1 Aerosol Science and Technology ISSN: (Print) (Online) Journal homepage: Reducing Particle Bounce and Loading Effect for a Multi-Hole Impactor Chane-Yu Lai, Sheng-Hsiu Huang, Cheng-Ping Chang & Jia-Yun Lin To cite this article: Chane-Yu Lai, Sheng-Hsiu Huang, Cheng-Ping Chang & Jia-Yun Lin (2008) Reducing Particle Bounce and Loading Effect for a Multi-Hole Impactor, Aerosol Science and Technology, 42:2, , DOI: / To link to this article: Published online: 24 Oct Submit your article to this journal Article views: 525 View related articles Citing articles: 7 View citing articles Full Terms & Conditions of access and use can be found at Download by: [ ] Date: 20 December 2017, At: 17:45
2 Aerosol Science and Technology, 42: , 2008 Copyright c American Association for Aerosol Research ISSN: print / online DOI: / Reducing Particle Bounce and Loading Effect for a Multi-Hole Impactor Chane-Yu Lai, 1 Sheng-Hsiu Huang, 2 Cheng-Ping Chang, 2 and Jia-Yun Lin 3 1 Department of Occupational Safety & Health, College of Health Care & Management, Chung Shan Medical University, Taichung, Taiwan 2 Institute of Occupational Safety and Health, Council of Labour Affairs, Executive Yuan, Sijhih City, Taipei County, Taiwan 3 Department of Public Health, College of Health Care & Management, Chung Shan Medical University, Taichung, Taiwan Aerosol sampling is used to evaluate the health hazards associated with particles deposited in the human breathing system. Impactors, which are extensively employed as aerosol samplers, have low collection efficiency because of particle bounce. The impaction plate is typically coated with oil or grease to prevent particle bounce. However, such coating materials cannot sustain long-term heavy particle loading. In this study, the impaction plate was recessed, forming a cavity filled with Trypticase Soy Agar (TSA) to reduce particle bounce and re-entrainment. An ultrasonic atomizing nozzle was employed to generate challenge aerosols. An Aerodynamic Particle Sizer (APS) was utilized to measure the number concentrations and the size distributions upstream and downstream of the size-selective devices. A multi-hole impactor and Personal Environmental Monitor PM 2.5 (PEM PM 2.5 ) were used to evaluate particle bounce and heavy particle loading. Liquid type-dioctyl phthalate (DOP), soluble solid type-potassium sodium tartrate tetrahydrate (PST) and insoluble solid type-polymethyl methacrylate (PMMA) were investigated, as were different impaction surfaces/surface combinations. The multi-hole impactor coated with silicone oil was compared with a TSA-filled plate. Laboratory results demonstrate that the solid PST particles bounced off the TSA-filled plate less than off the silicone-coated aluminum plate. This study also used a 700-µmthick layer of silicone oil to prevent TSA dehydration. The experimental results revealed that the silicone-tsa double layer minimized PST particle bounce during the two-hour heavy sampling (mass concentration was around 7.22 mg/m 3 ). Moreover, the PEM- PM 2.5 impactor yielded consistent results when the silicone-tsa Received 7 August 2006; accepted 14 November The authors would like to thank the National Science Council of the Republic of China, Taiwan, for financially supporting this research under Contract Nos. NSC E and NSC C E. Chung Shan Medical University is appreciated for supporting the patent application. Address correspondence to Chane-Yu Lai, Department of Occupational Safety & Health, College of Health Care & Management, Chung Shan Medical University, No. 110, Section 1, Chien-Kuo North Rd., Room 511, Taichung 402, Taiwan. cylai@csmu.edu.tw 114 double layer method was used. These results are useful for designing bounce-free impaction substrates during heavy load sampling. INTRODUCTION Impactors have been commonly used to measure the mass concentration and size distribution of ambient particles. Impactors can also be utilized in respirable sampling when appropriately designed. To determine accurate particle size distributions, particles impacting on the collection substrate must stick to it without bouncing off resulting in subsequent collection on a downstream stage (Dzubay et al. 1976; Esmen 1980; Markowski 1984; Lai et al. 2002). Particle bounce-off depends on many factors such as the impaction surface characteristics, coating type and depth, particle types, particle loading on the impaction surface, sampling conditions and impaction substrate design (Rao and Whitby 1978a, b; Reischl and John 1978; Turner and Hering 1987; Newton et al. 1990; Pak et al. 1992; Tsai and Cheng 1995; Chang et al. 1999; Hinds 1999). Therefore, in order to obtain unbiased particle size and mass concentration distributions, particle bounce-off and re-entrainment from the impaction surface must be minimized. This is particularly important for long-term sampling in heavy particle loading conditions that often results in excessive layers of deposited particles. Novel impactor designs, such as the MOUDI, however, may alleviate the problems of excessive particle loading by using rotating impaction stages as described by Marple et al. (1991). Studies have shown that impaction plates coated with adhesive materials like grease or oil can effectively eliminate particle bounce-off problems. However, greased surfaces are often quickly overloaded with particles. Under such conditions incoming particles impact on collected particles rather than the greased surface resulting in particle bounce-off. This effect is particularly likely to occur during long-term sampling under heavy particle loading concentrations (Reischl and John 1978;
3 REDUCING PARTICLE BOUNCE AND LOADING EFFECT 115 Turner and Hering 1987). In some studies low viscosity oils have shown a better performance than grease under certain conditions. This was attributed to the fact that the oils could wick up to the top of particle layer by capillary action and thereby incoming particles would be more likely to be impacting on the coated surface (Pak et al. 1992). Low viscosity oil, however, may not be convenient for personal sampling especially when the subject is moving and the sampler may tilt or shake. For example, Robert et al. (2001) studied the sensitivity of the USEPA WINS PM 2.5 Separator to different impaction surface substrate preparations in its well-shaped collection region. The WINS impaction surface substrate consists of a glass fiber filter (37 mm in diameter) saturated with 1 ml of silicone oil. The size-selective performance of WINS was independent of the volume of oil used in the range from ml. Compared to a conventional flat plate impactor, the WINS impactor was found to be very effective in capturing all large particles in the well-shaped collection region. Unlike conventional flat plate impactors, loading of the WINS substrate shifts the performance curve to smaller cutpoints and large particles are collected before the afterfilter. A metallic well without oil, however, produced a broad separation curve with a 50% cut-off diameter larger than the design value of 2.5 µm. Lai and Chen (2000) also compared aerosol separation efficiency of inlet heads of a Harvard impactor, Personal Environmental Monitor (PEM) and Anderson dichotomous sampler (model 241). Their study showed that particle bounce-off effect was minimized by a silicone oil coating on the impaction plate. However, impaction cavities and wells can improve impactor performance compared to flat surfaces. Several studies have examined varying configuration and sampling conditions for impactors with collection cavities such as quiescence, no surface coating and additional substrates (Scott and Ranz 1976; Biswas and Flagan 1988; Tsai and Cheng 1995; Chang et al. 1999). Their experimental results indicate that greased substrates eliminate particle bounce. These studies were conducted exclusively to minimize particle bounce and re-entrainment, and, the effect of long-term heavy particle loading was not investigated. The study presented here examines the possibility of achieving high particle collection efficiency for long-term sampling with heavy particle loading through the investigation of various coating techniques. Trypticase Soy Agar (TSA), a commonly used culture medium, was prepared and used to fill the open cavity of an impactor body to minimize solid particle bounce and loading. Laboratory tests identified an optimum configuration, minimizing particle bounce and sustaining heavy particle loading. EXPERIMENTAL Two samplers were employed in this experiment the PEM- PM 2.5 (model 200, MSP Co., Minneapolis, MN, USA) and a modified multi-hole impactor. The PEM-PM 2.5 sampler is a one-stage impactor with a porous metal impaction plate. The sampling flow rate of the PEM-PM 2.5 impactor was 10 L/min, with a 50% cut-off size of 2.5 µm. The multi-hole impactor was modified and used as a size-selective respirable sampler for sampling particles (Figure 1) (Lai et al. 2002). The impactor is comprised of the following three components: (1) a nozzle plate with six inlet holes (diameters of 1.9 mm) as the sampling nozzles; (2) a ring-type impaction medium (thickness of 3.5 mm), including a conventional flat aluminum plate and TSA colloid (Difco, Detroit, MI, USA); and (3) a body with a ring-type open cavity (depth of 3.5 mm). The sampling flow FIG. 1. Schematic diagram of a multi-hole impactor.
