GP-B Telescope Determine Metering Tube Length P0364 Rev -

Similar documents
GP-B Telescope Determine Reticle Plate Pattern Position P0445 Rev -

GP-B Telescope Measurement of Telescope Transmission P0450 Rev -

STANFORD UNIVERSITY. Bonding Telescope to Quartz Block Readiness Review Completion Certificate. P0259 Rev. May 19, 1998 Updted February 12, 1999

OPERATIONS SUPPLEMENT FOR THE COMPARISON AUTOCOLLIMATOR, D600

NEW STANDARD SEXTANT OF THE U. S. NAVY

saxon Instruction Manual saxon Grandeur Brass Telescope High quality optics

Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2

x Builders Level Service Manual

Galileo Telescope Solar Viewer Joseph Hora, Elizabeth Hora 2017/09/18

RECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler

SCHIEBER TELESCOPES. Unique, High-Quality Telescopes

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

Physics 476LW Advanced Physics Laboratory Michelson Interferometer

4. Dispersion. The index of refraction of the prism at the input wavelength can be calculated using

Coma Correction. Diagram. Introduction

HT600 Dat e Code: 2 - HT MW Purchase Date: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE. All Rights Reserved

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere

Snow Blade Operator s/assembly Instructions

Assembly Manual for the Brevard Astronomical Society 16 inch F4.5 Dobsonian Telescope Brevard Astronomical Society P.O. Box 1084 Cocoa, FL 32922

Ph 3455/MSE 3255 Experiment 2: Atomic Spectra

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

Ballistic pendulum Operating Instructions Fig. 1: Ballistic pendulum SAFETY PRECAUTIONS

product manual H-3220A Benkelman Beam

4. Dispersion. The index of refraction of the prism at the input wavelength can be calculated using

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

RP-100 TELESCOPE Instruction Manual

LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY

Surveying Prof. Bharat Lohani Indian Institute of Technology, Kanpur. Module 5 Lecture 1

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Collimation with a Takahashi collimating scope

Quick Start Guide. The ieq45 GoTo German Equatorial Mount # 8000C

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

THE LOSMANDY G-11 MOUNT

THE HAVERFORD UNIVERSITY S STRAWBRIDGE OBSERVATORY S OF THE 16 MEADE. A quick guide to using the 16 Meade Schmidt-Cassegrain Telescope

Automatic Level NP-732

Important Instructions

Dual Red or Green Electronic Dot Sight Instruction Manual

SIR C.R.REDDY COLLEGE OF ENGINEERING ELURU

Telescope. 1. Read these instructions carefully and familiarise yourself with the procedure before assembling the unit.

HORIZONTAL SETTING DEVICE

Miniball Flexible Frame

10 - Celestron Telescope II: Operation

ITTC Recommended Procedures and Guidelines

Collimation Instructions Learn how to accurately collimate the optics in your telescope.

Electron Microscopy Sciences INSTRUCTION MANUAL. Stereo Microscopes Non-illuminated Stands

EE 1/3.5х14 U EE 1/3.5х14 U

Kelly Morse Illinois Department of Transportation

INTRODUCTION TO ENGINEERING SURVEYING (CE 1305)

HV CAPACITOR SCREENING PROCEDURE FOR THE GYROSCOPE SUSPENSION SYSTEM (GSS) HV AMP/BRIDGE (HVA) BOARD. GP-B Procedure P0688 Rev -

ZFK 4 X 25. Description and Utilization Instructions

HERSCHEL/UVCI ALIGNMENT PLAN

Appendix 2: Disassembling and Assembling the Telescopes and the Celestron Equatorial Mounts

取扱説明書 /INSTRUCTION MANUAL 自動レベル /AUTOMATIC LEVEL AT-B2/B3/B4 FC10386-A012-02

Library Loaner Telescope Program

Polar Alignment of LX200R and Ultra Wedge For The Southern Hemisphere by Chris James

