E X - C E I L I N G, P E N D A N T L I G H T F I T T I N G S A N D F L O O D L I G H T S

Size: px
Start display at page:

Download "E X - C E I L I N G, P E N D A N T L I G H T F I T T I N G S A N D F L O O D L I G H T S"

Transcription

1 1 E X - C E I L I N G, P E N D A N T L I G H T F I T T I N G S A N D F L O O D L I G H T S EX- CEILING LIGHT FITTINGS EX- PENDANT LIGHT FITTINGS EX- FLOODLIGHTS EX- VESSEL LIGHT FITTING ZONE 2/ 22 EX- PENDANT LIGHT FITTINGS ZONE 2/ 22 EX- FLOODLIGHTS ACCESSORIES 4.

2 I Ex-ceiling, pendant light fittings and floodlights I Field of application of pendant light fittings and floodlights with high pressure discharge lamps in hazardous areas. Where a lot of light is needed and/or where large complexes or areas have to be illuminated, or where there are high ceilings, these are the ideal situations for pendant light fittings and floodlights. The main field of operation is the illumination in hazardous explosive environments such as On- and Offshore areas, production and storage buildings or Ex-companies in the chemical industry. Also the illumination of outside areas such as loading zones, harbour areas or even refineries. The pendant light fittings and floodlights are usually fitted with high pressure discharge lamps such as Metal halide lamp or Sodium vapour lamps. They offer a high output of light and a relatively long life span. Due to environmental protection the use of Mercury Vapor lamps have been forbidden in more and more countries. The typ of lamp may be replaced by other light sources e.g. Metal halide or sodium vapour lamps. 4.2 C O O P E R C R O U S E - H I N D S G M B H

3 I Ex-ceiling, pendant light fittings and floodlights I 1 2 With the CEAG pendant light fittings and floodlights for the Zones 1, 2, 21 and 22 you have a safety assurance even in difficult environmental con - ditions such as high and low temperature, high humidity, dusty and aggres - sive explosive atmospheres. The high safety standard required is assured for even after a long period of usage time. A long service life and the high reliability factor of the used electrical and mechanical components makes these lamps extremely cost-effective. Especially the innovative illuminant technology of the induction lamps used in the EVQ light fittings guarantees a lamp life expectancy of >,000 hours. This makes these light fittings destinied for usage in uncomfortable and hard to access areas where one can efficiently minimize the maintanance costs. Pendant light fitting EVQ for Induction lamps The easy changing of the lamp, for example in the new CEAG floodlight series FZD (you just change the complete lamp module), also effectively reduces the maintanance costs. Even in extreme environments and temperatures of -40 C you can be sure that the light fittings will be quickly back in use. The actual lamp replacement can then take place in the work-shop at a later date Bulk head light fitting AB 05 8 FZD flood light C O O P E R C R O U S E - H I N D S G M B H 4.

4 E X - C E I L I N G L I G H T F I T T I N G S AB 05, AB 80 and AB NAV 0 Metal Version for Zone 1 and 21 AB 05 This explosion-protected light fitting for Incan - descent as well for high pressure discharge lamps is designed in accordance to the ATEX- Directive 4//EG. The light fittings are fitted with an impact resis - tant and thermally stable dome-shaped glass. All external screws are made of high quality stainless steel. The distinguishing characteristics of this series are the low weight and the simple installation. The control gear for HPS-lamps is installed on a removeable support in order to make the maintenance easy. The AB 05 series offers a wide range of application using different type of explosion protection: Ex e IIC for Zone 1/21 Ex de IIB (+H2 as an option) for Zone 1/21 Ex nr for Zone 2/22 An internal aluminium reflector enables a well balanced light distribution characteristic. AB 80 Due to the flameproof design all types of incandescent lamps up to 0 W or suitable compact fluorescent lamps with electronic ballast can be used. The AB 80 light fitting is a flat light fitting for ceiling mounting. Due to their robust architecture, this light fitting is suitable for use in the chemical industry and have been certified for usage in environments with a temperature of up to +55 C. AB NAV 0 This compact Ex-d light fixture for high pressure sodium lamps allows individual lighting solutions for areas with limited mounting space. Lamp, ballast capacitor and ignitor are incorporated on a compact module, which allows easy re-lamping and maintenance procedure. An optional external reflector allows individual illumination of working places. Certified for environmental temperatures from -55 C up to +55 C, depend. on type Fulfils highest requirements on corrosion protection and mechanical stability Robust light alloy housing (AB 05, AB NAV 0) Easy installation High quality stainless steel screws, easier lamp replacement 4.4

5 I Ex-ceiling light fittings I 1 2 Technical data AB 05 Ex nr AB 05 Ex de Ex-Bulkhead light fitting AB 05 Marking to 4//EC AB 05 Ex-e II 2 G Ex de IIC T/T2 II 2 D Ex td A21 IP66 T5 C AB 05 Ex-d II 2 G Ex d IIB (+H2) T4/T AB 05 nr II G nr II T4/T II D Ex td A22 IP66 T0/5/140 C EC-Type Examination Certificate AB 05 Ex-e BVS 0 ATEX E 152 X AB 05 Ex-d PTB 08 ATEX 01 X Type Examination Certificate AB 05 nr BVS 0 ATEX E 151 Permissable ambient temperature 20 C to +40 C 55 C to +55 C (option, depends on version) Rated voltage max. 250 V 2) (AB 05 Ex e/nr) 2 V (AB 05 Ex d) Frequency 50 - Hz Connecting terminals L1, N, 1 x mm 2, PE: 2 x mm 2 Insulation class I Lamp/Illuminant Degree of protection accd. EN 52 IP66 Cable glands/gland plates/enclosure drilling 1 x M20/M25 x 1.5 / 2 x M20/25 x 1.5 one plugged, or 1 x /4 ISO /1/ 2 x /4 ISO /1 one plugged Dimensions (L x W x H) x 2 x 15 mm Weight Type of mounting ceiling/wall mounting Enclosure material light alloy Enclosure colour grey Protective cover/protective bowl borosilicate glass Enclosure earth 2 x 6 mm 2 see ordering details 2) other voltages on request Dimension drawing Polar curves >40 >40 AB 05 Polar curve AB 05 Ex de Polar curve AB 05 nr 5 C 0 C l/cd/klm 5 C 0 C l/cd/klm Dimensions in mm C O O P E R C R O U S E - H I N D S G M B H 4.5

6 I Ex-ceiling light fittings I AB 05 Ex de AB 05 Ex nr Ordering details Type Type of lamp Rated Temperature Cable glands/threads Weight/ Qty. Order No. luminous class kg flux 2) II 2 G IIC ( 20 C up to +55 C) AB 05 Ex de incandescent max. W lm T/T2 1 x M AB AB 05 Ex de incandescent max. W lm T/T2 2 x M20, 1 x Ex-e M AB AB 05 Ex de incandescent max. W lm T/T2 1 x M AB AB 05 Ex de incandescent max. W lm T/T2 2 x M25, 1 x Ex-e M AB II G Ex nr II (- 50 ºC up to + 55 ºC) AB 05 nr 0 W HSE 50 lm T4 1 x M AB AB 05 nr 0 W HSE 50 lm T4 2 x M20, 1 x Ex-e M AB AB 05 nr 0 W HSE 50 lm T4 1 x M AB AB 05 nr 0 W HSE 50 lm T4 2 x M25, 1 x Ex-e M AB AB 05 nr 0 W HSE ) 50 lm T4 1 x M AB AB 05 nr 0 W HSE ) 50 lm T4 2 x M25, 1 x Ex-e M AB AB 05 nr 80 W HME 800 lm T4 1 x M AB AB 05 nr 80 W HME 800 lm T4 1 x M25, 1 x Ex-e plug AB AB 05 nr 200 W HME 0 lm T 1 x M AB AB 05 nr 200 W HME 0 lm T 1 x M AB II 2 G IIB +H2 (- 20 ºC up to + 55 ºC) AB 05 Ex d 0 W HSE 50 lm T4 1 x M20 thread 6. 1 AB AB 05 Ex d 0 W HSE ) 50 lm T4 1 x M20 thread 6. 1 AB AB 05 Ex d 0 W HSE 50 lm T4 1 x Ex d NPT 1/2 thread 6. 1 AB AB 05 Ex d 0 W HSE 50 lm T4 2 x Ex d NPT 1/2 thread 6. 1 AB AB 05 Ex d 0 W HSE 50 lm T4 1 x Ex d NPT /4 thread 6. 1 AB AB 05 Ex d 0 W HSE 50 lm T4 2 x Ex d NPT /4 thread 6. 1 AB AB 05 Ex d 0 W HSE ) 50 lm T4 1 x Ex d NPT /4 thread 6. 1 AB AB 05 Ex d 0 W HSE 50 lm T4 1 x M20 thread 6. 1 AB x M20 plug AB 05 Ex d 0 W HSE ) 50 lm T4 1 x M20 thread 6. 1 AB II 2 G IIB (- 20 ºC up to + 55 ºC) AB 05 Ex d 0 W HSE 50 lm T4 1 x M20 thread 6. 1 AB AB 05 Ex d 0 W HSE ) 50 lm T4 1 x M20 thread 6. 1 AB AB 05 Ex d 0 W HSE 50 lm T4 1 x Ex d NPT 1/2 thread 6. 1 AB AB 05 Ex d 0 W HSE 50 lm T4 2 x Ex d NPT 1/2 thread 6. 1 AB AB 05 Ex d 0 W HSE 50 lm T4 1 x Ex d NPT /4 thread 6. 1 AB AB 05 Ex d 0 W HSE ) 50 lm T4 1 x Ex d NPT /4 thread 6. 1 AB AB 05 Ex d 0 W HSE 50 lm T4 1 x M20 thread 6. 1 AB x M20 plug AB 05 Ex d 0 W HSE ) 50 lm T4 1 x M20 thread 6. 1 AB AB 05 Ex d 0 W HSE 50 lm T4 2 x Ex d NPT /4 thread 6. 1 AB T only with lamp accd. to EN 064 and DIN 48 marked T 2) depends on used lamps ) for HSE lamps with integrated ignitor Lamps and fixing accessories are not included. Metal cable glands see page C O O P E R C R O U S E - H I N D S G M B H

7 I Ex-ceiling light fittings I 1 2 Technical data AB 80 Ex-Bulkhead light fitting AB 80 Marking to 4//EC II 2 G Ex d IIB T4 (up to 0 W) / T6 ( W PL) EC-Type Examination Certificate LOM 01 ATEX 2041 X Permissable ambient temperature 20 C C Rated voltage max. 250 V Connecting terminals 1 x 2.5 mm 2 or 2 x 1.5 mm 2 ; PE 2 x 6 mm 2 Insulation class I Incandescent lamp W, 0 W Lamp/Illuminant TC-DSE W Lamp cap E 2 Rated luminous flux lm / 1 lm / 6 lm Light efficiency in operation % Degree of protection accd. EN 52 IP55 Cable glands/gland plates/enclosure drilling 2 x /4 ISO /1-/2 x M25 x 1.5 thread (Ex-d), one plugged Weight 6. kg Type of mounting wall/ceiling mounting Enclosure material cast iron Enclosure colour grey Protective cover/protective bowl mechanical and chemical high resistent glass Enclosure earth 2 x 6 mm 2 depends on lamp Ordering details Type Entry thread Cable gland Ex-d for cable Ø Blanking plug Ex-d Order No. AB 80 with cable gland 2 x /4-14 mm 1 x /4 NOR AB 80 2 x /4 1 x /4 NOR AB 80 2 x M25 1 x M25 NOR Lamps and fixing accessories are not included Accessories Type Content Application Order No. GAB 80 wire guard AB 80 NOR REP.AB 80 spare glass AB 80 NOR Metal cable glands see page 8... Dimension drawing entry optional entry, on request AB 80 Dimensions in mm C O O P E R C R O U S E - H I N D S G M B H 4.

