Gas Chromatography CHEM Dr. Reem M. Alghanmi st term

Size: px
Start display at page:

Download "Gas Chromatography CHEM Dr. Reem M. Alghanmi st term"

Transcription

1 Gas Chromatography CHEM Dr. Reem M. Alghanmi st term

2 17.7 Gas Chromatography Introduction There are two types of gas chromatography: Gas-solid (adsorption) chromatography. Gas-liquid (partition) chromatography (GLC). The most important of the two is GLC. Gas chromatography is widely used, particularly by organic chemists, and it certainly rank as one of the most important new analytical techniques since it development in The separation of benzene and cyclohexane (b.p and 80.8ºC) is extremely simple by gas chromatography, but it is virtually impossible by conventional distillation. Very complex mixtures can be separated by this technique. 2

3 Principles 3 In gas chromatography the sample is converted to the vapor state (if it is not already a gas) and the eluent is a gas (the carrier gas). The stationary phase is generally a nonvolatile liquid supported on an inert solid such as firebrick. There are a large number of liquid phases available, and it is by changing this phase rather than the mobile gas phase that different separations are accomplished. The analyte in the vapor state distributes between the stationary phase and the carrier gas. Gas phase equilibria are rapid and so resolution and the number of theoretical plates can be high.

4 4

5 Principles 5 A schematic diagram of a gas chromatography is given in Fig The sample is rapidly injected by means of a hypodermic syringe through a rubber septum into the column. The sample injection port, column, and detector are heated to temperatures at which the sample has a vapor pressure of at least 10 torr. The injection port and detector are usually kept somewhat warmer than the column to promote rapid vaporization of the injected sample and prevent sample condensation in the detector. Liquid samples of 0.1 to 10 µl are injected, while gas samples of 1 to 10 ml are injected.

6 Principles 6 Separation occurs as the vapor constituents partition between the gas and the liquid phases in the same manner as in other chromatographic processes. The carrier gas is a chemically inert gas available in pure form, such as argon, helium, nitrogen or carbon dioxide. A high-density gas gives best efficiency, but a low-density gas gives faster speed. The choice of gas is often dictated by the type of detector. The sample is automatically detected as it emerges from the column (at a constant flow rate), using a variety of detectors whose response is dependent upon the composition of the vapor.

7 Principles 7 Usually, the detector contains a reference side and a sampling side. The carrier gas is passed through the reference side before entering the column and emerges from the column through the sampling side. The response of sampling side relative to the reference side signal is fed to a recorder where the chromatographic peaks are recorded as a function of time. By measuring the retention time (the minutes between the time the sample is injected and the time the chromatographic peak is recorded) and comparing this time with that of a standard of the pure substance, it may be possible to identify the peak (agreement of retention times of two compounds dose not guarantee the compounds are identical).

8 Principles 8 The area under the peak is proportional to the concentration, and so the amount of substance can be quantitatively determined. The peaks are often very sharp and, if so, the peak height is taken and compared with a calibration curve prepared in the same manner. Automatic detection of the analyte as they emerge from the column make measurements rapid and convenient. Retention times are used for qualitative identification. Peaks areas are used for quantitative measurements.

9 Principle The separation ability of this

10 Gas Chromatography Columns Chromatographic columns can be in any shape that will fit the heating oven. Common forms are U-shaped tube, a W-shaped tube, and a coiled tube. Types of gas chromatography columns: 1- Packed column. 2- Capillary column 1- Typical packed column It is 1 to 2 m long and 0.3 to 0.6 cm in diameter. Short columns can be made of glass, but longer columns may be made of stainless steel so they can be straightened out for filling and packing. 10

11 2- Capillary, or Golay, columns. These are open tubular columns about 0.01 cm in diameter and 20 or more meters long. The liquid stationary phase is coated on and supported by the walls of the tube, where the original capillary columns had a very thin liquid film coated on a smooth metal or glass surface. The columns could be made very long (15 to 35 m) since there was a low pressure drop in the open tube, and they possessed very high separation efficiency (large number or theoretical plates) but they could handle only very small samples, about 10-2 or 10-3 µl of liquid. This necessitated the use of special gas-splitting devices so that only a fraction of the injected sample was introduced into the column. Only the most sensitive detectors could be use, and analysis of trade constituents was difficult. Support-coated open tubular (SCOT) overcome some of the restrictions of the earlier columns, where tubing diameter is 0.05 to 0.15 cm. Capillary columns can provide very high resolution, compared with packed columns. 11

12 Gas Chromatography Capillary, or Golay, columns Videos about Gas Chromatography and columns

13 Gas Chromatography Detectors The Thermal Conductivity Detector 2- Flame Ionization Detector 3- The Flame Thermionic Detector 4- The β-ray (Argon Ionization)Detector 5- The Electron Capture (EC) Detector 6- The Coulometric Detector 13

14 Gas Chromatography Detectors 1- Thermal conductivity (hot wire) detector As a gas is passed over a heated filament wire, the temperature and thus the resistance of the wire will vary according to the thermal conductivity of the gas. The pure carrier is passed over one filament, and the effluent gas containing the sample constituents is passed over another. These filaments are in opposite arms of a Wheatstone bridge circuit that measure the difference in their resistance. So long as there is no sample gas in the effluent, the resistance of wires will be the same, but whenever a sample component is eluted with the carrier gas, a small resistance change will occur in the effluent arm. The change in the resistance, which is proportional to the concentration of the sample component in the carrier gas, is registered on the recorder. Hydrogen and helium carrier gases are preferred with thermal conductivity detectors because they have a very high thermal conductivity compared with most other gases, and so the largest change in the resistance occurs in the presence of sample component gases (helium is preferred for safety reasons). 14

