The EUROBALL neutron wall design and performance tests of neutron detectors

Size: px
Start display at page:

Download "The EUROBALL neutron wall design and performance tests of neutron detectors"

Transcription

1 Nuclear Instruments and Methods in Physics Research A 421 (1999) The EUROBALL neutron wall design and performance tests of neutron detectors O. Skeppstedt, H.A. Roth, L. Lindström, R. Wadsworth, I. Hibbert, N. Kelsall, D. Jenkins, H. Grawe, M.Go rska, M. Moszyński *, Z. Sujkowski, D. Wolski, M. Kapusta, M. Hellström, S. Kalogeropoulos, D. Oner, A. Johnson, J. Cederkäll, W. Klamra, J. Nyberg, M. Weiszflog, J. Kay, R. Griffiths, J. Garces Narro, C. Pearson, J. Eberth Department of Experimental Physics, Chalmers University of Technology and Go( teborg University, S Go( teborg, Sweden Department of Physics, University of York, Heslington, York YO1 5DD, UK GSI, D Darmstadt, Germany Soltan Institute for Nuclear Studies, Department of Nuclear Electronics, PL Otwock S! wierk, Poland Heavy Ion Laboratory Warsaw University, PL Warsaw, Poland Division of Cosmic and Subatomic Physics, Lund University, S Lund, Sweden Royal Institute of Technology, Physics Department, S Stockholm, Sweden The Svedberg Laboratory, Uppsala University, S Uppsala, Sweden CCLRC Daresbury Laboratory, Daresbury, Warrington, Cheshire WA4 4AD, UK Physics Department, University of Surrey, Guildford GU2 5XH, UK IKP Universita( tzuko( ln, D Ko( ln, Germany Received 21 August 1998; received in revised form 15 September 1998 Abstract The mechanical design of the EUROBALL neutron wall and neutron detectors, and their performance measured with a Cm fission source are described. The array consists of 15 pseudohexaconical detector units subdivided into three, 149 mm high, hermetically separated segments and a smaller central pentagonal unit subdivided into five segments. The detectors are filled with Bicron BC501A liquid scintillator. Each section of the hexaconical detectors is viewed by a 130 mm diameter Philips XP4512PA photomultiplier while the sections of pentagonal detectors are viewed by Philips XP4312B PMTs. The tests of n γ discrimination performed by zero-crossing and time-of-flight methods show a full separation of γ- and neutron events down to 50 kev recoil electron energy. These tests demonstrate the excellent timing properties of the detectors and an average time resolution of 1.56 ns. The factors determining the efficiency of neutron detectors are discussed. The total efficiency for the full array for a symmetric fusion-evaporation reaction is predicted to be Elsevier Science B.V. All rights reserved. Keywords: EUROBALL neutron wall; Neutron detectors; n γ discrimination; Time-of-flight * Corresponding author. Tel.: # ; fax: # ; marek@ipj.gov.pl /99/$ see front matter 1999 Elsevier Science B.V. All rights reserved. PII: S ( 9 8 ) X

2 532 O$. Skeppstedt et al./nucl. Instr. and Meth. in Phys. Res. A 421 (1999) Introduction The combination of detectors for neutron and light charged particle detection with efficient γ- detector arrays has been proven to be a powerful tool in the spectroscopy of exotic neutron deficient nuclei close to N"Z and the proton dripline [1 3,17]. The application of a filter detector for the identification and suppression of events from the dominant charged particle evaporation channels is an essential prerequisite for the successful spectroscopy of proton rich nuclei. Future applications of such a filter device, may comprise combination with recoil detection, charged particle decay studies and μs-ms tagging devices for γ-ray spectroscopy at and beyond the proton dripline. The excellent timing characteristics of the liquid scintillators and their efficiency for γ-rays provide a good time reference which is important for example, in DC beam experiments. The leading design criteria for ancillary detectors are in general: large efficiency, high granularity and minimum interference with γ ray detection. The relevant specifications for the EUROBALL [4] neutron detector array are as follows: performance as measured with a Cm fission source in laboratory conditions. The performance tests were begun with a measurement of the number of photoelectrons produced in the PMT by γ-rays detected in the scintillator cell. This allows a comparative check of the quality of the assembled detectors to be made. Next, a full test of n γ separation by the Z/C pulse-shape discrimination and time-of-flight was carried out for some detectors. In the last section of the paper various factors determining the efficiency of the EUROBALL neutron wall are discussed. 2. Detector design The geometry of the Ge cluster/bgo shield end cap of EUROBALL was chosen to ensure optimum compatibility with the EUROBALL mechanical design. The array consists of 15 pseudohexaconical detector units in two rings (Fig. 1b) and a central pentagonal unit. Each hexagonal unit is subdivided Intrinsic efficiency for evaporation neutrons ε 50%, Ω"1π, resulting in a typical total efficiency ε "25 30%, dependent on reaction kinematics. High granularity to limit count rate per detector and n γ double hits. Minimum cross talk from neutron scattering, obtained by suppressing next neighbour hits and using time analysis of neutron events of fold M 2. Combination of zero/crossover (Z/C) pulse shape and time-of-flight (TOF) analysis. Minimum interference with γ-ray detection. Cluster cap design of EUROBALL. Some of the above requirements are related to the mechanical design of the neutron wall while others are determined by the quality of the detectors, their performance in n γ discrimination and fast timing. The aim of this work is to report on the design and assembly of the neutron detectors and their Fig. 1. The neutron wall mounted to the EUROBALL frame (a) and segmentation of the neutron detector array (b) as viewed from the target.

3 O$. Skeppstedt et al./nucl. Instr. and Meth. in Phys. Res. A 421 (1999) into three hermetically separated segments, each viewed by a 130 mm diameter PMT. The subdivision is made in two ways (Fig. 2) in aider to maximize the symmetry of the detector array. The smaller central pentagonal unit is subdivided into five segments, each viewed by a 75 mm diameter PMT. This amounts to a granularity of 50 segments at a distance of 510 mm from the focal point of the neutron detector array Mechanics In Fig. 2 the base plates and an isometric view of both types of hexagons are shown. The effective height of the cells was chosen as 149 mm, yielding about 50% intrinsic efficiency for neutrons evaporated in heavy ion fusion reaction at an acceptable time-of-flight variance [10,16]. Both types of hexagon have a volume of 9.70 l, that is, three sections each of 3.23 l, with an allowance for a variation of 2 4% in the segments due to the irregular shape of the hexagons. The central pentagons have a total volume of 5.37 l consisting of five segments each of 1.07 l. The detector cans have 25 mm high collars around their circumference, allowing the 16 detector units to connect to each other in a selfsupporting way. Scintillation light passes through high-quality glass windows into 130 mm diameter PMTs. The PMTs are enclosed in light tight, black anodised aluminium covers containing magnetic shielding made from 25 μm VITROVAC 6025X metglass tape. The photocathode area of the PMT corresponds in both types of hexagonal detectors to an average of 47% of the exit wall face of the hexagonal segments with a variance of 2% arising from the geometry of the individual segments. The corresponding PMT coverage of the pentagonal segments is 50%. The inner walls of the Al detector cans are painted with three layers of TiO (BC622A) reflector paint which together with the pyramidal shape of the cells ensures good light collection at the photocathode of the PMT. The interface of the neutron wall to the EURO- BALL structure is made via the Ge-Clover section flange (Fig. 1a). The central pentagonal unit will be mounted independently of the other n-detectors on a separate stand. This ensures that the two halves of EUROBALL may be moved perpendicular to the beam line in the normal way. The beam line and its supports, before and behind the EUROBALL frame, support the target chamber which is normally a Si-ball chamber. In experiments in which the 0 pentagonal detector is used, the beam will be stopped inside the target chamber Liquid scintillator For a good n γ discrimination the Bicron BC501A liquid scintillator was chosen. It has been demonstrated in Ref. [5] that this material provides the best performance in this respect. The scintillating cells were filled with BC501A liquid and bubbled throughly with argon gas to remove traces of oxygen. The BC501A scintillator is found to yield optimum pulse-shape discrimination properties when used in conjunction with the XP4512B PMT [5 7,11] Photomultipliers The 130 mm diameter Philips XP4512PA photomultipliers were chosen for use with the hexagonal detectors. They have been used previously in the DEMON neutron detectors [6,7] and have been found to be the best available 130 mm diameter PMTs in a comparative study [6]. The XP4512 PMTs are characterized by a high quantum efficiency and very good photoelectron collection efficiency. A high gain first dynode and a low time jitter of 1 ns ensure a good timing and pulse-shape discrimination in conjunction with liquid scintillators [6]. For the pentagonal detector, Philips XP4312B photomultipliers were used. According to the manufacturers, Philips Photonics, these 75 mm diameter PMTs have similar properties to those of the XP4512B. All the photomultipliers of both types have, according to the manufacturer, a blue photocathode sensitivity of μa/lm F. The high voltage dividers for the PMTs have been designed by Philips Photonics for interaction rates in each singledetector cell of well above 30 khz.