8 I Ex-Bulkhead light fitting I AB NAV 0 Technical data Ex-Bulkhead light fitting AB NAV 0 Marking to 4//EC II 2 G Ex d IIC / IIB T / II 2 D Ex td A21 IP6 T1 C EC-Type Examination Certificate LOM 02 ATEX 201 X IECEx Certificate of Conformity IECEx BKI X Marking accd. to IECEx Ex d IIC / IIB T Permissible amient temperature 20 C to +55 C Gas group IIC 45 C to +55 C Gas group IIB Rated voltage 2 V Rated current 0,6 A Frequency 50 Hz Power factor cos ϕ 0, Connecting terminals L1, N, PE: 2 x 2.5 mm 2, PE 2 x 6 mm 2 Insulation class I Lamp/Illuminant HSE 0 W Lamp cap E 2 Rated luminous flux 50 lm Light efficiency in operation 0 % Degree of protection accd. EN 52 IP6 Cable glands/gland plates/enclosure drilling 2 x /4 ISO /1 thread (Ex-d) one plugged Weight 5. kg Type of mounting Wall/ceiling mounting Enlcosure material light alloy Enclosure colour grey Protective cover Borosilicate glass tube depends on lamp 4.8 C O O P E R C R O U S E - H I N D S G M B H

9 I Ex-Bulkhead light fitting I 1 2 Ordering details AB NAV 0 Type Entry thread Cable gland Blanking plug Qty. Order No. Ex-d for cable Ø Ex-d Group IIC - NORMAL (ambient temperature) ( 20 C to +55 C) AB NAV 0 + PE 2 x / x /4 1 NOR AB NAV 0 2 x /4 1 x /4 1 NOR Group IIB - LOW (ambient temperature) (up to 45 C) AB NAV 0 2 x /4 1 x /4 1 NOR Lamps and fixing accessories are not included Accessories 5 AB NAV 0 Type Content Order No. D 2 Ceiling bracket with screws and polyamide washer (CrNi, 2 pcs.) A5 Ceiling bracket hot galvanized (1 pc.) NOR BFP45 Wall bracket 45 hot galvanized (1 pc.) NOR RAB 8 Reflector AISI 4 NOR RAB 8 Reflector AISI 4 + guard (steel white epoxy coating) NOR RAB 8 Reflector AISI 16 NOR RAB 8 Reflector AISI 16 + guard (steel white epoxy coating) NOR Metal cable glands see page 8... Dimensions drawing Polar curve M8xmm 8 26 optional entry, on request entry 4 AB NAV 0 Polar curve AB NAV C 0 C l/cd/klm Dimensions in mm C O O P E R C R O U S E - H I N D S G M B H 4.

10 E X - P E N D A N T L I G H T F I T T I N G S for incandescent and high pressure discharge lamps up to 500 W Metal version for Zone 1/21 All explosion-protected pendant light fittings for Incandescent, high pressure discharge and Induction lamps are in accordance with the ATEX-Directive 4//EG. AB 50/SPG 1N and AB51 Due to their compact design the series AB 50, SPG 1N and AB 51 are designed for individual illumination of a local area. Beside the copperfree aluminium housings all external screws are made of stainless steel. The protective glass dome is made of borosilicate glass which has a high mechanical and thermic stability. This ensures a save use even in harsh environmental areas. Most of the world-wide field conditions can be accepted by the large permissible ambient temperature range from 50 C up to +55 C. EVI and EV The housing is made of a copper-free aluminium. The ballast for the high pressure discharge lamps (EVM/EVS/EVH) is thermically separated in its own compartment in the top part of the housing. The dome-shaped glass enclosure is made of borosilicate glass which has a high mechanical and thermic stability. All external screws and the reflector are made of stainless steel. The lamp replacement is done by opening the PTFE coated connection ring. Both the glass enclosure and the connection ring are hinged for easy access. Due to their robust architecture, these light fittings are suitable for use in the chemical industry and have been certified for usage in environments with a temperature of up to +55 C (EVQ excluded). The new light fitting EVQ, designed for lamp replacement in > 000 hour intervals are fitted with induction lamps and a high-frequency generator. For environmental temperatures range of 50 C up to +55 C (EVQ excluded) Safety Standard IP6 Robust light alloy housing Easy opening of lamp compartment 4.

11 I Ex-Pendant light fittings I 1 2 Technical data SPG 1N AB 50 IXM AB 50 IU AB 50 SPG 1N Marking to 4//EC II 2 G Ex d IIC T (direct entry IU); T4 with W at tamp +40 C (new standard applied for) II 2 G Ex de IIC T (indirect entry IXM) II 2 D Ex td IP6 T180 C, T1 with W at +40 C EC-Type Examination Certificate LOM 02 ATEX 2018 X Permissible ambient temperature -20 C to +55 C -50 C to +55 C (option: AB 50) Rated voltage max. 250 V Power consumption max. 0 W Connecting terminals 1 x 2.5 mm 2 / 2 x 1.5 mm 2 (IU and SPG1N), 2 x 2.5 mm 2, PE 2 x 6 mm 2 (IXM) Insulation class I Incandescent lamp W, 0 W, 5 W halogene 2) Lamp cap E 2 Rated luminous flux lm / 1 lm Light efficiency in operation 68 % Degree of protection accd. EN 52 IP6 Cable glands/gland plates/enclosure drilling 2 x /4 ISO /1-thread (Ex-d), one plugged (UI) / 2 x M25 x 1,5 (IXM), SPG1N incl. cable gland Dimensions (L x W x H) see dimension drawing Weight see table Type of mounting ceiling mounting Enclosure material light alloy Enclosure colour grey Protective cover/protective bowl borosilicate glass depends on lamp 2) 5 W halogene lamp max ta = +40 C C O O P E R C R O U S E - H I N D S G M B H 4.

12 I Ex-Pendant light fittings I AB 50 IU AB 50 IXM SPG 1N Ordering details Type Entry thread Cable gland Blanking plug Weight Order No. for cable Ø (T ambient -20 C to +55 C) AB 50 IU (direct entry) 2 x /4-14 mm Ex-d 1 x /4 Ex-d 1.6 kg NOR AB 50 IU (direct entry) 2 x /4 1 x /4 Ex-d 1.5 kg NOR AB 50 IXM (indirect entry) 2 x M25 x mm Ex-e 1 x M25 x 1.5 Ex-e 2. kg NOR AB 50 IXM (indirect entry) 2 x M25 x x M25 x 1.5 Ex-e 2.2 kg NOR SPG 1N (portable light fixture) 1 x /4-14 mm Ex-d 2.2 kg NOR (T ambient -50 C to +55 C) AB 50 IU (direct entry) 2 x /4 1 x /4 Ex-d 1.6 kg NOR AB 50 IXM (indirect entry) 2 x M25 x x M25 x 1.5 Ex-e 2.2 kg NOR Lamps and fixing accessories are not included Accessories AB 50/SPG 1N Type Content Application Order No. REP AB 50 Spare glass AB 50 NOR WG Wire guard, galvanized AB 50 NOR ER External reflector, coated AB 50 NOR CEV / AB Eye bolt galvanized AB 50 NOR AS. EV Ceiling bracket, galvanized AB 50 NOR Metal cable glands see page 8... Dimensions drawing Polar curve Ø5 Ø5 5 AB 50 IU AB 50 IXM SPG 1N entry optional entry, on request Polar 0 curve 0 AB 50 IU 25 C 0 C l/cd/klm Dimensions in mm 4. C O O P E R C R O U S E - H I N D S G M B H

13 I Ex-Pendant light fittings I 1 2 Technical data AB 51 M/S...V AB 51 IX AB 51 IU AB 51 IU AB 51 IX AB 51 M/S... Marking to 4//EC II 2 G Ex de IIC T (indirect entry IX) / Ex d IIC T (direct entry) (new standard applied for) II 2 D Ex td A21 IP6 T C EC-Type Examination Certificate LOM 02 ATEX 2020 X IECEx Certificate of Conformity IECEx BKI X Marking acc. to IECEx Ex d/de IIC T Ex td A21 IP6 T Permissible ambient temperature -20 C to +55 C -45 C to +55 C (AB 51 M/S) -50 C to +55 C (option) Rated voltage max. 250 V (AB 51..) / 2 V AC AB 51 M/S ) Power factor cos ϕ 0.85 (AB 51 M/S) Connecting terminals 1 x 2.5 mm 2 / 2 x 1.5 mm 2 (IU), 2 x 2.5 mm 2 (IX and M/S), PE ext. 2 x 6 mm 2 Insulation class Lamp/Illuminant Lamp cap E 2 Rated luminous flux2) 2) Light efficiency in operation 5 % Degree of protection accd. EN 52 Cable glands/gland plates/enclosure drilling 2 x /4 ISO /1-thread (Ex-d), one plugged (UI and M/S) / Dimensions (L x W x H) Weight Type of mounting Enclosure material Enclosure colour Protective cover/protective bowl Additional lamp data I IP6 2 x M25 x 1.5 one plugged (IX) 2 mm x Ø 205 mm (IU), 400 x Ø 205 mm (IX), 425 x Ø 205 (M/S) see ordering information ceiling mounting light alloy grey borosilicate glass Lamp Luminous Power Temperature class II 2 G Max. surface temp. II 2 D flux 2) Tambient 40 C Tambient > 40 C Tambient 40 C Tambient > 40 C Incandescent IGA lm 150 W T T T 12 C T 14 C Incandescent IGA 80 0 lm 200 W T T T 1 C T 152 C Halogene lamp IQT 00 lm 5 W T5 T4 T 88 C T C Halogene lamp IQT 2500 lm 150 W 4) T4 T T C T 18 C Compact Fuorescent Lamp TC-TSE 0/00 lm W 5) T6 T6 T C T 5 C High pressure mercury vapor mixed light HME-SB 00 lm 0 W T4 T4 T 0 C T 5 C High pressure mercury vapor mixed light HME-SB 0 lm 1 W T T T C T 142 C High pressure mercury vapor HME 800 lm 80 W T4 T4 T 2 C T C High pressure mercury vapor HME 60 lm 5 W T T T C T 142 C High pressure sodium lamp HSE 400 lm 50 W T5 T4 T 86 C T 1 C High pressure sodium lamp HSE 50 lm 0 W T4 T4 T C T 2 C see table 2) depends on lamp ) others on request 4) Tamp max. +40 C 5) Tamp max. + C C O O P E R C R O U S E - H I N D S G M B H 4.1

14 I Ex-Pendant light fittings I AB 51 IU AB 51 IX AB 51 M/S...V Ordering details Type Lamp Entry thread Cable gland Blanking plug Weight Order No. for cable Ø (T ambient -20 C up to +55 C) AB 51 IU (direct entry) all 2 x /4 1 x /4 Ex-d.6 kg NOR AB 51 IX (indirect entry) all 2 x M25 x x M25 Ex-e 4.5 kg NOR AB 51 M 5 V (direct entry) 2) 5 W HME 2 x /4 1 x /4 Ex-d.5 kg NOR AB 51 S 0 V (direct entry) 2) 0 W HSE 2 x /4 1 x /4 Ex-d.5 kg NOR (T ambient -50 C up to +55 C) AB 51 IU (direct entry) all 2 x /4 1 x /4 Ex-d.6 kg NOR AB 51 IX (indirect entry) all 2 x M25 x x M25 Ex-e 4.5 kg NOR (T ambient -45 C up to +55 C) AB 51 M 5 V (direct entry) 2) 5 W HME 2 x /4 1 x /4 Ex-d.5 kg NOR AB 51 S 0 V (direct entry) 2) 0 W HSE 2 x /4 1 x /4 Ex-d.5 kg NOR Lamps and fixing accessories are not included 2) including flameproof enclosure with complete control gear Accessories AB 51 Content Application Order No. Spare glass with metal ring AB 51 NOR Wire guard AB 51 NOR External reflector AB 51 NOR Ceiling bracket ANSI 16 AB 51 NOR Eye bolt ANSI 16 AB 51 NOR Dimensions drawing Polar curve Ø2 Ø2 Ø2 optional entry, on request entry AB 51 IU AB 51 IX AB 51..V Polar curve AB 51 IU 5 45 C l/cd/klm Dimensions in mm 4.14 C O O P E R C R O U S E - H I N D S G M B H

15 I Ex-Pendant light fittings I 1 2 EVI 500 XM Technical data EVI 500 UD EVI 200 XM EVI 200 UD EVI 200 EVI 500 Marking to 4//EC II 2 G Ex d IIC T (direct entry UD) (new standard applied for) II 2 G Ex de IIC T (indirect entry XM) II 2 D Ex td A21 IP6 T C EC-Type Examination Certificate LOM 02 ATEX 20 X IECEx Certificate of Conformity IECEx BKI 0.001X Marking acc. to IECEx Ex d / de IIC T Ex td A21 IP6 T Permissible ambient temperature -20 C to +55 C -50 C to +55 C Rated voltage max. 250 V Connecting terminals 1 x 2.5 mm 2 / 2 x 1.5 mm 2 (UD), 2 x 2.5 mm 2 (XM); PE ext. 2 x 6 mm 2 Insulation class I Lamp/Illuminant Lamp cap E 2 (EVI 200) / E 40 (EVI 500) Rated luminous flux Light efficiency in operation 5 % Degree of protection accd. EN 52 IP6 Cable glands/gland plates/enclosure drilling 2 x /4 ISO /1-thread (Ex-d), one plugged (UD) / 2 x M25 x 1.5, on plugged (XM) Dimensions (L x W x H) 280 mm x Ø 245 mm (200 UD), 400 x Ø 225 mm (200 XM) 40 mm x Ø 0 mm (500 UD), 4 x Ø 0 mm (500 XM) Weight see ordering information Type of mounting ceiling mounting Enclosure material light alloy Enclosure colour grey Protective cover/protective bowl borosilicate glass Additional lamp data Lamp Luminous Power Type Temperature class II 2 G Max. surface temp. II 2 D flux 2) Tambient +40 C Tambient +55 C Tambient +40 C Tambient +55 C Incandescent IGA lm 150 W EVI 200 T4 T4 T5 ºC T0 ºC Incandescent IGA 80 0 lm 200 W EVI 200 T4 T4 T5 ºC T1 ºC Incandescent IGA 5000 lm 0 W EVI 500 T4 T4 T5 ºC T1 ºC Incandescent IGA lm 500 W EVI 500 T T T155 ºC T10 ºC High pressure mercury vapor mixed light HME-SB 0 lm 1 W EVI 200 T4 T T5 ºC T140 ºC High pressure mercury vapor mixed light HME-SB 50 lm 250 W EVI 500 T4 T T5 ºC T140 ºC High pressure mercury vapor HME 800 lm 80 W EVI 200 T4 T4 T5 ºC T1 ºC High pressure mercury vapor HME 60 lm 5 W EVI 200 T4 T4 T5 ºC T1 ºC High pressure mercury vapor HME 0 lm 250 W EVI 500 T4 T T5 ºC T140 ºC High pressure sodium lamp HSE 50 lm 0 W EVI 200 T5 T4 T 5 ºC T0 ºC High pressure sodium lamp HSE lm 150 W EVI 500 T5 T4 T ºC T5 ºC High pressure sodium lamp HSE lm 250 W EVI 500 T4 T4 T5 ºC T140 ºC High pressure Metal Halide HIE 1000 lm 250 W EVI 500 T4 T T5 ºC T140 ºC see table 2) depends on lamp C O O P E R C R O U S E - H I N D S G M B H 4.15

