Shear at the interface between concrete cast

Similar documents
Design of a Rectangular CS for Bending

Creep and Shrinkage Calculation of a Rectangular Prestressed Concrete CS

Design of a Steel I-section for Bending and Shear

Design of a Steel I-section for Bending, Shear and Axial Force

Benchmark Example No. 12. Cantilever in Torsion

Benchmark Example No. 15. Flexural and Torsional Buckling

VERiFiCATiON MANUAL Design Code Benchmarks

Cylindrical Hole in an Infinite Mohr-Coulomb Medium

A Circular Cavity Embedded in a Full-Plane Under Impulse Pressure

Triaxial Consolidated Undrained (CU) Test

Einführung des EC2 in Belgien The introduction of EC2 in Belgium

Design of reinforced concrete sections according to EN and EN

Assignment 1 - actions

Bending and Shear in Beams

NAGY GYÖRGY Tamás Assoc. Prof, PhD

Thermal Analysis for Solid Structures

CRACK FORMATION AND CRACK PROPAGATION INTO THE COMPRESSION ZONE ON REINFORCED CONCRETE BEAM STRUCTURES

Computational limit state analysis of reinforced concrete structures

DESIGN OF DOWELS FOR SHEAR TRANSFER AT THE INTERFACE BETWEEN CONCRETE CAST AT DIFFERENT TIMES: A CASE STUDY

Concise Eurocode 2 25 February 2010

Design of AAC wall panel according to EN 12602

Depending on the application and the anchor type one of the following two concepts can be applied: Partial safety factor concept.

STEEL BUILDINGS IN EUROPE. Multi-Storey Steel Buildings Part 8: Description of member resistance calculator

Reinforced concrete structures II. 4.5 Column Design

O Dr Andrew Bond (Geocentrix)

10/14/2011. Types of Shear Failure. CASE 1: a v /d 6. a v. CASE 2: 2 a v /d 6. CASE 3: a v /d 2

Improving fire resistance of existing concrete slabs by concrete topping

Detailing. Lecture 9 16 th November Reinforced Concrete Detailing to Eurocode 2

STRESS FIELD MODELS FOR STRUCTURAL CONCRETE

NUMERICAL SIMULATIONS OF CORNERS IN RC FRAMES USING STRUT-AND-TIE METHOD AND CDP MODEL

Standardisation of UHPC in Germany

Practical Design to Eurocode 2. The webinar will start at 12.30

Department of Mechanics, Materials and Structures English courses Reinforced Concrete Structures Code: BMEEPSTK601. Lecture no. 6: SHEAR AND TORSION

Eurocode Training EN : Reinforced Concrete

Concrete subjected to combined mechanical and thermal loading: New experimental insight and micromechanical modeling

Verification Manual. of GEO5 Gravity Wall program. Written by: Ing. Veronika Vaněčková, Ph.D. Verze: 1.0-en Fine Ltd.

Seismic Design, Assessment & Retrofitting of Concrete Buildings. fctm. h w, 24d bw, 175mm 8d bl, 4. w 4 (4) 2 cl

Pre-stressed concrete = Pre-compression concrete Pre-compression stresses is applied at the place when tensile stress occur Concrete weak in tension

RELIABILITY ASSESSMENT OF EXISTING STRUCTURES

Eurocode 3: Design of steel structures. Part 1-6: Strength and Stability of Shell Structures National Annex

Concrete and Masonry Structures 1 Office hours

Tower Cranes & Foundations The Interface & CIRIA C654 Stuart Marchand C.Eng. FICE FIStructE Director Wentworth House Partnership

Chapter 12. Static Equilibrium and Elasticity

1 Input data. Profis Anchor Company: Specifier: Address: Phone I Fax: Page: Project: Sub-Project I Pos. No.

WP6 - Thought for Eurocodes Upgrade

Validation of the Advanced Calculation Model SAFIR Through DIN EN Procedure

1 Input data. Profis Anchor Company: Specifier: Address: Phone I Fax: Page: Project: Sub-Project I Pos. No.

Delhi Noida Bhopal Hyderabad Jaipur Lucknow Indore Pune Bhubaneswar Kolkata Patna Web: Ph:

SHEAR RESISTANCE BETWEEN CONCRETE-CONCRETE SURFACES

DESIGN OF STAIRCASE. Dr. Izni Syahrizal bin Ibrahim. Faculty of Civil Engineering Universiti Teknologi Malaysia

REINFORCED CONCRETE DESIGN 1. Design of Column (Examples and Tutorials)

Software Verification

CE5510 Advanced Structural Concrete Design - Design & Detailing of Openings in RC Flexural Members-


MS Excel Toolkit: Design of steel-concrete composite columns in accordance with EN

Chapter 8. Shear and Diagonal Tension

9-3. Structural response

EUROCODE EN SEISMIC DESIGN OF BRIDGES

Reinforced Concrete Structures

Code_Aster. Calculation algorithm of the densities of reinforcement

Finite Element Modelling with Plastic Hinges

DEFORMATION CAPACITY OF OLDER RC SHEAR WALLS: EXPERIMENTAL ASSESSMENT AND COMPARISON WITH EUROCODE 8 - PART 3 PROVISIONS

SPECIFIC VERIFICATION Chapter 5

4.2 Partial factor method based on the design value approach

MECHANICS OF MATERIALS. Prepared by Engr. John Paul Timola

RETAINING WALL ANALYSIS

RETAINING WALL ANALYSIS

STRUCTURE DESCRIPTION

Uncertainty modelling using software FReET

my!wind Ltd 5 kw wind turbine Static Stability Specification

Note on the moment capacity in a Bubble deck joint

FE analysis of steel-concrete composite structure with partial interactions

SeismoBuild Verification Report (KANEPE) For version 2018

RELIABILITY ASPECTS OF DESIGN OF COMBINED PILED-RAFT FOUNDATIONS (CPRF)

Software Verification

prepared checked approved Date: Date: Date: S. Fahrendholz/R.Geiger Dr.-Ing. Jürgen Bellmann Dr.-Ing.

Compression perpendicular to the grain

STRUCTURAL ANALYSIS CHAPTER 2. Introduction

Practical Design to Eurocode 2

English version Version Française Deutsche Fassung

English version Version Française Deutsche Fassung

A Simplified Method for the Design of Steel Beam-to-column Connections

VORONOI APPLIED ELEMENT METHOD FOR STRUCTURAL ANALYSIS: THEORY AND APPLICATION FOR LINEAR AND NON-LINEAR MATERIALS

PUNCHING SHEAR CALCULATIONS 1 ACI 318; ADAPT-PT

Tension zone applications, i.e., cable trays and strut, pipe supports, fire sprinklers Seismic and wind loading

6. Bending CHAPTER OBJECTIVES

SERVICEABILITY LIMIT STATE DESIGN

Verification of a Micropile Foundation

Job No. Sheet No. Rev. CONSULTING Engineering Calculation Sheet

Eurocode 7 from soil mechanics to rock mechanics. Luís Lamas, LNEC, Lisbon, Portugal Didier Virely, CEREMA, Toulouse, France

Analysis of the horizontal bearing capacity of a single pile

Chapter. Materials. 1.1 Notations Used in This Chapter

Strengthening of columns with FRP

General elastic beam with an elastic foundation

I certify that I have not given unauthorized aid nor have I received aid in the completion of this exam.

LIVING REINFORCED SOIL - AN ECOLOGICAL METHOD TO STABILISE SLOPES

Annex - R C Design Formulae and Data

Verification Examples

Hilti North America Installation Technical Manual Technical Data MI System Version

A through-bolt expansion wedge anchor with controlled torque, for use in cracked and non cracked concrete.

