CT30 Barcode Scanner U s e r Manual

Size: px
Start display at page:

Download "CT30 Barcode Scanner U s e r Manual"

Transcription

1 CT30 Barcode Scanner U s e r Manual

2 IMPORTANT NOTICE Safety Precaution * DO NOT disassemble the scanner, or place foreign matter into the scanner cause a short circuit or circuit damage. * DO NOT expose the scanner or battery to any flammable sources. Maintenances Precaution * Use a clean cloth to wipe dust off the body of the scanner. * If you find the scanner abnormal, write down the specific scenario and consult the maintenance person. Enviromental Paramenter Operating Temp. 0 to 50 ºC / 32 to 122 ºF Storage Temp. 0 to 50 ºC / 32 to 122 ºF Operating Humidity 20-85% (non-condensing) Storage Humidity 20-85% (non-condensing) 2

3 Contents IMPORTANT NOTICE Safety Precaution Maintenances Precaution Enviromental Paramenter...2 Contents...3 Overview o f CT30 Barcode Scanner Features of t h e Scanner...5 Appearance...5 Introduction of KeyFunction....6 Specifications Correct Aiming...7 Incorrect Aiming QUICK START E n t e r t h e Setting Mode E x i t t h e Setting Mode with S a v e E x i t t h e Setting Mode without S a v e Restore Factory Defaults Check Software V e r s i o n S a v e Custom Settings...11 Chapter 1 Features a n d Basic Setups Battery Mounting t h e battery (charging) Howt o operate CT20 Barcode Scanner AutoP o w e r Off T r a n s m i t Buffer Inventory Mode LED Indicator Beeper Beeper V o l u m e Scan Modes Manual Mode Continuous Mode AutoP o w e r OffMode Auto-induction Mode Symbologies Supported USBW i r e d DataTransmission...25 Chapter 2 Howt o Connect with BT Select Output Interface BT S P P Mode BT HIDMode

4 4

5 Overview of CT30 Barcode Scanner CT30 Bluetooth wireless barcode scanner,which is developed by our company, is a c o s t effective,small size,light weight, fits ergonomically,easy to carry,1d bar code scanner. CT30 bar code scan parts using the1d bar code scanning solutions of r e d light bar code scanning patent technology of CILICO, U s i n g 630nm r e d light indicates a CCD imaging technology a n d intelligent image recognition system, integrating high-performance processor a n d decoded board, with ability tor e a d fast decoding a n d high precision, high resistance to environmental interference. I t caneasily r e a d thebar code on thepaper, merchandise,etc...the barcode scanning distance ismuch improved thansimilar products, it scanning very fast, reading bar code highly exactly. CT30 Bluetooth barcode scanner has internal long distance wireless Bluetooth,and it can compatible with laptops, desktops or other real-time data transmission Bluetooth devices. The power source of it is a pair of replaceable A A batteries, When y o u ' r e outside of B T, the 256K memory can storetens of thousands of scanned information toensure thatyour data is security Features o f the Scanner *Smallsize, portable. *Supports three scan modes, including Continuous Mode, Manual Mode, Auto-off Mode *Supports most popular barcode symbologies *User feedback v i a L E D indicator a n d beeper *Thevoice volume of scan barcode successfully could change via setting barcode *Built-in KB F l a s h memory can store u p t o thousand scan barcodes. *Provides 2 KB memory for reserve buffer while Bluetooth connection interrupt, can store u p t o scan barcodes. * Supports BT SPP. * Supports BT HID. * Programmable parameters include data output format, editing format, symbologies, etc. 5

6 Appearance Introduction of Key Function 6

7 Note:P r e s s P o w e r button t u r n on/off T u r n off t h e scanner,press t h e mutifunction with P o w e r button t o clear t h e lastest pair information of record i n t h e CT30. P r e s s t h e multifunction t o sendt h e recorded bar code. Aftert u r n off t h e scanner,press t h e scan button with P o w e r button t o clear t h e recording bar code andt u r n ont h e scanner. Specifications Radio range 10m visual range Bluetooth Bluetooth class 2. 0 virsion+edr Sensor 2500 pixels Communication mode SPP,HID Light source Redlight LED 630± 20nm Decode capacity Codabar, Code 11, Code 93, MSI,Code128, UCC/EAN-128, Code 39, EAN-8, EAN-13,UPC-A,ISBN,Industrial 25,Industrial 25 Standard 25,2 / 5 Matrix Resolution 5 m il Scan distance 6~30cm Scan speed 200times/second indication Beeper,indicator Print contrast ratio 30% Cylinder Horizontal scan Diameter35mm Operating Temp. 0 to 5 0 º C / 3 2 to 122 ºF Storage Temp. 0 to 5 0 º C / 3 2 to 122 ºF Operating Humidity 20-85% (non-condensing) Storage Humidity 20-85% (non-condensing) Correct A i m i n g 7

8 Incorrect Aiming QUICK START The setting o f t h e CT30 Barcode Scanner can b e changed b y reading t h e setup barcodes contained i n t h i s manual. This section describes t h e procedure o f setting t h e CT30 Barcode Scanner b y reading t h e setup barcodes a n d provides some example for demonstration. Steps Action Feedback if Successful 1 Turn on CT30 Barcode Scanner... It will response with a long beep(high t o n e ), i t ' s L E D shows red a n d w i t h I n t m t twinkle. N o t e : How t h e CT30 Barcode Scanner establishes a connection w i t h computer o r other compatible device, please refer to Chapter 2. 2 Enter the Setting Mode... TheCT30 Barcode Scanner will response three beeps (tone descending from high t o l o w ), and i t s LED indicator will flashing purple. E n t e r S e t u p 3 Reada Setup barcode The CT30 Barcode Scanner will response three beeps (tone ascending from l o w t o high), a n d i t s LED indicator will flashing purple. For Example: Enable Codabar 4 Exit the Setting Mode... The CT30 Barcode Scanner will response three beeps (tone descending from high t o l o w ), and i t s L E D indicator 8

9 will not flashing purple and power off. E x i t with S a v e N o t e : When a n y setup error occurs, t h e CT30 Barcode Scanner will respond w i t h a l o n g beep (low tone), a n d i t s L E D indicator w i l l flashing purple. Steps of Setup: Enter Setup Details (eg: Enable/Disable a Barcode) Exit Setup Enter the Setting Mode F o r t h e scanner t o enter t h e setting mode, y o u must have i t read t h e "Enter Setup" barcode, w h i c h will b e located a t t h e bottom o f almost every page o f t h i s manual. TheCT30 Barcode Scanner will respond with three beeps (tone descending from high to l o w ), a n d i t s L E D indicator becomes purple a n d g o o f f quickly after reading t h e barcode. Enter Setup F o r setting scanner parameters, see "Reada Setup Barcode" below. Exit the Setting Mode with Save F o r t h e scanner t o e x i t t h e setting mode, y o u must h a v e i t read t h e "Exitw i t h Save" barcode, w h i c h will b e located a t t h e bottom o f almost every page o f t h i s manual. Just like reading the "Enter Setup" barcode, the scanner will respond with three beeps (tone ascending f r o m l o w t o high) after reading t h e barcode. 9

10 Exit with Save Exit the Setting Mode without Save I f y o u want t o e x i t t h e setting mode without saving a n y changes, y o u must h a v e t h e scanner read t h e "Exitwithout Save" barcode. Just like reading the "Enter Setup" barcode, the scanner will respond with three beeps (tone ascending f r o m l o w t o high) after reading t h e barcode. Exit without Save Restore Factory Defaults "RestoreFactory Defaults" is a special barcode. The CT30 Barcode Scanner will respond w i t h a short beep (high tone) after reading t h i s barcode. At t h i s t i m e, t h e scanner system could restore factory defaults, a n d n o need t o read "Exitw i t h Save" barcode again. The Scanner defaults enable HID, PIN defaults RestoreFactory Defaults N o t e : Most of setting mode have restore factory defaults selection. The factory default value for each setting i s indicated b y a n asterisk "*". Y o u could u s e t h i s barcode a t t h e following status: 1 The scanner can n o t w o r k. F o r example, i t can not read barcodes. 2 Y o u forget t h e settings y o u d i d t o t h e scanner before, a n d y o u don't want t o b e affected b y t h e settings when y o u u s e t h e scanner. 3 After u s i n g a function w h i c h i s n o t b e u s e d usually i n t h e scanner. 10

