Long and Analysis Reports

Size: px
Start display at page:

Download "Long and Analysis Reports"

Transcription

1 LONG REPORT FORMAT AND GRADING RUBRIC Long and Analysis Reports 8 Long and Analysis Report Format and Grading Rubrics Analsis Reports will be collected for the HPLC and Long Reports for the FAAS experiments. At instructor discretion, FAAS Reports will have 8 sections with the following weights: 1 Cover page 02 2 Abstract 13 3 Introduction 10 4 Experimental 10 5 Analysis, Results and Discussion 20 6 References and Scholarship 10 7 Figures and Tables 20 8 Appendix with calculations 15 Total 100 points Use this format for both reports. HPLC and FAAS Reports will have 4 sections with the following weights. See below for more detailed explanation of the sections. 1 Cover page 02 2 Abstract (reporting quant and qual results) 13 3 Analysis and Results Section 20 4 Figures and Tables 20 Calibration curves Retention maps Table of results 5 Appendix with calculations 15 Total 70 points 50

2 LONG REPORT FORMAT AND GRADING RUBRIC Each section will be scored according to both written expression and scientific content. The following criteria will be applied to the evaluation of written expression: Grade Level A B C D F English Composition Quality / per paragraph Clear, concise, and reflecting excellent understanding of subject. Clear, few superfluous words, reflecting good understanding of subject. Basic point is understandable, but reader must work to figure it out. Paragraphs makes at least one point amid superfluous words/sentences. Point very unclear or wording illogical. Grade Grammar Mistakes / Page or Section if section shorter than 1 page. A 0-1 B 2-4 C 5-7 D 8-11 F

3 LONG REPORT FORMAT AND GRADING RUBRIC Scientific content and format are summarized below: General remarks: 1. Standard deviations and confidence intervals based on small data sets have two significant figures not more. The last sig fig in the std dev is the last sig fig reported in the average or calculated answer. Example: 12.23±0.55 = correct 12.23±1.23 = incorrect! should be 12.2±1.2 (last digit = 0.1) 12.2±0.23 = incorrect! should be 12.23±0.23 (last digit = 0.01) 1. Cover page: 1.1. Title 1.2. Your name 1.3. Your partner s name 1.4. Course 1.5. Professor Terrill 1.6. Date Submitted The boxes below contain some key report elements that I use to score the reports! 2. Abstract: Very, very brief and clear summary of the experiments and results. In a few short sentences convey (a) what was done (measured) and (b) using what method (HPLC or FAAS) and (c) with what crucial conditions and (d) sample preparation and (d) the final results w/ estimated errors (σ and 95% CI) (c). If they were not included in the above, give those few crucial details (λ, stationary phase, mobile phase) that are critical to reproducing the work by an expert and (d) conclusions regarding null hypothesis and bias if possible Length: Approximately words Concise description of what was measured and how (method name) Results clearly summarized Zn amt ± error Fe amt ± error units of mg/can or mg/pill 2.4. If data quality support conclusions: Evidence of bias wrt validation? Evidence of bias wrt expected value? Evidence of bias from sample to sample? 2.5. Concise description of how measurements made w crucial details only: HPLC mobile / stationary phases detection limit / wavelength FAAS flame type (air / C 2 H 2 ) detection limit / wavelength 2.6. Negatives: Too much detail (raw signals, dilutions, etc.) Conversational tone or unnecessary words or phrases Speculation about results 52

4 LONG REPORT FORMAT AND GRADING RUBRIC 3. Introduction: The tone of an analytical chemistry report where the instrumental method is being developed to solve a particular problem is typically like this: Compound x is of interest because The instrumental method yyy is appropriate to this analysis because In these experiments x was measured (diet Coke / Centrum Silver ) with a vvv instrument using zzz conditions. The results were excellent/good/fair/poor (perhaps why) Length: Approximately words Very short description of the analytes what they are why they are there and why it is important to quantify them 3.3. Discussion of the instrumental method how the method works, focusing on the principles of the detection and/or separation e.g. the absorption of light by gas phase atomic analytes or the partitioning of analytes from a solution (mobile phase) to a stationary phase why it is appropriate to the problem of measuring this analyte in this matrix what aspects of this instrumental method make it sensitive or selective for the analytes of interest possible interferences / problems and how they are controlled or not description of experimental parameters that are important to this particular analysis, influence the performance of the instrument and why e.g. flame stoichiometry or mobile phase composition, wavelength etc. 4. Experimental Methods 4.1. Length: Approximately words Instruments and Materials: List the name and manufacturer of the instruments you used, e.g. Unicam 929 AA spectrometer Include the important instrument specific parameters column type (stationary phase) flame type, wavelengths etc Reagents used, including the water. It is acceptable to indicate that these were obtained from the SJSU Chemistry Service Center, but indicate the manufacturer and the purity where available (e.g. with the concentrated acids since they contain trace metal impurities). 5. Procedure: Sample, standard, validation, 5.1. Length: Approximately preparations. words. Keep it short. I don t need to know every step! Use tables! UV-Vis experiment (HPLC) 5.2. In this section, describe what you Implementation of HPLC flow rate, did in such a way that another pressure, injection volume, injection chemist could look at it and time, sample vials, injection order. reproduce your work. It is not a set of step-by-step instructions but rather a concise description of what you 53

5 LONG REPORT FORMAT AND GRADING RUBRIC actually did. For example: The calibration primary standard ( PPM) was prepared by dissolving g of Co metal in yy ml of HNO 3 (conc.), and diluting to L with distilled water. Validation standards were similarly prepared to yield two, 500mL solutions of qq and zz PPM The working standards were prepared by serial dilution of the standards in the following way The concentrations are listed in Table 1. The standard concentrations and signals will be tabulated in the results section see the below for details. Important experimental parameters used should be mentioned here. For example For the FAAS analysis, an Air-acetylene flame source, hollow cathode lamp radiation source and a wavelength of xxx.x nm were employed. A common mistake is to claim that your standards are 10 ppm when they are actually 10.1 because the primary calibration standard was based on 101 mg instead of Analysis, Results and Discussion: Describe the results of your measurements in words and figures Length: Approximately words Refer to the various numbered figures (spectra, chromatograms or graphs) and tables in turn and discuss the results. Where possible, you explain (a) why the results are what they are and (b) what they mean and (c) how you used them Note UV absorbance spectra of CF and BA and relevance to HPLC detection Note retention times for the HPLC experiment. UV-Vis results, calibration, linear regression and error calculations, problems in chromatogram or with spectrometer, Sample-sample variation versus standard deviation estimate based on calibration curve. Agreement with expectation is difference between expected value and measured value larger than the standard deviation (sample and validation results)? What does this mean? Comments on chromatogram elution order, resolution etc Make a table, following the below format, of absorbance and concentration values including the appropriate uncertainties for all of your samples, calibration and validation standards. I include an example for the FAAS experiment below: 54

