1 Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Applied Biosystems QStar Pulsar i Features of the API QSTAR Pulsar i The API QSTAR Pulsar i Hybrid LC/MS/MS Quadrupole TOF system delivers sensitivity, selectivity, and reproducibility while providing unrivaled performance for the following applications: Characterization of proteins and peptides in the life sciences. Analysis of drug metabolite information from small quantities of metabolites. Identification of products, by-products, and contaminants in combinatorial chemistry. Features of the API QSTAR Pulsar i mass spectrometer include: Curtain gas technology prevents any impurities from getting between the analyzer and your sample, ensuring minimal operator intervention. New ion optics routinely ensure the lowest limits of detection in all biological matrices. Trouble-free, continuous operation with no daily cleaning or calibration required to maintain performance. omaldi can be adapted for high-throughput and auto-sampling. Rugged ionization sources allow for maximum performance across the widest range of flow rates and mobile phase composition. Precision-machined, gold-plated ceramic quadrupole rods with low thermal expansion coefficient. Single-phase power and air-cooled ceramic bearing turbo pumps reduce operating costs year after year. Accommodation of multiple sources including the orthogonal Matrix Assisted Laser Desorption Ionization (MALDI) source which is easily installed by removing the interface. (For more information, see MALDI Source on page 15.) Mass Spectrometry Techniques The API QSTAR Pulsar i mass spectrometer is a versatile and reliable system for performing liquid chromatography mass spectrometry (LC/MS) analysis on liquid sample streams to identify, quantify, and examine polar compounds. API QSTAR Pulsar i uses the following mass spectrometry techniques to analyze samples: Two modes of single mass spectrometry (MS): Quadrupole-based single mass spectrometry (for Q1 calibration only) Time of flight-based single mass spectrometry Two modes of tandem mass spectrometry (MS/MS):

2 Product ion mass spectrometry Precursor ion mass spectrometry Single Mass Spectrometry (MS) Single mass spectrometry (MS) is used to analyze charged molecules in order to determine the molecular weight and amount of detected ions. Individual ions detected by MS can indicate the presence of a target analyte. Quadrupole-Based Single Mass Spectrometry (Calibration Only) In a quadrupole-based single mass spectrometry (Q1 MS) scan, API QSTAR Pulsar i functions as a traditional quadrupole mass spectrometer. In this mode, API QSTAR Pulsar i generates single mass spectrometric information using the first quadrupole (Q1) section of the instrument. Time of Flight-Based Single Mass Spectrometry In a time of flight-based single mass spectrometry (TOF MS) scan, API QSTAR Pulsar i generates mass spectrometric information by pulsing ions into a flight tube and recording their precise arrival time at the detector. Ions with a greater mass-to-charge ratio take longer to travel the flight tube. Tandem Mass Spectrometry (MS/MS) The technique of MS/MS is well suited to mixture analysis because the characteristic product ion spectra can be obtained for each component in a mixture without interference from the other components, assuming that the product ions have a unique m/z ratio. You can use MS/MS for targeted analysis by monitoring specific precursor/ product ions while the sample is eluting. This type of analysis is more specific than single MS, which only discriminates on the basis of the mass-to-charge ratio. Product Ion Mass Spectrometry In a product ion scan, Q1 selects a precursor ion which fragments in Q2 (a collision cell), generating product ions which are detected in the time of flight section. Product ions can provide information on the molecular structure of the original (precursor) ions. Precursor Ion Mass Spectrometry In a precursor ion scan, API QSTAR Pulsar i detects precursor ions which generate a specific product ion. The instrument uses Q1 in mass resolving mode to scan over the mass range of interest, while the TOF section records product ion spectra for each precursor ion. The Q1 mass spectrum shows all precursor ions which produce the product ion of interest. Hardware Overview The API QSTAR Pulsar i mass spectrometer is a complex instrument with many different systems all working together to analyze the composition of your samples. This chapter includes information on the various systems inside API QSTAR Pulsar i. Sample Introduction System Vacuum System Ion Path Chamber

3 Sample Introduction System The sample introduction system manages the introduction of a sample into the API QSTAR Pulsar i instrument and the conversion of the sample into ions which you can analyze in the quadrupole and time of flight (TOF) sections of the instrument. The sample introduction system uses three methods of sample ionization: Atmospheric Pressure Chemical Ionization (APCI), IonSpray, and Matrix Assisted Laser Desorption Ionization (MALDI). The API QSTAR Pulsar i sample introduction system offers the following choice of components: LC Pump or Integrated Syringe Pump (standard) IonSpray Sources (optional) omaldi Source (optional) Ion Source Interlocks Vacuum Interface LC Pump or Integrated Syringe Pump The liquid sample stream is pumped to the ion source by a liquid chromatography (LC) pump or a syringe pump, with flow rates determined by the inlet requirements or dictated by the chromatography or by the volume of sample available. If introduced by an LC pump, the sample may be injected through a loop injector with a separation column (LC) or without (flow injection analysis or FIA). It is important that you apply the appropriate analytical procedures and practices to minimize dead volumes. Proper procedures help ensure chromatographic integrity and analytical reproducibility. It is also important that samples are sufficiently pre-filtered so that the capillary tubing in the inlets is not blocked by particles or precipitated samples or salts. IonSpray Sources The IonSpray sources generate gas phase ions which are representative of the molecular composition of the sample with minimal fragmentation. The ionspray sources include the following benefits: Allows direct observation of the inlet through plexiglass windows. Provides convenient access to the vacuum interface (quickly and easily removed without tools). Includes the following external connections: High voltage connection Gas 1 and Gas 2 connections Collision (CAD) gas connection LC inlet and splitter outlet connection Samples are normally introduced to the API QSTAR Pulsar i instrument in a flowing liquid stream when using LC sources. All five LC ion sources operate at atmospheric pressure to produce gas phase ions. These gas phase ions are subjected to mass spectrometric analysis by the instrument. The API QSTAR Pulsar i instrument uses the following LC ion sources:

4 IonSpray converts liquid phase ions into gas phase ions Samples which are introduced through the IonSpray probe are nebulized by a jet of gas and sprayed through a high-voltage sprayer, creating a mist of small highly-charged droplets. The ions in the droplets evaporate from the droplet surface in the ion source by a process termed ion evaporation. TurboIonSpray variant of the IonSpray source The TurboIonSpray uses an IonSpray inlet with an additional probe blowing hot (for example, 400 C) dry gas orthogonally to the plume of charged droplets from the sprayer. The heated gas increases the efficiency of the ion evaporation resulting in increased sensitivity (i.e., produces higher ion intensities) and the ability to handle higher liquid sample flow rates. MicroIonSpray ions in solution are emitted into the gas phase without the application of heat MicroIonSpray (µionspray) extends the capabilities of the conventional IonSpray source by greatly reducing the sample introduction flow rates, thus providing long analysis times for very small sample volumes. MicroIonSpray is based on NanoSpray technology developed by Mann and Wilm at the EMBL in Germany, but the process does not require special conductive coatings. Heated Nebulizer produces ions by nebulizing the liquid sample in a heated tube which causes the finely dispersed sample drops to vaporize. This process leaves the molecular constituents of the sample intact. These molecules are ionized via the process of Atmospheric Pressure Chemical Ionization (APCI), induced by a corona discharge needle, as they pass through the ion source chamber into the interface region. NanoSpray allows extremely low flow rates (20-40 nl/min) and efficient sample utilization. For more information about NanoSpray contact Protana ( omaldi Source The API QSTAR Pulsar i will accommodate an orthogonal Matrix Assisted Laser Desorption Ionization (omaldi) source. When the API QSTAR Pulsar i is being used for omaldi applications, the interface is removed, giving direct access to the quadrupoles to introduce the sample. To ensure better fragmentation, the recommended CAD gas for use with omaldi sources is argon; for other ion sources, nitrogen is used. CAD gas is introduced in the API QSTAR Pulsar i using a separate connection so that the change in gas types can be made. When performing omaldi applications: Both sample and matrix are placed on a target surface. Matrix compound absorbs the laser light from a pulsed laser. Matrix in turn desorbs and ionizes the sample. Ions move down the quadrupoles and are orthogonally injected into the Time of Flight (TOF) chamber and are recorded. omaldi plates can hold multiple samples, with the position of the plate adjusted to let the stationary laser strike each sample as desired. omaldi analysis is generally quick and can be automated. While the omaldi source is in use, unused inter-connections are

5 safely located on a blanking panel located on the frame inside the instrument. Traditional MALDI uses post-source decay to fragment ions for detection in the TOF section. With the API QSTAR Pulsar i, you control fragmentation and improve results by filtering and fragmenting the ions in the quadrupoles. Variety in thickness of the sample deposit on the plate does not affect mass accuracy in the TOF. Ion Source Interlocks The purpose of the ion source interlocks is to disable high voltages in the sample introduction system. WARNING! Do not rely solely on the interlocks to ensure safety from the instrument s high voltage. When performing routine maintenance, turn off the main circuit breaker and disconnect the main power supply. The ion source interlock system includes the following benefits: If a valid ion source is not installed or installed incorrectly, the high voltages to the ion source (both IonSpray voltage and the curtain plate voltage) are disabled and the quadrupole RF supplies are turned off. The TOF voltage supplies remain on. Detects the type of ion source for controlling the source exhaust system. When an omaldi source has been installed, the interlocks disable the laser system to prevent exposure to laser emissions, if the following occurs: the fiber optic cable is removed, the door is open, or vacuum pressure is not correct. Source Exhaust System All of the LC ion sources produce both sample and solvent vapors. These vapors represent a potential hazard to the laboratory environment. The source exhaust system is designed to safely remove and allow for the appropriate handling of the ion source exhaust products. WARNING! Take all necessary precautions to ensure the safe disposal of the source exhaust gases. The source exhaust system includes the following benefits: Draws vapors from the ion source using the Venturi system (a flow of gas through a Venturi tube). Provides an external connection to remove the exhaust from the laboratory, by fume hood or other venting system. Prevents operation of the instrument without the source exhaust system with the TurboIonSpray and Heated Nebulizer ion sources (these ion sources use large volumes of gas and heat to produce ions). NOTE: The source exhaust system slightly reduces the pressure in the ion source. The reduction in pressure has proven to be beneficial for the ionization performance of both the Heated Nebulizer and TurboIonSpray ion sources. Includes a pressure switch on the source exhaust pump for the following high-pressure scenarios: With the TurboIonSpray and Heated Nebulizer ion sources, shuts down the instrument. With the IonSpray ion source, shuts down the source exhaust pump and displays a warning ( The source exhaust pump is not operating )

