1 Keys to Implementing Mass Spectrometry in the Clinical Laboratory Paul J. Taylor Chromatography Mass Spectrometry Satellite Meeting, AACB 20th September, 2013 Dept of Clinical Pharmacology, Princess Alexandra Hospital, Brisbane, Australia
2 Presentation Basic Introduction to Instrumentation Matrix Effects Challenges
3 Section 1: Instrumentation
4 Why use HPLC-Tandem Mass Spectrometry? HPLC is a fundamental separation technique that is amenable to most pharmaceuticals and biological molecules from small molecules to peptides to proteins Samples do not require volatility or thermal stability as for GC No need for sample derivatisation
5 Why use HPLC-Tandem Mass Spectrometry? A combination of hydrophobic separation and mass selectivity Tandem mass spectrometry is more sensitive and far more specific than other HPLC detectors Can provide improved selectivity over immunoassays
6 The 3 S Advantages of Mass Spectrometry to Solve Analytical Specificity it Sensitivity Speed Problems (McLafferty FW. Science 1981;214:280-7.)
7 What is Mass Spectrometry?
8 What is Mass Spectrometry? Mass spectrometry is the production and differentiation of ions in the gas phase
9 Keys to Success Ionization Ion transmission
10 Components of a Mass Spectrometer Ionization/ desorption Mass Sorting Detection ti + Source Analyzer Ion Detection Inlet Sample Introduction Solid Liquid Vapour Mass Spectrum Data Analysis
11 Types of Ionization Atmospheric Pressure (API) Electrospray (ESI) Atmospheric Pressure Chemical Ionization (APCI) Electron Impact (EI) Chemical Ionization (CI) Fast Atom Bombardment (FAB) Matrix Assisted Laser Desorption (MALDI)
12 Electrospray Ion Source Curtain Gas Electrospray Probe Atmospheric pressure Vacuum HPLC Eluant 3-6 kv N 2 for Nebulization Charged Droplets Ions Orifice Source: PE/Sciex
13 Theory of Electrospray (Ion Evaporation) Liquid Phase Ionization Liquid 5 kv Droplet Droplet Coulomb + Formation Evaporation Explosion Ion Evaporation + CH CH 3 N CH CH 3 + Molecular Ion
14 APCI Interface Liquid from HPLC Heat M H 2 O H 2 O H O 2 M H O 3 + Molecular Ions (M+H) + Air for Nebulization Heat Vaporization Ion molecule Reactions Corona Discharge (5KV)
15 Electrospray Molecular Weigh ht APCI 10 Non-polar Polarity High Polarity
16 Magnetic Sector Time-of-flightflight Ion Trap Quadrupole Types of Analyzers All separate ions which have different charge-to- mass ratios, m/z in magnetic field or electric field
17 Mass Spectrum Flumazenil [M+H] + O N O F N O N [M+Na] + [M+K] +
18 Mass Spectrum of Haemoglobin α (15126) and β (15867) Chains
19 Chromatography
20 Chromatography To obtain maximum signal the column selected should provide adequate retention with highest possible organic solvent content t To obtain retention with polar compounds the use normal phase chromatography may be required* *Naidong W, et al. J Chromatogr B 2001;754:
21 Example Determination of Cocaine in Urine by HPLC-ESI ESI-MS/MS O Basic compound pk a = 5.6 Protonated species Mobile phase at ph 3.0 N O O O Needham SR, et al. J Chromatogr B 2000;748:
22 Example Determination of Cocaine in Urine by HPLC-ESI ESI-MS/MS What column would you start your method development with? A silica based C18 column To obtain adequate retention < 15% organic solvent composition
23 New Stationary Phase - Pentafluorophenylpropyl Bonded to Silica CH 3 F Si O Si F CH 3 F F F
24 PFPP vs C18 cetonitrile:5 il mm Ammonium Formate (ph 3.0) 4.5 fold lower LOD 90% ACN 15% ACN
25 Section 2: Matrix Effects
26 Matrix Effects A major problem when generating ions using atmospheric pressure ionization techniques Must be appreciated when developing a method
27 Matrix Effects Matrix effects are the alteration in ionization efficiency of an interface due to the presence of co- eluting ions The exact mechanism is currently unknown Co-eluting ions alter droplet formation and droplet evaporation leading to variable generation of the ions of interest in the gas phase
28 Matrix Effects Depending on the environment in which ionization and ion evaporation takes place, this competition may: 1. Decrease analyte signal ion suppression 2. Increase analyte signal ion enhancement Greatest influence on electrospray ionization
