SafeN130 Movable Apparatus for Radioactive Noble Gases Removing
|
|
- Corey Greer
- 5 years ago
- Views:
Transcription
1 SafeN130 Movable Apparatus for Radioactive Noble Gases Removing
2 Introduction The movable apparatus for removing radioactive noble gases which is developed from DS SCIENCE INC (Model SafeN130), is a prevention device for the worker's radioactive exposure and the environment pollution by removing the existing radioactive noble gases in the inside air of high pollution area(s/g, PZR etc.) in the building of nuclear power plant during OverHaul(O/H) period. Features Removing the noble gases up to 99% (Xe, Kr, Ar etc.) The bigger removing capacity than the existing removing capacity. about 28times(2.5CFM 70CFM) Movable compact size Easy to use (Convenient Assemble and Disassemble) Moving by 2 person. When the temperature is 4 ~90, the humidity is 10%~99% and the inhaling rate is Developed by Original Korea technology 0.05m 3 /min~10m 3 /min of the inhaling air, the maximum removing rate of this device is following, the decontamination factor (DF, the valuation of output value from input) is in less then 10E+04±100 purification ability, it can impound and remove up to 99% until 100Ci radioactive capacity of all gases. Patent application : Korea, China, UAE 2 3
3 1st moisture removing device inside CO 2 removing trap Noble gases removing trap Blower inside Movable supplying device for LN 2 2nd moisture removing trap Data Loger LN 2 Storage box Pressure dispersion device 4 5
4 Test result The analysis test at the former section of the first noble gases removing device - Confirming supplying the Xenon gases in to the trap by supplying variety concentration Xenon(Xe) (680ppm, 455ppm, 240ppm, 87ppm) The analysis test at the rear section of the second noble gases removing trap - Confirming detecting Xenon(Xe) in the gas which is passing first and second noble gases removing trap. As blow table, Xenon(Xe) is not detected. (Total test period : 22hours) The test result, confirming that Xenon gas is absorbed by noble gas removing device and after increasing temperature, the gas is exhausted. (We can confirm the noble gas device absorb the Xenon(Xe)) SafeN130 Specifications Ⅰ. Radioactive noble gases removing device Ⅱ. Supplement device 1. 1st moisture removing device Dimension (mm) : 500(W) x 840(H) x 800(D) Refrigerant : R-22 Weight : About 50kg Power : 220V, 60Hz, 11.5A Condensation exhausting method : Continually natural draining 2. Main instrument 1) 2nd moisture removing trap and CO 2 removing trap Dimension(mm) : 800(W) x Ø165(R) Opening and shutting device : Manual handle Clamp Band : STS 304 Gasket : Silicon Temperature sensor for measuring exothermic temperature of absorbent : Pt-100 Measuring range for Temperature Humidity sensor : TH300(0~100% RH, -40 ~+180 ) Measuring range for CO 2 concentration sensor : 0~5,000ppm 2) Radioactive noble gases removing trap Dimension(mm) : 500(W) x 500(H) x Ø165(R) Opening and shutting device : Manual handle Clamp Band : STS 304 Gasket : Silicon Temperature sensor for measuring cooling temperature of absorbent : Pt-100(-200 ~+400 ) 3) LN 2 Storage box Dimension(mm) : 765(W) x 360(H) x 350(D) Inside capacity : 46 Liters Material of Inside/outside : A.B.S/PR Material of inside insulation : A kind of Polymer insulation 4) Total weight(full) : About 120kg 3. Blower Dimension(mm) : 500(W) x 840(H) x 800(D) Maximum flow rate : 1,560m 3 /hr RPM : 3,410rpm Maximum inhaling rate : 210m 3 /hr(3.5m 3 /min) Flow rate : 2m 3 /min Weight : About 40kg 1. Movable supplying device for liquid nitrogen Dimension(mm) : 643(H) x Ø480(R) Static evaporation rate : < 0.5 Liters/day Filling flow rate : Dripping up to 0.1 Liter/min, depending on application level Max. working pressure : < 300 mbar Storage container volume : 50 Liters Weight(empty) : 13kg Power consumption : avg. 10W, during pumping 50W Power : 115/230V AC with supplied power supply or 12V AC/DC Signal : RS232 for on/off Alarm : On 2. Pressure dispersion device 1) Main-body Dimension(mm) : 