11 Check Software V e r s i o n I f y o u want t o know t h e software version o f CT30, should read t h e Enter Setup a n d Output Software V e r s i o n barcode: Enter Setup Output S o f t w a r e V e r s i o n Checking t h e software version i s done a t t h e enter setup mode, so after output t h e software version, need to read Exit without Save barcode. Exit without Save Save Custom Settings 1. You may change factory defaults, and customize some functions suitable for your own applications when you use CT30, you must read the Enter Setup Function barcode you want t o customize Save CustomSettings Exit w i t h Save barcodes. Enter Setup Save CustomSettings RestoreCustomsSettings 1 1

12 Exit with Save 2. If you want to restore to custom settings after resetting the barcode scanner, just need to read Enter Setup Restore Custom Settings Exit with Save barcodes as above. 12

13 Chapter 1 Features a n d Basic Setups This chapter will introduce t h e features a n d usage o f t h e CT30 barcode scanner. Contents 1.1Battery Mounting t h e battery(charging) Howt o operate CT30 Barcode Scanner AutoP o w e r Off T r a n s m i t Buffer LED Indicator Beeper Beeper V o l u m e Scan Modes Manual Mode Continuous Mode AutoP o w e r OffMode Auto-induction Mode Symbologies Supported USBW i r e d DataTransmission

14 1.1Battery The scanner is powered by two AA batteries or AAA alkaline batteries. The batteries can support the scanner work continuous for 60 hours, or read barcodes (read an EAN-13 barcode per 5s ) Mounting t h e battery (charging) 1) Hold t h e scanner face d o w n i n o n e hand. 2 )Press the back case and push like picture. 3 ) p u t i n t h e batteries. 4 )close t h e b a c k case H o w t o operate CT30 Barcode Scanner T u r n on t h e scanner Press t h e Power key for about 2 seconds. The scanner will respond w i t h a l o n g beep (high tone), a n d i t s L E D indicator i s flashing. T u r n off t h e scanner Press t h e Power key for about 3 seconds. The scanner w i l l respond w i t h t w o short beeps (high tone) a n d t h e L E D indicator i s t u r n off. 14

15

16 1.2Transmit Buffer Duringt h e Bluetooth connection, t h e CT30 Scanner u s e s a 2 K B memory a s a d a t a buffer, a n d sends t h e collected data t o t h e h o s t computer o n e b y one v i a t h e Bluetooth. Upon reading a barcode successfully, t h e scanner responds w i t h one short beep a n d i t s L E D indicator becomes green and goes o f f quickly. However, t h e h o s t computer may n o t receive the data immediately if getting out of range. With the 2KB transmit buffer, the scanner can ignore t h e transmission status a n d keep o n reading barcodes u n t i l t h e buffer i s full. When t h e buffer i s full, t h e scanner will respond w i t h a l o n g beep (low tone), t h i s reminds t h e u s e r t h a t t h e space o f buffer i s not enough a n d can not read barcode a n y Once t h e Buffer i s full, t h e u s e r should return t o t h e range o f BT connection quickly, t h e data i n t h e buffer can b e sent b a c k t o t h e h o s t computer a n d release t h e space of buffer. N o t e : The 2KB t r a n s m i t buffer o n t h e scanner can h o l d a s many a s barcodes bases o n EAN13. Y o u can choose t o clear t h e data i n t h e buffer e v e r y t i m e when y o u t u r n o n t h e scanner. Enable ClearDatai n Buffer When Turn On the Scanner *Disable Clear Data in Buffer When Turn On the Scanner N o t e : Y o u can clear t h e d a t a i n t h e buffer v i a enable barcode, y o u can a l s o clear t h e d a t a i n t h e buffer v i a p r e s s t h e Power key l o n g t i m e. After t h e Bluetooth connect successfully, t h e barcodes i n t h e buffer will upload t o appointed position automatically. You also can setup upload the barcodes in the buffer or n o t v i a read t h e following barcodes. By default, i t i s enabled. I f y o u d o n t want t o upload t h e barcodes automatically, y o u can setup a s disabled, when t h e Bluetooth connect, t h e barcodes w o n t upload. Y o u can double click Power key t o start upload t h e barcodes. (*)Enable Auto Uploading Disable Auto Uploading E n t e r S e t u p E x i t with S a v e E x i t without S a v e 16

17 1.2.1 Inventory Mode I f y o u want t o keep t h e barcodes i n t h e buffer o f CT30 for multiple uploading, y o u can choose inventory mode. I n inventory mode, CT30 w i l l count t h e number o f t h e barcodes automatically, and control t h e t i m e, position e t c. for uploading. Also, y o u can clear t h e barcodes i n t h e buffer after uploading. Following i s t h e setup method: 1 ) Read Enter Inventory Mode barcode t o enter i n t o t h e inventory mode Enter Inventory Mode 2 ) If you want to recover to normal mode, read the Enter Normal Mode barcode Enter Normal Mode 3 ) Read t h e Clear t h e barcodes i n t h e buffer barcode t o clear t h e barcodes (only suitable for inventory mode) Cleart h e barcodes i n t h e buffer 4 ) Read Data Uploading barcode t o upload t h e barcodes i n t h e buffer (only suitable for inventory mode) DataUploading 5 ) Read Upload Counting barcode to count the number of the barcodes (only suitable for inventory mode) Upload Counting Note:Inventory function can be used under any scan mode mentioned in

18 1.3 LED Indicator The L E D indicators o n CT30 can h e l p t h e u s e r know about t h e current operation status. Colorof LED Indicator Green L E D o n a n d o f f quickly Green L E D o n Every 5 s Purple, Flashing(On/Off ratio 1 :1 ) Blue, Flashing (On/Off ratio 1 :1 ) Blue, Flashing (On/Off ratio 20ms:3s) Red,Flashing (On/Off ratio 1 : 1 ) Meaning Good Read, w i t h o n e short beep (high tone) Indicates t h e CT30 Scanner i n M e m o r y M o d e Indicates the CT30 Scanner in Setting mode Indicates the BT is waiting for connection, the CT30 stores t h e address o f BT w h i c h connects w i t h t h e l a s t t i m e. Indicates t h e CT30 Scanner i s o u t o f range o r can not establish connection w i t h BT, w i t h t w o short beeps(high-low tone) Indicates t h e CT30 Scanner establish a BT connection successfully, w i t h t w o short beeps (low-high tone). Indicates t h e CT30 Scanner reconnect w i t h BT, w i t h two shortbeeps (low-high tone). Indicates the CT30 Scanner has no address of BT w h i c h connects w i t h before. The default BT connect interface i s HID, t h e PIN code i s

19 1.4Beeper The beeper built i n CT30 can h e l p t h e u s e r know about t h e current operation status. Beeping One long beep, high tone One short beep, h i g h t o n e One long beep, low tone Two short beeps, high tone T w o short beeps, low-high t o n e T w o short beeps, high-low t o n e Three short beeps, t o n e descending from high to low Three short beeps, t o n e ascending from l o w t o high Meaning Power o n. I f t h e scanner h a s n o BT address w h i c h could connect with, flashing red. If the scanner has BT address which could connect with, flashing blue. Readbarcode, w i t h green L E D o n a n d o f f quickly Configuration error, with purple flashing; Or transmit buffer full, with green LED on and off quickly Power off. BT connection established, with blue LED flashing (On/Off ratio 20ms:3s). BT connection o u t o f range o r suspended, w i t h b l u e L E D flashing (On/Off ratio 1 : 1 ). Enter o r Exit Setting mode, w i t h purple L E D flashing. Configuration correct, with purple LED flashing; 19