29 Matrix Effects Compound dependant A study of 4 compounds of different polarities, under the same mass spectrometric conditions: 1. Most polar largest ion suppression 2. Least polar less affected by ion suppression Bonfiglio R, et al. The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds. Rapid Commun Mass Spectrom 1999;13:
30 How to Assess Matrix Effects Post-extraction addition Post-column infusion
31 Post-Extraction Addition Supplement the compound of interest post- extraction Compare the response with a mobile phase standard
32 Post-Extraction Addition Evaluation (Buhrman et al, J Am Soc Mass Spectrom., 1996.) Method Post- extraction area Mobile phase area Hexane liq-liq Ion suppression (%) Back-extraction C18 SPE
33 Post-extraction Addition Is considered a static method that provides information about matrix effects at the point of elution of the analyte. A more dynamic method of assessing matrix effects is post-column infusion
34 Post-Column Infusion HPLC Analytical Column Mass Spectrometer Infusion Pump Flow Splitter Electrospray Interface
35 Post-Column Infusion Test Mobile Phase 2000 Intensity (cps) Time (min)
36 Protein Precipitation 2000 Inte ensity (cp ps) Time (min)
37 Solid Phase Extraction 2000 ps) Inte ensity (c Time (min)
38 Where Does it Come From? Additives in the mobile phase
39 Acetate Vs Trifluoroacetic acid for Gentamycin Analysis TFA decreases ionization efficiency Lagerwerf FM et al., TrAC 2000;19:
40 Where Does it Come From? Additives in the mobile phase Sample extract
41 Sample Extract Salts retention of compounds Phospholipids???
42 Phospholipids and Matrix Effects Monitor specific transitions In-source multiple reaction monitoring glycerophosphocholines (GPCho) major constituent of phospholipids p p in plasma (Little JL et al. J Chrom B 2006;833:219-30) 30)
43 High Cone Voltage Low Collision Energy m/z
44 Protein Precipitation
45 Where Does it Come From? Additives in the mobile phase Sample extract Previous samples or build-up up on column
46 Endogenous Ion Suppression Protein precipitation of plasma Lagerwerf FM et al., TrAC 2000;19:
47 What Can Be Done to Minimize Matrix Sample preparation Chromatography Different ion source Effects? Internal standard selection compensates
48 Matrix Effects and the Clinical Laboratory Inter-patient variability of the matrix Biological samples from a patient with renal failure, aids patient, burns patient compared to a healthy volunteer
49 Patient to Patient Variability Matuszewski BK, et al., Anal Chem 2003;75:
50 Case Study
51
52 Methods Development for Electrospray Chromatography (k ) differences 50:50 ACN:buffer vs 90:10 ACN:buffer Extraction differences Ether extraction (non-buffered) vs Ether extraction (buffered to ph 9.8)
53 Extraction vs Chromatography Non-selective extraction Selective extraction Plasma # Little separation k =1.75 Good separation k =13.25 Little separation k =1.75 Good separation k = Matuszewski BK, et al. Anal Chem 1998;70:882-9.
54 Extraction vs Chromatography Non-selective extraction Selective extraction Plasma # Little separation k =1.75 Good separation k =13.25 Little separation k =1.75 Good separation k = Matuszewski BK, et al. Anal Chem 1998;70:882-9.
55 Extraction vs Chromatography Non-selective extraction Selective extraction Plasma # Little separation k =1.75 Good separation k =13.25 Little separation k =1.75 Good separation k = Matuszewski BK, et al. Anal Chem 1998;70:882-9.
56 Extraction vs Chromatography Non-selective extraction Selective extraction Plasma # Little separation k =1.75 Good separation k =13.25 Little separation k =1.75 Good separation k = Matuszewski BK, et al. Anal Chem 1998;70:882-9.
57 Comments A combination of effective sample preparation and chromatography is required for successful a quantification method using HPLC-MS
58 Further Reading Annesley TM. Clin Chem 2003;49:1041. Matuszewski BK, et al. Anal Chem 1998;70:822. Matuszewski BK, et al. Anal Chem 2003;75:3019. Taylor PJ. Clin Biochem 2005;38:328. Mallet CR, et al. 2004;18:49. Rogatsky E, et al. 2005;16:1757.