980(H) x Ø650(R), 6T Material : Stainless steel 304, etc. Weight : About 80kg Connection Port : Flexible metal horse connection port 24ea, Pressure gauge connection port, ball valve connection port(condensation drain) 2) Pressure gauge Accuracy : ±1.5% of full scale Scale range : 0~10Mpa(0~101.97kgf/cm 2 ) Operating temperature range : -20 ~+65 Connection part : Ball valve 1/2" (Welding on the top of pressure dispersion device) Composition for movable noble gases removing instrument 1st moisture removing device 2nd moisture removing device CO 2 removing trap Radioactive noble gas removing trap Air quick cooling device Liquid nitrogen tank Transportation device for moisture/co 2 removing trap Transportation device for radioactive noble gases removing trap Pressure dispersion device Temperature/Humidity measuring sensor CO 2 measuring sensor Data loger Movable auto supplying device for liquid nitrogen Computer system Manual 3ea 1set OPTIONS KIT(1 DAY: needed 3ea. /8hrs) - 2nd moisture removing trap - CO 2 removing trap - Radioactive noble gases removing trap 4ea 6 7
5 SafeN130 Movable Apparatus for Radioactive Noble Gases Removing DS SCIENCE INC., have developed movable radioactive noble gases removing instrument for efficient removing noble gases in the radioactive gases waste by analysis technology which is accumulated for many years. DS SCIENCE INC's movable radioactive noble gases removing instrument(safen130) is designed by compact size for moving it through small personnel, and it is designed to maximize the user convenience by easy assembling and disassembling without complex devices. Copyright DS SCIENCE INC. All rights reserved DS SCIENCE INC's advanced technology makes movable instrument for variety place from existing instrument for limitation place, and minimizes the consumption of lots of time and cost. Especially, it can protect the user's safety from pollution sources through exact data. 187, Gwangyeo-ro, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea An ISO 9001 : Certified Tel : Fax : Homepage : dss@dsscience.com
Fitting PS P - B - R2
INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable
More informationKjeltec 2300 Analyzer Unit
Kjeltec 2300 Analyzer Unit Automatic distillation and approved colorimetric titration for analysis of Kjeldahl nitrogen/protein, ammonium- nitrogen, TKN, Direct distillation (DD), volatile acids/ bases
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationSTATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016
APPLICATIONS Moisture monitoring of air or gas (SF6) Suitable for indoor or outdoor Industrial, medical or aerospace fields HIGHLIGHTS High voltage circuit breakers commonly used for distribution and transmission
More informationMagnetic Property Measurement System
Magnetic Property Measurement System Product Description Quantum Design's MPMS 3 represents the culmination of more than 3 years of development and design in the world of SQUID Magnetometry. Providing
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationVaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance
Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 Fast Response - Low Maintenance DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand- Held Dewpoint Meter DM70 offers accurate
More informationCALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05
Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point
More informationPressure. 1 Fitting PA R - N R2
INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides
More informationMetz Syn 10 Reaction Station
Metz Syn 10 Reaction Station For parallel chemistry, process development and reaction optimisation Simultaneously carry out 10 reactions, but each with a different temperature, from -30 C to +150 C...
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More informationCALYS 80P. Field pressure calibrator with high accuracy 0.01%
Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS
More informationSolenoid valves Type EVUL
Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.
