Similar documents
Modeling Ion Motion in a Miniaturized Ion Mobility Spectrometer

MODELING, DESIGN AND EXPERIMENTAL CARACHTERIZATION OF MICRO-ELECTRO ELECTRO-MECHANICAL- SYSTEMS FOR GAS- CHROMATOGRAPHIC APPLICATIONS

Owlstone Nanotech Inc

Développement de micro-préconcentrateurs pour l'analyse de traces de gaz et explosifs.

FAIMS Technology at a Glance

TANDEM DIFFERENTIAL MOBILITY SPECTROMETER:

RS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers

RESEARCH ON BENZENE VAPOR DETECTION USING POROUS SILICON

Training Coarse ECOPROBE 5 CHEMISTRY RS DYNAMICS

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

Mass Spectrometry. What is Mass Spectrometry?

Integrated measuring system for MEMS

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

The RAID-M had the highly sensitive TDI library in Library A of the instrument as shown in Table 1. Table 1: Highly sensitive TDI library in ppb.

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

CEE 772: Instrumental Methods in Environmental Analysis

Achim J. Lilienthal Erik Schaffernicht Achim J. Lilienthal. AASS, Örebro University

The Claviature of Gas Analysis

Introduction to GC/MS

Chromatography & instrumentation in Organic Chemistry

Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph

Chip-Scale Mass Spectrometers for Portable Gas Analyzers Luis Fernando Velásquez-García. A. I. Akinwande, K. Cheung, and L.-Y Chen.

Feasibility Study of using FAIMS to Detect Carbonyl Sulfide in Propane. Technical POC: Russell Parris Commercial POC: Billy Bolye

Institute for Electron Microscopy and Nanoanalysis Graz Centre for Electron Microscopy

2401 Gas (liquid) Chromatography


Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

Types of Analyzers: Quadrupole: mass filter -part1

APPENDIX A: Solvent effect

Secondary Ion Mass Spectroscopy (SIMS)

Time-of-Flight Flow Microsensor using Free-Standing Microfilaments

Ultra-sensitive High-speed Monitoring Technology for Trace-level Toxic Halogenated Hydrocarbon Compounds

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

Chemistry Instrumental Analysis Lecture 35. Chem 4631

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Griffin Analytical Technologies

The new 11-R (one part of the Mini WRAS) and GRIMM MINI-WRAS Andreas Jaksch. Symposium Stockholm Mai

Photoelectron Spectroscopy using High Order Harmonic Generation

Automotive Grade Silicon Capacitors for Under the Hood Applications

FINE PATTERN ETCHING OF SILICON USING SR-ASSISTED IONIZATION OF CF4 GAS

Monday March

HSG-IMIT Application AG

TANDEM MASS SPECTROSCOPY

MEMS Pirani type vacuum sensor with extended sensitivity range

CHARACTERIZATION AND FIELD EMISSION PROPERTIES OF FIELDS OF NANOTUBES

Questions, Myths and Misconceptions about Using Photoionization Detectors

FEATURE ARTICLE. The CS-100 Series High-precision Chemical Solution Monitor in the Semiconductor Cleaning Process. Takaaki Yada.

Correction of the electric resistivity distribution of Si wafers using selective neutron transmutation doping (SNTD) in MARIA nuclear research reactor

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Gas chromatography. Advantages of GC. Disadvantages of GC

Recent Results in the Development of Selected Ion Mobility Mass Spectrometry, SIM-MS, Technique

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Harris: Quantitative Chemical Analysis, Eight Edition

VOC measurements in ambient air using Selected Ion Flow Tube Mass Spectrometry-automation and calibration considerations

Physics of capnography

Mass Spectrometry in MCAL

Cluster measurements at CLOUD using a high resolution ion mobility spectrometermass spectrometer combination

MEMS INERTIAL POWER GENERATORS FOR BIOMEDICAL APPLICATIONS

VACUUM TECHNOLOGIES NEEDED FOR 3D DEVICE PROCESSING

Far UV Absorbance Detector

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

EE C245 / ME C218 INTRODUCTION TO MEMS DESIGN FALL 2009 PROBLEM SET #7. Due (at 7 p.m.): Thursday, Dec. 10, 2009, in the EE C245 HW box in 240 Cory.