59 Section 3: Challenges
60 Economic Barrier There is a perceived cost barrier A triple quadrupole instrument requires an initial capital investment of greater than $US This compares poorly with immunoassays that are supplied by the manufacturer on a reagent- rental basis
61 Economic Barrier Redundancy d means at least 2 instruments t are required Although the long-term cost per assay may be higher for the immunoassay, it is the lump sum investment for the mass spectrometer that prevents many laboratories from entry into this technology
62 Cost Comparison of Tacrolimus Measurement (Prof M Oellerich, Germany) LC-MS/MS MEIA Number of samples Direct costs ( ) Technician time ( ) Total costs ( ) n=3 n=15 n=3 n=
63 Personnel There is limited availability of suitable trained staff to run and trouble-shoot this equipment Clinical Scientist Mass spectrometrist This point may not be as important t as technology improvements in instrumentation occur
64 To Provide a Viable Alternative ti to Immunoassays
65 Selectivity Automation Accuracy Ease of Use Sensitivity Throughputh
66 Selectivity and Accuracy HPLC-MS has excellent selectivity and accuracy compared with immunoassays that are prone to non-specific anti-body cross-reactivityreactivity
67 Selectivity Automation Accuracy Ease of Use Sensitivity Throughputh
68 Sensitivity and Throughput Differ depending on the analyte under investigation
69 Selectivity Automation Accuracy Ease of Use 1/2 1/2 Sensitivity Throughputh
70 Ease of Use and Automation Immunoassays are superior to HPLC-MS
71 Selectivity X Automation Accuracy 1/2 1/2 Ease of Use Sensitivity Throughputh X
72 Discussion (1) For HPLC-MS technology to compete directly with immunoassays an acceptable increase in sensitivity and throughput are necessary This imbalance may change as demand for this type of instrumentation grows and manufacturers improve systems
73 Discussion (2) HPLC-MS requires significant improvement in ease of use and automation Approaches such as two-dimensional chromatography minimise sample handling and preparation provide some automation
74 Discussion (3) What is required Walk-up instrument 1. Sample is placed directly into the instrumentation 2. The assay requested 3. Sample analyzed 4. Result is reported in a suitable format for clinical interpretation
75 Availability of suitable internal standards
76 Internal Standards Compensate for changes in ionisation efficiency Simultaneous methods may require multiple internal standards depending on the chemical differences of the analytes Stokvis Eetal al. Rapid Commun Mass Spectrom 2005; 19:
77 Isotope Labeled Internal Standards Provide the highest order of reliability Incomplete recovery does not effect results Co-elution any variation in ion formation should alter equally for analyte and IS Matrix effects do not influence IS/analyte ratio
78 Isotope Labeled Internal Standards Labelled internal standards can be expensive and not always available Labelled internal standards must be used for methods in the clinical setting
79 Harmonization
80 Harmonization With the development of slightly different variations of a particular test used by various laboratories there is a greater likelihood of different results Thus harmonization of mass spectrometric methods is required to establish normal ranges, decision points, etc.
81 Discussion HPLC-MS is an important technology that is and will complement and extend the capabilities of the clinical i l laboratory HPLC-MS clearly offers much more versatility and scope than GC-MS and provides improved selectivity over immunoassays
82 Keys to Success Ionization Ion transmission
83 Discussion Matrix effects must be understood and carefully evaluated There are some challenges that need to be resolved This is due in part to mass spectrometry not being a turn-key solution to an analytical problem
84 Final Thoughts Dr Michael Kinter stated in a 1995 review: The expectation of mass spectrometry is limited to developing non-routine information about specialized analytes Anal Chem 1995;67 67: R-7R.
85 Final Thoughts Mass spectrometry is widely appreciated as a powerful analytical method, that can be used for both the qualitative ti and quantitative analysis of nearly all types of molecules. In light of this power, I would propose that mass spectrometry is ready for a substantially larger role in routine clinical analysis.
86 Final Thoughts Mass spectrometry is widely appreciated as a powerful analytical method, that can be used for both the qualitative and quantitative analysis of nearly all types of molecules. In light of this power, I would propose p that mass spectrometry is ready for a substantially larger role in routine clinical analysis. Kinter M. Clin Chem 2004;50:
TANDEM MASS SPECTROSCOPY
TANDEM MASS SPECTROSCOPY 1 MASS SPECTROMETER TYPES OF MASS SPECTROMETER PRINCIPLE TANDEM MASS SPECTROMETER INSTRUMENTATION QUADRAPOLE MASS ANALYZER TRIPLE QUADRAPOLE MASS ANALYZER TIME OF FLIGHT MASS ANALYSER
More informationChemistry Instrumental Analysis Lecture 37. Chem 4631
Chemistry 4631 Instrumental Analysis Lecture 37 Most analytes separated by HPLC are thermally stable and non-volatile (liquids) (unlike in GC) so not ionized easily by EI or CI techniques. MS must be at
More informationLC-MS/MS in the Clinical Laboratory. Jo Adaway
LC-MS/MS in the Clinical Laboratory Jo Adaway LC-MS/MS in the clinical laboratory LC-MS/MS is mainly used for quantification of analytes used in the diagnosis and monitoring of disease Semi-quantitative
More informationLC-MS Based Metabolomics
LC-MS Based Metabolomics Analysing the METABOLOME 1. Metabolite Extraction 2. Metabolite detection (with or without separation) 3. Data analysis Metabolite Detection GC-MS: Naturally volatile or made volatile
More informationM M e M M H M M H. Ion Sources
Ion Sources Overview of Various Ion Sources After introducing samples into a mass spectrometer, the next important step is the conversion of neutral molecules or compounds to gas phase ions. The ions could
More informationMolecular Mass Spectrometry
Molecular Mass Spectrometry Mass Spectrometry: capable of providing information about (1) Elemental composition of samples of matter: atomic mass (2) Structures of inorganic, organic, and biological molecules
More informationSelecting an LC/MS Interface Becky Wittrig, Ph.D.
