Development of the Thermo Scientific Dionex IonPac AS26 Column for Haloacetic Acid Analysis

Size: px
Start display at page:

Download "Development of the Thermo Scientific Dionex IonPac AS26 Column for Haloacetic Acid Analysis"

Transcription

1 Development of the Thermo Scientific Dionex IonPac AS Column for aloacetic ong Lin, Kannan Srinivasan, and Chris Pohl, Thermo Fisher Scientific, Sunnyvale, CA, USA Introduction aloacetic acids are a group of disinfection byproducts resulting from the reaction between the naturally occurring organic matters and the disinfectants used during water treatment. These disinfection byproducts pose potential health hazard due to longterm exposure and are currently regulated by EPA. The Stage Disinfection/Disinfection Byproduct rule sets a maximum contamination level of 0 ppb for AA, which includes monochloroacetic acid, monobromoacetic acid, dichloroacetic acid, dibromoacetic acid and trichloroacetic acid (Table ). The predominant method for AA analysis is U.S. EPA Method., a GC/electron capture detection (ECD) method. It is a timeconsuming and laborintensive process, often resulting in operational errors. U.S. EPA Method describes a suppressed ion chromatography (IC) MS or MS/MS detection method using direct injection and matrix elimination. The MS detection is required to selectively detect coeluting species. The work presented here describes the development of a new IC separation column (Thermo Scientific Dionex IonPac AS) for haloacetic acid analysis by utilizing amineepoxide hyperbranch chemistry. Various synthesis strategies for improving the haloacetic acid resolution and quantitation are shown, and a twodimensional (D) method allowing sensitive conductivity detection is described. Table. What Are AAs? Acid Abbreviation Chemical Formula pka Boiling Point C Monochloroacetic Acid MCAA* ClC CO.. Dichloroacetic Acid DCAA* Cl CCO. Trichloroacetic Acid TCAA* Cl CCO 0.. Monobromoacetic Acid MBAA* BrC CO. 0 Dibromoacetic Acid DBAA* Br CCO A Tribromoacetic Acid TBAA Br CCO 0. Bromochloroacetic Acid BCAA BrClCCO A 0. Dibromochloroacetic Acid DBCAA Br ClCCO A A Dichlorobromoacetic Acid DCBAA Cl BrCCO A A *MCAA, DCAA, TCAA, MBAA, DBAA are collectively referred to as AA

2 aloacetic Acid Methods U.S. EPA Method. requires liquidliquid microextraction and derivatization before GC/ECD analysis. A 0 ml sample is adjusted to p 0., then extracted either with methyl tertbutyl ether (MTBE) or tertamyl methyl ether. AAs are converted to their methyl esters by adding acidic methanol and heating for two hours. The sample is separated from the acidic methanol by adding a concentrated aqueous solution of sodium sulfate, and is then neutralized with saturated solution of sodium bicarbonate. Analysis using GC/ECD requires 0 min. This method provides good selectivity, low Minimum Detection Limits (MDLs) from μg/l for AA, and a wide applicable concentration range from 0. 0 μg/l. owever, it requires sample pretreatment that is time consuming, labor intensive, and subject to multiple procedural errors, with recoveries ranging from 0% for AA. U.S. EPA Method using suppressed ion chromatography with MS or MSMS detection is a direct injection method, with no need for liquidliquid extraction, sample pretreatment, or derivatization. It uses a fully automated matrix diversion setup to eliminate column overloading due to highionicstrength matrices, and coelution is not an issue since MS is a selective detector. ecoveries are more than 0%. Figure shows the typical separation of nine haloacetic acid anions using a Dionex IonPac AS column. MBAA, CDBAA, and TBAA degrade readily at high p, so to minimize degradation, the separation is performed at C. Chlorite and MCAA coelute under these conditions. FIGUE. Analysis of AA using the Dionex IonPac AS column at C. esults and Discussion Polmer Formation Figure illustrates the schematics of the stepgrowth electrostaticgraft porous polymeric substrate. The ionexchange site is highlighted. FIGUE. Stepgrowth electrostaticgraft porous polymeric substrate. Figure illustrates the basic chemistry behind amineepoxide condensation polymer chemistry. By using a : molar ratio of primary amine and a diepoxide, it is possible to synthesize a predominantly linear polymer with residual tertiary amine functionality. If the condensation polymer is formed in the presence of an anionic surface, the resulting polymer will form a coating over the entire surface. The residual tertiary amine sites can be used for growth of hyperbranched polymer chains with anionexchange groups located at regular distances along the growing chain. FIGUE. ypothetical product of : ratio (diepoxide:amine)..0 MCAA O DBAA.00 Peaks:. MCAA. MBAA. DCAA. BCAA. DBAA. TCAA. BDCAA. CDBAA. TBAA O O O O + ( O O ) n 00 Concentration:.00 mm K Development of the Thermo Scientific Dionex IonPac AS Column for aloacetic