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

Secondary Ion Mass Spectrometry (SIMS) Thomas Sky

Application Note S/SL

1. The range of frequencies that a measurement is sensitive to is called the frequency

Rapid Screening of PET Bottles for Residual Cleaning Solvents Using a LONESTAR TM Portable Analyzer

Distillation purification and radon assay of liquid xenon

Using 11.7eV PID Lamps To Accurately Measure VOCs With Ionization Energy Above 10.6eV

Microsensors. G.K. Ananthasuresh Professor, Mechanical Engineering Indian Institute of Science Bangalore, , India

FT-IR-iPAS A tool for industrial multicomponent gas measurement Christian Hirschmann 1,2 *, Jussi Tenhunnen 2, Satu Ojala 1,2 and Riitta Keiski 1

PHOTOELECTRON SPECTROSCOPY IN AIR (PESA)

Ion sources. Ionization and desorption methods

On Pulse Charging of Lead-Acid Batteries Cyril Smith, November 2010

Research Equipment in the UCA Chemistry Department

Warning!! Chapter 5 Gases. Chapter Objectives. Chapter Objectives. Chapter Objectives. Air Pollution

Portable type TXRF analyzer: Ourstex 200TX

Spectral Detection of Metal Contaminants in Water Using an On-Chip Microglow Discharge

o0, and since the period of vibration of the scale is related to the mass,

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP(

DISSOCIATION OF GAS IONS IN AIR BEFORE MASS SPECTROMETERS USING ELECTRIC FIELDS FROM FIELD DEPENDENT MOBILITY SPECTROMETERS

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

Characterization of Irradiated Doping Profiles. Wolfgang Treberspurg, Thomas Bergauer, Marko Dragicevic, Manfred Krammer, Manfred Valentan

Fluxless Soldering in Activated Hydrogen Atmosphere

IN-SITU MONITORING OF COMPOUNDS IN PLANETARY ATMOSPHERES USING A MINATURISED FIELD ASYMMETRIC ION MOBILITY SPECTROMETER

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

Selecting Detectors for Compounds with No Optical Absorbance

White Paper. Overview: NDIR Definition:

White Paper Adhesives Sealants Tapes

Chapter 31 Gas Chromatography. Carrier Gas System

Presented. Nayana.L MTech, CAID

PARTICLE ACCELERATORS

XPS/UPS and EFM. Brent Gila. XPS/UPS Ryan Davies EFM Andy Gerger

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Analytical techniques: Environmental samples. Lecture 2 Universidade do Algarve

Supporting Information. High Selectivity of Supported Ru Catalysts in the Selective. CO Methanation - Water Makes the Difference

Time of Flight Sensor with a Flow Parallel Wire

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

The Importance of Field Strength in the Low Field Portion of a Differential Ion Mobility Spectrometry Waveform

Transcription:

Miniaturized Sensor for the Detection of Environmental Pollutants Alexander Graf 1, Ronald Stübner 1, Christian Kunath 1, Sebastian Meyer 1, Harald Schenk 1 1 Fraunhofer Institute for Photonic Microsystems IPMS, Maria-Reiche-Str. 2, 01109 Dresden, Germany alexander.graf@ipms.fraunhofer.de Abstract A miniaturized ion mobility spectrometer (IMS) for the sensitive and selective detection of low concentrated substances in the ppb-range under atmospheric conditions is presented. The chip with a novel design consists of an integrated ion filter and detector and is manufactured with MEMS technologies. The implemented concept of the IMS-Chip allows an easy and flexible adaption to a broad range of target applications. Environmental analysis represents a possible field of application for the IMS-Chip. Concerning this, volatile organic compounds are substances of common interest. First promising results are presented which demonstrate the performance of the ion detector. An outlook for further investigations and the evaluation of the integrated ion filter is given. Key words: ion mobility spectrometer, sensitive and selective detection, MEMS technologies, volatile organic compounds, miniaturized sensor Introduction The fast and reliable detection of harmful substances places high demands on sensors and systems. Volatile organic compounds (VOC) are important especially in environmental analysis. Substances like benzene are very harmful to health even in low concentrations [1]. Common laboratory analysis methods are mass spectrometry and gas chromatography. Often they are also used in combination with special sample treatments to detect low concentrations of relevant substances. However, they are inconvenient for fast and portable in-situ analysis. Ion mobility spectrometry (IMS) is an alternative method, that allows a very sensitive and selective detection of e. g. warfare agents, drugs and VOCs [2]. IMS uses electrical fields to separate ionized analyte molecules of different species. In comparison to mass spectrometry, ion mobility spectrometers can be used directly in air under atmospheric conditions without the need for vacuum. Therefore, IMS represents a suitable method for portable and miniaturized gas detection systems. Concept of the new IMS-Chip Common realizations of IMS are based on timeof-flight (TOF) ion filters. A drift field moves the ions in a drift tube as depicted in Fig. 1 (a). According to eq. (1) the mean drift velocity v d of the ions depends on the electric field strength E and the specific ion mobility K. v d K E (1) The resulting drift time t d that an ion needs to get from the ion shutter to the detector depends on the length of the drift tube L: L t d. (2) K E The drift time t d can be used to distinguish different compounds of a unknown gas mixture. These kinds of drift tubes are relatively easy to implement. However, to achieve acceptable resolutions, e. g. to separate ion with similar ion mobilities, a sufficient drift length L is required. Therefore a miniaturization of the drift tube is limited. Towards smaller geometrical dimensions, inhomogeneities of the drift field especially near the side walls and the electrodes have a detrimental effect on the functionality. Therefore the use of MEMS technologies isn t preferable. Among other IMS realizations, like the aspiration condenser design [3], the so called differential ion mobility spectrometry (DMS) is a very promising filter technique for miniaturized ion mobility spectrometers. Fundamentals and miniaturized micromachined filters are described in Refs. [4] and [5]. DMS makes use of the field dependence of the ion mobility K(E). Ions are moved along planar filter electrodes while an alternating voltage produces an asymmetric electrical field. According to Fig. 1 (b), ions oscillates between the filter electrodes. Due to different electrical field conditions, ions are deflected perpendicular to the electrodes AMA Conferences 2017 SENSOR 2017 and IRS 2 2017 691

(a) (b) Fig. 1 Working principle of (a) time-of-flight ion mobility spectrometer TOF-IMS and (b) differential ion mobility spectrometer DMS with simplified ion trajectories. depending on their specific change of their ion mobility K(E). An additional dc compensation voltage adjusts the filter. Only ions with a special K(E) reach the ion detector behind the filter outlet. The value of the compensation voltage can be used, to distinguish different ion species. In general electric field strengths above 15 kv/cm are required for the filter operation. With regard to a portable detector system, relatively small voltages are required. To reduce the necessary voltages to a reasonable range of 100 V, distances between the filter electrodes of a few 10 µm are necessary. Therefore, the use of MEMS technologies is one promising possibility to fabricate such filter elements. In comparison with TOF-IMS, DMS has advantages regarding higher and continuous ion flows at the detector, as well as short measuring times. Despite that, additional load currents in the filter control are unavoidable. This is due to the needed alternating voltages and the electrical capacitance between the filter electrodes. The filter electronic have to provide this current. A miniaturized MEMS ion filter is described in Refs. [6] and [7]. The distance between the filter electrode is 35 µm. The filter structure is etched through a silicon chip. Deep reactive ion etching (DRIE) is therefore a suitable method. Ions are entering at the topside and exiting the chip at the bottom side. The small electrode distance allows very high electric field strengths and low voltages. However, adjustments in the filter geometry, e. g. for special fields of application, require high efforts regarding the adaption of the MEMS process. Furthermore, the ion detector is an additional part and is not integrated into the silicon chip. The IMS-Chip presented in this work (Fig. 2) is also based on DMS. In comparison to solution presented in Refs. [6] and [7], it uses a different concept for both the device and technical realization. The ion channels between the electrodes are orientated along the top side of the silicon chip. This allows the on-chip implementation of additional functional IMS parts like the ion detector. Furthermore, changes on the filter geometry towards a targeted application can be easily adapted. AMA Conferences 2017 SENSOR 2017 and IRS 2 2017 692

