MATRIX-INDEPENDENT XRF METHODS FOR CERTIFICATION OF STANDARD REFERENCE MATERIALS

Size: px
Start display at page:

Download "MATRIX-INDEPENDENT XRF METHODS FOR CERTIFICATION OF STANDARD REFERENCE MATERIALS"

Transcription

1 Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume MATRIX-INDEPENDENT XRF METHODS FOR CERTIFICATION OF STANDARD REFERENCE MATERIALS ABSTRACT John R. Sieber National Institute of Standards and Technology 100 Bureau Dr., Mail Stop 8391, Gaithersburg, MD , USA The Spectrochemical Methods Group of the Analytical Chemistry Division at the National Institute of Standards and Technology develops and applies matrix-independent methods for its certification of Standard Reference Materials (SRM). Such methods are required to achieve accuracy, i.e., to minimize potential sources of analytical uncertainty. This paper delineates a matrix-independent method for X-ray fluorescence spectrometry that uses destructive sample preparation instead of matrix corrections. The method is based on borate fusion of samples and synthesis of calibration standards that closely mimic the complete composition of the fused samples. The method is described in detail and illustrated using recent work on cements and zeolites. A typical uncertainty budget is itemized and sources of uncertainty are discussed. Expanded relative uncertainties are 1 % or lower. The technique is applicable to major, minor and sometimes trace constituents. Excellent agreement is demonstrated with both a classical gravimetric method and instrumental neutron activation analysis. INTRODUCTION The NIST Analytical Chemistry Division (ACD) has as its primary mission the improvement of chemical metrology in support of the United States economy [1,2,3]. This mission is accomplished, in part, by the development of new analytical methods for application to industrial, environmental and healthcare problems and by the development of Standard Reference Materials (SRM) with which users can establish traceability to NIST calibration and measurement certificates. The broad scope of the Division s mission results in analyses of a wide variety of materials. Accuracy, the principle goal of NIST measurement and standards efforts, is achieved when all sources of analytical uncertainty are understood and minimized. For this reason, the ACD emphasizes the application of matrix-independent methods in its work [4]. Although matrix-dependent methods are important and broadly applied in chemical analysis, the reliance of these methods on standards similar in matrix composition to the unknowns limits their utility to certifying new standards with similar matrix composition. In fact, matrixdependent methods create much of the demand for the breadth and quality of reference materials, especially for calibration of instrumentation. In X-ray fluorescence spectrometry (XRF), a matrix-independent method may involve fundamental parameters calculations, matrix correction algorithms, or a number of calibration techniques. This paper explores one useful approach for the development of reference materials. It describes a matrix-independent XRF method through which the calibration of the spectrometer is directly related to primary reference materials and through which a variety of materials of different matrix are directly related to said calibration without the use of mathematical correction procedures or matrix-matched reference materials (hereafter called artifact standards). This

2 This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website ICDD Website -

3 Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume approach sets aside matrix corrections in favor of destructive and somewhat labor-intensive sample preparation. Recent work on cements and zeolites using the method of borate fusion demonstrates the usefulness of this procedure for matrix independence in XRF. Sources of random error are minimized by taking advantage of the excellent repeatability of the borate fusion technique, analytical balances, and X-ray spectrometers. Sources of bias are minimized by the preparation of bracketing calibration standards from ultrahigh purity compounds and NIST Single Element Standard Solutions SRMs. A typical error budget is itemized and explained. Expanded relative uncertainties are 1 % or lower. Excellent agreement is obtained with classical methods and other instrumental techniques. MATRIX-INDEPENDENCE The primary goal of matrix-independence is to address the effects of differences in matrix among materials and to eliminate those differences as a source of bias. As stated in the introduction, there are a number of possible approaches to matrix-independence for XRF. It is well known that matrix differences lead to X-ray spectral responses that differ due to the absorption of characteristic X-rays, the amount of scattering of primary X-rays, and spectral line overlaps. Even among materials of a similar matrix composition, there may be differences due to surface finish or particle size distribution resulting from grinding and polishing. In the worst case, there may be no reference materials similar to the unknown and the analyst will have no choice but to use destructive sample preparation. In addition to the elimination of sources of bias is the objective to reduce the specificity of the procedure so it can be applied simultaneously to a variety of materials and to as many constituents of those materials as possible. The internal standard technique illustrates this point since it can be used to eliminate matrix differences as a source of bias. However, the application is limited to a narrow range of materials into which the internal standard is completely miscible and that do not contain a significant quantity of any element having an absorption edge between the internal standard element and the analyte. Consequently, the use of internal standards is limited to specific materials and constituents, i.e., it is not matrix-independent. Because XRF is nondestructive and artifact standards are widely available for many materials, the majority of XRF analysts choose to collect a set of artifact standards similar to their unknowns to create calibrations. Analyses are fast because little or no labor is required once calibrations are established. One reason people request new SRMs from NIST is that new materials require new artifact standards for new calibrations. A second reason they come to NIST is to obtain artifact standards for verification of method accuracy as part of their quality system. The artifact standards can be used to create calibration curves, with or without corrections for interelement effects and matrix absorption. The process can be combined with fundamental parameters software that calculates the corrections from first principles with the advantage that it requires fewer artifact standards. NIST procedures for value assignment of reference materials allow the use of this approach to calibrate XRF. It is acceptable for a NIST analyst to calibrate a spectrometer using artifact

4 Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume standards. However, the process must be fully documented with an exhaustive error analysis and the uncertainty must be quite small to make the result useful for value assignment. To ensure that an SRM is useful for decision-making in product quality control, the stated uncertainty of the certified value should be an order of magnitude smaller than the product specification range for the manufacturing process. Therefore, the NIST method of analysis must be inherently better than any quality control requirement. NIST strives to obtain levels of uncertainty that are more stringent, often better by a factor of 10, than related, industrial quality control applications. A way to reduce biases when using artifact standards is to get standards that are closer in composition to the unknown and have stated uncertainties that are similar in magnitude to the total uncertainty needed for the new SRM. This puts the analyst in a conundrum because he needs high quality artifact standards of nearly the same composition as the requested SRM in order to create a new SRM. Destructive sample preparation provides another approach. If the analyst can relate the calibration of the spectrometer directly to primary reference materials, the reliance on artifact standards is eliminated. Primary reference materials, pure elements and pure compounds are carefully characterized so that the stated uncertainty in an assigned value is significantly smaller than for most artifact standards. Pure compounds are available with assay values exceeding % purity. G. Staats published the results of a careful study of the certainty of such an assay [5] and sources of uncertainty introduced by handling pure compounds and concluded that it was possible to limit the uncertainty to the order of 0.03 % to 0.1 %. For certified reference materials and other artifact standards, estimates of uncertainty in composition values are nearly always one order of magnitude greater. To take advantage of this superior quality, the analyst must prepare samples without introducing significant sources of bias. They must synthesize calibration standards that closely match the prepared samples. The match must be close enough to control matrix effects, which usually means that all elements must be accounted for and the mass fractions in the synthetic standards must be within a few percent relative of the unknown. The ideal case for SRM value assignment would use a matrix-independent method that provides a comparison of the unknown material to one or more primary reference materials. One mode for value-assignment and certification is measurement using a single, primary method of analysis [4]. While this mode of value-assignment does not state that primary reference materials must be used, it does list a number of requirements for a primary method: 1. a. A primary direct method measures the value of an unknown without reference to a standard; or b. A primary ratio method measures the value of a ratio of an unknown to a standard of the same quantity; its operation must be completely described by a measurement equation. 2. Certification at NIST requires that all potentially significant sources of error have been evaluated explicitly for the application of the method and the matrix under investigation. 3. Confirmation of measurements must be accomplished by determination of certified constituents in certified reference materials of similar matrix, or by a second NIST technique, or by results from selected outside laboratories. In the face of these requirements, an X-ray spectroscopist must decide how to achieve matrixindependence. For most industrial materials, there are two obvious paths to be explored: 1) destructive sample preparation with synthetic calibration standards and 2) fundamental parameters calculations with a set of reference materials with similar matrix composition to the