16 I Ex-Pendant light fitting I EVI 200 UD EVI 200 XM EVI 500 UD EVI 500 XM Ordering details Type Entry thread Cable gland Blanking plug Weight Order No. for cable Ø kg (T ambient -20 C to +55 C) EVI 200 UD (direct entry) 2 x /4-14 mm Ex-d 1 x /4 Ex-d 8. NOR EVI 200 UD (direct entry) 2 x /4 1 x /4 Ex-d 8.20 NOR EVI 500 UD (direct entry) 2 x /4-14 mm Ex-d 1 x /4 Ex-d. NOR EVI 500 UD (direct entry) 2 x /4 1 x /4 Ex-d.80 NOR EVI 200 XM (indirect entry) 2 x M25 x mm Ex-e 1 x M25 Ex-e. NOR EVI 200 XM (indirect entry) 2 x M25 x x M25 Ex-e.00 NOR EVI 500 XM (indirect entry) 2 x M25 x mm Ex-e 1 x M25 Ex-e 1.0 NOR EVI 500 XM (indirect entry) 2 x M25 x x M25 Ex-e 1. NOR (T ambient -50 C to +55 C) EVI 200 UD (direct entry) 2 x /4 1 x /4 Ex-d 8.20 NOR EVI 500 UD (direct entry) 2 x /4 1 x /4 Ex-d.80 NOR EVI 200 XM (direct entry) 2 x /4 1 x /4 Ex-d.00 NOR EVI 500 XM (direct entry) 2 x /4 1 x /4 Ex-d 1. NOR Versions for high pressure lamps (HME, HSE, HIE): flameproof ballast enclosure not included Lamps and fixing accessories are not included Accessories EVI 200, EVI 500 Type Content Application Order No. REP 200 Spare Glass EVI 200 NOR REP 500 Spare glass EVI 500 NOR G. EV 200 Wire Guard EVI 200 NOR G. EV 500 Wire Guard EVI 500 NOR PC. EV 200 External reflector EVI 200 / EVQ 55 NOR PC. EV 500 External reflector EVI 500 / EVQ 85 NOR KEY, EV Lamp key EV... NOR CEV/AB Eye bolt EV... NOR AS. EV Ceiling bracket,adjustable EV... NOR SPU. EV Wall mounting barcket EV... NOR BC. EV Pole mounting bracket EV... NOR SP. EV 200 Wall mounting bracket EVI 200 NOR SP. EV 500 Wall mounting bracket EVI 500 NOR Metal cable glands see page C O O P E R C R O U S E - H I N D S G M B H

17 I Ex-Pendant light fitting I 1 2 EVI 500 UD EVI 500 XM Dimensions drawing Polar curve EVI 200 XM EVI 200 UD Ø 245 entry optional entry, on request Ø 245 Ø 0 Ø 0 5 EVI 200 UD EVI 200 XM EVI 500 UD EVI 500 XM ø 8 BC. EV/AB SP.EV 200/500. /4 KEY.EV CEV/AB AS.EV/AB Polar 0 curve EVI 200/500 0 without external reflector /4 ø Polar curve EVI 200/500 with external reflector C 0 C l/cd/klm 5 45 C l/cd/klm Dimensions in mm C O O P E R C R O U S E - H I N D S G M B H 4.1

18 I Ex-Pendant light fitting I EVQ 55 UD EVQ 55 XM EVQ 85 UD EVQ 85 XM Technical data EVQ QL-lamps Marking to 4//EC II 2 G Ex d IIC T6 (direct entry UD) (new standard applied for) II 2 G Ex de IIC T6 (indirect entry XM) II 2 D Ex td A21 IP6 T85 C EC-Type Examination Certificate LOM 02 ATEX 20 X IECEx Certificate of Conformity IECEx BKI 0.001X Marking acc. to IECEx Ex d / de IIC T6 Permissible ambient temperature -20 C to +55 C Rated voltage 2 V AC/DC Rated current 0.26 A (55 W), 0.40 A (85 W) Frequency 50/ Hz Power factor cos ϕ > 0.6 Circuit electronic HF generator Connecting terminals 1 x 2.5 mm 2 / 2 x 1.5 mm 2 (UD), 2 x 2.5 mm 2 (XM); PE ext. 2 x 6 mm 2 Insulation class I Lamp/Illuminant Induction lamp 55/85 W with coupler Rated luminous flux 55 W: 500 lm / 85 W: 00 lm Light efficiency in operation 66 % Degree of protection accd. EN 52 IP6 Cable glands/gland plates/enclosure drilling 2 x /4 ISO /1-thread (Ex-d), one plugged (UD), 2 x M25 thread (Ex-e), one plugged (XM) Dimensions (L x W x H) 280 mm x Ø 245 mm (55 UD), 400 x Ø 225 mm (55 XM), 40 mm x Ø 0 mm (85 UD), 4 x Ø 0 mm (85 XM), Weight see ordering information Type of mounting ceiling mounting Enclosure material light alloy Enclosure colour grey, PTFE (optional) Protective cover/protective bowl borosilicate glass, opaque (clear on request) Fixing accessories are not included, included lamps and HF generator 4.18 C O O P E R C R O U S E - H I N D S G M B H

19 I Ex-Pendant light fitting I 1 2 EVQ 85 XM Ordering details EVQ 85 UD EVQ 55 XM EVQ 55 UD Type Entry thread Cable gland Blanking plug Weight Order No. for cable Ø EVQ 55 UD (direct entry 2 x /4-14 mm Ex-d 1 x /4 Ex-d. NOR EVQ 55 UD (direct entry 2 x /4 1 x /4 Ex-d.00 NOR EVQ 85 UD (direct entry 2 x /4-14 mm Ex-d 1 x /4 Ex-d. NOR EVQ 85 UD (direct entry 2 x /4 1 x /4 Ex-d.8 NOR EVQ 55 XM (indirect entry 2 x M25 x mm Ex-e 1 x M25 Ex-e. NOR EVQ 55 XM (indirect entry 2 x M25 x x M25 Ex-e.80 NOR EVQ 85 XM (indirect entry 2 x M25 x mm Ex-e 1 x M25 Ex-e 1.0 NOR EVQ 85 XM (indirect entry 2 x M25 x x M25 Ex-e 1. NOR Accessories EVQ 55, EVQ 85 Type Content Application Order No. G. EV 200 Wire Guard EVQ 55 NOR G. EV 500 Wire Guard EVQ 85 NOR PC. EV 200 External reflector EVI 200 / EVQ 55 NOR PC. EV 500 External reflector EVI 500 / EVQ 85 NOR KEY, EV Lamp key EV... NOR CEV/AB Eye bolt EV... NOR AS. EV Ceiling bracket, adjustable EV... NOR SPU. EV Wall mounting barcket EV... NOR BC. EV Pole mounting bracket EV... NOR SP. EV 200 Wall mounting bracket EVQ 55 NOR SP. EV 500 Wall mounting bracket EVQ 85 NOR Metal cable glands see page 8... Dimensions drawing Polar curve kg EVQ 55 UD Ø 245 entry optional entry, on request 400 Dimensions for Accessories see page 5.1 Ø Ø 0 EVQ 55 XM EVQ 85 UD EVQ 85 XM 4 Ø 0 Polar curve EVQ 55/85 without external reflector 0 0 C 0 C l/cd/klm Polar curve EVQ 55/85 with external reflector 0 0 C 0 C C O O P E R C R O U S E - H I N D S G M B H 4.1 l/cd/klm Dimensions in mm

20 I Ex-Pendant light fitting I EV ZM EV ZM Technical data EVM EVS EVH Marking to 4//EC II 2 G Ex de IIC T (new standard applied for) II 2 D Ex td A21 IP66 T C EC-Type Examination Certificate LOM 02 ATEX 20 X IECEx Certificate of Conformity IECEx BKI 0.001X Marking acc. to IECEx Ex de IIC T Ex td A21 IP6 T Permissible ambient temperature -20 C to +55 C -45 C to +55 C (option) Rated voltage 2 V AC 2) Rated current Frequency 50 Hz 2) Power factor cos ϕ > 0.85 Circuit electromagnetic circuit Connecting terminals x (2 x 2.5 mm 2 ); PE extern. 2 x 6 mm 2 Insulation class I Lamp cap E 2 (EV ), E 40 (EV ) Light efficiency in operation 6 % Degree of protection accd. EN 52 IP6 Cable glands/gland plates/enclosure drilling 2 x M25 threads (Ex-e), one plugged Dimensions (L x W x H) 480 mm x Ø 245 mm (EV ZM) 5 mm x Ø 0 mm (EV ZM Weight see ordering information Type of mounting ceiling mounting Enclosure material light alloy Enclosure colour grey Protective cover/protective bowl borosilicate glass see ordering details 2) other voltages or frequencies on request Additional lamp data Lamp Luminous Power Type Temperature class II 2 G Max. surface temp. II 2 D flux ) Tambient 40 C Tambient > 40 C Tambient 40 C Tambient > 40 C High pressure mercury vapor HME 60 lm 5 W EVM 5 ZM T4 T4 T5ºC T1ºC High pressure mercury vapor HME 0 lm 250 W EVM 250 ZM T4 T T5ºC T140 C High pressure sodium lamp HSE 50 lm 0 W EVS 0 ZM T5 T4 T5ºC T0ºC High pressure sodium lamp HSE lm 150 W EVS 150 ZM T5 T4 TºC T5ºC High pressure sodium lamp HSE lm 250 W EVS 250 ZM T4 T4 T5ºC T1ºC High pressure Metal Halide HIE 1000 lm 250 W EVH 250 ZM T4 T T5ºC T140ºC ) depends on used lamps 4.20 C O O P E R C R O U S E - H I N D S G M B H

21 I Ex-Pendant light fitting I 1 2 Ordering details EV ZM EV ZM Type Lamp Rated current Cable gland Ex-e Weight Order No. for cable Ø kg (T ambient -20 C to +55 C) EVM 5 ZM HME 5W 1. A -14 mm 14.1 NOR EVM 5 ZM HME 5W 1. A 14.0 NOR EVM 250 ZM HME 250W 2. A -14 mm 22.4 NOR EVM 250 ZM HME 250W 2. A 22.5 NOR EVS 0 ZM HSE 0W 0.5 A -14 mm 14.1 NOR EVS 0 ZM HSE 0W 0.5 A 14.0 NOR EVS 150 ZM HSE 150W 0.6 A -14 mm 22.4 NOR EVS 150 ZM HSE 150W 0.6 A 22.4 NOR EVS 250 ZM HSE 250W 1.0 A -14 mm 22.4 NOR EVS 250 ZM HSE 250W 1.0 A 22.4 NOR EVH 250 ZM HIT 250W 1.80 A -14 mm 22.4 NOR EVH 250 ZM HIT 250W 1.80 A 22.4 NOR (T ambient -45 C to +55 C) EVM 5 ZM HME 5 W 0.6 A 14.0 NOR EVM 250 ZM HME 250 W 0.6 A 22.4 NOR EVS 0 ZM HSE 0 W 1.0 A 14.0 NOR EVS 150 ZM HSE 150 W 1.0 A 22.4 NOR EVS 250 ZM HSE 250 W 1.80 A 22.4 NOR EVH 250 ZM HIT 250 W 1.80 A 22.4 NOR Lamps and fixing accessories are not included C O O P E R C R O U S E - H I N D S G M B H 4.21