3 Figure illustrates a representative section of the stationary phase substrate surface after the initial reaction in the presence of the substrate, forming the basement layer followed by two subsequent reaction cycles of a diepoxide followed by a primary amine. This alternates in the following sequence: diepoxide, water rinse, primary amine, water rinse, diepoxide, water rinse, primary amine, and a final water rinse. With each reaction cycle (each cycle consisting of diepoxide followed by primary amine), the number of quaternary sites in the growing polymer doubles. Substantial capacity can be created with three and four reaction cycles. At the end of each reaction cycle, residual secondary amine groups remain available for further reactions. Figure illustrates the effect of high concentration of epoxide on the column capacity and selectivity. This phase shows very high capacity and excellent separation for the early eluting peaks. owever, the overall run time is too long. FIGUE. Example of high capacity phase and its impact on AA separation.. O % Diepoxide 0 mm Concentration: 0.00 mm K Peaks:. MCAA 00 µg/l. MBAA 00. DCAA 00. BCAA 00. DBAA 00. TCAA 00. BDCAA 00 FIGUE. Layer after diepoxide and amine treatment. Crosslink 0% Diepoxide ClO 0 mm O.00 Concentration:.00 mm K Sulfonated esin Surface Figure illustrates the effect of temperature during the basement layer synthesis on the separation of the early eluting peaks. The separation between bromate and MBAA improves when higher temperature is used. The separation between the chlorite and MCAA peak also improves at higher temperature. A new invial synthesis strategy was used for the Dionex IonPac AS columns. A basement layer was applied to the sulfonated resin by mixing the diepoxide/amine solution mixture (: mole ratio of epoxide to amine) with the resin (sulfonated) at 0 C for 0 min. This was functionalized by reacting the diepoxide with the resulting resin at C for h then treating the resin with the same amine mixture solution at C for h. Selectivity Figure illustrates the effect of epoxide concentration on the column selectivity. As the epoxide concentration increases, the resolution between bromate and MBAA, nitrite and DBAA improves. FIGUE. Selectivity optimization using different basement layer reaction conditions..0 C Column: Prototypes Eluent: K Gradient Flow ate: 0. ml/min Inj. Volume: 0 µl BrO Column Temp.: C Suppressor: Thermo Scientific Dionex ASS 00, mm 0. Current: ma (recycle mode) Peaks:. MCAA 00 µg/l.0 0 C. MBAA 00 BrO 0. 0 FIGUE. Effect of the diepoxide concentration on selectivity BrO Concentration:.00 mm K O.00 % Diepoxide Peaks:. MCAA 00 µg/l. MBAA 00. DCAA 00. BCAA 00. DBAA 00. TCAA 00. BDCAA 00. CDBAA 00. TBAA 00 0% Diepoxide BrO O Concentration:.00 mm K

4 Figure illustrates the separation using the new Dionex IonPac AS column. All nine haloacetic acid anions are separated from the matrix anions. FIGUE. Separation of AAs using the new Dionex IonPac AS column...00 Column: Dionex IonPac AS 0 mm Eluent: K Gradient Flow ate: 0. ml/min Inj. Volume: 0 µl Column Temp.: C Suppressor: Dionex ASS 00, mm Current: ma (recycle mode) Peaks:. MCAA. MBAA. DCAA. BCAA. DBAA. TCAA. BDCAA. CDBAA. TBAA Ions of interest are diverted to a concentrator column after suppression in the first dimension and focused. The hydroxide eluent is converted to DI water by the suppressor, providing an ideal environment for focusing or concentrating the ions of interest. Analysis is performed in the second dimension using a column with a smaller crosssectional area, yielding enhanced sensitivity. For example, the crosssectional area of a mm column is one sixteenth the area of a mm column, providing a sensitivity enhancement factor of ~. Analysis in the second dimension using a different chemistry provides complementary retention, leading to enhanced selectivity. This method can be automated easily using the Dionex ICS000/ICS000 systems (Figure ). Concentration:.00 mm FIGUE. Instrumental setup for the matrix elimination ion chromatography (MEIC). Matrix Elimination Ion Chromatography (MEIC) A variety of methods for determining trace levels of contaminants in water are commonly employed. Samples with low levels of matrix ions (e.g., ultrapure water [UPW]) are typically analyzed using preconcentration or largevolume direct injections. For samples with high levels of matrix ions (e.g., drinking water, wastewater), preconcentration or largevolume direct injection may not be possible because the matrix ions may coelute with species of interest or may elute species of interest, leading to recovery and integration issues due to band broadening. Sample pretreatment steps using solidphase extraction (SPE) cartridges may be used to remove matrix interferences (e.g., a silver form cationexchange resin used to remove high levels of chloride). Such offline SPE methods are labor intensive, and multiple cartridges may be needed, adding cost. Matrix elimination is an automated method in which the highconcentration matrix ions are separated from the analytes using a mm firstdimension column and diverted to waste. A larger loop volume than the standard approach can be used because the capacity and selectivity of the analytical column in the first dimension dictates the recovery, and the analyte of interest is analyzed in the second dimension. st Dimension nd Dimension Large Loop Load Inject Injection Valve Pump st Dimension Column ( mm) External Water Suppressor EG Autosampler CD CD To EG Degas in Transfer to D Load Concentrator Diverter Valve External Water Injection Valve Pump Concentrator Column (UTACULP) nd Dimension Column ( mm) EG CD CD Suppressor To EG Degas in Development of the Thermo Scientific Dionex IonPac AS Column for aloacetic