4 116 C.-Y. LAI ET AL. FIG. 2. Schematic diagram of the experimental set-up (PMMA generation was not simultaneous with PST/DOP generation). rate of the test multi-hole impactor was set at 3.6 L/min with a calculated 50% cut-off size of approximately 4 µm. Typically, for a round jet impactor, cut-size (d p50 ) can be predicted (Marple and Willeke 1976; Hinds 1999) based on the impactor s critical dimensions and the properties of the air stream: 9µW 9πnµW Cc d p50 = Stk50 = 3 Stk50 [1] ρ p U 4ρ p Q where C c is the unitless particle slip correction factor, µ is the dynamic viscosity of the airstream (g/cm-s), W is the impactor jet width (cm), ρ p is the particle density (g/cm 3 ), U is the mean fluid velocity through the jet (cm/s), S tk50 is the dimensionless impaction parameter, n is the number of jets, and Q is the volumetric flow rate through the impactor (cm 3 /s). Once the cutpoint is known, changes in the stage performance versus various operating parameters can be predicted using Equation (1) (Robert et al. 2001). Aerosols were drawn into the multi-hole impactor through six inlet nozzles positioned radially at 60 degrees. The particle accelerates through the nozzle and impacts on the collection medium. Two impaction plates were designed a conventional flat-ring aluminum plate and an elastic TSA-filled plate. When the aluminum plate was assembled with a body part with an open cavity, the multi-hole impactor was designed as a conventional one-stage impactor. However, the soft TSA-filling can be an impaction plate. TSA is a commonly used, soft, semi-solid culture medium designed to support the growth of various bacterial species. In this study, different mass concentrations of TSA were dissolved in hot water; solutions of 1, 3, and 6% TSA were prepared and poured into the open cavity of the impactor body to minimize solid particle bouncing and loading. Unlike a fluid silicone oil filled into an impinger and a conventional hard-flat impaction plate, TSA provides a soft impaction surface. However, to avoid the dehydration of TSA, the TSA-filling cavity was coated with a thin layer of silicone oil (thickness, approximately 700 µm) to prevent evaporation resulting from air flow. The aerosol flow after impaction was directed into a conical expander (body part) designed to yield a uniform aerosol deposition on the downstream filter for future use. The sampling time for all the sampling procedures was 60 sec. Five replicates of sampling were utilized to measure separation curves. The sampling system, displayed in Figure 2, was grounded during testing to avoid any interference by electrostatic attraction. Average flow velocity in the test section was 0.1 m/s, measured using an anemometer (model V-01-AN I. Denshi CO., Ltd., Tokyo, Japan.). Hence, the flow field in the test section was under generally calm air conditions. While these two samplers had different sampling flow rates (the multi-hole impactor was 3.6 L/min; the PEM-PM 2.5 was 10 L/min), the downstream sampling train between the aerodynamic particle sizer (APS, model 3321, TSI, Inc., Minneapolis, MN, USA) and samplers had an alternate suction apparatus to draw or supply auxiliary air for the samplers. The reference sampling probe was incorporated into the APS attachment and was used to measure upstream challenge aerosols. Aerosol size distribution, number concentrations and wall losses at the sampler, and an upstream measurement location were checked; no statistically significant differences were found. Except for large particle sizes, the size-dependent aspiration efficiency of the reference sampling probe at 3.6 l/min and 10 l/min was similar. All the test results were adjusted for aspiration efficiency. However, the determination of the aspiration efficiency of the reference sampling probe in calm air is a complex procedure not performed in this work.
5 An ultrasonic atomizing nozzle (model , Sonotek Inc., Highland, NY, USA) was employed to generate solution droplets with a count median diameter (CMD) of µm and a geometric standard deviation (GSD, σ g )ofaround 2. The solution was forced through silicone tubing using a syringe pump. After the solvent had evaporated, the volumetric concentration of the solution being atomized was set to provide a preferred CMD. Furthermore, a calculation based on Hatch- Choate equations provides an estimate of mass mean diameter (MMD) (Hinds 1999): REDUCING PARTICLE BOUNCE AND LOADING EFFECT 117 MMD = CMD exp(3 ln 2 σ g ) [2] Solid potassium sodium tartrate tetrahydrate (PST) generated by an ultrasonic atomizing nozzle was selected as the challenge aerosol. A liquid Dioctyl phthalate (DOP) was selected to measure impactor penetration characteristics with particles that could not exhibit bounce. To determine the effects of water solubility of the PST, a fluidized bed aerosol generator (model 3400A, TSI, Inc., Minneapolis, MN, USA) was used to generate water-insoluble polymethyl methacrylate (PMMA) powder. Before the aerosols were introduced into the test chamber, the aerosol output from the generator was dried using filtered compressed air and then neutralized to the Boltzmann charge equilibrium by passing the aerosols through an annular 10 mci Am-241 radioactive source (Figure 2). The size distribution of challenge aerosols was set to a CMD of 5.86 µm, with a GSD of about 1.56, to yield a complete separation curve over the size range of interest. A mass concentration of PST of about 7.22 mg/m 3 was generated to show a severe particle loading situation. The mass concentration of PST loading was decided based on NIOSH and US-EPA standards. For example, the 8-h time-weighted average (TWA) of water-soluble silicon carbide (non-fibrous) is 10 mg/m 3, and the respirable fraction is 5 mg/m 3 (NIOSH 1994). Moreover, the US-EPA has set primary (health-related) and secondary (welfare-related) National Ambient Air Quality Standards (NAAQS) for particulate matter. The 24-h average mass concentration of PM 10 is 125 µg/m 3 (US EPA 2006). Additionally, the mass concentration of PMMA generated by the fluidized bed aerosol generator was about 14.1 mg/m 3 (the PMMA generation was not simultaneous with PST/DOP generation). The APS was also utilized to measure the aerosol number concentrations and the size distributions of the test samplers. After the upstream aerosol concentration was measured using a reference sampling probe, the downstream aerosol concentration was measured using the test sampler. RESULTS AND DISCUSSION Figure 3 plots the variability of aerosol penetrations of a multi-hole impactor assembled with a conventional flat aluminum impaction plate or an open cavity. Each penetration curve indicates that the multi-hole impactor exhibited severe particle bounce when there was no flat-ring aluminum plate (open cavity FIG. 3. Variability of PST particle penetrations of a multi-hole impactor (sampling flow rate: 3.6 L/min) assembled with a conventional flat aluminum impaction plate or an open cavity. only) and challenged with solid PST particles (with no silicone oil coating on open cavity). For particles larger than 4.5 µm, particle bounce resulted in 20 65% overestimation of penetration. Similar experimental results were obtained even when the open cavity of the multi-hole impactor body was coated with silicone oil (viscosity, 100 mpa.s at 20 C; density, 0.98 g/ml). The designation of the open cavity in this study was not similar to earlier investigations (Scott and Ranz 1976; Biswas and Flagan 1988; Tsai and Cheng 1995; Chang et al. 1999). The dimensions of the open cavity were based on ease of use and were different from those used elsewhere (Figure 1), facilitating assembly of the flat-ring aluminum plate and filling the TSA. When the flat-ring aluminum plate was assembled with the open cavity and coated with silicone oil, no particle bounce from the plate occurred. However, long-term heavy particle loading remained a challenge, as described below. The main distinction between liquid and solid particles is the tendency of aerosol particles to bounce off an impactor as a function of particle size. Impactors typically experience particle bounce while collecting solid aerosols; however, liquid DOP aerosols are not expected to bounce. The liquid challenge DOP aerosol was used to demonstrate non-bounce separation curves, yielding a complete separation curve for a multi-hole impactor for comparison with the solid PST challenge aerosol. Figure 4 plots the variability of aerosol penetrations of the multi-hole impactor versus different challenge aerosols and different impaction mediums. The cut-off size of the multi-hole impactor was approximately 4 µm; however, the penetration-curve slope was steeper than the ISO/CEN/ACGIH respirable curve when the multi-hole impactor was challenged with PST or DOP particles. In this investigation, however, the multi-hole impactor was developed to demonstrate the method for reducing particle bounce and loading.