20

21 1.5Scan Modes Three kinds o f scan modes a r e supported b y t h e CT30 Barcode Scanner: Manual Mode By default, t h e scan mode i s set t o Manual Mode. I f t h e u s e r keeps p r e s s t h e Scan Key, t h e CT30 Scanner will e m i t a red light line. This indicates t h e scanner could scan, t h e scanning will not stop until the scanner under the following situation. * Reada barcode successfully; * Release t h e Scan Key. Manual Mode Enter Setup Exit with Save Exit without Save 21

22

23

24 Delay Between Re-Read The delay time between re-read of above scan modes could be set by the following barcode. 400ms 800ms 1s (*)2s 3s 5s 10s 15s For Example: 1. Read the "Enter Setup" barcode; 2. Read the "Auto Power off Mode" barcode; 3. Read the "1s" of the time interval between each scanning barcode; 4. Read the "Exit with Save" barcode. Then enter the Auto Power Off Mode. Enter Setup Exit with Save 24 Exit without Save

25 1.6Symbologies Supported M o s t o f t h e popular barcode symbologies a r e supported b y t h e CT30 Scanner, a s listed below. Refer t o Chapter 4 for details o f e a c h symbology. Symbologies Supported: Enable/Disable Pre-Set Codabar Disable Code1 1 Disable Code9 3 Disable M S I Disable Code1 2 8 Enable UCC/EAN-128 Enable Code3 9 Enable EAN/UPC EAN-8 Disable EAN-13 Enable UPC-A Enable UPC-E Enable ISBN Disable Code2 o f 5 Industrial 2 5 Disable Interleaved 25 Disable Standard 25 Disable 2 / 5 Matrix Disable 25

26 Chapter 2 H o w toconnect with BT 1 Make CT30 full charged, press Power key. If the scanner never connected with the computer before, it will responds with a beep, and flashing red. 2 Have t h e scanner read t h e "Enter Setup" barcode t o enter t h e setting mode. 3 Have t h e scanner read t h e associated barcode t o activate t h e BT connection interface. 4 Have the scanner read the barcodes for related settings. 5 Have t h e scanner read t h e barcode t o e x i t t h e setting mode. 6 The CT30 Scanner will stay active for 1 minute waiting for a connection request from the host(spp) or trying to connect to the host(hid). Contents 2.1.Select Output Interface BT S P P Mode BT HIDMode Setting upa BT connection Connect t o P C v i a BT Connect t o P D A v i a BT

27 2.1. Select Output Interface Either SPP o r HID can b e chosen depending o n t h e need BTSPPMode I f y o u select t h e output interface o f BT SPP, p o r t t o o l t o collect t h e scanned data. y o u may run HyperTerminal.exe o r serial Enable S P P You can setup SPP data batch upload or single upload according to your requirements. SPP Data Batch Upload SPP Data Single Upload BTH I D Mode By default, BT HID i s activated o n t h e CT30 Scanner, a n d t h e keyboard t y p e i s set t o PCAT (US). (*)Enable HID Enter Setup Exit with Save Exit without Save 27

28 2.2Setting up a BT connection Specify t h e PIN Code, i f y o u choose "TheDefault Value 1 ", t h e passkey for setting u p a BT connection i s 10010; I f y o u choose "TheDefault Value 2 ", t h e passkey for setting u p a BT connection i s F o r security concerns, t h e user can a l s o specify a unique PIN code. 1 Readthe "Enter PIN Code" barcode; 2 Readt h e setting barcodes o f parameters' value i n APPENDIX ONE, i f t h e scanner read t h e setting barcodes i n order, i t means t h e PIN code i s (* )Default V a l u e 1 Default V a l u e 2 E n t e r P I N Code Random P I N Code Refer to APPENDIX I. N o t e : Before the CT30 Scanner connects with the other devices, the user should pre-set the scanner. F o r example: The CT30 Scanner i s t r y i n g t o connect w i t h a h o s t computer, t h e setting operation is according to the following steps: 1. Readt h e "Enter Setup" barcode; 2. Readt h e "Enable SPP" barcode; 3. Readt h e "Default Value 1 " ( P I N code i s 10010); 4. Readt h e "Exitw i t h Save" barcode. Enter Setup Exit with Save Exit without Save 28

29 2.3 29

30 The computer will search Bluetooth devices automatically. A few seconds later, y o u will find CT30 i n t h e available devices list, click Next Select Enter t h e device s pairing code, and click N e x t. Input t h e pairing code 10010, a n d click Next 30

31 Y o u can find a prompting a t t h e l o w e r right corner o f your computer desktop, a s following. After around 5 seconds, y o u will hear a beep from CT30, and t h e indicator from red t o blue. T h e n connect successfully. 31

32 Y o u can open a editable textbox (Notepad, w o r d etc.), a n d read t h e barcodes. ( Note: After pairing successfully, open Bluetooth Chat, then you can read the barcodes i n SPP mode.) Now, y o u click Show Bluetooth Devices, y o u can find t h e CT30 i n Devices a n d Printers. 32

33 I f y o u want t o change PIN code o r switch output interface, y o u must remove t h e paired CT30 o n t h e computer first. 33

34 Note: CT30 default mode i s HID Mode, i f y o u want t o u s e SPP mode, just read following barcodes before pairing, other operations is same as HID mode. 34

35 2.4Connect t o PDAv i a BT PDA i s t r y i n g t o connect t o t h e CT30 Scanner (BT SPP). 1. Press t h e Power key a n d t u r n o n t h e CT30 Scanner w i t h correct BT settings, such a s setting u p SPP a s BT t r a n s m i t interface, a n d BT PIN code specified, e t c. 2. F i n d t h e BT i c o n o n PDA, a n d double-click. 3. Click[ A d d NewDevice]. 35

36 4. Choose "CT30",click [Next]. 5. Enter t h e PIN Code. When setting u p a BT connection, i f y o u choose "TheDefault Value 1 ", input 10010; If you choose "The Default Value 2 ", input 40510; if you specified a unique PIN code o n your o w n, input i t. Click [Next]. 6. Click [Finish]. Click[New Transmit Port] in [COM port]. 36

37 7. Choose port number for added device. [COM0] is chosen here. Click [OK]. 37

38 8. Enter serial port application, choose the port number you justset, click [open]. The CT30 Scanner respond w i t h t w o short beeps, a n d t h e indicator i s flashing b l u e (On/Off ratio 20ms:3s), indicating t h e connection between PDA and CT30 i s established successfully. 38

39 2.4.1 One-click Android Connection 1. T u r n o n CT30, read t h e following barcodes continuously E n t e r S e t u p One-click android connection E x i t with S a v e 2. Bluetooth Pairing T u r n o n Bluetooth i n your android device, search CT30 i n available devices, a n d click I t w i l l popup Bluetooth pairing request dialog, input t h e PIN code

40 ClickOK, y o u will hear a beep f r o m CT30, t h a t means pairing successfully, y o u can find paired CT30 on the android device. 40

41 Open a textbox, for example short message, t h e CT30 can read barcodes i n t o t h e textbox. 41

42 2.4.2 One-click iosconnection 1. T u r n o n CT30, a n d read t h e following barcodes continuously E n t e r S e t u p One-click i O S Connection E x i t with S a v e 2.Bluetooth Pairing T u r n o n Bluetooth i n your i o s device, search CT30 i n available devices, a n d click 42

43 I t w i l l popup Bluetooth pairing request dialog, a n d show t h e PIN code F i n d above mentioned numbers i n following barcodes, read t h e m continuously, a n d then read Exit without Save barcode E x i t without S a v e Y o u will hear a beep from CT30 i f connect successfully, a n d i t will show i n t h e paired devices on ios device. 43

44 3. Active or Hide the Input Method During the scanning, you may use the soft keypad if you want to add remark information, you just need double click Power key quickly, it will active the soft keypad. If you double click Power key quickly again, the soft keypad will hide. It is shown as following: 44

