. Heptachlor. Aldrin 9. Heptachlor eoxide 0. g-chlordane. a-chlordane., -DDE. Endosulfan I. Dieldrin. Endrin., -DDD. Endosulfan II., -DDT 9. Endrin aldehyde 0. Methoxychlor. Endosulfan sulfate. Endrin ketone. Decachlorobiphenyl (DCB) Injection: 0 C, µl Carrier Gas: ml/min (constant flow) Oven Program: 0 C for 0. min to 0 0 C/min to 0 0 C/min for min Detector: 0 C % Shorter Analysis Almost no change in resolution! Tech Tip: High flow rates reduce a compound s residence time in the inlet. This can significantly reduce injection port breakdown for sensitive compounds such as Endrin & DDT. Phenomenex Tel: 0--0 Fax: 0-- Web:
10 MultiResidue Multi-Pesticide Residue Testing by GC/MS Pesticides are widely used by farmers to control pests, weeds and molds that would otherwise decrease crop production. While this has significantly increased worldwide food productions, these same pesticides pose significant health and environmental risks. The restrictions for specific pesticides differ from one country to the next. As world trade increases, the potential threat to other countries populations increases. This is especially true in the European Union, where produce can be transported from one country to another quite easily. For this reason, pesticides are the subject of increasing regulation. Since many different types of pesticides can be used on the same food product, multiple residue screening approaches are used to test for more than 00 compounds. Gas Chromatography (GC) is still the most common test method for the majority of pesticide classes. While ECD or NPD may be used for screening, MS detection must be employed to provide positive confirmation. Zebron MultiResidue columns are well suited for use on all types of detectors. They provide very low bleed levels even at elevated temperatures required to remove matrix contamination during high temperature bake outs. When used in conjunction with a screening method that uses an analyte specific detector such as ECD, Zebron MR- and MR- columns can be a powerful tool in identifying positive samples. 0
11 Confirmation of Multi-Pesticide Mixture by GC/MS The low bleed performance of both Zebron MR- and MR- columns allow them to be used on GC/MS. -, Retention Time Data MR , 9,9 9 Retention time data is available for over 00 pesticides on a Zebron MultiResidue- Column. Please contact your local Phenomenex representative for more details. Column: Zebron MultiResidue- Dimensions: 0 meter x 0. mm x 0. μm Part No.: HG-G0- Injection: Splitless for 0. 0 C, µl Carrier Gas: 0.90 ml/min (constant flow) Oven Program: 0 C for 0. min to 0 0 C/min to 0 C/min to 0 C/min Detector: 0 C -00 amu, , App ID: 0 0, Sample:. Dichlorvos. DEET. EPTC.,-Dichlorobenzoic acid (methyl ester). Butylate. -Nitrophenol (methyl ester). Vernolate. Mevinphos 9. Mevinphos isomer 0. Pebulate. Trichlorfon. Dicamba (methyl ester). Molinate. Tebuthiuron. MCPP (methyl ester). Tetraethyl pyrophosphate (methyl ester). MCPA (methyl ester). Demeton isomer 9. Thionazin 0. Dichloroprop (methyl ester). Propachlor. Cycloate. Ethoprop. Trifluralin. Benefin.,-D (methyl ester). Sulfotep. Naled 9. Chlorpropham 0. Dicrotophos. Phorate. Monocrotophos. Pentachlorophenol (methyl ester). Demeton. Atraton. Profluralin. Prometon. Silvex (methyl ester) 9. Terbufos 0. Dimethoate. Simazine. Propazine. Atrazine. Diazinon. Dioxathion. Terbuthylazine. Fonofos. Pronamide 9. Chloramben (methyl ester) 0.,,-T Methyl ester. Phosphamidon isomer. Disulfoton. Secbumeton. Terbacil. Dinoseb (methyl ester). Dichlofenthion.,-DB (methyl ester). Phosphamidon 9. Chlorpyrifos methyl 0. Alachlor. Bentazon (methyl ester). Ronnel. Prometryn. Methyl parathion. Ametryn. Simetryn. Aspon. Metribuzin 9. Terbutryn 0. Malathion. Fenitrothion. Pichloram (methyl ester). Metolachlor. Chlorpyrifos. DCPA. Bromacil. Fenthion. Trichloronate 9. Triadimeton 0. Isopropalin. Parathion. MGK-. Merphos. Pendimethalin. Diphenamid. MGK- isomer. ofenvinfos. Crotoxyphos 9. Butachlor 90. Stirofos 9. Tokuthion 9. Napropamide 9. Fenamiphos 9. Merphos 9. Oxadiazon 9. Oxyflurofen 9. Carboxin 9. Tricyclazole 99. Acifluorfen 00. Ethion 0. Fensulfothion 0. Carbofenotion 0. Famfur 0. Norflurazon 0. Hexazinone 0. EPN 0. Phosmet 0. Leptophos 09. Azinphos-methyl 0. Fenarimol. Coumaphos. Azinphos-ethyl Phenomenex Tel: 0--0 Fax: 0-- Web:
12 MultiResidue EPA US Method EPA 0 Aroclor 0 MR- Polychlorinated Biphenyls as Aroclors App ID: MR- 0 0 min min App ID: Aroclor 0 MR- MR- App ID: 9 App ID: min min Column: Zebron MultiResidue- Zebron MultiResidue- Dimensions: 0 meter x 0. mm x 0.0 µm 0 meter x 0. mm x 0. µm Part No.: HM-G0-; HM-G0- Injection: Split 0 C, µl Carrier Gas: Oven Program: ml/min (constant pressure) 0 C (hold min) to 00 9 C/min (hold 0 min) Detector: 0 C Sample:. Hexachlorocyclopentadiene. Propaclor Notes: Columns connected using a meter Z-Guard and a Y-splitter How long will columns last? The performance of a GC system will degrade over time requiring inlet maintenance, column trimming, and ultimately the replacement of the GC column. In order to accurately determine what your column lifetime will be it s better to ask yourself the question: What makes your columns fail? Is it bleed, activity, or poor resolution? The better the column performance for that criteria initially will usually lead to better overall performance in the long term. Zebron MultiResidue columns provide the lowest activity, best resolution, and overall most stable performance of any pair of column designed specifically for pesticide testing.