5 Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume unknown. It will be shown below that option 1 using the technique of borate fusion has fewer sources of uncertainty than option 2. BRACKETING STANDARDS The borate fusion process represents a solution to most of the difficulties of other forms of destructive sample preparation. Borate fusion has been discussed extensively in numerous articles and books in the scientific literature [6-14]. Many methods have been documented and the list of difficulties is relatively short. If a material can be oxidized and fused, it can be converted to a homogeneous solid solution. It is well known that oxidized materials dissolve in the flux at temperatures well below the melting point of the compound minimizing losses of volatile elements. Borate fusion has been used in the past to create synthetic calibration standards from primary reference materials. However, these synthetic standards covered wide ranges of mass fraction and were used in combination with matrix correction algorithms. Calibration standards can be prepared to bracket unknowns that have been fused in the same manner. To obtain control over inter-element effects, the bracketing standards are designed to mimic the entire unknown specimen in its fused form for all analytes. That is, the mass fractions of all major and minor constituents of the synthetic standards and fused specimens differ by no more than a few percent relative. A small level of variety is designed into the synthetic standards so they can be used to create straight-line calibrations without the use of influence coefficients. Correlations of high and low mass fractions are avoided. All of the preparation work is done gravimetrically using an analytical balance. The author developed a set of procedures that take advantage of the combination of XRF and borate fusion to create an analysis method that provides complete control over sources of uncertainty. The process relies on careful attention to good weighing practices. All mass values are corrected for buoyancy. Dilution factors are calculated from the mass of the sample and the total mass of borate glass created by fusion. The Pt crucible and casting dish are weighed before and after fusion to account for all borate glass. No corrections are required for loss on ignition. The process consists of the following steps. 1. Perform a preliminary analysis of the unknown using a fundamental parameters-based method to identify all analytes and their approximate mass fractions in the material. 2. Create a procedure for borate fusion of the unknown using a low dilution factor and a low temperature to prevent loss by volatilization. Characterize the repeatability of the procedure. 3. For the unknowns, prepare duplicate fused specimens from each of at least six containers. At NIST, the number and identities of containers is chosen by a qualified statistician. 4. Analyze the unknown in its fused form using the fundamental parameters-based method. The results of this analysis are the target values for design of synthetic calibration standards. 5. To decide which elements to include in the synthetic standards, combine the list of analytes with any additional elements that exhibit significant matrix effects on the analytes. 6. Design at least four synthetic calibration standards, made from primary reference materials, which bracket all constituents of the fused unknown to within ±2.5 % relative for major constituents, ±5 % for minor constituents, and within the linear calibration range for trace constituents, usually up to approximately 300 mg/kg in fused form.

6 Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume Prepare small quantities of the primary reference compounds according to established heat treatment practices to ensure that the compounds have the correct stoichiometry and moisture content [15-17]. 8. Dilute individual reference compounds or metals by borate fusion when the mass to be weighed for the synthetic standards is less than 50 mg because the uncertainty due to weighing becomes significant below 50 mg on a 5-place analytical balance. 9. Create an XRF measurement program for all analytes, plus the tube Compton scatter peak and a line from the halide used in the non-wetting agent. Acquire count rate data for all measured lines and backgrounds with counting statistical errors below 0.1 % preferably, below 0.25 % if possible, or with the lowest uncertainty possible. 10. Prepare one synthetic standard and measure it alongside one fused unknown specimen to verify that the range of count rates of the synthetic standards will bracket the unknowns. If not, redesign the remaining synthetic standards before preparing them. 11. Choose a control sample, preferably a certified reference material of similar matrix to the unknown, and prepare it in duplicate by borate fusion. Fuse a quantity of the control sample that results in a borate bead containing as many analytes in the bracketed calibration range as possible. For example, if the unknowns were prepared using 0.5 g and the control contains lower levels of major and minor constituents, it may be appropriate to fuse 0.75 g to get the fused control beads to more closely match the unknown sample beads. 12. Measure all synthetic calibration standards and unknown specimens in random order. 13. Create calibrations using a straight-line model for all analytes incorporating line overlap corrections, if needed, and using the tube Compton scatter measurement to correct for bead mass thickness effects, if needed and where possible. 14. Calculate compositions for all analytes in all unknown specimens and perform an analysis of uncertainty according to NIST policy [18]. 15. Use the results for the control sample(s) to test for biases in the analytical results [19]. This may require more than just duplicate specimens of the control. This approach requires the laboratory to maintain a collection of ultrahigh purity compounds, metals, and primary solution standards. In the author s laboratory, oxide and carbonate compounds and metals are used as ingredients for synthetic standards. Metals and NIST single element solution standards are employed to verify the assay of each batch of commercial, ultrahigh purity compound. EXPERIMENTAL All specimens were prepared using the method of borate fusion. A Philips/SOLED Perl X 3 automated bead preparation machine was used to fuse and cast samples as 30 mm diameter beads. For portland cements and their associated synthetic standards, fusion was carried out at a temperature of 975 ºC for 6 minutes to fuse 2.50 g of cement with 5.00 g of flux (pre-fused 66 % lithium tetraborate, 34 % lithium metaborate by mass, % purity). For zeolite materials and their associated synthetic standards, fusion was carried out at a temperature of 1100 ºC for 6 minutes to fuse either 0.75 g of material with 6.25 g of flux or 0.50 g with 6.50 g of flux. Lithium iodide solution (0.25 g/g) was used as a non-wetting agent. Beads were cast in one of two platinum dishes, which were shown to produce identical beads having flat, smooth surfaces requiring no surface preparation before measurement.

7 Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume Portland cement was sampled and analyzed as received, which is the conventional approach in the cement industry [20]. The three Zeolite materials, Linde Type A (LTA), faujasite (FAU), and ZSM-5 (MFI) were sampled on a hydrated basis. Specimens were placed in small, plastic weighing scoops, hydrated for at least 48 h and weighed in a glove box maintained at 54 % RH ± 1 % RH [21] using a slurry of Mg(NO 3 ) 2. The maximum depth of material in each scoop was 5 mm. Therefore, the scoops held only 0.75 g of LTA, 0.75 g of FAU or 0.50 g of MFI. A Philips model PW2404 WDXRF spectrometer was used to measure the K-L 2,3 characteristic X-rays of all elements. Measurements were performed in vacuum with the generator operated at 3.6 kilowatts. A single sample holder with a 29 mm inner diameter was used with a centering ring of Delrin plastic to carry samples into the spectrometer and hold them in the measurement position. The mask between the sample and the collimator was set to view a 27 mm circular area of the sample. The L 3 -M 4,5 line of iodine was measured to correct the overlap of the I L 2 -M 4 line on the Ti K-L 2,3 line. The Rh KL Compton scatter line from the X-ray tube was measured as an internal reference to compensate for the effects of differences in bead mass thickness on elements with higher energy, characteristic X-rays. RESULTS AND DISCUSSION In a number of recent projects involving portland cement, the bracket standard approach was used to calibrate the spectrometer for 14 elements. Table 1 displays the compositions of four synthetic standards used for certification analysis of SRM 1880a. It is possible to demonstrate the improvement afforded by calibration using these bracketing standards by looking at the data for Fe 2 O 3. Figure 1 shows two calibration curves with curve 1a prepared using the original portland cement SRM series 1880, 1881, and curve 1b prepared using the four synthetic standards. Curve 1a uses certified mass fractions for all concentrations with alpha coefficients estimated from first principles to correct matrix absorption effects as in Equation 1. Curve 1b is a simple straight line with the net Fe count rate divided by the gross Rh KL Compton scatter count rate to correct for variations in bead mass thickness as in Equation 2. The plots include confidence intervals created using the Working-Hotelling-Schiff algorithm [22]. From the confidence intervals, one can estimate the uncertainty associated with prediction of a value of 1.00 % for the mass fraction of Fe 2 O 3 in a specimen. For curve 1a, the estimated uncertainty is % mass fraction, which is clearly unacceptable for value assignment of a certified reference material. For curve 1b, the effort required to prepare synthetic standards is rewarded with an uncertainty of % mass fraction. C j C = + + i D ( L i i, l Cl ) Ei R 1 i α i, j l j 100 C i Di l ( i, l l E = L C ) + i Ri Rs (1) (2) where C = mass fraction (%), D = y-axis intercept, L = line overlap correction factor, E = the inverse of the sensitivity, R = net count rate, α ij = matrix influence coefficient.