More informationMicroscopy Cryostat System
OF AMERICA, INC. Microscopy Cryostat System RC102-CFM Microscopy Cryostat offers fast cooldown, high efficiency, lowest thermal drift, excellent temperature stability and ultra low vibration Optical cryostat
More informationCoflore Agitated Cell Reactor
Coflore Agitated Cell Reactor Coflore ACR The Coflore ACR is a lab flow reactor developed by AM Technology for studying chemistry in flow and developing scalable continuous processes. Its flexible design
More informationHigh-Pressure Volumetric Analyzer
High-Pressure Volumetric Analyzer High-Pressure Volumetric Analysis HPVA II Benefits Dual free-space measurement for accurate isotherm data Free space can be measured or entered Correction for non-ideality
More informationNoble Gas Control Room Accident Filtration System for Severe Accident Conditions (N-CRAFT)
E-Journal of Advanced Maintenance Vol.7-1 (2015) 34-42 Japan Society of Maintenology Noble Gas Control Room Accident Filtration System for Severe Accident Conditions (N-CRAFT) Axel HILL *1, Dr. Cristoph
More informationCONTINUOUS FINE DUST MEASURING SYSTEM
CONTINUOUS FINE DUST MEASURING SYSTEM PM 10 - PM 2,5 - PM 1 Particle count distribution DustMonit ENGINEERING SRL Via Paolo Diacono, 1-20133 Milano (MI) - ITALIA Tel ++39.02.26684830 - E-mail : info@conteng.it
More informationSLH-K Handheld Ultrasonic Flowmeter
SLH-K Handheld Ultrasonic Flowmeter Features High Accuracy measuring A c c u r a c y : ±1 %, l i n e a r i t y : 0. 5 %, r e p e a t a b i l i t y : 0. 2 % Wi d e m e a s u r i n g r a n g e Several types
More informationLABOTRON EXTRACTION & SYNTHESIS 2450 MHz
LABOTRON EXTRACTION & SYNTHESIS 2450 MHz The LABOTRON TM series is the generic name for a ground breaking range of integrated reactor and microwave transmission systems especially designed to carry out
More informationRS 1700/1900/2300/2900 High Density Reticle Stockers
RS 1700/1900/2300/2900 High Density Reticle Stockers CONTAMINATION CONTROL SOLUTIONS Benefits Secure reticle storage Tec-Cell technology Prolongs the reticle lifetime Fast reticle access time High storage
More informationAutomated Clinical Analyzer
Automated Clinical Analyzer Improved ease of operation and better test efficiency, and provides the optimal solution for routine operations, STAT operation and a broad range of clinical analysis requirements.
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More information473 Dew Point Hygrometer
gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator
More informationManual Dew point scanner PCE-DPT 1
PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA Tel: 410-387-7703 Fax: 410-387-7714 info@pce-americas.com www.pce-instruments.com/us www.industrial-needs.com PCE Instruments UK Ltd. Units
More informationPeltier Application Note
Peltier Application Note Early 19th century scientists, Thomas Seebeck and Jean Peltier, first discovered the phenomena that are the basis for today s thermoelectric industry. Seebeck found that if you
More informationUDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS
LABSOLUTIONS UDK Distillation Units Series A Full Range of Solutions for Kjeldahl Distillation ABCD The distillation unit is used to perform nitrogen and protein content analysis according to the Kjeldahl
More informationSolenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil
Data sheet Solenoid valve s CSV 2 - CSV 22 (NC) and solenoid coil CSV is a direct or servo-operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. CSV valves are for
More informationRS-C Flexible Reticle Stocker
RS-C Flexible Reticle Stocker CONTAMINATION CONTROL SOLUTIONS Benefits Secure reticle storage Tec-Cell technology Prolongs the reticle lifetime Fast reticle access time Full Flexibility The RS-C is a fully
More informationVacuum gas dynamics investigation and experimental results on the TRASCO-ADS Windowless Interface