13 US EPA 0A RCP/MCP States of Connecticut and Massachusetts Pesticide List Column: Zebron MultiResidue- Zebron MultiResidue- Dimensions: 0 meter x 0. mm x 0.0 µm 0 meter x 0. mm x 0.0 µm Part No.: HK-G0-; HK-G0- Injection: 0 C, µl Carrier Gas: psi (constant pressure) Oven Program: 0 C for min to C/min (hold min) Detector: 0 C MR App ID: 0 min MR-, App ID: 9 0 min Sample:. Hexachlorocyclopentadiene. Propaclor. Tetrachloro-m-xylene (surr). a-bhc. Hexachlorobenzene. g-bhc (Lindane). b-bhc. Alachlor 9. d-bhc 0. Heptachlor. Aldrin. Heptachlor epoxide. g-chlordane. a-chlordane. Endosulfan I., -DDE. Dieldrin. Endrin 9., -DDD 0. Endosulfan II. Endrin aldehyde., -DDT. Endosulfan sulfate. Methoxychlor. Endrin ketone. Decachlorobiphenyl (surr) This application was supplied courtesy of Keith Aloisa at Phoenix Labs. Phoenix Labs ( is a full service environmental lab that is NELAC accredited and certified in all of New England, New York, and New Jersey. Better resolution. Higher efficiency. Best results I ve ever gotten with any column pair. Do you have a noteworthy application using Zebron GC columns that you would like published? For consideration, please send your chromatogram and a short abstract to skyc@phenomenex.com or fax it to (0) - attn: Sky Countryman. Any type of application is welcome. Phenomenex Tel: 0--0 Fax: 0-- Web:
14 MultiResidue EPA US Method EPA MR- 9 Organophosphorous Pesticides 0, App ID: 0 0 min, MR ,, App ID: 0 0 min Column: Zebron MultiResidue- Zebron MultiResidue- Dimensions: 0 meter x 0. mm x 0.0 µm 0 meter x 0. mm x 0. µm Part No.: HM-G0-; HM-G0- Injection: 0 C, µl Carrier Gas: ml/min (constant flow) Oven Program: 00 C for 0. min to 0 0 C/min to 0 C/min to 0 C Detector: 0 C Notes: Analytes at ppm; Columns connected using a m Z-Guard and a Y-splitter Sample:. Dichlorvos. Mevinphos. Trichlorfon. Tepp. Demeton isomer. Thionazin. Ethoprop. Sulfotep 9. Naled 0. Dicrotophos. Phorate. Monocrotophos. Demeton. Terbuphos. Diazinon. Dimethoate. Fonofos. Phosphamidon isomer 9. Disulfoton 0. Dichlofenthion. Phosphamidon. Chlorpyrifos methyl. Ronnel. Aspon. Methyl parathion. Malathion. Fenitrothion. Chlorpyrifos 9. Fenthion 0. Trichloronate. Parathion. Merphos. Chlorfenvinphos. Crotoxyphos. Stirofos. Tokuthion. Merphos oxide (tribufos). Ethion 9. Fensulfothion 0. Contaminant. Carbofenthion. Famfur. Epn. Phosmet. Leptophos. Azinphos methyl. Azinphos ethyl. Couphomos
15 EPA US Method EPA / Chlorophenoxyacid Herbicides 0 MR min MR- 0 9 App ID: Request Additional EPA Methods 9 Triazine Herbicides. HaloAcetic Acids 0 Aroclors 0 Nitrogen- and Phosphorus- Containing Pesticides 0A Chlorinated Pesticides 9 0 App ID: 0 min Column: Zebron MultiResidue- Zebron MultiResidue- Dimensions: 0 meter x 0. mm x 0.0 μm 0 meter x 0. mm x 0. μm Part No.: HM-G0-; HM-G0- Injection: 0 C, µl Carrier Gas: ml/min (constant flow) Oven Program: 0 C for min to 0 C/min for min to 0 C/min to 0 C Detector: 0 C Sample:. Dalapon.,-Dichlorobenzoic acid. -Nitrophenol. DCAA (surr). Dicamba. MCPP. MCPA. Dichloroprop 9. Contaminant 0.,-D. Pentachlorophenol. DBOB (IS). Silvex. Chloramben.,,-T. Dinoseb.,-DB. Bentazon 9. Picloram 0. DCPA. Acifluorfen Phenomenex Tel: 0--0 Fax: 0-- Web:
16 MultiResidue EPA US Method EPA 0/00 MR- 0 9 Polyaromatic Hydrocarbons,,,, App ID: 0 0 min Tech Tip: Column: Zebron MultiResidue- Dimensions: 0 meter x 0. mm x 0. µm Part No.: HG-G0- Injection: 00 C, µl Carrier Gas: ml/min (constant flow) Oven Program: 0 C for 0. min to C/min to 0 C/min for min Detector: 0 C -00 Sample:. Naphthalene. -Methylnaphthalene. Acenaphthylene. Acenaphthene. Fluorene. Phenanthrene. Anthracene. Fluoranthene 9. Pyrene 0. Benzo[c]fluorene. Benz[a]anthracene. Cyclopenta[c,d]pyrene. Chrysene. Methylchrysene. Benzo[b]fluoranthene. Benzo[j]fluoranthene. Benzo[k]fluoranthene. Benzo[a]pyrene 9. -Methylcholanthrene 0. Dibenz[a,h]acridine. Dibenz[a,j]acridine. Indeno[,,-cd]pyrene. Dibenz[a,h]anthracene. Benzo[g,h,i]perylene. H-Dibenzo[c,g]carbazole. Dibenzo[a,l]pyrene. Dibenzo[a,e]pyrene. Dibenzo[a,i]pyrene 9. Dibenzo[a,h]pyrene Inlet deactivation is critical for obtaining stable calibration curves. Use a liner style that has a taper at the bottom to help focus analytes onto the column. Avoid liners with glass wool because it adds activity. Also remember to change to gold seal regularly when working with Agilent 90