Transcription:

Benchmark Example No. 11 Shear at the interface between concrete cast SOFiSTiK 2018

VERiFiCATiON MANUAL DCE-EN11: Shear at the interface between concrete cast VERiFiCATiON MANUAL, Version 2018-7 Software Version: SOFiSTiK 2018 Copyright 2018 by SOFiSTiK AG, Oberschleissheim, Germany. SOFiSTiK AG HQ Oberschleissheim Office Nuremberg Bruckmannring 38 Burgschmietstr. 40 85764 Oberschleissheim 90419 Nuremberg Germany Germany T +49 (0)89 315878-0 T +49 (0)911 39901-0 F +49 (0)89 315878-23 F +49(0)911 397904 info@sofistik.com www.sofistik.com This manual is protected by copyright laws. No part of it may be translated, copied or reproduced, in any form or by any means, without written permission from SOFiSTiK AG. SOFiSTiK reserves the right to modify or to release new editions of this manual. The manual and the program have been thoroughly checked for errors. However, SOFiSTiK does not claim that either one is completely error free. Errors and omissions are corrected as soon as they are detected. The user of the program is solely responsible for the applications. We strongly encourage the user to test the correctness of all calculations at least by random sampling. Front Cover Project: New SOFiSTiK Office, Nuremberg Contractor: WOLFF & MLLER, Stuttgart Architecture: WABE-PLAN ARCHITEKTUR, Stuttgart Structural Engineer: Boll und Partner. Beratende Ingenieure VBI, Stuttgart MEP: GM Planen + Beraten, Griesheim Lead Architect: Gerhard P. Wirth gpwirtharchitekten, Nuremberg Vizualisation: Armin Dariz, BiMOTiON GmbH

Overview Design Code Family(s): DIN Design Code(s): DIN EN 1992-1-1 Module(s): AQB Input file(s): shear interface.dat 1 Problem Description The problem consists of a T-beam section, as shown in Fig. 1. The cs is designed for shear, the shear at the interface between concrete cast at different times is considered and the required reinforcement is determined. b eƒ ƒ h ƒ V Ed h d z s Shear section d 1 A s1 A s1 b Figure 1: Problem Description 2 Reference Solution This example is concerned with the shear design of T-sections, for the ultimate limit state. The content of this problem is covered by the following parts of DIN EN 1992-1-1:2004 [1]: Design stress-strain curves for concrete and reinforcement (Section 3.1.7, 3.2.3) Guidelines for shear design (Section 6.2) new concrete anchorage h 2 10d 45 α 90 α N Ed b 30 h 1 10d old concrete anchorage V Ed b Figure 2: Indented Construction Joint - Examples of Interfaces The design stress-strain diagram for reinforcing steel considered in this example, consists of an inclined top branch, as presented in Fig. 3 and as defined in DIN EN 1992-1-1:2004 [1] (Section 3.2.7). SOFiSTiK 2018 Benchmark No. 11 3

σ A ƒ tk,c ƒ yk ƒ yd = ƒ yk /γ s B A B Idealised Design ε Figure 3: Idealised and Design Stress-Strain Diagram for Reinforcing Steel 3 Model and Results The T-section, with properties as defined in Table 1, is to be designed for shear, with respect to DIN EN 1992-1-1:2004 (German National Annex) [1], [2]. The reference calculation steps [3] are presented in the next section and the results are given in Table 2. Table 1: Model Properties Material Properties Geometric Properties Loading C 20/25 h = 135.0 cm V z = 800 kn B 500A h ƒ = 29cm M y = 2250 knm d 1 = 7.0 cm b = 40 cm, b eƒ ƒ = 250 cm A s1 = 1.0 cm 2 z s = 95.56 cm Table 2: Results s [cm 2 /m] SOF. Ref. state 7.00 7.07 state only V 4.86 4.90 state V + M 4.99 4.99 4 Benchmark No. 11 SOFiSTiK 2018