15 Thermal conductivity (hot wire) detector Wheatstone bridge 15

16 2- Flame ionization detector, FID The basis of an extremely sensitive detector is that most organic compounds form ions in a flame. The ions are measured (collected) by a pair of oppositely charged electrodes. The response (number of ions collected) depends on the number of carbon atoms in the sample and on the oxidation state of the carbon. This detector gives excellent sensitivity, permitting measurement of components in the ppb concentration range. The carrier gas is relatively unimportant. He, N 2 and Ar are most frequently employed. The flame ionization detector is insensitive to most inorganic compounds, including water and so aqueous solutions can be injected. 16

17 3- The Flame thermionic detector Is essentially a two stage flame ionization detector, which is designed to give an increased specific response for N and P containing substances. A second flame ionization detector is mounted above the first, with the flame gases from the first passing into the second flame. The column effluent enters the lower flame, which acts as a conventional FID whose response may be recorded. However, if a substance containing N or P is burned in the lower flame, the ions resulting from these greatly increase the volatilization of the alkali metal from the screen. This results in a response that is much greater (at least 100 times) than the response of the lower flame to the N or P. By recording the signals from both flames, one can obtain the usual chromatogram of a FID: a second chromatogram is obtained where the peaks corresponding to the N and P containing compounds are amplified over the others, which will be practically missing. 17

18 4- β-ray or argon ionization detector, AID The sample is ionized by bombardment with β rays from a radioactive source (Ex. Sr-90). The carrier gas is argon and it is excited to a metastable state by the β particles. Argon has an excitation energy of 11.5 ev, which is greater than the ionization potential of most organic compounds, and the sample molecules are ionized when they collide with the excited argon atoms. The ions are detected in the same manner as in the flame ionization detector. This detector is very sensitive but less accurate than others, and the β-ray source is a potential hazard, although with proper shielding, no danger exists. The sensitivity is about 300 times greater than that of the conventional thermal conductivity cell. 18

19 5- The Electron capture (EC) detector Is extremely sensitive for compounds that contain electronegative atoms and is selective for these. It is similar in design to the β-ray detector, except that N 2 or methane doped with Ar is used as the carrier gas. These gases have low excitation energies compared to argon and only compounds that have high electron affinity are ionized, by capturing electrons. The detector cathode consists of a metal foil impregnated with a β- emitting element, usually tritium or Ni-63. A 30% KOH solution is usually used to clean the sources. 19

20 6- The Coulometric detector It was developed in 1960 by Coulson and co-workers. It was originally designed for the selective detection of chloridecontaining substances and is widely used for pesticide analysis. The column effluent is automatically combusted by passing through an oven at 800ºC to give HCl, which is absorbed in a cell containing a solution of silver nitrate. The cell contains a potentiometric silver-indicating electrode that detects changes in the silver concentration as AgCl is precipitated. The variation in potential relative to a reference electrode is amplified and triggers a generating current circuit; the circuit contains a pair of generating electrodes, the anode being a silver wire. 20

21 Detector Application Sensitivity Linearity Remarks 1- Thermal conductivity General, responds to all substances Fair Good, except thermistors at higher temp. Sensitive to temp. and flow changes; concentration sensitive 2- Flame ionization All organic substances; some oxygenated products respond poorly Very good g/ml in carrier gas Excellent, up to 10 6 Requires very stable gas flow; response for water is times weaker than for hydrocarbons; concentration sensitive (organics) 3- Flame thermionic All N and P containing substances Excellent Need recoating of sodium salts on screen; masssensitive 21

22 Detector Application Sensitivity Linearity Remarks 3-Rubidium silicate bead Specific for N and P containing substances. Excellent Mass sensitive 4-Argon ionization (β-ray) All organic substances; with ultraure He carrier gas, also for inorganic and permanent gases. Very good g/ml in carrier gas Good Very sensitive to impurities and water; needs very pure carrier gas; concentration sensitive 5-Electron capture All substances that have affinity to capture electrons; no response for aliphatic and naphthenic hydrocarbons. Excellent for halogen containing substances Poor Very sensitive to impurities and temp. changes; quantitative analysis complicated; concentration sensitive. 22

23 Some Practical Aspects of Gas Chromatography 1- Solid Supports The solid support for a liquid phase should have a high specific surface area that is chemically inert but wettable by the liquid phase. It must be thermally stable and available in uniform sizes. The most commonly used supports are prepared from diatomaceous earth, a spongy siliceous material. They are sold under many different trade names. 2- Coating the Solid Support Column packing support material is coated by mixing with the correct amount of liquid phase dissolved in a low-boiling solvent such as acetone or pentane. After coating, the solvent is evaporated by heating and stirring; last traces may be removed in vacuum and by passing carrier gas through the column. Open tubular columns are coated by slowly passing a dilute solution of the liquid phase through the columns. 23

24 3- Selecting The Liquid Phase There are thousands of commercially available column materials, and several attempts have been made to predict the proper selection of liquid immobile phase without resorting exclusively to trial and error techniques. These methods attempt to group phases according to their retention properties, Ex. According to polarity. Liquid stationary phases are selected based on polarity, determined by the relative polarities of the solutes. The Kovats retention index is useful for identifying a compound from its retention time relative to those of similar compounds in a homologous series (those that differ in the number of carbon atoms in a similar structure, as in alkaline chains). The index I is defined as I, log tr( unk) log t 100 ns,, log tr( n ) log t l r where n s is the number of carbon atoms in the smaller alkane, and n l refers to the larger alkane. The Kovats index for an unknown compound can be compared with catalogued indices on various columns to aid in its identification., r( n ( n s s ) ) 24