5 Figure 0 shows the analysis of nine haloacetic acid anions using the twodimensional matrixelimination ion chromatography, both in the reagent water (black trace, A) and the high ionic water (IW, blue trace, B), containing 00 mg/l each of Cl, CO, and SO and 0 mg/l each of as O and P as PO. The top chromatograms show the firstdimension analysis using a Dionex IonPac ASA mm column and the bottom chromatograms show the seconddimension analysis using a Dionex IonPac AS mm column. etention time shifts and peak broadening observed in the firstdimensional IW sample are absent in the second dimension. Excellent recovery is observed for all AAs. Conclusion The Dionex IonPac AS column was developed by optimizing amine epoxide reaction conditions Excellent resolution of AAs was achieved in the presence of inorganic matrix ions Preliminary studies with the MEIC methodology allowed analysis of AA in the presence of matrix ions with suppressed conductivity detection Matrix diversion and selective concentration of AA species in the first dimension Separation and enhanced detection by suppressed conductivity detection in the second dimension FIGUE 0. MEIC analysis of AA in reagent water and high ionic water (IW). B A First Dimension Second Dimension B A ecovery >0% for AAs First Dimension Column: Dionex IonPac ASA, mm Flow ate:.0 ml/min Column Temp.: C Inj. Volume: 000 µl Suppressor: Dionex ASS 00, mm Current: ma (ecycle) Second Dimension Column: Dionex IonPac AS, mm Flow ate: 0. ml/min Suppressor: Dionex ASS 00, mm Current: ma (ecycle) Column Temp.: C Concentrator: Dionex IonPac UTACLP Samples: A) AA in DI water B) AA in IW Peaks:. MCAA 00 µg/l. MBAA 00. DCAA 00. BCAA 00. DBAA 00. TCAA 00. BDCAA 00. CDBAA 00. TBAA 00 0 Thermo Fisher Scientific, Inc. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Dionex Products: Titan Way, PO Box 0, Sunnyvale, CA 00, (0) 000 orth America: U.S./Canada () 00 South America: Brazil () 0 Europe: Austria (), Benelux () 0 () Denmark () 0 0, France () 0 0 0, Germany () 0 Ireland () 00, Italy () 0, Sweden () 0, Switzerland () 0, United Kingdom () Asia Pacific: Australia () 0, China (), India (), Japan (), Korea () 0, Singapore () 0, Taiwan () LP 0 /

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000 Evaluation of Various Anion-Exchange Chemistries for the Analysis of Haloacetic Acids in Drinking Water Using -D Matrix Elimination Ion Chromatography and Suppressed Conductivity Detection White Paper

More information

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection columns IonPac AS Anion-Exchange Column The IonPac AS is a highcapacity, hydroxide-selective anion exchange column designed for separation of haloacetic acids (HAAs) and bromate in drinking water prior

More information

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS4A Anion-Exchange Column Product Specifications Thermo Scientific Dionex IonPac AS4A anion-exchange column is designed for the separation of haloacetic

More information

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column Chromatography Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS column is a high-capacity, hydroxide-selective, anion-exchange column

More information

The use of 2-D IC for the determination of Haloacetic Acids in Drinking Water

The use of 2-D IC for the determination of Haloacetic Acids in Drinking Water The use of 2-D IC for the determination of Haloacetic Acids in Drinking Water Rong Lin, Brian Deborba, Pranathi Perati, Richard Jack, Chris Pohl, Kannan Srinivasan Notes page NEMC Topics in Drinking Water