45 2.4.3 Connect via BTInput Method 1. Turn on Bluetooth barcode scanner CT30 or CT30 for setup 1 ) Read Enter Setup barcode 2 ) Read Bluetooth Input Method barcode Bluetooth Input Method 3 ) Read Exit w i t h Save barcode 2. Setup CILICO Bluetooth barcode input method Step 1 : T a p Select Input Method 45

46 Select Cilico Bluetooth Input method (support Chinese, English and Japanese) 46

47 Step 2 :Bluetooth Pairing T u r n o n Bluetooth Click Search for devices, and will find CT30/CT30 in available devices 47

48 Clickfor pairing, a n d input t h e PIN code i n following window, t h e n click OK. Y o u w i l l find CT30/ CT30 i n Paired Devices i f pairing successfully. 48

49 Step 3 :Tap Select Bluetooth device ClickCT30/ CT30 i n Bluetooth Paired Device L i s t, i t will connect automatically 49

50 You will hear a beep if connect successfully Step 4:Tap Switch Input Method Select Cilico Bluetooth Input method (support Chinese, English and Japanese), the user can choose according to their requirement 50

51 Step 5:Tap Finish 51

52 Step 6:Open a editable textbox, then can read the barcodes Switch to Chinese input method 52

53 Switch to English input method Switch to Japanese input method 53

54 EDOC ISM31.36.noisimsnarTmuskcehCE-CPU E-CPUelbasiD/elbanE E-CPU noisimsnarTmuskcehCA-CPU tuptuoa-cpu a-cpu1.316.noisimsnartmuskcehc nbsiotrevnoc naeelbasid/elbane nae noisimsnartmuskcehc naeotrevnoc naeelbasid/elbane nae edoc edoc edocicsaluf/dradnats noitacifirevmuskcehc noisimsnartpots/trats edocelbasid/elbane edoc dradnats-52edoc xirtam 52EDOC DEVAELRETNI 52 CODE 3.3 INDUSTRIAL CODE 3.2 CODABAR Chapter 3 SYMBOLOGY SETTINGS In this chapter, a brief on the symbology setting is provided for your reference. Contents 54

55 3.1CODABAR Decide whether o r n o t t o enable Codabar. The CT30 Scanner defaults disable Codabar. Enable Codabar (*)Disable Codabar N o t e : Read the "Disable Codabar" barcode will make the scanner can not read the Codabar barcode. Thus, i f t h e scanner can not read t h e Codabar barcode, please t r y i n g t o read "Enable Codabar" to reset. For example: Enable Codabar. 1. Readt h e "Enter Setup" barcode; 2. Readt h e "Enable Codabar" barcode; 3. Readt h e "Exitw i t h Save" barcode. Enter Setup Exit with Save Exit without Save 55

56 3.2CODE 25 INDUSTRIAL25 Decide whether o r not t o enable Industrial 2 5. The CT30 Scanner defaults disable Industrial 2 5. Enable Industrial25 (* )Disable Industrial25 N o t e : Read the "Disable Industrial 25 " barcode will make the scanner can not read the Industrial 2 5 barcode. Thus, i f t h e scanner can n o t read t h e Industrial 2 5 barcode, please t r y i n g t o read "Enable Industrial 2 5 " t o reset. For example: Enable Industrial Readt h e "Enter Setup" barcode. 2. Readthe "Enable Industrial 25 " barcode. 3. Readt h e "Exitw i t h Save" barcode. Enter Setup Exit with Save Exit without Save 56

57 3.3CODE 25 INTERLEAVED 25 Decide whether o r n o t t o enable Interleaved 2 5. The CT30 Scanner defaults disable Interleaved 25. Enable Interleaved 25 (*)Disable Interleaved 25 N o t e : Read the "Disable Interleaved 25 " barcode will make the scanner can not read the Interleaved 2 5 barcode. Thus, i f t h e scanner can n o t read t h e Interleaved 2 5 barcode, please trying to read "Enable Interleaved 25 " to reset. For example: Enable Interleaved Readthe "Enter Setup" barcode; 2. Readt h e "Enable Interleaved 2 5 " barcode; 3. Readt h e "Exitw i t h Save" barcode. Enter Setup Exit with Save Exit without Save 57

58 3.4CODE 25 MATRIX 25 Decide whether or not to enable Matrix 25. The CT30 Scanner defaults disable Matrix 25 Enable Matrix 25 (*)Disable M a t r i x 25 N o t e : Read t h e "DisableM a t r i x 2 5 " barcode will make t h e scanner can n o t read t h e M a t r i x 2 5 barcode. Thus, i f t h e scanner can not read t h e M a t r i x 2 5 barcode, please t r y i n g t o read "Enable M a t r i x 25" t o reset. For example: Enable Matrix Readt h e "Enter Setup" barcode; 2. Readt h e "Enable M a t r i x 2 5 " barcode; 3. Readt h e "Exitw i t h Save" barcode. Enter Setup Exit with Save Exit without Save 58

59 3.5CODE 25-STANDARD 25 Decide whether o r n o t t o enable Standard 2 5. The CT30 Scanner defaults disable Standard 2 5. Enable Standard 25 (* )Disable Standard 25 N o t e : Readt h e "DisableStandard 2 5 " barcode w i l l make t h e scanner can n o t read t h e Standard 2 5 barcode. Thus, i f t h e scanner can n o t read t h e Standard 2 5 barcode, please t r y i n g t o read "Enable Standard 2 5 " t o reset. For Example: Enable Standard Readt h e "Enter Setup" barcode; 2. Readt h e "Enable Standard 2 5 " barcode; 3. Readt h e "Exitw i t h Save" barcode. Enter Setup Exit with Save Exit without Save 59

60 3.6CODE Enable/Disable Code 39 Decide whether or not to enable Code 39, The CT30 Scanner defaults disable Code 39. (*)Enable Code 39 Disable Code START/STOP Transmission Decide whether or not to include the start/stop characters in the data being transmitted. *Transmit Code 39 Start/Stop Characters *Do Not Transmit Code 39 Start/Stop Characters For example: DoNotTransmit Code39 Start/Stop Characters. 1. Readt h e "Enter Setup" barcode; 2. Readt h e "Enable Code3 9 " barcode; (If Code3 9 i s disabled, i t i s need t o set); 3. Readt h e "DoNotTransmit Code3 9 Start/Stop Characters" barcode; 4. Readt h e "Exitw i t h Save" barcode. Enter Setup Exit with Save Exit without Save 60

61

62 3.6.4 STANDARD/FULL ASCII CODE 39 Decide whether o r n o t t o support Code3 9 F u l l ASCII t h a t includes a l l t h e alphanumeric and special character. The CT30 Scanner defaults full ASCII Code 39. It could disable full ASCII Code3 9 v i a set. Disable Code39 F u l l ASCII * Enable Code39 F u l l ASCII Enter Setup Exit with Save Exit without Save 62

63 3.7CODE 93 Decide whether or not to enable Code 93. The CT30 Scanner defaults disable Code 93. Enable Code93 (*)Disable Code93 N o t e : Readt h e "DisableCode9 3 " barcode will make t h e scanner can n o t read t h e Code 9 3 barcode. Thus, i f t h e scanner can n o t read t h e Code9 3 barcode, please t r y i n g t o read "Enable Code 93 " to reset. For Example: Enable Code Readt h e "Enter Setup" barcode; 2. Readt h e "Enable Code9 3 " barcode; 3. Readt h e "Exitw i t h Save" barcode. Enter Setup Exit with Save Exit without Save 63

64 3.8Code 128 Decide whether or not to enable Code 128. The CT30 Scanner defaults enable Code 128. (*)Enable Code128 Disable Code128 N o t e : Read t h e "DisableCode 128" barcode will make t h e scanner can n o t read t h e Code1 2 8 barcode. Thus, i f t h e scanner can not read t h e Code128 barcode, please t r y i n g t o read "Enable Code128" t o reset. For Example: Disable Code Readt h e "Enter Setup" barcode; 2. Readt h e "DisableCode128" barcode; 3. Readt h e "Exitw i t h Save" barcode. Enter Setup Exit with Save Exit without Save 64