6 on the applications computer. WARNING! The source exhaust system is necessary for samples containing toxic or highly volatile chemicals or solvents. Applied Biosystems/MDS SCIEX recommends you maintain at least 20% positive oxygen flow into the laboratory. Vacuum System The vacuum system which controls the pressure in the interface and the ion path chamber is critical to the operation of the API QSTAR Pulsar i instrument. High voltage to the ion source, the mass filters and associated ion optics, TOF and the detector are shut down if the vacuum system pressure is too high. The vacuum system includes the following components: Vacuum interface Vacuum control system NOTE: When using the omaldi source, the interface is removed and the sample is introduced directly into the Q0 rods from the source. Vacuum Interface The vacuum interface separates the low pressure ion path chamber from atmospheric pressure in the ion source. This allows the transfer of ions from the ion source to the mass spectrometer while restricting sample, solvent, and ambient air from entering the ion path chamber. This is accomplished using a gas curtain of dry nitrogen. The vacuum interface system includes the following components: Gas curtain interface Differentially-pumped interface Entrance optics Gas Curtain Interface The gas curtain interface is a small volume chamber at atmospheric pressure which is flushed with a pure, inert curtain gas (ultra high purity % nitrogen). Features of the gas curtain interface include: Provides a region for ion declustering: sample ions collide with the gas molecules, creating collisional energy which breaks down ions clusters and separates sample ions from solvent molecules. Pumps curtain gas into the interface at a rate ranging from 0 to approximately 3.0 L/min (at a maximum inlet pressure of 60 psi). Maintains a curtain gas flow of approximately 700 ml/min through the orifice plate into the differentially-pumped interface (the remainder flows back into the ion source through the aperture in the curtain plate). Allows you to control the curtain gas flow rate from the applications computer and is physically controlled by a gas flow controller. The gas line is connected to the gas curtain interface through a quick coupling on the bottom of the vacuum interface. If the curtain gas pressure falls below 40 psi, the instrument shuts down. Differentially-pumped Interface The differentially-pumped interface is the first low pressure stage in the

7 transition from the atmospheric pressure ion source to the low pressure ion path chamber. Features of the differentially-pumped interface include: Maintains pressure at approximately 1 to 2 torr using the rotary vane pump located outside of the main console. Controls the flow of ions with the following sequence: a) Draws curtain gas and ions from the gas curtain interface into the differentially pumped interface using the pressure differential across the orifice plate. b) Draws ions further into the differentially pumped interface using the difference in voltage between the orifice plate and the skimmer. c) Focuses ions into the ion path chamber through the aperture in the skimmer. For MS/MS experiments, feeds N2 gas to the collision cell (in the ion path chamber) as CAD gas. For MALDI applications, recommended CAD gas is argon, to ensure better fragmentation. NOTE: API QSTAR Pulsar i CAD gas is provided through a separate external connection to accommodate a different CAD gas. Entrance Optics You can control the flow of ions by modifying the voltage on any of the elements that constitute the entrance optics. Some entrance optics elements have an associated state file parameter that you can use to control the voltage from the applications computer. The entrance optics consist of the following elements: For a list of operational voltage ranges, see Appendix B: Generic Parameters. Entrance Optics Elements Element Function Curtain plate Separates the sample flow from the curtain gas flow Maintains a fixed voltage (not computer-controlled) For NanoSpray, includes toggle switch to connect curtain plate to the ring voltage, ensuring ring and curtain plate have the same voltage Orifice plate (OR) Provides a division between atmosphere and the approximately 1.2 torr pressure in the differentially-pumped interface Includes a 254 µm orifice Electrically isolated* Focusing ring (RNG) Focuses the ions through the skimmer into the ion path chamber Electrically isolated* *The orifice plate and the focusing ring are electrically isolated so that a variable declustering voltage of -350 to +375 V can be obtained between them. Vacuum Control System The vacuum control system is fundamental to the safe and reliable operation of the instrument. A stable ion path chamber pressure must be maintained to perform mass spectrometric analyses. This is accomplished using a staged pumping system. Features of the vacuum control system include: Automatically pumps down the ion path chamber when you start up the

8 instrument. Disables the instrument s analytical components until it can maintain a stable operating pressure. Continually monitors the pressure and several physical interlocks to determine the vacuum status. If the vacuum integrity is breached, shuts down the instrument's high voltages until the vacuum operating conditions are restored. The vacuum control system includes the following components: Pumping system Vacuum gauges Gas control system Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

TANDEM MASS SPECTROSCOPY

TANDEM MASS SPECTROSCOPY TANDEM MASS SPECTROSCOPY 1 MASS SPECTROMETER TYPES OF MASS SPECTROMETER PRINCIPLE TANDEM MASS SPECTROMETER INSTRUMENTATION QUADRAPOLE MASS ANALYZER TRIPLE QUADRAPOLE MASS ANALYZER TIME OF FLIGHT MASS ANALYSER