4 534 O$. Skeppstedt et al./nucl. Instr. and Meth. in Phys. Res. A 421 (1999) Fig. 2. Baseplates, sections and isometric views of the two types (a, b and c) of hexagonal detectors.

5 O$. Skeppstedt et al./nucl. Instr. and Meth. in Phys. Res. A 421 (1999) Electronics For the EUROBALL neutron wall integrated electronics consisting of the n γ discriminator, the time-of-flight circuit and an energy output has been built [8]. The present study, however, was carried out with the NIM electronics previously used in the NORDBALL array [9,10] and tested recently as described in Ref. [11] for comparison with previous studies. Fig. 3 shows a block diagram of the experimental arrangement. The anode signal of the tested detector was sent to the n γ discriminator [9] and constant fraction discriminator. The output signals from both units are sent to a time-to-pulse height converter (TPHC) to observe the zero-crossing time distribution. The other TPHC started by another hexagon detector and stopped by the tested detector allows the recording of the time-of-flight spectrum. The anode signal of the tested detector was picked up from the n γ discriminator [9] and sent through a spectroscopy amplifier to provide an energy signal. The output signals were sent to the GSI multiparameter data acquisition system, which was triggered by the coincidence signal of the timeof-flight. To observe the n γ separation due to both PSD and TOF a fission Cm source was placed at the reference detector, about 40 cm away from the tested detector. 3. Performance tests 3.1. Photoelectron yields The number of photoelectrons per energy unit (phe/mev) was measured by the method of Fig. 3. Block diagram of electronics used to test n γ separation by means of zero-crossing pulse-shape discrimination and time-of-flight methods.

6 536 O$. Skeppstedt et al./nucl. Instr. and Meth. in Phys. Res. A 421 (1999) Bertolaccini et al. [12] (see also Refs. [5 7,13]). In this method the number of photoelectrons is measured directly by comparing the position of the Compton-edge of the 662 kev γ-rays from a Cs source to that of a single photoelectron peak, which determines the gain of the PMT. Measurements have been made for all 45 segments of the assembled hexagonal detectors. Fig. 4 shows the distribution of the measured numbers of photoelectrons presented in bins of 100 phe for the 45 detector segments. The photoelectron yields from all segments were found to be between 1000 and 1600 phe/mev with an average of 1300 phe/mev and a variance of σ"150 phe/ MeV. The observed spread of the photoelectron yield cannot be ascribed to the PMTs since the blue photocathode sensitivity is very similar for all the tubes. It has been demonstrated previously that for PMTs of the same type the number of photoelectrons is proportional to the blue photocathode sensitivity [6]. A simple check of the efficiency of light collection with the Cs source placed at the front and back of one of the scintillator cell shows about 15 20% change of the signal amplitude from front to back, reflecting a good light collection. Fig. 4. The distribution of the measured number of photoelectrons/mev for 45 assembled detector segments. Probably the observed spread of the photoelectron number is associated with a non-uniformity of the custom-made scintillator cells, for example, the PMT coupling to the windows. The observed average photoelectron number of 1300 phe/mev can be compared to that measured with the DEMON detectors of 4 l volume [5,7]. For a cylindrical cell of 16 cm diameter and 20 cm height filled with BC501A liquid scintillator viewed by a XP4512B PMT the photoelectron number of 1070 phe/mev was measured for three cells manufactured by Bicron [6 8]. Note that the photocathode area of the 130 mm diameter PMT corresponds to about 66% of the scintillator exit face. In the case of the EUROBALL hexagonal detectors the fraction of the exit face seen by the photocathode is significantly lower (47%). Thus, we conclude that the high light output arises from the pyramidal shape of the EUROBALL detector cells and their somewhat smaller volume Neutron gamma ray discrimination N γ discrimination tests were carried out for a typical detector section with a measured photoelectron number of 1330 phe/mev. The reference detector used in the time-of-flight measurements had a photoelectron yield of 1270 phe/mev. A Cm fission source was used as its neutron energy spectrum resembles closely that of fusionevaporation neutrons. Fig. 5 presents the results of the measurements using the zero-crossing (Z/C) and the time-of-flight (TOF) methods. Fig. 5c shows the main spectrum of the Z/C time distribution versus the TOF. In this spectrum the recorded events are controlled by the threshold of the constant fraction discriminator in the tested detector, which was set at 50 kev of the recoil electrons energy. The log arithmic scale for the Z-axis in Fig. 5 demonstrates the excellent separation of the neutron and γ-ray events for this low energy threshold. At the level corresponding to a fraction of a percent, in relation to the height of γ-ray peak, there is no overlap of neutron and γ-events. Fig. 5a and b represent the Z/C time and TOF spectra versus energy. In this case an ADC threshold corresponding to about 100 kev of recoil electron energy defines the energy threshold.