17 DIN Method : Polychlorinated Biphenyls Separation Resolving Critical Isomers Polychlorinated Biphenyls (PCBs) are a class of priority environmental pollutants that have been identified for international regulation. The similarity in structure and polarity makes the resolution of certain isomers challenging on standard phases. German law requires separation of specific PCB congeners under DIN Method. The unique selectivity offered by Zebron MulitResidue columns makes them a versatile solution for many applications outside of pesticide analysis. Both the MR- and the MR- columns provide resolution of all the required PCB congeners in less than 0 minutes, allowing for simultaneous confirmation of each sample. MR min App ID: Sample: MR- 0. TCMX. BZ#. BZ#. BZ#. BZ# 0. BZ#. BZ#. BZ# 9. BZ# 0. BZ#. BZ# 0. BZ#. BZ#. BZ#. BZ#. BZ#. BZ# 0. BZ# 0 9. BZ# 9 0. BZ# 9. DCB 9, min App ID: Column: Zebron MultiResidue- Zebron MultiResidue- Dimensions: 0 meter x 0. mm x 0.0 μm 0 meter x 0. mm x 0. μm Part No.: HM-G0-; HM-G0- Injection: 0 C, µl Carrier Gas: ml/min (constant flow) Oven Program: 00 C for 0. min to 00 C/min to 0 C/min for min Detector: 0 C Phenomenex Tel: 0--0 Fax: 0-- Web:
18 MultiResidue Ordering Information Choose the Best Column Set for Your Needs We know every lab is different and we want to help make choosing the right GC column easy. Zebron MultiResidue columns are available in a variety of formats to meet your lab s needs. 0. mm ID Provides the overall best resolution, lowest bleed, and greatest sensitivity. Recommended when using GC/MS or when needing the lowest detection levels possible. Does not handle high level samples well, column lifetime might be reduced. Resolution Stability Sensitivity Bleed Low High 0. mm ID Good compromise between resolution and column stability. Recommended when working with dual column setups where high level samples will be encountered. Works well on newer MS systems. High flow rates decrease residence time in the inlet. Low Resolution Stability Sensitivity Bleed High 0. mm ID Recommended when working with highly contaminated samples. Good for screening instruments. Resolution and sensitivity will be slightly reduced when compared to 0. or 0. mm ID columns. However, Zebron MultiResidue phases have very high selectivity for pesticides. Thus, resolution will be greater than other phases recommended for this work. Low Resolution Stability Sensitivity Bleed High Column Installs This End Phenomenex Recommended Liners Description GC Model No. Dimensions ID x L x OD (mm) Part No. Unit Price Split / Splitless with Single Taper 0/90/90 x. x. AG0- AG0-0 /pk /pk $ 9 Single Taper Direct Connect with Side Hole (top) 0/90/90 x. x. AG0-0 /pk Single Taper Direct Connect with Side Hole (bottom) 0/90/90 x. x. AG0- /pk
19 Zebron MultiResidue Zebron MultiResidue ID (mm) Temp. Limits C df (µm) Part No. df (µm) Part No. Price 0-Meter to 0/0 0. HG-G0-0.0 HG-G0-0 $ to 0/0 0.0 HM-G0-0. HM-G to 0/0 0.0 HK-G0-0.0 HK-G0- Zebron MultiResidue Column Kits 0. mm ID Kit KG0- $,0 SAVE $ 9 Description Dimension Part No. Price MultiResidue- 0 meter x 0. mm x 0. µm df HG-G0- $ 9 MultiResidue- 0 meter x 0. mm x 0.0 µm df HG-G0-0 9 Z-Guard meters x 0. mm AG-G GZ0 0 Universal Capillary Column Y-connector, Borosilicate AG0-0. mm ID Kit KG0- $, SAVE $ Description Dimension Part No. Price MultiResidue- 0 meter x 0. mm x 0.0 µm df HM-G0- $ MultiResidue- 0 meter x 0. mm x 0. µm df HM-G0- Z-Guard meters x 0. mm AM-G GZ0 90 Universal Capillary Column Y-connector, Borosilicate AG0-0. mm ID Kit KG0-9 $,0 SAVE $ Description Dimension Part No. Price MultiResidue- 0 meter x 0. mm x 0.0 µm df HK-G0- $ MultiResidue- 0 meter x 0. mm x 0.0 µm df HK-G0- Z-Guard meter x 0. mm AK-G GZ0 0 Universal Capillary Column Y-connector, Borosilicate AG0- Gold Inlet Base Seals Standard, Single Groove for Splitless Applications, 0. mm dia. Inlet Hole Part No. Description Similar to Mfr. No.* Unit Price AG0- AG0-9 Gold Inlet Base Seal, splitless (single groove) Gold Inlet Base Seal, splitless (single groove) Replacement Inlet Seal Washers 0-0 /pk $ 0-0 0/pk 9 Part No. Description Similar to Mfr. No.* Unit Price AG0- Inlet Seal Washers, for Agilent GC injection port Inlet seal washers are sold separately from inlet base seals. * Similar to but not always an exact equivalent to the original manufacturer s product. 0-9 /pk $ Prices are in US dollars. If you wish to buy in Canadian dollars, multiply US dollar prices by.. Receive your invoice in Canadian or US dollars. It s your choice. Your Canadian cheque is accepted. Phenomenex Tel: 0--0 Fax: 0-- Web: 9
