Data Acquisition. What choices need to be made?
|
|
- Shanon Hunt
- 5 years ago
- Views:
Transcription
1 1
2 Specimen type and preparation Radiation source Wavelength Instrument geometry Detector type Instrument setup Scan parameters 2
3 Specimen type and preparation Slide mount Front loading cavity Back loading cavity Side drifting cavity Low backgrd plate Several spherical particle techniques 3
4 Specimen type and preparation Slide mount Front loading cavity Back loading cavity Side drifting cavity Low backgrd plate Several spherical particle techniques Preferred orientation is worst prep problem 4
5 Preferred orientation 5
6 Preferred orientation 6
7 Specimen type and preparation Slide mount Front loading cavity Back loading cavity Side drifting cavity Low backgrd plate Several spherical particle techniques Low angle problem - fixed divergence slit: X specimen 7
8 Specimen type and preparation To get good particle statistics, generally want size < 10 µ Poorly ground sample: 8
9 Specimen type and preparation Slide mount Front loading cavity Back loading cavity Side drifting cavity Low backgrd plate Several spherical particle techniques Neutron diffraction requires larger specimens 9
10 Radiation sources Lab x-rays Rotating anode x-rays Synchrotron x-rays Constant wavelength neutrons TOF neutrons 10
11 X-rays vs neutrons X-rays - atomic scatt power (ƒ) decreases w/ 2Θ Neutrons - atom scatt cross sections constant w/ 2Θ 11
12 X-rays vs neutrons X-rays - low atomic no. ƒs very small Neutrons - little variation of atom scatt cross sections w/ atomic no. 12
13 X-rays vs neutrons X-rays - low atomic no. ƒs very small Neutrons - little variation of atom scatt cross sections w/ atomic no. magnetic spin use for magnetic structure detn 13
14 X-rays vs neutrons X-rays - usually α 1 -α 2 doublet used (not w/ synchrotron x-rays) 14
15 X-rays vs neutrons 15
16 Radiation sources Lab x-rays relatively low intensity Rotating anode x-rays much higher intensity 16
17 Radiation sources Lab x-rays relatively low intensity Rotating anode x-rays much higher intensity Synchrotron x-rays extremely high intensity monochromatic continuously variable wavelength very tiny beam 17
18 Radiation sources Lab x-rays relatively low intensity Rotating anode x-rays much higher intensity Synchrotron x-rays extremely high intensity monochromatic very high resolution continuously variable wavelength very tiny beam 18
19 Radiation sources Reactor neutrons continuous wavelength distribution monochromator req'd 19
20 Radiation sources Reactor neutrons continuous wavelength distribution monochromator req'd generally low flux, low resolution 20
21 Radiation sources Spallation source (pulsed) time-of-flight (TOF) energy (wavelength) analysis used 21
22 Radiation sources Spallation source (pulsed) time-of-flight (TOF) energy (wavelength) analysis used very high flux, high resolution 22
23 Radiation sources Spallation source (pulsed) time-of-flight (TOF) energy (wavelength) analysis used very high flux, high resolution 23
24 Wavelength Shorter wavelengths more Bragg peaks more peak overlap 24
25 Wavelength Shorter wavelengths more Bragg peaks more peak overlap (keep in mind peak broadening due to sample and/or no. phases present) 25
26 Wavelength Shorter wavelengths more Bragg peaks more peak overlap (keep in mind peak broadening due to sample and/or no. phases present) X-rays most atom types have very strong absorption of characteristic wavelengths 26
27 Instrument geometry Choices: a. conventional Bragg-Brentano diffractometer (includes Θ-Θ) b. Guinier camera or diffractometer c. diffractometer w/ curved PSD d. TOF neutron instrument e. 4-circle diffractometer 27
28 Instrument geometry Choices: a. conventional Bragg-Brentano diffractometer (includes Θ-Θ) b. Guinier camera or diffractometer c. diffractometer w/ curved PSD d. TOF neutron instrument e. 4-circle diffractometer Generally want good resolution & high intensity can be obtained w/ all but (c) above, & (a) w/reactor neutrons (CW) 28