6 LONG REPORT FORMAT AND GRADING RUBRIC For HPLC these are the peak integrals. Table 1: Absorbance Data: Fe concentrations and amounts. Abs ± std dev PPM prepared Blank ± Std ± Std ± Std ± Std ± Std ± There is usually no std dev on this number except for PE FAAS.. For the HPLC there is no validation (QC) standard, so skip this. Abs ± std dev PPM expected PPM calculated Validation ± ± ± Yes Validation ± ± ± No Δ% bias * For the HPLC you may have only one sample so thiese last two lines can be skipped.. mg. tab -1 expected mg. tab -1 calculated Sample ± ± ±2-16 Yes Sample ± ± ±3-22 Yes Smpl 1 to ± ± ±2 6 No For the HPLC did not do any spike recovery so this can be skipped.. mg from sample mg from spike total mg expected total mg found Spike Rec % Spike Rec. Fe 0.202± ± Yes Spike Rec. Zn 0.124± ± No Significant? I define bias here as the likelihood that the difference is too large to be due to random fluctuation i.e. the likelihood that the difference is real. To get this number, one calculates the t-value and uses the t-table to find the corresponding confidence interval. Please note that the bias * result is either yes or no. If the t CALC is > than the t TABLE at the specified (95%) confidence level, then there is evidence of bias. Distinguish here between expected concentrations, based on the vitamin pill label or the Diet Coke manufacturer specification, measured concentrations, based on your calibration curve and the instrument signal, and standard or prepared concentrations based on mass and dilution of standards that you prepared. Note in this section if any of the calibration data were thrown out! Note whether the validation data were in agreement with the calibration or not. According to the validation standards, how accurate are the results? 55

7 LONG REPORT FORMAT AND GRADING RUBRIC 6.6. Make a calibration graph from your analyte absorbance values as illustrated below Preferably on a separate page All the points are shown, including: the regression line, validations, the sample absorbance is indicated with a horizontal line intersecting the calibration line the uncertainty of the sample absorbance (if known) is indicated by two parallel lines drawn at the sample absorbance plus and minus the standard deviation in the sample absorbance. Your experimental uncertainty may be too small to do this graphically, but it illustrates nicely the way that the uncertainty in the sample absorbance propagates into an uncertainty in the sample concentration. You may be able to address the question of whether this instrumental method is suitable in terms of detection limit for the given analysis 6.7. [Not required for Analysis Format] Discuss the least-squares (linear regression) analysis. Note that this implies that you are fitting the data to a model, e.g. A = m*c[ppm] + Sb. Report the best-fit sensitivity, m, and blank signal, Sb and their respective uncertainties. Put the actual regression and propagation of error calculations in the appendix [If validation and sample data are available] Discuss the tests for bias between validation and expectation, sample and expectation and samplesample. This is a simple conversation Do not forget to list the final results of the analysis here. This means the amount of the analyte that is in a meaningful amount (e.g. a serving) of the original sample, e.g. 4 grams of spinach or 12 ounces of diet coke. Compare this value to what is expected for this product Make it clear that you understand the results. Discuss the relative value of the validation versus random errors. Do sample-to-sample variations swamp the calculated standard deviations and if so, what does this mean? For the HPLC report, discuss the gradient separations as indicated on the printout References: List the references here that correspond to the numbered citations in the text. Just like you were taught in 100W. References must be archival sources, that is, no web URL s without my explicit permission. NIST may be the only exception I make. 56

8 LONG REPORT FORMAT AND GRADING RUBRIC 7. List of References: Cite the source(s) of information (total citations anticipated: 4-8 and may include your textbook. Use the ACS Analytical Chemistry format the analytical method (FAAS or HPLC) and 7.2. the importance of measuring, e.g. caffeine content and 7.3. articles or book information on how to measure, e.g. Fe using FAAS All references included should be cited in the paper One web URL, if I let you use it, must be archival in quality, reputable and cited according to ACS guidelines (see 100W format). 8. Tables and Figures: Put the titled and numbered tables and figures together, in order immediately following the references. Figures should have a numbered figure caption. Mainly, this is a place to summarize the results. Please only put here the figures and tables that you produce, not the ones that the instrument makes. Finally, every figure that you put here should be referred to in the text. All figures must be clearly labeled. Avoid dark backgrounds and unnecessary information. Neat hand work on figures is perfectly acceptable Primary Calibration Standards First Validation Standard Second Validation Standard Digested Spinach Sample Absorbance Mg Concentration [PPM] Figure 2. Calibration plot for FAAS absorbance of magnesium vs. standard concentration in ppm. Sample absorbance and standard deviaton is noted as a horizontal line with dashed lines at ±1 standard deviatons. Validation points (triangle and square) are plotted versus their prepared concentrations. Vertical displacement from the calibration line indicates systematic error. 57

9 LONG REPORT FORMAT AND GRADING RUBRIC 9. Appendix: Put your calculations here. Neat handwork is fine but I expect to see samples of all the important calculations that you performed. If you used a computer program (e.g. Microsoft Excel ) please print out a report from the program illustrating the results. I do not expect anyone to do the linear regression by hand! Some students like to use MathCad for this, and it is extremely efficient and transparent for this goal. 58

10 LONG REPORT FORMAT AND GRADING RUBRIC Diet coke injections: Reverse phase C18 column. Questions: 1. What elutes first, hydrophobic or hydrophilic components. 2. How many peaks can be fully resolved for each gradient? Why do they differ? 3. Which gradient resolves more components? 4. Which gradient elutes fastest? and why? Notes: Water phase is 0.1% H 3 PO 4 From bottom to top this water methanol gradient has increasing amounts of acetonitrile. HPLC 2 3/9/09 4:31:31 PM Roger Terrill Page 1 of 1 59

11 Math 9 Guide to Data Analysis: Long and Analysis Format Reports A major learning objective for this course is the successful and complete analysis of the data from a linear regression analysis. Our graduates consistently report that this skill, working with Excel in this way, was one of the most important things they learned in

12 THE OVERALL FLOW OF YOUR DATA ANALYSIS WILL BE THIS: 1. Plot calibration data in Excel or equivalent. 2. Get regression coefficients (slope and intercept of best fit calibration line). Use spreadsheet to calculate sums, products etc. 3. Calculate the concentrations of your samples and validations. 4. Calculate the standard deviation estimates of your sample and validation concentrations (details on that in the supplement Guidance for Using Excel for Regression Analysis in Report uses Skoog appendix a1c, equation a1-37) 5. Use the sample preparation procedure to calculate the amount (in mg) of analyte in your sample specimen (vitamin tablet or can of coke, details below). 6. Use the error propagation rules to calculate the standard deviations in mg of analyte in your sample specimen. See Skoog appendix a1b Use the t-test to evaluate the difference between the expected and measured values. See guidance below. The following two pages contain printouts of a calibration curve analysis of the HPLC data from a previous lab. The first page displays the numbers, with experimental data in the gray, shaded area. The second page displays the formulae used to calculate the results. Please use this as an example for the creation of a spreadsheet of your own that you will use to analyze the data in your homework sets (as applicable) as well as your two principle lab reports (HPLC and FAAS) analyses. While Excel will perform linear regression and give you the slope and intercept of the line that best fits your data, it will not give you the errors in the coefficients or sufficient data to do an error analysis of a predicted value that you may derive from using the (linear) calibration curve coefficients. The worksheet uses formulae identical to those found in Skoog Appendix A, and these have been shown to work with one exception! In the 5 th edition, there is a mistake in In Appendix 1, A- 19: The least squares slope of a line is incorrectly given as: m = S xx / S yy This should read: m = S xy / S xx 61