More information

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water Thermo Scientific Dionex Ion Chromatography Solutions Global water safety bromate analysis in drinking water Safe drinking water public health assurance As a vital limited resource required for survival,

More information

Ion Chromatography: Green Chemistry for a Green Environment. Ken Kirkbride Somerset, New Jersey October 12, 2011

Ion Chromatography: Green Chemistry for a Green Environment. Ken Kirkbride Somerset, New Jersey October 12, 2011 Ion Chromatography: Green Chemistry for a Green Environment Ken Kirkbride Somerset, New Jersey October 12, 2011 Ion Chromatography Ion Chromatography is an analytical technique that utilizes ion exchange

More information

Thermo Scientific. Anion-Exchange Column

Thermo Scientific. Anion-Exchange Column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS9-µm Anion-Exchange Column Product Specifications The Themo Scientific Dionex IonPac AS9-µm high-capacity, hydroxide-selective, anion-exchange column is

More information

columns IonPac AS22 Anion-Exchange Column

columns IonPac AS22 Anion-Exchange Column columns IonPac AS Anion-Exchange Column The IonPac AS is a carbonate based anion-exchange column designed for the determination of inorganic anions and low-molecular-weight organic acids including fluoride,

More information

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory Customer Application Note: 114 Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory Sébastien N. Ronkart, Ph.D.; Société wallonne des eaux, rue de la

More information

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography Yan Liu, Zhongqing Lu, and Chris Pohl, Thermo Fisher Scientific, Sunnyvale, CA USA Overview Purpose: In this work, new high-pressure

More information

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column Chromatography Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS high-capacity, carbonate based anion-exchange column is designed for

More information

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography Harpreet Dhillon and John Statler Thermo Fisher Scientific, Sunnyvale, CA, USA Application Note 11 Introduction

More information

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS anion-exchange column is designed for the fast analysis of inorganic

More information

Determination of trace anions in concentrated hydrofluoric acid

Determination of trace anions in concentrated hydrofluoric acid APPLICATION NOTE 78 Determination of trace anions in concentrated hydrofluoric acid Authors Archava Siriraks Thermo Fisher Scientific, Sunnyvale, CA Keywords HF, ICS-5000 +, IonPac AS10, IonPac AC10, ion

More information

columns IonPac AS17-C Anion Exchange Column

columns IonPac AS17-C Anion Exchange Column columns IonPac AS-C Anion Exchange Column The IonPac AS-C is a hydroxide-selective anion exchange column designed for fast gradient separation of inorganic anions. The key application for the AS-C column

More information

Dionex IonPac AS28-Fast-4µm column

Dionex IonPac AS28-Fast-4µm column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS-Fast-4µm Columns Product Specifications The Thermo Scientific Dionex IonPac AS-Fast-4µm column is a high-capacity, hydroxide-selective anionexchange column

More information

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production Thunyarat Phesatcha, Suparerk Tukkeeree, Jeff Rohrer 2 Thermo

More information

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System arbara Shao, Frank Hoefler, Maria Rey, and Linda Lopez, Thermo Fisher Scientific,

More information

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems Yan Liu, Zhongqing Lu, and Chris Pohl; Thermo Fisher Scientific, Sunnyvale, CA USA Overview

More information

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes columns Thermo Scientific Dionex IonPac AS Anion-Exchange Column Isocratic Separation of Sulfur Species and Inorganic Anions Using the Dionex IonPac AS Column. Fluoride. Bromate. Chloride. Nitrite. Bromide.

More information

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System Application Update 55 Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free System Introduction Hydrogen peroxide is an essential chemical in the fabrication

More information

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection Barbara Shao, Terri Christison, Fei Pang, Cathy Tanner, and Frank Hoefler, Thermo Fisher Scientific, Sunnyvale,

More information

anion-exchange column

anion-exchange column columnsionpac ASA Anion-Exchange Column The IonPac ASA is a carbonateselective anion-exchange column designed for the fast separation of inorganic anions, including fluoride, chlorite, bromate, chloride,

More information

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device Determination of Bromate in Bottled Mineral Water Using the CRD 00 Carbonate Removal Device Thunyarat Phesatcha, Weerapong Worawirunwong, and Jeff Rohrer Thermo Fisher Scientific, Bangkok, Thailand; Thermo

More information

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples Application Note 79 Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples INTRODUCTION Cow s milk is of particular dietary value to infants,

More information

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection Terri Christison, Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA Overview