22 I Ex-Pendant light fitting I EV ZM EV ZM Accessories EVM, EVS, EVH Type Content Application Order No. REP 200 Space glass EV NOR REP 500 Spare glass EV NOR G. EV 200 Wire guard EV NOR G. EV 500 Wire guard EV NOR PC. EV 200 External reflector EV NOR PC. EV 500 External reflector EV NOR KEY, EV Lamp key EV.. NOR CEV/AB Eye bolt EV.. NOR AS. EV Ceiling bracket, adjustable EV.. NOR SPU. EV Ø mm Wall mounting barcket EV.. NOR BC. EV Pole mounting bracket EV.. NOR SP. EV 200 Wall mounting bracket EV NOR SP. EV 500 Wall mounting bracket EV NOR Metal cable glands see page 8... Dimensions drawing entry Ø 245 Ø EV ZM EV ZM BC. EV /4 ø ø SP.EV 200/ /4 KEY.EV CEV/AB AS.EV Polar curve EV 200/500 without external reflector 0 0 Polar curve EV 200/500 with external reflector C 0 C l/cd/klm 5 45 C l/cd/klm Dimensions in mm 4.22 C O O P E R C R O U S E - H I N D S G M B H

23 C O O P E R C R O U S E - H I N D S G M B H 4.2

24 E X - P E N D A N T L I G H T F I T T I N G S dhls for high pressure discharge lamps Metal version for Zone 1/2 The explosion-protected pendant light fittings dhls for high pressure discharge lamps are in accordance to the ATEX-Directive 4//EG. They are certified for use in the Zones 1 and 2. The housing is made of a light alloy with a powdered coating. The pressed-in thread-ring for the flameproof thread gap is made of brass. This provides for an easy lamp replacement even after a longer operating periods. The pendant light fitting is designed for outdoor use. Due to the high safety standard it has more than proven its reliability in chemical factories and offshore platforms for illuminating large areas and selective large objects. The light fitting is fitted with a dome-shaped glass cover and can also be fitted with an external reflector. Cost-effective illumination of large objects For use in chemical factories and offshore platforms Robust light alloy housing with a powdered coating Easy lamp replacement even after extended time of operation Or with an external reflector 4.24

25 I Ex-Pendant light fittings I 1 2 Technical data dhls dhls dhls Marking to 4//EC II 2 G Ex de IIC T EC-Type Examination Certificate DMT 0 ATEX E 0 IECEx Certificate of Conformity IECEx BKI Marking accd. to IECEx Ex de IIC T Permissable ambient temperature 20 C to +50 C / 20 C to +55 C (250 W) 45 C to +55 C (option) Rated voltage 2 V AC Rated current Frequency 50 Hz Power factor cos ϕ 0.5 ind. / 0. comp. Circuit inductive circuit / compensated circuit Connecting terminals L + N + PE; 2 x 2.5 mm 2 Insulation class I Lamp/Illuminant high pressure mercury vapour lamp HME 250 W / 400 W high pressure sodium lamp HSE 250 W / 400 W Lamp cap E 40 acc. IEC 28 Light efficiency in operation % 55 % (AR) 2) Degree of protection accd. EN 52 IP65 Cable glands/gland plates/enclosure drilling 1 x M25 x 1.5 for cables from Ø 8-1 mm 1 x M25 x 1.5 with blanking plug Dimensions (L x W x H) 50 x Ø 20 mm (without compensation box) 80 x Ø 20 mm (with compensation box) Weight approx. kg approx. kg with compensation box Enclosure material light alloy with powder coating, grey Protective cover/protective bowl borosilicate glass see table 2) AR = external reflector C O O P E R C R O U S E - H I N D S G M B H 4.25

26 I Ex-Pendant light fittings I dhls Ordering details Type Lamp Rated luminous flux 2) Rated current Power factor cos Order No. dhls W HME 0 lm 2.2 A 0,5 ind. CGS 8688 P W HME 0 lm 1.1 A 0, comp. CGS 8688 P W HSE lm.0 A 0,5 ind. CGS 8688 P W HSE lm 1.5 A 0, comp. CGS 8688 P01 dhls W HME lm.25 A 0,5 ind. CGS 888 P W HME lm 2.5 A 0, comp. CGS 888 P W HSE 4000 lm 4.4 A 0,5 ind. CGS 888 P W HSE 4000 lm.0 A 0, comp. CGS 888 P01 Lamps and fixing accessories are not included 2) depends on used lamps Accessories dhls dhls Type Content Order No. EB Eye bolt, M ( pcs.) galvanized GHG 6 1 R000 L 218 Mounting bracket for inductive version GHG 6 11 R0001 L 4 Mounting bracket for compensated version GHG 6 11 R0002 AR External reflector, metal, white powder coated CGS 22 P00 Dimensions drawing ring bolts Ø 20 Ø 500 dhls ind Ø 20 Ø 500 dhls komp M, 18 deep Compensation box Polar curve with external reflector dhls C 0 C l/cd/klm Polar curve without external reflector dhls X X0 L 218 L C 0 C l/cd/klm Dimensions in mm 4.26 C O O P E R C R O U S E - H I N D S G M B H

27 C O O P E R C R O U S E - H I N D S G M B H 4.2

28 E X - F L O O D L I G H T S FZD 04 and FZD EN for High Pressure Discharge Lamps Metal Design for Zone 1/ 21 The explosion-protected floodlight FZD 04 for high-pressure discharge lamps meets the requirements of the ATEX directive 4//EC. The modular floodlight FZD 04 comprises an Ex-e housing for the starter and a separate mounted Ex-e enclosure with ballast and the p.f. correction capacitor. The floodlight enclosure made of high grade aluminium and stainless steel components is a light weight, which can be installed easily by a single electrician without need of a crane or other heavers. All main components are certified separa tely as components. The flameproof lamp module can easily be separated from the housing once a screw has been loosened. Two sealing systems of degree of protection IP66 ensure permanently protected Ex-d contacts. There is no need to switch off the mains voltage to separate the module from the luminaire. This means that a simple lamp change and easy cleaning of the lamp modules possible, even outside the potentially explosive atmos - pheres. Optionally, the module can be used with narrow-angle and wide-angle reflectors even retrospectively and without any compli - cated installation. By simply and quickly exchanging the lampmodule, changing the lamp is not a problem, even in extreme weather or climate conditions. The FZD EN combines the easy lamp replacement with a compact enclosure. All components are protected in one Ex-d enclosure. All advantages of easy re-lamping and easy maintenance are same with FZD 04. Simple lamp change by the Ex-d lamp module Modular Ex-e/Ex-d housing High degree of protection IP66 Internal wide-angle- or, optionally, narrow-angle reflector For low ambient temperatures of up to -45 C 4.28

29 I Ex-Floodlight I 1 2 Technical data Ballast enclosure Floodlight enclosure FZD 04 Marking to 4//EC II 2 G Ex demq IIC T II 2 D Ex td A21 IP66 T EC-Type Examination Certificate PTB 02 ATEX 58 IECEx Certificate of Conformity IECEx BKI Marking accd. to IECEx Ex de IIC T or T4 Ex td A21 IP66 T C Permissible ambient temperature -45 C to + C Rated voltage 2 V AC 2) Rated current Frequency 50 Hz 2) Power factor cos ϕ > 0. Circuit compensated circuit Insulation class I Degree of protection accd. EN 52 IP66 Lamp module Floodlight enclosure Type of protection Lamp module: Ex d IIC Floodlight enclosure: Ex em IIC Connecting terminals 2 x (2 x 2.5 mm 2 ) mm 2 PE Lamp/Illuminant High pressure sodium lamp tubular (HST) Metal halide lamp tubular (HIT) Lamp cap E 40 acc. EN Light efficiency in operation 66 % Cable glands/gland plates/enclosure drilling 1 x M25 x 1.5 with plastic cable glands Ex-e M25 for non-armoured cable Ø 8-1 mm ) option with metal thread M20, without cable gland Weight Lamp module lamp: approx..6 kg Floodlight enclosure: approx. 4. kg Enclosure earth 2.5 mm 2 PE Ballast enclosure Type of protection Ex emq IIC Connecting terminals x (2 x 4 mm 2 ) + 4 mm 2 PE Cable glands/gland plates/enclosure drilling x M25 x 1.5, 2 x M25 plastic cable grand Ex-e for cable Ø 8-1 mm M25 for one plugged 4) Weight approx. kg (polyester fiberglass) approx. kg (stainless steel) Enclosure material Polyester reinforced fiber glass, or stainless steel see table 2) other voltages or frequencies on request ) Connection to the ballast enclosure 4) One to connect to the floodlight enclosure, the others for the mains connection 5) mounting position ± 15, see instruction Additional lamp data Lamp Rated Temperature class II 2 G Max. surface temp. II 2 D current Tamb. +40 C Tamb. +50 C Tamb. + C Tamb. +40 C Tamb. +50 C Tamb. + C HST / HIT 150 W 0,8 A T4 T4 T T 0 ºC T 1 ºC T 140 ºC HST / HIT 250 W 1, A T4 5) /T T T 1 ºC 5) /T 150 ºC T 1 ºC HST / HIT 400 W 2,1 A T T 180 ºC C O O P E R C R O U S E - H I N D S G M B H 4.2

30 I Ex-Floodlight I Floodlight enclosure Ballast enclosure Ordering details FZD 04 Lamp Rated luminous flux Light distribution Order No. Ballast enclosure made of polyester with cable gland for mains connection 250 W HIT/HST 0 lm / lm narrow beam NOR W HIT/HST 0 lm / lm wide beam NOR W HIT 5000 lm narrow beam NOR W HIT 5000 lm wide beam NOR W HST lm narrow beam NOR W HST lm wide beam NOR Ballast enclosure made of stainless steel with cable gland for mains connection 250 W HIT/HST 0 lm / lm narrow beam NOR W HIT/HST 0 lm / lm wide beam NOR W HIT 5000 lm narrow beam NOR W HIT 5000 lm wide beam NOR W HST lm narrow beam NOR W HST lm wide beam NOR Ballast enclosure made of polyester without cablegland for mains connection 250 W HIT/HST 0 lm / lm narrow beam NOR W HIT/HST 0 lm / lm wide beam NOR W HIT 5000 lm narrow beam NOR W HIT 5000 lm wide beam NOR W HST lm narrow beam NOR W HST lm wide beam NOR Ballast enclosure made of steel without cablegland for mains connection 250 W HIT/HST 0 lm / lm narrow beam NOR W HIT/HST 0 lm / lm wide beam NOR W HIT 5000 lm narrow beam NOR W HIT 5000 lm wide beam NOR W HST lm narrow beam NOR W HST lm wide beam NOR depends on used lamps 4. C O O P E R C R O U S E - H I N D S G M B H

31 I Ex-Floodlight I 1 2 Technical data FZD EN FZD EN Marking to 4//EC II 2 G Ex demq IIC T II 2 D IP66 T EC-Type Examination Certificate PTB 02 ATEX 58 IECEx Certificate of Conformity IECEx BKI Marking accd. to IECEx Ex de IIC T or T4 Ex td A21 IP66 T C Permissible ambient temperature -45 C to +50 C Rated voltage 2 V AC 2) Rated current 250 W: 1. A / 400 W: 2.1 A Frequency 50 Hz 2) Power factor cos ϕ > 0. Circuit compensated circuit Insulation class I Lamp/Illuminant High pressure sodium lamp - tubular (HST) Metal halide lamp - tubular (HIT) 250 W or 400 W Lamp cap E 40 acc. EN Light efficiency in operation 66 % Degree of protection accd. EN 52 IP66 Cable glands/gland plates/enclosure drilling 2 x M25 x 1.5 with plastic cable gland Ex-e M25 for non-armoured cable Ø 8-1 mm, other plugged; option: with metal thread M20, without cable gland Dimensions (L x W x H) 5 x x 50 mm Weight 28 kg (enclosure); kg lamp module Enclosure material light alloy Enclosure colour grey Protective cover/protective bowl die-cast light alloy Options tempered safety glass Enclosure earth 2.5 mm 2 PE see table 2) other voltages or frequencies on request Additional lamp data Lamp Temperature class II 2 G Max. surface temp. II 2 D Ordering details Tambient up to +40 C Tambient up to +50 C Tambient up to +40 C Tambient up to +50 C HST / HIT 250 W T4 5) /T T T 1 ºC 5) /T 150 ºC T 1 ºC HST / HIT 400 W T T 180 ºC 5) mounting position ± 15, see instruction Lamp Rated luminous flux ) Reflector Order No. FZD EN 250 W HIT / HST 0 lm / lm wide-angle W HIT 5000 lm wide-angle W HST lm wide-angle W HIT / HST 0 lm / lm narrow-angle W HIT 5000 lm narrow-angle W HST lm narrow-angle ) depends on lamp Delivery without lamp, incl. mounting bracket C O O P E R C R O U S E - H I N D S G M B H 4.1