13 NOTES ON USING EXCEL: If you want a cell to contain a formula that is, the result of a calculation based on other cell s data then you must enter the formula starting with =. It you use the Excel toolbar button, for example, to enter a sum (Σ), then the = will be entered for you. If the result that you get is important, and will be used in other calculations, you can name that cell, and it s result. So, in doing this spreadsheet, I named the calculations the same way that Skoog did in appendix A, with names like S XX and S XY etc. That way, I can enter the name of the cell in later calculations, rather than the cell itself (e.g. C4). The advantage of this is twofold. First, the formulas are much clearer if they contain names as opposed to cell addresses like C4. Second, if the S XY cell moves (for example if you insert a row to add data), then C4 changes, but S XY does not! So your formula does not need to be changed if you reference a named cell. To name a cell, simply single-click on the cell (so that the focus is on the cell, not to be editing in the cell, the result of a double-click on the cell). Then click on Insert Name Define and give the cell a name (like Sxy or m or slope or answer or concentration or whatever you prefer). 62

14 Benzoic Acid x - PPM y - Abs x-squared x-xavg y-yavg x-xavgsqr y-yavgsqr xy x-xavg*y-yavg yfit Experimental E E E E E E E E Data E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E sums => E E E E E E E E+01 averages => E E+01 N = 11 M = 1 Y_abs_unk E-01 Number of Calibration Pts Repetitions of Unknown Measurement Signal for Analyte Sxx E+02 Syy E+00 Sxy E+01 sr E-02 Numbers used to calculate slope, intercept and standard deviations. Slope = E-01 Sigmam E-03 Intercept = E-02 Sigmab E-02 Answers C = 5.74 ± sc = 1.37 Concentration of the unknown Estimate of the uncertainty in the concentration of the unknown propagation of errors: sc = 1.09 Estimate of the uncertainty in the concentration by error propagation 63

15 Benzoic Acid x - PPM y - Abs x-squared x-xavg y-yavg x-xavgsqr y-yavgsqr xy x-xavg*y-yavg Experimental0 0 =C4*C4 =C4-xavg =D4-yavg =F4*F4 =G4*G4 =C4*D4 =F4*G4 Data =C5*C5 =C5-xavg =D5-yavg =F5*F5 =G5*G5 =C5*D5 =F5*G =C6*C6 =C6-xavg =D6-yavg =F6*F6 =G6*G6 =C6*D6 =F6*G =C7*C7 =C7-xavg =D7-yavg =F7*F7 =G7*G7 =C7*D7 =F7*G7 sums => =SUM(C4:C7) =SUM(D4:D7) =SUM(E4:E7) =SUM(F4:F7) =SUM(G4:G7) =SUM(H4:H7) =SUM(I4:I7) =SUM(J4:J7) =SUM(K4:K7) averages => =AVERAGE(C4:C7) =AVERAGE(D4:D7) =AVERAGE(E4:E7) N = 4 M = 1 Y_abs_unk Number of Calibr Repetitions of U Signal for Ana Sxx =Sxx Syy =Syy Sxy =Sxy sr =SQRT((Syy-(m*m*Sxx))/N-2) Numbers used to Slope = =Sxy/Sxx Sigmam =sy/sqrt(sxx) Intercept = =yavg-m*xavg Sigmab =sy/(sqrt(1/(n-(sumx*sumx/sumxsqr)))) Answers C = =(Y_abs_unk-b)/m ± sc = =sy/m*(sqrt((1/m)+(1/n)+(y_abs_unk-yavg)^2/(m*m*sxx))) Concentration of Estimate of 8.0E+06 Signal / Arbitrary Units 6.0E E E E Concentration / ppm s c s r m 1 M + 1 N + ( ) y c y m 2 Sxx This gives us the standard deviation estimate for results derived from a calibration curve. This can be turned into a CI using N-2 degrees of freedom. Sxx s r ( x x i avg ) 2 i i y i ( ) mx + b i 2 N 2 N is the number of calibration standards M is the number of times you averaged the sample to get the average signal y (often this is 1) y is the signal (e.g. absorbance) of the sample yc is the average of the signals of the calibration standards m is the slope Sxx is defined below sr (also sometimes called sy) is the standard error of the regression. 64

16 COMPARING YOUR ANSWER WITH WHAT YOU THINK THE ANSWER SHOULD BE. Use the following example to help you to compare your answer to the known answer. Case I is for comparing your value to some known or ideal value such as the label on the bottle of the vitamin tablet or the reported exact value for something. Case II is for comparing, for example, your two results for the mg of Fe. This could be a comparison between two tablets or cans of soda for example. For comparing: mg caffeine in a Diet Coke can to expectation (45 mg as of Spring 08) and validation measurements to their expected values For comparing: mg caffeine in a Diet Coke can 1 to mg caffeine in a Diet Coke can 2. and mg benzoic acid in a Diet Coke 1 to mg benzoic acid in a Diet Coke 2. Case 1. Comparing a Measured Result with a Known Value: t calc x avg x known s N x avg = average of N measurements x known = exact known or true value degrees of freedom = N - 1 If t_calc is greater than t_table, then you can conclude that there is a difference between the known and measured value - if you use the 95% confidence interval to find t_calc you will be wrong in your assertion that the true population mean is within this interval only once every twenty times. You cannot however conclude that the measured and true values are equal. =================================================================== Case 2. Comparing Two Measured Results: ( ) ( ) 2 2 x 1 x 2 N 1 N 2 s 1 N1 1 + s 2 N2 1 t calc s s pooled N 1 + N pooled 2 N 1 + N 2 2 x 1 and x 2 = the averages of N 1 and N 2 measurements degrees of freedom for two averages = N TOTAL - 2 = N 1 +N 2-2 degrees of freedom for two cal curve results = N TOTAL = N STD1 +N STD2-4 e.g. N TOTAL = for two, five-standard results like caffeine from cans 1 and 2 65

17 Table of Student s t-values. The value of t in the above is derived from the following table: Confidence Level: of Freedom 50% 90% 95% 98% 99% 99.50% 99.90%