More information

columns IonPac AS18 Anion-Exchange Columns

columns IonPac AS18 Anion-Exchange Columns columns IonPac AS Anion-Exchange Columns The IonPac AS is a hydroxideselective anion-exchange column designed for the determination of inorganic anions and low-molecularweight organic acids including fluoride,

More information

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components APPLICATION UPDATE 157 Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components Authors Sumate Pengpumkiat, Weerapong Worawirunwong,

More information

Advances in Sample Preparation for Accelerated Solvent Extraction

Advances in Sample Preparation for Accelerated Solvent Extraction Advances in Sample Preparation for Accelerated Solvent Extraction SM Rahmat Ullah, Kannan Srinivasan, and Chris Pohl, Thermo Fisher Scientific, Sunnyvale, CA, USA Overview Purpose: To demonstrate the utility

More information

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

Determination of Inorganic Anions in Drinking Water by Ion Chromatography Determination of Inorganic s in Drinking Water by Ion Chromatography Peter Jackson Thermo Fisher Scientific Inc. Application Note Introduction The determination of common inorganic anions in drinking water

More information

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column chromatography Obtain excellent peak shapes for hydrophobic amines without the use of solvent using the Dionex IonPac CS CationExchange Column. Product Specifications Thermo Scientific Dionex IonPac CS

More information

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA New Stationary Phases for Solid-Phase Extraction Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA Overview Purpose: To develop five new polymer-based stationary

More information

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection Determination of Tartaric cid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection Suparerk Tukkeeree, Chanita Chantarasukon, and Jeff Rohrer Thermo Fisher Scientific, angkok,

More information

columns IonPac SCS 1 Silica Cation Separator

columns IonPac SCS 1 Silica Cation Separator columns IonPac SCS Silica Cation Separator The SCS Silica Cation Separator is designed for use with nonsuppressed conductivity detection, or single-column ion chromatography (SCIC). This column is particularly

More information

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC TECHNICAL NOTE 122 Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC Authors Terri Christison and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA,

More information

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Direct Determination of Small Organic Acids in Sea Water by IC-MS Direct Determination of Small Organic Acids in Sea Water by IC-MS Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA Application Note Key Words MSQ Plus Single Quadrupole Mass

More information

Research Associated with the Development of EPA Method 552.2

Research Associated with the Development of EPA Method 552.2 Research Associated with the Development of EPA Method 552.2 cerns over the toxic properties and explosive characteristics of diazomethane have prompted the EPA to investigate alternative derivatization

More information

Inline sample preparation for the determination of anions in sodium hydroxide

Inline sample preparation for the determination of anions in sodium hydroxide APPLICATION UPDATE 72331 Inline sample preparation for the determination of anions in sodium hydroxide Authors Hua Yang and Jeff Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA Keywords Sample preparation,

More information

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA Determination of Sub-μg/L Bromate in Municipal and Natural Mineral Waters Using Preconcentration with Two-Dimensional Ion Chromatography and Suppressed Conductivity Detection Brian DeBorba and Jeff Rohrer

More information

Utility of the Charge Detector in Ion Chromatography Applications

Utility of the Charge Detector in Ion Chromatography Applications Utility of the Charge Detector in Ion Chromatography Applications Mrinal K. Sengupta, Sheetal Bhardwaj, Kannan Srinivasan, Chris Pohl, and Purnendu K. Dasgupta Thermo Fisher Scientific, Sunnyvale, California,

More information

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Determination of Trace Cations in Power Plant Waters Containing Morpholine Application Note 8 Determination of Trace Cations in Power Plant Waters Containing Morpholine INTRODUCTION Morpholine and ammonium are used as additives in power plant waters. Morpholine acts as a corrosion

More information

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection Ian Acworth, Bruce Bailey, Paul Gamache, and John Waraska Thermo Fisher Scientific, Chelmsford, MA, USA Introduction

More information

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column Application Note 95 Determination of Hydrochloride Purity Using the Acclaim PA Column INTRODUCTION -based medications are prescribed for several heart and blood pressure indications. The fastacting formulations

More information

Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by HPLC Using a Mixed-Mode Weak Anion-Exchange Column

Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by HPLC Using a Mixed-Mode Weak Anion-Exchange Column Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by PLC Deanna C. urum, Brian M. De Borba, and Jeffrey S. Rohrer Dionex Corporation, Sunnyvale, CA, USA ITRDUCTI Peptides perform

More information

Office of Water (MLK 140) EPA Document No. 815-B September eidenbach Cincinna. nnati, Ohio