Selecting an LC/MS Interface Becky Wittrig, Ph.D. RESTEK CORPORATION LC/MS Interfaces I. Background of LC/MS I. Historical Perspective II. Reasons for use II. Interfaces I. Transport devices II. Particle
More informationMass Spectrometry (MS)
Mass Spectrometry (MS) Alternative names: Mass spectrometric (selective) detector (MSD) Spectrometry - methods based on interaction of matter and radiation Mass spectrometry - method based on formation
More informationQuantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.
Quantitative analysis of small molecules in biological samples 100 Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB % 0 300 500 700 900 1100 1300 1500 1700 m/z Class Overview Introduction
More informationFundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics
Mass spectrometry (MS) is the technique for protein identification and analysis by production of charged molecular species in vacuum, and their separation by magnetic and electric fields based on mass
More informationLIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC
LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC INTRODUCTION Principle: LC/MS is a technique that combines physical separation capabilities of liquid
More informationMass Spectrometry. Electron Ionization and Chemical Ionization
Mass Spectrometry Electron Ionization and Chemical Ionization Mass Spectrometer All Instruments Have: 1. Sample Inlet 2. Ion Source 3. Mass Analyzer 4. Detector 5. Data System http://www.asms.org Ionization
More informationfor the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York
Mass Spectrometry for the Novice John Greaves and John Roboz (^>, yc**' CRC Press J Taylor & Francis Group Boca Raton London New York CRC Press is an imprint of the Taylor & Francis Croup, an informa business
More informationMass Spectrometry. A truly interdisciplinary and versatile analytical method
Mass Spectrometry A truly interdisciplinary and versatile analytical method MS is used for the characterization of molecules ranging from small inorganic and organic molecules to polymers and proteins.
More informationProudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Applied Biosystems QStar Pulsar i Features of the API QSTAR Pulsar i The
More informationLecture 15: Introduction to mass spectrometry-i
Lecture 15: Introduction to mass spectrometry-i Mass spectrometry (MS) is an analytical technique that measures the mass/charge ratio of charged particles in vacuum. Mass spectrometry can determine masse/charge
More informationIntroduction. Chapter 1. Learning Objectives
Chapter 1 Introduction Learning Objectives To understand the need to interface liquid chromatography and mass spectrometry. To understand the requirements of an interface between liquid chromatography
More informationMass Spectrometry. General Principles
General Principles Mass Spectrometer: Converts molecules to ions Separates ions (usually positively charged) on the basis of their mass/charge (m/z) ratio Quantifies how many units of each ion are formed
More informationHPLC solvents and mobile phase additives
HPLC solvents and mobile phase additives The following is intended to be a guide for the choice of solvent and mobile phase additives. Of course the choice of solvents for LC will be dictated primarily
More information1) In what pressure range are mass spectrometers normally operated?
Exercises Ionization 1) In what pressure range are mass spectrometers normally operated? Mass spectrometers are usually operated in the high vacuum regime to ensure mean free paths significantly longer
More informationIonization Methods in Mass Spectrometry at the SCS Mass Spectrometry Laboratory
Ionization Methods in Mass Spectrometry at the SCS Mass Spectrometry Laboratory Steven L. Mullen, Ph.D. Associate Director SCS Mass Spectrometry Laboratory Contact Information 31 oyes Laboratory (8:00-5:00
More informationChemistry 311: Topic 3 - Mass Spectrometry
Mass Spectroscopy: A technique used to measure the mass-to-charge ratio of molecules and atoms. Often characteristic ions produced by an induced unimolecular dissociation of a molecule are measured. These
More informationMass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS
Mass Spectrometry Hyphenated Techniques GC-MS LC-MS and MS-MS Reasons for Using Chromatography with MS Mixture analysis by MS alone is difficult Fragmentation from ionization (EI or CI) Fragments from
More informationAnalysis of Polar Metabolites using Mass Spectrometry
Analysis of Polar Metabolites using Mass Spectrometry TransMed Course: Basics in Clinical Proteomics and Metabolomics. Oct 10-19, 2012 dd.mm.yyyy Vidya Velagapudi, Ph.D, Adjunct Professor Head of the Metabolomics
More informationInstrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai
303351 Instrumental Analysis Mass Spectrometry Lecturer:! Somsak Sirichai Mass Spectrometry What is Mass spectrometry (MS)? An analytic method that employs ionization and mass analysis of compounds in
More informationAnalytical Technologies and Compound Identification. Daniel L. Norwood, MSPH, PhD SCĪO Analytical Consulting, LLC.