18 Once you get your concentration of Fe for example, it needs to be converted into and amount per tablet (or per can in HPLC). This gives an example of how this is done, but you must use your procedure to work this out for your sample. For calculating the amount in mg/tablet of Fe: Assuming the measured concentration was: 15.3 ppm Tablet preparation was: dissolved acid and diluted to ml, then 20.0 ml of this was diluted to ml It is also perfectly valid to change the units on the 95% confidence interval before you propagate the error mg L 100 ml 0.250L = 19.1mg 20 ml per tablet (because all Fe comes from one tablet) For calculating the standard deviation estimate of this value: Standard deviation in concentration was: 0.83 ppm Using multiplication rule: x s x x ab c s a a 2 + s b b 2 + s c c 2 If this is a standard deviation, it can be converted into a 95% CI using the N-2 degrees of freedom from the calibration curve. And volumetric glassware tolerances (tables below): 0.83 ppm 15.3 ppm ml 100 ml ml 25 ml ml mg = 1.0 mg 250 ml tablet tablet Note that in this case none of the dilutions are expected to contribute any random error to the final result. 67

19 For dilutions, error is anticipated to accumulate (i.e. propagate) according to these approximate values: Vol flask tolerances: Flask Capacity / ml Tolerance / ±ml Pipet tolerances: Pipet Capacity / ml Tolerance / ±ml

20 Use the t-test to evaluate the difference between the expected and measured values using the Case 1 and Case 2 formulas on the following page. Note that you will be doing three t-tests: Does the validation standard concentration agree with expectation? (Case 1. Caffeine and benzoic acid) Does the average of the 2 samples agree with expectation? (Case 1., caffeine only) Does sample 1 agree with sample 2? (Case 2. Caffeine and benzoic acid) These tests may answer the questions Are the samples different from the label? and Are the two samples the same? Use the confidence tests as described in class and summarized below. Note that if you are comparing two measured values, then you use a modified form of the t-test shown below. Degrees of freedom for computing CI in final results: In computing t (or CI), for results from the cal curve: The degrees of freedom = N-2 where N is the the number of standards. 69

21 Once you have conducted t-tests for your two samples and your validation, consider the following truth table: Validation agreement w expectation at 95% confidence level. Sample 1 agreement w sample 2 at 95% confidence level. Average of samples agree w/ expectation at 95% confidence level. Evidence that sample is not as labeled? Evidence that the two samples differ from each other? Yes Yes Yes No No Yes Yes No Yes No Yes No Yes No Yes Yes No No Yes Yes No Yes Yes No No No Yes No No No No No Yes No Yes No No No No Yes Evaluate your experiments against the above matrix to test for systematic error and possible conclusions. 70

V. LAB REPORT. PART I. ICP-AES (section IVA)

V. LAB REPORT. PART I. ICP-AES (section IVA) V. LAB REPORT The lab report should include an abstract and responses to the following items. All materials should be submitted by each individual, not one copy for the group. The goal for this part of

More information

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Figure 1. Structures for Vitamin B2 and Vitamin B1. CH 461 & CH 461H F 18 Name Experiment 2C Integrated Laboratory Experiment DETERMINATION OF RIBOFLAVIN: A COMPARISON OF TECHNIQUES PART C. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY The purpose of this experiment

More information

you-try-it-04.xlsx Step-by-Step Guide ver. 9/4/2009

you-try-it-04.xlsx Step-by-Step Guide ver. 9/4/2009 you-try-it-04.xlsx Step-by-Step Guide ver. 9/4/2009 Abstract This document provides step-by-step instructions for the Excel workbook you-try-it-04.xlsx (Excel 2007). The worksheets contain data for practice

More information

Oddo-Harkins rule of element abundances

Oddo-Harkins rule of element abundances Page 1 of 5 Oddo-Harkins rule of element abundances To instructors This is a simple exercise that is meant to introduce students to the concept of isotope ratios, simple counting statistics, intrinsic

More information

Quantitative Analysis of Caffeine in Energy Drinks by High Performance Liquid Chromatography

Quantitative Analysis of Caffeine in Energy Drinks by High Performance Liquid Chromatography Quantitative Analysis of Caffeine in Energy Drinks by High Performance Liquid Chromatography CHEM 329 Professor Vogt TA: Fahad Hasan Allison Poget Date Performed: April 5, 2016 Date Submitted: April 12,

More information

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013 Absorbance Experiment 13 Dilutions and Data Handling in a Spreadsheet rev 1/2013 GOAL: This lab experiment will provide practice in making dilutions using pipets and introduce basic spreadsheet skills

More information

DETERMINATION OF AN EQUILIBRIUM CONSTANT

DETERMINATION OF AN EQUILIBRIUM CONSTANT DETERMINATION OF AN EQUILIBRIUM CONSTANT In this experiment the equilibrium properties of the reaction between the iron(iii) ion and the thiocyanate ion will be studied. The relevant chemical equation

More information

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Figure 1. Structures for Vitamin B2 and Vitamin B1. CH 461 & CH 461H F 15 Name Experiment 2C Integrated Laboratory Experiment DETERMINATION OF RIBOFLAVIN: A COMPARISON OF TECHNIQUES PART C. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY The purpose of this experiment

More information

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD APPENDIX V TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD Validating Chromatographic Methods. By David M. Bliesner Copyright 2006 John Wiley & Sons, Inc. 159 160 APPENDIX V Title: Effective: Document No:

More information

EXPERIMENT 30A1: MEASUREMENTS. Learning Outcomes. Introduction. Experimental Value - True Value. 100 True Value

EXPERIMENT 30A1: MEASUREMENTS. Learning Outcomes. Introduction. Experimental Value - True Value. 100 True Value 1 Learning Outcomes EXPERIMENT 30A1: MEASUREMENTS Upon completion of this lab, the student will be able to: 1) Use various common laboratory measurement tools such as graduated cylinders, volumetric flask,

More information

Since the publication of the ISO Guide to the Expression

Since the publication of the ISO Guide to the Expression DE SILVA: JOURNAL OF AOAC INTERNATIONAL VOL. 86, NO. 5, 003 1077 SPECIAL GUEST EDITOR SECTION Uncertainty of Analytical Determinations GALAPPATTI M.S. DE SILVA 4, PB Alwis Perera Mawatha, Katubedda, Sri

More information

-However, this definition can be expanded to include: biology (biometrics), environmental science (environmetrics), economics (econometrics).

-However, this definition can be expanded to include: biology (biometrics), environmental science (environmetrics), economics (econometrics). Chemometrics Application of mathematical, statistical, graphical or symbolic methods to maximize chemical information. -However, this definition can be expanded to include: biology (biometrics), environmental

More information

Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks

Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks bjective: The purpose of this experiment is to quantify the caffeine content of a diet soda sample using Ultra-High Performance

More information

Error Analysis, Statistics and Graphing Workshop

Error Analysis, Statistics and Graphing Workshop Error Analysis, Statistics and Graphing Workshop Percent error: The error of a measurement is defined as the difference between the experimental and the true value. This is often expressed as percent (%)

More information

CHEMISTRY DEPARTMENT

CHEMISTRY DEPARTMENT POINT LEPREAU GENERATING STATION GADOLINIUM ARSENAZO III Issued By: Date: APPROVED BY: of 6 REVISION RECORD AUTHOR REV DESCRIPTION DATE 0 Initial Issue W. Mawhinney Not Tracked Oct./9 W. T. Underhill 2