65 3.9EAN Enable/Disable EAN-8 Decide whether or not to enable EAN-8. The CT30 Scanner defaults enable EAN-8. (*)Enable EAN-8 Disable EAN Convert t o EAN-13 There i s t w o w a y s for EAN-8 t o change, convert t o EAN-13, o r a d d "0"ahead o f EAN-8, a n d t h e EAN-8 I D i s n o t change. Decide whether o r n o t t o convert t o EAN-13, i f EAN-8 convert t o EAN-13, i t will b e read a s same a s EAN-13. I f a d d a "0"ahead o f EAN-8, a n d t h e EAN-8 I D i s n o t change, t h e output I D i s still EAN-8 I D. Convert t o EAN-13 Add "0"ahead a n d I D i s n o t change (* )Donot Convert Enter Setup Exit with Save Exit without Save 65

66

67 3.10 EAN Enable/Disable EAN-13 Decide whether or not to read EAN-13. The CT30 Scanner defaults enable EAN-13. (*)Enable EAN-13 Disable EAN Convert t o ISBN Decide whether o r n o t t o convert t h e EAN-13 t o I S B N. Convert EAN-13 to ISBN * DoNotConvert EAN-13 t o I S B N Enter Setup Exit with Save Exit without Save 67

68

69

70 3.12 UPC-E Enable/Disable UPC-E Decide whether o r n o t t o enable UPC-E. The CT30 Scanner defaults enable UPC-E. (*)Enable UPC-E Disable UPC-E UPC-E Checksum Transmission Decide whether o r n o t t o include t h e checksum character i n t h e d a t a being transmitted. *Transmit UPC-E Checksum DoNotTransmit UPC-E Checksum For example: DoNotTransmit UPC-E Checksum 1. Readt h e "Enter Setup" barcode; 2. Readt h e "Enable UPC-E" barcode; 3. Readt h e "DoNotTransmit UPC-E Checksum" barcode; 4. Readt h e "Exitw i t h Save" barcode. Enter Setup Enter with Save Enter without Save 70

71 3.13 MSI Decide whether or not to enable MSI. The CT30 Scanner defaults disable MSI. Enable M S I (* )Disable M S I N o t e : Read t h e "DisableM S I " barcode will make t h e scanner can n o t read t h e M S I barcode. Thus, i f t h e scanner can n o t read t h e M S I barcode, please t r y i n g t o read "Enable MSI " to reset. For example: Enable MSI. 1. Readt h e "Enter Setup" barcode; 2. Readt h e "Enable M S I " barcode; 3. Readthe "Exitwith Save" barcode. Enter Setup Exit with Save Exit without Save 71

72 3.14 CODE 1 1 Decide whether or not to enable Code 11. The CT30 Scanner defaults disable Code 11. Enable Code11 (* )Disable Code11 N o t e : Readt h e "Disable Code1 1 " barcode will make t h e scanner can not read t h e Code 1 1 barcode. Thus, i f t h e scanner can n o t read t h e Code1 1 barcode, please t r y i n g t o read "Enable Code 11 " to reset. For example: Enable Code Readt h e "Enter Setup" barcode; 2. Readt h e "Enable Code1 1 " barcode; 3. Readt h e "Exitw i t h Save" barcode. Enter Setup Exit with Save Exit without Save 72

73 4.1 Settings APPENDIX I Barcode of Code Suffix 4.2 ID...67 CODE Chapter 4 DEFINING OUTPUT FORMAT Before data transmission to the host or device, you can pre-process the data and decide the format of the data transfer. Contents _Toc

74 4.1 74

75 4.2 75

76 APPENDIX I The setting barcodes of parameters' value

SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide

SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide This page is intentionally left blank. SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide The ACTiSys IR Programmer and SuperCELL

More information

O P E R A T I N G M A N U A L

O P E R A T I N G M A N U A L OPERATING MANUAL WeatherJack OPERATING MANUAL 1-800-645-1061 The baud rate is 2400 ( 8 bits, 1 stop bit, no parity. Flow control = none) To make sure the unit is on line, send an X. the machine will respond

More information

Bright Advance Corporation

Bright Advance Corporation USER INSTRUCTIONS TABLE OF CONTENTS INSTRUCTIONS FOR USE2 PREPARING TO USE THE SCALE2 DISPLAYS3 KEYBOARD FUNCTION4 OPERATION7 COUNTING14 DIFFERENT KEYBOARD TYPES21 INTERFACE31 POWER SOURCES40 1 INSTRUCTIONS

More information

IDENTIFICATION STS400

IDENTIFICATION STS400 IDENTIFICATION APPLICATIONS Tracking and Traceability is a primary need of tire manufactures. In logistics, WIP, quality control, and compliance, tires get tracked at every step of production process.

More information

PiCUS Calliper Version 3

PiCUS Calliper Version 3 Technology PiCUS Calliper Version 3 Digital calliper for precise geometry detection argus electronic GmbH Erich-Schlesinger-Straße 49d 18059 Rostock Germany Tel.: +49 (0) 381/49 68 14 40 www.argus-electronic.de

More information

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER nu-beca NO TOUCH THERMOMETER : Thank you for purchasing the nu-beca No Touch Forehead Thermometer. Please read this instruction manual first so you can use this

More information

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a

More information

Connect the Vernier spectrometer to your lap top computer and power the spectrometer if necessary. Start LoggerPro on your computer.

Connect the Vernier spectrometer to your lap top computer and power the spectrometer if necessary. Start LoggerPro on your computer. Connect the Vernier spectrometer to your lap top computer and power the spectrometer if necessary. Start LoggerPro on your computer. The screen shown in Fig. 1 may be displayed. If status line displays

More information

Lightcloud Application

Lightcloud Application Controlling Your Lightcloud System Lightcloud Application Lightcloud Application Navigating the Application Devices Device Settings Organize Control Energy Scenes Schedules Demand Response Power Up State

More information

User's Guide. DISTO online. Leica Geosystems

User's Guide. DISTO online. Leica Geosystems User's Guide DISTO online Leica Geosystems Copyright 2001 by PMS Photo Mess Systeme AG. All rights reserved. This manual describes the versions 2.x of the program DISTO online. PMS PHOTO-MESS-SYSTEME AG

More information

Software BioScout-Calibrator June 2013

Software BioScout-Calibrator June 2013 SARAD GmbH BioScout -Calibrator 1 Manual Software BioScout-Calibrator June 2013 SARAD GmbH Tel.: ++49 (0)351 / 6580712 Wiesbadener Straße 10 FAX: ++49 (0)351 / 6580718 D-01159 Dresden email: support@sarad.de

More information

PC Control / Touch Control

PC Control / Touch Control PC Control / Touch Control Version 6.0 / 5.840.0150 New Features Manual 8.840.8007EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com

More information

Operation Manual Contents subject to change without notice

Operation Manual Contents subject to change without notice 318513 Operation Manual Contents subject to change without notice Version 1.0 Issue AA TABLE OF CONTENTS 1. INTRODUCTION and INSTALLATION... 1 General and Safety Information... 1 Specifications... 1 Contents...