Analytical Technologies and Compound Identification Daniel L. Norwood, MSPH, PhD SCĪ Analytical Consulting, LLC. Extractables/Leachables Characterization (USP) Characterization is the discovery,
More informationLecture 8: Mass Spectrometry
intensity Lecture 8: Mass Spectrometry Relative abundance m/z 1 Ethylbenzene CH 2 CH 3 + m/z = 106 CH 2 + m/z = 91 C 8 H 10 MW = 106 CH + m/z = 77 + 2 2 What information can be obtained from a MS spectrum?
More informationIntroduction to LC-MS
Wednesday April 5, 2017 10am Introduction to LC-MS Amy Patton, MS Laboratory Manager, Pinpoint Testing, LLC Little Rock, AR DESCRIPTION: Amy Patton, laboratory manager for Pinpoint Testing, will begin
More informationMolecular Mass Spectrometry
Molecular Mass Spectrometry Mass Spectrometry: capable of providing information about (1) Elemental composition of samples of matter: atomic mass (2) Structures of inorganic, organic, and biological molecules
More informationLecture 8: Mass Spectrometry
intensity Lecture 8: Mass Spectrometry Relative abundance m/z 1 Ethylbenzene experiment CH 2 CH 3 + m/z = 106 CH 2 + m/z = 91 C 8 H 10 MW = 106 CH + m/z = 77 + 2 2 What information can we get from MS spectrum?
More informationMass Spectrometry for Chemists and Biochemists
Erasmus Intensive Program SYNAPS Univ. of Crete - Summer 2007 Mass Spectrometry for Chemists and Biochemists Spiros A. Pergantis Assistant Professor of Analytical Chemistry Department of Chemistry University
More informationABI 3200 Q TRAP LC/MS/MS System
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL 001.847.913.0777 ABI 3200 Q TRAP LC/MS/MS System The advantages of an ion trap and the performance of a triple quad. All in one system.
More informationMass spectrometry gas phase transfer and instrumentation
Objectives of the Lecture spectrometry gas phase transfer and instrumentation Matt Renfrow January 15, 2014 1. Make ions 2. Separate/Analyze 3. Detect ions 4. What is mass resolution and mass accuracy?
More informationTranslational Biomarker Core
Translational Biomarker Core Instrumentation Thermo Scientific TSQ Quantum Triple Quadrupole Mass Spectrometers. There are two TSQ Quantum Ultra AM instruments available in the TBC. The TSQ Quantum Ultra
More informationMass Spectrometry in MCAL
Mass Spectrometry in MCAL Two systems: GC-MS, LC-MS GC seperates small, volatile, non-polar material MS is detection devise (Agilent 320-MS TQ Mass Spectrometer) Full scan monitoring SIM single ion monitoring
More informationPRINCIPLES AND PRACTICE OF BIOANALYSIS
PRINCIPLES AND PRACTICE OF BIOANALYSIS Richard F. Venn Pfizer Central Research, Sandwich, UK London and New York List of contributors Preface xvi xvii 1 Physico-chemical properties of drugs and metabolites
More informationAssay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer
38 Current Trends in Mass Spectrometry November 6 Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer This article demonstrates the improved
More informationMS Goals and Applications. MS Goals and Applications
MS Goals and Applications 3 Several variations on a theme, three common steps Form gas-phase ions choice of ionization method depends on sample identity and information required Separate ions on basis
More information20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n
20.2 Ion Sources electron ionization produces an M + ion and extensive fragmentation chemical ionization produces an M +, MH +, M +, or M - ion with minimal fragmentation MALDI uses laser ablation to transfer
More informationElectrospray Ion Trap Mass Spectrometry. Introduction
Electrospray Ion Source Electrospray Ion Trap Mass Spectrometry Introduction The key to using MS for solutions is the ability to transfer your analytes into the vacuum of the mass spectrometer as ionic
More informationPlasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method
Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method Xiang He and Marta Kozak ThermoFisher Scientific, San Jose, CA,
More informationMass spectrometry and elemental analysis
Mass spectrometry and elemental analysis A schematic representation of a single-focusing mass spectrometer with an electron-impact (EI) ionization source. M: + e _ M +. + 2e _ Ionization and fragmentation
More informationInvestigation of retention mechanisms in HILIC chromatography: Important considerations for robust method development
Investigation of retention mechanisms in HILIC chromatography: Important considerations for robust method development Anders Fridström Sigma- Aldrich GMBH Abstract Investigation of Retention Mechanisms
More informationChoosing the metabolomics platform
GBS 748 Choosing the metabolomics platform Stephen Barnes, PhD 4 7117; sbarnes@uab.edu So, I have my samples what s next? You ve collected your samples and you may have extracted them Protein precipitation
More informationLC-MS/MS Method for the Determination of Diclofenac in Human Plasma
LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core
More informationStudy of Non-Covalent Complexes by ESI-MS. By Quinn Tays
Study of Non-Covalent Complexes by ESI-MS By Quinn Tays History Overview Background Electrospray Ionization How it is used in study of noncovalent interactions Uses of the Technique Types of molecules
More informationChemical Aspects of Mass Spectrometry