7 O$. Skeppstedt et al./nucl. Instr. and Meth. in Phys. Res. A 421 (1999) Fig. 5. The n γ discrimination by simultaneous measurement of the zero-crossing time and time-of-flight, measured with a Cm fission source: the Z/C time versus energy (a), the time-of-flight versus energy (b), the Z/C time versus the time-of-flight (c). Note that the analysis of the 2D spectrum of the Z/C versus the time-of-flight allows to select very clearly both the neutron and γ-events. Fig. 5d presents the energy spectrum of neutrons separated by the TOF. Fig. 6 shows the n γ discrimination spectra corresponding to energy gates set at 110, 240, 480 and about 1 MeV of recoil electron energies in the 2D spectrum of Fig. 5a. To quantify the n γ discrimination power at a given energy, a figure of merit, M is used (see Ref. [14]) defined as M"peak separation/(fwhm #FWHM ). (1) γ The M values are given in Fig. 6 for each spectrum and can be compared to those reported in Ref. [7] for the DEMON detectors (see Table 1). Despite the fact that for DEMON detectors the digital

8 538 O$. Skeppstedt et al./nucl. Instr. and Meth. in Phys. Res. A 421 (1999) Table 1 Figure of merit, M, measured for EUROBALL and DEMON detectors Energy (kev) EUROBALL DEMON see Ref. [7], Am Be neutron source. source in Ref. [7]), the quality of n γ discrimination reflected by the M factor is clearly comparable. Note that the gate at 110 kev of recoil electrons corresponds to about 500 kev of neutron energy. Thus, the tested neutron detectors assure very good n γ discrimination down to at least 400 kev of neutron energy, particularly when using the combined PSD and TOF separation methods (see Fig. 5c). The design aim, that the PSD system with the energy threshold set at 400 kev neutron energy implies less than 10% loss of the total efficiency, has been fulfilled with a large margin. Fig. 7 presents the 2D spectrum of Z/C time versus TOF measured with a Co γ-ray source. The two peaks have been obtained in the spectrum by changing a delay in the TOF by 50 ns. It shows a clean region where neutrons should be observed, free of the tails observed in Fig. 5c. High energy γ-rays, in the previous measurements, overload the n γ discriminator and shift the Z/C time (see Fig. 5a). Fig. 8 presents the time spectrum measured for Co γ-rays. The FWHM of the spectrum is equal to 2.20 ns. Since both the hexagonal detectors were adjusted in the same way, with the energy threshold set at 50 kev, the time resolution of one detector is calculated to be 1.56 ns. Fig. 6. The n γ discrimination spectra for gates set at 110, 240, 480 kev and 1 MeV of recoil electron energies from the 2D spectrum of Fig. 5a. The upper spectrum presents the total n γ discrimination spectrum. charge comparison method of pulse-shape discrimination was used and the fact that the two experiments were performed with somewhat different energy gates and neutron sources (Am Be 4. Efficiency of the neutron detectors The efficiency of the EUROBALL neutron detectors is determined by The solid angle Ω subtended by the detectors, which is limited by the forward 1π section of

9 O$. Skeppstedt et al./nucl. Instr. and Meth. in Phys. Res. A 421 (1999) Fig. 7. The 2D spectrum of Z/C time versus TOF measured with γ-rays from a Co source. Fig. 8. Time spectrum measured with two EUROBALL sections of detectors for Co γ-rays. EUROBALL, whose 30 individual Ge detectors contribute only 1.5% to the total 10% efficiency of EUROBALL minimising γ-efficiency losses. The detector thickness, which was chosen as 149 mm, yielding about 50% intrinsic efficiency for evaporation neutrons at an acceptable timeof-flight variance. The low electronic threshold for neutron detection with good n γ discrimination, which is below 400 kev neutron energy.

10 540 O$. Skeppstedt et al./nucl. Instr. and Meth. in Phys. Res. A 421 (1999) Losses due to simultaneous n- and γ-interactions in one detector cell, which are minimized by a high granularity of 50 individual subunits; losses due to wrong Z/C pulse-shape discrimination are assumed to be 410% of the total efficiency for M γ "15. Losses due to suppression of nearest neighbor neutron detector hits to minimize detector cross talk from neutron scattering are estimated to be less than 17% of the total efficiency for a multiplicity M "2 The design aim for the overall intrinsic efficiency is ε 50% for evaporation neutrons, which in their energy distribution compare well to neutrons from a fission source like Cf or Cm used in the present test. Taking into account the kinematical focussing in a symmetric fusion evaporation reaction this should imply a total efficiency ε "30%. The efficiency of the array has been estimated in Monte Carlo simulations and by extrapolation from smaller arrays, namely the NORDBALL [10,15] and OSIRIS systems [16]. The Monte Carlo calculations were found to reproduce the properties of these arrays very well. The efficiency of the detectors for neutrons can be written: ε "P (Ω) Ω/4π ε /(1#ε ) (2) γ where P (Ω) is the kinematic focussing, ε is the intrinsic efficiency and ε is a reduction factor due γ to double n γ hits. For a typical reaction of Ni# Cr at 230 MeV, the kinematic focussing can be estimated as P (Ω) The intrinsic efficiency of +50% results from the 149 mm thick- ness of the detectors assuming a 0.5 MeV threshold of the electronics and a reduction due to double n γ hits estimated to be equal to The probability of n γ double hits was estimated based on earlier experience with the OSIRIS [16] and NORDBALL [10] neutron detector arrays. The results are shown in Table 2. The high granularity of the EUROBALL neutron wall reduces the probability of n γ double hits to the acceptable level of The result of tests of n γ discrimination presented in Section 3.2. shows that losses due to wrong Z/C pulse-shape discrimination and time-of-flight are negligible for the fullenergy range of neutrons. Table 2 The probability of n γ double hits in different neutron detector arrays Array Number of detectors Solid angle OSIRIS [16] 16 2π 0.27 OSIRIS 7 1π 0.36 NORDBALL [10] 15 1π 0.24 EUROBALL 50 1π 0.06 Probability of n γ double hits γ-multiplicity M γ "15, Compton scattering included [16]. In a commissioning experiment the efficiency of a subarray (five hexagons plus pentagon), covering about the same solid angles the final array, was determined in the reaction Ti( Ni, 4pn) Pd at 228 MeV to 27%. This is in excellent agreement with the design data considering the reduced granularity and therefore increased n γ double hit probability. The performance of the neutron detector array is strongly affected by cross talk from scattered neutrons, simulating higher multiplicities leading to misidentification of extremely neutron deficient exit channels and by excessive background from the abundant neutron evaporation channels. Two methods are considered for application in the EUROBALL array, which have been tested earlier with the NORDBALL array [15]. The first one uses the rejection of hits in adjacent detectors leading to a reduction of ε by 17% for 50 detector sections. The other method involves gating on the time difference between neutron hits [15]. The results of a Monte Carlo simulation presented in Fig. 9 show a much narrower time distribution for direct (non scattered) events. Combination of the two methods with the NORDBALL neutron wall led to a reduction of scattered events from a true 1n channel in fold M "2 spectra by a factor of Conclusion The n γ discrimination tests carried out using Z/C pulse-shape discrimination and time-of-flight methods confirm the high quality of the EURO- BALL neutron detectors. A full separation of γ- and neutron-events is observed down to 50 kev of