More information

Chem 155 Midterm Exam Page 1 of 10 Spring 2010 Terrill

Chem 155 Midterm Exam Page 1 of 10 Spring 2010 Terrill Chem 155 Midterm Exam Page 1 of 10 ame Signature 1. Mercury (Hg) is is believed to be hazardous to human neurological health at extremely low concentrations. Fortunately EPA Method 45.7 cold vapor atomic

More information

Two-Stage Course-Embedded Determination of Caffeine and Related Compounds by HPLC in Caffeine Containing Food, Beverages and (or) Related Products

Two-Stage Course-Embedded Determination of Caffeine and Related Compounds by HPLC in Caffeine Containing Food, Beverages and (or) Related Products Journal of Laboratory Chemical Education 2017, 5(2): 19-25 DOI: 10.5923/j.jlce.20170502.02 Two-Stage Course-Embedded Determination of Caffeine and Related Compounds by HPLC in Caffeine Containing Food,

More information

Introduction to Spectroscopy: Analysis of Copper Ore

Introduction to Spectroscopy: Analysis of Copper Ore Introduction to Spectroscopy: Analysis of Copper Ore Using a Buret and Volumetric Flask: 2.06 ml of solution delivered 2.47 ml of solution delivered 50.00 ml Volumetric Flask Reading a buret: Burets are

More information

Introduction to Uncertainty and Treatment of Data

Introduction to Uncertainty and Treatment of Data Introduction to Uncertainty and Treatment of Data Introduction The purpose of this experiment is to familiarize the student with some of the instruments used in making measurements in the physics laboratory,

More information

Experiment. Quantification of Ascorbic acid by Fluorescence Spectroscopy1

Experiment. Quantification of Ascorbic acid by Fluorescence Spectroscopy1 Experiment. Quantification of Ascorbic acid by Fluorescence Spectroscopy Modified 10/2017 Experiment. Quantification of Ascorbic acid by Fluorescence Spectroscopy1 Objective: The goal of this experiment

More information

Determining the Conductivity of Standard Solutions

Determining the Conductivity of Standard Solutions Determining the Conductivity of Standard Solutions by Anna Cole and Shannon Clement Louisiana Curriculum Framework Content Strand: Science as Inquiry, Physical Science Grade Level 11-12 Objectives: 1.

More information

INSTRUCTIONS FOR WRITING CIPAC METHODS

INSTRUCTIONS FOR WRITING CIPAC METHODS INSTRUCTIONS FOR WRITING CIPAC METHODS Introduction CIPAC methods are intended to be used by many people whose native language is not English. Writers of methods should keep this in mind and should use

More information

Chemistry 112 Laboratory Experiment 7: Determination of Reaction Stoichiometry and Chemical Equilibrium

Chemistry 112 Laboratory Experiment 7: Determination of Reaction Stoichiometry and Chemical Equilibrium Chemistry 112 Laboratory Experiment 7: Determination of Reaction Stoichiometry and Chemical Equilibrium Introduction The word equilibrium suggests balance or stability. The fact that a chemical reaction

More information

Statistical Analysis of Engineering Data The Bare Bones Edition. Precision, Bias, Accuracy, Measures of Precision, Propagation of Error

Statistical Analysis of Engineering Data The Bare Bones Edition. Precision, Bias, Accuracy, Measures of Precision, Propagation of Error Statistical Analysis of Engineering Data The Bare Bones Edition (I) Precision, Bias, Accuracy, Measures of Precision, Propagation of Error PRIOR TO DATA ACQUISITION ONE SHOULD CONSIDER: 1. The accuracy

More information

Uncertainty, Error, and Precision in Quantitative Measurements an Introduction 4.4 cm Experimental error

Uncertainty, Error, and Precision in Quantitative Measurements an Introduction 4.4 cm Experimental error Uncertainty, Error, and Precision in Quantitative Measurements an Introduction Much of the work in any chemistry laboratory involves the measurement of numerical quantities. A quantitative measurement

More information

MEASUREMENT: PART II

MEASUREMENT: PART II 1 MEASUREMENT: PART II Copyright: Department of Chemistry, University of Idaho, Moscow, ID 83844-2343, 2013. INTRODUCTION Read and/or review Section 1.7 and Figure 7.5 in your textbook. The first part

More information

A Spectrophotometric Analysis of Calcium in Cereal

A Spectrophotometric Analysis of Calcium in Cereal CHEM 311L Quantitative Analysis Laboratory Revision 1.2 A Spectrophotometric Analysis of Calcium in Cereal In this laboratory exercise, we will determine the amount of Calium in a serving of cereal. We

More information

Experiment 1 (Part A): Plotting the Absorption Spectrum of Iron (II) Complex with 1,10- Phenanthroline

Experiment 1 (Part A): Plotting the Absorption Spectrum of Iron (II) Complex with 1,10- Phenanthroline Experiment (Part A): Plotting the Absorption Spectrum of Iron (II) Complex with,0- Phenanthroline Background The first step of an analytical spectrophotometric procedure for quantitative determination

More information

ISP 207L Supplementary Information

ISP 207L Supplementary Information ISP 207L Supplementary Information Scientific Notation Numbers written in Scientific Notation are composed of two numbers. 1) Digit term A number between 1 and 10 2) Exponential term Integer power of 10

More information

Determination of Caffeine by HPLC

Determination of Caffeine by HPLC Determination of Caffeine by HPLC Introduction It was a long history before real high performance liquid chromatography (HPLC) had evolved. The very first indication of a chromatographic separation was

More information

After successfully completing this laboratory assignment, including the assigned reading, the lab

After successfully completing this laboratory assignment, including the assigned reading, the lab University of California at Santa Cruz Jack Baskin School of Engineering Electrical Engineering Department EE-145L: Properties of Materials Laboratory Lab 6: Temperature Dependence of Semiconductor Conductivity

More information

Introduction to Spectroscopy: Analysis of Copper Ore

Introduction to Spectroscopy: Analysis of Copper Ore Introduction to Spectroscopy: Analysis of Copper Ore Thousands of years ago, copper was abundant enough in quantity that it could be found on the Earth s surface. Prospecting for copper then was relatively

More information

Error Analysis General Chemistry Laboratory November 13, 2015

Error Analysis General Chemistry Laboratory November 13, 2015 Error Analysis General Chemistry Laboratory November 13, 2015 Error and uncertainty may seem synonymous with trivial mistakes in the lab, but they are well defined aspects of any numerical measurement

More information

Determination of the Equilibrium Constant for the Iron (III) thiocynate Reaction

Determination of the Equilibrium Constant for the Iron (III) thiocynate Reaction Lab 4. Determination of the Equilibrium Constant for the Iron (III) thiocynate Reaction Prelab Assignment Before coming to lab: After reading "Lab Notebook Policy and Format for Lab Reports" handout, complete

More information

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets Liquid chromatography was developed by Tswett in early 1900 s and was shown to be a powerful separation

More information

Microsoft Excel Directions

Microsoft Excel Directions Microsoft Excel Directions 1. Working in groups of two, log onto a computer. 2. Create a folder on the desktop a. Right click anywhere on the desktop new folder Name the folder Chemistry 3. Open MS Excel