Chemical Aspects of Mass Spectrometry Abraham Badu Chemistry and Biochemistry, OSU July 12, 217 Spread of MS by Discipline https://masspec.scripps.edu/ mass spectrometry 2 1 Current Challenges in Mass
More informationCh 13. Basics of Mass Spectrometry (I) : Principles & Ionization Sources
Ch 13. Basics of Mass Spectrometry (I) : Principles & Ionization Sources Why should you be interested in mass spectrometry (MS)? - to identify unknown compounds - to quantify known materials - to elucidate
More informationHplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation
Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved We have made it easy for you to find a PDF Ebooks without any digging. And by having access
More informationChemistry Instrumental Analysis Lecture 34. Chem 4631
Chemistry 4631 Instrumental Analysis Lecture 34 From molecular to elemental analysis there are three major techniques used for elemental analysis: Optical spectrometry Mass spectrometry X-ray spectrometry
More informationCHROMATOGRAPHY AND MASS SPECTROMETER
22 CHROMATOGRAPHY AND MASS SPECTROMETER 22.1 INTRODUCTION We know that the biochemistry or biological chemistry deals with the study of molecules present in organisms. These molecules are called as biomolecules
More informationContact Information. Speaker Financial Disclosure Information. Fitting Linear Quadrupoles and Round Flight Tubes into the Square Clinical Laboratory
Fitting Linear Quadrupoles and Round Flight Tubes into the Square Clinical Laboratory The What, Where and Why of Clinical Mass Spectrometry Frederick G. Strathmann 2014 Institute for Learning Quarterly
More informationIntroduction to Pharmaceutical Chemical Analysis
Introduction to Pharmaceutical Chemical Analysis Hansen, Steen ISBN-13: 9780470661222 Table of Contents Preface xv 1 Introduction to Pharmaceutical Analysis 1 1.1 Applications and Definitions 1 1.2 The
More informationSelecting Detectors for Compounds with No Optical Absorbance
C146-E114 Selecting Detectors for Compounds with No Optical Absorbance Technical Report vol.15 1. Features of Absorbance Detectors In HPLC, the detector is selected in accordance with the analyte. Many
More informationHigh-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes
High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes Joe DiBussolo, Marta Kozak Thermo Fisher Scientific, San Jose, CA Application
More informationTR ACE ORGANIC. lgcstandards.com/foodandenvironment
U S E O F S TA B L E I S OTO P E I NTE R N A L S TA N D A R D S F O R TR ACE ORGANIC A N A LY S I S lgcstandards.com/foodandenvironment dr.ehrenstorfer@lgcgroup.com This paper explains why stable isotope
More informationQualitative Organic Analysis CH 351 Mass Spectrometry
Qualitative Organic Analysis CH 351 Mass Spectrometry Bela Torok Department of Chemistry University of Massachusetts Boston Boston, MA General Aspects Theoretical basis of mass spectrometry Basic Instrumentation
More informationHplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation
Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved We have made it easy for you to find a PDF Ebooks without any digging. And by having access
More informationCHAPTER 1 Role of Bioanalytical Methods in Drug Discovery and Development
UMMERY The need to develop new analytical methods for assurance of quality, safety and efficacy of drugs and pharmaceuticals is quite important because of their use not only as health care products but
More informationQuantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry
Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry Shijun Lua, Buu N. Trana, Jamie L. Nelsenb, Kenneth M. Aldousa. Journal of Chromatography
More informationMS Goals and Applications. MS Goals and Applications
MS Goals and Applications 1 Several variations on a theme, three common steps Form gas-phase ions choice of ionization method depends on sample identity and information required Separate ions on basis
More informationWADA Technical Document TD2003IDCR
IDENTIFICATION CRITERIA FOR QUALITATIVE ASSAYS INCORPORATING CHROMATOGRAPHY AND MASS SPECTROMETRY The appropriate analytical characteristics must be documented for a particular assay. The Laboratory must
More informationUtilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification
Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography Tips and Techniques to Optimize ELSD and MS based Purification Utilizing ELSD and MS as Secondary Detectors for Prep
More informationFinnigan LCQ Advantage MAX
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Finnigan LCQ Advantage MAX The Finnigan LCQ Advantage MAX ion trap mass spectrometer
More informationThis document is a preview generated by EVS
TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 15641 August 2007 ICS 67.050 English Version Food analysis - Determination of pesticide residues by LC- MS/MS - Tandem mass spectrometric parameters
More informationMS731M: Chemical Analysis of Materials
(Revised) Course Code and Title Course Coordinator Details of Course MS731M: Chemical Analysis of Materials Dr. Eileen Fong (Course Coordinator) Dr. Thresen Matthew Rationale for introducing this course
More informationLive Webinar : How to be more Successful with your ACQUITY QDa Detector?
Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Q&A Transcript ---------------- Q - How do you generate multiple charges reproductively? A - If you use the same settings on the
More informationMixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma
Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma Ken Meadows, Thermo Fisher Scientific, Runcorn, UK Application Note 20789 Key Words
More informationMatrix effects: The Achilles heel of quantitative high-performance liquid chromatography electrospray tandem mass spectrometry
Clinical Biochemistry 38 (2005) 328 334 Review Matrix effects: The Achilles heel of quantitative high-performance liquid chromatography electrospray tandem mass spectrometry Paul J. Taylor* Department
More information(Refer Slide Time 00:09) (Refer Slide Time 00:13)
(Refer Slide Time 00:09) Mass Spectrometry Based Proteomics Professor Sanjeeva Srivastava Department of Biosciences and Bioengineering Indian Institute of Technology, Bombay Mod 02 Lecture Number 09 (Refer
More informationIDENTIFICATION OF ORGANOMETALLIC COMPOUNDS USING FIELD DESORPTION IONIZATION ON THE GCT
IDETIFICATIO OF ORGAOMETALLIC COMPOUDS USIG FIELD DESORPTIO IOIZATIO O THE GCT David Douce 1, Michael Jackson 1, Robert Lewis 1, Peter Hancock 1, Martin Green 1 and Stuart Warriner 2 1 Waters Corporation,
More informationLC MS analysis of metabolites. Basis of Chromatography
GBS 724 LC MS analysis of metabolites Stephen Barnes, PhD 4 7117; sbarnes@uab.edu Basis of Chromatography A moving (mobile) phase passes over an inert, stationary phase The compounds differentially interact
More informationOther Methods for Generating Ions 1. MALDI matrix assisted laser desorption ionization MS 2. Spray ionization techniques 3. Fast atom bombardment 4.
Other Methods for Generating Ions 1. MALDI matrix assisted laser desorption ionization MS 2. Spray ionization techniques 3. Fast atom bombardment 4. Field Desorption 5. MS MS techniques Matrix assisted
More informationMass Spectrometry. Quantitative Mass Spectrometry Chiral Mass Spectrometry
Mass Spectrometry Quantitative Mass Spectrometry Chiral Mass Spectrometry Quantitation by MS Goal is to develop methodology to sensitively, specifically, accurately and rapidly measure one or more compounds
More informationLiquid Chromatography in conjunction with Mass Spectrometry (LC-MS)
Review Article Liquid Chromatography in conjunction with Mass Spectrometry (LC-MS) Shelke PG*, Tripathi AS, Dewani AP, Bakal RL, Mohale DS and Chandewar AV P. Wadhwani College of Pharmacy, Yavatmal, Maharashtra,
More informationAuxiliary Techniques Soft ionization methods
Auxiliary Techniques The limitations of the structural information in the normal mass spectrum can be partly offset by special mass-spectral techniques. Although a complete description of these is beyond
More informationTITLE: Estimation of Drugs in Biological Fluids by Liquid Chromatography Tandem Mass Spectrometry 1.1 THE OUTLOOK 02 1.