32 I Ex-Floodlight I Lamp module Slip fitter Mounting plate Swivel bracket Accessories FZD 04 Type Content FZD 04 FZD EN Order No. Lamp module Lamp module 250 W/400 W complete with internal reflector, narrow-angle reflector X X wide-angle reflector X X Slip fitter fitter for pole 1 1 /4 mounting complete with fixing screws X NOR Slip fitter fitter for pole 2 mounting complete with fixing screws X NOR Swivel bracket Ajustable hinge for wall/pole mounting X NOR Mounting plate Stainless steel plate for wall or pole installation (using pipe clamps, not incl.) X NOR Pipe clamp 1 1 /4 pipe clamp (1 pcs) galvanized Ø 8-42 mm 2 X Pipe clamp 1 1 /4 pipe clamp (1 pcs) stainless steel Ø 8-42 mm 2 X Pipe clamp 1 1 /2 pipe clamp (1 pcs) galvanized Ø 4-51 mm 2 X Pipe clamp 2 pipe clamp (1 pcs) galvanized Ø 56 - mm 2 X Lamps and fixing accessories are not included Metal cable glands see page 8... Polar curve Polar curve FZD... with wide beam reflector Polar curve FZD... with narrow beam reflector C 0 C l/cd/klm C 0 C l/cd/klm 4.2 C O O P E R C R O U S E - H I N D S G M B H

33 I Ex-Floodlight I 1 2 Swivel bracket Mounting plate Slip fitter Lamp module Dimensions drawing 250/400 W: Ø X X Ø Ballast enclosure: plastic X FZD /400 W X Swivel bracket 8, 6,6 0 Ballast enclosure: stainless steel 1, Ø Slip fitter , Mounting plate C O O P E R C R O U S E - H I N D S G M B H 4. Dimensions in mm

34 E X - F L O O D L I G H T PX 04 for high pressure discharge lamps Metal version for Zone 1/21 The explosion-protected floodlight PX 04 for high pressure discharge and halogen lamps are in accordance to the ATEX-Directive 4//EG. They are certified for use in the Zones 1, 21, 2 and 22. The light fitting housing is made of copper-free aluminium, the glass cover of a mechanical and thermal resistant borosilicate glass. All external screws are made of stainless steel. The electrical components are thermically separated in their own compartment and have a separate Ex-e maintenance-friendly connection compartment. With the adjustable mounting frame an optimum on light guidance is reached. Due to the robust architecture it has more than proven its reliability in chemical factories and offshore platforms for illuminating large areas and selective large objects. For environmental temperatures of up to + 55 C Degree of protection IP6 Robust light alloy housing Captive screws made of stainless steel Large Ex-e connection compartment Easy to maintain Easy to install 4.4

35 I Ex-Floodlight I 1 2 Technical data PX 04 PX Marking to 4//EC II 2 G Ex de IIB T II 2 D Ex td A21 IP6 T C EC-Type Examination Certificate BVS 0 ATEX E 50 X IECEx Certificate of Conformity IECEx BKI Marking accd. to IECEx Ex de IIB T2-T4 Ex td A21 IP66 T85 C - 2 C Permissible ambient temperature -20 C to +55 C (-55 C up to +55 C optional) Rated voltage with control gear 2 V AC 2) without control gear 250 V AC Rated current 4 5 Frequency 50 Hz 2) Power factor cos ϕ > 0.85 Circuit compensated circuit Connecting terminals L1, N: 2 x 4 mm2; PE: 2 X 6 mm 2 Insulation class Lamp/Illuminant Lamp cap E 40 (E2 for 0 W HIT and HST, 150 HIT) acc. IEC 28 Light efficiency in operation 62 % Degree of protection accd. EN 52 Cable glands/gland plates/enclosure drilling Dimensions (L x W x H) Weight Type of mounting Enclosure material Enclosure colour Protective cover/protective bowl Reflector I IP6 Indirect entries: 2 x M25 x 1.5 with or without cablegrands (see table), one plugged 546 x 44 x 6 mm (with control gear) 546 x 44 x 40 mm (without control gear) approx. 1 kg (with control gear) approx. 2 kg (without control gear) mounting bracket light alloy grey borosilicate glass Enclosure earth 2 x 6 mm 2 see table 2) other voltages or frequencies on request ) depends on lamp Additional lamp data polished aluminium reflector 6 8 Type Rated luminous Temperature class II 2 G Max. surface temp. II 2 D flux ) Tambient +40 C Tambient +55 C Tambient +40 C Tambient +55 C HS_ - 0 W 00 lm T4 T4 T85 ºC T0 ºC HI_ - 0 W 60 lm T4 T4 T ºC T5 ºC HS_ W 1000 lm T4 T4 T5 ºC T1 ºC HI_ W lm T4 T4 T5 ºC T0 ºC HS_ W 00 lm T4 T T1 ºC T145 ºC HI_ W lm T4 T T1 ºC T145 ºC HME W 0 lm T T T150 ºC T165 ºC HST W lm T T T15 ºC T1 ºC HIT W 5000 lm T T T10 ºC T185 ºC HME W lm T T2 T186 ºC T201 ºC HST - 0 W 000 lm T T2 T15 ºC T2 ºC IQT W 000 lm T T2 T185 ºC T200 ºC C O O P E R C R O U S E - H I N D S G M B H 4.5

36 I Ex-Floodlight I PX 04 Ordering details Type Reflector Lamp Lamp Rated current Ex-e metal cable Order No. gland for cable PX 04 narrow beam High pressure sodium lamp HST 0 W.1 A Ø - 14 mm NOR PX 04 narrow beam High pressure sodium lamp HST 0 W.1 A NOR PX 04 wide beam High pressure sodium lamp HST 0 W.1 A Ø - 14 mm NOR PX 04 wide beam High pressure sodium lamp HST 0 W.1 A NOR PX 0440S narrow beam High pressure sodium lamp HS_ 400 W 2.02 A Ø - 14 mm NOR PX 0440S narrow beam High pressure sodium lamp HS_ 400 W 2.02 A NOR PX 0440S wide beam High pressure sodium lamp HS_ 400 W 2.02 A Ø - 14 mm NOR PX 0440S wide beam High pressure sodium lamp HS_ 400 W 2.02 A NOR PX 0440H narrow beam High pressure metal halide HI_ 400 W 2) 1.8 A Ø - 14 mm NOR PX 0440H narrow beam High pressure metal halide HI_ 400 W 2) 1.8 A NOR PX 0440H wide beam High pressure metal halide HI_ 400 W 2) 1.8 A Ø - 14 mm NOR PX 0440H wide beam High pressure metal halide HI_ 400 W 2) 1.8 A NOR PX 0440M narrow beam Mercury vapor HME 400 W NOR PX 0425 narrow beam H.P. sodium lamp/metal halide HS_ / HI_250 W 1.5 A Ø - 14 mm NOR PX 0425 narrow beam H.P. sodium lamp/metal halide HS_ / HI_250 W 1.5 A NOR PX 0425 wide beam H.P. sodium lamp/metal halide HS_ / HI_250 W 1.5 A Ø - 14 mm NOR PX 0425 wide beam H.P. sodium lamp/metal halide HS_ / HI_250 W 1.5 A NOR PX 0425M narrow beam Mercury vapor HME 250 W NOR PX 0415 narrow beam H.P. sodium lamp/metal halide HS_ / HI_150 W 1.05 A Ø - 14 mm NOR PX 0415 narrow beam H.P. sodium lamp/metal halide HS_ / HI_150 W 1.05 A NOR PX 0415 wide beam H.P. sodium lamp/metal halide HS_ / HI_150 W 1.05 A Ø - 14 mm NOR PX 0415 wide beam H.P. sodium lamp/metal halide HS_ / HI_150 W 1.05 A NOR PX 040 narrow beam High pressure sodium lamp HS_ 0 W 0.5 A Ø - 14 mm NOR PX 040 narrow beam High pressure sodium lamp HS_ 0 W 0.5 A NOR PX 0405 narrow beam Halogen IQT 500 W 2.1 A Ø - 14 mm NOR PX 0405 narrow beam Halogen IQT 500 W 2.1 A NOR PX 0405 wide beam Halogen IQT 500 W 2.1 A Ø - 14 mm NOR PX 0405 wide beam Halogen IQT 500 W 2.1 A NOR Valid for lamps HI_ 400 W (4.2 A) 2) Valid for lamps HI_ 400 W (.5 A) Lamps and fixing accessories are not included Accessories PX 04 Type Content Order No. SB Pipe fixing Ø 48 mm to Ø 64 mm NOR ATP Portable stand, painted steel NOR PAH Horizontal steel shade, painted steel NOR PAV Vertical steel shade, painted steel NOR Metal cable glands see page C O O P E R C R O U S E - H I N D S G M B H

37 I Ex-Floodlight I 1 2 Dimensions drawing PX PX 04 without ballast for QT- and HME-SB-Lamps 5 Ø 14 Ø 26 Ø PX 04 with ballast for all high pressure discharge lamps M25 PX optional entry, on request entry Polar curve PX 04 with narrow beam reflector Polar curve PX 04 with wide beam reflector C 0 C l/cd/klm C 0 C l/cd/klm C O O P E R C R O U S E - H I N D S G M B H 4. Dimensions in mm

38 E X - F L O O D L I G H T dtls for high pressure discharge lamps Metal version for Zone 1/2 The explosion-protected floodlight dtls for high pressure discharge lamps is in accordance to the ATEX-Directive 4//EG. They are certified for use in the Zones 1 and 2. The housing is made of a light alloy with a powdered coating. The pressed-in thread-ring for the flameproof thread gap is made of brass. This provides for an easy lamp replacement even after a longer operating periods. The floodlight is designed for outdoor use. Due to the high safety standard it has more than proven its reliability in chemical factories and offshore platforms for illuminating large areas and selective large objects. The vaporized reflectors are designed for various angles of dispersion. Cost-effective illumination of large objects For use in chemical factories and offshore platforms Robust light alloy housing with a powdered coating Easy lamp replacement even after extended time of operation Vaporized reflector for various angles of dispersion 4.8

39 I Ex-Floodlights I 1 2 Technical data dtls dtls / dtls 8500 Marking to 4//EC II 2 G Ex de IIC T/T4 EC-Type Examination Certificate DMT 0 ATEX E 0 IECEx Certificate of Conformity IECEx BKI Marking accd. to IECEx Ex de IIC T4 (0 W) Ex de IIC T (250 W) Permissable ambient temperature 20 C to +50 C Permissable ambient temperature (option) 45 C to +50 C (option) Rated voltage 2 V AC Rated current 2) Frequency 50 Hz Power factor cos ϕ 2) Circuit inductive circuit / compensated circuit Connecting terminals L + N + PE; 2 x 2.5 mm 2 Insulation class I Lamp/Illuminant high pressure metal-halide lamp HIT-DE high pressure sodium vapour lamp HST-DE Lamp cap Fc2 / Rx s Rated luminous flux HIT-DE 250 W: 0 lm HST-DE 250 W: lm HST-DE 0 W: 6800 lm Light efficiency in operation 2 % 46 % with diffuser lens Degree of protection accd. EN 52 IP65 Cable glands/gland plates/enclosure drilling 1 x M25 x 1.5 for cables from Ø 8-1 mm 1 x M25 x 1.5 with blanking plug Weight approx. 25 kg approx. 2 kg with compensation box Enclosure material light alloy with powder coating, grey Enclosure colour grey Protective cover/protective bowl borosilicate glass Other voltages, frequencies or entries on request 2) see ordering details Ordering details Type Lamp Rated current Power factor cos ϕ Temperature Order No. class dtls S with diffusser lens 250 W HIT/HST.0 A 0.4 ind. T CGS 8588 P W HIT/HST 1.5 A 0. comp. T CGS 8588 P01 dtls P 250 W HIT/HST.0 A 0.4 ind. T CGS 8588 P0002 with parabolic-reflector 250 W HIT/HST 1.5 A 0. comp. T CGS 8588 P02 dtls 8500 P with reflector 0 W HST 0.5 A 0.5 comp. T4 CGS 8588 P000 Lamps and fixing accessories are not included C O O P E R C R O U S E - H I N D S G M B H 4.