More information

T R A I N I N G M A N U A L 1. 9 G H Z C D M A P C S 80 0 M H Z C D M A /A M P S ( T R I - M O D E ) PM325

T R A I N I N G M A N U A L 1. 9 G H Z C D M A P C S 80 0 M H Z C D M A /A M P S ( T R I - M O D E ) PM325 T R A I N I N G M A N U A L 1. 9 G H Z C D M A P C S 80 0 M H Z C D M A /A M P S ( T R I - M O D E ) PM325 Slide. Click. Send the pic O P E R AT I N G I N S T RU C T I O N S H e a d s e t Ja c k S e l

More information

WT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual

WT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual WT-3131A Radio-controlled Analog Clock With Weather Forecast Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents/Additional Equipment 2 About WWVB 2 Detailed Set-Up Guide Battery Installation

More information

WeatherHub2 Quick Start Guide

WeatherHub2 Quick Start Guide WeatherHub2 Quick Start Guide Table of Contents 1 Introduction... 1 2 Packing List... 1 3 Connections... 1 4 IP Addressing... 2 5 Browser Access... 3 6 System Info... 3 7 Weather Station Settings... 4

More information

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically Complete Set ph PRO Controller - 1 pcs. ph electrode - 1 pcs. Calibration

More information

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 - Non - Contact Forehead Infrared Thermometer Care Q7 USER MANUAL - 1 - Contents: 1. Introduction... 1 2. Safety precautions... 1 3. Features... 2 4. Product description... 2 5. Display description... 3

More information

XR Analog Clock - Manual Setting Model Troubleshooting Guide

XR Analog Clock - Manual Setting Model Troubleshooting Guide Primex XR 72MHz Synchronized Time Solution XR Analog Clock - Manual Setting Model Troubleshooting Guide 2018 Primex. All Rights Reserved. The Primex logo is a registered trademark of Primex. All other

More information

User's Manual altimeter V1.1

User's Manual altimeter V1.1 User's Manual altimeter V1.1 The altimeter is completely autonomous. It can be installed on any model. It automatically detects the beginning of flights and does not record the period between two consecutive

More information

ISSP User Guide CY3207ISSP. Revision C

ISSP User Guide CY3207ISSP. Revision C CY3207ISSP ISSP User Guide Revision C Cypress Semiconductor 198 Champion Court San Jose, CA 95134-1709 Phone (USA): 800.858.1810 Phone (Intnl): 408.943.2600 http://www.cypress.com Copyrights Copyrights

More information

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science C101-E112 BioSpec-nano Shimadzu Spectrophotometer for Life Science Power of small. BioSpec-nano BioSpec-nano Shimadzu Spectrophotometer for Life Science Quick and Simple Nucleic Acid Quantitation Drop-and-Click

More information

GW Professional Weighing Scale. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW

GW Professional Weighing Scale. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW GW Professional Weighing Scale User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW 20100415 Table of Contents Table of Contents...1 Specifications... 2 Basic specification... 2 Series specification(ec TYPE/OIML

More information

Assembly and Operation Manual. April 2016

Assembly and Operation Manual. April 2016 Assembly and Operation Manual April 2016 Table of Contents What is in the OurWeather Box? 3 Step by Step Assembly 13 Building the Weather Sensors 18 Testing the OurWeather Weather Station 28 Power Up OurWeather

More information

Chemistry MultiMeasure Sensor PS-2170

Chemistry MultiMeasure Sensor PS-2170 ä 5 Instruction Manual 012-09523A Chemistry MultiMeasure Sensor PS-2170 ph/ise/orp PRESSURE CHEMISTRY TEMPERATURE SENSOR VOLTAGE 1 2 3 4 PS-2170 5 6 7 cc 8 10 15 20 25 30 35 40 45 50 55 60 Included Equipment

More information

ST-Links. SpatialKit. Version 3.0.x. For ArcMap. ArcMap Extension for Directly Connecting to Spatial Databases. ST-Links Corporation.

ST-Links. SpatialKit. Version 3.0.x. For ArcMap. ArcMap Extension for Directly Connecting to Spatial Databases. ST-Links Corporation. ST-Links SpatialKit For ArcMap Version 3.0.x ArcMap Extension for Directly Connecting to Spatial Databases ST-Links Corporation www.st-links.com 2012 Contents Introduction... 3 Installation... 3 Database

More information

Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT

Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT OUTDOOR SENSOR FEATURES Buttons: MODE,,,MEM, CH, HISTORY, 5 day weather forecast in the following combinations:

More information

AW/AHW Professional Weighing Scale. User Manual

AW/AHW Professional Weighing Scale. User Manual AW/AHW Professional Weighing Scale User Manual Sep. 2009 Table of Contents Specifications... 2 Basic specification... 2 Series specification... 2 Display and keypad... 3 LCD Display... 3 Keypad... 4 Using

More information

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Operation Manual SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC. 4.18 Foreword

More information

Wireless Weather Station Instruction Manual

Wireless Weather Station Instruction Manual Wireless Weather Station Instruction Manual I. FEATURES 1. Wireless temp.& humidity 2. Radio-controlled clock (RCC) 3. Weather forecast 4. Weather trend 5. Display of barometric pressure with bar chart

More information

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL INDEX GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL Introduction...2 Overview...2 Front view...2 LCD screen...3 Battery replacement...3 Displays...4 Operation modes...4 Time / date / alarm...4

More information

To Set Time: Turn the set knob on back of the clock movement in either direction.

To Set Time: Turn the set knob on back of the clock movement in either direction. Instruction Manual Clock/Thermometer DO NOT HANG IN DIRECT SUNLIGHT! For the most accurate temperature readings choose a location that will not be exposed to direct sunlight or other heat sources. To Set

More information

GPS Mapping with Esri s Collector App. What We ll Cover

GPS Mapping with Esri s Collector App. What We ll Cover GPS Mapping with Esri s Collector App Part 1: Overview What We ll Cover Part 1: Overview and requirements Part 2: Preparing the data in ArcGIS for Desktop Part 3: Build a web map in ArcGIS Online Part

More information

TitriSoft 2.5. Content

TitriSoft 2.5. Content Content TitriSoft 2.5... 1 Content... 2 General Remarks... 3 Requirements of TitriSoft 2.5... 4 Installation... 5 General Strategy... 7 Hardware Center... 10 Method Center... 13 Titration Center... 28

More information

Dual laser + type K thermometer INFRARED THERMOMETER

Dual laser + type K thermometer INFRARED THERMOMETER Dual laser + type K thermometer INFRARED THERMOMETER Model : ATE-2509 Your purchase of this INFRARED THERMOMETER marks a step forward for you into the field of precision measurement. Although this METER

More information

University of Colorado Denver Anschutz Medical Campus Online Chemical Inventory System User s Manual

University of Colorado Denver Anschutz Medical Campus Online Chemical Inventory System User s Manual University of Colorado Denver Anschutz Medical Campus Online Chemical Inventory System User s Manual Hazardous Materials Division 303-724-0345 chemical.inventory@ucdenver.edu May, 2017 Table of Contents

More information

R I T. Title: GCA Stepper Operations. Semiconductor & Microsystems Fabrication Laboratory Revision: F Rev Date: 08/09/ SCOPE

R I T. Title: GCA Stepper Operations. Semiconductor & Microsystems Fabrication Laboratory Revision: F Rev Date: 08/09/ SCOPE Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the GCA Stepper. All users are expected to have read and understood this document.

More information

244241, Operation Manual Contents subject to change without notice. Version 1.0 Issue AA

244241, Operation Manual Contents subject to change without notice. Version 1.0 Issue AA 244241, 244242 Operation Manual Contents subject to change without notice Version 1.0 Issue AA CONTENTS 1. INTRODUCTION... 2 General and Safety Information... 2 2. TECHNICAL SPECIFICATIONS... 2 3. DISPLAY

More information

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX LANCER reserves the right to modify, constantly its documentation for its improvement. The values of adjustments indicated in the displays of this manual are

More information

Structure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor

Structure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor Rain detection sensor General Description Driving rain and its effective management are critical factors in determining the durability of building enclosures. An accurate measurement of driving rain can

More information

A clock designed in close consultation with people living with Dementia.

A clock designed in close consultation with people living with Dementia. 1. Product Name Day Clock 2. Product Code 55787 3. Colour As shown 4. Brief Description A clock designed in close consultation with people living with Dementia. 5. Contents 1 x Day Clock 6. Snoezelen Stimulations

More information

Wireless Weather Station. Instruction Manual

Wireless Weather Station. Instruction Manual Wireless Weather Station Instruction Manual Congratulations on purchasing this state-of-the-art Weather Station as an example of fine design and quality piece of engineering. The operation of this product

More information

Data Sheet / Instructions. Dewpoint MeterO

Data Sheet / Instructions. Dewpoint MeterO Data Sheet / Instructions Dewpoint MeterO Dewpoint Meter ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment of surface cleanliness.