11 O$. Skeppstedt et al./nucl. Instr. and Meth. in Phys. Res. A 421 (1999) Fig. 9. Monte Carlo simulation of time distributions from direct hits and scattered events in the NORDBALL neutron wall [15]. recoil electron energy. These tests have also demonstrated the excellent timing properties of the detectors. This is reflected in the measured time resolution of 1.56 ns FWHM. The design of the EUROBALL neutron wall, presented in this work combined with the performance of the detectors from our tests, the expected high efficiency of detection and the high rejection of the cross talk caused by scattered neutrons, taken together indicate that the EUROBALL neutron wall will be a very powerful experimental tool for nuclear structure physics. References [1] H. Grawe et al., Progr. Part. Nucl. Phys. 28 (1992) 281. [2] R. Schubart et al., Z. Phys. A 352 (1995) 373. [3] M. Lipoglavs\ ek et al., Phys. Rev. Lett. 76 (1996). [4] H. Grawe et al., Meeting on Inner Balls and Neutron Detectors for EUROBALL, Rossendorf, [5] M. Moszyński et al., Nucl. Instr. and Meth. A 350 (1994) 226. [6] M. Moszyński et al., Nucl. Instr. and Meth. A 307 (1991) 97. [7] M. Moszyński et al., Nucl. Instr. and Meth. A 317 (1992) 262. [8] D. Wolski et al., Meeting on Inner Balls and Neutron Detectors for EUROBALL, Rossendorf, [9] J. Bia"kowski et al., Nucl. Instr. and Meth. A 275 (1989) 525. [10] S.E. Arnell et al., Nucl. Instr. and Meth. A 300 (1991) 303. [11] D. Wolski et al., Nucl. Instr. and Meth. A 360 (1995) 584. [12] M. Bertolaccini et al., Proc. Nucl. Electr. Symp.,Versailles, France, [13] M. Moszyński et al., IEEE Trans. Nucl. Sci. NS-44 (1997) [14] G.F. Knoll, Radiation Detection and Measurements, Wiley, New York, [15] J. Cederkäll et al., Nucl. Instr. and Meth. A 360 (1995) 584. [16] D. Alber et al., Nucl. Instr. and Meth. A 263 (1988) 401. [17] M. Lipoglavs\ ek et al., Z. Phys. A 356 (1996) 239.

Charged particles detectors Arrays (1)

Charged particles detectors Arrays (1) Charged particles detectors Arrays (1) Basic concepts of particle detection: scintillators & semiconductors Light charged particles (p, α, e) Arrays: DIAMANT, ISIS, EUCLIDES, MiniOrange Large Arrays: CHIMERA,

More information

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce F.C.L. Crespi 1,2, F.Camera 1,2, N. Blasi 2, A.Bracco 1,2, S. Brambilla 2, B. Million 2, R. Nicolini 1,2, L.Pellegri 1, S. Riboldi

More information

A Comparison between Channel Selections in Heavy Ion Reactions

A Comparison between Channel Selections in Heavy Ion Reactions Brazilian Journal of Physics, vol. 39, no. 1, March, 2009 55 A Comparison between Channel Selections in Heavy Ion Reactions S. Mohammadi Physics Department, Payame Noor University, Mashad 91735, IRAN (Received

More information

Response function measurements of an NE102A organic scintillator using an 241 Am-Be source

Response function measurements of an NE102A organic scintillator using an 241 Am-Be source Nuclear Instruments and Methods m Physics Research A 345 (1994) 514-519 North-Holland NCLEAR INSTRMENTS & METHODS IN PHYSICS RESEARCH Section A Response function measurements of an NE12A organic scintillator

More information

New Photonis XP20D0 photomultiplier for fast timing in nuclear medicine

New Photonis XP20D0 photomultiplier for fast timing in nuclear medicine New Photonis XP20D0 photomultiplier for fast timing in nuclear medicine M. Moszyński, M. Gierlik, M. Kapusta, A. Nassalski, T. Szczęśniak, Soltan Institute for Nuclear Studies, PL 05-400 Świerk-Otwock,

More information

The neutron wall detector coupled to GALILEO γ-ray array for the study of proton-rich nuclei

The neutron wall detector coupled to GALILEO γ-ray array for the study of proton-rich nuclei Università degli Studi di Padova DIPARTIMENTO DI FISICA ED ASTRONOMIA GALILEO GALILEI Corso di Laurea Triennale in Fisica Tesi di Laurea Triennale The neutron wall detector coupled to GALILEO γ-ray array

More information

New Scintillators for the Border Monitoring Equipment

New Scintillators for the Border Monitoring Equipment New Scintillators for the Border Monitoring Equipment M. Moszynski a a Soltan Institute for Nuclear Studies, PL 05-400 Otwock-Swierk, Poland Performance of new scintillators characterized by a high energy

More information

arxiv: v1 [nucl-ex] 6 May 2008

arxiv: v1 [nucl-ex] 6 May 2008 Digital pulse-shape discrimination of fast neutrons and γ rays P.-A. Söderström a,, J. Nyberg a, R. Wolters a arxiv:0805.0692v1 [nucl-ex] 6 May 2008 a Department of Physics and Astronomy, Uppsala University,

More information

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search Hanwool Joo on behalf of the KIMS-NaI collaboration Department of Physics and Astronomy, 1 Gwanak-ro, Gwanak-gu, Seoul

More information

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A 62 (29) 52 524 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

arxiv:physics/ v1 3 Aug 2006

arxiv:physics/ v1 3 Aug 2006 Gamma Ray Spectroscopy with Scintillation Light in Liquid Xenon arxiv:physics/6834 v1 3 Aug 26 K. Ni, E. Aprile, K.L. Giboni, P. Majewski, M. Yamashita Physics Department and Columbia Astrophysics Laboratory

More information

Non-proportionality of organic scintillators and BGO

Non-proportionality of organic scintillators and BGO Winston-Salem June 4, 2007 Non-proportionality of organic scintillators and BGO A. Nassalski, M. Moszyński, A. Syntfeld-Każuch, Ł. Świderski, T. Szczęśniak. The Soltan Institute for Nuclear Studies, PL

More information

Detection of γ-rays from nuclear decay: 0.1 < E γ < 20 MeV

Detection of γ-rays from nuclear decay: 0.1 < E γ < 20 MeV Detection of -rays from nuclear decay: 0.1 < < 0 MeV Basic concepts of radiation interaction & detection Compound Nucleus reactions and -ray emission High resolution detectors: the semiconductor Ge s Present

More information

arxiv: v1 [physics.ins-det] 16 May 2017

arxiv: v1 [physics.ins-det] 16 May 2017 Measurement of the response of a liquid scintillation detector to monoenergetic electrons and neutrons arxiv:175.5532v1 [physics.ins-det] 16 May 217 P. C. Rout a, A. Gandhi b, T. Basak c, R. G. Thomas

More information

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2 Photons Produced in PbF 2 R. Dolenec a, S. Korpar b,a, P. Križan c,a, R. Pestotnik a, A. Stanovnik d,a a, Ljubljana, Slovenia b Faculty of Chemistry and Chemical Engineering, University of Maribor, Slovenia

More information

Calibration of the Modular Neutron Array (MoNA)

Calibration of the Modular Neutron Array (MoNA) Calibration of the Modular Neutron Array (MoNA) Robert Pepin Gonzaga University ~1~ Calibration of the Modular Neutron Array (MoNA): Figure 1 - A rendering of the Modular Neutron Array In recent years

More information

The Advanced Gamma Ray Tracking Array AGATA

The Advanced Gamma Ray Tracking Array AGATA Nuclear Physics A 746 (2004) 248c 254c The Advanced Gamma Ray Tracking Array AGATA Dino Bazzacco a a INFN, Sezione di Padova, Via Marzolo 8, I 35131 Padova, Italy On behalf of the AGATA collaboration New

More information

MoNA: the Modular Neutron Array

MoNA: the Modular Neutron Array MoNA: the Modular Neutron Array Melanie Evanger National Superconducting Cyclotron Laboratory Michigan State University REU Fellowship e-mail: mrevange@cord.edu August 9, 2002 Abstract The Modular Neutron

More information

Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold Jingke Xu, Princeton (now @LLNL) Sept 24, 2015 2015 LowECal Workshop, Chicago, IL Outline 1. Overview