40 I Ex-Floodlights I dtls Accessories dtls Type Application Order No. EB Eye bolt, M ( St.) galvanized GHG 6 1 R000 L 218 Mounting bracket, for inductive version GHG 6 11 R0001 L 4 Mounting bracket, for compensated version GHG 6 11 R0002 Dimensions drawing 2 ring bolts Compensation box M, 18 deep Polar curve with parabolic reflector dtls C 0 C Polar curve with diffuser lens dtls l/cd/klm Ø 20 dtls ind. Ø 20 dtls komp X L 218 L 4 Dimensions in mm C 0 C l/cd/klm 4 54 X C O O P E R C R O U S E - H I N D S G M B H

41 C O O P E R C R O U S E - H I N D S G M B H 4.41

42 E m e r g e n c y U n i t Explosion-protected, modular GHG 664 emergency lighting supply unit with explosion- protected dtls 8500 P floodlight for high- pressure lamp Safety for escape routes and evacuation equipment in the event of an emergency and power failure In the event of a power failure, the new explosion-protected GHG 664 emergency pack enables the battery-supported operation of a 0 W sodium high-pressure lamp for the duration of 1.5 hours. When used in combination with the powerful explosion-protected dtls 8500 P floodlight, escape routes and evacuation equipment (life boats, life rafts, abseiling equipment or rescue cushions, etc.) can be safely illuminated, even from larger distances. They have been designed especially for offshore use on platforms and ships. Both the GHG 664 emergency pack and the dtls 8500 P floodlight are in explosionprotected design in accordance with the ATEX Directive 4//EC and have been approved for use in Zones 1 and 2. The emergency pack GHG 664 features a flameproof enclosure for the electronic components and a flanged-on box in the type of protection increased safety that accommodates the battery and the connection terminals. The dtls 8500 P floodlight, which is mounted separately from the emergency pack, features a robust enclosure made of powder-coated aluminium with a borosilicate glass lens, a parabolic reflector for the 0 W sodium vapour high-pressure lamp. Thus, for example, with a luminous spot height of m, it is possible to illuminate an area measuring 15 x 15 m with 1 lx. Suited for use on offshore platforms and ships Safe light for evacuation equipment in hazardous areas Emergency lighting duration of 1.5 hours in the event of a power failure Large Ex-e connection box to facilitate installation Maintenance-friendly due to simple replacement of lamps and batteries Continuous and standby light with switching-off device (only V) 4.42

43 I Emergency Unit I 1 2 Technical data dtls 8500 GHG 664 GHG 664 Marking to 4//EC II 2 G Ex de IIC T6 EC-Type Examination Certificate PTB 0 ATEX 2002 X Permissable ambient temperature 5 C to +40 C Rated voltage V AC / Option: 0 V AC Rated frequency 50 - Hz Output voltage 2 V AC Power consumption (charging operation) < 40 VA Nominal output max. 80 VA Circuit electronic converter Insulation class I Battery 2 x V, Ah Rated operating duration (emergency operation) 1.5 h Charging duration (> % C) < 24 h Degree of protection acc. to EN 52 IP66 Weight approx. 48 kg (incl. battery) Enclosure material light alloy with powder coating, grey Floodlight dtls 8500 P Marking to 4//EC II 2 G Ex de IIC T4 EC-Type Examination Certificate DMT 0 ATEX E 0 Permissable ambient temperature 20 C to +50 C Rated voltage V, 50 - Hz Connecting terminals L + N + PE; max. 2.5 mm 2 Insulation class I Lamp/Illuminant High pressure sodium lamp HST-DE 0 W Lamp cap RXs Rated luminous flux 6800 lm Light efficiency in operation 2 % Degree of protection acc. to EN 52 IP65 Cable glands 1 x M25 x 1.5 for cables from Ø 8-1 mm 1 x M25 x 1.5 with blanking plug Weight approx. 18 kg Enclosure material light alloy with powder coating, grey Light transmitting cover Borosilicate glass depends on lamp 8 Ordering details Type Application Order No. Emergency Unit GHG V AC incl. battery plus dtls 8500 P GHG R0001 Emergency Unit GHG V AC incl. battery plus dtls 8500 P GHG R0002 Lamps and fixing accessories are not included Accessories Mounting bracket L218 Type Content Application Order No. L218 Mounting bracket dtls 8500 P GHG 6 11 R0001 C O O P E R C R O U S E - H I N D S G M B H 4.4

44 I Emergency Unit I GHG 664 dtls 8500 Dimension drawing Polar curve 2 ring bolts Ø8 X dtls 8500 P GHG 664 Polar curve dtls 8500 P C l/cd/klm Dimensions in mm Ø Ø14,50 X 61 28, X X0 50 X L C O O P E R C R O U S E - H I N D S G M B H

45 C O O P E R C R O U S E - H I N D S G M B H 4.45

46 E X - V E S S E L L I G H T F I T T I N G KFL with halogen reflector lamp or W LED Metal version for Zone 1 This explosion-protected tank light fitting KFL is in accordance to the ATEX-Directive 4//EG. It has been certified for use in the Zones 1, 21 2 and 22 areas. This powerful tank light fitting is equipped with a high output LED lamp V/ W or a high-voltage halogen reflector lamp 2 V/50 W and is especially for use as an inspection lighting at inspection windows of mixers from size DN40 up to DN200. The housing is made of a copper-free aluminium. The aluminium collar has a PTFE (Teflon) coating, additionally it has a viton sealant. Equipped with a special transporting handle the KFL LED can also be used as a maintenance light fixture. With the light fitting holder PR it can be mounted on inspection windows according to DIN 280. Compact architecture Connection ready for 2 V AC With halogen reflector incandescent lamp with 50 W or high-power LED W High illumination Generously dimensioned terminal compartment Mounting onto inspection windows according to DIN

47 I Ex-Tank inspection luminaires KFL 50 I 1 2 Technical data Type KFL W LED Type KFL KFL 50 KFL W LED Marking to 4//EC II 2 G Ex de IIC T II 2 G Ex de IIC T6 (new standard applied for) II 2 D Ex td A21 IP66 T140 C II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate LOM 02 ATEX 205 IECEx Certificate of Conformity IECEx BKI Marking acc. to IECEx Ex de IIC T Ex td A21 IP6 T140 C Permissable ambient temperature 20 C to +55 C 20 C to +55 C Permissable ambient temperature (option) 50 C to +55 C 50 C to +40 C Rated voltage 2 V, 50/ Hz V, 50/ Hz Rated current 0.25 A A Power consumption 50 VA VA Connecting terminals 2 x 2.5 mm 2 ; PE internal and external 6 mm 2 Insulation class I Lamp/Illuminant 50 W high voltage (halogen lamp type W PHILIPS MASTER LED Lamp cap GZ Degree of protection accd. EN 52 Cable glands/gland plates/enclosure drilling Weight Enclosure material Enclosure colour Protective cover/protective bowl Options Ordering details Sylvania included, others on request) IP66 2 x M25 x 1.5, one plugged kg light alloy with powder coating grey borosilicate glass 20 W lamp (T4 / T0 C) Type Entry Cable entry Exe Blanking Order No. (T ambient -20 C to +55 C) thread for cable Ø plug KFL 50 W M25-14 mm Ex-e 1 x M25 NOR KFL 50 W M25 1 x M25 NOR KFL 50 W TIM 2 V - V M25-14 mm Ex-e 1 x M25 NOR KFL 50 W TIM 2 V - V M25 1 x M25 NOR KFL LED M25 1 x M25 NOR (T ambient -50 C to +55 C) KFL 50 W M25 1 x M25 NOR KFL 50 W TIM 2 V - V M25 1 x M25 NOR (T ambient -50 C to +40 C) KFL LED M25 1 x M25 NOR Supply with support device as standard (lamp holder PR). Metal cable glands see page 8... Accessories KFL 50 Type Content Application Order No. Lamp Halogene reflector lamp 2 V/50 W KFL 50 NOR Lamp Halogene reflector lamp V/50 W KFL 50 TIM NOR AT transport grip KFL.. NOR PAD antiglare shield KFL.. NOR PI mounting legs out of center KFL.. NOR PI mounting legs bended KFL.. NOR LED-lamp Philips Master LED W KFL W LED NOR C O O P E R C R O U S E - H I N D S S A

48 I Ex-Tank inspection luminaires KFL 50 I Typ KFL Dimensions drawing 12 5 DIN 40/50 DIN Light fixing facility PR DIN 0 DIN 5 Windows, nominal width KFL 50 TIM 180 Polar curve KFL Polar curve KFL W C Dimensions in mm l/cd C l/cd 4.48 C O O P E R C R O U S E - H I N D S G M B H

49 C O O P E R C R O U S E - H I N D S G M B H 4.4

50 E X - P E N D A N T L I G H T F I T T I N G NVMV for high pressure discharge lamps of up to 400 W Metal version for Zone 2/22 The explosion-protected light fittings of the NVMV series are in accordance to the ATEX- Directive 4//EG. They have been built and tested according to the European Standard for Gas-Ex-Areas of Zone 2 classification as well as to EN for use in Dust-Ex-Areas of Zone 22. The light fittings series NVMV with the small housing is designed for lamps with a rating of 0 W up to 150 W. The large housing is designed for lamps with a rating of 250 W up to 400 W. The transparent part consists of a temperature stable, impact resistant glass globe that refracts the light and which is protected with a safetyguard. The modular architecture allows for a quick and cost-effective installation of the light fittings. For pole mounting, a thread of /4 BSP is integrated in the light fitting. Apart from ceiling mounting, there are versions available for pole mounting (25 angle) and wall mounting. A particularly durable sealing system for use under extreme climatic conditions brings additional reliability. The restricted breathing version allows a high illumination combined with a high temperature classification. Ideal for installation at low or medium heights, for wall, ceiling or pole mounting Compact and light-weight Degree of protection IP66/6 High corrosion resistance Restricted breathing version for temperature classes up to T4 Environmental temperatures up to +55 C 4.50

51 I Ex-Pendant light fitting I 1 2 Technical data NVMV NVMV NVMV NVMV CHAMP for high pressure discharge lamps up to 400 W Marking to 4//EC II G Ex nr IIC T II D Ex td A22 IP6X T Type Examination Certificate applied for Permissable ambient temperature 20 C up to +55 C Rated voltage 240 V/50 Hz (other voltage and frequencies on request) Power factor cos > 0. Connecting terminals L, N and PE; max. 2 x 2.5 mm 2 Insulation class I Lamp cap E 2 (0 W HSE, 5 W HME, 150 HIE) E 40 (150 HSE W HSE/HME) Light efficiency in operation 4 % ( W) 8 % ( W) Degree of protection accd. EN 52 IP6/66 Cable glands/gland plates)enclosure drilling Drilling 4 x M25 x 1.5 with blanking plug Dimensions (L x W x H) 420 x 24 x 18 mm (0-150 W) 555 x 24 x 18 mm ( W) Weight see ordering details Enclosure material light alloy with epoxy powder coating Enclosure colour grey Protective cover/protective bowl borosilicate glass Additional lamp data Lamp Power Rated luminous Temperature class II G Surface temperature II D flux 2) -20 C up to +55 C -20 C up to +55 C NVMV (smalling housing) HSE ) 0 W 5.0 lm T4 1 C HSE ) 150 W lm T 15 C HME 4) 5 W 6.0 lm T 15 C HIE 5) 0 W 5.0 lm T4 1 C HIE 5) 150 W.500 lm T 15 C NVMV (large housing) HSE ) 250 W lm T 15 C HSE ) 400 W lm T 15 C HME 4) 250 W lm T 15 C HIE 5) 250 W lm T 15 C HIE 5) 400 W lm T2 2 C see table 2) depents on used lamps 8 ) HSE = High pressure sodium lamp 4) HME = High pressure mercury vapor 5) HIE = High pressure metal halide lamp C O O P E R C R O U S E - H I N D S G M B H 4.51

52 I Ex-Pendant light fitting I NVMV NVMV NVMV Ordering details Type Mounting HSE HME HIE Weight Order No. (approx. kg) NVMV... (small enclosure) S2MC06P000 Ceiling 0 W S2MC156P000 Ceiling 150 W H2MC6P000 Ceiling 5 W M2MC06P000 Ceiling 0 W M2MC156P000 Ceiling 150 W S2MW06P000 Wall 0 W S2MW156P000 Wall 150 W H2MW6P000 Wall 5 W M2MW06P000 Wall 0 W M2MW156P000 Wall 150 W S4BJ06P000 Thread* 1 1 /4, BSP 0 W S4BJ156P000 Thread* 1 1 /4, BSP 150 W H4BJ6P000 Thread* 1 1 /4, BSP 5 W M4BJ06P000 Thread* 1 1 /4, BSP 0 W M4BJ156P000 Thread* 1 1 /4, BSP 150 W NVMV... (large enclosure) S2MC256PL00 Ceiling 250 W S2MC406PL00 Ceiling 400 W H2MC256PL00 Ceiling 250 W M2MC256PL00 Ceiling 250 W M2MC406PL00 Ceiling 400 W S2MW256PL00 Wall 250 W S2MW406PL00 Wall 400 W H2MW256PL00 Wall 250 W M2MW256PL00 Wall 250 W M2MW406PL00 Wall 400 W S4BJ256PL00 Pole 250 W S4BJ406PL00 Pole 400 W H4BJ256PL00 Pole 250 W M4BJ256PL00 Pole 250 W M4BJ406PL00 Pole 400 W *Thread for 1 1 /4 BSP pole mounting Lamps and fixing accessories are not included Accessories NVMV CHAMP Type Content Order No. RD 0 External reflector ( W) RD 4 External reflector ( W) Metal cable glands see page C O O P E R C R O U S E - H I N D S G M B H