8 Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume There are several reasons for the improvement in performance gained from bracketing standards. First, chemical composition values for the SRMs have associated uncertainty values that are significantly greater than the uncertainties in the assay values for the high purity compounds used to prepare the synthetic standards. Second, in curve 1a, there are no points in the immediate vicinity of 1 % mass fraction, causing the calculated confidence intervals to broaden. Third, Equation 1 describing the calibration with matrix corrections is subject to a larger number of sources of uncertainty than a simple straight-line model. It is obvious that a number of parameters in Equation 1 are not needed in Equation 2. Each of these parameters (α ij and C j ) has an associated uncertainty that propagates into the final result. Therefore, synthetic bracketing standards provide a clear advantage by eliminating sources of uncertainty a Net Count Rate , Fe2O3 (%mass) b Figure 1. a. Calibration Using 1880-series Portland Cement SRMs b. Calibration Using Synthetic Standards from Table 1. Ratio (Fe/Rh) , Fe2O3, %mass It is useful to illustrate the reduction in matrix corrections obtained with bracketing standards compared to calibration using artifact standards. In Table 2, α Fej C j /100 values (column 4) are the matrix corrections needed for the effect of each compound on the measured amount of Fe 2 O 3 when artifact standards are used along with Eq 1. The total correction, calculated from the term in Eq 1. containing α ij, is greater than 120 % of the amount of Fe 2 O 3. Column 5 of Table 2 shows the matrix effect,, which remains when using bracketing standards. The value of was

9 Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume calculated from the product of the α ij and one-half the range of the mass fraction of each compound in the synthetic standards in Table 1. In this example, the matrix effects are reduced to less than This value could be reduced further with closer bracketing of the CaO mass fraction. However, the design of the synthetic standards ensures that the analyte is subject to a slightly greater absorption due to a given interfering element in some standards while it is subject to a slightly lesser absorption in the other standards. Therefore, the variety designed into the synthetic standards contributes to the error of the fit of a straight-line model to the measured count rates and chemical composition values. So long as the unknowns are completely bracketed by the synthetic standards, no additional corrections or components of uncertainty are needed because the uncertainty is adequately estimated by the rms error in the straight line fit. Table 1. Compositions of Synthetic Bracket Standards for SRM 1880a Portland Cement. All values in mass fraction (%) ID 80a1 80a2 80a3 80a4 Compound CaO SiO Al 2 O Fe 2 O SO MgO K 2 O TiO Na 2 O SrO P 2 O Mn 2 O ZnO Cr 2 O An example of the power of the borate fusion/synthetic standard approach is found in recent analyses of zeolite compounds. XRF, instrumental neutron activation analysis (INAA) and a gravimetric method using Na 2 CO 3 fusions were used to analyze three zeolite compounds for the elements Si, Al, Na, and Fe. The details of the gravimetric and INAA methods are beyond the scope of this paper; however, the author can provide information on request. Comparisons of the results are shown in Table 3 for Si, Table 4 for Al, Table 5 for Na, and Table 6 for Fe. Several things are clear from the information in these tables. For Si, the XRF approach rivals gravimetry for accuracy and expanded uncertainty. For Al, Na, and Fe, the XRF approach is superior to INAA for expanded uncertainty. This is due to the fact that in this particular determination INAA suffers from low count rates that limit the inherent precision of the method. Examination of the data for Al and Na in FAU and LTA zeolites reveals that the XRF and INAA results do not agree within the 95 % confidence intervals. The results agree when the expanded uncertainty estimates are expressed at the 99 % confidence level. This is an indication that an unidentified

10 Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume source of uncertainty or bias exists in one or both methods. Therefore, additional investigation is required before a certified value can be assigned. This problem would not have been discovered if the XRF work was done using artifact standards for calibration. Table 2. Matrix Effects in Fused Specimens of Portland Cement. Compound Average α Fej α Fej C j /100 mass fraction (%) CaO SiO Al 2 O Fe 2 O SO MgO K 2 O TiO Na 2 O SrO P 2 O Mn 2 O ZnO Cr 2 O Total Correction = where: Average = average composition of four synthetic standards in Table 1, α Fej = theoretical coefficients calculated using average composition, and = matrix effect due to range of composition of bracketing standards. The uncertainty budget for XRF analysis of FAU zeolite (faujasite) in Table 7 is instructive for the magnitudes of the various components of uncertainty. A Type A uncertainty component is estimated using statistical methods. A Type B uncertainty component is estimated using other means such as manufacturer s specifications, prior experience, and uncertainties assigned to reference data [18]. Even with the advantages of bracketing standards, the most significant source of uncertainty is the fit of the calibration model, Eq. 2, to the measured count rates and calculated mass fractions for the synthetic standards. In this case, five synthetic standards were created which explains why there are three degrees of freedom in the calibration fit. CONCLUSION The combination of borate fusion, synthetic bracketing standards and X-ray fluorescence spectrometry constitutes a matrix-independent analysis method. Synthetic bracketing standards, while labor-intensive, offer significant reduction of the uncertainty due to calibration by eliminating matrix differences among samples and calibration standards. The calibration approach is simplified considerably and no artifact standards are needed. Borate fusion allows flexibility in the choice of control samples for validation of the method because the dilution

11 Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume factor can be adjusted so that fused beads prepared from the control sample match beads prepared from unknowns. One disadvantage of borate fusion is dilution of the matrix and reduced capability for determination of trace constituents. Of course, this depends on the nature of the specimens and the dilution required to create stable, homogeneous borate beads. In the zeolite example, XRF rivals a classical method for accuracy and expanded uncertainty. Performance also compares favorably to instrumental neutron activation analysis. When applied for certification analyses for SRM development, this approach results in expanded uncertainty estimates (95 % confidence level) in the range of 0.2 % to 1 % relative to the quantitative results. Table 3. Silicon in Zeolites XRF/Borate Fusion vs. Gravimetry Table 4. Aluminum in Zeolites XRF/Borate Fusion vs. INAA SRM Mass Fraction U Zeolite SRM Mass Fraction U Zeolite (proposed) (%) (%) (proposed) (%) (%) 2850 XRF Faujasite 2850 XRF Faujasite Grav INAA XRF Linde A 2851 XRF Linde A Grav INAA XRF ZSM XRF ZSM-5 Grav INAA Table 5. Sodium in Zeolites XRF/Borate Fusion vs. INAA Table 6. Iron in Zeolites XRF/Borate Fusion vs. INAA SRM Mass Fraction U Zeolite SRM Mass Fraction U Zeolite (proposed) (%) (%) (proposed) (%) (%) 2850 XRF Faujasite 2850 XRF Faujasite INAA INAA XRF Linde A 2851 XRF Linde A INAA INAA XRF <0.004 ZSM XRF ZSM-5 INAA INAA where: U = expanded uncertainty at the 95 % confidence level; Grav. = Gravimetry by Na 2 CO 3 fusion; INAA = Instrumental Neutron Activation Analysis These materials are under investigation and values may change prior to certification. ACKNOWLEDGEMENTS The author wishes to acknowledge the assistance of A. F. Marlow, who prepared most of the samples, and S. D. Leigh, who assisted with statistical evaluations. T. W. Vetter performed gravimetric determinations of Si in zeolites at NIST. R. Zeisler performed instrumental neutron activation analysis at NIST.

12 Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume Table 7. Uncertainty Budget for Faujasite Zeolite (FAU) from XRF Determinations. All values are % mass fraction with the relative uncertainty in parentheses below each value. Element Na Al Si Fe Recommended value Source of Uncertainty Type df Replication A (% relative) (0.26) (0.27) (0.30) (3.5) Calibration line fit A * (% relative) (0.07) (0.51) (0.67) (4.4) Calibration of balance B inf. (% relative) (0.01) (0.01) (0.01) (0.01) Weighing sample B inf. (% relative) (0.03) (0.03) (0.03) (0.03) Weighing glass B inf. (% relative) (0.01) (0.01) (0.01) (0.01) Compound assay B inf. (% relative) (0.10) (0.10) (0.10) (0.10) Combined, u c (% relative) (0.13) (0.32) (0.41) (1.9) Expanded, U = 2u c (% relative) (0.26) (0.64) (0.81) (3.8) Terms: df denotes degrees of freedom; * for Fe, df = 7; inf. signifies infinite; u c denotes combined uncertainty; U denotes expanded uncertainty estimated at the 95 % confidence level. DISCLAIMER Certain commercial products are identified in this paper to adequately specify the experimental procedure. Such identification does not imply recommendation or endorsement by the National Institute of Standards and Technology, nor does it imply that the products are necessarily the best available for the stated purpose. REFERENCES 1. National Institute of Standards and Technology, Public Internet Site, March 6, 2001.