25 4- Polar Versus Non-polar Liquids Non-ploar liquid phases are generally nonselective. The reason for this is that there are few forces between the solute and solvent, and so the volatility of the solute is determined primarily by its vapor pressure. Hence, separations will tend to follow the order of the boiling points of the solutes, the lower boiling being eluted first. With polar liquid phases, however, volatility is not so simply determined because of interactions between the solute and the solvent, such as dipole-dipole interactions, hydrogen bonds, and induction forces. 5- Column Length Column lengths of 2 to 3 m are commonly used with packed columns. The resolution generally increases only with the square root of the length of the column. Long columns require high pressure and longer analysis times and are used only when necessary. Separations are generally attempted by selecting columns in lengths of multiples of three, such as 1 m, 3 m and so on. If a separation isnʼt complete in the shorter column, the next longer one is tried. 25

26 5- Temperature Selection The proper temp. selection in gas chromatography is a compromise between several factors. The injection temp. should be relatively high, consistent with thermal stability of the sample, to give the fastest rate of vaporization to get the sample into the column in a small volume; decreased spreading and increased resolution result. Too high an injection temp., though, will tend to degrade the rubber septum and cause dirtying of the injection port. The column temp. is a compromise between speed, sensitivity, and resolution. At high column temp., the sample components spend most of their time in the gas phase and so they are eluted quickly, but resolution is poor. At low temp., they spend more time in the the stationary phase and elute slowly; resolution is increased but sensitivity is decreased due to increased spreading of peaks. The detector temp. must be high enough to prevent condensation of the sample components. The sensitivity of the thermal conductivity detector decreases as the temp. is increased and so its temp. is kept at the minimum required. Some separations can be facilitated by temperature programming. 26

27 Quantitative Measurement of Chromatographic Peaks We mentioned that the concentrations of eluted solutes are proportional to the areas under the recorded peaks. A variety of methods can be used to estimate the areas, including mechanical or electronic integrators (as a part of the recorder). We have mentioned the possibility of measuring the peaks height to construct a calibration curve. The linearity of a calibration curve always be established. The method of Standard Additions is a useful technique for calibrating, especially for occasional samples. One or more aliquots of the sample are spiked with a known concentration of standard, and the increase in peak area is proportional to the added standard. This method has the advantage of verifying that the retention time of the unknown analyte is the same as that of the standard. A more important method of quantitative analysis is the use of Internal Standards. Here, the sample and standard are spiked with an equal amount of a solute whose retention time is near that of the analyte. The ratio of the area of the standard or analyte to that of the internal standard is used to prepare the calibration curve and determine the unknown concentration. 27

28 17.9 GAS CHROMATOGRAPHY MASS SPECTROMETRY The appearance of chromatographic peak at a particular retention time suggests but dose not guarantee the presence of a particular compound. Spectral information, such as infrared or ultraviolet spectrometry, may be sought. A very powerful tool is the combination of gas chromatography with mass spectrometry, a technique known as gas chromatography mass spectrometry (GC-MS). Mass spectrometry is a sophisticated instrumental technique that produces, separate and detectors ions in gas phase. The basic components of a mass spectrometer are shown in Fig A sample with a moderately high vapor pressure is introduced in an inlet system, operated under vacuum (10-4 to 10-7 torr) and at high temp. (up to 300ºC). It vaporizes and is carried to the ionization source.. Analyte molecules are typically neutral and must be ionized. This is accomplished by various means but typically is done by bombarding the sample with high-energy electrons in an electron-impact source. 28

29 The ions are separated in the spectrometer by being accelerated through a mass separator. Separation is actually accomplished based on the mass to charge (m/e) ratio of the ions. The resolution is more limited than with other mass analyzers, but this is not usually a problem when combined with the gas chromatography information. The separated ions are detected by means of an electron multiplier, which is similar in design to photomultiplier tubes. Detection sensitivities at the nanogram level are common. The effluent from a gas chromatography may be connected to the sample inlet system of a mass spectrometer, forming a GC-MS system. The mass spectrometer then serves as the GC detector with high sensitivity and selectivity. 29

30 The mass spectrometer may be operated in various modes: 1- In the total ion current (TIC) monitoring mode, it sums the currents from all fragment ions as a molecule (or molecules) in a GC peak passes through the detector, to provide a conventional looking gas chromatogram of several GC peaks. 2- In the selective ion mode, a specific (m/e) ratio is monitored, and so only molecules that give a molecular or fragment ion at that ratio will be sensed. The mass spectrum of each molecule detected is stored in the systemʼs computer, and so the mass spectrum corresponding to a given GC peak can be read out. The mass spectrum is generally characteristic for a given compound (if only one compound is present under the GC peak), giving a certain fingerprint of peaks at various m/e ratios. 30

Chapter 31 Gas Chromatography. Carrier Gas System

Chapter 31 Gas Chromatography. Carrier Gas System Chapter 31 Gas Chromatography GAS-LIQUID CHROMATOGRAPHY In gas chromatography, the components of a vaporized sample are fractionated as a consequence of being partitioned between a mobile gaseous phase