20 Phenomenex: Years of Progress Since its founding in 9, Phenomenex has been dedicated to the development, manufacturing and supply of products and accessories for the separation, analysis and purification of chemicals and biochemicals. Offering the widest selection of chromatography columns and consumables from a single supplier worldwide, Phenomenex s objective is to provide the very best product for every application. The company has subsidiaries and leading market positions in the USA, Canada, United Kingdom, Germany, New Zealand, Australia, France, Ireland, Denmark, Italy, and many other countries. Our vast network of well-trained partners and distributors enables Phenomenex to successfully supply and support the work of scientists in more than 0 countries around the world. Zebron GC Columns In 99, Phenomenex diversified its business into the field of Gas Chromatography. It brought together chemists with more than years of GC column manufacturing knowledge from other major names in the GC column industry. The goal was simple: make a better GC column. Phenomenex has rapidly grown to be one of the leaders in GC column technology and already produces a significant portion of the high performance capillary columns used worldwide. The Best Guarantee in the Industry If Zebron does not provide you with better separation as compared to any other GC column of the same phase and comparable dimensions, send in your comparative data within days and keep your Zebron column for FREE! Zebron and MultiResidue are trademarks of Phenomenex, Inc. Agilent is a registered trademark of Hewlett Packard. Thermo is a registered trademark of Thermo Electron Corporation. Finnigan, Trace, and DSQ are trademarks of Thermo Electron Corporation. Phenomenex is in no way affiliated with Agilent, Hewlett Packard, or Thermo Electron Corporation. The opinions stated herein are solely those of the speaker and not necessarily those of any company or organization. 00 Phenomenex, Inc. All rights reserved. Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department by telephone, fax or international@phenomenex.com. mail: tel.: fax: USA Madrid Ave. Torrance, CA USA (0) -0 (0) - info@ phenomenex.com Puerto Rico Sierra Morena, Suite #0 San Juan, Puerto Rico 009 (00) -HPLC (0) - info@ phenomenex.com Canada Madrid Ave. Torrance, CA USA (00) - (0) - info@ phenomenex.com France Parc des Grillons, Bat. 0 Route de Sartrouville Le Pecq Cedex France franceinfo@ phenomenex.com United Kingdom Queens Avenue, Hurdsfield Ind. Est., Macclesfield, Cheshire SK0 BN, UK ukinfo@ phenomenex.com mail: tel.: fax: Ireland Queens Avenue, Hurdsfield Ind. Est., Macclesfield, Cheshire SK0 BN, UK eireinfo@ phenomenex.com Germany Zeppelinstr. Aschaffenburg Germany anfrage@ phenomenex.com New Zealand P O Box -0 Milford 0 North Shore City New Zealand info@ phenomenex.co.nz Australia PO Box 0 Lane Cove, NSW 0 Australia info@ phenomenex.com.au _U _U
Zebron MultiResidue GC Columns
Zebron MultiResidue GC Columns A New Generation of Columns for Pesticide Analysis MultiResidue Optimized for pesticide, herbicide and insecticide analysis The use of many pesticides has been limited or
More informationMulti-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms
Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Application Note Author Laura Provoost Agilent Technologies, Inc. Introduction In multi-residue analysis different groups
More informationEvaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns
Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP/DB-CLP GC Columns Application Note Environmental Authors Doris Smith and Ken Lynam Agilent Technologies, Inc. Abstract The
More informationRtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance
Columns Reduce Analysis Time; Reduce System Maintenance 0 YEARS Turning Visions into Reality www.restek.com 00-- --00 and Fused Silica Columns Detect and confirm 0 common organochlorine pesticides simultaneously.
More informationDeveloping Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014
Developing Large Volume Injection (LVI) in Split / Splitless Inlets Philip J. Koerner Phenomenex Inc. NEMC 2014 Goal To produce a method that provides the largest response of analytes that will produce
More informationFast, Accurate Environmental Testing
GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring Pesticides Diesel Range Organics Semivolatiles Dioxane And more.. www.phenomenex.com/environmental Semi-Volatile Organic
More informationDetermination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode
PO-CON1610E Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode Pittcon 2016 1110-2 Brahm Prakash, William Lipps, Di Wang, Shilpi Chopra, Nicole
More informationCertificate of Analysis
Certificate of Analysis 2139 Certificate Number: 13-92896 Date: 27/11/2013 Client: Stainton Quarry Stainton Quarry Stainton Barnard Castle DL12 8RB Our Reference: 13-92896 Client Reference: Description:
More informationQuantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor
Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor Application Note Pesticides Authors Charlie Spanjers and Paul Dauenhauer University of Minnesota, Twin Cities
More information4. Place a 20 ml VOA vial in position 1 of the tray. 5. Place a 6 ml C18-E cartridge in position 1 of the carousel.