More information

5 th ASRC International Workshop, 14 th -16 th March 2012

5 th ASRC International Workshop, 14 th -16 th March 2012 Fission Fragment Fragment Spectroscopy with Large Arrays and STEFF A.G. Smith, J. Dare, A. Pollitt, E. Murray The University of Manchester W. Urban, T. Soldner ILL Grenoble I. Tsekhanovich, J. Marrantz

More information

TIGRESS Auxiliary Detectors

TIGRESS Auxiliary Detectors TIGRESS Auxiliary Detectors Gordon Ball, TRIUMF GRETINA Auxiliary Detector Workshop Washington University, St. Louis MO January 28 9, 2006 TIGRESS 32 Fold Segmented HPGe Clover Detector Four ~40% n type

More information

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A 604 (2009) 618 623 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B Journal of the Korean Physical Society, Vol. 32, No. 4, April 1998, pp. 462 467 A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B J. H. Kim, H. Bhang, J. H. Ha, J. C. Kim, M. J. Kim, Y. D. Kim

More information

High-energy Gamma Rays detection with the AMS-02 electromagnetic calorimeter. F. Pilo for the AMS-02 ECAL Group INFN Sezione di Pisa, Italy

High-energy Gamma Rays detection with the AMS-02 electromagnetic calorimeter. F. Pilo for the AMS-02 ECAL Group INFN Sezione di Pisa, Italy Frascati Physics Series Vol. 58 (2014) Frontier Objects in Astrophysics and Particle Physics May 18-24, 2014 High-energy Gamma Rays detection with the AMS-02 electromagnetic calorimeter F. Pilo for the

More information

SCINTILLATION DETECTORS AND PM TUBES

SCINTILLATION DETECTORS AND PM TUBES SCINTILLATION DETECTORS AND PM TUBES General Characteristics Introduction Luminescence Light emission without heat generation Scintillation Luminescence by radiation Scintillation detector Radiation detector

More information

DETECTORS. I. Charged Particle Detectors

DETECTORS. I. Charged Particle Detectors DETECTORS I. Charged Particle Detectors A. Scintillators B. Gas Detectors 1. Ionization Chambers 2. Proportional Counters 3. Avalanche detectors 4. Geiger-Muller counters 5. Spark detectors C. Solid State

More information

Compton suppression spectrometry

Compton suppression spectrometry Compton suppression spectrometry In gamma ray spectrometry performed with High-purity Germanium detectors (HpGe), the detection of low intensity gamma ray lines is complicated by the presence of Compton

More information

Light yield non-proportionality and intrinsic energy resolution of doped CsI scintillators

Light yield non-proportionality and intrinsic energy resolution of doped CsI scintillators NUKLEONIKA 2008;53(2):51 56 ORIGINAL PAPER Light yield non-proportionality and intrinsic energy resolution of doped CsI scintillators Weerapong Chewpraditkul, Lukasz Swiderski, Marek Moszynski Abstract.

More information

Measurements of CsI(Tl) Crystals with PMT and APD. ipno.in2p3.fr Jean Peyré Milano - October 2006

Measurements of CsI(Tl) Crystals with PMT and APD. ipno.in2p3.fr Jean Peyré Milano - October 2006 Measurements of I(Tl) Crystals with PMT and APD Jean Peyré Milano - Oct 2006 IPNO-RDD-Jean Peyré 1 1.Characteristics of I(Tl), PMT and APD 2.Measurements on I(Tl) a) I(Tl) /Teflon + XP5300B b) I(Tl) /VM2000

More information

arxiv: v1 [physics.ins-det] 29 Jun 2011

arxiv: v1 [physics.ins-det] 29 Jun 2011 Investigation of Large LGB Detectors for Antineutrino Detection P. Nelson a,, N. S. Bowden b, a Department of Physics, Naval Postgraduate School, Monterey, CA 99, USA b Lawrence Livermore National Laboratory,

More information

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION OBJECTIVE The primary objective of this experiment is to use an NaI(Tl) detector, photomultiplier tube and multichannel analyzer software system

More information

Design of a Lanthanum Bromide Detector for TOF PET

Design of a Lanthanum Bromide Detector for TOF PET Design of a Lanthanum Bromide Detector for TOF PET A. Kuhn, S. Surti, Member, IEEE, J. S. Karp, Senior Member, IEEE, P. S. Raby, K. S. Shah, A. E. Perkins, Member, IEEE, G. Muehllehner, Fellow Member,

More information

A gas-filled calorimeter for high intensity beam environments

A gas-filled calorimeter for high intensity beam environments Available online at www.sciencedirect.com Physics Procedia 37 (212 ) 364 371 TIPP 211 - Technology and Instrumentation in Particle Physics 211 A gas-filled calorimeter for high intensity beam environments

More information

Isospin symmetry breaking in mirror nuclei. Experimental and theoretical methods

Isospin symmetry breaking in mirror nuclei. Experimental and theoretical methods Isospin symmetry breaking in mirror nuclei Experimental and theoretical methods Silvia M. Lenzi Dipartimento di Fisica dell Università and INFN, Padova, Italy 2. Experimental techniques for mirror spectroscopy

More information

The Versatile Array of Neutron Detectors at Low Energy

The Versatile Array of Neutron Detectors at Low Energy The Versatile Array of Neutron Detectors at Low Energy S. V. Paulauskas, R. Grzywacz, M. Madurga, D. Miller, S. Padgett, W. A. Peters, and the VANDLE Collaboration Why use the time-of-flight technique?

More information

ORTEC AN34 Experiment 10 Compton Scattering

ORTEC AN34 Experiment 10 Compton Scattering EQUIPMENT NEEDED FROM ORTEC 113 Preamplifier (2 ea.) TRUMP-PCI-2K MCA System including suitable PC operating Windows 98/2000/XP (other ORTEC MCAs may be used) 266 Photomultiplier Tube Base (2 ea.) 4001A/4002D

More information

Status & Future for In-Beam Spectrometers for Tagging at JYFL

Status & Future for In-Beam Spectrometers for Tagging at JYFL Status & Future for In-Beam Spectrometers for Tagging at JYFL Department of Physics, Finland Task 1 - Improvement of RDT method (Jyväskylä) Extend the method from α-decay tagging to β-γ tagging, for the

More information

Nuclear Physics and Astrophysics

Nuclear Physics and Astrophysics Nuclear Physics and Astrophysics PHY-30 Dr. E. Rizvi Lecture 4 - Detectors Binding Energy Nuclear mass MN less than sum of nucleon masses Shows nucleus is a bound (lower energy) state for this configuration

More information

Improving neutron detection efficiency by using passive converters

Improving neutron detection efficiency by using passive converters Nuclear Instruments and Methods in Physics Research B 192 (2002) 339 344 www.elsevier.com/locate/nimb Improving neutron detection efficiency by using passive converters T. Baumann a, *, H. Ikeda b,c, M.