More information

Chapter 27: Gas Chromatography

Chapter 27: Gas Chromatography Chapter 27: Gas Chromatography Gas Chromatography Mobile phase (carrier gas): gas (He, N 2, H 2 ) - do not interact with analytes - only transport the analyte through the column Analyte: volatile liquid

More information

2401 Gas (liquid) Chromatography

2401 Gas (liquid) Chromatography 2401 Gas (liquid) Chromatography Chromatography Scheme Gas chromatography - specifically gas-liquid chromatography - involves a sample being vaporized and injected onto the head of the chromatographic

More information

Chromatography. Gas Chromatography

Chromatography. Gas Chromatography Chromatography Chromatography is essentially the separation of a mixture into its component parts for qualitative and quantitative analysis. The basis of separation is the partitioning of the analyte mixture

More information

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY Chapter 23. Gas Chromatography What did they eat in the year 1,000? GC of Cholesterol and other lipids extracted from

More information

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5 Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH 5730-6730 Analysis Topic 5 Chromatography! Group of separation techniques based on partitioning (mobile phase/stationary phase). Two immiscible

More information

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed Gas Chromatography (GC) In gas chromatography, the sample is vaporized and injected onto the head of a chromatographic

More information

Gas Chromatography. Introduction

Gas Chromatography. Introduction Gas Chromatography Introduction 1.) Gas Chromatography Mobile phase (carrier gas) is a gas - Usually N 2, He, Ar and maybe H 2 - Mobile phase in liquid chromatography is a liquid Requires analyte to be

More information

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas GAS CHROMATOGRAPHY Mobile phase is a gas! Stationary phase could be anything but a gas Gas Chromatography (GC) GC is currently one of the most popular methods for separating and analyzing compounds. This

More information

Gas Chromatography (GC)

Gas Chromatography (GC) Gas Chromatography (GC) Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh 11541 Saudi Arabia Office: AA53

More information

Gas chromatography. Advantages of GC. Disadvantages of GC

Gas chromatography. Advantages of GC. Disadvantages of GC Advantages of GC Gas chromatography Fast analysis, typically minutes Effi cient, providing high resolution Sensitive, easily detecting ppm and often ppb Nondestructive, making possible on - line coupling;

More information

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC Gas Chromatography Gas Chromatography Presented By Mr. Venkateswarlu Mpharm KTPC What is Gas Chromatography? It is also known as Gas-Liquid Chromatography (GLC) GAS CHROMATOGRAPHY Separation of gaseous

More information

Skoog/Holler/Crouch Chapter 26 Principles of Instrumental Analysis, 6th ed. CHAPTER 26

Skoog/Holler/Crouch Chapter 26 Principles of Instrumental Analysis, 6th ed. CHAPTER 26 Skoog/Holler/Crouch Chapter 26 Principles of Instrumental Analysis, 6th ed. Instructor s Manual CHAPTE 26 26-1. (a) Elution is a process in which species are washed through a chromatographic column by

More information

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

CH 2252 Instrumental Methods of Analysis Unit V  Gas Chromatography.  M. Subramanian CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography M. Subramanian Assistant Professor Department of Chemical Engineering Sri Sivasubramaniya Nadar College of Engineering Kalavakkam 603

More information

7 INSTRUMENTAL CHROMATOGRAPHY

7 INSTRUMENTAL CHROMATOGRAPHY 7 INSTRUMENTAL CHROMATOGRAPHY 7.1 Introduction There are two forms of chromatography, very widely used in analytical laboratories, which rely on electronic control of the process and detection of the species.

More information

Disadvantage: Destructive Technique once analyzed by GC, the sample is lost

Disadvantage: Destructive Technique once analyzed by GC, the sample is lost Gas Chromatography Like other methods of chromatography, a partitioning of molecules must occur between the stationary phase and the mobile phases in order to achieve separation. This is the same equilibrium

More information

GC Instruments. GC Instruments - Sample Introduction

GC Instruments. GC Instruments - Sample Introduction GC Instruments 1 Fairly simple instrumentation Maintaining constant average pressure is important! Pressure controls flow rate T influences retention (k ) Flow rate monitoring Changing flow rate changes

More information

CHAPTER 6 GAS CHROMATOGRAPHY

CHAPTER 6 GAS CHROMATOGRAPHY CHAPTER 6 GAS CHROMATOGRAPHY Expected Outcomes Explain the principles of gas chromatography Able to state the function of each components of GC instrumentation Able to state the applications of GC 6.1

More information

Gas Chromatography. A schematic diagram of a gas chromatograph

Gas Chromatography. A schematic diagram of a gas chromatograph Gas Chromatography In gas liquid chromatography (GLC) partition of solutes occurs between a mobile gas phase (the "carrier gas") and a stationary liquid phase present in the column. The gas-phase concentration

More information

Biochemistry. Biochemical Techniques. 12 Gas Liquid Chromatography

Biochemistry. Biochemical Techniques. 12 Gas Liquid Chromatography Description of Module Subject Name Paper Name 12 Module Name/Title 12 Gas - liquid Chromatography 1. Objectives 1.1 To understand principle of Gas Liquid Chromatography 1.2 To explain the different components

More information

Gas Chromatography. Rosa Yu, David Reckhow CEE772 Instrumental Methods in Environmental Analysis CEE 772 #16 2

Gas Chromatography. Rosa Yu, David Reckhow CEE772 Instrumental Methods in Environmental Analysis CEE 772 #16 2 Print version Gas Chromatography Rosa Yu, David Reckhow CEE772 Instrumental Methods in Environmental Analysis CEE 772 #16 1 Contents The primary components to a GC system 1. Carrier Gas System (including