13 Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume National Institute of Standards and Technology, Chemical Science and Technology Laboratory, Public Internet Site, March 6, National Institute of Standards and Technology, Chemical Science and Technology Laboratory, Analytical Chemistry Division, Public Internet Site, March 6, May, W., Parris, R., Beck, C., Fassett, J. Greenberg, R., Guenther, F., Kramer, G., Wise, S., Gills, T., Colbert, J., Gettings, R., and MacDonald, B., Definitions of Terms and Modes Used at NIST for Value-Assignment of Reference Materials for Chemical Measurements, NIST Spec. Pub , U. S. Government Printing Office, Washington, DC, 2000, 16pp. 5. Staats, G., Fresenius J. Anal. Chem. 336, 132 (1990). 6. Claisse, F., Norelco Reporter, Vol. III, No. 1, 3 (1957). 7. LeHouillier, R., Turmel, S., Claisse, F., Anal. Chem. 46, 734 (1974). 8. LeHouillier, R., Turmel, S., Claisse, F., Advances in X-Ray Analysis, Vol. 20, 459 (1977). 9. Haukka, M. T., Thomas, I. L., X-Ray Spectrom. 6(4), 204 (1977). 10. Couture, R. A., Advances in X-Ray Analysis, Vol. 32, 233 (1988). 11. Eastell, J., Willis, J. P., X-Ray Spectrom. 19(1), 3 (1990). 12. Alvarez, M., X-Ray Spectrom. 19(4), 203 (1990). 13. Eastell, J., Willis, J. P., X-Ray Spectrom. 22(2), 71 (1993). 14. Giles, H. L., Hurley, P. W., Webster, H. W. M., X-Ray Spectrom. 22(3), 132 (1995). 15. Staats, G., Fresenius Z. Anal. Chem. 330, 469 (1988). 16. Staats, G, and S. Strieder, X-Ray Spectrom. 22(3), 132 (1993). 17. Giles, H. L., Hurley, P. W., Ingham, M. N., X-Ray Spectrom. 24(3), 115 (1995). 18. Taylor, B. N. and C. E. Kuyatt, Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, NIST Tech. Note 1297, U. S. Printing Office, Washington, DC, 1994, 24 pp., Becker, D., R. Christensen, L. Currie, B. Diamondstone, K. Eberhardt, T. Gills, H. Hertz, G. Klouda, J. Moody, R. Parris, R. Schaffer, E. Steel, J. Taylor, R. Watters, and R. Zeisler, Use of NIST Standard Reference Materials for Decisions on Performance of Analytical Chemical Methods and Laboratories, NIST Spec. Pub. 829, U. S. Government Printing Office, Washington DC, 1992, 30 pp. 20. ASTM C , Standard Test Methods for Chemical Analysis of Hydraulic Cement, Annual Book of ASTM Standards, Vol , West Conshohocken, PA. 21. ASTM E (1996), Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Solutions, Annual Book of ASTM Standards, Vol , West Conshohocken, PA. 22. J. D. Spurrier, Encyclopedia of Statistical Sciences, Vol. 9, S. Kotz and C. B. Read, eds., pp , Wiley, New York, 1988.

EFFECT OF CALIBRATION SPECIMEN PREPARATION TECHNIQUES ON NARROW RANGE X-RAY FLUORESCENCE CALIBRATION ACCURACY

EFFECT OF CALIBRATION SPECIMEN PREPARATION TECHNIQUES ON NARROW RANGE X-RAY FLUORESCENCE CALIBRATION ACCURACY Copyright(c)JCPDS-International Centre for Diffraction Data 2000,Advances in X-ray Analysis,Vol.43 424 EFFECT OF CALIBRATION SPECIMEN PREPARATION TECHNIQUES ON NARROW RANGE X-RAY FLUORESCENCE CALIBRATION

More information

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K. 783 SCOPE AND LIMITATIONS XRF ANALYSIS FOR SEMI-QUANTITATIVE Introduction Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K. Historically x-ray fluorescence spectrometry has

More information

APPLICATION OF MICRO X-RAY FLUORESCENCE SPECTROMETRY FOR LOCALIZED AREA ANALYSIS OF BIOLOGICAL AND ENVIRONMENTAL MATERIALS

APPLICATION OF MICRO X-RAY FLUORESCENCE SPECTROMETRY FOR LOCALIZED AREA ANALYSIS OF BIOLOGICAL AND ENVIRONMENTAL MATERIALS Copyright(c)JCPDS-International Centre for Diffraction Data 2000,Advances in X-ray Analysis,Vol.43 540 APPLICATION OF MICRO X-RAY FLUORESCENCE SPECTROMETRY FOR LOCALIZED AREA ANALYSIS OF BIOLOGICAL AND

More information

FUNDAMENTAL PARAMETERS ANALYSIS OF ROHS ELEMENTS IN PLASTICS

FUNDAMENTAL PARAMETERS ANALYSIS OF ROHS ELEMENTS IN PLASTICS 45 ABSTRACT FUNDAMENTAL PARAMETERS ANALYSIS OF ROHS ELEMENTS IN PLASTICS W. T. Elam, Robert B. Shen, Bruce Scruggs, and Joseph A. Nicolosi EDAX, Inc. Mahwah, NJ 70430 European Community Directive 2002/95/EC

More information

Certificate of Analysis

Certificate of Analysis National Institute of Standards & Technology Certificate of Analysis Standard Reference Material 1648a Urban Particulate Matter This Standard Reference Material (SRM) is atmospheric particulate matter

More information

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA 90 RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA Christopher G. Worley Los Alamos National Laboratory, MS G740, Los Alamos, NM 87545 ABSTRACT Energy dispersive X-ray fluorescence (EDXRF) is a rapid, straightforward

More information

FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS

FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS 255 Yoshiyuki Kataoka 1, Naoki Kawahara 1, Shinya Hara 1, Yasujiro Yamada 1, Takashi Matsuo 1, Michael Mantler 2 1 Rigaku

More information

IMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE

IMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 158 IMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE B. H.

More information

Certificate. Standard Reference Material Near-Infrared Wavelength/Wavenumber Reflection Standard. ), 1.30 % samarium oxide (Sm 2

Certificate. Standard Reference Material Near-Infrared Wavelength/Wavenumber Reflection Standard. ), 1.30 % samarium oxide (Sm 2 National Institute of Standards & Technology Certificate Standard Reference Material 2036 Near-Infrared Wavelength/Wavenumber Reflection Standard This Standard Reference Material (SRM) is a certified transfer

More information

POWDER DIFFRACTION ANALYSIS OF HYDRAULIC CEMENTS: ASTM RIETVELD ROUND ROBIN RESULTS ON PRECISION

POWDER DIFFRACTION ANALYSIS OF HYDRAULIC CEMENTS: ASTM RIETVELD ROUND ROBIN RESULTS ON PRECISION Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 33 POWDER DIFFRACTION ANALYSIS OF HYDRAULIC CEMENTS: ASTM RIETVELD ROUND ROBIN RESULTS ON PRECISION

More information

AEROSOL FILTER ANALYSIS USING POLARIZED OPTICS EDXRF WITH THIN FILM FP METHOD

AEROSOL FILTER ANALYSIS USING POLARIZED OPTICS EDXRF WITH THIN FILM FP METHOD Copyright JCPDS-International Centre for Diffraction Data 2014 ISSN 1097-0002 219 AEROSOL FILTER ANALYSIS USING POLARIZED OPTICS EDXRF WITH THIN FILM FP METHOD Takao Moriyama 1), Atsushi Morikawa 1), Makoto