ER2 Short-head Electric Chain Hoist

Uniform Circular Motion

RP-200 TELESCOPE Instruction Manual

10-10 DIIAUS. Precision Reloading Scale

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 FRAUNHOFER DIFFRACTION

THE DIFFRACTION GRATING SPECTROMETER

Practical 1P4 Energy Levels and Band Gaps

Leveling. 3.1 Definitions

Electric Field Mapping

Read the following BEFORE getting started:

Galileoscope Assembly Instructions

EPOCSELFIR LACITCATiX5T TECHNICAL MANUAL

Practical 1P4 Energy Levels and Band Gaps

Atomic and nuclear physics

Measurement devices. Kalevi Aaltonen, Aalto University

CAUTION! NEVER ATTEMPT TO LOOK AT THE SUN WITH UNLESS YOU HAVE A FULL-APERTURE SOLAR FILTER (NOT INCLUDED WITH

BD-04a: Check Machine Geometry and Lost Motion

DISCONTINUED PRECISION MEASURING FOWLER CALIPERS 1 - VERNIER CALIPERS 4 - ELECTRONIC CALIPERS

Trial run of SWIFT instrument mounting onto PALAO. Version 1.1

Instruction Manual. Made in Japan

Spotting Scope Instruction Manual

P4Xi TACTICAL Riflescope TECHNICAL MANUAL

The Selector Diffuse Reflectance Accessory User Manual

Electric Field Mapping

AXTRUSION SUPPLEMENTARY MATERIALS. An approximate formula for estimating a bearing s stiffness is 1. P s A 2 h

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

Restoration of Bulle Clock Serial Number 24834

CPI SNOW PLOW KIT ASSEMBLY INSTRUCTIONS

General Physics I Lab (PHYS-2011) Experiment MECH-1: Projectile Motion

Altazimuth Mount. Altazimuth Mount

[ Extract from Astronomical Spectroscopy for Amateurs ] 18.0 Guiding, OAG and Beam splitters/ Flip mirrors Off Axis Guiders

Elastic Properties of Solids (One or two weights)

LEAPERS, INC. RED/GREEN DOTS

Uncertainty Analysis of Experimental Data and Dimensional Measurements

Operating Instructions Spectro-Goniometer Student. 1 Functional Elements. 2 Safety Precautions. Figure 1: Spectro-Goniometer Student

Must Read Before Installation TadPoleTM Safety and Warnings

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

INTEGRATION OF CAGING ASSEMBLIES INTO QB / PROBE

Current Balance Warm Up

CBRD30CP3 & BOWRD30CP INSTRUCTION MANUAL

Restoration of Eureka Clock Serial Number 4793

FAST CHECK THICKNESS GAGE

Electric Field Mapping Lab 2. Precautions

22X Builder s Transit Level Model No Instruction Manual

C A S S I N I. MODEL : C EQ3 900mm X 135mm COSMO BRANDS INC.

Transcription:

Stanford University W.W. Hansen Experimental Physics Laboratory Gravity Probe B Relativity Mission Stanford, California 94305-4085 GP-B Telescope Determine Metering Tube Length P0364 Rev - March 11, 1998 Prepared: Date Ken Bower, Telescope Assembly Approved: Date Jason Gwo, Telescope Assembly Approved: Date John Lipa, Telescope Manager Approved: Date John Turneaure, Hardware Manager Approved: Date Ben Taller, Quality Assurance