More information

Chromatography and Functional Group Analysis

Chromatography and Functional Group Analysis Chromatography Chromatography separates individual substances from a mixture. - to find out how many components there are - to match the components with known reference materials - to use additional analytical

More information

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications Chapter 27: Gas Chromatography Principles Instrumentation Detectors Columns and Stationary Phases Applications GC-MS Schematic Interface less critical for capillary columns Several types of Mass Specs

More information

Gas Chromatography. Chromatography Laboratory Course. Dr. Christian Jungnickel Chromatography Course GC September 2005

Gas Chromatography. Chromatography Laboratory Course. Dr. Christian Jungnickel Chromatography Course GC September 2005 Gas Chromatography Chromatography Laboratory Course The laboratory course experiments General Aim: Gain general experience using a GC Constant Injection technique Temperature variations Qualitative and

More information

Gas Chromatography notes

Gas Chromatography notes Gas Chromatography notes 1. Here is some terminology related to this experiment: Chromatography is a technique in which compounds to be separated are distributed between a mobile phase and a stationary

More information

High Pressure/Performance Liquid Chromatography (HPLC)

High Pressure/Performance Liquid Chromatography (HPLC) High Pressure/Performance Liquid Chromatography (HPLC) High Performance Liquid Chromatography (HPLC) is a form of column chromatography that pumps a sample mixture or analyte in a solvent (known as the

More information

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Chemistry Instrumental Analysis Lecture 27. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 27 Gas Chromatography Introduction GC covers all chromatographic methods in which the mobile phase is gas. It may involve either a solid stationary phase (GSC)

More information

Gas Chromatography. Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid

Gas Chromatography. Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid Gas Chromatography Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid Principles Instrumentation Applications 18-1 Retention Volumes Volumes rather than times

More information

Chemistry Gas Chromatography: Separation of Volatile Organics

Chemistry Gas Chromatography: Separation of Volatile Organics Chemistry 3200 Gas chromatography (GC) is an instrumental method for separating volatile compounds in a mixture. A small sample of the mixture is injected onto one end of a column housed in an oven. The

More information

Analytical Chemistry

Analytical Chemistry Analytical Chemistry Chromatographic Separations KAM021 2016 Dr. A. Jesorka, 6112, aldo@chalmers.se Introduction to Chromatographic Separations Theory of Separations -Chromatography Terms Summary: Chromatography

More information

Ch24. Gas Chromatography (GC)

Ch24. Gas Chromatography (GC) Ch24. Gas Chromatography (GC) 24.1 What did they eat in the year 1000? From 13 C content of cholesterol in ancient bone 13 C : 1.1%, 12 C: 98.9% 13 C/ 12 C ratio types of plants Bones of 50 people in Barton-on-Humber

More information

Chapter 11 Conventional Gas Chromatography

Chapter 11 Conventional Gas Chromatography Chapter 11 Conventional Gas Chromatography Gas Chromatography GC is the first instrumental chromatographic method developed commercially It is relatively easy to introduce a stable flow and pressure for

More information

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure. High performance liquid chromatography (HPLC) is a much more sensitive and useful technique than paper and thin layer chromatography. The instrument used for HPLC is called a high performance liquid chromatograph.

More information

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC CHROMATOGRAPHY Laboratory technique for the Separation of mixtures Chroma -"color" and graphein

More information

Experiment 6 Simple and Fractional Distillation

Experiment 6 Simple and Fractional Distillation Experiment 6 Simple and Fractional Distillation Vapor Pressure vs Temperature of Water Vapor Pressure vs Temperature of Water 25 Vapor Pressure vs Temperature of Water 25 Vapor Pressure (kpa) (kpa) 2 2

More information

10/27/10. Chapter 27. Injector typically 50 C hotter than oven

10/27/10. Chapter 27. Injector typically 50 C hotter than oven Sample and solvent are vaporized onto the head of a column Vaporized solvent and solute are carried through the column by an inert gas (mobile phase) The mobile phase does not interact with compounds of

More information

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments. Chromatography Primer Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments. At its heart, chromatography is a technique

More information

Introduction to Gas Chromatography

Introduction to Gas Chromatography Introduction to Gas Chromatography 31-1 Objectives To know what is chromatography To understand the mechanism of compound separation To know the basic of gas chromatography system 31-2 Chromatography Definition

More information

Volatile organic compounds (VOCs):

Volatile organic compounds (VOCs): Volatile organic compounds (VOCs): Organic chemicals with a high vapour pressure at room temperature. High vapour pressure results from a low boiling point. The World Health Organization (WHO) defined

More information

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Chemistry Instrumental Analysis Lecture 34. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 34 From molecular to elemental analysis there are three major techniques used for elemental analysis: Optical spectrometry Mass spectrometry X-ray spectrometry

More information

G a s C h r o m a t o g r a p h y Determination of Ethanol in Wine by Head-Space Gas Chromatography

G a s C h r o m a t o g r a p h y Determination of Ethanol in Wine by Head-Space Gas Chromatography G a s C h r o m a t o g r a p h y Determination of Ethanol in Wine by Head-Space Gas Chromatography Pibulsongkram Rajabhat University Department of Agro-Industry Faculty of Food and Agricultural Technology

More information

Principles of Gas- Chromatography (GC)