Office of Water (MLK 140) EPA Document No. 815-B September eidenbach Cincinna. nnati, Ohio METHOD 557: DETERMINATION OF HALOACETIC ACIDS, BROMATE, AND DALAPON IN DRINKING WATER BY ION CHROMATOGRAPHY ELECTROSPRAY IONIZATION TANDEM MASS SPECTROMETRY (IC-ESI-MS/MS) Andrew W. BreiB eidenbach Environmen

More information

Determination of Methylamine in Drug Products

Determination of Methylamine in Drug Products Determination of Methylamine in Drug Products Thunyarat Phesatcha, Suparerk Tukkeeree, and Jeff Rohrer 2 Thermo Fisher Scientific, Bangkok, Thailand; 2 Thermo Fisher Scientific, Sunnyvale, CA, USA Application

More information

Determination of Monochloroacetic Acid in Carbocisteine

Determination of Monochloroacetic Acid in Carbocisteine Determination of Monochloroacetic Acid in Carbocisteine Zhong Xinlin, Ye Mingli, Liang Lina, Xu Qun, and Jeffrey Rohrer Thermo Fisher Scientific, Shanghai, People s Republic of China; Thermo Fisher Scientific,

More information

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column Chromatography Thermo Scientific Anion-Exchange Column Product Specifications Attain the optimal resolution of organic acids and inorganic anions using the new Thermo Scientific Dionex IonPac AS11-HC-4µm

More information

Determination of urea in ultrapure water by IC-MS/MS

Determination of urea in ultrapure water by IC-MS/MS APPLICATION NOTE 72482 Determination of urea in ultrapure water by IC-MS/MS Authors Soon Fatt Lee, 1 Fiona Teh Hui Boon, 1 Chris Cheah Hun Teong, 1 and Jeff Rohrer 2 ¹Thermo Fisher Scientific, Singapore

More information

4. Ion chromatography (IC) 4.1. Educational aims and objectives

4. Ion chromatography (IC) 4.1. Educational aims and objectives 4. Ion chromatography (IC) 4.1. Educational aims and objectives Principles of ion chromatography method and instrumentation. Methods for ionic compounds analysis including ion chromatography and its subtypes.

More information

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Che Jinshui, 1 Deng Guifeng, 1 Liang Lina, 1 and Aaron Kettle, 2 1 Thermo Fisher Scientific (China)

More information

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry APPLICATION NOTE Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry AN43227 Antonella Guzzonato 1, Shona McSheehy Ducos

More information

Determination of Trace Anions in Organic Solvents

Determination of Trace Anions in Organic Solvents Application Note 8 Determination of Trace Anions in Organic Solvents INTRODUCTION In the manufacture of semiconductor materials, a great deal of attention is focused on minimizing sources of contamination.

More information

Analysis of Bulk Sodium Hypochlorite Feedstock for the Presence of HAAs and Other DBPs [Project #4412]

Analysis of Bulk Sodium Hypochlorite Feedstock for the Presence of HAAs and Other DBPs [Project #4412] Analysis of Bulk Sodium Hypochlorite Feedstock for the Presence of HAAs and Other DBPs [Project #4412] ORDER NUMBER: 4412 DATE AVAILABLE: April 2013 PRINCIPAL INVESTIGATORS: Gary L. Emmert, Paul S. Simone

More information

Determination of haloacetic acid in water for human consumption by UPLC-MS/MS

Determination of haloacetic acid in water for human consumption by UPLC-MS/MS Determination of haloacetic acid in water for human consumption by Paula S. Rosa, Margarida S. Romão, Georgina S. Felisberto Laboratório de Análises do Instituto Superior Técnico, Universidade de Lisboa,

More information

Determination of Adsorbable Organic Halogen in Wastewater

Determination of Adsorbable Organic Halogen in Wastewater Determination of Adsorbable Organic Halogen in Wastewater Jingli Hu, Jeff Rohrer, and Kirk Chassaniol Thermo Fisher Scientific, Sunnyvale, CA The world leader in serving science Outline AOX (Adsorbable

More information

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance Columns Reduce Analysis Time; Reduce System Maintenance 0 YEARS Turning Visions into Reality www.restek.com 00-- --00 and Fused Silica Columns Detect and confirm 0 common organochlorine pesticides simultaneously.