(a) (b) Fig. 2 Concept of the miniaturized IMS-Chip (a) the presented chip device and (b) cross sectional view for visualization of the internal gas channels and electrodes. The gas channels between the electrodes are covered with an additionally cap that has inlet and outlet slits for the gas transfer into the chip. The complete MEMS process takes place at wafer level. So the manufacturing process of the small devices is very cost-effective. This approach of an integrated and miniaturized ion filter and detector for use in an ion mobility spectrometer seems to be very advantageous. The design of the IMS-Chip allows a versatile adaption of filter and detector parameters while maintaining small electrode distances in the µm-range. This presents and advantage in comparison to other miniaturized IMS designs. Experimental An experimental setup according to Fig. 3 for the evaluation of the developed IMS-Chip has been developed. Analytes are mixed into the carrier gas flow by using permeation devices in a temperature controlled oven. The analyte is inside this device and permeates trough a membrane into the surrounding gas flow. With the help of these commercially available devices, low concentrations of several analytes can be produced over a long period of time. Concentrations can be varied with an additional mass flow controlled gas line. For first tests, acetone filled permeation tubes and pure nitrogen as carrier gas was used. Chemical ionization, e. g. with radioactive 63 Ni, and photoionization are two common methods for the ionization of the analytes. The current setup uses a discharge lamp (Heraeus Noblelight GmbH, PKS106) filled with krypton. These lamps emit photons with an energy of 10.0 ev and 10.6 ev. The ionized analytes enters the IMS-Chip and passes the ion filter and detector. the generation of the filter signal an electric circuit based on presented possibilities in Ref. [8] has been developed. Absolute analyte concentrations are measured with a photoionization detector (PID) after the IMS-Chip outlet. The PID has a separate photo discharge lamp and detects all ionized molecules in the gas stream without a filter element. The PID serves as a reference detector. Changes in analyte concentrations are performed by either changing the ratio from permeation and carrier gas flow or the temperature of the permeation oven. Obtained concentrations of acetone in nitrogen are in the range of a few ppb to a few 10 ppm. First Results and Discussion The IMS-Chip includes the functional main components ion filter and detector. Important parameters of the ion detector like sensitivity, dynamic behavior and stability of the detector signal was determined. Tests of the functionality of the ion filter can be evaluated. This will be published elsewhere. The detector converts the gas flow with the ionized analytes into an electric current. The sensitivity is defined as the change of this ion current in dependence of the analyte concentration. Therefore this value influences the absolute ion current at a given concentration. In general this value is in the na to pa range. Fig. 4 shows an exemplary characteristic curve of the detector signal obtained with the IMS-Chip. A linear dependence of the detector current is observed in the lower ppm concentration range. For the measurement of the ion current an electrometer (Keithley 6517B) has been used. For AMA Conferences 2017 SENSOR 2017 and IRS 2 2017 693