DETERMINE METERING TUBE LENGTH for SUGP-B dwg. #25091 follows Assemble Baseplate/Tertiary Mirror/Primary Mirror Assy. and Corrector Plate/Secondary Mirror Assy. (SUGP-B P0361) also use GP-B Telescope Image Divider Assembly (IDA) General Alignment and Bonding Procedures (SUGP-B P0282) for procedures concerning safety; personnel; work area requirements; fixture cleaning and acceptance; flight part inspection, handling, storage, and cleaning; redline authority; and sign-off and recording requirements. CAUTION: The flight parts and returning mirror used in this operation are heavy, delicate, and somewhat irreplaceable with multiple critical surfaces that can be easily damaged or contaminated by normal handling. Compliance with the above defined safe handling practices is critical. CAUTION: If at any time during this procedure flight hardware is not live monitored, verify that all flight hardware is seismically secured and protected against airborne contamination. WARNING: Some of the solvents, detergents, and/or bonding agents used in this procedure may be flammable, toxic, or reactive. Consult P0282 for information about specific chemicals. 1) Set-up fixtures. 1.1) Verify cleanliness of all fixtures and tools. Use special care to clean granite surface plate to remove any particulates. 1.2) Inspect the main rail for rust on critical surfaces. If necessary, lightly polish critical surfaces with a gauge block stone and reclean the rail. Place the rail (use normal care, this part is heavy!) on to the surface plate such that the slotted edge is toward you with the slot itself facing up. 1.3) Place the three guide pins in the slot on the rail. 1.4) Place the forward plate fixture on the rail over the middle guide pin. Adjust position and lock in place using the screws provided. 1.5) Place the baseplate fixture on the rail over the left guide pin. Attach the adjusting screw mechanism to it and the left end of the rail. 1.6) Place the knife edge fixture on the rail over the right guide pin. Attach the adjusting screw mechanism to it and the right end of the rail. 1.7) Adjust the three horizontal brass locator screws on the forward plate fixture such that the plane defined by their ends is approximately parallel to the fixture and perpendicular to the rail. Repeat for the baseplate fixture.

1.8) Adjust the two centering brass locator screws on the forward plate fixture such that the 7.25 diameter forward plate assembly will be approximately centered with respect to the fixture and rail when placed against the five brass contacts. Repeat for the baseplate fixture. 1.9) Place the two measurement transfer plates on the surface plate against the closest edge of the rail such that their polished surfaces face left and install the long adjusting rod between them. 1.10) Place the two measurement transfer plate clamps over the rail and into the slots on the plates. Tighten the locking screws on the clamps until the plates are still just able to move against the rail by hand. 1.11) Assemble any remaining parts onto the knife edge fixture (should be preassembled) and install the fiber optic into the fixture. Attach the other end of the fiber to a light source. 1.12) Verify cleanliness of all fixtures and nearby work area. 1.13) Place a small piece of Kapton tape over each brass locating screw which will contact flight or other glassy parts. Use care to prevent the entrapment of any particles or air bubbles under the tape. 1.14) Certification: Date/Time Signature Work Area Fixture Cleanliness Fixture Set-up Notes 2) Install and align flight parts. 2.1) Place the forward plate assembly (SUGP-B dwg. #25088) in the left side of the forward plate fixture with the secondary mirror facing left and the 12:00 o clock mark approximately up. Place the three spring clamps on to the forward plate such that the plate is secured and no part of the clamps obscures any part of the clear aperture. 2.2) Temporarily tighten the clamp on one of the alignment transfer plates. Place a D- 656 2.5 autocollimator to the left of the main rail such that its beam will reflect from both the polished surface of the plate and the surface of the forward plate. Use intermediate mirrors as required.