4 Design Process 1 Design with respect to DIN EN 1992-1-1:2004 (NA) [1] [2]: 2 Material: Concrete: γ c = 1.50 Steel: γ s = 1.15 (NDP) 2.4.2.4: (1), Tab. 2.1DE: Partial factors for materials ƒ ck = 25 MP ƒ cd = cc ƒ ck /γ c = 0.85 25/1.5 = 14.17 MP Tab. 3.1: Strength for concrete 3.1.6: (1)P, Eq. (3.15): cc = 0.85 considering long term effects ƒ yk = 500 MP 3.2.2: (3)P: yield strength ƒ yk = 500 ƒ yd = ƒ yk /γ s = 500/1.15 = 434.78 MP MP 3.2.7: (2), Fig. 3.8 σ sd = 456.52 MP τ = T b = V S y b where S is the static moment of the separated area S = h b (z s h /2) = 0.18058 m 3 0.8 0.18058 τ = = 2.1669 MP 0.16667 0.4 0.8 0.18058 T = = 0.86676 MN/m = 866.76 kn/m 0.16667 T = 866.76 / 2 = 433.38 kn/m The shear section with a length of 0.4 m is split into two equal parts with b = 0.2 m State : Design Load: V Ed = T = 433.38 kn/m The associated design shear flow V Ed is: Ed = τ = 2.1669 MP V Rd,c = C Rd,c k (100 ρ 1 ƒ ck ) 1/3 + 0.12 σ cp b d (NDP) 6.2.2 (1): Eq. 6.2a: Design value for shear resistance V Rd,c for members Rd,c = C Rd,c k (100 ρ 1 ƒ ck ) 1/3 + 0.12 σ cp ρ 1 = A s b d = 0.0 Rd,c = 0.0 with a minimum of not requiring design shear reinforcement V Rd,c,mn = ν mn + 0.12 σ cp b d (NDP) 6.2.2 (1): Eq. 6.2b Rd,c,mn = ν mn + 0.12 σ cp 1/2 ν mn = (0.0375/γ c ) k 3/2 ƒck = 0.20833 MP (NDP) 6.2.2 (1): Eq. 6.3bDE 1 The tools used in the design process are based on steel stress-strain diagrams, as defined in [1] 3.2.7:(2), Fig. 3.8, which can be seen in Fig. 3. 2 The sections mentioned in the margins refer to DIN EN 1992-1-1:2004 (German National Annex) [1], [2], unless otherwise specified. SOFiSTiK 2018 Benchmark No. 11 5

Rd,c,mn = 0.20833 Rd,c = 0.20833 MP Ed > Rd,c shear reinforcement is required 6.2.5 (1): Eq. 6.23: The design shear stress at the interface should satisfy this (NDP) 6.2.5 (1): Eq. 6.25 Maximum shear stress Rd,m (NDP) 6.2.5 (1): ν = 0.70 for indented surface 6.2.5 (2): c, μ: factors depending on the roughness of the interface (NDP) 3.1.6 (2)P: Eq. 3.16 α ct = 0.85 3.1.2 (3): Tab. 3.1 - Strength for concrete: ƒ ctk;0.05 = 1.8 MP: ρ = s : area of reinforcement crossing interface / area of b joint Ed Rd Rd = c ƒ ctd + μ σ n + ρ ƒ yd (1.2 μ sin α + cos α) and Rd 0.5 ν ƒ cd Rd,m = 0.5 ν ƒ cd = 4.9585 MP c = 0.50 and μ = 0.9 for indented surface ƒ ctd = α ct ƒ ctk;0.05 / γ c ƒ ctd = 0.85 1.80 / 1.5 = 1.02 s Rd = 0.5 1.02 + 0 + 435 (1.2 0.9 1 + 0) 0.2 1.0 Rd = 0.51 + s 469.56 = 2.1669 0.2 s = 7.07 cm 2 /m State only shear force V: Design Load: From the calculated inner lever arms for the two states we get a ratio: z = 0.7664 z The associated design shear flow V Ed is: V Ed = 0.7664 433.38 = 332.15 kn/m and Ed = 332.15/0.2 = 1.66 MP Following the same calculation steps as for state we have: Rd,c = 0.20833 MP (as above) Ed > Rd,c shear reinforcement is required Ed Rd Rd = c ƒ ctd + μ σ n + ρ ƒ yd (1.2 μ sin α + cos α) s Rd = 0.5 1.02 + 0 + 435 (1.2 0.9 1 + 0) 0.2 1.0 Rd = 0.51 + s 469.56 = 1.66 0.2 s = 4.90 cm 2 /m 6 Benchmark No. 11 SOFiSTiK 2018