permeation device discharge lamp Fig. 3 The developed IMS-Chip with integrated ion filter and detector and the test setup with carrier gas, sample gas, ion source (VUV-photo discharge lamp) and a photoionization detector (PID) after the gas outlet of the IMS-Chip. The measurement results show also a stable detector signal when applying a constant analyte concentration. Fig. 4 Characteristic curve of the detector signal The time that a sensor needs to respond on concentration changes is another important parameter. This dynamic behavior is evaluated by a fast change in the analyte concentration while keeping the electrical parameters of the IMS-Chip constant. In the exemplary response curve in Fig. 5, the concentration of the test gas acetone has changed from 0 to 2 ppm. The ion detector of the IMS-Chip shows a response time of a few minutes. The reference detector shows a comparable response time. 2 ppm acetone 0 ppm acetone 2 ppm acetone Fig. 5 Dynamic behavior and stability of the detector signal. These first measurements indicates the basic functionality of the ion detector as a part of the IMS-Chip. There are also some effects, that cannot be explained so far. That are the change of the sensitivity towards low concentrations below 200 ppb and a overshoot of the detector signal after a change of the analyte concentration. Additional measurements and adaptions of the experimental setup have to be performed. We attribute this characteristic to an too long distance that the ions have to move from the ionization source to the IMS-Chip. The realization of an improved version of the setup is in progress. Basing on these results and the applied corrections of the experimental setup, the evaluation of the ion filter can be performed. Conclusion and Outlook The presented IMS-Chip with a unique component design combines an ion filter and detector in one single miniaturized device. An experimental setup was developed to characterize the manufactured MEMS chips. First results indicate a linear response in the upper ppb range and short response times. Next steps will include further tests of the detector element and the ion filter. Afterwards the overall IMS-Chip functionality can be evaluated. The concept of the presented IMS-Chip is a promising approach, that can be used as a part of an ion mobility spectrometer for the detection of a broad range of substances, like volatile organic compounds. References [1] J. Huff, International Journal of Occupational and Environmental Health 13, 213 221 (2007); doi: 10.1179/oeh.2007.13.2.213 AMA Conferences 2017 SENSOR 2017 and IRS 2 2017 694

[2] G. A. Eiceman, Z. Karpas, H. H. Hill Jr, Ion mobility spectrometry, 3rd edition, CRC Press (2014) [3] S. Zimmermann, N. Abel, W. Baether, S. Barth, An ion-focusing aspiration condenser as an ion mobility spectrometer, Sensors and Actuators B: Chemical 125, 428 434 (2007); doi: 10.1016/j.snb.2007.02.038 [4] I. A. Buryakov, E. V. Krylov, E. G. Nazarov, U.Kh. Rasulev, A new method of separation of multiatomic ions by mobility at atmospheric pressure using a high-frequency amplitude-asymmetric strong electric field, International Journal of Mass Spectrometry and Ion Processes 128, 143 148 (1993) doi: 10.1016/0168-1176(93)87062-W [5] R. A. Miller, G. A. Eiceman, E. G. Nazarov, A. T. King, A novel micromachined high-field asymmetric waveform-ion mobility spectrometer, Sensors and Actuators B: Chemical 67, 300 306 (2000); doi: 10.1016/S0925-4005(00)00535-9 [6] A. A. Shvartsburg, R. D. Smith, A. Wilks, A. Koehl, D. Ruiz-Alonso, B. Boyle, Ultrafast differential ion mobility spectrometry at extreme electric fields in multichannel microchips, Analytical chemistry 81, 6489 6495 (2009); doi: 10.1021/ac900892u [7] A. Wilks, M. Hart, A. Koehl, J. Somerville, B. Boyle, D. Ruiz-Alonso, Characterization of a miniature, ultra-high-field, ion mobility spectrometer, International Journal for Ion Mobility Spectrometry 15, 199 222 (2012); doi: 10.1007/s12127-012-0109-x [8] E. V. Krylov, Pulses of Special Shapes Formed on a Capacitive Load. Instruments and Experimental Techniques 40, 628 631 (1997); AMA Conferences 2017 SENSOR 2017 and IRS 2 2017 695