More information

ED(P)XRF: SCREENING ANALYSIS AND QUANTITATIVE ANALYSIS with POLARIZED

ED(P)XRF: SCREENING ANALYSIS AND QUANTITATIVE ANALYSIS with POLARIZED 384 ED(P)XRF: SCREENING ANALYSIS AND QUANTITATIVE ANALYSIS with POLARIZED X-RAYS R. Schramm, J. Heckel, K. Molt 2 Spectra Analytical Instruments, Kleve, Germany. 2Gerhard-Mercator- University Duisburg,

More information

ACCURATE QUANTIFICATION OF RADIOACTIVE MATERIALS BY X-RAY FLUORESCENCE: GALLIUM IN PLUTONIUM METAL

ACCURATE QUANTIFICATION OF RADIOACTIVE MATERIALS BY X-RAY FLUORESCENCE: GALLIUM IN PLUTONIUM METAL Copyright JCPDS - International Centre for Diffraction Data 2003, Advances in X-ray Analysis, Volume 46. 369 ACCURATE QUANTIFICATION OF RADIOACTIVE MATERIALS BY X-RAY FLUORESCENCE: GALLIUM IN PLUTONIUM

More information

XUV 773: X-Ray Fluorescence Analysis of Gemstones

XUV 773: X-Ray Fluorescence Analysis of Gemstones Fischer Application report vr118 HELM UT FISCHER GMBH + CO. KG Institut für Elektronik und Messtechnik Industriestrasse 21-7169 Sindelfingen, Germany Tel.: (+49) 731 33- - Fax: (+49) 731 33-79 E-Mail:

More information

THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS DIFFRACTION DATA

THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS DIFFRACTION DATA Copyright(c)JCPDS-International Centre for Diffraction Data 2001,Advances in X-ray Analysis,Vol.44 96 THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS

More information

MEASUREMENT CAPABILITIES OF X-RAY FLUORESCENCE FOR BPSG FILMS

MEASUREMENT CAPABILITIES OF X-RAY FLUORESCENCE FOR BPSG FILMS , MEASUREMENT CAPABILITIES OF X-RAY FLUORESCENCE FOR BPSG FILMS K.O. Goyal, J.W. Westphal Semiconductor Equipment Group Watkins-Johnson Company Scotts Valley, California 95066 Abstract Deposition of borophosphosilicate

More information

ANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION

ANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION 173 ANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION N. A. Raftery, L. K. Bekessy, and J. Bowpitt Faculty of Science, Queensland University of Technology, GPO Box 2434,

More information

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 236 ABSTRACT TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER Hagen Stosnach Röntec GmbH,

More information

VAM Project Development and Harmonisation of Measurement Uncertainty Principles

VAM Project Development and Harmonisation of Measurement Uncertainty Principles VAM Project 3.2.1 Development and Harmonisation of Measurement Uncertainty Principles Part (d): Protocol for uncertainty evaluation from validation data V J Barwick and S L R Ellison January 2000 LGC/VAM/1998/088

More information

Certificate of Analysis Standard Reference Material 2692c

Certificate of Analysis Standard Reference Material 2692c National Institute of Standards and Technology Certificate of Analysis Standard Reference Material 2692c Bituminous Coal (Sulfur, Mercury, and Chlorine) This Standard Reference Material (SRM) is intended

More information

Test Method: CPSC-CH-E

Test Method: CPSC-CH-E UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 10901 DARNESTOWN RD GAITHERSBURG, MD 20878 Test Method: CPSC-CH-E1001-08 Standard Operating Procedure

More information

BENEFITS OF IMPROVED RESOLUTION FOR EDXRF

BENEFITS OF IMPROVED RESOLUTION FOR EDXRF 135 Abstract BENEFITS OF IMPROVED RESOLUTION FOR EDXRF R. Redus 1, T. Pantazis 1, J. Pantazis 1, A. Huber 1, B. Cross 2 1 Amptek, Inc., 14 DeAngelo Dr, Bedford MA 01730, 781-275-2242, www.amptek.com 2

More information

Preparation of High Purity Plutonium Oxide for Radiochemistry Instrument Calibration Standards and Working Standards

Preparation of High Purity Plutonium Oxide for Radiochemistry Instrument Calibration Standards and Working Standards . LAUR 97-1 Preparation of High Purity Plutonium Oxide for Radiochemistry Instrument Calibration Standards and Working Standards Amy S. Wong and Nelson D. Stalnaker CST-8, MS G740 Los Alamos National Laboratory

More information

A61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012

A61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012 Revision 1.2 October 15, 2012 PAGE II TABLE OF CONTENTS TABLE OF CONTENTS... 1 GUIDANCE...2 1.0 Introduction... 2 2.0 Uncertainty and Traceability... 2 3.0 Need for Traceability... 3 3.1 What does traceability

More information

D y n a m a r. Polymer Processing Additives. Analysis of Dynamar Polymer Processing Additives in Polyolefins Using X-ray Fluorescence Spectrometry

D y n a m a r. Polymer Processing Additives. Analysis of Dynamar Polymer Processing Additives in Polyolefins Using X-ray Fluorescence Spectrometry D y n a m a r Polymer Processing Additives Analysis of Dynamar Polymer Processing Additives in Polyolefins Using X-ray Fluorescence Spectrometry Introduction Preparation of Calibration Standards and Samples

More information

ELECTRIC FIELD INFLUENCE ON EMISSION OF CHARACTERISTIC X-RAY FROM Al 2 O 3 TARGETS BOMBARDED BY SLOW Xe + IONS

ELECTRIC FIELD INFLUENCE ON EMISSION OF CHARACTERISTIC X-RAY FROM Al 2 O 3 TARGETS BOMBARDED BY SLOW Xe + IONS 390 ELECTRIC FIELD INFLUENCE ON EMISSION OF CHARACTERISTIC X-RAY FROM Al 2 O 3 TARGETS BOMBARDED BY SLOW Xe + IONS J. C. Rao 1, 2 *, M. Song 2, K. Mitsuishi 2, M. Takeguchi 2, K. Furuya 2 1 Department

More information

NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT

NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 266 NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT

More information

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

PARTICLE SIZE ANALYSIS OF GOLD NANOPARTICLES

PARTICLE SIZE ANALYSIS OF GOLD NANOPARTICLES PARTICLE SIZE ANALYSIS OF GOLD NANOPARTICLES Scientific interest in well dispersed suspensions of colloidal gold (or nanoparticles) can be traced back to ancient times. Original uses of colloidal gold

More information

Chem 321 Lecture 4 - Experimental Errors and Statistics 9/5/13

Chem 321 Lecture 4 - Experimental Errors and Statistics 9/5/13 Chem 321 Lecture 4 - Experimental Errors and Statistics 9/5/13 Student Learning Objectives Experimental Errors and Statistics The tolerances noted for volumetric glassware represent the accuracy associated

More information

Traceable UV-Vis Reference Materials

Traceable UV-Vis Reference Materials UV-Vis Spectroscopy Traceable UV-Vis Reference Materials For Regulatory Compliance Introduction Many laboratories, particularly in the pharmaceutical industry, are under increasing pressure to show proof

More information

DATA MINING WITH DIFFERENT TYPES OF X-RAY DATA

DATA MINING WITH DIFFERENT TYPES OF X-RAY DATA DATA MINING WITH DIFFERENT TYPES OF X-RAY DATA 315 C. K. Lowe-Ma, A. E. Chen, D. Scholl Physical & Environmental Sciences, Research and Advanced Engineering Ford Motor Company, Dearborn, Michigan, USA

More information

REFERENCE MATERIALS

REFERENCE MATERIALS REFERENCE MATERIALS 2018.1 www.spl-labmat.cz The SPL RM divide into four groups: CRM (with the status of national CRM) RM and QCM for quality control Hi Tec candidate materials to be ultimately certified

More information

ALLOWAY METHOD OUTLINE

ALLOWAY METHOD OUTLINE ALLOWAY METHOD OUTLINE Standard Laboratory Method SM4500-Cl -G Parameter Residual Chlorine & Free Chlorine Method DPD Colorimetric Test Kit Date Issued Originator: Section Supervisor: QA Manager Date:

More information

Morehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web: sales:

Morehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web:  sales: Morehouse 1 Morehouse Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA 17403 PH: 717-843-0081 web: www.mhforce.com sales: edlane@mhforce.com 2 This presentation will cover the calibration