6 118 C.-Y. LAI ET AL. FIG. 4. Variability of aerosol penetrations of multi-hole impactor (sampling flow rate: 3.6 L/min) versus different challenge aerosols and different impaction media. As described, research studies have established that an impaction substrate coated with an adhesive material can reduce particle bounce and re-entrainment. However, following longterm particle loading, the adhesive material cannot continue to prevent incoming particles from bouncing off the impaction plate. Regardless of which adhesive material is used, incoming particles rebound off previously deposited particle layers. The TSA was prepared with water or other solvents with weak chemical bonds such that the discharge of water (aqueous layer) or solvent from TSA could dissolve incoming soluble particles, consequently minimizing particle bounce. The separation curve (Figure 4) obtained when 3% TSA was present in the open cavity, agrees closely with that obtained when the multi-hole impactor was challenged with solid water soluble PST particles: no particles bounced off the soft TSA jelly, as in the case when the flat-ring aluminum plate was coated with silicone oil. FIG % of TSA exhibited superior efficiency in reducing PST particle bounce using a multi-hole impactor (sampling flow rate: 3.6 L/min). According to experimental results (Figure 5), 1 6% of TSA exhibited superior efficiency in reducing PST particle bounce. Nevertheless, a mass concentration of TSA of <1% or >6% was difficult to prepare. Notably, TSA at <1% was excessively soft and could not maintain its shape, while TSA at >6% was rigid and its consistency so firm that it could not be used to fill the impactor open cavity. In view of the fact that TSA is commonly prepared using hot water and continues discharging water due to its weak bond with water, long-term sampling of flowing air may blow away discharged water (aqueous layer) and accelerate TSA dehydration. Therefore, using a high concentration of TSA to fill the open cavity is difficult. Particles were loaded for 100 min to compare impaction media and coating materials using a multi-hole impactor (Figure 6). The top-left plot in Figure 6 refers to long-term heavy particle loading when the multi-hole impactor was equipped with a flatring aluminum plate. The CMD of the challenge PST aerosols was 5.86 µm with a GSD of 1.56, and the mass concentration of PST was around 7.22 mg/m 3. The closed symbols in Figure 6 represent the initial sampling separation curve of the impactor, and the open symbols represent the sampling separation curve of the impactor obtained after 100 min of particle loading. Particles bounce was initially severe after 100 min of sampling when the aluminum plate was not coated with silicone oil. As expected, solid PST particles initially stuck to the impaction plate; however, the particles bounced after 100 min of sampling (in contrast to the sampling separation curve (Figure 3)), when the aluminum plate was coated with silicone oil (top right plot in Figure 6). Solid water soluble PST particles were dissolved on the aqueous layer of TSA-filled plate before loading; however, significant particle bouncing occurred after 100 min of sampling, even when 3% TSA-filled plate was used (left lower plot in Figure 6). The particles bounced and reduced collection efficiency, perhaps because of TSA dehydration after 100 min of sampling. The TSA had shrunk when the TSA-filling cavity was observed. The solid PST directly bounced off the open cavity. Since the distance between the nozzle and impaction surface was reduced, the cut-size and penetration curve, as expected, shifted to a smaller size after particle loading. Therefore, the penetration of small particles decreases as loading increases. However, penetration of large particles increases as loading increases due to bouncing particles. Thereafter, the TSA-filling cavity was coated with a thin layer of silicone oil to prevent dehydration of TSA due to air flow. Solid soluble PST penetrated the silicone layer and was dissolved in the aqueous layer formed between the silicone and TSA. The silicone-tsa double layer minimized PST particle bounce and long-term particle loading (lower right plot in Figure 6). In this study, from the upstream and downstream aerosol concentrations measured by APS, the estimated total loaded PST particle mass for the multi-hole impactor was about 3.09 mg for a 100-min loading. The 100-min loading time for the experiment was decided based on the test system stability and the sampling strategy. Since the mass concentration of challenge aerosol is
7 REDUCING PARTICLE BOUNCE AND LOADING EFFECT 119 FIG. 6. The PST particles were loaded for 100 min to compare impaction media and coating materials using a multi-hole impactor (sampling flow rate: 3.6 L/min; The CMD of challenge PST particles was 5.86 µm with a GSD of 1.56, and the mass concentration of PST was around 7.22 mg/m 3 ). about 7.22 mg/m 3, loading time should not be excessively long to maintain APS sampling efficiency. As incoming particles are always soluble in TSA medium, water solubility dominates the particle loading capacity. Furthermore, for sampling the particle burden in work environments, an 8-h sampling period can be divided into several continuous sampling periods. For sampling ambient environments unburdened with particles, a superior thermostability silicone oil can be used to extend sampling time for a silicone-tsa double layer. Notably, TSA concentrations of 1, 3, and 6% were compared for long-term particle loading to elucidate the effect of TSA dehydration and the effect of using a silicone-tsa double layer. Figure 7 plots the PST aerosol penetration at 5 µm during the 100-min sampling versus time in each loading scenario. Previous penetration results in this study show that the amount of PST aerosol that had penetrated at 5 µmwas zero when the flatring aluminum plate or TSA-filling was used. Consequently, as particle bouncing occurred, and particle penetration increased was apparent in experimental data. The PST aerosol bouncing at 5 µm from the aluminum plate was 20 33% without a coating of silicon oil on the plate. The bare flat plate was responsible for 33% of particle bounce, as no sticky material was present to capture the 5 µm PST particles. However, the percentage of particles bouncing decreased and stabilized after loading for 20 min, perhaps because incoming particles impacted on existing particle layers. The surfaces coated with oil increased adhesion energy, promoted deformation, and dissipated energy, thereby reducing particle bounce. Conversely, the silicone oil layer was too thin to reduce long-term particle loading. Experimental results similar to the bare flat plate were obtained after 20 min of loading: incoming particles impacted previously deposited particle layers, leading to a particle bounce of 20%. Moreover, TSA discharged water and shrunk rapidly when subjected to air flow. Three concentrations of TSA-filling 1, 3, and 6% and two sampling conditions coated with silicone oil and uncoated were compared for long-term particle loading. No particle bounce occurred for the plates filled with 1, 3, and 6% TSA when TSA-filled plate surface was coated with silicone oil. The
8 120 C.-Y. LAI ET AL. FIG. 7. The PST particle penetration of 5 µm during the 100 min sampling against time in each loading situation using a multi-hole impactor (sampling flow rate: 3.6 L/min). 700-µm-thick silicone oil, in the silicone-tsa double layer, significantly resisted dehydration from the TSA-filled plate. Additionally, when PST particles impacted the layer between the TSA and silicone oil, PST was dissolved in water discharged from TSA. However, this discharged water was not blown away by air flow due to the silicone coating the TSA surface. In contrast, the three TSA concentrations were associated with various degrees of 5-µm particle bounce when the TSA-filled plate was not coated with silicone oil. For 1% TSA, PST particle bounce was observed after approximately 40 min as the air flow blew away discharged water. Similar experimental results were observed for 3 and 6% TSA; the PST particles rebounded in approximately 23 and 5 min, respectively. The increased penetration for each TSA concentration varied with repeated sampling, probably because the shapes of the shrunk TSA differed. However, the effective time associated with decreased PST particle bounce was similar in all cases. A PEM-PM 2.5 sampler was employed to confirm the effectiveness of the TSA filling. In this experiment, the PEM-PM 2.5 impactor was expected to exhibit particle bounce as it collected solid PST aerosols when no adhesive coating was present. For particles >3 µm, particle bounce was overestimated by 5 15% during solid PST particle sampling (Figure 8). Conversely, when the porous metal plate was coated with silicone oil and particle loading was minimal, no particles bounced off the porous plate of the PEM-PM 2.5 impactor. The cut-off size of the PEM-PM 2.5 sampler was around 2.5 µm (Figure 8); however, the penetration curve slope exceeded that of the US-EPA PM 2.5 curve when the PEM-PM 2.5 sampler was challenged with PST or DOP particles. The CMD of challenge PST aerosols was 5.86 µm with a GSD of 1.56, and the mass concentration of PST was around 7.22 mg/m 3. The TSA-filling process was conducted by removing the original porous metal plate from the PEM-PM 2.5 impactor and replacing it with 3% TSA. Under minimal particle FIG. 8. A PEM-PM 2.5 sampler was employed to validate the application of TSA-filling. loading, no particle bounce was observed with 3% TSA, however, a 100-min particle loading could not be achieved because of TSA dehydration (Figure 9). The TSA discharged water and shrank rapidly when exposed to air flow. Conversely, no other particle-rebound effects were observed when a silicone-tsa double layer was used as the impaction plate and applied to the PEM-PM 2.5 sampler during 100 min of sampling. As expected, solid soluble PST was dissolved in the aqueous layer formed between the silicone and TSA. The estimated total loaded PST particle mass of the PEM-PM 2.5 sampler was about 8.66 mg for a 100-min loading. The severe case of particle loading involved the silicone- TSA double layer and water insoluble PMMA aerosols (Figure 10). The CMD of the PMMA aerosols was 5.17 µm with a GSD of about The mass concentration of PMMA was FIG. 9. The silicone-tsa double layer was compared with only TSA-filling using a PEM-PM 2.5 impactor (sampling flow rate: 10 L/min; loading PST particles for 100 min).