More information

Hands on Project: Large Photocathode PMT Characterization

Hands on Project: Large Photocathode PMT Characterization Hands on Project: Large Photocathode PMT Characterization Rickard Stroem Dept. of Physics and Astronomy, Uppsala University E-mail: rickard.strom@physics.uu.se Institute of Cosmic Ray Research, University

More information

Large Area Avalanche Photodiodes in X-rays and scintillation detection

Large Area Avalanche Photodiodes in X-rays and scintillation detection Nuclear Instruments and Methods in Physics Research A 442 (2000) 230}237 Large Area Avalanche Photodiodes in X-rays and scintillation detection M. MoszynH ski *, M. Kapusta, M. Balcerzyk, M. Szawlowski,

More information

First results from the AGATA Demonstrator. Francesco Recchia Università di Padova

First results from the AGATA Demonstrator. Francesco Recchia Università di Padova First results from the AGATA Demonstrator Francesco Recchia Università di Padova XCVII Congresso Nazionale SIF L'Aquila, 26-30 Settembre, 2011 Challenges in Nuclear Structure Shell structure in nuclei

More information

Characterisation of the first prototype of the neutron detector array NEDA

Characterisation of the first prototype of the neutron detector array NEDA Università degli Studi di Padova Dipartimento di Fisica ed Astronomia Corso di Laurea in Fisica Tesi di Laurea Triennale Characterisation of the first prototype of the neutron detector array NEDA Relatori:

More information

arxiv: v1 [physics.ins-det] 3 Feb 2011

arxiv: v1 [physics.ins-det] 3 Feb 2011 Nuclear Instruments and Methods in Physics Research A 00 (2018) 1 5 Alogo.pdf Nuclear Instruments and Methods in Physics Research A Scintillation decay time and pulse shape discrimination in oxygenated

More information

Update on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS)

Update on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS) Update on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS) K. Garrow 1, B.J. Lewis 2, L.G.I. Bennett 2, M.B. Smith, 1 H. Ing, 1 R. Nolte, 3 S. Röttger, R 3 R. Smit 4

More information

1 Introduction. KOPIO charged-particle vetos. K - RARE Meeting (Frascati) May Purpose of CPV: veto Kl

1 Introduction. KOPIO charged-particle vetos. K - RARE Meeting (Frascati) May Purpose of CPV: veto Kl Introduction - Purpose of CPV: veto Kl decay modes with a real or apparent π and a pair of charged particles - Examples of background modes: (i) K l π π + π (ii) K l π π ± eν there are always (iii) K l

More information

STUDY ON THE ENERGY RESPONSE OF PLASTIC SCINTILLATION DETECTOR TO MEV NEUTRONS ABSTRACT

STUDY ON THE ENERGY RESPONSE OF PLASTIC SCINTILLATION DETECTOR TO MEV NEUTRONS ABSTRACT STUDY ON THE ENERGY RESPONSE OF PLASTIC SCINTILLATION DETECTOR TO 0.75-14.75 MEV NEUTRONS Jianfu Zhang 1, 2, Xiaoping Ouyang 1, 2, Suizheng Qiu 1, Xichao Ruan 3, Jinlu Ruan 2 1 School of Nuclear Science

More information

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals Wolfgang Hennig, Hui Tan, William K Warburton, and Justin I McIntyre

More information

XMASS: a large single-phase liquid-xenon detector

XMASS: a large single-phase liquid-xenon detector XMASS: a large single-phase liquid-xenon detector Katsuki Hiraide, the university of Tokyo for the XMASS Collaboration October 3 rd, 2016 IPRD16@Siena, Italy 1 XMASS project XMASS: a multi purpose experiment

More information

Measurements of liquid xenon s response to low-energy particle interactions

Measurements of liquid xenon s response to low-energy particle interactions Measurements of liquid xenon s response to low-energy particle interactions Payam Pakarha Supervised by: Prof. L. Baudis May 5, 2013 1 / 37 Outline introduction Direct Dark Matter searches XENON experiment

More information

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous? Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous? 2. Briefly discuss dead time in a detector. What factors are important

More information

José Antonio Briz Monago, M. Carmona-Gallardo and. M.J.G. Borge, A. Perea, O. Tengblad, M. Turrión

José Antonio Briz Monago, M. Carmona-Gallardo and. M.J.G. Borge, A. Perea, O. Tengblad, M. Turrión GEANT4 SIMULATIONS FOR THE R3B CALORIMETER José Antonio Briz Monago, M. Carmona-Gallardo and M.J.G. Borge, A. Perea, O. Tengblad, M. Turrión Outline Introduction: FAIR at GSI (Germany) R3B Experiment Requirements

More information

Compton Camera. Compton Camera

Compton Camera. Compton Camera Diagnostic Imaging II Student Project Compton Camera Ting-Tung Chang Introduction The Compton camera operates by exploiting the Compton Effect. It uses the kinematics of Compton scattering to contract

More information

Energy Resolution of Scintillation Detectors New Observations

Energy Resolution of Scintillation Detectors New Observations Energy Resolution of Scintillation Detectors New Observations M. Moszyński, A. Nassalski, Ł. Świderski, A. Syntfeld-Każuch, T. Szczęśniak, Soltan Institute for Nuclear Studies PL 05-400 Otwock-Świerk,

More information

The heavy-ion magnetic spectrometer PRISMA

The heavy-ion magnetic spectrometer PRISMA Nuclear Physics A 701 (2002) 217c 221c www.elsevier.com/locate/npe The heavy-ion magnetic spectrometer PRISMA A.M. Stefanini a,,l.corradi a,g.maron a,a.pisent a,m.trotta a, A.M. Vinodkumar a, S. Beghini

More information

New data on β decay of exotic nuclei close to 100 Sn:

New data on β decay of exotic nuclei close to 100 Sn: New data on β decay of exotic nuclei close to 1 Sn: 94 Ag and 1 In C. Plettner 1, I. Mukha 1, J. Döring 1, L. Batist 2, H. Grawe 1, A. Blazhev 1,3, C. R. Hoffman 4, Z. Janas 5, R. Kirchner 1, M. La Commara

More information

arxiv: v2 [nucl-ex] 10 Jun 2009

arxiv: v2 [nucl-ex] 10 Jun 2009 Discrimination of gamma rays due to inelastic neutron scattering in AGATA A. Ataç,a, A. Kaşkaş a, S. Akkoyun a,, M. Şenyiğit a, T. Hüyük a, S. O. Kara a, J. Nyberg b a Department of Physics, Faculty of

More information

Scintillation Detectors

Scintillation Detectors Scintillation Detectors Introduction Components Scintillator Light Guides Photomultiplier Tubes Formalism/Electronics Timing Resolution Elton Smith JLab 2006 Detector/Computer Summer Lecture Series Experiment

More information

arxiv: v1 [nucl-ex] 4 Sep 2008

arxiv: v1 [nucl-ex] 4 Sep 2008 A large area plastic scintillator detector array for fast neutron measurements arxiv:0809.0794v1 [nucl-ex] 4 Sep 2008 P. C. Rout a,b, D. R. Chakrabarty a,b, V. M. Datar a,b, Suresh Kumar a, E. T. Mirgule

More information

Mass of the electron m 0

Mass of the electron m 0 Mass of the electron m 0 1 Objective To determine the rest mass of the electron, m e, via γ-ray interactions (mainly Compton scattering and photoeffect) in a NaI scintillation detector. Based on the enclosed

More information

Light ion recoil detector

Light ion recoil detector Light ion recoil detector Overall design The detector for light (target-like) particles is a substantial part of the R3B setup. It allows registration of recoils in coincidence with the heavy fragments,

More information

EEE4106Z Radiation Interactions & Detection

EEE4106Z Radiation Interactions & Detection EEE4106Z Radiation Interactions & Detection 2. Radiation Detection Dr. Steve Peterson 5.14 RW James Department of Physics University of Cape Town steve.peterson@uct.ac.za May 06, 2015 EEE4106Z :: Radiation