53 I Ex-Pendant light fitting I 1 2 Dimensions drawing NVMV NVMV NVMV 24 Ø Ø Thread 1 1 /4 BSP Pole mounting 25 5 Ceiling mounting Wall mounting 24 Ø254 24, Ø 8 4, , NVMV Pole mounting Thread 1 1 /4 BSP NVMV Ceiling mounting NVMV Wall mounting 8 Polar 0 curve NVMV W 0 (without external reflector) Polar 0 curve NVMV W 0 (with external reflector) Polar 0 curve NVMV W0 (without external reflector) C 0 C l/cd/klm Polar 0 curve NVMV W0 (with external reflector) C 0 C l/cd/klm C l/cd/klm C l/cd/klm Dimensions in mm C O O P E R C R O U S E - H I N D S G M B H 4.5

54 E X - F L O O D L I G H T NFMV and NSSFMV for high pressure discharge lamps Metal version for Zone 2/22 The floodlights NFMV and NSSFMV in accordance to the ATEX-Directive 4//EG. They have been built and tested according to the European Standard for Gas-Ex-Areas of Zone 2 classification as well as for use in Dust-Ex-Areas of Zone 22. The light fitting series NFMV and NSSFMV for lamps with a rating of 250 W up to 400 W and have a high quality built-in reflector. The enclosure of the NFMV is made of light alloy with epoxy powder coating. The NSSFMV has a stainless steel enclosure. The transparent part consists of a temperature stable, impact resistant glass. The modular architecture allows for a quick and cost-effective installation of the light fittings. Apart from the direct mounting per swivel bracket there is also a pole version available. A particularly durable sealing system for use under extreme climatic conditions brings additional reliability. The restricted breathing version allows a high illumination combined with a high temperature classification. Rotate und swivel light fitting housing, also for pole mounting Ideal for illumination of large areas and selective individual objects Degree of protection IP66 High corrosion resistance Restricted breathing version For environmental temperatures up to +55 C 4.54

55 I Ex-Floodlight I 1 2 Technical data NFMV NFMV Marking to 4//EC II G Ex nr II T II Ex td A22 IP66 T Type Examination Certificate PTB 0 ATEX 2000 Permissable ambient temperature 20 C to +55 C Rated voltage 240 V (other voltage on request) Frequency 50 Hz (other frequencies on request) Power factor cos > 0. Connecting terminals L, N and PE; 2 x 4 mm 2 Insulation class I Lamp cap E 40 acc. IEC 28 Light efficiency in operation 45 % Degree of protection accd. EN 52 IP66 Cable glands/gland plates/enclosure drilling 2 x M20 x 1.5; 1 plugged Dimensions (L x W x H) 6 x 4 x 15 mm Weight Enclosure material light alloy with epoxy powder coating Enclosure colour grey Protective cover/protective bowl borosilicate glass see table Ordering details Type Lamps Rated luminous Ta Temperature Max. surface Weightt Order No. HSE HIE flux 2) class temperature (approx. kg) NFMV... HSE 150 W 150 W lm 55 C T4 5 C 15.5 NOR HSE 250 W 250 W lm 50 C T 150 C 16. NOR HSE 400 W 400 W 4000 lm 45 C T 1 C 18.6 NOR HIE 250 W 250 W 1000 lm 50 C T 150 C 16. NOR HIE 400 W 400 W 000 lm 45 C T 1 C 18.6 NOR ) depends on used lamps Lamps and fixing accessories are not included Accessories 8 NFMV... Type Qty. Order No. Slipfitter adapter 2 for pole mounting Metal cable glands see page 8... C O O P E R C R O U S E - H I N D S G M B H 4.55

56 I Ex-Floodlight I NFMV Dimensions drawing Ø 1/2-1 UNC 254 M20 ISO M20x1.5 Ø NFMV Swivel bracket - Slip fitter adaptor 2 Polar 0 curve 0 NFMV Dimensions in mm +1 I: C 0 C l/cd/klm 4.56 C O O P E R C R O U S E - H I N D S G M B H

57 I Ex-Floodlight I 1 2 Technical data NSSFMV NSSFMV Stainless Steel Version Marking to 4//EC II G Ex nr II T/T4 II D Ex td A22 IP66 T Declaration of conformity PTB 0 ATEX 20 Permissable ambient temperature 20 C to max. +55 C Rated voltage 2 V 2) Frequency 50 Hz 2) Power factor cos > 0. Connecting terminals L, N and PE; 2 x 2.5 mm 2 Insulation class I Lamp cap E 40 acc. IEC 28 Light efficiency in operation 68 % Degree of protection accd. EN 52 IP66 Cable glands/gland plates/enclosure drilling 2 x M25 x 1.5, 1 plugged 2) Dimensions (L x W x H) 56 x 52 x 15.5 mm Weight Type of mounting mounting bracket, stainless steel 16 Enclosure material stainless steel 16 Enclosure colour natural Protective cover/protective bowl borosilicate glass see table 2) other voltages, frequencies and cable glands on request Ordering details Type Lamps Rated luminous TA Temp. Max. surface Weight Order No. HSE HIE flux ) class temperature (approx. kg) NSSFMV SY W lm +40 C/+55 C T4 1 C 16. CCL0005 SY W lm +50 C T 180 C 1.5 CCL0021 SY W 1000 lm +50 C T 180 C 1.5 CCL0021 SY W 4000 lm T 15 C 18.6 on request SY W 000 lm T 15 C 18.6 on request ) depend on oused lamps 8 4) at ta max. +40 C Lamps and fixing accessories are not included Accessories NSSFMV Type Order No. Slipfitter adapter Metal cable glands see page 8... C O O P E R C R O U S E - H I N D S G M B H 4.5

58 I Ex-Floodlight I NSSFMV Dimensions drawing Polar curve Ø 1/2-1 UNC M20 ISO NSSFMV Polar 0 curve 0 NSSFMV C 0 C l/cd/klm Dimensions in mm I: Ø. mounting holes 4.58 C O O P E R C R O U S E - H I N D S G M B H

59 C O O P E R C R O U S E - H I N D S G M B H 4.5

60 A C C E S S O R I E S Fittings and Ex- Floodlights Lamps for Ex- Pendant Light Fittings and Ex- Floodlights Lamps for Use in Ex-Pendant Light Fittings and Floodlights Lamps for Ex-Pendant Light Fittings and Floodlights are normally not part of the delivery. The lamps are specified by IEC Standards and described by different Lamp Designation Systems. In Europe a standardized system was developed and introduced by the German ZVEI. This system (LBS) allows easily to name a lamp independent from the different manufacturers. In the following table all lamps used in the Ex-pendant light fittings and floodlight are shown with the relevant short description and LBS-name. Spare Parts As well as the above, there is also a large amount of spare parts available for maintenance and repair work. If required, please contact us, you will find that we will be more than pleased to help you. We must point your attention to the fact that repair work done on explosive-protected products must be carried out with original spare parts only! If this is not the case and third-party parts are used, the Certification and Approval for the product will be forfitted and a possible reduction of the explosion-protection may be achieved. Repair Service Of course Cooper Crouse-Hinds GmbH upholds its own Repair Department where customer repairs are carried out. Our qualified and schooled personnel carry out repairs and overhauling using original spare parts, quickly and efficiently. This service also includes the end quality testing needed for explosion protected products. With this service you have an assured safety as do all overhauled Ex-Lamps and products by Cooper Crouse-Hinds GmbH. 4.

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22) .3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information

CEAG Products Main Catalogue Part 1 Chapter 4. Ex-Ceiling, pendant light fittings and floodlights. EATON 1.4.1

CEAG Products Main Catalogue Part 1 Chapter 4. Ex-Ceiling, pendant light fittings and floodlights.  EATON 1.4.1 CEAG Products Main Catalogue Part 1 Chapter Ex-Ceiling, pendant light fittings and floodlights www.crouse-hinds.de EATON 1..1 2 1..2 EATON www.crouse-hinds.de Ex-Ceiling, pendant light fittings and floodlights

More information

4.35. Accessories for Ex-Ceiling light fitting AB 80. Guard GAB 80 NOR Accessories for Ex-Pendant light fitting AB 50

4.35. Accessories for Ex-Ceiling light fitting AB 80. Guard GAB 80 NOR Accessories for Ex-Pendant light fitting AB 50 EV... 0-0 ZM EVI 00 UD AB 0 IU AB 0. Accessories for Ex-Ceiling light fitting AB 0 Guard GAB 0 NOR 000 00 0 Accessories for Ex-Pendant light fitting AB 0 Ceiling bracket with screws / AS.EV/AB NOR 000

More information

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure .13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in

More information

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments .13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications

More information

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive

More information

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22 .1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk

More information

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22) .1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Explosion-protected recessed ceiling LED-light and fluorescent light fittings .7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX

More information

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND

More information

2.20. EX-LIGHT FITTING ellk MAIN FEATURES EX-LIGHT FITTING ellk EX-POLE MOUNTED LIGHT FITTING ellm

2.20. EX-LIGHT FITTING ellk MAIN FEATURES EX-LIGHT FITTING ellk EX-POLE MOUNTED LIGHT FITTING ellm 1 E X - F L U O R E S C E N T L I G H T F I T T I N G S 2 3 6 EX-LIGHT FITTING ellk 2... MAIN FEATURES EX-LIGHT FITTING ellk 2... 2.20 2.12 7 EX-POLE MOUNTED LIGHT FITTING ellm 2... EX-EMERGENCY LIGHT

More information

EX-FLUORESCENT LIGHT FITTINGS

EX-FLUORESCENT LIGHT FITTINGS EX-FLUORESCENT LIGHT FITTINGS Cooper Crouse-Hinds 00 - all rights reserved EX-LIGHT FITTING ellk... MAIN FEATURES.0 EX-LIGHT FITTING ellk... EX-POLE MOUNTED LIGHT FITTING ellm....0. EX-EMERGENCY LIGHT

More information

CEAG Products Main Catalogue Part 1 Chapter 2. Ex-Light fittings. EATON 1.2.1

CEAG Products Main Catalogue Part 1 Chapter 2. Ex-Light fittings.  EATON 1.2.1 CEAG Products Main Catalogue Part 1 Chapter Ex-Light fittings www.crouse-hinds.de EATON 1..1 1.. EATON www.crouse-hinds.de Ex-Light fittings Table of contents.1 Information on Ex-linear light fittings

More information

IEC METALLIC PRODUCTS

IEC METALLIC PRODUCTS ELECTRCL EQUPMENT FOR EXPLOSVE ENVRONMENTS EC METLLC PRODUCTS C T L O G U E 00/07 T B L E O F C O N T E N T S L G H T F T T N G S S G N L N D ES C P E S G N L U M N R E S P E N D N T L G H T F T T N G

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

I Ex d/e Switch- and Control-Equipment I

I Ex d/e Switch- and Control-Equipment I I Ex d/e Switch- and Control-Equipment I Customised enclosure, covered by Type Examination Certificates, can be individually combined from CEAG s numerous built-in components. Furthermore control units

More information

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE STARK-CLE EM STARK-CLE EM-SO Ø315

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE STARK-CLE EM STARK-CLE EM-SO Ø315 D Product description Ideal for ceiling-mounted and wallmounted luminaires Based on annular and compact fluorescent lamps Efficiency of the module up to 127 lm/w SO version is compatible with SWITCH Sensor

More information

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar Outdoor Distribution Cabinets 14.0 Chapter-Content Page 14.0 Surface Mounted Boxes 2 14.1 Flush Mounted Boxes 9 14.2 Distribution Pillar 10 23 14 http://www.krone-gmbh.at - Page 1 14.0 Surface Mounted

More information

EX-CONTROL AND DISTRIBUTION SYSTEMS

EX-CONTROL AND DISTRIBUTION SYSTEMS EX-CONTROL AND DISTRIBUTION SYSTEMS Cooper Crouse-Hinds 00 - all rights reserved EX-DISTRIBUTION IN PLASTIC DESIGN. EX-DISTRIBUTION IN STAINLESS STEEL EX-D BUILT-IN COMPONENTS.. 9 EX-E EMPTY ENCLOSURES

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category

More information

LED light engines LED linear / area. Module CLE Quadrant G3 ADV Modules CLE ADVANCED

LED light engines LED linear / area. Module CLE Quadrant G3 ADV Modules CLE ADVANCED Module CLE Quadrant G3 ADV Modules CLE ADVANCED Product description Ideal for round shaped and flat ceiling and pendant luminaires THE solution to realise XXL luminaires For uniform illumination of prestige

More information

PHASED OUT. LED light engines LED linear / area. Module CLE Quadrant G2 ADV Modules CLE ADVANCED