9 REDUCING PARTICLE BOUNCE AND LOADING EFFECT 121 FIG. 10. The severe case involved the silicone-tsa double layer and solid insoluble PMMA aerosols using a multi-hole impactor (The CMD of challenge PST aerosols was 5.86 µm with a GSD of 1.56, and the mass concentration of PST was around 7.22 mg/m 3. The CMD of the PMMA aerosols was 5.17 µm with a GSD of about The mass concentration of PMMA was approximately 14.1 mg/m 3 ). generated by the fluidized bed aerosol generator at approximately 14.1 mg/m 3, illustrating the severe particle loading situation. The silicone oil in the silicone-tsa double layer was a moisture-conserving structure that resisted dehydration from the TSA-filled plate (Figure 7). The water soluble PST was dissolved by aqueous layer discharged from TSA. However, the silicone-tsa double layer could not dissolve PMMA, which is water insoluble. When 3% TSA coated with silicone oil was used to collect PMMA, the insoluble PMMA bounced off the TSA-filled plate in the multi-hole impactor, resulting in a 20% overestimation of penetration during PMMA sampling. The estimated total loaded PMMA particle mass of the multi-hole impactor was about 4.87 mg for a 100-min loading. In order to show the differences in loading tendency between soluble and insoluble particles, the PST loading results were also plotted in Figure 10, despite the differences in total loading (3.09 mg total vs for 100 min). Even when the 0.5% TSA was used to minimize PMMA bounce, penetration overestimation was still 10% (estimated total loaded PMMA particle mass of the multi-hole impactor was about 5.48 mg for a 100-min loading). The incoming PMMA particles impacted on hundreds of exposed layers of previously deposited particles. The 0.5% TSA was likely a soft impaction plate; however, the 0.5% TSA was not prepared easily and did not effectively reduce PMMA particle bounce and long-term heavy particle loading. Numerous experimental studies show that under heavy particle loading, low viscosity oil reduces bounce. This capacity is attributable to capillary action through which collected particles are covered with oil; thus, incoming particles are ideally always in contact with the coated plate. However, low-viscosity oil is ineffective for long-term particle loading, especially in a particle-burden situation. The silicone oil was not effectively wicked up via capillary action through previously deposited particles. Since the deposited particles were always accumulated on the impaction plate surface, the silicone oil had limited capillary action. Moreover, low viscosity oil may not be convenient for personal sampling especially when the subject is moving and the sampler may tilt or shake. Alternatively, a commonly used, soft, semi-solid culture medium, TSA, can be used as an impaction plate. If incoming particles are water-soluble, the TSA water solubility determines particle loading capacity. Experimental results demonstrate that the bouncing effect and heavy particle loading of solid particles was minimized by using TSA in the open cavity as a replacement for a conventional impaction plate. Three concentrations of TSA (1, 3 and 6%) were associated with various degrees of 5 µm particle bounce when the TSA-filled plate was not coated with silicone oil (Figure 7). With 1% TSA, the PST particles rebounded in approximately 40 min because the air flow blew away the released water. Similar experimental results were observed for 3 and 6% TSA, where PST particles rebounded in approximately 23 and 5 min, respectively. However, TSA frequently discharged water due to weak chemical bonding; consequently, the air flow rapidly blew away water discharged from the TSA-filled plate during long-term sampling. To prevent TSA dehydration, silicone oil was coated on the surface of the TSA-filled plate as a moisture conservation technique and, thus, a silicone-tsa double layer was created. When a multi-hole impactor and commercial PEM-PM 2.5 impactor were combined with a silicone-tsa double layer in the open cavity as a replacement for the impaction plate, solid particle bounce and long-term heavy particle loading were reduced, as solid soluble PST penetrated the silicone layer and was dissolved in the aqueous layer formed between the silicone and TSA. Unlike PST, water-insoluble PMMA bounced off the 3% TSA-filled plate in the multi-hole impactor. The incoming PMMA particles impacted on hundreds of exposed insoluble PMMA particle layers, resulting in a 20% penetration overestimation during PMMA sampling. In conclusion, the TSA-filled open cavity can be used to reduce particle bounce and heavy particle loading, since TSA can be prepared using water or another solvent, and the water or solvent discharged from TSA can be used to dissolve particles, thereby minimizing particle bounce. Different solvents can be used to dissolve particles depending on particle composition. The two-layer structure, comprising a solvent-conserving layer and solvent-releasing layer, can be employed to reduce particle bounce and heavy particle loading. However, these novel techniques must be used carefully in ambient sampling at near freezing temperatures. Although antifreeze can be added to the solvent-releasing layer, further experimental proof is required. REFERENCES Biswas, P. and Flagan, R. C. (1988). The Particle Trap Impactor, J. Aerosol Sci. 19:
10 122 C.-Y. LAI ET AL. Chang, M., Kim, S., and Sioutas, C. (1999). Experimental Studies on Particle Impaction and Bounce: Effects of Substrate Design and Material, Atmos. Environ. 33: Chen, C. C., Lai, C. Y., Shih, T. S., and Yeh, W. Y. (1998). Development of Respirable Aerosol Samplers Using Porous Foams, Am. Ind. Hyg. Assoc. J. 59(11): Chen, C. C., Lai, C. Y., Shih, T. S., and Hwang, J. S. (1999). Laboratory Performance Comparison of Respirable Samplers, Am. Ind. Hyg. Assoc. J. 60: Dzubay, T. G. Hines, L. E., and Stevens, R. K. (1976). Particle Bounce Errors in Cascade Impactors, Atmos. Environ. 100: Esmen, N. A., and Lee, T. C. (1980). Distortion of Cascade Impactor Measured Size Distribution Due to Bounce and Blow-Off, Am. Ind. Hyg. Assoc. J. 41: Hinds, W. C. (1999). Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles. 2nd ed. John Wiley and Sons, Inc., New York. Kenny, L. C. and Liden, G. (1991). Comparison of Measured Respirable Dust Sampler Precision Curves with Sampling Convention, Ann. Occup. Hyg. 35: Lai, C. Y. and Chen, C. C. (2000). Performance Characteristics of PM 10 Samplers under Calm Air Condition, J. Air & Waste Management Assoc. 50: Lai, C. Y., Chen, C. C., and Hwang, J. S. (2002). Overall Performance Evaluation of Aerosol Pre-classifier, Adapter and Aerosol Number Samplers, Aerosol Sci. Technol. 36: Lidcn, G. and Kenny, L. (1992). The performance of respirable dust samplers: Sampler bias, precision and inaccuracy, Ann. Occup. Hyg. 36(1):1 22. Liden, G. and Kenny, L. C. (1994). Errors in inhalable dust sampling for particles exceeding 100 micrometres, Ann. Occup. Hyg. 38: Markowski, G. R. (1984). Reducing blowoff in cascade impactor measurements, Aerosol Sci. Technol. 3: Marple, V. A., Rubow, K. L., and Behm, S. M. (1991). A microorifice uniform deposit impactor (MOUDI): description, calibration, and use, Aerosol Sci. Technol. 14: National Institute for Occupational Safety and Health (NIOSH). (1994). International Chemical Safety Cards: ipcsneng/neng1061.html. Newton, G. J., Cheng, Y. S., Barr, E. B., and Yeh, H. C. (1990). Effects of collection substrates on performance and wall losses in cascade impactor, J. Aerosol Sci. 21: Pak, S. S., Liu, B. Y. H., and Rubow, K. L. (1992). Effect of Coating Thickness on Particle Bounce in Inertial Impactors, Aerosol Sci. Technol. 16: Rao, A. K. and Whitby, K. T. (1978a). Non-Ideal Collection Characteristics of Inertial Impactors I. Single-State Impactors and Solid Particles, J. Aerosol Sci. 9: Rao, A. K. and Whitby, K. T. (1978b). Non-Ideal Collection Characteristics of Inertial Impactors II. Cascade Impactors, J. Aerosol Sci. 9: Reischi, G. P., and John, W. (1978). The collection efficiency of impaction surfaces: A new impaction surface, Staub-Reinhaltungder Luft 38:55. Robert W. V., Thomas M. P., Sanjay N., Michael P. T., David B. G., and Russell W. W. (2001). Sensitivity Analysis of the USEPA WINS PM2.5 Separator, Aerosol Sci. Technol. 34(5): Scott, J. H. and Ranz, W. E. (1976). Jet-cone impactors as aerosol particle separators, Environ. Sci. Technol. 10: Tsai, C. J. and Cheng, Y. H. (1995). Solid particle collection characteristics on impaction surface of different design, Aerosol Sci. Technol. 23: Tsai, C. J. and Shih T. S. (1995). Particles Collection Efficiency of Two Personal Respirable Dust Samplers, Am. Ind. Hyg. Assoc. J. 56(9): Turner, J. R., and Hering, S. V. (1987). Greased and oiled substrate as bouncefree impaction surfaces, J. Aerosol Sci. 18: U.S. Environmental Protection Agency (US-EPA). (2006). reg5oair/naaqs/pm.htm.