More information

Introduction to the Q Trap LC/MS/MS System

Introduction to the Q Trap LC/MS/MS System www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment ABI Q Trap LC/MS/MS Introduction to the Q Trap LC/MS/MS System The Q Trap

More information

Finnigan LCQ Advantage MAX

Finnigan LCQ Advantage MAX www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Finnigan LCQ Advantage MAX The Finnigan LCQ Advantage MAX ion trap mass spectrometer

More information

Thermo Finnigan LTQ. Specifications

Thermo Finnigan LTQ. Specifications IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Finnigan LTQ Specifications

More information

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics Mass spectrometry (MS) is the technique for protein identification and analysis by production of charged molecular species in vacuum, and their separation by magnetic and electric fields based on mass

More information

ABI 3200 Q TRAP LC/MS/MS System

ABI 3200 Q TRAP LC/MS/MS System www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL 001.847.913.0777 ABI 3200 Q TRAP LC/MS/MS System The advantages of an ion trap and the performance of a triple quad. All in one system.

More information

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Chemistry Instrumental Analysis Lecture 37. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 37 Most analytes separated by HPLC are thermally stable and non-volatile (liquids) (unlike in GC) so not ionized easily by EI or CI techniques. MS must be at

More information

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Scientific LTQ Orbitrap Velos

More information

Translational Biomarker Core

Translational Biomarker Core Translational Biomarker Core Instrumentation Thermo Scientific TSQ Quantum Triple Quadrupole Mass Spectrometers. There are two TSQ Quantum Ultra AM instruments available in the TBC. The TSQ Quantum Ultra

More information

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment LCQ Deca XP Plus Improved Ion Optics for Greater Sensitivity and Precision

More information

Accurate, High-Throughput Protein Identification Using the Q TRAP LC/MS/MS System and Pro ID Software

Accurate, High-Throughput Protein Identification Using the Q TRAP LC/MS/MS System and Pro ID Software www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment ABI Q Trap Pro LC/MS/MS Accurate, High-Throughput Protein Identification

More information

Mass Spectrometry in MCAL

Mass Spectrometry in MCAL Mass Spectrometry in MCAL Two systems: GC-MS, LC-MS GC seperates small, volatile, non-polar material MS is detection devise (Agilent 320-MS TQ Mass Spectrometer) Full scan monitoring SIM single ion monitoring

More information

Analysis of Polar Metabolites using Mass Spectrometry

Analysis of Polar Metabolites using Mass Spectrometry Analysis of Polar Metabolites using Mass Spectrometry TransMed Course: Basics in Clinical Proteomics and Metabolomics. Oct 10-19, 2012 dd.mm.yyyy Vidya Velagapudi, Ph.D, Adjunct Professor Head of the Metabolomics

More information

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC INTRODUCTION Principle: LC/MS is a technique that combines physical separation capabilities of liquid

More information

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

(Refer Slide Time 00:09) (Refer Slide Time 00:13) (Refer Slide Time 00:09) Mass Spectrometry Based Proteomics Professor Sanjeeva Srivastava Department of Biosciences and Bioengineering Indian Institute of Technology, Bombay Mod 02 Lecture Number 09 (Refer

More information

Agilent G3212 GC-APCI Source

Agilent G3212 GC-APCI Source Agilent G3212 GC-APCI Source Quick Start Guide Where to find information 2 Getting Started 3 Step 1. Start the Data Acquisition program for the GC and the Q-TOF 3 Step 2. Prepare the GC and Q-TOF for data

More information

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Chemistry Instrumental Analysis Lecture 34. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 34 From molecular to elemental analysis there are three major techniques used for elemental analysis: Optical spectrometry Mass spectrometry X-ray spectrometry

More information

Lecture 8: Mass Spectrometry

Lecture 8: Mass Spectrometry intensity Lecture 8: Mass Spectrometry Relative abundance m/z 1 Ethylbenzene experiment CH 2 CH 3 + m/z = 106 CH 2 + m/z = 91 C 8 H 10 MW = 106 CH + m/z = 77 + 2 2 What information can we get from MS spectrum?

More information

Lecture 8: Mass Spectrometry

Lecture 8: Mass Spectrometry intensity Lecture 8: Mass Spectrometry Relative abundance m/z 1 Ethylbenzene CH 2 CH 3 + m/z = 106 CH 2 + m/z = 91 C 8 H 10 MW = 106 CH + m/z = 77 + 2 2 What information can be obtained from a MS spectrum?