PHASED OUT. LED light engines LED linear / area. Module CLE Quadrant G2 ADV Modules CLE ADVANCED Product description Ideal for round shaped and flat ceiling and pendant luminaires THE solution to realise XXL luminaires For uniform illumination of prestige areas or rooms designed to impress High Output

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8. TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire

More information

Installation Equipment

Installation Equipment Installation Switches made of Moulded Plastic 800 8 Junction Boxes made of Polyester Resin, with Sheath Terminals 80 8 made of Polyester Resin, with... 8 Sheath Terminals 88 8 Terminal Boxes made of Polyester

More information

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems

More information

LED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE

LED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE w LED light engine / OLED Module DLE G4 ADV Modules DLE Product description For downlights Luminous flux up to 3,71 lm at tp = 65 C High efficacy up to 185 lm/w for the LED module at tp = 25 C High system

More information

LED light engine / OLED LED compact. Uengine DLE G2 integrated ADV

LED light engine / OLED LED compact. Uengine DLE G2 integrated ADV Uengine DLE G2 integrated ADV uengine DLE Product description Module with integrated electronics For downlights Light engine operating with 23 V AC Luminous flux range from 1,24 2,43 lm High system efficacy

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-3 umodule SPOT PHASED OUT 46,5 39,5 35,5 NTC NTC LED + LED 8,5 4,5 8,5

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-3 umodule SPOT PHASED OUT 46,5 39,5 35,5 NTC NTC LED + LED 8,5 4,5 8,5 Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Lifetime up to 5, hours Compact design Excellent thermal management 1 NTC for temperature control

More information

PHASED OUT. LED light engine / OLED LED compact. Module SLE G4 6mm R SNC, SLE G4 10mm R SNC China domestic Modules SLE ESSENCE

PHASED OUT. LED light engine / OLED LED compact. Module SLE G4 6mm R SNC, SLE G4 10mm R SNC China domestic Modules SLE ESSENCE w LED light engine / OLED Product description For general lighting application Typ. luminous flux category: 3/6/8/1,2 lm High efficacy up to 113 lm/w for the LED module at tp = 25 C Small LES (light emitting

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

LED light engines LED compact. Module DLE G4 ADV Modules DLE

LED light engines LED compact. Module DLE G4 ADV Modules DLE w LED light engines Module DLE G4 ADV Modules DLE Product description For downlights Luminous flux up to 6,35 lm at tp = 65 C High efficacy up to 185 lm/w for the LED module at tp = 25 C High system efficacy

More information

Tunable White LED compact

Tunable White LED compact Module TW DLE G2 60mm 3000lm 927-965 DLE modules Product description module for Downlights with adjustable colour temperature from 2,700 to 6,500 K at constant luminous flux High colour rendering index

More information

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Technical Information TI 271F/00/en Operating Instructions 017182-1000 Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Transmitters for capacitance probes Application The electronic inserts

More information

Field IT 50T Series Transmitters

Field IT 50T Series Transmitters Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing

More information

LED light engine / OLED LED compact. Umodule STARK DLE CLASSIC STARK DLE 82,8 54,4. Ordering data

LED light engine / OLED LED compact. Umodule STARK DLE CLASSIC STARK DLE 82,8 54,4. Ordering data Product description Downlights High-flux LED module Low tolerances for colour temperatures (MacAdams 4) Compact design Excellent thermal management 1 NTC for temperature control High-power LED module in

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 8x0 H ADV D50

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 8x0 H ADV D50 w LED light engine / OLED Product description For spotlights and downlights Housing with Snap-On feature for easy reflector mounting Luminous flux up to 2,92 lm at tp = 65 C High efficacy up to 147 lm/w

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK QLE G2 CLASSIC STARK QLE

PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK QLE G2 CLASSIC STARK QLE Product description Ideal for linear and panel lights Luminous flux range from 1,19 1,53 lm LED system solution with outstanding system efficiency up to 125 lm/w, consisting of squared LED modules and

More information

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-3 EM umodule SPOT PHASED OUT NTC NTC LED + LED + LED EM LED EM

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-3 EM umodule SPOT PHASED OUT NTC NTC LED + LED + LED EM LED EM Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Lifetime up to 5, hours Compact design Excellent thermal management NTC for temperature control High-power

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes with thin-film sensor element Probes Probe guides Measuring tubes Examples of Application Flow measurements also in hazardous locations Ex zone 0 or zone 1 in clean rooms in air conditioning and ventilating

More information

LED light engines LED compact. Module SLE G7 ADV Modules SLE ADVANCED

LED light engines LED compact. Module SLE G7 ADV Modules SLE ADVANCED w LED light engines Module SLE G7 ADV Modules SLE ADVANCED Product description For spotlights and downlights For operating with SELV Driver Luminous flux up to 6,18 lm at tp = 65 C High efficacy up to

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Z7A. Load cells. Special features. Data sheet. Wiring code

Z7A. Load cells. Special features. Data sheet. Wiring code Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust

More information

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal

More information

MR medium rating busbar

MR medium rating busbar technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC umodule SLE ESSENCE

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC umodule SLE ESSENCE w LED light engine / OLED Product description For general lighting application Typ. luminous flux category: 2,/3, lm High efficacy up to 145 lm/w for the LED module at tp = 25 C Small LES (light emitting

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 9x0 H EXC D50

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 9x0 H EXC D50 w LED light engine / OLED Product description For spotlights and downlights Housing with Snap-On feature for easy reflector mounting Luminous flux up to 2,51 lm at tp = 65 C High efficacy up to 124 lm/w

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 17mm TINGE R SNC umodule SLE ESSENCE

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 17mm TINGE R SNC umodule SLE ESSENCE w LED light engine / OLED Product description For general lighting application Typ. luminous flux category: 2,/3, lm High efficacy up to 18 lm/w for the LED module at tp = 25 C Small LES diameter (light

More information

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF

More information

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-3 EM umodule SPOT PHASED OUT 39,5 35,5 NTC NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-3 EM umodule SPOT PHASED OUT 39,5 35,5 NTC NTC Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Lifetime up to 5, hours Compact design Excellent thermal management NTC for temperature control High-power

More information

LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC China domestic umodule SLE ESSENCE

LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC China domestic umodule SLE ESSENCE w LED light engine / OLED Umodule SLE G4 17mm R SNC China domestic umodule SLE ESSENCE Product description For general lighting application Typ. luminous flux category: 2,/3, lm High efficacy up to 12

More information

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18 erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

CLUSTERLITE CONTENTS MEGAMAN

CLUSTERLITE CONTENTS MEGAMAN CONTENTS Specifications for... 2.1 Maximum Temperature Declaration... 2.3 Lumen Maintenance Curve... 2.4 Vs. Temperature... 2.6 Run-up Time... 2.8 Specifications for Power Supply... 2.1 Line Drawings for

More information

LARVIK Slim. Flood Lighthing W BRILLIANT VERSATILITY. Meet any light demands, from to lumens

LARVIK Slim. Flood Lighthing W BRILLIANT VERSATILITY. Meet any light demands, from to lumens Up to LARVIK Slim 5 Flood Lighthing 10-280W BRILLIANT VERSATILITY Meet any light demands, from 1.000 to 31.000 lumens Many Lenses and eratures available Very Slim and Compact IP67 housing 1 Up to 5 LARVIK

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

LED light engine / OLED LED linear / area

LED light engine / OLED LED linear / area LED light engine / OLED Module CLE G1 25mm ADV IND Modules CLE ADVANCED Product description LED modules for diffuse highbay applications Luminous flux: 26, lm per module Efficacy of the module up to 155

More information

LED light engine / OLED LED compact. Uready2apply DLA G1 SNC China domestic

LED light engine / OLED LED compact. Uready2apply DLA G1 SNC China domestic Uready2apply DLA G1 SNC China domestic uready2apply DLA Product description Downlight module suitable for direct installation in ceilings (ready2apply) Module with integrated electronics and heatsink Light

More information

Surface-mounting thermostats Series ATH

Surface-mounting thermostats Series ATH JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS Online data sheet WL80-S30 W80 WL80-S30 W80 A B C D E F Illustration may differ Ordering information Type Part no. WL80-S30 607484 Included in delivery: P0 (), BEF-W80 () Other models and accessories www.sick.com/w80

More information

YEARS hrs L W. Flood Lighthing

YEARS hrs L W. Flood Lighthing ARVIK SLIM Flood Lighthing 5 YEARS 50.000 hrs L50 10-280W Wide range of luminaires truly built for outdoors Smart optics minimize the number needed Up to 60% Energy-Savings Meet your needs from 1.000 to

More information

LED modules LED linear / area

LED modules LED linear / area Module LLE G4 16mm 65lm ADV Module LLE advanced Product description Ideal for compact linear luminaires designs Homogenous illumination thanks to small package distance SELV module the single module has

More information

LED light engines LED linear / area

LED light engines LED linear / area Module LLE G4 16mm 125lm ADV Module LLE ADVANCED Product description Ideal for compact linear luminaires designs Homogenous illumination thanks to small package distance SELV module the single module has

More information

PHASED OUT. LED light engine / OLED LED compact. Module DLE G3 ADV Modules DLE

PHASED OUT. LED light engine / OLED LED compact. Module DLE G3 ADV Modules DLE w LED light engine / OLED Product description For downlights Luminous flux up to 3,68 lm at tp = 65 C High efficacy up to 165 lm/w for the LED module at tp = 25 C High system efficacy up to 147 lm/w at

More information

LED light engine / OLED LED compact. Module DLE G3 ADV Modules DLE

LED light engine / OLED LED compact. Module DLE G3 ADV Modules DLE w LED light engine / OLED Module DLE G3 ADV Modules DLE Product description For downlights Luminous flux up to 3,68 lm at tp = 65 C High efficacy up to 165 lm/w for the LED module at tp = 25 C High system

More information

SANMUR CONTROLS PVT. LTD.

SANMUR CONTROLS PVT. LTD. Decide with confidence NMUR CONTROLS NMUR CONTROLS PVT. LTD. An ISO 900:008 Certified Company The name NMUR has been synonymous with reliability and quality in terms of products, services and systems integration.

More information

Application PN 16 / 40 DN Product features. Compact overall height Body shape gives optimum flow characteristic

Application PN 16 / 40 DN Product features. Compact overall height Body shape gives optimum flow characteristic pplication Control of gases, vapours and liquids. The modular concept of valve, multi spring actuator and digital FOXBORO/Eckardt positioner Type SRD 992 facililates trouble free expansion to allow for

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-2 umodule SPOT C.PHASED NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-2 umodule SPOT C.PHASED NTC Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board

More information

Thermometers. Applications

Thermometers. Applications 92 Temperature Thermometers Thermometers On the next pages you will find a broad range of thermometers with fixed probes or exchangeable probes with rigid probes or probes with cable and hand grip. The

More information

industry hall : highbay luminaire NJ700 LED Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 07/2013

industry hall : highbay luminaire NJ700 LED Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 07/2013 industry hall Customer : Processed by : Siteco Light Consulting Project description: spatial geometry (L*W*H): 54,00m*21,00m*9m reflection values (C*W*F): 70*50*20 maintenance factor: 0,67 user surface

More information

PHASED OUT. LED light engines LED linear / area. Module QLE G1 471x462mm 5000lm SNC Modules QLE ESSENCE

PHASED OUT. LED light engines LED linear / area. Module QLE G1 471x462mm 5000lm SNC Modules QLE ESSENCE Product description Luminous flux: 5, lm per module Square module one module per luminaire nonselv (HV) and SELV (LV) variants High colour rendering index CRI 8 Small colour tolerance (MacAdam 4) Efficacy

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation TF / TF -Ex Field mounted temperature transmitter, Profibus PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN According to PROCESS FIELD BUS 0Input Resistance thermometer (,, -wire method)

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-2 umodule SPOT C.PHASED NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-2 umodule SPOT C.PHASED NTC Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board

More information

ATEX/IECEx RTD temperature probe

ATEX/IECEx RTD temperature probe Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE Module STARK QLE G3 SELECT Modules QLE EXCITE Product description Ideal for linear and panel lights Luminous flux range from 1,9 1,62 lm LED system solution with outstanding system efficacy up to 137 lm/w,

More information

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

THM80X Series  Feature Application. Temperature & Humidity / Flow Measuring Specialist THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,

More information

Exchangeable measuring insets SensyTemp TSA101

Exchangeable measuring insets SensyTemp TSA101 Contents Data Sheet Exchangeable measuring insets SensyTemp TSA101 for resistance thermometers and thermocouples Structure of electrical thermometers - Exchangeability during operation based on modular

More information

MODEL NAME : LLDMWW0-15K*0*A

MODEL NAME : LLDMWW0-15K*0*A Eagle Eye (Outdoor LED Module) Application Note MODEL NAME : LLDMWW0-15K*0*A RoHS Compliant HALOGEN FREE (30)-4022 1 / 16 CONTENTS 1. Product Description 3/16 2. Specifications 2.1. Chromaticity Bins for

More information