More information

Overview of X-Ray Fluorescence Analysis

Overview of X-Ray Fluorescence Analysis Overview of X-Ray Fluorescence Analysis AMPTEK, INC., Bedford, MA 01730 Ph: +1 781 275 2242 Fax: +1 781 275 3470 sales@amptek.com 1 What is X-Ray Fluorescence (XRF)? A physical process: Emission of characteristic

More information

POWER UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES

POWER UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES Proceedings of the ASME 2014 Power Conference POWER2014 July 28-31, 2014, Baltimore, Maryland, USA POWER2014-32205 UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES Michael S. Hering Rosemount DP

More information

CALCULATION OF UNCERTAINTY IN CHEMICAL ANALYSIS. A.Gnanavelu

CALCULATION OF UNCERTAINTY IN CHEMICAL ANALYSIS. A.Gnanavelu CALCULATION OF UNCERTAINTY IN CHEMICAL ANALYSIS A.Gnanavelu UNCERTAINTY (U) Every measurement has error which is unknown and unknowable. This unknown error is called measurement uncertainty. Types of Error

More information

Technical Note A Quantification and NIST Traceability of Micromatter Thin Film Standards for XRF Analysis. Version March 16, 2017

Technical Note A Quantification and NIST Traceability of Micromatter Thin Film Standards for XRF Analysis. Version March 16, 2017 MICROMATTER TECHNOLOGIES INC. #1-8333 130 th Street, Surrey, B.C. V3W 7X4, Canada Phone: +1.604.594.9720 or 1.866.966.2286 Fax: +1.604.594.9726 info@micromatter.com www.micromatter.com Technical Note 2015-01A

More information

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium, 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

The bias component in measurement uncertainty

The bias component in measurement uncertainty Eurachem Workshop - Validation, May 01 The bias component in measurement uncertainty EURACHEM Workshop on Validation/Traceability/Measurement Uncertainty Challenges for the 1st Century s analysis Bertil

More information

EVALUATION OF VACUUM DRYING FOR DETERMINATION OF BULK SPECIFIC GRAVITY OF HMA SAMPLES

EVALUATION OF VACUUM DRYING FOR DETERMINATION OF BULK SPECIFIC GRAVITY OF HMA SAMPLES Cross and Pokhrel 1 EVALUATION OF VACUUM DRYING FOR DETERMINATION OF BULK SPECIFIC GRAVITY OF HMA SAMPLES 6784 Equivalent Words by: Stephen A. Cross, Ph.D., P.E. Professor School of Civil and Environmental

More information

NUCLE A R FORENSIC S INTERN ATION A L TECHNIC A L WORK ING GROUP ITWG GUIDELINE ON ELEMENTAL ASSAY U TITRATION

NUCLE A R FORENSIC S INTERN ATION A L TECHNIC A L WORK ING GROUP ITWG GUIDELINE ON ELEMENTAL ASSAY U TITRATION NUCLE A R FORENSIC S INTERN ATION A L TECHNIC A L WORK ING GROUP ITWG GUIDELINE ON ELEMENTAL ASSAY U TITRATION EXECUTIVE SUMMARY In this guide, the assay of uranium through titration refers to a methodology

More information

Certificate of Analysis

Certificate of Analysis Brammer Standard Company, Inc. Certificate of Analysis B.S. 60D Reference Material for AISI Grade 4340 Alloy Steel Certified Estimate of Certified Estimate of Value Uncertainty Value Uncertainty Analysis

More information

S8 TIGER Series 2 for ASTM D 6443

S8 TIGER Series 2 for ASTM D 6443 Lab Report XRF 139 S8 TIGER Series 2 for ASTM D 6443 Standard Test Method for Determination of Ca, Cl, Cu, Mg, P, S and Zn in Unused Lubricating Oils and Additives Introduction Lubricating oils are generally

More information

ICP-OES Application Note Number 35

ICP-OES Application Note Number 35 ICP-OES Application Note Number 35 Rapid measurement of major, minor and trace levels in soils using the Varian 730-ES Vincent Calderon Varian, Inc. Introduction As part of the global strategy for sustainable

More information

Neutron activation analysis. Contents. Introduction

Neutron activation analysis. Contents. Introduction Neutron activation analysis Contents Neutron activation analysis... 1 Introduction... 1 Principle of method... 2 Detection of radionuclides... 3 Kinetics of activation... 4 Choosing the appropriate procedure...

More information

CHARACTERIZING PROCESS SEMICONDUCTOR THIN FILMS WITH A CONFOCAL MICRO X-RAY FLUORESCENCE MICROSCOPE

CHARACTERIZING PROCESS SEMICONDUCTOR THIN FILMS WITH A CONFOCAL MICRO X-RAY FLUORESCENCE MICROSCOPE CHARACTERIZING PROCESS SEMICONDUCTOR THIN FILMS WITH A CONFOCAL MICRO X-RAY FLUORESCENCE MICROSCOPE 218 Chris M. Sparks 1, Elizabeth P. Hastings 2, George J. Havrilla 2, and Michael Beckstead 2 1. ATDF,

More information

Elemental analysis by X-ray f luorescence. Sequential benchtop WDXRF spectrometer

Elemental analysis by X-ray f luorescence. Sequential benchtop WDXRF spectrometer Elemental analysis by X-ray f luorescence Sequential benchtop WDXRF spectrometer Elemental analysis is one of the most important fundamental measurements made for industrial quality control and research

More information

Test Method Development and Validation as Pertaining to Microtrac Particle Size Measuring Instruments

Test Method Development and Validation as Pertaining to Microtrac Particle Size Measuring Instruments Test Method Development and Validation as Pertaining to Microtrac Particle Size Measuring Instruments Philip E. Plantz, PhD Application Note SL AN 17 Rev B Provided By: Microtrac, Inc. Particle Size Measuring

More information

QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY.

QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY. 1 REVISOR 4740.2100 4740.2100 QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY. Subpart 1. Scope. This part applies to laboratories performing testing under the inorganic chemistry, metals,

More information

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C Book 5 - Laboratory Policies and Procedures C03-1 2009-06-15 1 Scope 1.1 This method describes a general procedure for the determination of leachable arsenic, selenium, cadmium, antimony, and barium in

More information

In-Situ Analysis of Traces, Minor and Major Elements in Rocks and Soils with a Portable XRF Spectrometer*

In-Situ Analysis of Traces, Minor and Major Elements in Rocks and Soils with a Portable XRF Spectrometer* In-Situ Analysis of Traces, Minor and Major Elements in Rocks and Soils with a Portable XRF Spectrometer* Anthony Thomas 1, Joachim Heckel 1, and Dirk Wissmann 1 Search and Discovery Article #41836 (2016)

More information

GLANCING INCIDENCE XRF FOR THE ANALYSIS OF EARLY CHINESE BRONZE MIRRORS

GLANCING INCIDENCE XRF FOR THE ANALYSIS OF EARLY CHINESE BRONZE MIRRORS 176 177 GLANCING INCIDENCE XRF FOR THE ANALYSIS OF EARLY CHINESE BRONZE MIRRORS Robert W. Zuneska, Y. Rong, Isaac Vander, and F. J. Cadieu* Physics Dept., Queens College of CUNY, Flushing, NY 11367. ABSTRACT

More information

T.V. Vorburger, J.F. Song, T.B. Renegar, and A. Zheng January 23, 2008

T.V. Vorburger, J.F. Song, T.B. Renegar, and A. Zheng January 23, 2008 NIST SURFACE ROUGHNESS AND STEP HEIGHT CALIBRATIONS: Measurement Conditions and Sources of Uncertainty T.V. Vorburger, J.F. Song, T.B. Renegar, and A. Zheng January 23, 2008 The property of surface roughness

More information

APPENDIX C. Modified ASTM C 1260 Test Method to Evaluate Aggregate Reactivity in Presence of Deicer Solutions

APPENDIX C. Modified ASTM C 1260 Test Method to Evaluate Aggregate Reactivity in Presence of Deicer Solutions APPENDIX C Modified ASTM C 1260 Test Method to Evaluate Aggregate Reactivity in Presence of Deicer Solutions INTERIM TEST PROTOCOL Modified ASTM C 1260 Test Method to Evaluate Aggregate Reactivity in Presence