More information

M M e M M H M M H. Ion Sources

M M e M M H M M H. Ion Sources Ion Sources Overview of Various Ion Sources After introducing samples into a mass spectrometer, the next important step is the conversion of neutral molecules or compounds to gas phase ions. The ions could

More information

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS Mass Spectrometry Hyphenated Techniques GC-MS LC-MS and MS-MS Reasons for Using Chromatography with MS Mixture analysis by MS alone is difficult Fragmentation from ionization (EI or CI) Fragments from

More information

1. The range of frequencies that a measurement is sensitive to is called the frequency

1. The range of frequencies that a measurement is sensitive to is called the frequency CHEM 3 Name Exam 1 Fall 014 Complete these problems on separate paper and staple it to this sheet when you are finished. Please initial each sheet as well. Clearly mark your answers. YOU MUST SHOW YOUR

More information

API Optimization, Source Design, and Other Considerations of LC/MS

API Optimization, Source Design, and Other Considerations of LC/MS API Optimization, Source Design, and Other Considerations of LC/MS Instrument Design Considerations: The Atmosphere-Vacuum Interface and Pumping System The hows and whys of the vacuum? We ve got to get

More information

Lecture 15: Introduction to mass spectrometry-i

Lecture 15: Introduction to mass spectrometry-i Lecture 15: Introduction to mass spectrometry-i Mass spectrometry (MS) is an analytical technique that measures the mass/charge ratio of charged particles in vacuum. Mass spectrometry can determine masse/charge

More information

Quattro Micro - How does it work?

Quattro Micro - How does it work? Quattro Micro - How does it work? 1 Introduction This document is designed to familiarise you with the principles behind how the Quattro Micro works. The level of this document is designed as Level One

More information

Agilent ESI and APCI sources: for polar to non-polar compounds

Agilent ESI and APCI sources: for polar to non-polar compounds 1 Agilent 6400 Series Triple Quadrupole Users Workshop 1 Agilent ESI and APCI sources: for polar to non-polar compounds Nebulizer Pressure Corona current Nebulizer Pressure Vaporizer Vcap Vcap Drying Gas

More information

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n 20.2 Ion Sources electron ionization produces an M + ion and extensive fragmentation chemical ionization produces an M +, MH +, M +, or M - ion with minimal fragmentation MALDI uses laser ablation to transfer

More information

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Application Note EPA Method 535 EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS API 3200 LC/MS/MS System Overview Described here is the

More information

Molecular Mass Spectrometry

Molecular Mass Spectrometry Molecular Mass Spectrometry Mass Spectrometry: capable of providing information about (1) Elemental composition of samples of matter: atomic mass (2) Structures of inorganic, organic, and biological molecules

More information

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Application Note Authors Kevin McCann, Sameer Nene, Doug McIntyre, Edmond Neo, Dennis Nagtalon, and

More information

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Q&A Transcript ---------------- Q - How do you generate multiple charges reproductively? A - If you use the same settings on the

More information

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching s by Removal of Isobaric Interferences Differential Mobility Used as a Tool to Address Selectivity Challenges Adrian M. Taylor

More information

Mass Spectrometry. Fundamental LC-MS. Electrospray Ionisation Instrumentation

Mass Spectrometry. Fundamental LC-MS. Electrospray Ionisation Instrumentation Mass Spectrometry Fundamental LC-MS Electrospray Ionisation Instrumentation i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be

More information

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1 Agilent 6400 Series Triple Quadrupole Users Workshop 1 Agilent 6400 Series Triple Quadrupole Users Workshop QQQ Method Development and Optimization MassHunter Quantitation: Batch and Method setup QC s,

More information

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

Selecting an LC/MS Interface Becky Wittrig, Ph.D. Selecting an LC/MS Interface Becky Wittrig, Ph.D. RESTEK CORPORATION LC/MS Interfaces I. Background of LC/MS I. Historical Perspective II. Reasons for use II. Interfaces I. Transport devices II. Particle

More information

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD) The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD) Basically all compounds which are less volatile than the mobile phase can be detected. Detection is based on a Universal property of

More information

CHROMATOGRAPHY AND MASS SPECTROMETER

CHROMATOGRAPHY AND MASS SPECTROMETER 22 CHROMATOGRAPHY AND MASS SPECTROMETER 22.1 INTRODUCTION We know that the biochemistry or biological chemistry deals with the study of molecules present in organisms. These molecules are called as biomolecules

More information

LC-MS Based Metabolomics

LC-MS Based Metabolomics LC-MS Based Metabolomics Analysing the METABOLOME 1. Metabolite Extraction 2. Metabolite detection (with or without separation) 3. Data analysis Metabolite Detection GC-MS: Naturally volatile or made volatile

More information

The Easy Guide to: Inductively Coupled Plasma- Mass Spectrometry (ICP-MS)

The Easy Guide to: Inductively Coupled Plasma- Mass Spectrometry (ICP-MS) The Easy Guide to: Inductively Coupled Plasma- Mass Spectrometry (ICP-MS) By Arianne Bazilio & Jacob Weinrich December 2012 Contents Introduction... 2 Sample Introduction... 3 Torch... 4 Interface... 6

More information

Introduction to LC-MS

Introduction to LC-MS Wednesday April 5, 2017 10am Introduction to LC-MS Amy Patton, MS Laboratory Manager, Pinpoint Testing, LLC Little Rock, AR DESCRIPTION: Amy Patton, laboratory manager for Pinpoint Testing, will begin

More information

Ionization Techniques Part IV

Ionization Techniques Part IV Ionization Techniques Part IV CU- Boulder CHEM 5181 Mass Spectrometry & Chromatography Presented by Prof. Jose L. Jimenez High Vacuum MS Interpretation Lectures Sample Inlet Ion Source Mass Analyzer Detector

More information

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) The Agilent

More information

Thermo Scientific TSQ Quantum Ultra Ultra AM/Ultra EMR Performance Specifications