Vacuum gas dynamics investigation and experimental results on the TRASCO-ADS Windowless Interface P. Michelato, E. Bari, E. Cavaliere, L. Monaco, D. Sertore; INFN Milano - LASA - Italy A. Bonucci, R. Giannantonio,
More informationDM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability
DM70 Hand-held Dewpoint Meter Truly Fast Response - Superior Long-term Stability DM70 - When Dry Air Is Important The Vaisala DM70 Hand-held Dewpoint Meter offers stable and fast measurement for industrial
More informationdata sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code
DONATELLO FAST Automatic floor closed cycle tissue processor for histological specimens Automatic tissue processor for histological specimens DONATELLO FAST code PRO0 RI General characteristics DONATELLO
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More informationBOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION
BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER Technical Description Version 2 BGRIMM AUTOMATION, South 4th Ring Road West, Beijing, China TEL: +86(10)59069762 Fax: +86(10)68360101 Contents BGRIMM AUTOMATION
More informationQDTL. Liquid Mass Transfer and Diffusion Coefficient Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console
Engineering and Technical Teaching Equipment Liquid Mass Transfer and Diffusion Coefficient Unit QDTL Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION ISO 9001: Quality Management (for Design,
More informationCOPLEY S C I E N T I F I C. A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for:
A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for: generating monodisperse aerosol by mobility classification with automatic concentration detection
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationVacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular
Vacuum Technology Vacuum Pumps Two general classes exist: Gas transfer physical removal of matter Mechanical, diffusion, turbomolecular Adsorption entrapment of matter Cryo, sublimation, ion Mechanical
More informationHELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer
ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer Static Vacuum HELIX MC Plus Dynamic range Multi collection High mass resolution Based on more than
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationCALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%
ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX
More informationLANCOM200 PORTABLE ACID DEWPOINT TEMPERATURE MONITORING. Acid Dewpoint SO3 H2 SO4 QUALITY CUSTOMER SOLUTIONS
PORTABLE ACID DEWPOINT TEMPERATURE MONITORING i Acid Dewpoint SO3 H2 SO4 QUALITY CUSTOMER SOLUTIONS AMETEK LAND HAS BEEN MANUFACTURING PRECISION MEASURING EQUIPMENT SINCE 1947. WE ARE SPECIALISTS IN NON-CONTACT
More informationIBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationIts modular concept allows to build up a ball valve for any degree of automation and any kind of application
Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With
More informationThe Vacuum Case for KATRIN
The Vacuum Case for KATRIN Institute of Nuclear Physics, Forschungszentrum Karlsruhe,Germany, for the KATRIN Collaboration Lutz.Bornschein@ik.fzk.de The vacuum requirements of the KATRIN experiment have
More informationIBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More information507F. Multi-Port Sanitary Ball Valve. Full Port ISO 5211 Mounting Pad. For Automated & Manual Service. Pharmaceutical. Bio-Technology.
507F Multi- Sanitary Ball Valve Full ISO 5 Mounting Pad For Automated & Manual Service Pharmaceutical Bio-Technology Cosmetic Food & Beverage The 507F Series //5-Way Sanitary Ball Valve The 507F is a true
More informationBERMAD Irrigation. BIC2000 Weather Station SYSTEM GUIDE VERSIONS : BIC ; PC 4.90
BIC2000 Weather Station SYSTEM GUIDE VERSIONS : BIC2000 3.92; PC 4.90 CONTENTS 1. SYSTEM OVERVIEW 3 2. WEATHER STATION SETUP 4 2.1 ISS AND CONSOLE SETUP 4 2. RF RTU SYSTEM SETUP 5 2.2 BIC2000 WEATHER STATION
More informationPRODUCT DATA SHEET. Eagle Eye Outdoor LED Module 3000K. RoHS Compliant. CUSTOMER :. DATE : REV : Rev. 1.0.