More information

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo ICEPP, the University of Tokyo E-mail: sawada@icepp.s.u-tokyo.ac.jp The MEG experiment yielded the most stringent upper limit on the branching ratio of the flavorviolating muon decay µ + e + γ. A major

More information

arxiv:astro-ph/ v1 15 Feb 2005

arxiv:astro-ph/ v1 15 Feb 2005 The XENON Dark Matter Experiment Elena Aprile (on behalf of the XENON collaboration) Physics Department and Columbia Astrophysics Laboratory, Columbia University, New York, New York 10027 age@astro.columbia.edu

More information

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS ANTOANETA ENE 1, I. V. POPESCU 2, T. BÃDICÃ 3, C. BEªLIU 4 1 Department of Physics, Faculty

More information

M.J. CIESLAK, K.A.A. GAMAGE Department of Engineering, Lancaster University Lancaster, LA1 4YW United Kingdom ABSTRACT

M.J. CIESLAK, K.A.A. GAMAGE Department of Engineering, Lancaster University Lancaster, LA1 4YW United Kingdom ABSTRACT PULSE SHAPE DISCRIMINATION CHARACTERISTICS OF STILBENE CRYSTAL, EJ-299-33 AND 6 Li LOADED PLASTIC SCINTILLATORS FOR A HIGH RESOLUTION CODED-APERTURE NEUTRON IMAGER M.J. CIESLAK, K.A.A. GAMAGE Department

More information

Advances in the Micro-Hole & Strip Plate gaseous detector

Advances in the Micro-Hole & Strip Plate gaseous detector Nuclear Instruments and Methods in Physics Research A 504 (2003) 364 368 Advances in the Micro-Hole & Strip Plate gaseous detector J.M. Maia a,b,c, *, J.F.C.A. Veloso a, J.M.F. dos Santos a, A. Breskin

More information

Development of new instrumentation for epithermal neutron scattering at very low angles

Development of new instrumentation for epithermal neutron scattering at very low angles Nuclear Instruments and Methods in Physics Research A 535 (2004) 121 125 www.elsevier.com/locate/nima Development of new instrumentation for epithermal neutron scattering at very low angles M. Tardocchi

More information

PoS(NIC XI)248. Cross section measurements of 103 Rh(p, γ) 104 Pd with the Karlsruhe 4πBaF 2 detector

PoS(NIC XI)248. Cross section measurements of 103 Rh(p, γ) 104 Pd with the Karlsruhe 4πBaF 2 detector Cross section measurements of 103 Rh(p, γ) 104 Pd with the Karlsruhe 4πBaF 2 detector a,b, S. Walter c, F. Käppeler c, R. Plag a,b, R. Reifarth a,b, E-mail: m.weigand@gsi.de a GSI Helmholtzzentrum für

More information

Development of a neutron time-of-flight source at the ELBE accelerator

Development of a neutron time-of-flight source at the ELBE accelerator Development of a neutron time-of-flight source at the ELBE accelerator *,1, E. Altstadt 2, C. Beckert 2, R. Beyer 1, H. Freiesleben 3, V. Galindo 2, M. Greschner 3, E. Grosse 1,3, A. R. Junghans 1, D.

More information

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator 88 The 1 st NPRU Academic Conference SCI-O11 Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator P. Limkitjaroenporn and W.Chewpraditkul Radiation Physics Laboratory,

More information

Detectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors

Detectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors 1 Detectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors C. Fiorini, A. Longoni, F. Perotti, C. Labanti, E. Rossi, P. Lechner,

More information

arxiv: v1 [physics.ins-det] 27 Sep 2018

arxiv: v1 [physics.ins-det] 27 Sep 2018 Quenching factor measurement for a NaI(Tl) scintillation crystal arxiv:1809.10310v1 [physics.ins-det] 27 Sep 2018 H.W. Joo 1,2, H.S. Park 1,, J.H. Kim 1, S.K. Kim 2,, Y.D. Kim 3 H.S. Lee, 3, S.H. Kim 3

More information

RESPONSE FUNCTION STUDY FOR ENERGY TO LIGHT CONVERSION IN ORGANIC LIQUID SCINTILLATORS

RESPONSE FUNCTION STUDY FOR ENERGY TO LIGHT CONVERSION IN ORGANIC LIQUID SCINTILLATORS RESPONSE FUNCTION STUDY FOR ENERGY TO LIGHT CONVERSION IN ORGANIC LIQUID SCINTILLATORS S. Prasad *, A. Enqvist, S. D. Clarke, S. A. Pozzi, E. W. Larsen 1 Department of Nuclear Engineering and Radiological

More information

Chinese Physics C. Study of n-γ discrimination in low energy range (above 40. kevee) by charge comparison method with a BC501A liquid

Chinese Physics C. Study of n-γ discrimination in low energy range (above 40. kevee) by charge comparison method with a BC501A liquid CPC(HEP & NP) Chinese Physics C Study of n-γ discrimination in low energy range (above 40 kevee) by charge comparison method with a BC501A liquid scintillation detector CHEN Yong-Hao( 陈永浩 ) 1, CHEN Xi-Meng(

More information

Tests of the Burle anode MCP PMT as a detector of Cherenkov photons

Tests of the Burle anode MCP PMT as a detector of Cherenkov photons uclear Instruments and Methods in Physics Research A 567 (26) 124 128 www.elsevier.com/locate/nima Tests of the Burle 8511 64-anode MCP PMT as a detector of Cherenkov photons P. Krizˇan a,b,, I. Adachi

More information

Studies of Hadron Calorimeter

Studies of Hadron Calorimeter Studies of Hadron Calorimeter Zhigang Wang Institute of High Energy Physics 2012.10.17 in IHEP Outline 1,The Dark Matter Calorimeter 2,The Hadron Calorimeter(HCAL) 3, Summary 1,Dark Matter Calorimeter

More information

DEVELOPING OF A VME COMPLEX NEUTRON MEASUREMENT SYSTEM AT IFIN-HH TANDEM ACCELERATOR USING A NEUTRON ARRAY DETECTOR *

DEVELOPING OF A VME COMPLEX NEUTRON MEASUREMENT SYSTEM AT IFIN-HH TANDEM ACCELERATOR USING A NEUTRON ARRAY DETECTOR * DEVELOPING OF A VME COMPLEX NEUTRON MEASUREMENT SYSTEM AT IFIN-HH TANDEM ACCELERATOR USING A NEUTRON ARRAY DETECTOR * HORIA PETRASCU 1, IULIA COMPANIS 1, ALINA ISBASESCU 1, MICHAEL FAMIANO 2 1 Horia Hulubei

More information

arxiv: v2 [physics.ins-det] 28 Jul 2010

arxiv: v2 [physics.ins-det] 28 Jul 2010 Pulse-Shape Discrimination of CaF 2 (Eu) S. Oguri a,1, Y. Inoue b, M. Minowa a arxiv:1007.4750v2 [physics.ins-det] 28 Jul 2010 a Department of Physics, School of Science, University of Tokyo, 7-3-1, Hongo,

More information

Radiation Detection and Measurement

Radiation Detection and Measurement Radiation Detection and Measurement Third Edition Glenn F. Knoll Professor of Nuclear Engineering and Radiological Sciences University of Michigan Ann Arbor, Michigan John Wiley & Sons, Inc. New York/Chichester/Weinheim/Brisbane/Toronto/Singapore

More information

Scintillation Detectors

Scintillation Detectors Scintillation Detectors Introduction Components Scintillator Light Guides Photomultiplier Tubes Formalism/Electronics Timing Resolution Elton Smith JLab 2009 Detecto Summer Lecture Series Experiment basics

More information

High-Resolution Gamma-Ray and Neutron Detectors For Nuclear Spectroscopy

High-Resolution Gamma-Ray and Neutron Detectors For Nuclear Spectroscopy High-Resolution Gamma-Ray and Neutron Detectors For Nuclear Spectroscopy Thomas Niedermayr, I. D. Hau, S. Terracol, T. Miyazaki, S. E. Labov and S. Friedrich Former colleagues: M. F. Cunningham, J. N.