2.3) Carefully adjust any of the five brass locating screws as desired to improve alignment of the forward plate assembly with respect to the fixtures and verify that the forward plate and reflecting surface of the transfer plate are aligned within 30 arc-seconds. Ensure that the assembly is in solid contact with all five locator screws. 2.4) Place the autocollimator to the left of the main rail such that it s beam will pass through the 3:00 o clock position of the baseplate (viewed from the top). Align the return image of the autocollimator beam with the forward plate and lock the autocollimator in place. 2.5) Carefully install the large returning mirror in the right side of the forward plate fixture such that the hole in the center approximately aligns with the center of the forward plate. Place the three spring clamps on the returning mirror such that the mirror is secured. Move the knife edge fixture as required to complete this step. 2.6) Adjust the two locating screws on the bottom of the mirror and clock the mirror as required to center the hole in the mirror with respect to the forward plate. Ensure that the mirror is in solid contact with all five locator screws. 2.7) Using the autocollimator, verify that the mirror is parallel to the forward plate within one arc-second. If the mirror is not parallel, recheck the contact points and clamps and shim as required to generate parallelism. 2.8) Place the baseplate assembly (SUGP-B dwg. #25087) in the baseplate fixture with the primary mirror facing right and the 12:00 o clock mark approximately up. Place the three spring clamps on to the baseplate such that the assembly is secured. 2.9) Carefully adjust the two centering screws on the baseplate fixture such that the baseplate is centered with respect to the forward plate to within 0.02 (the shadow cast by the intersection of the baseplate and the autocollimator beam upon the forward plate makes a good reference for this). 2.10) Using the autocollimator as a reference, carefully adjust the three locator screws on the left of the baseplate fixture such that the bottom of the baseplate is perpendicular to the reference beam to within one arc-second. Verify that the assembly is in solid contact with all five locator screws. 2.11) Certification: Flight Part Handler Date/Time Signature Fixture Cleanliness Flight Part Cleanliness Alignment Verified

Notes 3) Establish correct spacing. 3.1) Using the adjusting screw mechanism, adjust the knife edge assembly such that the knife edge is 1.520+/-0.010 from the top (right surface) of the forward plate assembly and lock in place. 3.2) Turn on the light source. Flip the coarse view lens on the knife edge fixture to its on position behind the knife edge. Look through the coarse view lens and adjust the height of the knife edge such that the return image of the light is barely visible. Place a small c-clamp on the knife edge fixture to secure the height adjustment. Only tighten the clamp enough to still allow some future height adjustment. 3.3) Flip the coarse view lens away and hold the fine view lens by hand to view the returned image. This is a difficult step and will require some practice. 3.4) While monitoring the image, raise the knife edge slightly and observe the fashion in which the image becomes dark. Most likely the image will be occluded by the knife edge from top to bottom or bottom to top. If the image became uniformly dark over a very small height adjustment, then the knife edge is located in the Airy disk within the focal depth of the telescope (<0.030 ) which indicates that the baseplate is within 0.0005 (60:1 lever arm ratio) of the ideal location. 3.5) If the baseplate is not within the desired range, adjust the position of the baseplate fixture by several mils (about 1/2 turn of the adjusting screw) in any direction and repeat steps 3.3 and 3.4. Use care to ensure that the baseplate fixture remains in correct alignment with the guide pin and rail throughout all adjustments. This can also be verified by checking alignment with the autocollimator. 3.6) If the direction of occlusion reversed, the ideal location is between the two baseplate positions observed. If the direction of occlusion did not reverse, the ideal location is past the position which occluded the quickest. Iteratively adjust the position of the baseplate fixture until the ideal location is found. 3.7) Lock the baseplate fixture in place. Verify parallelism of all parts with the autocollimator. Verify correct spacing between the knife edge and forward plate. 3.8) Verify that the baseplate is still in the ideal location by repeating steps 3.3 and 3.4. 3.9) Certification: Flight Part Handler(s)

Date/Time Signature Fixture Cleanliness Flight Part Cleanliness Alignment Verified Notes 4) Measure spacing. 4.1) Primary measurement. 4.1.1) Verify the cleanliness of all fixtures and flight parts as required. 4.1.2) Install the dial indicator on to the measurement transfer post. Place the post on to the surface plate against the left surface of the right measurement transfer plate. 4.1.3) Adjust the dial indicator and right measurement transfer plate as required such that the dial indicator reads zero (+/- 0.0001 ) while the post is in five point contact with the surface and transfer plates and the dial indicator contact point is touching the top (right) surface of the forward plate. 4.1.4) Tighten the clamp to lock the right measurement transfer plate against the rail and repeat step 4.1.3. 4.1.5) Verify the cleanliness of all flight parts as required. 4.1.6) Place the measurement transfer post on to the surface plate against the left surface of the left measurement transfer plate. 4.1.7) Adjust the position of the left measurement transfer plate using the long adjusting rod such that the dial indicator reads zero (+/- 0.0001 ) while the post is in five point contact with the surface and transfer plates and the dial indicator contact point is touching the top (right) surface of the baseplate. 4.1.8) Tighten the clamp to lock the left measurement transfer plate against the rail and verify correct position established in step 4.1.7. 4.1.9) Place a long (6 + capacity) depth gauge (i.e. Starrett 445BZ-9RL) in the narrow groove of the left measurement transfer plate with the drive end flush against the polished face. 4.1.10) Build a stack of calibrated gauge blocks tall enough to span from the polished surface of the right measurement transfer plates to within the range of the depth micrometer. Lay the stack on its side on the surface plate against the polished surface of the right measurement transfer plate.