More information

5-Sep-15 PHYS101-2 GRAPHING

5-Sep-15 PHYS101-2 GRAPHING GRAPHING Objectives 1- To plot and analyze a graph manually and using Microsoft Excel. 2- To find constants from a nonlinear relation. Exercise 1 - Using Excel to plot a graph Suppose you have measured

More information

Chem 155 Midterm Exam Page 1 of 10 Spring 2011 Terrill

Chem 155 Midterm Exam Page 1 of 10 Spring 2011 Terrill Chem 155 Midterm Exam Page 1 of 10 Spring 011 Terrill ame Signature Experimental design: 1. Selenium (Se) is toxic and teratogenic above about 100 μg / day. Yet vitamin tablets often list 100 μg of selenium

More information

How to Write a Laboratory Report

How to Write a Laboratory Report How to Write a Laboratory Report For each experiment you will submit a laboratory report. Laboratory reports are to be turned in at the beginning of the lab period, one week following the completion of

More information

Basic Statistics. 1. Gross error analyst makes a gross mistake (misread balance or entered wrong value into calculation).

Basic Statistics. 1. Gross error analyst makes a gross mistake (misread balance or entered wrong value into calculation). Basic Statistics There are three types of error: 1. Gross error analyst makes a gross mistake (misread balance or entered wrong value into calculation). 2. Systematic error - always too high or too low

More information

Spectrophotometric Determination of Ferrocyanide in Effluents

Spectrophotometric Determination of Ferrocyanide in Effluents Spectrophotometric Determination of Ferrocyanide in Effluents ECN-0025-1 INTRODUCTION This method is used to determine the concentration of ferrocyanide ion in photoprocessing solution effluents. The ion

More information

The SuperBall Lab. Objective. Instructions

The SuperBall Lab. Objective. Instructions 1 The SuperBall Lab Objective This goal of this tutorial lab is to introduce data analysis techniques by examining energy loss in super ball collisions. Instructions This laboratory does not have to be

More information

Determination of an Equilibrium Constant

Determination of an Equilibrium Constant Last updated 1/29/2014 - GES Learning Objectives Students will be able to: Determine the numerical value of an equilibrium constant from measured concentrations of all reaction species. Use an absorption

More information

Determination of Density 1

Determination of Density 1 Introduction Determination of Density 1 Authors: B. D. Lamp, D. L. McCurdy, V. M. Pultz and J. M. McCormick* Last Update: February 1, 2013 Not so long ago a statistical data analysis of any data set larger

More information

Introduction to Spectroscopy: Analysis of Copper Ore

Introduction to Spectroscopy: Analysis of Copper Ore Introduction to Spectroscopy: Analysis of Copper Ore Using a Buret and Volumetric Flask: 2.06 ml of solution 2.47 ml of solution 50.00 ml delivered delivered Volumetric Flask Reading a buret: Burets are

More information

Metolachlor ESA Sodium Salt Standard

Metolachlor ESA Sodium Salt Standard Analytical Reference Materials Metolachlor ESA Sodium Salt Standard Catalog # 33200 Lot # A0102104 110 Benner Circle Bellefonte, PA 16823-8812 1-814-353-1300 1-800-356-1168 www.restek.com FOR LABORATORY

More information

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy A. Evaluation of Analytical Parameters in Atomic Absorption Spectroscopy Objective The single feature that contributes most to making atomic

More information

Brooklyn College Department of Chemistry

Brooklyn College Department of Chemistry Brooklyn College Department of Chemistry Instrumental Analysis (Chem 42/790) Atomic Absorption Spectroscopy An atomic absorption spectrometer is used in this experiment to analyze a copper-base alloy for

More information

Experiment 1 - Mass, Volume and Graphing

Experiment 1 - Mass, Volume and Graphing Experiment 1 - Mass, Volume and Graphing In chemistry, as in many other sciences, a major part of the laboratory experience involves taking measurements and then calculating quantities from the results

More information

ANALYTICAL METHOD PROCEDURES

ANALYTICAL METHOD PROCEDURES HPLC ASSAY AND RELATED SUBSTANCE Column Eurospher 100, C18, 25 x 0.40 cm 5µ Mobile Phase Buffer ph 2.0*: Acetonitrile (88:12 v/v) * Buffer ph 2 Potassium dihydrogen phosphate (KH 2 PO 4 ) - 0.68g Hepatane

More information

1 Measurement Uncertainties

1 Measurement Uncertainties 1 Measurement Uncertainties (Adapted stolen, really from work by Amin Jaziri) 1.1 Introduction No measurement can be perfectly certain. No measuring device is infinitely sensitive or infinitely precise.

More information

Chapter 4: Verification of compendial methods

Chapter 4: Verification of compendial methods Chapter 4: Verification of compendial methods Introduction In order to ensure accurate and reliable test results, the quality control laboratory (QCL) needs to use analytical methods (and accompanying

More information

Statistics: Error (Chpt. 5)

Statistics: Error (Chpt. 5) Statistics: Error (Chpt. 5) Always some amount of error in every analysis (How much can you tolerate?) We examine error in our measurements to know reliably that a given amount of analyte is in the sample

More information

STAT 350 Final (new Material) Review Problems Key Spring 2016

STAT 350 Final (new Material) Review Problems Key Spring 2016 1. The editor of a statistics textbook would like to plan for the next edition. A key variable is the number of pages that will be in the final version. Text files are prepared by the authors using LaTeX,

More information

Absorption Spectra of Cyanine Dyes

Absorption Spectra of Cyanine Dyes Reading/Preparation Absorption Spectra of Cyanine Dyes The basic theory and the description of the experimental procedure are given in your lab text 1 as experiment 34. Look carefully at the method and

More information

ANALYSIS OF ZINC IN HAIR USING FLAME ATOMIC ABSORPTION SPECTROSCOPY

ANALYSIS OF ZINC IN HAIR USING FLAME ATOMIC ABSORPTION SPECTROSCOPY ANALYSIS OF ZINC IN HAIR USING FLAME ATOMIC ABSORPTION SPECTROSCOPY Introduction The purpose of this experiment is to determine the concentration of zinc in a sample of hair. You will use both the calibration

More information

11.1 Uncertainty and error in measurement (1 Hour) 11.2 Uncertainties in calculated results (0.5 Hour) 11.3 Graphical techniques (0.

11.1 Uncertainty and error in measurement (1 Hour) 11.2 Uncertainties in calculated results (0.5 Hour) 11.3 Graphical techniques (0. Chapter 11 Measurement and Data Processing Page 1 Students are to read and complete any part that requires answers and will submit this assignment on the first day of class. You may use internet sources

More information

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY CHAPTER 9 DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY CHAPTER 9 Determination of drug release during

More information

Chem 310, Fall 2005 Final Exam December 15, :15-12:15 (You must stop working at 12:15!)

Chem 310, Fall 2005 Final Exam December 15, :15-12:15 (You must stop working at 12:15!) NAME: Chem 310, Fall 2005 Final Exam December 15, 2005 10:15-12:15 (You must stop working at 12:15!) There are 3 pages of questions on this exam (not counting this page), with points allocated as indicated.