More information

SOFTWARE USER MANUAL. Weather Capture Advance WS1640 WM9280

SOFTWARE USER MANUAL. Weather Capture Advance WS1640 WM9280 SOFTWARE USER MANUAL Weather Capture Advance WS1640 WM9280 1 TABLE OF CONTENTS 1. Introduction 3 1.1 System requirements 1.2 Connection of the weather station 1.3 Installation of the Weather Capture Advance

More information

Minimum (-31) every 10 s -35 (-31)

Minimum (-31) every 10 s -35 (-31) Humidity, and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-2-LCD BAT 3V6 1/2AA FEATURES 0 to 100 measurement

More information

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started Model: WT-3181PL Instruction Manual DC: 041614 18 Indoor/Outdoor Atomic Wall Clock Round Battery Cover Get Started Step 1: Remove the round battery cover from the back of the clock. Step 2: Insert 1 fresh

More information

CA84688 FAQS TABLE OF CONTENTS

CA84688 FAQS TABLE OF CONTENTS CA84688 FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader TABLE

More information

VISY-Quick Communication Protocol

VISY-Quick Communication Protocol VISY-Quick Communication Protocol Rev. Protocol Version Modification VI Version Date Name 0 1.00 First release 2.0.1 2000-03-29 Willmer 1 1.10 New commands date and time (3.2... 3.5) 2.0.2 2000-07-07 Willmer

More information

WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual

WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual WS-7038U Wireless 433 MHz Miniature Rain Monitor Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents/ Additional Equipment 3 Quick Set-Up Guide 3 Detailed Set-Up Guide Battery Installation

More information

Explanation: The factory restart returns the atomic clock to an out-of-the-box state and often resolves an issue.

Explanation: The factory restart returns the atomic clock to an out-of-the-box state and often resolves an issue. 404-1220 FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader CONTENTS

More information

Training Guide. Coastal Environmental Systems, Inc.

Training Guide. Coastal Environmental Systems, Inc. WEATHERPAK TRx2 Coastal Environmental Systems, Inc. 820 First Avenue South Seattle, WA 98134 206.682.6048 800.488.8291 206.682.5658 Fax www.coastalenvironmental.com 11-16-2012 WEATHERPAK is the #1 Choice

More information

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5. HMS-5000 Manual Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K - Manual version: ver 5.01- www.ecopia21.co.kr - Table of contents - 1. Hardware Installation

More information

Dewpoint Meter Data Sheet / Instructions

Dewpoint Meter Data Sheet / Instructions Paint Test Equipment Dewpoint Meter Data Sheet / Instructions Dewpoint Meter Information ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment

More information

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1 515-1316 FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader CONTENTS

More information

Today s Weather 24 Hour Forecaster

Today s Weather 24 Hour Forecaster 1380 Today s Weather 24 Hour Forecaster Instruction Manual The Taylor 24 Hour Forecaster will provide you with actual current temperatures. Predict the weather conditions for the next 24 hours as well

More information

Jasco V-670 absorption spectrometer

Jasco V-670 absorption spectrometer Laser Spectroscopy Labs Jasco V-670 absorption spectrometer Operation instructions 1. Turn ON the power switch on the right side of the spectrophotometer. It takes about 5 minutes for the light source

More information

Microcare LCD Solar MPPT User Documentation

Microcare LCD Solar MPPT User Documentation Microcare LCD Solar MPPT User Documentation 1 CONTENTS 1. INTRODUCTION. 3 1.1. General Description 1.2. Key Features 1.3. Important Notices 1.4. Recommended Array Sizes 1.5. MPPT Description 1.6. MPPT

More information

QUANTUM CONCEPT. Swimming User s Manual

QUANTUM CONCEPT. Swimming User s Manual QUANTUM CONCEPT Swimming User s Manual 480.508.0 Version.4 Edition July 05 Documentation Updates Swiss Timing Ltd. reserves the right to make improvements in the products described in this documentation

More information

Automatic titrators, TitroMatic

Automatic titrators, TitroMatic 112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator

More information

Circular Motion and Centripetal Force

Circular Motion and Centripetal Force [For International Campus Lab ONLY] Objective Measure the centripetal force with the radius, mass, and speed of a particle in uniform circular motion. Theory ----------------------------- Reference --------------------------

More information

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4. KL4912 Desktop weather station Instruction Manual Introduction This weather station comes with backlight, indoor and outdoor temperature & humidity display, and alarm clock with calendar. Fig. 1 Front

More information

Hadrons Desktop U.S. Atomic Clock & Weather Station

Hadrons Desktop U.S. Atomic Clock & Weather Station Hadrons Desktop U.S. Atomic Clock & Weather Station SN004 Instructions Read and save these instructions. Dear Sharper Image Customer, Thank you for your purchase of a Sharper Image product. We appreciate

More information

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014 Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5

More information

Quantum Series Product Catalog

Quantum Series Product Catalog Measuring and Managing Healthy Living Quantum Series Product Catalog RJL Sciences is an FDA registered company RJL Sciences, Inc. 33939 Harper Avenue Clinton Township, MI 48035 USA Voice: 1-800-528-4513

More information

Product manual. Mylos KNX Shutter actuator 2CSY1104C/S

Product manual. Mylos KNX Shutter actuator 2CSY1104C/S Product manual Mylos KNX Shutter actuator 2CSY1104C/S Contents Contents 1 Technical features... 3 1.1 Technical data... 3 1.2 Connection diagram... 4 2 Commissioning... 5 2.1 Parameters... 5 2.1.1 General...

More information

PC100 Handheld ph/cond./tds/sal. Meter. Instruction Manual

PC100 Handheld ph/cond./tds/sal. Meter. Instruction Manual PC100 Handheld ph/cond./tds/sal. Meter Instruction Manual Table of Contents 1. Introduction ------------------------------------------------------------------------------------------------------------------------

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this 3 in 1 VIBRATION TACHOMETER Model : VT-8204 Your purchase of this VIBRATION TACHOMETER marks a step forward for you into the field of precision measurement. Although this VIBRATION TACHOMETER is a complex

More information

Humidity, and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-2-LCD BAT 3V6 1/2AA FEATURES 0 to 100 measurement

More information

OP-02 / OP-03 / OP-04

OP-02 / OP-03 / OP-04 FS-i Series Check Weighing Scales Option OP-02 / OP-03 / OP-04 WM+PD4001368 Contents 1. OP-02 BATTERY... 2 1-1. Using the OP-02 SLA Battery... 2 2. OP-03 RS-232C / RELAY OUTPUT... 4 2-1. Installation...

More information

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual HL-800K Infrared Laser Thermometer -50 C to +800 C (13:1 ratio) User Manual TABLE OF CONTENTS INTRODUCTION... 3 FEATURES... 3 WIDE APPLICATION RANGE... 3 SAFETY... 3 DISTANCE & SPOT SIZE... 4 SPECIFICATIONS...

More information

WEATHERPAK TRx Training Guide

WEATHERPAK TRx Training Guide WEATHERPAK TRx Coastal Environmental Systems, Inc. 820 First Avenue South Seattle, WA 98134 206.682.6048 800.488.8291 206.682.5658 Fax www.coastalenvironmental.com 11-16-2012 WEATHERPAK is the #1 Choice

More information

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

MN-ISO-2000FN-E.   ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL MN-ISO-2000FN-E www.insize.com ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL V0 Place the probe on the zero plate and wait until beep. Lift the probe for minimal 5 cm off the zero plate and wait

More information

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product. Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure

More information

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909) HS515G-M PARALOW Circle Dot Sight User's Manual Multi Reticle Holosun Technologies Inc. Phone: (909) 594-2888 Fax: (909) 598-4888 E-mail: info@holosun.com COLOR www.holosun.com PARALOW HS515G-M PARALOW

More information

U.S. Atomic Clock & Weather Station. Instruction Manual

U.S. Atomic Clock & Weather Station. Instruction Manual U.S. Atomic Clock & Weather Station Instruction Manual Table of Contents What is Atomic Radio Control?... 2 Parts Diagram... 3 Batteries... 4 Setting the Atomic Time and Date... 4 Setting the Clock...