4.1.11) Keeping the head of the depth micrometer flush with the left plate, adjust its length until the end contacts the gauge block stack. Add the reading on the micrometer, the basic length of the micrometer, the sum of the gauge blocks used in the stack, and the negative value of the thickness of the forward plate (from inspection report or independent measurement). This sum is the required length of the metering tube. 4.1.12) Place the measurement transfer post against each transfer plate and verify that the dial indicator readings are still identical when brought into contact with each flight part surface. 4.1.13) Repeat step 4.1.10 using a different configuration of blocks (shuffle and/or substitute). 4.1.14) Repeat step 4.1.11 and compare sums. If the sums are different, repeat steps 4.1.1 through 4.1.13 as required until the variance of sums is at most less than 0.0005 and is preferably less than 0.0002. 4.1.15) Certification: Flight Part Handler(s) Date/Time Signature Fixture Cleanliness Flight Part Cleanliness Alignment Verified micrometer reading depth gauge length gauge block stack <forward plate>

Metering Tube length variance N/A Average Notes 4.2) Verification of measurement. 4.2.1) Protect the four contact surfaces of the length transfer rod with Kapton tape as in step 1.13. Verify the cleanliness of all fixtures as required. 4.2.2) Place the height gauge (Starrett model 259-24) on the granite surface plate and verify a correct reading (+/- 0.0005 ) by comparison to calibrated gauge blocks in both the 0-1 and 6-12 ranges. 4.2.3) Set the height gauge to the height determined in step 4.1.14. Place the custom adjustable length transfer rod on the surface plate underneath the gauge and adjust the rod as required such that the dial indicator reads zero (+/- 0.0001 ) when in contact with the bottom of the scriber. 4.2.4) Verify the cleanliness of flight parts as required. 4.2.5) Carefully place the rod between the baseplate and forward plate assemblies and ensure that all three legs of the rod are in solid contact with the baseplate. Depress the plunger of the dial indicator as required during installation to protect the surface of the forward plate. 4.2.6) Repeat step 4.2.5 at two or more other clocking locations between the two flight parts. 4.2.7) Compare the dial indicator readings of the measurements taken in steps 4.2.5 and 4.2.6. If the variance is greater than 0.0005, evaluate and repeat any steps 4.2.1 through 4.2.6 as required. 4.2.8) Compare the measurement taken in step 4.2.7 to that taken in step 4.1.14. If the variance is greater than 0.0015, evaluate and repeat any steps 3.1 through 4.2.7 as required. 4.3) Verification of conditions 4.3.1) Verify that no change in alignment or spacing has occurred by repeating steps 3.7 and 3.8. If changes have occurred, repeat any steps as required.

4.1.15) Certification: Flight Part Handler(s) Date/Time Signature Fixture Cleanliness Flight Part Cleanliness Height Gauge Verified Alignment Verified micrometer reading variance N/A Prior Average variance Notes 5) If the final measurement taken in step 4.1.14 complies with step 4.2.8, report that measurement to the telescope responsible engineer for application to the final metering tube (SUGP-B dwg. #25061) length. 6) Verify the cleanliness of all flight parts and return them to appropriate storage. Flight Part Handler(s) Date/Time Signature Flight Part Cleanliness Notes

Attachments: SUGP-B dwg. # s 25091, 25088, 25087, 25061; Fixture Set-up Sketch.