CUSTOMER :. DATE : 213. 3. 29. REV : Rev. 1.. PRODUCT DATA SHEET Eagle Eye Outdoor LED Module 3K MODEL NAME : LLDMWW-15K21A (Type II Lens - H:16 V:7 ) LLDMWW-15K22A (Type III Lens - H:135 V:6 ) LLDMWW-15K23A
More information405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook
Reference Manual 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com Reference Manual 405 and 1595 405 Compact Orifice Series and 1595 Conditioning
More informationPRODUCT DATA SHEET. Eagle Eye Outdoor LED Module 5700K. RoHS Compliant. CUSTOMER :. DATE : REV : Rev. 2.0.
CUSTOMER :. DATE : 213. 4. 23. REV : Rev. 2.. PRODUCT DATA SHEET Eagle Eye Outdoor LED Module 57K MODEL NAME : LLDMWW-15K71A (Type II Lens - H:16 V:7 ) LLDMWW-15K72A (Type III Lens - H:135 V:6 ) LLDMWW-15K73A
More informationAP1000 European 15. Accident Analyses Design Control Document
15.7 Radioactive Release from a Subsystem or Component This group of events includes the following: Gas waste management system leak or failure Liquid waste management system leak or failure (atmospheric
More informationTETRIS W FC NG kw
40 640 kw General description TETRIS W FC/NG is a free cooling chiller for indoor installation that integrates uncoupling exchanger, 3-way modulating valve, inverter-controlled pump on the source side
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph
ABB MEASUREMENT & ANALYTICS DATA SHEET PGC5000 Temperature programmed gas chromatograph 2 P G C 5 0 0 0 T E M P E R AT U R E P R O G R A M M E D D S/ P G C 5 0 0 0 T P - E N Measurement & Analytics The
More informationIon Pump Applications
Gamma Vacuum Gamma Vacuum designs, manufactures, and services ion pumps, titanium sublimation pumps, and their controls. We have grown to be an industry leading ion pump supplier through superior quality,
More information405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook
405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book NOTICE Read
More informationMARINELLI BEAKERS CATALOG
GA-MA & ASSOCIATES, INC. Specialty Products for the Radiochemistry Laboratory MARINELLI BEAKERS CATALOG Snap-on Lid Design Gas Marinelli Beaker Threaded Lid Design Tel: 352.687-8840 404 Cypress Road Fax:
More informationC80. Calvet Calorimeter From ambient to 300 C. A trademark of KEP Technologies group
C80 Calvet Calorimeter From ambient to 300 C A trademark of KEP Technologies group C80 SENSOR The C80 Calorimeter is one of the most powerful, yet flexible calorimeters available. The high precision Calvet
More informationPurification of N 2 and Ar. Hardy Simgen, MPIK Heidelberg
Purification of N 2 and Ar Hardy Simgen, MPIK Heidelberg 1 Outline Requirements Gas purification by adsorption N 2 purification Ar purification Techniques for analysis Summary Page 2 Production N 2, Ar
More information4 Way Reversing Valve
STANDARD 4 Way Reversing Valve SHF series four-way reversing valves are applicable for heat pump systems such as central, unitary and room air conditioners to realize switching between cooling mode and
More informationThermostatic expansion valves TUA/TUAE
MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves A/AE www.danfoss.com Thermostatic expansion valves, type A/AE Contents Page Introduction... Features... Standard range...
More informationNuclear Data for Emergency Preparedness of Nuclear Power Plants Evaluation of Radioactivity Inventory in PWR using JENDL 3.3
Nuclear Data for Emergency Preparedness of Nuclear Power Plants Evaluation of Radioactivity Inventory in PWR using JENDL 3.3 Yoshitaka Yoshida, Itsuro Kimura Institute of Nuclear Technology, Institute
More informationNEXTorr HV 100 HIGHLIGHTS
NEXTorr HV 100 HIGHLIGHTS General Features High pumping speed for all active gases Pumping speed for noble gases and methane High sorption capacity and increased lifetime Constant pumping speed in HV and
More informationZHEJIANG FOTECH INTERNATIONAL CO., LTD.