Principles of Gas- Chromatography (GC) Principles of Gas- Chromatography (GC) Mohammed N. Sabir January 2017 10-Jan-17 1 GC is a chromatographic technique utilizes gas as the mobile phase which is usually an inert gas (Hydrogen, Helium, Nitrogen

More information

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography Emqal module: M0925 - Quality parameters and optimization in is a separation technique used for quantification of mixtures of analytes Svein.mjos@kj.uib.no Exercises and lectures can be found at www.chrombox.org/emq

More information

Chapter 1. Chromatography. Abdul Muttaleb Jaber

Chapter 1. Chromatography. Abdul Muttaleb Jaber Chapter 1 Chromatography Abdul Muttaleb Jaber What is Chromatography? Chromatography is a physico-chemical process that belongs to fractionation methods same as distillation, crystallization or fractionated

More information

Lab 3 Guide: Gas Chromatography (GC) (Sept 8-14)

Lab 3 Guide: Gas Chromatography (GC) (Sept 8-14) Lab 3 Guide: Gas Chromatography (GC) (Sept 8-14) How GC works The Basic Idea Gas chromatography (GC) is mainly used for the qualitative analysis of samples: it answers the question What chemicals are present

More information

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011 ?? Kβ? Page 1 Typical GC System Gas supply Injector Detector Data handling GAS Column Oven Page 2 CARRIER GAS Carries the solutes down the column Selection and velocity influences efficiency and retention

More information

GAS CHROMATOGRAPHY (GC)

GAS CHROMATOGRAPHY (GC) GAS CHROMATOGRAPHY (GC) Pre-Lab Questions Questions are to be answered before the beginning of the laboratory. The answers are due at the beginning of each experiment (the questions are for credit and

More information

https://www.chemicool.com/definition/chromatography.html

https://www.chemicool.com/definition/chromatography.html CHROMATOGRAPHY 1 Chromatography - a physical method of mixture separation in which the components to be separated are distributed between two phases, one of which is stationary (stationary phase) while

More information

Volumetric Analysis. Quantitative analysis answers the second question

Volumetric Analysis. Quantitative analysis answers the second question Volumetric Analysis Volumetric analysis is a form of quantitative analysis involving the measuring of volumes of reacting solutions, it involves the use of titrations. When buying food we often have two

More information

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers. CHEM 322 Name Fall 2012 Due In Class Friday, Oct. 19 Complete the following on separate paper. Show your work and clearly identify your answers. General Separations 1. Describe the relative contributions

More information

DATES: LAB: Liquid Chromatography Separation of Grape Kool-Aid

DATES: LAB: Liquid Chromatography Separation of Grape Kool-Aid NAME: AP CHEMISTRY DATES: LAB: Liquid Chromatography Separation of Grape Kool-Aid PURPOSE There are a number of analytical techniques used to separate components of a mixture, or solution. They include

More information

Questions on Instrumental Methods of Analysis

Questions on Instrumental Methods of Analysis Questions on Instrumental Methods of Analysis 1. Which one of the following techniques can be used for the detection in a liquid chromatograph? a. Ultraviolet absorbance or refractive index measurement.

More information

Experiment 3: Analysis of Unknown Hydrocarbons by GC, NMR, and Chemical Tests for Unsaturation and Aromaticity

Experiment 3: Analysis of Unknown Hydrocarbons by GC, NMR, and Chemical Tests for Unsaturation and Aromaticity Experiment 3: Analysis of Unknown Hydrocarbons by GC, NMR, and Chemical Tests for Unsaturation and Aromaticity In this experiment you will be determining the structures and checking the purity of the hydrocarbon

More information

Understanding Gas Chromatography

Understanding Gas Chromatography Understanding Gas Chromatography What is Really Going on Inside the Box? Simon Jones GC Applications Engineer Page 1 Group/Presentation Title Month ##, 200X ?? K? Page 2 Typical GC System Gas supply Injector

More information

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction.

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction. LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT Thomas Wenzel, Bates College In-class Problem Set Extraction Problem #1 1. Devise a scheme to be able to isolate organic acids, bases

More information

Principles of Instrumental Analysis

Principles of Instrumental Analysis Principles of Instrumental Analysis Chapter 27 Gas Chromatography Gas Chromatography (GC): vaporized analytes (solutes) are partitioned between a mobile gaseous phase and a liquid or a solid stationary

More information

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Chemistry Instrumental Analysis Lecture 28. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 28 Two types in general use: -packed (stationary phase) -open tubular or capillary determine selectivity and efficiency of the sample. Column Materials Column

More information

Introduction to Capillary GC

Introduction to Capillary GC ?? Kβ? Page 1 Typical GC System Gas supply Injector Detector Data handling GAS Column Oven Page 2 CARRIER GAS Carries the solutes down the column Selection and velocity influences efficiency and retention

More information

Spectroscopy and Chromatography

Spectroscopy and Chromatography Spectroscopy and Chromatography Introduction Visible light is one very small part of the electromagnetic spectrum. The different properties of the various types of radiation depend upon their wavelength.