Increase Throughput and Recoveries for EPA Method 508.1 with Automated Extraction using Strata C18-E SPE Cartridges and Zebron ZB-MultiResidue GC Columns Kali Tudela Phenomenex, Inc., 411 Madrid Ave.,
More informationNew Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories
New Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories Ken Lynam CSD Application Chemist Presentation Outline DB-UI 8270D columns
More informationOptimizing GC Parameters for Faster Separations with Conventional Instrumentation
Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Anila I. Khan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 243 Key Words TraceGOLD fast GC analysis
More informationNew ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column
New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column The World's First Non-metal 5% Phenyl Phase GC Column Rated to 430 C * Specially processed for thermal stability up to 430 C A true
More informationHigh Throughput Multi-Residue Screening of Drinking Water using the SPE-DEX~ and Pegasus GC-TOF-MS
Application Note No. 098 High Throughput Multi-Residue Screening of Drinking Water using the SPE-DEX~ and Pegasus GC-TOF-MS Steve Scott, Thames Water, Reading, UK Diane Turner. Introduction In cases of
More informationOrganochlorine Pesticides by GCxGC-ECD
Organochlorine Pesticides by GCxGC-ECD LECO Corporation; Saint Joseph, Michigan USA Key Words: GCxGC-ECD, Environmental, Quantification 1. Introduction United States Environmental Protection Agency Method
More informationPAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices
PAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices Food Quality and Environmental Author Ken Lynam Agilent Technologies, Inc. 280 Centerville Road Wilmington, DE 19808 Abstract
More informationAnalysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes
Priority Analysis LC GC Core-Shell Technology GC Columns Kinetex PAH Expanded resolution with chemical selectivity specifically for PAHs Increased throughput and sensitivity with core-shell technology
More informationChallenging Pesticide Analysis Using an Agilent J&W DB-35ms Ultra Inert GC Column
Challenging Pesticide Analysis Using an Agilent J&W DB-ms Ultra Inert GC Column Application Note Food Analysis and Environmental Authors Ken Lynam and Doris Smith Agilent Technologies, Inc. 80 Centerville
More informationIntroduction to Gas Chromatography
Introduction to Gas Chromatography 31-1 Objectives To know what is chromatography To understand the mechanism of compound separation To know the basic of gas chromatography system 31-2 Chromatography Definition
More informationMULTIRESIDUE ANALYSIS OF PRIORITY POLLUTANTS IN SURFACE WATERS USING EXACT MASS GC-TOF MS
MULTIRESIDUE ANALYSIS OF PRIORITY POLLUTANTS IN SURFACE WATERS USING EXACT MASS GC-TOF MS Peter Hancock and Keith Worrall Waters Corporation, Manchester M22 5PP, UK INTRODUCTION The Dangerous Substances
More informationenvironmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)
environmental #59120 Applications note Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs) Polychlorinated biphenyls (PCBs) are
More informationSUPELCO. Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns
Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns L.M. Sidisky, Yizeng Ni, Greg Baney, Rodney George, Katherine K. Stenerson 01-0026 T401044 CFK Discussion
More informationSelection of a Capillary
Selection of a Capillary GC Column - Series 3 Mark Sinnott Application Engineer March 19, 2009 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector
More informationSelection of a Capillary GC Column
Selection of a Capillary GC Column Mark Sinnott Application Engineer March 13, 2008 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer
More informationPesticides Analysis Using the Agilent 5977A Series GC/MSD
Pesticides Analysis Using the Agilent 5977A Series GC/MSD Application Note Food Testing and Agriculture Authors Jia-jia Wu and Wen-wen Wang Agilent Technologies Co. Ltd (China) Beijing, People s Republic
More informationRely on Rxi -PAH Columns
Rely on Rxi -PAH Columns to Ensure Successful Polycyclic Aromatic Hydrocarbon (PAH) Analysis Optimized Efficiency, Selectivity, and Robustness Let You: Report accurate results with speed and confidence.
More informationMETHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS
METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS 1.0 SCOPE AND APPLICATION 1.1 Method 8100 is used to determine the concentration of certain polynuclear aromatic hydrocarbons (PAH). Table 1 indicates compounds
More informationFast and Accurate Analysis of PBDEs in a Single Run, Including
Fast and Accurate Analysis of PBDEs in a Single Run, Including Kory Kelly, Adam Endeman, and Matthew Trass Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA PO14700713_2 PO14400613_W_2 Abstract
More informationU.S. EPA Method 8270 for multicomponent analyte determination
ENVIRONMENTAL application note U.S. EPA Method 8270 for multicomponent analyte determination Elaine A. LeMoine and Herman Hoberecht Introduction Multicomponent analytes are compounds that yield several
More informationFast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209
Fast and Accurate Analysis of PBDEs in a Single Run, Including Kory Kelly, Xianrong (Jenny) Wei, and Matthew Trass Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA PO16570913_W_2 PO14400613_W_2
More informationFast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application
Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application Environmental Analysis Author Mike Szelewski Agilent Technologies, Inc. 2850 Centerville
More informationSensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS
Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS Dominic Roberts, 1 Sara Stead, 1 and Jennifer A. Burgess 2 1 Waters Corporation, Manchester, UK 2 Waters Corporation,
More informationThe performance you demand... the service you deserve... from the company you trust. Updated with:
Equity Capillary GC Columns The performance you demand... the service you deserve... from the company you trust. Updated with: NEW Equity-0 columns New Applications sigma-aldrich.com/supelco The performance
More informationThe Suite for Environmental GC Analysis
The Suite for Environmental GC Analysis SGE Environmental GC Columns Performance Selectivity Delivery Promise www.sge.com SGE Environmental GC Columns The Suite for Environmental GC Analysis SGE GC Columns
More informationLow Bleed Stationary Phases for Gas Chromatography
Low Bleed Stationary Phases for Gas Chromatography Slide 4 Advantages of Low Bleed Phase Lower bleed compared to standard phases Better signal to noise (sensitivity) Higher upper temperature - shorter
More informationThe Pulsed Flame Photometric Detector for analysis of phosphorus pesticides in wastewater and food commodities
The Pulsed Flame Photometric Detector for analysis of phosphorus pesticides in wastewater and food commodities Application Note Environmental Authors Agilent Technologies, Inc. Introduction Twenty-eight
More informationQuEChERS Pesticide Analysis for Fresh Produce*
QuEChERS Pesticide Analysis for Fresh Produce* UCT Products: ECMSSC50CTFS-MP (6 grams MgSO 4, 1.5 g NaCl) ECQUEU1115CT (1.2 grams MgSO 4, 0.4 g PSA, 0.4 g GCB) ECMSC1850CT (1500 mg MgSO 4, 500 mg endcapped
More informationAccelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil
Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Che Jinshui, 1 Deng Guifeng, 1 Liang Lina, 1 and Aaron Kettle, 2 1 Thermo Fisher Scientific (China)
More informationRugged GC/MS/MS Pesticide Residue Analysis Fulfilling the USDA Pesticide Data Program (PDP) Requirements
Rugged GC/MS/MS Pesticide Residue Analysis Fulfilling the USDA Pesticide Data Program (PDP) Requirements Application Note Food Safety Author Katerina Mastovska Excellcon International LLC Plymouth Meeting,
More informationPractical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software
Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software GC Columns and Consumables Mark Sinnott Application Engineer January 8 th, 2008 Page 1 Questions to Ask
More informationAnalysis of Pesticides and Contaminants using HS-SPME-GC/MS and DRS Detection. Blair Surridge, Tyler Dyer, Rene Bilideau, Paloma Bertolin Presoti
Analysis of Pesticides and Contaminants using HS-SPME-GC/MS and DRS Detection Blair Surridge, Tyler Dyer, Rene Bilideau, Paloma Bertolin Presoti Applied Research at Camosun College Provides funding to
More informationUnderstanding Gas Chromatography
Understanding Gas Chromatography What is Really Going on Inside the Box? Simon Jones GC Applications Engineer Page 1 Group/Presentation Title Month ##, 200X ?? K? Page 2 Typical GC System Gas supply Injector
More informationTrim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ
Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ Courtney Milner, Ph.D. Agilent Technologies Santa Clara, CA ASMS 2018 VIP Session 1 Agenda Pesticide analysis trends Targeted
More informationThe Analysis of Organophosphate Pesticides by LC/MS Application
The Analysis of Organophosphate Pesticides by LC/MS Application LC-MS Authors Paul Zavitsanos Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808-1610 USA Paul Yang MOE Ontario Canada
More informationGC/Q-TOF MS Surveillance of Pesticides in Food
GC/Q-TOF MS Surveillance of Pesticides in Food A Combined Workflow for Quantitative and Qualitative Screening of Pesticides using the Agilent MassHunter GC/Q TOF Pesticide Personal Compound Database and
More informationThe Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products
The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products Bruno Veyrand, Aline Brosseaud, Philippe Marchand, Fabrice Monteau, François Andre,
More informationGC AND GC/MS. Your Essential Resource for Columns & Supplies
GC AND GC/MS Your Essential Resource for Columns & Supplies GC AppLICATIonS GC Applications Industry-specific applications from your partner in chromatography With over 0 years of chromatography expertise,
More informationKatherine K. Stenerson, Michael Ye, Michael Halpenny, Olga Shimelis, and Leonard M. Sidisky. Supelco, Div. of Sigma-Aldrich Bellefonte, PA USA
New Analytical Tools for the Determination of Persistent Organic Pollutants (POPs) in Fatty Food and Beverage Matrices Using QuEChERS Extraction/Cleanup and Gas Chromatography (GC) Analysis Katherine K.
More informationDetermination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS
Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS UCT Part Numbers: ECQUUS2-MP (4 g of muffled anh. MgSO 4 and 2 g of NaCl) ECPAHFR50CT (50 ml centrifuge tubes, PAHs removed)
More informationThe Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane
The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane Jarl Snider, D. J. Hotnisky, Kristi Sellers, Dinesh V. Patwardhan Ph. D. Restek Corporation www.restekcorp.com
More informationGC Analysis of Polybrominated Flame Retardants Application
GC Analysis of Polybrominated Flame Retardants Application Environmental Authors Eberhardt Kuhn, Jason Ellis Agilent Technologies, Inc. 91 Blue Ravine Rd, Folsom, CA 9563 USA Steve Wilbur Agilent Technologies,
More informationANALYTICAL REPORT. Attn: Dan Spector