USING THE ELECTRET FILTER TO REMOVE THE SUBMICRON AEROSOLS
USING THE ELECTRET FILTER TO REMOVE THE SUBMICRON AEROSOLS SH Yang 1,*, GWM Lee 1, CH Luo 2, CC Wu 1, KP Yu 1, CL Lou 1 1 Graduate Institute of Environmental Engineering, National Taiwan University, 71,
More informationParticle Collection and Concentration for Cyclone Concentrators
Aerosol Science and Technology, 39:113 123, 2005 Copyright c American Association for Aerosol Research ISSN: 0278-6826 print / 1521-7388 online DOI: 10.1080/027868290907138 Particle Collection and Concentration
More informationPLEASE SCROLL DOWN FOR ARTICLE. Full terms and conditions of use:
This article was downloaded by: [National Taiwan University] On: 16 September 2010 Access details: Access Details: [subscription number 917274887] Publisher Taylor & Francis Informa Ltd Registered in England
More informationParticle Impaction Patterns from a Circular Jet
Aerosol Science and Technology ISSN: 0278-6826 (Print) 1521-7388 (Online) Journal homepage: http://www.tandfonline.com/loi/uast20 Particle Impaction Patterns from a Circular Jet Virendra Sethi & Walter
More informationMEASURING NANOPARTICLE EXPOSURE
MEASURING NANOPARTICLE EXPOSURE APPLICATION NOTE NSAM-001 The Nanoparticle Surface Area Monitor reports the surface area of inhaled particles deposited in the lung Nanoparticle Exposure There is increasing
More informationJournal of Energy and Environmental Sustainability. Design and Development of a Novel PM Inertial Impactor With Reduced Particle Bounce Off
20 Biswas Journal & of Gupta Energy / Journal and Environmental of Energy and Environmental Sustainability, Sustainability, 3 (2017) 20-24 3 (2017) 20-24 Journal of Energy and Environmental Sustainability
More informationEstimation of Mass with the Model 3321 APS Spectrometer
Particle Sizers Estimation of Mass with the Model 3321 APS Spectrometer Application Note APS-001 Introduction Particle size and mass are two important parameters that are often used to characterize an
More informationPenetration of 4.5 nm to 10 μm aerosol particles through fibrous filters
Aerosol Science 38 (2007) 719 727 www.elsevier.com/locate/jaerosci Penetration of 4.5 nm to 10 μm aerosol particles through fibrous filters Sheng-Hsiu Huang a, Chun-Wan Chen a, Cheng-Ping Chang a, Chane-Yu
More information58 Guinan St. Waltham, MA Ph.: Fx.: E mail:
BGI Incorporated 58 Guinan St. Waltham, MA 02451 Ph.: 781 891 9380 Fx.: 781 891 8151 E mail: bsk29@attglobal.net www.bgiusa.com Technical Report: Evaluation of a Sharp Cut Cyclone for PM 1 Sampling January
More informationDifferential Mobility Particle Sizer (Aerosol measurements)
Institute for Atmospheric and Climate Science - IACETH Atmospheric Physics Lab Work Differential Mobility Particle Sizer (Aerosol measurements) Abstract A differential mobility particle sizer (DMPS) is
More informationWhite Rose Research Online URL for this paper: Version: Accepted Version
This is a repository copy of A comparison of the sampling efficiency of bioaerosol samplers and particle counters in natural and controlled environments. White Rose Research Online URL for this paper:
More informationGeneration of monodisperse aerosols through condensation nuclei control
Air Pollution XV 505 Generation of monodisperse aerosols through condensation nuclei control H. M. Kadlimatti 1, S. Gangamma 2 & S. K. Varghese 3 1 Department of Mechanical Engineering, Basaveshwar Engineering
More informationGeneration and Evaluation of Monodisperse Sodium Chloride and Oleic Acid Nanoparticles
Generation and Evaluation of Monodisperse Sodium Chloride and Oleic Acid Nanoparticles Tzu Ming Chen, Hung Min Chein Energy & Environment Research Laboratories, Industrial Technology Research Institute,
More informationPublished online: 30 Nov 2010.
This article was downloaded by: [National Chiao Tung University 國立交通大學 ] On: 27 April 2014, At: 18:58 Publisher: Taylor & Francis Informa Ltd Registered in England and Wales Registered Number: 1072954
More informationResponses of Low Pressure Andersen Sampler for Collecting Substrates
Responses of Low Pressure Andersen Sampler for Collecting Substrates K.Yamasaki 1, Y.Yamada 2, K.Miyamoto 2 and M.Shimo 2 1 Research Reactor Institute, Kyoto University Noda, Kumatori-cho, Sennan-gun,
More information28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies
DESIGN OF AEROSOL SAMPLER TO REMOVE RADON AND THORON PROGENY INTERFERENCE FROM AEROSOL SAMPLES FOR NUCLEAR EXPLOSION MONITORING Scot K. Waye, Steven R. Biegalski, and Ofodike A. Ezekoye The University
More informationNanoparticle Exposure in the Workplace
Nanoparticle Exposure in the Workplace Michele. L. Ostraat, Ph.D. RTI International September 11, 2012 Practical Workplace Issues Related to Setting & Using Engineered Nanomaterial OELs Lack of instrumentation/characterization
More informationPerformance Characterization of A New Cam System M.J. Koskelo 1, J.C. Rodgers 2, D.C. Nelson 2, A.R. McFarland 3 and C.A. Ortiz 3
Performance Characterization of A New Cam System M.J. Koskelo 1, J.C. Rodgers 2, D.C. Nelson 2, A.R. McFarland 3 and C.A. Ortiz 3 1 CANBERRA Industries, Meriden, CT 06450 2 Los Alamos National Laboratory,
More informationCharacter and Behavior of Mist Generated by Application of Cutting Fluid to a Rotating Cylindrical Workpiece, Part 2: Experimental Validation
J. Sun C. Ju Y. Yue K. L. Gunter D. J. Michalek J. W. Sutherland Dept. of Mechanical Engineering-Engineering Mechanics, Michigan Technological University, Houghton, MI 49931 Character and Behavior of Mist
More informationBGI Incorporated. 58 Guinan St. Waltham, MA Ph.: Fx.: E mail:
BGI Incorporated 58 Guinan St. Waltham, MA 02451 Ph.: 781 891 9380 Fx.: 781 891 8151 E mail: bsk29@attglobal.net www.bgiusa.com Technical Report: Evaluation of SCC and GK Type Personal Cyclones March 2000
More information429 LIGHT DIFFRACTION MEASUREMENT OF PARTICLE SIZE
Search USP29 429 LIGHT DIFFRACTION MEASUREMENT OF PARTICLE SIZE Light diffraction is one of the most widely used techniques for measuring the size of a wide range of particles from very fine to very coarse.