More information

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s columns I o n P a c AS and AS-H C Anion-E x c h a n g e C o l u m n s The IonPac AS anion-exchange column provides fast profiling of inorganic anions and organic acid anions using sodium hydroxide or potassium

More information

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents Marco Karsten, Bas, Dolman, Giovanni Maio, Frank Steiner, Holger Franz, Frank Arnold and Remco Swart LC Packings,

More information

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column chromatography Separate a wide variety of inorganic anions and organic acids using the Dionex IonPac AS and AS-HC Anion-Exchange Columns with potassium hydroxide gradients. Product Specifications Thermo

More information

Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column

Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column 38 LCGC LCGC NORTH NORTH AMERICA VOLUME NUMBER FEBRUARY 4 4 www.chromatographyonline.com Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column The United States

More information

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This

More information

Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters

Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters PPLICTION NOTE 7229 Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters uthors Jingli Hu and Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, C, US Keywords

More information

[ Care and Use Manual ]

[ Care and Use Manual ] Oasis HLB DISKS I. Introduction Oasis HLB is a Hydrophilic-Lipophilic-Balanced, water-wettable, reversed-phase sorbent for all your SPE needs. It is made from a specific ratio of two monomers, the hydrophilic

More information

EPA 815-B Revision 1.0. July 2003

EPA 815-B Revision 1.0. July 2003 METHOD 552.3 DETERMINATION OF HALOACETIC ACIDS AND DALAPON IN DRINKING WATER BY LIQUID-LIQUID MICROEXTRACTION, DERIVATIZATION, AND GAS CHROMATOGRAPHY WITH ELECTRON CAPTURE DETECTION EPA 815-B-03-002 Revision

More information

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm) columns and Trap Columns IonPac AG, AS, mm Eluent Source: EG Temperature: C IonPac AC ( mm) Flow Rate:. m/min Eluent: Potassium hydroxide, Inj. Volume: m, preconcentrated mm from to min, mm mm from min

More information

Determination of Inorganic Anions in Wastewater by Ion Chromatography

Determination of Inorganic Anions in Wastewater by Ion Chromatography Application Note 5 Determination of Inorganic Anions in Wastewater INTRODUCTION The determination of common inorganic anions in environmental waters, such as wastewater and drinking, ground, and surface

More information

The determination of trace anions in concentrated phosphoric acid

The determination of trace anions in concentrated phosphoric acid TECHNICAL NOTE The determination of trace anions in concentrated phosphoric acid Authors Edward Kaiser and Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA Keywords Ion chromatography, IC, IonPac

More information

Expanded capabilities in ammonium and amine detection

Expanded capabilities in ammonium and amine detection PRODUCT SPECIFICATIONS Thermo Scientifi c Dionex SC-CERS 500 Salt Converter-Cation Electrolytically Regenerated Suppressor Expanded capabilities in ammonium and amine detection Benefits Broadened ammonium

More information

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath APPLICATIN NTE 9 Determination of an anionic fluorochemical surfactant in a semiconductor etch bath Authors Mark Laikhtman and Jeff Rohrer Thermo Fisher Scientific, Sunnyvale, CA Keywords Ion chromatography,

More information

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency Anthony Edge, 1 Luisa Pereira, 1 Dafydd Milton 1 and Andrew Shalliker 2 1 Thermo Fisher Scientific,

More information

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry O. Scheibner, 1 P. van Baar, 2 F. Wode, 2 U. Dünnbier, 2 K. Akervik, 3 J. Humphries, 3 M. Bromirski 1

More information

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM IC Application Work AW CH6-1048-012011 Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM Branch: Chemical industry; Water, wastewater, environmental protection,

More information

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method Xiang He and Marta Kozak ThermoFisher Scientific, San Jose, CA,

More information

Sample Preparation for Ion Chromatography

Sample Preparation for Ion Chromatography Sample Preparation for Ion Chromatography Comprehensive Solutions to Sample Preparation Challenges Now sold under the Thermo Scientific brand Choose from a Broad Range of Solutions No matter what your

More information

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System G. Maio 1, F. Steiner 1, H. Franz 1, M. Tracy 2, X. Liu 2, F. Arnold 1 1 Dionex Softron GmbH, D-21 Germering,

More information

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography Carl Fisher and Linda Lopez Thermo Fisher Scientific, Sunnyvale,

More information

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis A. Caruso, M. Santoro, P. Magni, S. Pelagatti, and R. Facchetti Thermo Fisher Scientific, Milan,

More information

Determinations of Heat Stable Amine Salts and Amines in Amine Scrubbing Solutions Using Suppressed Conductivity and Charge Detection

Determinations of Heat Stable Amine Salts and Amines in Amine Scrubbing Solutions Using Suppressed Conductivity and Charge Detection Determinations of Heat Stable mine Salts and mines in mine Scrubbing Solutions Using Suppressed Conductivity and Charge Detection Terri Christison, Monika Verma, Pranathi Perati, Linda Lopez Thermo Fisher