Thermo Scientific TSQ Quantum Ultra Ultra AM/Ultra EMR Performance Specifications IET International Equipment Trading, Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Scientific TSQ Quantum Ultra

More information

MS Goals and Applications. MS Goals and Applications

MS Goals and Applications. MS Goals and Applications MS Goals and Applications 3 Several variations on a theme, three common steps Form gas-phase ions choice of ionization method depends on sample identity and information required Separate ions on basis

More information

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Chemistry Instrumental Analysis Lecture 27. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 27 Gas Chromatography Introduction GC covers all chromatographic methods in which the mobile phase is gas. It may involve either a solid stationary phase (GSC)

More information

6.5 Optical-Coating-Deposition Technologies

6.5 Optical-Coating-Deposition Technologies 92 Chapter 6 6.5 Optical-Coating-Deposition Technologies The coating process takes place in an evaporation chamber with a fully controlled system for the specified requirements. Typical systems are depicted

More information

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Application Note Clinical Research Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Authors Yanan Yang 1, Victor Mandragon 2, and Peter Stone 1 1

More information

Electrospray Ion Trap Mass Spectrometry. Introduction

Electrospray Ion Trap Mass Spectrometry. Introduction Electrospray Ion Source Electrospray Ion Trap Mass Spectrometry Introduction The key to using MS for solutions is the ability to transfer your analytes into the vacuum of the mass spectrometer as ionic

More information

Mass spectrometry gas phase transfer and instrumentation

Mass spectrometry gas phase transfer and instrumentation Objectives of the Lecture spectrometry gas phase transfer and instrumentation Matt Renfrow January 15, 2014 1. Make ions 2. Separate/Analyze 3. Detect ions 4. What is mass resolution and mass accuracy?

More information

CHAPTER I. Introduction of HPLC, LC-MS/MS and aim of the work

CHAPTER I. Introduction of HPLC, LC-MS/MS and aim of the work CHAPTER I Introduction of HPLC, LC-MS/MS and aim of the work 13 GENERAL INTRODUCTION Quality control and quality assurance of pharmaceutical chemicals and their formulations are essential for ensuring

More information

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada) Quantitation and Identification of Pharmaceuticals and Personal Care Products (PPCP) in Environmental Samples using Advanced TripleTOF MS/MS Technology André Schreiber AB SCIEX Concord, Ontario (Canada)

More information

Selecting Detectors for Compounds with No Optical Absorbance

Selecting Detectors for Compounds with No Optical Absorbance C146-E114 Selecting Detectors for Compounds with No Optical Absorbance Technical Report vol.15 1. Features of Absorbance Detectors In HPLC, the detector is selected in accordance with the analyte. Many

More information

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Christopher Borton AB SCIEX Golden, Colorado verview Described here is the analysis of

More information

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed Mass Analyzers Double Focusing Magnetic Sector Quadrupole Mass Filter Quadrupole Ion Trap Linear Time-of-Flight (TOF) Reflectron TOF Fourier Transform Ion Cyclotron Resonance (FT-ICR-MS) Mass Analyzers

More information

Chapter 14. Molar Mass Distribution.

Chapter 14. Molar Mass Distribution. Chapter 14. Molar Mass Distribution. Difficulty with M n and M w, etc. osome polymers are hard to describe from just M n, M w, etc. o Examples: Bimodal, multimodal, nonuniform, broad, etc. MWDs. oin early

More information

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL 001.847.913.0777 for Certified, Refurbished Lab Equipment Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER TECHNICAL

More information

Types of Analyzers: Quadrupole: mass filter -part1

Types of Analyzers: Quadrupole: mass filter -part1 16 Types of Analyzers: Sector or double focusing: magnetic and electric Time-of-flight (TOF) Quadrupole (mass filter) Linear ion trap Quadrupole Ion Trap (3D trap) FTICR fourier transform ion cyclotron

More information

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Olaf Scheibner and Maciej Bromirski Thermo Fisher Scientific, Bremen, Germany Overview Purpose: Improve the performance

More information

LECTURE-13. Peptide Mass Fingerprinting HANDOUT. Mass spectrometry is an indispensable tool for qualitative and quantitative analysis of

LECTURE-13. Peptide Mass Fingerprinting HANDOUT. Mass spectrometry is an indispensable tool for qualitative and quantitative analysis of LECTURE-13 Peptide Mass Fingerprinting HANDOUT PREAMBLE Mass spectrometry is an indispensable tool for qualitative and quantitative analysis of proteins, drugs and many biological moieties to elucidate

More information

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 129 Infi nity LC, and 646 Triple Quadrupole LC/MS Application Note Clinical Research Authors Linda Côté and Christophe

More information

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS Application Note Authors E. Michael Thurman and Imma Ferrer Center for Environmental

More information

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY Edited by AKBAR MONTASER George Washington University Washington, D.C. 20052, USA WILEY-VCH New York Chichester Weinheim Brisbane Singapore Toronto CONTENTS

More information

Molecular Mass Spectrometry

Molecular Mass Spectrometry Molecular Mass Spectrometry Mass Spectrometry: capable of providing information about (1) Elemental composition of samples of matter: atomic mass (2) Structures of inorganic, organic, and biological molecules

More information

CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS

CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS Back to Basics Section D: Ion Optics CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS TABLE OF CONTENTS QuickGuide...413 Summary...415 Introduction...417 The physical basis of orthogonal TOF....... 419 Pulsedmainbeamsofions...421

More information

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York Mass Spectrometry for the Novice John Greaves and John Roboz (^>, yc**' CRC Press J Taylor & Francis Group Boca Raton London New York CRC Press is an imprint of the Taylor & Francis Croup, an informa business

More information

Other Methods for Generating Ions 1. MALDI matrix assisted laser desorption ionization MS 2. Spray ionization techniques 3. Fast atom bombardment 4.