More information

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS International Gas Union Research Conference 14 THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS Main author Hironori IMANISHI Tokyo Gas Co., Ltd. JAPAN himanishi@tokyo-.co.jp

More information

Title Experiment 7: Gas Chromatography and Mass Spectrometry: Fuel Analysis

Title Experiment 7: Gas Chromatography and Mass Spectrometry: Fuel Analysis Title Experiment 7: Gas Chromatography and Mass Spectrometry: Fuel Analysis Name Manraj Gill (Partner: Tanner Adams, Lab Section: 102) Introduction In this experiment, we use chromatography and mass spectrometry

More information

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. Jaap de Zeeuw, Ron Stricek and Gary Stidsen Restek Corp Bellefonte, USA To analyze basic compounds at

More information

Chromatographic Separation

Chromatographic Separation What is? is the ability to separate molecules using partitioning characteristics of molecule to remain in a stationary phase versus a mobile phase. Once a molecule is separated from the mixture, it can

More information

Chapter content. Reference

Chapter content. Reference Chapter 7 HPLC Instrumental Analysis Rezaul Karim Environmental Science and Technology Jessore University of Science and Technology Chapter content Liquid Chromatography (LC); Scope; Principles Instrumentation;

More information

Luminescence transitions. Fluorescence spectroscopy

Luminescence transitions. Fluorescence spectroscopy Luminescence transitions Fluorescence spectroscopy Advantages: High sensitivity (single molecule detection!) Measuring increment in signal against a dark (zero) background Emission is proportional to excitation

More information

Analytical techniques: Environmental samples. Lecture 2 Universidade do Algarve

Analytical techniques: Environmental samples. Lecture 2 Universidade do Algarve Analytical techniques: Environmental samples Lecture 2 Universidade do Algarve Terms, definitions & applications Difference between technique and method: Analytical technique: Fundamental scientific application

More information

Physical Separations and Chromatography

Physical Separations and Chromatography Lab #5A & B: Physical Separations and Chromatography Individual Objectives: At the end of these experiments you should be able to: Ø Distinguish between Rf and tr; chromatograph and chromatogram; adsorption

More information

Experiment 8: Chlorination of 1-Chlorobutane

Experiment 8: Chlorination of 1-Chlorobutane 1 Experiment 8: Chlorination of 1-Chlorobutane Alkanes contain only nonpolar carbon-hydrogen and carbon-carbon single bonds, which makes them unreactive toward most acidic and basic reagents. They can,

More information

Introduction to Chromatographic Separations

Introduction to Chromatographic Separations Introduction to Chromatographic Separations Analysis of complex samples usually involves previous separation prior to compound determination. Two main separation methods instrumentation are available:

More information

1. Carrier gas supply. - Flow rate measurement

1. Carrier gas supply. - Flow rate measurement Chapter 27 Gas chromatography Gas Chromatography - The components of a vaporized sample are separated as a consequence of being partitioned between a mobile gaseous phase and a liquid or a solid stationary

More information

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY Page 1 of 13 CIPAC/4105/R GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY Prepared for CIPAC by Dr M J Tandy*, P M Clarke and B White (UK) The rapid

More information

Chromatography and other Separation Methods

Chromatography and other Separation Methods Chromatography and other Separation Methods Probably the most powerful class of modern analytical methods for analyzing mixture of components---and even for detecting a single component in a complex mixture!

More information

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds Atmospheric Analysis Gases Sampling and analysis of gaseous compounds Introduction - External environment (ambient air) ; global warming, acid rain, introduction of pollutants, etc - Internal environment

More information

Chemistry 283g- Experiment 4

Chemistry 283g- Experiment 4 EXPEIMENT 4: Alkenes: Preparations and eactions elevant sections in the text: Fox & Whitesell, 3 rd Ed. Elimination eactions of Alcohols: pg. 426-428, 431-432 Electrophilic Addition to Alkenes: pg. 484-488,

More information

/Chapter 27.ppt

/Chapter 27.ppt Information given in these slides are, either in part or all, recollection from the followings: http://bionmr.unl.edu/courses/chem421-821/lectures/chapter-2... http://faculty.atu.edu/abhuiyan/course/chem

More information

Chapter 26. An Introduction to Chromatographic Separations. Chromatography

Chapter 26. An Introduction to Chromatographic Separations. Chromatography Chapter 26 An Introduction to Chromatographic Separations Chromatography 1 Chromatography-Model as Extraction Chromatography-Model as Extraction 2 Chromatography Planar Chromatography-Types paper chromatography

More information

GC Instruments. GC Instruments - Columns

GC Instruments. GC Instruments - Columns GC Instruments 1 Fairly simple instrumentation Maintaining constant average pressure is important! Pressure controls flow rate T influences retention (k ) Flow rate monitoring Changing flow rate changes

More information

Gas Chromatography (GC)

Gas Chromatography (GC) Gas Chromatography (GC) Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh 11451 Saudi Arabia Building:

More information

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai 303351 Instrumental Analysis Mass Spectrometry Lecturer:! Somsak Sirichai Mass Spectrometry What is Mass spectrometry (MS)? An analytic method that employs ionization and mass analysis of compounds in

More information

Lecture 15: Introduction to mass spectrometry-i

Lecture 15: Introduction to mass spectrometry-i Lecture 15: Introduction to mass spectrometry-i Mass spectrometry (MS) is an analytical technique that measures the mass/charge ratio of charged particles in vacuum. Mass spectrometry can determine masse/charge

More information

CHEM 429 / 529 Chemical Separation Techniques

CHEM 429 / 529 Chemical Separation Techniques CHEM 429 / 529 Chemical Separation Techniques Robert E. Synovec, Professor Department of Chemistry University of Washington Lecture 1 Course Introduction Goal Chromatography and Related Techniques Obtain

More information

Instrumental Chemical Analysis

Instrumental Chemical Analysis L2 Page1 Instrumental Chemical Analysis Chromatography (General aspects of chromatography) Dr. Ahmad Najjar Philadelphia University Faculty of Pharmacy Department of Pharmaceutical Sciences 2 nd semester,