Company Profile Zhejiang Fotech International Co., Ltd is a leading manufacturer and supplier of Refrigerant Gases, Fluor Polymer and Fluor Rubber. Products that are inventoried include:r22, R32, R134A,
More informationcobas e 411 analyzer Confidence in every result.
17591_Brochure.qxd 11/1/06 10:46 AM Page 2 The cobas e 411 analyzer offers... Accurate Results ECL technology delivers excellent low-end sensitivity and broad dynamic ranges Quality Results Assay-specific
More informationEND4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY*
ENVIRONMENTALLY SOUND REFRIGERANT VERTICAL EVAPORATOR COILS ALL N COIL MODELS 1½ thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum fin N coil with latest high tech fin
More informationPRODUCT SPECIFICATIONS
FEATURES AND BENEFITS* Up to 14 year DC life 56V DC working voltage Resistive cell balancing Overvoltage outputs High power density 4U, half-rack package UL registered TYPICAL APPLICATIONS UPS systems
More informationSample and Bleed Valves
Pure-Flo Sample and Bleed Valves www.ittpureflo.com Application The Pure-Flo product line of Sample and Bleed Valves provides compact and economical means to extract process samples and bleed off excess
More informationENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY*
ENVIRONMENTALLY SOUND REFRIGERANT ENH4X Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS 2 thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum
More informationCTC 155 / 350 / 660 Dry-block calibrator
CTC 155 / 350 / 660 Dry-block calibrator Wide temperature range: CTC-155: -25 to 155 C CTC-350: 28 to 350 C CTC-660: 28 to 660 C Fast calibration External reference sensor External sensor control Easy
More informationProduct Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU
CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow Product Data CAPVU A06002 The CAPVU evaporator coils incorporate proven standards for reliable system operation and performance throughout the
More information10-year industry best core warranty. 2-year warranty on balance of unit.
MODEL FEATURES MERV-8 filters Fully insulated case Large cores for high efficiency No condensate pan or drain required AHRI Certified Rainhood included Access door for easy maintenance and Cleaning Integral
More informationThe first address for Titration. TITRONIC 300 and TitroLine 5000
The first address for Titration TITRONIC 300 and TitroLine 5000 Selection table titration piston burettes TITRONIC and automatic titrators TitroLine The most important features of titrators TitroLine and
More informationChilled Mirror Hygrometry
Chilled Mirror Hygrometry Precision instruments for critical measurement and control applications Chilled Mirror Hygrometry Wherever precise, fundamental measurements are required in your laboratory or
More informationSuperfluid helium and cryogenic noble gases as stopping media for ion catchers Purushothaman, Sivaji
University of Groningen Superfluid helium and cryogenic noble gases as stopping media for ion catchers Purushothaman, Sivaji IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's
More informationLatest generation testo air velocity & IAQ probes with cable handle. Instruction manual
Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of
More informationea980r Digital Anemometer User Manual
ea980r Digital Anemometer User Manual 1. Overview Thank you for purchasing the ennologic ea980r anemometer, a high quality instrument which measures 8 parameters: Wind Speed (mph, m/s, ft/min, knots, km/h)
More informationReal-Time Detection: From Gisclard et al.: A Simple Device for Air Analysis. AIHA Quarterly, 14(1):23-25 (1953)
Real-Time Detection: 1953 From Gisclard et al.: A Simple Device for Air Analysis. AIHA Quarterly, 14(1):23-25 (1953) Sampling Gases and Vapors Gas: A state of matter characterized by very low density and
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationPTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30
eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize
More informationHiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis
Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis vacuum analysis surface science gas analysis plasma diagnostics CATLAB overview The Hiden CATLAB is a catalyst characterisation
More informationThe Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:
The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering
More informationICONE DRAFT - EVALUATION OF THE CONSERVATISM OF NPP SAFETY ANALYSIS DOSE CALCULATIONS AS TYPICAL FOR LICENSING PURPOSES
Proceedings of the 18th International Conference on Nuclear Engineering ICONE18 May 17-21, 21, Xi'an, China ICONE18-29465 DRAFT - EVALUATION OF THE CONSERVATISM OF NPP SAFETY ANALYSIS DOSE CALCULATIONS
More informationARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision
ARGUS VI Static Vacuum Mass Spectrometer Static Vacuum ARGUS VI Multicollection Low Volume Precision Based on more than 20 years of experience in noble gas mass spectrometry instrumentation, we have developed
More informationDBS315 1-phase SIDE CHANNEL BLOWERS
DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high
More informationProduct Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow
CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow Product Data CN(P,R)VP CN(P,R)VT (Transition) A06008 A06007 This vertical design N -coil is a furnace
More informationH E L P I N G C H E M I S T S. UltraCLAVE. The Next Generation Microwave Digestion System
H E L P I N G C H E M I S T S UltraCLAVE The Next Generation Microwave Digestion System UltraCLAVE The Next Generation Microwave Digestion System Improving upon an established technology is always a challenge.
More informationEstimation of accidental environmental release based on containment measurements
Estimation of accidental environmental release based on containment measurements Péter Szántó, Sándor Deme, Edit Láng, Istvan Németh, Tamás Pázmándi Hungarian Academy of Sciences Centre for Energy Research,
More information4.1. Physics Module Form 4 Chapter 4 - Heat GCKL UNDERSTANDING THERMAL EQUILIBRIUM. What is thermal equilibrium?
Physics Module Form 4 Chapter 4 - Heat GCKL 2010 4.1 4 UNDERSTANDING THERMAL EQUILIBRIUM What is thermal equilibrium? 1. (, Temperature ) is a form of energy that flows from a hot body to a cold body.
More informationSpare parts list UC-S
Spare parts list UC-S Contents Water inlet and tank heating Water softener Water drain, Mediamat Cyclo Circulating pump Wash + rinse; bottom Wash + rinse; top Boiler Dosage Panelling Cover plate, electrical
More information405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook
405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 and 1595 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test
More informationDewpoint Meter Data Sheet / Instructions
Paint Test Equipment Dewpoint Meter Data Sheet / Instructions Dewpoint Meter Information ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment
More informationHiPace 1200, with TC 1200, DN 200 CF-F
HiPace 1200, with TC 1200, DN 200 CF-F HiPace 1200, with TC 1200, DN 200 CF-F Similar Image Powerful turbopump with a pumping speed of up to 1250 l/s for N 2 DN 200 CF-F flange for demanding UHV applications
More informationOrganic Polymer Feeding
Organic Polymer A successful Nalco polymer program requires the appropriate equipment to efficiently make up and feed the polymer. The feed equipment selected for a certain application depends on the polymer
More information473-SHX Dew Point Mirror
Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable
More informationSAFETY TRAINING LEAFLET 08 ACETYLENE, CALCIUM CARBIDE, LIME SLUDGE AND PURIFYING MATERIALS
SAFETY TRAINING LEAFLET 08 ACETYLENE, CALCIUM CARBIDE, LIME SLUDGE AND PURIFYING MATERIALS Doc 23.08/18 EUROPEAN INDUSTRIAL GASES ASSOCIATION AISBL AVENUE DES ARTS 3-5 B 1210 BRUSSELS Tel: +32 2 217 70
More information2.0 KEY EQUATIONS. Evaporator Net Refrigeration Effect. Compressor Work. Net Condenser Effect
2.0 KEY EQUATIONS Evaporator Net Refrigeration Effect Q net refrigeration effect [] = (H 1 H 4 ) lb (Refrig Flow Rate) (60) min lb min hr H 1 = leaving evaporator enthalpy lb ; H 4 = entering evaporator
More information