Introduction CHAPTER - 1 INTRODUCTION TITLE: Estimation of Drugs in Biological Fluids by Liquid Chromatography Tandem Mass Spectrometry CONTENTS 1.1 THE OUTLOOK 02 1.2 THE ENDEVOUR 05 1.3 SCENERY FOR THE
More informationWebinar: How to be More Successful with your ACQUITY QDa Detector Eric van Beelen
Webinar: How to be More Successful with your ACQUITY QDa Detector Eric van Beelen 2015 Waters Corporation 1 We are here to address any Questions you may have That s the benefit of participating to the
More informationApplication Note. Edgar Naegele. Abstract
Agilent MassHunter Fast computer aided analysis of LC/ESI-TF data from complex natural product extracts Part 1: Analysis of Agilent 6210 TF data with the Molecular Feature Extractor in MassHunter Workstation
More information1. The range of frequencies that a measurement is sensitive to is called the frequency
CHEM 3 Name Exam 1 Fall 014 Complete these problems on separate paper and staple it to this sheet when you are finished. Please initial each sheet as well. Clearly mark your answers. YOU MUST SHOW YOUR
More informationUltrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System
Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System Application Note Authors Mohamed Youssef and Vaughn P. Miller Agilent
More informationChapter content. Reference
Chapter 7 HPLC Instrumental Analysis Rezaul Karim Environmental Science and Technology Jessore University of Science and Technology Chapter content Liquid Chromatography (LC); Scope; Principles Instrumentation;
More informationChapter No. 1 INTRODUCTION
Chapter No. 1 INTRODUCTION The Outlook The importance of bio-analysis is most appreciated in various fields of pharmaceutical sciences. During the development of new drugs, extensive studies are performed
More informationPlasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS
Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 129 Infi nity LC, and 646 Triple Quadrupole LC/MS Application Note Clinical Research Authors Linda Côté and Christophe
More information770-9P. Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase
77-9P Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase J.T. Lee 1 Maria Esther Rodriguez Rosas 2 and Thomas E.
More informationMass Spectrometry Course
Mass Spectrometry Course Árpád Somogyi Mass Spectrometry Laboratory, Department of Chemistry and Biochemistry University of Arizona, Tucson, AZ Eötvös University, Budapest April 11-20, 2012 1 2 UA Chemistry
More informationFast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma
Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma Jon Bardsley 1, James Goldberg 2 1 Thermo Fisher Scientific, Runcorn, UK; 2 Thermo Fisher Scientific, West Palm Beach,
More informationIntroduction to Mass Spectrometry
Introduction to Mass Spectrometry Table of Contents What is mass spectrometry? Where can mass spectrometry be used? How did mass spectrometry originate? A history of mass spectrometry What is a mass spectrometer?
More informationAB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences
AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching s by Removal of Isobaric Interferences Differential Mobility Used as a Tool to Address Selectivity Challenges Adrian M. Taylor
More informationComputational Methods for Mass Spectrometry Proteomics
Computational Methods for Mass Spectrometry Proteomics Eidhammer, Ingvar ISBN-13: 9780470512975 Table of Contents Preface. Acknowledgements. 1 Protein, Proteome, and Proteomics. 1.1 Primary goals for studying
More informationYun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION
Quantitation by High Resolution Mass Spectrometry: Using Target Enhancement and Tof-MRM to Achieve Femtogram-level On-column Sensitivity for Quantitation of Drugs in Human Plasma Yun W. Alelyunas, Mark
More informationIntroduction to GC/MS
Why Mass Spectrometry? Introduction to GC/MS A powerful analytical technique used to: 1.Identify unknown compounds 2. Quantify known materials down to trace levels 3. Elucidate the structure of molecules
More informationAnalytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS
Application Note Clinical Research Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Authors Yanan Yang 1, Victor Mandragon 2, and Peter Stone 1 1
More informationQuantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS
Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1
More informationIntroduction to the Q Trap LC/MS/MS System
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment ABI Q Trap LC/MS/MS Introduction to the Q Trap LC/MS/MS System The Q Trap
More informationMass spectrometry.
Mass spectrometry Mass spectrometry provides qualitative and quantitative information about the atomic and molecular composition of inorganic and organic materials. The mass spectrometer produces charged
More informationA Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies
A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies APPLICATION BENEFITS Regulatory guidelines and recommendations place a greater emphasis on the detection
More informationOVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA
Use of High Speed/High Resolution Size-Based Chromatographic Separation of Surfactants and Oligomeric Materials with Single Quadrupole Mass Spectrometry Michael O Leary, Jennifer Gough, Tanya Tollifson
More informationMass spectrometry of proteins, peptides and other analytes: principles and principal methods. Matt Renfrow January 11, 2008
Mass spectrometry of proteins, peptides and other analytes: principles and principal methods Matt Renfrow January 11, 2008 Objectives of the Lecture 1. Make ions 2. Separate/Analyze/Detect ions 3. What
More informationBIOINF 4399B Computational Proteomics and Metabolomics
BIOINF 4399B Computational Proteomics and Metabolomics Sven Nahnsen WS 13/14 3. Chromatography and mass spectrometry Overview Recall last lecture Basics of liquid chromatography Algorithms to predict and
More information