More information

INFRARED THERMOMETER TM0819

INFRARED THERMOMETER TM0819 INFRARED THERMOMETER Instruction Manual HORMES LIMITED cs@perfectprime.com G/F UNIT 3, 61 GLENTHORNE ROAD, LONDON W6 0LJ UNITED KINGDOM +44 203 7695377 Retailer Email Address Telephone P.1 CONTENTS 1.

More information

Differential Pressure Sensor

Differential Pressure Sensor Differential Pressure Sensor MDP200 Series Features Pressure range up to ±500Pa with high accuracy of ±3.0% m.v. Pressure based on thermal micro-flow measurement Outstanding hysteresis and repeatability

More information

Title: ASML PAS 5500 Job Creation Semiconductor & Microsystems Fabrication Laboratory Revision: D Rev Date: 09/20/2012

Title: ASML PAS 5500 Job Creation Semiconductor & Microsystems Fabrication Laboratory Revision: D Rev Date: 09/20/2012 Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the creation of stepper jobs for the ASML PAS 5500. All users are expected to have read and understood

More information

Acceleration/Velocity/Displacement VIBRATION METER

Acceleration/Velocity/Displacement VIBRATION METER Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex

More information

Mass Asset Additions. Overview. Effective mm/dd/yy Page 1 of 47 Rev 1. Copyright Oracle, All rights reserved.

Mass Asset Additions.  Overview. Effective mm/dd/yy Page 1 of 47 Rev 1. Copyright Oracle, All rights reserved. Overview Effective mm/dd/yy Page 1 of 47 Rev 1 System References None Distribution Oracle Assets Job Title * Ownership The Job Title [list@yourcompany.com?subject=eduxxxxx] is responsible for ensuring

More information

Cosmic Ray Detector Software

Cosmic Ray Detector Software Cosmic Ray Detector Software Studying cosmic rays has never been easier Matthew Jones Purdue University 2012 QuarkNet Summer Workshop 1 Brief History First cosmic ray detector built at Purdue in about

More information

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual WD1063 Rev B Revised 02/23/15 Wahl Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131

More information

WEATHERPAK MTR Training Guide

WEATHERPAK MTR Training Guide WEATHERPAK MTR Coastal Environmental Systems, Inc. 820 First Avenue South Seattle, WA 98134 206.682.6048 800.488.8291 206.682.5658 Fax www.coastalenvironmental.com 11-15-2012 WEATHERPAK is the #1 Choice

More information

E THERMADATA LOGGER Humidity & temperature recording meter

E THERMADATA LOGGER Humidity & temperature recording meter E 07 00 THERMADATA LOGGER Humidity & temperature recording meter THERMADATA LOGGER Data-loggers are electronic devices that record temperature over a period of time for analysis at a later date. The user

More information

MULTIFUNCTION COMPUTER METER CX-742 USERS MANUAL

MULTIFUNCTION COMPUTER METER CX-742 USERS MANUAL MULTIFUNCTION COMPUTER METER CX-742 USERS MANUAL CONTENTS 1. BASIC INFORMATION 3 2. USING THE INFORMATION 4 3. THE PROFILE OF THE METER 5 4. TECHNICAL DATA 7 5. SCREENS 8 6. USING THE KEYBOARD 10 7. THE

More information

What s New in Collector for ArcGIS (Aurora)

What s New in Collector for ArcGIS (Aurora) What s New in Collector for ArcGIS (Aurora) Derek Law (dlaw@esri.com) Esri Apps Product Management @GIS_Bandit Oct 10 th, 2018 Agenda Product overview Use cases Preparing data for Collector for ArcGIS

More information

FAQS. La Crosse Technology, Ltd. Page 1

FAQS. La Crosse Technology, Ltd.   Page 1 308-1412 FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader CONTENTS

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities instruments 5 YEARS G U A R A N T E E Quality at a reasonable price The optimum combination

More information

WS-9018U Wireless Weather Station. Instruction Manual

WS-9018U Wireless Weather Station. Instruction Manual WS-9018U Wireless Weather Station Instruction Manual Contents Page 1. Functions of the Weather Station....3 2. Safety notes...3 3. Product features....4 4. Getting started....4 5. Quick Set Up...5 6. Setting

More information

Skin Damage Visualizer TiVi60 User Manual

Skin Damage Visualizer TiVi60 User Manual Skin Damage Visualizer TiVi60 User Manual PIONEERS IN TISSUE VIABILITY IMAGING User Manual 3.2 Version 3.2 October 2013 Dear Valued Customer! TiVi60 Skin Damage Visualizer Welcome to the WheelsBridge Skin

More information

1450 First Ave. Page 1 of 10 Chippewa Falls, WI (800) or (715) Fax: (715)

1450 First Ave. Page 1 of 10 Chippewa Falls, WI (800) or (715) Fax: (715) 1450 First Ave. Page 1 of 10 Model DA40T User Manual 1450 First Ave. Page 2 of 10 Warranty This product is fully warranted against defective materials and/or workmanship for a period of one year after

More information

for MiLAB Desktop Experiments in Physics imagine explore learn

for MiLAB Desktop Experiments in Physics imagine explore learn Experiments in Physics for MiLAB Desktop imagine explore learn www.einsteinworld.com 4 5 6 7 This book contains 48 student experiments in Physics. For your convenience we have added an index in which

More information

Instruction Manual. Solar Weather Centre With Wireless Weather Vane. Product Code: WS5056C. Solar Powered Outdoor Weather Data Collector

Instruction Manual. Solar Weather Centre With Wireless Weather Vane. Product Code: WS5056C. Solar Powered Outdoor Weather Data Collector Solar Weather Centre With Wireless Weather Vane Solar Powered Outdoor Weather Data Collector Indoor Receiver Instruction Manual Product Code: WS5056C TECHNICAL DETAILS Thank you for purchasing the Holman

More information

SOFTWARE. Control of the AMS SYSTEM CONTROL AND MONITORING OF AIRFIELD GROUND LIGHTING EQUIPMENT

SOFTWARE. Control of the AMS SYSTEM CONTROL AND MONITORING OF AIRFIELD GROUND LIGHTING EQUIPMENT Control of the AMS SYSTEM SOFTWARE CONTROL AND MONITORING OF AIRFIELD GROUND LIGHTING EQUIPMENT Description of function airfield ground lighting equipment are shown on the screen representing the airport

More information

DobsonDream. Push-TO DSC controller User guide

DobsonDream. Push-TO DSC controller User guide DobsonDream Push-TO DSC controller User guide Astro-Gadget.com 2017 1. APPOINTMENT AND OPPORTUNITIES DobsonDream is a DSC controller (digital telescope guidance circles). It helps observers to accurately

More information

Nixie Clock Manuela Desktop. User Manual

Nixie Clock Manuela Desktop. User Manual Nixie Clock Manuela Desktop User Manual May 2011 Safety Precautions Do not power on the clock when tubes are damaged or missing. Use the power supply that came with the clock, or use a power supply that's

More information

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base INTRODUCTION Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base Chemists frequently make use of the equivalent weight (eq. wt.) as the basis for volumetric calculations.

More information

Location Intelligence Infrastructure Asset Management. Confirm. Confirm Mapping Link to ArcMap Version v18.00b.am

Location Intelligence Infrastructure Asset Management. Confirm. Confirm Mapping Link to ArcMap Version v18.00b.am Location Intelligence Infrastructure Asset Management Confirm Confirm Mapping Link to ArcMap Version v18.00b.am Information in this document is subject to change without notice and does not represent a

More information