ANALYTICAL REPORT TestAmerica Laboratories, Inc. Benjamin Road Suite 0 Tampa, FL Tel: ()- TestAmerica Job I: 0-- Client Revision: For: Langan Engineering & Environmental Srvcs 0 NW th Court Suite 00 Miami
More informationApplication Note. Abstract. Authors. Environmental
GC/MS Analysis of European Union (EU) Priority Polycyclic Aromatic Hydrocarbons (PAHs) using an Agilent J&W DB-EUPAH GC Column with a Column Performance Comparison Application Note Environmental Authors
More informationMeeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS
Application Note # CA 284780 Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Abstract The analysis of semi-volatile organic compounds
More informationDetermination of 24 PAHs in Drinking Water
Determination of 24 PAHs in Drinking Water Application Note Food Testing and Agriculture Authors M.C. Díaz Ramos, A. Suárez, A. Rúbies, and R. Companyó Laboratori de l Agencia de Salut Publica de Barcelona
More informationShould you have any questions, please contact our office at (813)
October 14, 2013 Comprehensive Engineering Services, Inc. 201 S. Orange Avenue, Suite 1300 Orlando, Florida 32801 Attn: RE: Mr. John F. Petrosillo, P.E. Project Manager Draft Level II Field Screening Report
More informationNon-Potable Water A2LA Certificate
COLOR Color Biochemical Oxygen Demand (BOD); Carbonaceous DEMAND BOD; Chemical Oxygen Demand (COD); Total Organic Carbon (TOC) HEXAVALENT CHROMIUM INORGANIC NUTRIENTS LOW-LEVEL MERCURY METALS I & II METALS
More informationHighly Sensitive and Rugged GC/MS/MS Tool
Highly Sensitive and Rugged GC/MS/MS Tool For Pesticide Multiresidue Analysis in Food Samples Agilent 7 Series Triple Quadrupole GC/MS. The world s first MS/MS designed specifically for GC Analysis Introduction
More informationApplication Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS
Application Note #1820230 Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS GC-MS Introduction USEPA Method 8270 [1] for semivolatiles is is used by by laboratories to measure
More informationA Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)
Application Note 19010803 A Newly Approved ASTM Standard For Analysis of in Using a Pulsed Flame Photometric Detector (PFPD) Keywords ASTM Standard D4735-96 FPD Flame Photometric Detector Model 5380 PFPD
More information2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva
2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva Craig Dufresne and Kevin McHale, Content Creators The world leader in serving science The Whole Workflow Efficiency in sample
More informationApplication Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution
Application Note Abstract Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution Page 1 Polycyclic Aromatic Hydrocarbons (PAHs) are a large group of organic compounds
More informationAuthor. Abstract. Introduction
Improved Performance for the Analysis of Aromatics in Gasoline by ASTM Method D5769 Using the Agilent 5973 inert Gas Chromatography/Mass Spectrometry System Application Author James D. McCurry Agilent
More informationAccurate, Reproducible Results for Environmental Methods with Zebron GC Columns
Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns BUY NOW AND SAVE! Length Sale Price* 10-15 meter $ 199 30 meter $ 399 60 meter $ 599 *Offer valid only for addressee, limit
More informationCHROMATOGRAPHIC TECHNIQUES FOR CONTAMINANTS DETERMINATIONS IN HONEY
UNIVERSITY OF AGRICULTURAL SCIENCES AND VETERINARY MEDICINE CLUJ-NAPOCA DOCTORAL SCHOOL FACULTY OF AGRICULTURAL SCIENCES AND BIOTECHNOLOGIES Chim. VICTORIŢA BURIAN (BONTA) CHROMATOGRAPHIC TECHNIQUES FOR
More informationENVIRONMENTAL analysis
ENVIRONMENTAL analysis Analyzing Wastewater Effluents for PAH s and PBDE s Using the Agilent 7000 Triple Quadrupole GC/MS Solutions for Your Analytical Business Markets and Applications Programs Authors
More informationPOTENTIAL VAPOR INTRUSION ENVIRONMENTAL
POTENTIAL VAPOR INTRUSION ENVIRONMENTAL INVESTIGATION INVESTIGATION FOR: Michael Lee Bronxville School District 77 Pondfield Road Bronxville, NY 0708 SITE INVESTIGATED: Bronxville Elementary School Parking
More informationMETHOD 8141B ORGANOPHOSPHORUS COMPOUNDS BY GAS CHROMATOGRAPHY
METHOD 8141B ORGANOPHOSPHORUS COMPOUNDS BY GAS CHROMATOGRAPHY 1.0 SCOPE AND APPLICATION 1.1 This method provides procedures for the gas chromatographic (GC) determination of organophosphorus (OP) compounds.
More informationIdentifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application
Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application Food Safety, Environmental Authors Chin-Kai Meng and Bruce Quimby Agilent Technologies, Inc. 2850 Centerville
More informationIdentification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS
Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7B Triple Quadrupole GC/MS Application Note Authors Dale R. Walker and Fred Feyerherm Agilent Technologies, Inc.
More informationAnalysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application
Analysis of Trace (mg/kg) Thiophene in Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Petrochemical Authors James D. McCurry and Bruce D. Quimby Agilent Technologies
More informationDETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT
DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT Peter Hancock 1, Mike Hetmanski 2 and Richard J. Fussell 2 1 Waters Corporation, Atlas Park, Simonsway, Manchester M22 5PP, UK 2 Central
More informationAdvantages of Reversed Sandwich Injection for Pesticide Residue Analysis
Advantages of Reversed Sandwich Injection for Pesticide Residue Analysis Application Note Author Jessica Westland Agilent Technologies, Inc. Abstract This application note demonstrates the use of the Agilent
More informationKSA Environmental Laboratory Inc.