More informationENVR 116 Aerosol Technology Laboratory Session Fall 2005
ENVR 116 Aerosol Technology Laboratory Session Fall 2005 INSTRUMENT CALIBRATION USING PSL SPHERES The objective of this lab is to become familiar with the operation, characteristics, and limitations of
More informationGAW - WCCAP recommendation for aerosol inlets and sampling tubes
GAW - WCCAP recommendation for aerosol inlets and sampling tubes Alfred Wiedensohler, Wolfram Birmili, Leibniz Institute for Tropospheric Research, Leipzig, Germany John Ogren, NOAA ESRL GMD, Boulder,
More informationMODULE 4.3 Atmospheric analysis of particulates
MODULE 4.3 Atmospheric analysis of particulates Measurement And Characterisation Of The Particulate Content 1 Total particulate concentration 1 Composition of the particulate 1 Determination of particle
More informationParticle Bounce During Filtration of Particles on Wet and Dry Filters
Aerosol Science and Technology ISSN: 0278-6826 (Print) 1521-7388 (Online) Journal homepage: http://www.tandfonline.com/loi/uast20 Particle Bounce During Filtration of Particles on Wet and Dry Filters Benjamin
More informationImproving the Nanoparticle Resolution of the ELPI
Aerosol and Air Quality Research, 1: 36 366, 21 Copyright Taiwan Association for Aerosol Research ISSN: 168-8584 print / 271-149 online doi: 1.429/aaqr.29.1.6 Improving the Nanoparticle Resolution of the
More informationChapter 7 Separation of Particles from a Gas
Chapter 7 Separation of Particles from a Gas For either gas cleaning (removal of dusts) or recovery of particulate products Separation Mechanisms Sedimentation : Settling chamber, centrifuge Migration
More informationMODELING ON THE BREAKUP OF VISCO-ELASTIC LIQUID FOR EFFERVESCENT ATOMIZATION
1446 THERMAL SCIENCE, Year 2012, Vol. 16, No. 5, pp. 1446-1450 MODELING ON THE BREAKUP OF VISCO-ELASTIC LIQUID FOR EFFERVESCENT ATOMIZATION by Li-Juan QIAN * China Jiliang University, Hangzhou, China Short
More informationExperimental Study of Particle Deposition on Semiconductor Wafers
Aerosol Science and Technology ISSN: 0278-6826 (Print) 1521-7388 (Online) Journal homepage: http://www.tandfonline.com/loi/uast20 Experimental Study of Particle Deposition on Semiconductor Wafers David
More informationEvaluation of the NanoAerosol Generator by Kanomax FMT Inc. in Aerosolization of Size Standard Nanoparticle and Protein
Aerosol and Air Quality Research, 18: 549 554, 2018 Copyright Taiwan Association for Aerosol Research ISSN: 1680-8584 print / 2071-1409 online doi: 10.4209/aaqr.2017.09.0352 Technical Note Evaluation of
More informationCENG 501 Examination Problem: Estimation of Viscosity with a Falling - Cylinder Viscometer
CENG 501 Examination Problem: Estimation of Viscosity with a Falling - Cylinder Viscometer You are assigned to design a fallingcylinder viscometer to measure the viscosity of Newtonian liquids. A schematic
More informationCHAPTER 4 THERMAL CONDUCTIVITY AND VISCOSITY MEASUREMENTS
50 CHAPTER 4 THERMAL CONDUCTIVITY AND VISCOSITY MEASUREMENTS 4.1 INTRODUCTION In the development of any energy-efficient heat transfer fluids for enhanced heat transfer performance, in practical applications,
More informationA New Dielectrophoretic Coating Process for Depositing Thin Uniform Coatings on Films and Fibrous Surfaces
A New Dielectrophoretic Coating Process for Depositing Thin Uniform Coatings on Films and Fibrous Surfaces by Angelo Yializis Ph.D., Xin Dai Ph.D. Sigma Technologies International Tucson, AZ USA SIGMA
More informationSampling. Information is helpful in implementing control measures for reducing pollutant concentration to acceptable levels
Types of pollutant sampling and measurement: Air quality monitoring: Sampling and measurement of air pollutants generally known, as air quality monitoring. It is an integral component of any air pollution
More information115 Adopted:
115 Adopted: 27.07.95 OECD GUIDELINE FOR THE TESTING OF CHEMICALS Adopted by the Council on 27 th July 1995 Surface Tension of Aqueous Solutions INTRODUCTION 1. This updated version of the original guideline
More informationNumerical Modeling of Sampling Airborne Radioactive Particles Methods from the Stacks of Nuclear Facilities in Compliance with ISO 2889
Numerical Modeling of Sampling Airborne Radioactive Particles Methods from the Stacks of Nuclear Facilities in Compliance with ISO 2889 Author P. Geraldini Sogin Spa Via Torino 6, 00184 Rome Italy, geraldini@sogin.it
More informationNUMERICAL APPROACH TO INTER-FIBER FLOW IN NON-WOVENS WITH SUPER ABSORBENT FIBERS
THERMAL SCIENCE, Year 2017, Vol. 21, No. 4, pp. 1639-1644 1639 Introduction NUMERICAL APPROACH TO INTER-FIBER FLOW IN NON-WOVENS WITH SUPER ABSORBENT FIBERS by Zhi-Rong DING a*, Ying GUO a b, and Shan-Yuan
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 8426 Second edition 2008-02-01 Hydraulic fluid power Positive displacement pumps and motors Determination of derived capacity Transmissions hydrauliques Pompes et moteurs volumétriques
More informationENVR 116 Introduction to Aerosol Science December 17, 2001 FINAL EXAMINATION
ENVR 116 Introduction to Aerosol Science December 17, 2001 FINAL EXAMINATION Please answer all questions on the attached sheets Answer Question No. 1 and 4 of the remaining 6 questions. No extra credit
More informationFouling of HVAC Fin and Tube Heat Exchangers
LBNL-47668 Fouling of HVAC Fin and Tube Heat Exchangers Jeffrey Siegel and Van P. Carey Environmental Energy Technology Division Indoor Environment Department Lawrence Berkeley National Laboratory Berkeley,
More informationMobility-Based Particle Size Classification and Detection down to 2nm Theory to Practice
Mobility-Based Particle Size Classification and Detection down to 2nm Theory to Practice Robert C. Anderson Presented at SEMATECH November 12, 2012 Current and Future Defectively Issues from Components
More informationLaboratory 1: Calibration of a High-Volume Sampler
Laboratory 1 Laboratory 1: Calibration of a High-Volume Sampler 1.1 To the User of this Manual This manual has been prepared to guide the students through a series of laboratory exercises developed to
More informationWet Collectors. Type 1: Spray Chamber Scrubber 10/30/2013. EVE 402 Air Pollution Generation and Control. Chapter #5 Lectures (Part 5)
EVE 40 Air Pollution eneration and Control Chapter #5 Lectures (Part 5) Wet Collectors Water is used to either capture particulate or increase aerosol size Hygroscopic particles (those that attract and
More informationPerformance of a Venturi Scrubber in the removal of fine powder. from a confined gas stream
Performance of a Venturi Scrubber in the removal of fine powder from a confined gas stream M.A. Martins Costa 1, A.P. Ribeiro 1, E.G. Tognetti 2, M.L. Aguiar 3, J.A.S. Gonçalves 3, J.R. Coury 3* 1 Doctoral
More informationEnvironmental control systems for defining the activity size distribution of radioactive aerosols - a case study
Environmental control systems for defining the activity size distribution of radioactive aerosols - a case study Alexandra Ioannidou Aristotle University of Thessaloniki, Physics Department, Nuclear Physics
More informationSupporting Information. Copyright Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim, 2008
Supporting Information pyright Wiley-VCH Verlag GmbH &. KGaA, 69451 Weinheim, 2008 Time-Evolving Self-rganization and Autonomous Structural Adaptation of balt(ii) rganic Framework Materials with Nets scu
More informationEnhancing the Performance of Organic Thin-Film Transistor using a Buffer Layer
Proceedings of the 9th International Conference on Properties and Applications of Dielectric Materials July 19-23, 29, Harbin, China L-7 Enhancing the Performance of Organic Thin-Film Transistor using