Other Methods for Generating Ions 1. MALDI matrix assisted laser desorption ionization MS 2. Spray ionization techniques 3. Fast atom bombardment 4. Other Methods for Generating Ions 1. MALDI matrix assisted laser desorption ionization MS 2. Spray ionization techniques 3. Fast atom bombardment 4. Field Desorption 5. MS MS techniques Matrix assisted

More information

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365 Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365 Effortless Performance The LCMS-9030 quadrupole time-of-flight (Q-TOF) mass spectrometer integrates the world s fastest

More information

Extrel is widely respected for the quality of mass spectrometer systems that are

Extrel is widely respected for the quality of mass spectrometer systems that are Extrel is widely respected for the quality of mass spectrometer systems that are available to the world's top research scientists. In response to increasing requests for complete turn-key systems built

More information

BIOINF 4399B Computational Proteomics and Metabolomics

BIOINF 4399B Computational Proteomics and Metabolomics BIOINF 4399B Computational Proteomics and Metabolomics Sven Nahnsen WS 13/14 3. Chromatography and mass spectrometry Overview Recall last lecture Basics of liquid chromatography Algorithms to predict and

More information

MASS SPECTROMETRY. Topics

MASS SPECTROMETRY. Topics MASS SPECTROMETRY MALDI-TOF AND ESI-MS Topics Principle of Mass Spectrometry MALDI-TOF Determination of Mw of Proteins Structural Information by MS: Primary Sequence of a Protein 1 A. Principles Ionization:

More information

Improved Automated Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS

Improved Automated Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS Improved Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS Abstract In this work, we demonstrate an improved automated sample preparation for liquid chromatography-tandem mass spectrometry

More information

Introduction. Chapter 1. Learning Objectives

Introduction. Chapter 1. Learning Objectives Chapter 1 Introduction Learning Objectives To understand the need to interface liquid chromatography and mass spectrometry. To understand the requirements of an interface between liquid chromatography

More information

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS Application Note Food Testing and Agriculture Author Chen-Hao (Andy) Zhai and Rong-jie Fu Agilent Technologies (Shanghai)

More information

Mass Spectrometry (MS)

Mass Spectrometry (MS) Mass Spectrometry (MS) Alternative names: Mass spectrometric (selective) detector (MSD) Spectrometry - methods based on interaction of matter and radiation Mass spectrometry - method based on formation

More information

Selecting and planning for the right mass spectrometer

Selecting and planning for the right mass spectrometer Selecting and planning for the right mass spectrometer MSACL US 2018 Palm Springs, CA Wednesday, January 24th Deborah French Ph.D., DABCC, FACB University of California San Francisco Learning Objectives

More information

Analyst Software. Automatic Optimization Tutorial

Analyst Software. Automatic Optimization Tutorial This document is provided to customers who have purchased AB Sciex equipment to use in the operation of such AB Sciex equipment. This document is copyright protected and any reproduction of this document

More information

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis Updated: 10 December 2014 Print version CEE 772: Instrumental Methods in Environmental Analysis Lecture #21 Mass Spectrometry: Mass Filters & Spectrometers (Skoog, Chapt. 20, pp.511 524) (Harris, Chapt.

More information

Accurate Mass Analysis of Hydraulic Fracturing Waters

Accurate Mass Analysis of Hydraulic Fracturing Waters Application Note Environmental Accurate Mass Analysis of Hydraulic Fracturing Waters Using the Kendrick mass defect with the Agilent LC/Q-TOF MS Authors E. Michael Thurman and Imma Ferrer Department of

More information

CEE 772: Instrumental Methods in Environmental Analysis

CEE 772: Instrumental Methods in Environmental Analysis Updated: 10 December 2014 Print version CEE 772: Instrumental Methods in Environmental Analysis Lecture #21 Mass Spectrometry: Mass Filters & Spectrometers (Skoog, Chapt. 20, pp.511-524) (Harris, Chapt.