February 26, 07 KSA Environmental Laboratory Inc. Hydrologic Associates - Miami Attn: Brad Waller 8925 S.W. 148th Street Suite 212 Miami, FL 33176 RE: Parkland KSA Workorder: Q0012 Dear Brad Waller, Enclosed
More informationFaster Semivolatiles Analysis with a Scaled- Down Method and GC Accelerator Kit
Faster Semivolatiles Analysis with a Scaled- Down Method and GC Accelerator Kit Analysis times for semivolatile compounds can limit sample throughput and decrease overall lab productivity. You can significantly
More informationImproved GC/MS Analysis of Tomato Pesticides with Agilent Deactivated Silica Tubing
Improved GC/MS Analysis of Tomato Pesticides with Agilent Deactivated Silica Tubing Agilent Ultimate Plus Deactivated Fused Silica Tubing for Guard Columns Application Note Food Safety Authors Yun Zou
More informationThis project has been funded with support from the European Commission. This publication reflects the views only of the authors, and the Commission
This project has been funded with support from the European Commission. This publication reflects the views only of the authors, and the Commission cannot be held responsible for any use which may be made
More informationAnalysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404
Gas Chromatograph Mass Spectrometer No. GCMS-1404 Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030 Introduction Contamination of consumer products with pesticides is a growing concern
More informationEAA STAFF ATTACHMENT 13 DECEMBER Appendix D Analytical Data Validation Discussion
Appendix D Analytical Data Validation Discussion Introduction This appendix provides an overview of the EAA s post analyses review of the TestAmerica analytical data set. In general, the data are considered
More informationAnalysis of Semivolatile Organic Compounds Using the Agilent Intuvo 9000 Gas Chromatograph
Analysis of Semivolatile Organic Compounds Using the Agilent Intuvo 9 Gas Chromatograph Application Note Author Matthew Giardina, Ph.D., Applications Chemist, Gas Phase Separations Division, Agilent Technologies,
More informationMass Spectral Studies of Polypropylene Chromatographic Well Plates
Mass Spectral Studies of Polypropylene Chromatographic Well Plates Brian King, Thermo Fisher Scientific, Runcorn, Cheshire, UK Detlev Lennartz, Thermo Fisher Scientific, Langerwehe, Germany White Paper
More informationAnalysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS
PO-CONE Analysis of Pesticides in Baby Foods Using a Pittcon 01 -P Laura Chambers, Richard Whitney, Ph.D., Nicole M. Lock, Zhuangzhi Max Wang, Ph.D., Clifford M. Taylor; Shimadzu Scientific Instruments,
More informationA novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins
TECHNICAL NOTE 39 A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins Author Cristian Cojocariu Thermo Fisher Scientific, Runcorn,
More informationThree-Fold Increase in Productivity for Pesticide Residue Analysis in Baby Food Using Fast Triple Quadrupole GC-MS/MS
Three-Fold Increase in Productivity for Pesticide Residue Analysis in Baby Food Using Fast Triple Quadrupole GC-MS/MS Cristian Cojocariu,1 Michael T. Hetmanski,2 Paul Silcock,1 and Richard J. Fussell2
More informationAgilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings
Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings Technical Overview Introduction Modern GC and GC/MS instruments are important analytical tools for accurate and
More informationIntroduction to Capillary GC
?? Kβ? Page 1 Typical GC System Gas supply Injector Detector Data handling GAS Column Oven Page 2 CARRIER GAS Carries the solutes down the column Selection and velocity influences efficiency and retention
More informationHigh Efficiency, Broad Scope Screening of Pesticides Using Gas Chromatography High Resolution Orbitrap Mass Spectrometry
High Efficiency, Broad Scope Screening of Pesticides Using Gas Chromatography High Resolution Orbitrap Mass Spectrometry Dominic Roberts,1 Hans Mol,2 Marc Tienstra,2 Cristian Cojocariu,1 and Paul Silcock1
More informationThermo Scientific Accucore XL HPLC Columns. Technical Manual
Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users
More informationApplication Note No Introduction. DMI Instrumentation. DMI Method. DMI for Lettuce and Pea Extracts. Lettuce results
Application Note No. 082 Multi-Residue Analysis of Pesticides in Samples of Lettuce and Peas Using Large Volume-Difficult Matrix Introduction-Gas Chromatography-Mass Spectrometry (LV-DMI-GC-MS) Richard
More informationPractical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software
Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software High Efficiency GC Columns Page 1 Variables for Shortening Run Times Stationary Phase Shorten Column Length
More informationCharacterization of Carbon SPE for the Extraction of Polar Analytes
Characterization of Carbon SPE for the Extraction of Polar Analytes Cory Szafranski, Lydia Nolan, and William R. Betz Supelco, Supelco Park, Bellefonte, PA 16823 USA 1997 Sigma-Aldrich Co. T497277 BNG
More informationANALYTICAL REPORT. Attn: Steve Johnson
ANALYTICAL REPORT TestAmerica Laboratories, Inc. N. Padre Island rive Corpus Christi, TX 0 Tel: ()- TestAmerica Job I: 0-00- Client For: Edwards Aquifer Authority North St. Mary's Street San Antonio, Texas
More informationYokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan.
Determination of organochlorine pesticides in river water by gas chromatography-negative-ion chemical-ionization mass spectrometry using large volume injection Sadao Nakamura,* Takashi Yamagami and Shigeki
More informationMETHOD 507 DETERMINATION OF NITROGEN - AND PHOSPHORUS-CONTAINING PESTICIDES IN WATER BY GAS CHROMATOGRAPHY WITH A NITROGEN-PHOSPHORUS DETECTOR
METHOD 507 DETERMINATION OF NITROGEN - AND PHOSPHORUS-CONTAINING PESTICIDES IN WATER BY GAS CHROMATOGRAPHY WITH A NITROGEN-PHOSPHORUS DETECTOR Revision 2.1 Edited by J.W. Munch (1995) T. Engel (Battelle
More informationSemivolatile Organic Reference Materials
At-a-Glance Product Information from Restek US Environmental Protection Agency (EPA) Method 8270D outlines the analysis of semivolatile organic pollutants in solid waste, soil, water, and air matrices
More informationGet Selective. By Jaap de Zeeuw
34 Get Selective Modern narrow bore columns have made chromatographers lazy when it comes to stationary phase selection. Here s how getting back to basics in gas chromatography by using selectivity can
More informationSecrets of GC Column Dimensions
Secrets of GC Column Dimensions GC Columns and Consumables Simon Jones Application Engineer May 20, 2008 Slide 1 Secrets of GC Column Dimensions Do I have the right column phase? Resolution Equation Changes
More informationMETHOD 3600C CLEANUP
METHOD 3600C CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3600 provides general guidance on selection of cleanup methods that are appropriate for the target analytes of interest. Cleanup methods are applied
More informationRoutine-grade robustness with the Advanced Electron Ionization source: confirmation of contaminants in food products at trace levels by GC-MS/MS
TECHNICAL NOTE 10605 Routine-grade robustness with the Advanced Electron Ionization source: confirmation of contaminants in food products at trace levels by GC-MS/MS Authors Richard Law, 1 Paul Silcock,
More informationActivity in the FID Detection Port: A Big Problem if Underestimated
Activity in the FID Detection Port: A Big Problem if Underestimated Jaap de Zeeuw, Restek Corporation, Middelburg, The Netherlands It is commonly known in gas chromatography, that many problems can be
More information