More informationMechanisms of Vortex Oscillation in a Fluidic Flow Meter
Vol. THE UNIVERSITY OF CENTRAL FLORIDA Published November 2, 2017 Mechanisms of Vortex Oscillation in a Fluidic Flow Meter By: Mohammed Al-Muqbel and Peshala Gamage Faculty Mentor: Dr. Hansen Mansy UCF
More informationDirect reading aerosol monitors
Health and Safety Executive Direct reading aerosol monitors 27 th June 2018 Andrew Thorpe Introduction Direct reading Aerosol Monitors (DRAMs) are often used as a complementary approach to conventional
More informationAn analytical model for the fractional efficiency of a uniflow cyclone with a tangential inlet
Available online at www.sciencedirect.com Powder Technology 83 (2008) 47 5 www.elsevier.com/locate/powtec An analytical model for the fractional efficiency of a uniflow cyclone with a tangential inlet
More informationA Novel Optical Instrument for Estimating Size Segregated Aerosol Mass Concentration in Real Time
Aerosol Science and Technology ISSN: 0278-6826 (Print) 1521-7388 (Online) Journal homepage: http://www.tandfonline.com/loi/uast20 A Novel Optical Instrument for Estimating Size Segregated Aerosol Mass
More informationMonitoring of Airborne Nanoparticles in Research Laboratories at the Center for High-Rate Nanomanufacturing (CHN)
Monitoring of Airborne Nanoparticles in Research Laboratories at the Center for High-Rate Nanomanufacturing (CHN) Candace Sujung Tsai, doctoral candidate Dept. of Work Environment University of Massachusetts
More informationSpark-Induced Breakdown Spectroscopy (SIBS) Analysis for Detection of Hazardous Airborne Biologicals
VG6-276 Spark-Induced Breakdown Spectroscopy (SIBS) Analysis for Detection of Hazardous Airborne Biologicals A.J.R. Bauer*, D.M. Sonnenfroh, and S.J. Davis Physical Sciences Inc. Andover, MA 181 USA Presented
More informationStudy on Impingement of Air Jet from Orifice on Convex Surface for Unconfined Flow
Study on Impingement of Air Jet from Orifice on Convex Surface for Unconfined Flow Prof. A. M. Hanchinal 1 Krishna Alias Aditya B. 2 Rahul Torgal 3 Naveed Sudarji 4 Aishwarya Chhapre 5 2, 3, 4, 5 UG Students
More informationA Numerical Estimate of Flexible Short-Tube Flow and Deformation with R-134a and R-410a
For personal use only. Additional reproduction, distribution, or transmission SL-08-043 A Numerical Estimate of Flexible Short-Tube Flow and Deformation with R-134a and R-410a Ramadan Bassiouny, PhD Dennis
More informationChapter 1. Introduction
Chapter 1. Introduction 1-1 1.1. Overview In the past twenty years, charged droplets and strong electric fields have quietly revolutionized chemistry. In combination with an atmospheric-sampling mass spectrometer,
More informationGeneral Chemistry I CHEM-1030 Laboratory Experiment No. 2 Physical Separation Techniques
General Chemistry I CHEM-1030 Laboratory Experiment No. 2 Physical Separation Techniques Introduction When two or more substances that do not react chemically are blended together, the components of the
More information9. Hydroboration-Oxidation of Alkenes
9. ydroboration-xidation of Alkenes A. Introduction 1. ydroboration-xidation of Alkenes Alkenes can be oxidized to alcohols using a two-step method of hydroboration followed by oxidation. The first step
More informationStability Analysis of Landslide Dam under Rainfall
Stability Analysis of Landslide Dam under Rainfall Pei-Hsun Tsai, Zheng-Yi Feng 2, Fan-Chieh Yu 3 and Jian-Han Lin 4 Associate Professor, Department of Construction Engineering, Chaoyang University of
More informationAn Aerosol Generator for High Concentrations of µm Solid Particles of Practical Monodispersity
Aerosol Science and Technology ISSN: 0278-6826 (Print) 1521-7388 (Online) Journal homepage: http://www.tandfonline.com/loi/uast20 An Aerosol Generator for High Concentrations of 0.5 5-µm Solid Particles
More informationPIC/MCC Simulation of Radio Frequency Hollow Cathode Discharge in Nitrogen
PIC/MCC Simulation of Radio Frequency Hollow Cathode Discharge in Nitrogen HAN Qing ( ), WANG Jing ( ), ZHANG Lianzhu ( ) College of Physics Science and Information Engineering, Hebei Normal University,
More informationA New Monodisperse Droplet Generator and its Applications
ILASS Americas 28th Annual Conference on Liquid Atomization and Spray Systems, Dearborn, MI, May 2016 A New Monodisperse Droplet Generator and its Applications H. Duan, F. Romay, Z. Syedain, B. Y. H. Liu
More informationSupplementary Information. In colloidal drop drying processes, multi-ring depositions are formed due to the stick-slip
Electronic Supplementary Material (ESI for Soft Matter. This journal is The Royal Society of Chemistry 14 Supplementary Information A1. Contact line receding velocity of an evaporating drop In colloidal
More informationExperimental study of CO 2 releases from a saturated liquid reservoir
Available online at www.sciencedirect.com Energy Procedia 37 (213 ) 4818 4824 GHGT-11 Experimental study of CO 2 releases from a saturated liquid reservoir S. Toesse 1*, K. Vaagsaether 1, J. Lundberg 1,
More informationSupersonic air and wet steam jet using simplified de Laval nozzle
Proceedings of the International Conference on Power Engineering-15 (ICOPE-15) November 30- December 4, 2015, Yokohama, Japan Paper ID: ICOPE-15-1158 Supersonic air and wet steam jet using simplified de
More informationIntroduction. Sample kit content
Introduction Polymer blend sample preparation TN01062 Preparation of polymer samples available from the Lateral force, Phase imaging, and Force modulation mode kits The SBS-PMMA, SBS-PS, and SBR-PMMA samples
More informationProduction of particle powder for inhalation process and controlled release of drugs
Production of particles used to inhalation process and controlled release of drugs Proceedings of European Congress of Chemical Engineering (ECCE-6) Copenhagen, 16-20 September 2007 Production of particle
More informationMeasurement of Particle Density by Inertial Classification of Differential Mobility Analyzer Generated Monodisperse Aerosols
Aerosol Science and Technology SSN: 0278-6826 (Print) 1521-7388 (Online) Journal homepage: http://www.tandfonline.com/loi/uast20 Measurement of Particle Density by nertial Classification of Differential
More informationResearch and Development of Parylene Thin-Film Deposition and Application for Water-Proofing
Advanced Materials Research Online: 2012-06-14 ISSN: 1662-8985, Vols. 538-541, pp 23-28 doi:10.4028/www.scientific.net/amr.538-541.23 2012 Trans Tech Publications, Switzerland Research and Development
More informationVIBRATING ORIFICE AEROSOL GENERATOR MODEL 3450
VIBRATING ORIFICE AEROSOL GENERATOR MODEL 3450 CREATES MONODISPERSE PARTICLES FROM 1 TO 200 MICROMETERS IN DIAMETER Uniform particle creation is critical for successful aerosol research. Controlled experiments
More informationCutting Fluid Effects on Machine Shop Air Quality
Cutting Fluid Effects on Machine Shop Air Quality For IAB000 Zhong Chen Advisor: Dr. Steven Y. Liang Oct. 18, 000 Problem Description Occupational Safety and Health Administration (OSHA) requirements 0.5
More information6.5 Optical-Coating-Deposition Technologies
92 Chapter 6 6.5 Optical-Coating-Deposition Technologies The coating process takes place in an evaporation chamber with a fully controlled system for the specified requirements. Typical systems are depicted
More informationA Field Evaluation of the BGI and Cowl Type Gravimetric Samplers
A Field Evaluation of the BGI and Cowl Type Gravimetric Samplers By B. K. Belle, J.J.L. Du Plessis and J.W. Oberholzer. Summary After initial studies by the CSIR indicating that a discrepancy exists in
More informationHydraulic Fundamentals Hydraulics Definition Advent of Oil Hydraulics Pascal s Law Pressure