More information

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction 1. Application 1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction Parameters and Codes: EDB and DBCP, whole water recoverable, O-3120-90 Parameter (µg/l)

More information

NIST ELECTROSTATIC FORCE BALANCE EXPERIMENT

NIST ELECTROSTATIC FORCE BALANCE EXPERIMENT NIST ELECTROSTATIC FORCE BALANCE EXPERIMENT John A. Kramar, David B. Newell, and Jon R. Pratt National Institute of Standards and Technology, Gaithersburg, MD, USA We have designed and built a prototype

More information

Abstract No. 48. Multi-step oxidation of mineral samples by borate fusion Dirk Töwe, HRT Fusion GmbH

Abstract No. 48. Multi-step oxidation of mineral samples by borate fusion Dirk Töwe, HRT Fusion GmbH Abstract No. 48 Multi-step oxidation of mineral samples by borate fusion Dirk Töwe, HRT Fusion GmbH Service laboratories performing borate fusion sample preparation for XRF analysis are exposed to a very

More information

Standard Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation 1

Standard Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation 1 Designation: C 653 97 Standard Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation 1 This standard is issued under the fixed designation C 653; the number

More information

ANALYSIS OF LOW DENSITY PARTICLES USING DIFFERENTIAL CENTRIFUGAL SEDIMENTATION

ANALYSIS OF LOW DENSITY PARTICLES USING DIFFERENTIAL CENTRIFUGAL SEDIMENTATION ANALYSIS OF LOW DENSITY PARTICLES USING DIFFERENTIAL CENTRIFUGAL SEDIMENTATION Conventional Centrifugal Methods Centrifugal sedimentation of particles suspended in a fluid is a well known method (1, 2)

More information

FUNDAMENTAL PARAMETER METHOD FOR THE LOW ENERGY REGION INCLUDING CASCADE EFFECT AND PHOTOELECTRON EXCITATION

FUNDAMENTAL PARAMETER METHOD FOR THE LOW ENERGY REGION INCLUDING CASCADE EFFECT AND PHOTOELECTRON EXCITATION Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 511 FUNDAMENTAL PARAMETER METHOD FOR THE LOW ENERGY REGION INCLUDING CASCADE EFFECT AND PHOTOELECTRON

More information

BORON IN GLASS DETERMINATION USING WDXRF

BORON IN GLASS DETERMINATION USING WDXRF 269 ABSTRACT BORON IN GLASS DETERMINATION USING WDXRF Alexander Seyfarth Bruker AXS Inc., 5465 East Cheryl Parkway, Madison, Wisconsin 53711-5373 The application of wavelength-dispersive XRF to the analysis

More information

SUPPORTING INFORMATION

SUPPORTING INFORMATION SUPPORTING INFORMATION USEFULNESS OF A DUAL MACRO AND MICRO ENERGY DISPERSIVE X-RAY FLUORESCENCE SPECTROMETER TO DEVELOP QUANTITATIVE METHODOLOGIES FOR HISTORIC MORTAR AND RELATED MATERIALS CHARACTERIZATION

More information

Essentials of expressing measurement uncertainty

Essentials of expressing measurement uncertainty Essentials of expressing measurement uncertainty This is a brief summary of the method of evaluating and expressing uncertainty in measurement adopted widely by U.S. industry, companies in other countries,

More information

What is measurement uncertainty?

What is measurement uncertainty? What is measurement uncertainty? What is measurement uncertainty? Introduction Whenever a measurement is made, the result obtained is only an estimate of the true value of the property being measured.

More information

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY Copyright -International Centre for Diffraction Data 2010 ISSN 1097-0002 CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY B. Chyba, M. Mantler, H. Ebel, R. Svagera Technische Universit Vienna,

More information

Chapter 8: Sampling, Standardization, and Calibration

Chapter 8: Sampling, Standardization, and Calibration Chapter 8: Sampling, Standardization, and Calibration A chemical analysis uses only a small fraction of the available sample, the process of sampling is a very important operation. Knowing how much sample

More information

á733ñ LOSS ON IGNITION

á733ñ LOSS ON IGNITION 370 á731ñ Loss on Drying / Physical Tests USP 37 or less of mercury. At the end of the heating period, admit dry air to the heating chamber, remove the bottle, and with the capillary stopper still in place

More information

Reference Materials for Trade and Development: Quality and Comparability

Reference Materials for Trade and Development: Quality and Comparability Reference Materials for Trade and Development: Quality and Comparability A. Introduction Scientific measurements are a basic input to decisions made in many areas of human activity. In particular, physical

More information

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company Key Analytical Issues: Sample Preparation, Interferences and Variability Tim Shelbourn, Eli Lilly and Company Presentation Outline Sample preparation objectives and challenges Some common interferences

More information

Analysis of Cadmium (Cd) in Plastic Using X-ray Fluorescence Spectroscopy

Analysis of Cadmium (Cd) in Plastic Using X-ray Fluorescence Spectroscopy Analysis of Cadmium (Cd) in Plastic Using X-ray Fluorescence Spectroscopy Hiroshi Onodera Application & Research Center, JEOL Ltd. Introduction um, PBB and PBDE) are subject to usage restrictions in Europe.

More information

Quantitative XRF Analysis. algorithms and their practical use

Quantitative XRF Analysis. algorithms and their practical use Joint ICTP-IAEA School on Novel Experimental Methodologies for Synchrotron Radiation Applications in Nano-science and Environmental Monitoring Quantitative XRF Analysis algorithms and their practical use

More information

Time-Resolved μ-xrf and Elemental Mapping of Biological Materials

Time-Resolved μ-xrf and Elemental Mapping of Biological Materials 296 Time-Resolved μ-xrf and Elemental Mapping of Biological Materials K. Tsuji 1,2), K. Tsutsumimoto 1), K. Nakano 1,2), K. Tanaka 1), A. Okhrimovskyy 1), Y. Konishi 1), and X. Ding 3) 1) Department of

More information

MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT

MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT Copyright JCPDS - International Centre for Diffraction Data 2003, Advances in X-ray Analysis, Volume 46. 363 MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT J.E. Fernández, V.

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 FUGRO SUHAIMI LIMITED Chemical and Calibration Laboratories King Abdul-Aziz Port Road PO Box 2165 Dammam, Kingdom of Saudi Arabia 31451 Mohammed B. Hameed Phone:

More information

AUTOMATED TEMPLATE MATCHING METHOD FOR NMIS AT THE Y-12 NATIONAL SECURITY COMPLEX

AUTOMATED TEMPLATE MATCHING METHOD FOR NMIS AT THE Y-12 NATIONAL SECURITY COMPLEX AUTOMATED TEMPLATE MATCHING METHOD FOR NMIS AT THE Y-1 NATIONAL SECURITY COMPLEX J. A. Mullens, J. K. Mattingly, L. G. Chiang, R. B. Oberer, J. T. Mihalczo ABSTRACT This paper describes a template matching

More information

Preparation and Certification of IRMM-081a and IRMM-086 Spike Isotopic Reference Materials

Preparation and Certification of IRMM-081a and IRMM-086 Spike Isotopic Reference Materials Preparation and Certification of IRMM-081a and IRMM-086 Spike Isotopic Reference Materials A. Verbruggen, R. Eykens, F. Kehoe, H. Kühn, S. Richter, Y. Aregbe EUR 22944 EN - 2007 The mission of the IRMM

More information

Uncertainty of Measurement

Uncertainty of Measurement Uncertainty of Measurement Contents Uncertainty of Measurement.... 3 Uncertainty of Measurement and Measurement Error.... 4 Measuring Uncertainty.... 5 Coverage factor k...6 Factors Affecting Uncertainty....