More information

Thin Layer Chromatography

Thin Layer Chromatography Thin Layer Chromatography Thin-layer chromatography involves the same principles as column chromatography, it also is a form of solid-liquid adsorption chromatography. In this case, however, the solid

More information

Name Period Date. Lab 10: Paper Chromatography

Name Period Date. Lab 10: Paper Chromatography Name Period Date Lab 10: Paper Chromatography Objectives Known and unknown solutions of the metal ions Fe +, Cu 2+ and Ni 2+ will be analyzed using paper chromatography. An unknown solution containing

More information

Chem 321 Name Answer Key D. Miller

Chem 321 Name Answer Key D. Miller 1. For a reversed-phase chromatography experiment, it is noted that the retention time of an analyte decreases as the percent of acetonitrile (CH 3 CN) increases in a CH 3 CN/H 2 O mobile phase. Explain

More information

Chromatography Outline

Chromatography Outline Chem 2001 Summer 2004 Outline What is? The Chromatogram Optimization of Column Performance Why Do Bands Spread? Gas High-Performance Liquid Ion-Exchange 2 What is? In chromatography, separation is achieved

More information

Technical know-how in thermal analysis measurement

Technical know-how in thermal analysis measurement Technical articles Technical know-how in thermal analysis measurement Evolved gas analysis by thermogravimetry-differential thermal analysis-mass spectrometry (TG-DTA-MS) technique Kazuko Motomura* and

More information

Introduction to GC/MS

Introduction to GC/MS Why Mass Spectrometry? Introduction to GC/MS A powerful analytical technique used to: 1.Identify unknown compounds 2. Quantify known materials down to trace levels 3. Elucidate the structure of molecules

More information

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur 603 203 DEPARTMENT OF ELECTRONICS AND INSTRUMENTATION ENGINEERING QUESTION BANK V SEMESTER EI6501 Analytical Instruments Regulation 2013 Academic

More information

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis Watch this lesson online: https://edrolo.com.au/vce/subjects/chemistry/vce-chemistry/aos-1-chemical-analysis/chromatography-hplc-glc/column-chromatography/#watch CHEMISTRY Unit 3, Area of Study 1: Chemical

More information

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25) Gas Chromatography NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25) The Non-Methane Organic Compounds (NMOC) Analyzer is a gas chromatograph configured for analyzing gaseous samples for total organic

More information

Chem 454 instrumental Analysis Exam 1 February 6 th, 2008

Chem 454 instrumental Analysis Exam 1 February 6 th, 2008 Chem 454 instrumental Analysis Exam 1 February 6 th, 2008 1 Name: 1] A glass electrode was immersed into a solution of ph 4.33 gave a response of 677.1 mv. This electrode was used to measure a sample solution

More information

Introduction and Principles of Gas Chromatography

Introduction and Principles of Gas Chromatography Introduction and Principles of Gas Chromatography Jaap de Zeeuw Restek, Middelburg, The Netherlands Jaap.dezeeuw@restek.com Definition and Uses of Gas Chromatography GC Components and Types of Columns

More information

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for? Chromatography- Separation of mixtures CHEM 212 What is solvent extraction and what is it commonly used for? How does solvent extraction work? Write the partitioning coefficient for the following reaction:

More information

Introduction. Chapter 1. Learning Objectives

Introduction. Chapter 1. Learning Objectives Chapter 1 Introduction Learning Objectives To understand the need to interface liquid chromatography and mass spectrometry. To understand the requirements of an interface between liquid chromatography

More information

Instrumental Analysis II Course Code: CH3109. Chromatographic &Thermal Methods of Analysis Part 1: General Introduction. Prof. Tarek A.

Instrumental Analysis II Course Code: CH3109. Chromatographic &Thermal Methods of Analysis Part 1: General Introduction. Prof. Tarek A. Instrumental Analysis II Course Code: CH3109 Chromatographic &Thermal Methods of Analysis Part 1: General Introduction Prof. Tarek A. Fayed What is chemical analysis? Qualitative analysis (1) Chemical

More information

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION METHOD 80 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION 1.0 SCOPE AND APPLICATION 1.1 Method 80 may be used to determine the concentration of acetonitrile (CAS No. 75-05-8) in aqueous

More information

Chromatography. Chromatography is a combination of two words; * Chromo Meaning color * Graphy representation of something on paper (writing)

Chromatography. Chromatography is a combination of two words; * Chromo Meaning color * Graphy representation of something on paper (writing) Chromatography Chromatography is a combination of two words; * Chromo Meaning color * Graphy representation of something on paper (writing) Invention of Chromatography Mikhail Tswett invented chromatography

More information

Gas Chromatography. 1. Experiment Category: 2. Experiment Name: 3. Date and Issue number: 4. Instructor Name: 5. Institution: Ain Shams University

Gas Chromatography. 1. Experiment Category: 2. Experiment Name: 3. Date and Issue number: 4. Instructor Name: 5. Institution: Ain Shams University Project Title: e-laboratories for Gas chromatography 1. Experiment Category: Chemistry >> chromatography 2. Experiment Name: Gas Chromatography 3. Date and Issue number: 4. Instructor Name: 5. Institution:

More information

HPLC Workshop 16 June 2009 What does this do? Chromatography Theory Review Several chromatographic techniques Even though each method utilizes different techniques to separate compounds, the principles

More information