State shear force V and moment M: M Eds = 2250 knm μ Eds = M Eds b eƒ ƒ d 2 ƒ cd = 2250 10 3 2.5 1.28 2 14.17 = 0.03876 ω = 0.03971 and ξ = 0.9766 (interpolated) Tab. 9.2 [4]: ω Table for up to C50/60 without compression reinforcement A s1 = 1 σ sd (ω b d ƒ cd + N Ed ) = 39.44 cm 2 N Ed = 0 z = mx d c V, 30 mm; d 2 c V, z = mx {1160; 1190} = 1190 mm Design Load: (NDP) 6.2.3 (1): Inner lever arm z T = V / z = 800 / 1.19 = 672.268 kn/m The shear section with a length of 0.4 m is split into two equal parts with b = 0.2 m T = 672.268 / 2 = 336.134 kn/m V Ed = 336.134 kn/m and Ed = 336.134 / 0.2 = 1.68 MP Rd,c = C Rd,c k (100 ρ 1 ƒ ck ) 1/3 + 0.12 σ cp C Rd,c = 0.15/γ c = 0.1 200 k = 1 + d = 1 + 200 = 1.3953 < 2.0 1280 ρ 1 = A s b d = 39.44 = 0.007703 < 0.02 40 128 (NDP) 6.2.2 (1): C Rd,c = 0.15/γ c Rd,c = 0.1 1.3953 (100 0.007703 25) 1/3 + 0 Rd,c = 0.373229 MP Ed > Rd,c shear reinforcement is required Rd = c ƒ ctd + μ σ n + ρ ƒ yd (1.2 μ sin α + cos α) s Rd = 0.5 1.02 + 0 + 435 (1.2 0.9 1 + 0) 0.2 1.0 Rd = 0.51 + s 469.56 = 1.68 0.2 s = 4.99 cm 2 /m SOFiSTiK 2018 Benchmark No. 11 7

5 Conclusion This example shows the calculation of the required reinforcement for a T-section under shear at the interface between concrete cast at different times. It has been shown that the results are reproduced with excellent accuracy. Small deviations occur because AQUA calculates (by using FEM analysis) the shear stresses more accurate compared to the reference example. 6 Literature [1] DIN EN 1992-1-1/NA: Eurocode 2: Design of concrete structures, Part 1-1/NA: General rules and rules for buildings - German version EN 1992-1-1:2005 (D), Nationaler Anhang Deutschland - Stand Februar 2010. CEN. 2010. [2] F. Fingerloos, J. Hegger, and K. Zilch. DIN EN 1992-1-1 Bemessung und Konstruktion von Stahlbeton- und Spannbetontragwerken - Teil 1-1: Allgemeine Bemessungsregeln und Regeln für den Hochbau. BVPI, DBV, ISB, VBI. Ernst & Sohn, Beuth, 2012. [3] Beispiele zur Bemessung nach Eurocode 2 - Band 1: Hochbau. Ernst & Sohn. Deutschen Betonund Bautechnik-Verein E.V. 2011. [4] K. Holschemacher, T. Müller, and F. Lobisch. Bemessungshilfsmittel für Betonbauteile nach Eurocode 2 Bauingenieure. 3rd. Ernst & Sohn, 2012. 8 Benchmark No. 11 SOFiSTiK 2018