More information

Worldwide Open Proficiency Test for X Ray Fluorescence Laboratories PTXRFIAEA13. Determination of Major, Minor and Trace Elements in a Clay Sample

Worldwide Open Proficiency Test for X Ray Fluorescence Laboratories PTXRFIAEA13. Determination of Major, Minor and Trace Elements in a Clay Sample Worldwide Open Proficiency Test for X Ray Fluorescence Laboratories PTXRFIAEA13 Determination of Major, Minor and Trace Elements in a Clay Sample IAEA Laboratories, Seibersdorf November 2017 CONTENTS

More information

APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY

APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY Table of Contents 1. SCOPE... 2 2. REFERENCES... 2 3. TERMS AND DEFINITIONS... 2 4. BACKGROUND... 4 5. EVALUATION OF MEASUREMENT UNCERTAINTY POLICY... 5

More information

NATIONAL ASSOCIATION OF TESTING AUTHORITIES (NATA) REQUIREMENTS FOR ACCREDITATION OF ICP-MS TECHNIQUES

NATIONAL ASSOCIATION OF TESTING AUTHORITIES (NATA) REQUIREMENTS FOR ACCREDITATION OF ICP-MS TECHNIQUES NATIONAL ASSOCIATION OF TESTING AUTHORITIES (NATA) REQUIREMENTS FOR ACCREDITATION OF ICP-MS TECHNIQUES The National Association of Testing Authorities (NATA) requirements for accreditation have undergone

More information

IMPROVEMENT OF DETECTION LIMITS OF A PORTABLE TXRF BY REDUCING ELECTRICAL NOISE

IMPROVEMENT OF DETECTION LIMITS OF A PORTABLE TXRF BY REDUCING ELECTRICAL NOISE Copyright JCPDS-International Centre for Diffraction Data 2012 ISSN 1097-0002 281 IMPROVEMENT OF DETECTION LIMITS OF A PORTABLE TXRF BY REDUCING ELECTRICAL NOISE Susumu Imashuku 1, Deh Ping Tee 1, Yasukazu

More information

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

2.1. Accuracy, n- how close the indication of the thermometer is to the true value. AASHTO Accreditation Policy and Guidance on Thermometer Selection and Records Revised: January 25, 2018 Revision #: 0 1. Objective 1.1. The purpose of this document is to clearly define acceptance criteria

More information

TNI V1M Standard Update Guidance on Detection and Quantitation

TNI V1M Standard Update Guidance on Detection and Quantitation TNI V1M4 2016 Standard Update Guidance on Detection and Quantitation GUID-3-109-Rev0 January 30, 2019 This material represents the opinion of its authors. It is intended solely as guidance and does not

More information

Measurement uncertainty and legal limits in analytical measurements

Measurement uncertainty and legal limits in analytical measurements UNCERTAINTY Measurement uncertainty and legal limits in analytical measurements MIRELLA BUZOIANU, Reference Materials Laboratory, National Institute of Metrology (INM), Bucharest, Romania 1 Introduction

More information

COMBINED ELEMENTAL XRF AND PHASE XRD ANALYSES OF A METEORITE

COMBINED ELEMENTAL XRF AND PHASE XRD ANALYSES OF A METEORITE Copyright JCPDS-International Centre for Diffraction Data 2016 ISSN 1097-0002 85 COMBINED ELEMENTAL XRF AND PHASE XRD ANALYSES OF A METEORITE Frantessa Tañeza-Casco, Thomas Witzke, Nicholas Norberg, PANalytical

More information

The Uncertainty of Reference Standards

The Uncertainty of Reference Standards 2009 Cerilliant Corporation The Uncertainty of Reference Standards A Guide to Understanding Factors Impacting Uncertainty, Uncertainty Calculations and Vendor Certifications Authors: Ning Chang PhD, Isil

More information

REALIZATION OF AN ASYMMETRIC MULTILAYER X-RAY MIRROR

REALIZATION OF AN ASYMMETRIC MULTILAYER X-RAY MIRROR Copyright(c)JCPDS-International Centre for Diffraction Data 2000,Advances in X-ray Analysis,Vol.43 218 REALIZATION OF AN ASYMMETRIC MULTILAYER X-RAY MIRROR S. M. Owens Laboratory for High Energy Astrophysics,

More information

ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS

ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS 302 ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS M. Song 1, K. Mitsuishi 1, M. Takeguchi 1, K. Furuya 1, R. C. Birtcher 2 1 High Voltage Electron Microscopy Station, National

More information

The Uncertainty of Reference Standards A Guide to Understanding Factors Impacting Uncertainty, Uncertainty Calculations, and Vendor Certifications

The Uncertainty of Reference Standards A Guide to Understanding Factors Impacting Uncertainty, Uncertainty Calculations, and Vendor Certifications The Uncertainty of Reference Standards A Guide to Understanding Factors Impacting Uncertainty, Uncertainty Calculations, and Vendor Certifications Kevin Gates, Ning Chang, Isil Dilek, Huahua Jian, Sherri

More information

The Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

The Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS A P P L I C AT I O N N O T E ICP - Mass Spectrometry Authors: Lee Davidowski Chady Stephan PerkinElmer, Inc. Shelton, CT The Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical

More information

Subject: Evaluation of the Equation for Soil Composite June 20, 2003 Internal Memo to IMPROVE Staff from Bob Eldred

Subject: Evaluation of the Equation for Soil Composite June 20, 2003 Internal Memo to IMPROVE Staff from Bob Eldred Subject: Evaluation of the Equation for Soil Composite June 2, 23 Internal Memo to IMPROVE Staff from Bob Eldred Summary. The purpose of this report is to determine if we wish to revise the current equation

More information

CERTIFICATE OF. Single Analyte Mass Spec Solution ± 0.1 µg/ml g/ml (measured at 20 ± 4 ºC)

CERTIFICATE OF. Single Analyte Mass Spec Solution ± 0.1 µg/ml g/ml (measured at 20 ± 4 ºC) CERTIFICATE OF ANALYSIS 300 Technology Drive Christiansburg, VA 24073. USA inorganicventures.com tel: 800.669.6799. 540.585.3030 fax: 540.585.3012 info@inorganicventures.com 1.0 ACCREDITATION / REGISTRATION

More information

The first model was based only on the CANBERRA information which we. drawing. Canberra refused any other information.

The first model was based only on the CANBERRA information which we. drawing. Canberra refused any other information. Experimental and Monte Carlo determination of Gamma Spectrometry Efficiency Pavel Dryak, Petr Kovář Czech Metrology Institute February 2009 Leading motive of our testing The producer send the drawing after

More information

The role of LSD spikes in safeguarding nuclear reprocessing plants R Wellum, Y Aregbe, A Verbruggen, S Richter

The role of LSD spikes in safeguarding nuclear reprocessing plants R Wellum, Y Aregbe, A Verbruggen, S Richter The role of LSD spikes in safeguarding nuclear reprocessing plants R Wellum, Y Aregbe, A Verbruggen, S Richter Institute for Reference Materials and Measurements (IRMM) Geel, Belgium http://www.irmm.jrc.be

More information

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis MT-0.6026 Electron microscopy Scanning electron microscopy and electron probe microanalysis Eero Haimi Research Manager Outline 1. Introduction Basics of scanning electron microscopy (SEM) and electron

More information

Determinktion of Iodine to Compliment Mass Spectrometric Measurements

Determinktion of Iodine to Compliment Mass Spectrometric Measurements I D A H O NATIONAL E N G I N E E R I N G LABORATORY 1NEL-94/0068 November 1994 Determinktion of Iodine to Compliment Mass Spectrometric Measurements =>Loc/r/leed fdahotechnologies Company Work performed

More information

ADVANTAGES AND DISADVANTAGES OF BAYESIAN METHODS FOR OBTAINING XRF NET INTENSITIES

ADVANTAGES AND DISADVANTAGES OF BAYESIAN METHODS FOR OBTAINING XRF NET INTENSITIES 187 188 ADVANTAGES AND DISADVANTAGES OF BAYESIAN METHODS FOR OBTAINING XRF NET INTENSITIES ABSTRACT W. T. Elam, B. Scruggs, F. Eggert, and J. A. Nicolosi EDAX, a unit of Ametek Inc., 91 McKee Drive, Mahwah,

More information

QSM 5.1 FAQs. For a test with a recommended maximum holding time measured in hours, the holding time shall be tracked by the hour.

QSM 5.1 FAQs. For a test with a recommended maximum holding time measured in hours, the holding time shall be tracked by the hour. QSM 5.1 FAQs DoD ELAP FAQ Holding Time - Hours For a test with a recommended maximum holding time measured in hours, the holding time shall be tracked by the hour. For example, an exceedance of holding

More information