More information

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session QQQ Method Development and Optimization MassHunter Quant: Method setup Peak detection optimization Quant troubleshooting David Presser Application

More information

MS Goals and Applications. MS Goals and Applications

MS Goals and Applications. MS Goals and Applications MS Goals and Applications 1 Several variations on a theme, three common steps Form gas-phase ions choice of ionization method depends on sample identity and information required Separate ions on basis

More information

Information Dependent Acquisition (IDA) 1

Information Dependent Acquisition (IDA) 1 Information Dependent Acquisition (IDA) Information Dependent Acquisition (IDA) enables on the fly acquisition of MS/MS spectra during a chromatographic run. Analyst Software IDA is optimized to generate

More information

Atomic Absorption Spectrometer ZEEnit P series

Atomic Absorption Spectrometer ZEEnit P series Atomic Absorption Spectrometer ZEEnit P series Technical Data ZEEnit series Update 07/2014 OBue 1/ 5 ZEEnit P series Variable high-end AA Spectrometer with Deuterium and Zeeman Background Correction with

More information

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward Bruker Daltonics EASY-nLC Tailored HPLC for nano-lc-ms Proteomics think forward Nano-HPLC World-Class Performance with a Small Footprint Bruker Daltonics presents a nano-lc system, perfectly integrated

More information

Gas Chromatography (Chapter 2 and 3 in The essence of chromatography)

Gas Chromatography (Chapter 2 and 3 in The essence of chromatography) Gas Chromatography 1. Introduction. Stationary phases 3. Retention in Gas-Liquid Chromatography 4. Capillary gas-chromatography 5. Sample preparation and injection 6. Detectors (Chapter and 3 in The essence

More information

Field-Free Atmospheric Ionization: Atmospheric Pressure Chemical Ionization & Electrospray

Field-Free Atmospheric Ionization: Atmospheric Pressure Chemical Ionization & Electrospray Field-Free Atmospheric Ionization: Atmospheric Pressure Chemical Ionization & Electrospray Edward W. Sheehan 1, Ross C. Willoughby 1, Robert Classon 2, and Dan Dodgen 2 1 Chem-Space Associates, Inc., Pittsburgh,

More information

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES CONTENTS 1. An overview of SIFT-MS 2. Principles of SIFT-MS a. Why chemical ionization? b. Why multiple reagent

More information

Mass spectrometry.

Mass spectrometry. Mass spectrometry Mass spectrometry provides qualitative and quantitative information about the atomic and molecular composition of inorganic and organic materials. The mass spectrometer produces charged

More information

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer 38 Current Trends in Mass Spectrometry November 6 Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer This article demonstrates the improved

More information

1) In what pressure range are mass spectrometers normally operated?

1) In what pressure range are mass spectrometers normally operated? Exercises Ionization 1) In what pressure range are mass spectrometers normally operated? Mass spectrometers are usually operated in the high vacuum regime to ensure mean free paths significantly longer

More information

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps ION ANALYZERS MASS ANALYSER sample Vacuum pumps Mass analysers - separate the ions according to their mass-to-charge ratio MASS ANALYSER Separate the ions according to their mass-to-charge ratio in space

More information

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies Page 1 Agilent GC/MS Portfolio Smallest footprint, single GC column 5975VL with 6850GC Industry leading

More information

MS/MS .LQGVRI0606([SHULPHQWV

MS/MS .LQGVRI0606([SHULPHQWV 0DVV6SHFWURPHWHUV Tandem Mass Spectrometry (MS/MS) :KDWLV0606" Mass spectrometers are commonly combined with separation devices such as gas chromatographs (GC) and liquid chromatographs (LC). The GC or

More information

Presentation Basic Introduction to Instrumentation Matrix Effects Challenges

Presentation Basic Introduction to Instrumentation Matrix Effects Challenges Keys to Implementing Mass Spectrometry in the Clinical Laboratory Paul J. Taylor Chromatography Mass Spectrometry Satellite Meeting, AACB 20th September, 2013 Dept of Clinical Pharmacology, Princess Alexandra

More information

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials Thermo Scientific ICP-MS solutions for the semiconductor industry Maximize wafer yields with ultralow elemental detection in chemicals and materials Trace impurity analysis in chemicals an used in the

More information

Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph

Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph SCIETIFIC ISTRUMET EWS 2016 Vol. 7 SEPTEMBER Technical magazine of Electron Microscope and Analytical Instruments. Technical Explanation Introduction of Hitachi Chromaster 5610 MS Detector for High Performance

More information

Introduction to Pharmaceutical Chemical Analysis

Introduction to Pharmaceutical Chemical Analysis Introduction to Pharmaceutical Chemical Analysis Hansen, Steen ISBN-13: 9780470661222 Table of Contents Preface xv 1 Introduction to Pharmaceutical Analysis 1 1.1 Applications and Definitions 1 1.2 The

More information

LC MS analysis of metabolites. Basis of Chromatography

LC MS analysis of metabolites. Basis of Chromatography GBS 724 LC MS analysis of metabolites Stephen Barnes, PhD 4 7117; sbarnes@uab.edu Basis of Chromatography A moving (mobile) phase passes over an inert, stationary phase The compounds differentially interact

More information

MICROMASS Q-Tof micro MASS SPECTROMETER

MICROMASS Q-Tof micro MASS SPECTROMETER www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment MICROMASS Q-Tof micro MASS SPECTROMETER QTOF Micro Performance Specifications

More information

Atomic Spectroscopy AA/ICP/ICPMS:

Atomic Spectroscopy AA/ICP/ICPMS: Atomic Spectroscopy AA/ICP/ICPMS: A Comparison of Techniques VA AWWA/VWEA Lab Practices Conference July 25, 2016 Dan Davis Shimadzu Scientific Instruments AA/ICP/ICPMS: A Comparison of Techniques Topics

More information