More information

Laboratory Measurements and Procedures

Laboratory Measurements and Procedures 18 Introduction Measurements of masses, volumes, and preparation of chemical solutions of known composition are essential laboratory skills. The goal of this exercise is to gain familiarity with these

More information

Determination of the Equivalent Weight and Ionization Constant of a Weak Acid

Determination of the Equivalent Weight and Ionization Constant of a Weak Acid Determination of the Equivalent Weight and Ionization Constant of a Weak Acid Introduction: The object of this experiment will be to determine the ionization constant, K a, and the equivalent weight of

More information

2 One-dimensional motion with constant acceleration

2 One-dimensional motion with constant acceleration 2 One-dimensional motion with constant acceleration Experiment objectives: 1. Achieve a better understanding of how to solve position, velocity and acceleration problems in one-dimensional motion with

More information

MORE LIGHTS, COLOR, ABSORPTION!

MORE LIGHTS, COLOR, ABSORPTION! Name Partner(s) Section Date MORE LIGHTS, COLOR, ABSORPTION! PRE-LAB QUERIES 1. The terms absorption and transmittance are often used when describing the interaction of light with matter. Explain what

More information

Chemistry Gas Chromatography: Separation of Volatile Organics

Chemistry Gas Chromatography: Separation of Volatile Organics Chemistry 3200 Gas chromatography (GC) is an instrumental method for separating volatile compounds in a mixture. A small sample of the mixture is injected onto one end of a column housed in an oven. The

More information

WISE Regression/Correlation Interactive Lab. Introduction to the WISE Correlation/Regression Applet

WISE Regression/Correlation Interactive Lab. Introduction to the WISE Correlation/Regression Applet WISE Regression/Correlation Interactive Lab Introduction to the WISE Correlation/Regression Applet This tutorial focuses on the logic of regression analysis with special attention given to variance components.

More information

Experiment 1 Chemical Kinetics 1

Experiment 1 Chemical Kinetics 1 Experiment 1 Chemical Kinetics 1 Purpose: Determine the rate law for the reaction of the dye crystal violet with hydroxide. Reading: Brown, et. al., Chemistry The Central Science, sections 14.1 14.4. Introduction

More information

PHYSICS LAB FREE FALL. Date: GRADE: PHYSICS DEPARTMENT JAMES MADISON UNIVERSITY

PHYSICS LAB FREE FALL. Date: GRADE: PHYSICS DEPARTMENT JAMES MADISON UNIVERSITY PHYSICS LAB FREE FALL Printed Names: Signatures: Date: Lab Section: Instructor: GRADE: PHYSICS DEPARTMENT JAMES MADISON UNIVERSITY Revision August 2003 Free Fall FREE FALL Part A Error Analysis of Reaction

More information

Uncertainty and Graphical Analysis

Uncertainty and Graphical Analysis Uncertainty and Graphical Analysis Introduction Two measures of the quality of an experimental result are its accuracy and its precision. An accurate result is consistent with some ideal, true value, perhaps

More information

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (11) 04 QUALIFICATION OF EQUIPMENT ANNEX 1: QUALIFICATION OF HPLC EQUIPMENT Full document title and reference Document type

More information

Name Lab Exercise 2 - Standard Curves Nitrate, Ammonia, Phosphorus, and Chlorophyll

Name Lab Exercise 2 - Standard Curves Nitrate, Ammonia, Phosphorus, and Chlorophyll Name Lab Exercise 2 - Standard Curves Nitrate, Ammonia, Phosphorus, and Chlorophyll For most analytical chemical procedures, we use "standard curves" to calibrate our measurements. For example, we want

More information

Experiment 7A ANALYSIS OF BRASS

Experiment 7A ANALYSIS OF BRASS Experiment 7A ANALYSIS OF BRASS FV 10/21/10 MATERIALS: Spectronic 20 spectrophotometers, 2 cuvettes, brass sample, 7 M HNO 3, 0.100 M CuSO 4, 2 M NH 3, two 50 ml beakers, 100 ml beaker, two 25 ml volumetric

More information

Passing-Bablok Regression for Method Comparison

Passing-Bablok Regression for Method Comparison Chapter 313 Passing-Bablok Regression for Method Comparison Introduction Passing-Bablok regression for method comparison is a robust, nonparametric method for fitting a straight line to two-dimensional

More information

Appendix II- Bioanalytical Method Development and Validation

Appendix II- Bioanalytical Method Development and Validation A2. Bioanalytical method development 1. Optimization of chromatographic conditions Method development and optimization of chromatographic parameters is of utmost important for validating a method in biological

More information

CH 2212 Lab Exploration Standard Addition in Spectrophotometry

CH 2212 Lab Exploration Standard Addition in Spectrophotometry CH 2212 Lab Exploration Standard Addition in Spectrophotometry Now that you have successfully generated a linear calibration plot for MnO 4 - in the Calibration Curves in Spectrophotometry exploration,

More information

Using Microsoft Excel

Using Microsoft Excel Using Microsoft Excel Objective: Students will gain familiarity with using Excel to record data, display data properly, use built-in formulae to do calculations, and plot and fit data with linear functions.

More information

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION Rate Law Determination of Crystal Violet Hydroxylation Revised 5/22/12 RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION Adapted from "Chemistry with Computers" Vernier Software, Portland OR, 1997

More information

Instructor s Advance Preparation

Instructor s Advance Preparation INSTRUCTOR'S MANUAL Instructor s Advance Preparation This protocol is designed for 80 workstations of 4 students. Each group will prepare a set of standards, a blank, and 2 milk samples (can be a blind

More information

Lab 6. RC Circuits. Switch R 5 V. ower upply. Voltmete. Capacitor. Goals. Introduction

Lab 6. RC Circuits. Switch R 5 V. ower upply. Voltmete. Capacitor. Goals. Introduction Switch ower upply Lab 6. RC Circuits + + R 5 V Goals Capacitor V To appreciate the capacitor as a charge storage device. To measure the voltage across a capacitor as it discharges through a resistor, and

More information

High Performance Liquid Chromatography (HPLC) of Three Analgesics

High Performance Liquid Chromatography (HPLC) of Three Analgesics High Performance Liquid Chromatography (HPLC) of Three Analgesics OVERVIEW/THEORY Real-life samples are often complex mixtures of many substances (e.g., sea water contains many salts and other impurities

More information

CHEM 334 Quantitative Analysis Laboratory

CHEM 334 Quantitative Analysis Laboratory The Methods of Calibration Curve and Standard Addition Introduction One of the principle activities in the Quantitative Analysis Laboratory is the measurement of the concentration or total quantity of

More information

DETERMINATION OF K c FOR AN EQUILIBRIUM SYSTEM

DETERMINATION OF K c FOR AN EQUILIBRIUM SYSTEM DETERMINATION OF K c FOR AN EQUILIBRIUM SYSTEM 1 Purpose: To determine the equilibrium constant K c for an equilibrium system using spectrophotometry to measure the concentration of a colored complex ion.