Fluidsys Training Centre, Bangalore offers an extensive range of skill-based and industry-relevant courses in the field of Pneumatics and Hydraulics. For more details, please visit the website: https://fluidsys.org
More informationCOPLEY S C I E N T I F I C. A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for:
A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for: generating monodisperse aerosol by mobility classification with automatic concentration detection
More informationCHARACTERISTIC DISTRIBUTION OF SUBMICRON AND NANO-PARTICLES LADEN FLOW AROUND CIRCULAR CYLINDER
1386 THERMAL SCIENCE, Year 2012, Vol. 16, No. 5, pp. 1386-1390 CHARACTERISTIC DISTRIBUTION OF SUBMICRON AND NANO-PARTICLES LADEN FLOW AROUND CIRCULAR CYLINDER by Cheng-Xu TU a,b* and Jian ZHANG b a Department
More informationStandard Test Method for Thermal Conductivity of Refractories 1
Designation: C 201 93 (Reapproved 1998) Standard Test Method for Thermal Conductivity of Refractories 1 This standard is issued under the fixed designation C 201; the number immediately following the designation
More informationAME Model. (1) Rated flow (l/min (ANR)) Port size (Nominal size B) Weight (kg)
Super Mist Separator Series AME Series AME separates and absorbs aerosol state fine oil particles in compressed air and changes the oil lubricating compressed air to oilless equivalent air. It should be
More informationEvaluation of the Characteristic of Adsorption in a Double-Effect Adsorption Chiller with FAM-Z01
Journal of Materials Science and Chemical Engineering, 2016, 4, 8-19 http://www.scirp.org/journal/msce ISSN Online: 2327-6053 ISSN Print: 2327-6045 Evaluation of the Characteristic of Adsorption in a Double-Effect
More informationLab 4 Major Anions In Atmospheric Aerosol Particles
Georgia Institute of Technology School of Earth and Atmospheric Sciences EAS 4641 Spring 2008 Lab 4 Major Anions In Atmospheric Aerosol Particles Purpose of Lab 4: This experiment will involve determining
More informationSodium Chloride - Analytical Standard
Sodium Chloride - Analytical Standard Determination of Arsenic Former numbering: ECSS/CN 312-1982 & ESPA/CN-E-105-1994 1. SCOPE AND FIELD OF APPLICATION The present EuSalt Analytical Standard describes
More informationSimultaneous Sampling of Gas- and Aerosol-Phase TDI with a Triple Filter System
TECHNICAL PAPER ISSN 1047-3289 J. Air & Waste Manage. Assoc. 53:1265 1272 Copyright 2003 Air & Waste Management Association Simultaneous Sampling of Gas- and Aerosol-Phase TDI with a Triple Filter System
More informationConsolidation. Hsin-yu Shan Dept. of Civil Engineering National Chiao Tung University
Consolidation Hsin-yu Shan Dept. of Civil Engineering National Chiao Tung University Some Definitions Settlement: change in elevation Compression: change in thickness settlement S i = compresseion of layer
More informationModel 3450 Vibrating Orifice Aerosol Generator
Particle Instruments Model 3450 Vibrating Orifice Aerosol Generator Creates monodisperse particles from 1 to 200 micrometers in diameter Uniform particle creation is critical for successful aerosol research.
More informationCalcimeter. Meet the difference. Manual. T E I
Calcimeter Manual Meet the difference Eijkelkamp Soil & Water Nijverheidsstraat 30 NL-6987 EM Giesbeek T +31 313 880 200 E info@eijkelkamp.com I www.eijkelkamp.com 1 2018-05 M-0853E Contents On these operating
More informationParticle Size of Radioactive Aerosols Generated During Machine Operation in High-energy Proton Accelerators
Particle Size of Radioactive Aerosols Generated During Machine Operation in High-energy Proton Accelerators Yuichi Oki, Akira Endo 2, Yukio Kanda and Kenjiro Kondo Radiation Science Center, High Energy
More informationASSESSMENT OF SUSPENDED DUST FROM PIPE RATTLING OPERATIONS
ASSESSMENT OF SUSPENDED DUST FROM PIPE RATTLING OPERATIONS A Dissertation by JU-MYON PARK Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements
More informationSampling parameter effect on the particle size distribution during controlled dilution
Sampling parameter effect on the particle size distribution during controlled dilution E. Lamminen, P. Mikkanen, J. Ojanen / DEKATI, Tampere ABSTRACT Fine Particle Sampler is a diluter optimised for fine
More informationA novel technique of friction and material property measurement by tip test in cold forging
A novel technique of friction and material property measurement by tip test in cold forging Y T Im*, S H Kang, and J S Cheon Department of Mechanical Engineering, Korea Advanced Institute of Science and
More informationEffects of the Leakage Flow Tangential Velocity in Shrouded Axial Compressor Cascades *
TSINGHUA SCIENCE AND TECHNOLOGY ISSNll1007-0214ll21/21llpp105-110 Volume 14, Number S2, December 2009 Effects of the Leakage Flow Tangential Velocity in Shrouded Axial Compressor Cascades * KIM Jinwook
More informationMETHYL ETHYL KETONE PEROXIDE 3508
METHYL ETHYL KETONE PEROXIDE 3508 C 8 H 16 O 4 MW: 176.21 CAS: 1338-23-4 RTECS: EL9450000; 21837 METHOD: 3508, Issue 2 EVALUATION: PARTIAL Issue 1: 15 August 1987 Issue 2: 15 August 1994 OSHA : NIOSH:
More informationThermo-Fluid Performance of a Vapor- Chamber Finned Heat Sink
The Egyptian International Journal of Engineering Sciences and Technology Vol. 20 (July 2016) 10 24 http://www.eijest.zu.edu.eg Thermo-Fluid Performance of a Vapor- Chamber Finned Heat Sink Saeed A.A.
More information5. SPRAY/WALL IMPINGEMENT
5. SPRAY/WALL IMPINGEMENT 5.1 Wall Interaction Regimes Wachters and Westerling (1966), Akao et al. (1980), Senda et al. (1994) and Nagaoka et al. (1994) describe in detail the phenomena observed when drops
More informationSTUDY OF DESIGN OF CYCLONE SEPARATOR UNDER COLLECTION EFFICIENCY AND AIR DENSITY EFFECT
STUDY OF DESIGN OF CYCLONE SEPARATOR UNDER COLLECTION EFFICIENCY AND AIR DENSITY EFFECT Radhe Shyam Verma 1, Prakash Kumar Sen 2, Shailendra Kumar Bohidar 3 1 Student, Mechanical Engineering, Kirodimal
More informationPolymer Reaction Engineering
Polymer Reaction Engineering Polymerization Techniques Bulk Solution Suspension Emulsion Interfacial Polymerization Solid-State Gas-Phase Plasma Polymerization in Supercritical Fluids Bulk Polymerization
More informationExperiment 2 Solvent-free Aldol Condensation between 3,4-dimethoxybenzaldehyde and 1-indanone
Experiment 2 Solvent-free Aldol Condensation between 3,4-dimethoxybenzaldehyde and 1-indanone Chemical Concepts Carbonyl chemistry, base catalyzed aldol reaction, melting point, recrystallization Green
More informationDETERMINATIONS OF THE POLLUTION LEVEL OF THE ENVIRONMENT WITH HEAVY METALS
7 th INTERNATIONAL MULTIDISCIPLINARY CONFERENCE Baia Mare, Romania, May 17-18, 2007 ISSN-1224-3264 DETERMINATIONS OF THE POLLUTION LEVEL OF THE ENVIRONMENT WITH HEAVY METALS Mariana Dobra, Vasile Viman,
More informationDEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD
Chapter 4 DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD 4.1 INTRODUCTION Sputter deposition process is another old technique being used in modern semiconductor industries. Sputtering
More informationEvaluation of the Effect of Relative Humidity of Air on the Coefficients of Critical Flow Venturi Nozzles
Evaluation of the Effect of Relative Humidity of Air on the Coefficients of Critical Flow Venturi Nozzles K. Chahine and M. Ballico National Measurement Institute, Australia P O Box 264, Lindfield, NSW
More informationIn this place, the following terms or expressions are used with the meaning indicated:
B05D PROCESSES FOR APPLYING LIQUIDS OR OTHER FLUENT MATERIALS TO SURFACES, IN GENERAL (apparatus for applying liquids or other fluent materials to surfaces B05B, B05C; {coating of foodstuffs A23P 20/17,
More information