More information

Louis Baum University of Michigan, REU Student Summer UM Nuclear Sciences Group

Louis Baum University of Michigan, REU Student Summer UM Nuclear Sciences Group Louis Baum University of Michigan, REU Student Summer 2011 UM Nuclear Sciences Group Overview Background Why Detectors Time of Flight Road Blocks Conclusion Main Side Project Californium 252 Fission Source

More information

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory Recent Activities on Neutron Standardization at the Electrotechnical Laboratory K. Kudo, N. Takeda, S. Koshikawa and A. Uritani Quantum Radiation Division, National Metrology Institute of Japan (NMIJ)

More information

Investigation of pulse shapes and time constants for NaI scintillation pulses produced by low energy electrons from beta decay

Investigation of pulse shapes and time constants for NaI scintillation pulses produced by low energy electrons from beta decay 11 November 1999 Ž. Physics Letters B 467 1999 132 136 Investigation of pulse shapes and time constants for NaI scintillation pulses produced by low energy electrons from beta decay N.J.T. Smith a, P.F.

More information

Observation of High Multiplicity Bursts of Neutrons During Electrolysis of Heavy Water with Palladium Cathode Using the Dead-Time Filtering Technique

Observation of High Multiplicity Bursts of Neutrons During Electrolysis of Heavy Water with Palladium Cathode Using the Dead-Time Filtering Technique Shyam, A., et al. Observation of High Multiplicity Bursts of Neutrons During Electrolysis of Heavy Water with Palladium Cathode Using the Dead-Time Filtering Technique. in 5th International Conference

More information

Kaon Identification at NA62. Institute of Physics Particle, Astroparticle, and Nuclear Physics groups Conference 2015

Kaon Identification at NA62. Institute of Physics Particle, Astroparticle, and Nuclear Physics groups Conference 2015 Kaon Identification at NA62 Institute of Physics Particle, Astroparticle, and Nuclear Physics groups Conference 2015 Francis Newson April 2015 Kaon Identification at NA62 K πνν NA48 and NA62 K + π + νν

More information

a monte carlo simulation of photomultiplier resolution

a monte carlo simulation of photomultiplier resolution technical reprint R/P080 a monte carlo simulation of photomultiplier resolution a Monte Carlo simulation of photomultiplier resolution A G Wright, Electron Tubes Limited, Bury Street, Ruislip, Middlesex

More information

GEM-based photon detector for RICH applications

GEM-based photon detector for RICH applications Nuclear Instruments and Methods in Physics Research A 535 (2004) 324 329 www.elsevier.com/locate/nima GEM-based photon detector for RICH applications Thomas Meinschad, Leszek Ropelewski, Fabio Sauli CERN,

More information

Digital Gamma-ray Spectroscopy & Imaging with Semiconductor detectors Frontiers of gamma-ray spectroscopy

Digital Gamma-ray Spectroscopy & Imaging with Semiconductor detectors Frontiers of gamma-ray spectroscopy Digital Gamma-ray Spectroscopy & Imaging with Semiconductor detectors Frontiers of gamma-ray spectroscopy AGATA GRETA Dr Andy Boston ajboston@liv.ac.uk And its applications The AGATA Concept Without Compton

More information

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan Nagoya university, Nagoya, Japan E-mail: kenji@hepl.phys.nagoya-u.ac.jp We have studied timing properties of 4 different types of micro-channel-plate photo-multiplier tubes (MCP-PMT) by irradiating with

More information

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A ] (]]]]) ]]] ]]] Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

Energy resolution and absolute detection efficiency for LSO crystals: a comparison between Monte Carlo simulation and experimental data

Energy resolution and absolute detection efficiency for LSO crystals: a comparison between Monte Carlo simulation and experimental data Energy resolution and absolute detection efficiency for LSO crystals: a comparison between Monte Carlo simulation and experimental data Harold Rothfuss a,b, Larry Byars c, Michael E. Casey a, Maurizio

More information

A progress report on the development of the CsI-RICH detector for the ALICE experiment at LHC

A progress report on the development of the CsI-RICH detector for the ALICE experiment at LHC Nuclear Instruments and Methods in Physics Research A 409 (1998) 385 389 A progress report on the development of the CsI-RICH detector for the ALICE experiment at LHC H. Beker, A. Braem, N. Colonna, M.

More information

Radiation Detection and Measurement

Radiation Detection and Measurement Radiation Detection and Measurement Fourth Edition Glenn F. Knoll Professor Emeritus of Nuclear Engineering and Radiological Sciences University of Michigan Ann Arbor, Michigan WILEY John Wiley & Sons,

More information

A method to measure transit time spread of photomultiplier tubes with Cherenkov light

A method to measure transit time spread of photomultiplier tubes with Cherenkov light Nuclear Science and Techniques 20 (2009) 344 348 A method to measure transit time spread of photomultiplier tubes with Cherenkov light WU Chong 1 DONG Huasong 2,* SUN Zhijia 3 1 Department of Mathematics

More information

Direct WIMP Detection in Double-Phase Xenon TPCs

Direct WIMP Detection in Double-Phase Xenon TPCs Outline PMTs in the XENON dark matter experiment XENON100 and the weekly gain calibration XENON1T and candidates for the light sensors Tests of Hamamatsu R11410 2 Direct WIMP Detection in Double-Phase

More information

Dedicated Arrays: MEDEA GDR studies (E γ = MeV) Highly excited CN E*~ MeV, 4 T 8 MeV

Dedicated Arrays: MEDEA GDR studies (E γ = MeV) Highly excited CN E*~ MeV, 4 T 8 MeV Dedicated Arrays: MEDEA GDR studies (E γ = 10-25 MeV) Highly excited CN E*~ 250-350 MeV, 4 T 8 MeV γ-ray spectrum intermediate energy region 10 MeV/A E beam 100 MeV/A - large variety of emitted particles

More information

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

Nuclear Lifetimes. = (Eq. 1) (Eq. 2) Nuclear Lifetimes Theory The measurement of the lifetimes of excited nuclear states constitutes an important experimental technique in nuclear physics. The lifetime of a nuclear state is related to its

More information

Neutron Shell : a high efficiency array of neutron detectors for g-ray spectroscopic studies with Gammasphere

Neutron Shell : a high efficiency array of neutron detectors for g-ray spectroscopic studies with Gammasphere Nuclear Instruments and Methods in Physics Research A 530 (2004) 473 492 Neutron Shell : a high efficiency array of neutron detectors for g-ray spectroscopic studies with Gammasphere D.G. Sarantites a,

More information