More information

Beer's Law and Data Analysis *

Beer's Law and Data Analysis * OpenStax-CNX module: m15131 1 Beer's Law and Data Analysis * Mary McHale This work is produced by OpenStax-CNX and licensed under the Creative Commons Attribution License 2.0 1 Beer's Law and Data Analysis

More information

Switch + R. ower upply. Voltmete. Capacitor. Goals. Introduction

Switch + R. ower upply. Voltmete. Capacitor. Goals. Introduction Lab 6. Switch RC Circuits ower upply Goals To appreciate the capacitor as a charge storage device. To measure the voltage across a capacitor as it discharges through a resistor, and to compare + the result

More information

The Theory of HPLC. Quantitative and Qualitative HPLC

The Theory of HPLC. Quantitative and Qualitative HPLC The Theory of HPLC Quantitative and Qualitative HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference

More information

PHYSICS 2150 LABORATORY LECTURE 1

PHYSICS 2150 LABORATORY LECTURE 1 PHYSICS 2150 LABORATORY LECTURE 1 1865 Maxwell equations HISTORY theory expt in 2150 expt not in 2150 SCOPE OF THIS COURSE Experimental introduction to modern physics! Modern in this case means roughly

More information

CCME Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons (PHC) in Soil - Tier 1 Method

CCME Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons (PHC) in Soil - Tier 1 Method Rating Guide Appendix for the CCME Reference Method for the Canada-Wide Standard for Petroleum (PHC) in Soil - Tier 1 Method (Note: Checklist incorporates requirements from Dec 2000 version + Addendum

More information

Lecture 3. - all digits that are certain plus one which contains some uncertainty are said to be significant figures

Lecture 3. - all digits that are certain plus one which contains some uncertainty are said to be significant figures Lecture 3 SIGNIFICANT FIGURES e.g. - all digits that are certain plus one which contains some uncertainty are said to be significant figures 10.07 ml 0.1007 L 4 significant figures 0.10070 L 5 significant

More information

AP Chemistry Laboratory #15: Reaction Rate of Crystal Violet and Sodium Hydroxide. Lab days: Thursday and Friday, February 1-2, 2018

AP Chemistry Laboratory #15: Reaction Rate of Crystal Violet and Sodium Hydroxide. Lab days: Thursday and Friday, February 1-2, 2018 AP Chemistry Laboratory #15: Reaction Rate of Crystal Violet and Sodium Hydroxide Lab days: Thursday and Friday, February 1-2, 2018 Lab due: TBD Goal (list in your lab book): The goal of this lab is to

More information

Lab 11 Simple Harmonic Motion A study of the kind of motion that results from the force applied to an object by a spring

Lab 11 Simple Harmonic Motion A study of the kind of motion that results from the force applied to an object by a spring Lab 11 Simple Harmonic Motion A study of the kind of motion that results from the force applied to an object by a spring Print Your Name Print Your Partners' Names Instructions April 20, 2016 Before lab,

More information

Chemistry 213. A KINETIC STUDY: REACTION OF CRYSTAL VIOLET WITH NaOH LEARNING OBJECTIVES

Chemistry 213. A KINETIC STUDY: REACTION OF CRYSTAL VIOLET WITH NaOH LEARNING OBJECTIVES Chemistry 213 A KINETIC STUDY: REACTION OF CRYSTAL VIOLET WITH NaOH The objectives of this experiment are to... LEARNING OBJECTIVES study the reaction rate of crystal violet with NaOH using a Spectronic

More information

PRELIMINARY ACTIVITY FOR

PRELIMINARY ACTIVITY FOR PRELIMINARY ACTIVITY FOR Beer s Law Investigations Guided Inquiry Version Experiment 11 The primary objective of this Preliminary Activity is to determine the concentration of an unknown copper (II) sulfate

More information

SPECIMEN L2. Level 1/2 Cambridge National Certificate in R075/02 SCIENCE IN THE WORKPLACE. Duration: 1 hour. Candidate Forename.

SPECIMEN L2. Level 1/2 Cambridge National Certificate in R075/02 SCIENCE IN THE WORKPLACE. Duration: 1 hour. Candidate Forename. SPECIMEN L2 Level 1/2 Cambridge National Certificate in R075/02 SCIENCE IN THE WORKPLACE R075: How scientific data is used (Level 2) Candidates answer on the question paper OCR Supplied Materials: None

More information

What is measurement uncertainty?

What is measurement uncertainty? What is measurement uncertainty? What is measurement uncertainty? Introduction Whenever a measurement is made, the result obtained is only an estimate of the true value of the property being measured.

More information

CHAPTER - 3 ANALYTICAL PROFILE. 3.1 Estimation of Drug in Pharmaceutical Formulation Estimation of Drugs

CHAPTER - 3 ANALYTICAL PROFILE. 3.1 Estimation of Drug in Pharmaceutical Formulation Estimation of Drugs CHAPTER - 3 ANALYTICAL PROFILE 3.1 Estimation of Drug in Pharmaceutical Formulation 3.1.1 Estimation of Drugs ANALYTICAL PROFILE 84 3.1 ESTIMATION OF DRUG IN PHARMACEUTICAL FORMULATION. Agrawal A et al

More information

ADVANCED ANALYTICAL LAB TECH (Lecture) CHM

ADVANCED ANALYTICAL LAB TECH (Lecture) CHM ADVANCED ANALYTICAL LAB TECH (Lecture) CHM 4130-0001 Spring 2013 Professor Andres D. Campiglia Textbook: Principles of Instrumental Analysis Skoog, Holler and Crouch, 5 th Edition, 6 th Edition or newest

More information

Introduction to Computer Tools and Uncertainties

Introduction to Computer Tools and Uncertainties Experiment 1 Introduction to Computer Tools and Uncertainties 1.1 Objectives To become familiar with the computer programs and utilities that will be used throughout the semester. To become familiar with

More information

The following are excerpted from the lab manual with a couple of extra figures for your guidance.

The following are excerpted from the lab manual with a couple of extra figures for your guidance. Short Lab Report Guide: The following are excerpted from the lab manual with a couple of extra figures for your guidance. ABC-UV-VIS Calculations: As indicated above in the theory section, calculate the

More information

experiment3 Introduction to Data Analysis

experiment3 Introduction to Data Analysis 63 experiment3 Introduction to Data Analysis LECTURE AND LAB SKILLS EMPHASIZED Determining what information is needed to answer given questions. Developing a procedure which allows you to acquire the needed

More information

And how to do them. Denise L Seman City of Youngstown

And how to do them. Denise L Seman City of Youngstown And how to do them Denise L Seman City of Youngstown Quality Control (QC) is defined as the process of detecting analytical errors to ensure both reliability and accuracy of the data generated QC can be

More information

Preparation of Standard Curves. Principle

Preparation of Standard Curves. Principle Preparation of Standard urves Principle Many laboratory tests require the measurement of concentration be evaluated or read in a photometer (colorimeter or spectrophotometer). Since these instruments are

More information