More information

Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography

Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography APPLIATION NOTE 78 Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography Authors Soon Fatt Lee, Aaron Rose, Terri hristison, and Jeff Rohrer Thermo Fisher

More information

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany Generic Method Approach for Pharmaceutical Drug Discovery and Development using Reversed-Phase Hydrophilic Interaction Liquid Chromatography with Universal Charged Aerosol Detection Frank Steiner, Michael

More information

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20544 Key Words Hydrophilic, HILIC,

More information

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography APPLICATION NOTE 113 Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography Author Edward Kaiser Thermo Fisher Scientific, Sunnyvale, CA Keywords Trace ionic

More information

ProPac WCX-10 Columns

ProPac WCX-10 Columns ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,

More information

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep pplication Note 70 Determination of Silicate in High Purity Water Using Ion Chromatography and utoprep Introduction The water used in the manufacture of semiconductors and other modern electronic components

More information

Determination of Aniline and Nitroanilines in Environmental and Drinking Waters by On-Line SPE

Determination of Aniline and Nitroanilines in Environmental and Drinking Waters by On-Line SPE Determination of Aniline and Nitroanilines in Environmental and Drinking Waters by On-Line SPE Li Lang, Xu Qun, and Jeffrey Rohrer Thermo Fisher Scientific, Shanghai, People s Republic of China; Thermo

More information

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

Application of Eluent Generation for Trace Anion Analysis of Borated Waters Application of Eluent Generation for Trace Anion Analysis of Borated Waters Edward Kaiser and Jeff Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA Application Note 166 Introduction Boric acid is used

More information

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography Kirk Chassaniol Manager of IC Technical Sales Support Thermo Fisher Scientific 1 The world leader in serving

More information

The Determination of Trace Anions in Concentrated Phosphoric Acid

The Determination of Trace Anions in Concentrated Phosphoric Acid Technical Note The Determination of Trace Anions in Concentrated Phosphoric Acid INTRODUCTION The determination of trace anions in phosphoric acid is hampered by a large excess of phosphate ion. Chloride

More information

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Andrea Caruso and Massimo Santoro, Thermo Fisher Scientific, Milan, Italy Application Note 1316 Key

More information

Monitoring Protein PEGylation with Ion Exchange Chromatography

Monitoring Protein PEGylation with Ion Exchange Chromatography Monitoring Protein PEGylation with Ion Exchange Chromatography Peter Yu, Deanna Hurum, Jinyuan (Leo) Wang, 2 Terry Zhang, 2 and Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, CA; 2 Thermo Fisher Scientific,

More information

Determination of trace anions in concentrated glycolic acid

Determination of trace anions in concentrated glycolic acid TECHNICAL NOTE Determination of trace anions in concentrated glycolic acid Authors Edward Kaiser and Jeff Rohrer Thermo Fisher Scientific, Sunnyvale, CA Keywords Ion chromatography, IC, Dionex ICS- +,

More information

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography Application Note 9 Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography Introduction The computer, semiconductor, and food industries need analytical

More information

Determination of trace anions in high-nitrate matrices by ion chromatography

Determination of trace anions in high-nitrate matrices by ion chromatography APPLICATION NOTE 7 Determination of trace anions in high-nitrate matrices by ion chromatography Authors Edward Kaiser and Jeff Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA Keywords Contamination,

More information

High-Performance Chromatography Superior isocratic separation of

High-Performance Chromatography Superior isocratic separation of columns I o n P a c C S A C a t i o n - E x c h a n g e C o l u m n The IonPac CSA cation-exchange column provides fast analysis of mono- and divalent cations, ammonium, and aliphatic amines simultaneously

More information

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches Hydrophilic Interaction Liquid Chromatography: Method Development Approaches Monica Dolci, Luisa Pereira, and Tony Edge Thermo Fisher Scientific, Runcorn, Cheshire, UK Abstract This poster summarizes the

More information

Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography

Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography Application Update 144 Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography INTRODUCTION Hexavalent chromium, Cr(VI), is the most toxic form of the metal chromium, a primary

More information

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography Application Note 75 Determination of Sulfate and Chloride in Ethanol by Ion Chromatography Ethanol used as a blending agent in gasoline can be contaminated with chloride and sulfate that form plugging

More information

Quantitative determination of ethephon in soluble concentration (SL) by Ion chromatography

Quantitative determination of ethephon in soluble concentration (SL) by Ion chromatography Quantitative determination of ethephon in soluble concentration (SL) by Ion chromatography Author : Li Guoping Yu Rong Shui Rong Institute for the Control of Agrochemicals, Ministry of Agriculture, P.

More information