29 Instrument geometry Choices: a. conventional Bragg-Brentano diffractometer (includes Θ-Θ) b. Guinier camera or diffractometer c. diffractometer w/ curved PSD d. TOF neutron instrument e. 4-circle diffractometer Generally want good resolution & high intensity can be obtained w/ all but (c) above, & (a) w/reactor neutrons (CW) Instrument geometry affects instrument file 29
30 Detector type Conventional scintillation or proportional counter energy resolution not high usually need monochromator 30
31 Detector type Conventional scintillation or proportional counter energy resolution not high usually need monochromator Also common solid state detector very high energy resolution monochromator not needed 31
32 Detector type Conventional scintillation or proportional counter energy resolution not high usually need monochromator Also common solid state detector very high energy resolution monochromator not needed Neutrons He counter 32
33 Detector type Conventional scintillation or proportional counter energy resolution not high usually need monochromator Also common solid state detector very high energy resolution monochromator not needed Neutrons He counter What about image plates? poor resolution, hi bkgrd 33
34 Instrument setup Divergence and receiving slit sizes 34
35 Instrument setup Divergence and receiving slit sizes Theta-compensating divergence slit keeps irradiated area constant, But changes intensity distribution vs 2Θ 35
36 Instrument setup Divergence and receiving slit sizes 36
37 Instrument setup Divergence and receiving slit sizes 37
38 Instrument setup Divergence and receiving slit sizes Use of monochromator changes polarization correction in LP factor Integrated intensities of Bragg reflections: I hkl = scale factor x mult factor hkl x LP Θ x absorb factor Θ x pref orient factor hkl x extinction factor hkl x F hkl 2 38
39 Scan setup Scan range no. of reflections want >5 x no. parameters refined wavelength dependent low angle reflections may not be useful due to specimen configuration larger inherent instrumental errors extinction effects 39
40 Scan setup Step size sample dependent - peak widths need 5 observations across top of peak usually Θ 40
41 Scan setup Step size sample dependent - peak widths need 5 observations across top of peak usually Θ Count time longer times > higher intensities > greater precision at some point, little improvement in refinement process for longer count times 41
42 Specimen type and preparation Radiation source Wavelength Instrument geometry Detector type Instrument setup Scan parameters Choose according to objective(s) of experiment 42
Diffractometer. Geometry Optics Detectors
Diffractometer Geometry Optics Detectors Diffractometers Debye Scherrer Camera V.K. Pecharsky and P.Y. Zavalij Fundamentals of Powder Diffraction and Structural Characterization of Materials. Diffractometers
More informationSwanning about in Reciprocal Space. Kenneth, what is the wavevector?
Swanning about in Reciprocal Space or, Kenneth, what is the wavevector? Stanford Synchrotron Radiation Laboratory Principles The relationship between the reciprocal lattice vector and the wave vector is
More informationNeutron Instruments I & II. Ken Andersen ESS Instruments Division
Neutron Instruments I & II ESS Instruments Division Neutron Instruments I & II Overview of source characteristics Bragg s Law Elastic scattering: diffractometers Continuous sources Pulsed sources Inelastic
More informationX-rays. X-ray Radiography - absorption is a function of Z and density. X-ray crystallography. X-ray spectrometry
X-rays Wilhelm K. Roentgen (1845-1923) NP in Physics 1901 X-ray Radiography - absorption is a function of Z and density X-ray crystallography X-ray spectrometry X-rays Cu K α E = 8.05 kev λ = 1.541 Å Interaction
More informationStructure Report for J. Reibenspies
X-ray Diffraction Laboratory Center for Chemical Characterization and Analysis Department of Chemistry Texas A & M University Structure Report for J. Reibenspies Project Name: Sucrose Date: January 29,
More informationANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION
173 ANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION N. A. Raftery, L. K. Bekessy, and J. Bowpitt Faculty of Science, Queensland University of Technology, GPO Box 2434,
More informationSAXS and SANS facilities and experimental practice. Clement Blanchet
SAXS and SANS facilities and experimental practice Clement Blanchet SAS experiment Detector X-ray or neutron Beam Sample 2 s Buffer X-rays Roengten, 1895 Electromagnetic wave The electromagnetic spectrum
More informationGEANT4 simulation of the 10 B-based Jalousie detector for neutron diffractometers
GEANT4 simulation of the 10 B-based Jalousie detector for neutron diffractometers Irina Stefanescu 1, R. Hall-Wilton 1, G. Kemmerling 2, M. Klein 3, C.J. Schmidt 3,4, W. Schweika 1,2 1 European Spallation
More informationTHE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS DIFFRACTION DATA
Copyright(c)JCPDS-International Centre for Diffraction Data 2001,Advances in X-ray Analysis,Vol.44 96 THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS
More informationDelft in Europe. Neutron & Positrons Oyster & the World
Delft in Europe Neutron & Positrons Oyster & the World where are we? Oyster - HOR Neutrons and Positrons European Spallation Source where are we? Oyster - HOR Neutrons and Positrons European Spallation
More informationChemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631
Chemistry 4631 Instrumental Analysis Lecture 19 Chapter 12 There are three major techniques used for elemental analysis: Optical spectrometry Mass spectrometry X-ray spectrometry X-ray Techniques include:
More informationChemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy
Topic 2b: X-ray Fluorescence Spectrometry Text: Chapter 12 Rouessac (1 week) 4.0 X-ray Fluorescence Download, read and understand EPA method 6010C ICP-OES Winter 2009 Page 1 Atomic X-ray Spectrometry Fundamental
More informationIntroduction to Quantitative Analysis
ntroduction to Quantitative Analysis Qualitative: D phases by comparison with standard patterns. Estimate of proportions of phases by comparing peak intensities attributed to the identified phases with
More informationX-ray diffraction geometry
X-ray diffraction geometry Setting controls sample orientation in the diffraction plane. most important for single-crystal diffraction For any poly- (or nano-) crystalline specimen, we usually set: 1 X-ray
More informationSchool on Pulsed Neutrons: Characterization of Materials October Neurton Sources & Scattering Techniques (1-2)
1866-6 School on Pulsed Neutrons: Characterization of Materials 15-26 October 2007 Neurton Sources & Scattering Techniques (1-2) Guenter Bauer Forschungzentrum Julich GmbH Julich Germany The Abdus Salam
More informationPerformance of high pressure Xe/TMA in GEMs for neutron and X-ray detection
Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection R. Kreuger, C. W. E. van Eijk, Member, IEEE, F. A. F. Fraga, M. M. Fraga, S. T. G. Fetal, R. W. Hollander, Member, IEEE, L. M.
More informationRöntgenpraktikum. M. Oehzelt. (based on the diploma thesis of T. Haber [1])
Röntgenpraktikum M. Oehzelt (based on the diploma thesis of T. Haber [1]) October 21, 2004 Contents 1 Fundamentals 2 1.1 X-Ray Radiation......................... 2 1.1.1 Bremsstrahlung......................
More informationPrecision neutron flux measurement with a neutron beam monitor
Journal of Physics: Conference Series OPEN ACCESS Precision neutron flux measurement with a neutron beam monitor To cite this article: T Ino et al 2014 J. Phys.: Conf. Ser. 528 012039 View the article
More informationX-ray, Neutron and e-beam scattering
X-ray, Neutron and e-beam scattering Introduction Why scattering? Diffraction basics Neutrons and x-rays Techniques Direct and reciprocal space Single crystals Powders CaFe 2 As 2 an example What is the
More informationNeutron Diffraction: a general overview
RUG1 Neutron Diffraction: a general overview Graeme Blake Zernike Institute for Advanced Materials University of Groningen Outline Elastic scattering of neutrons from matter Comparison of neutron and X-ray
More informationHigh-Resolution Neutron Diffraction Monochromators for Neutron Diffractometry
High-Resolution Neutron Diffraction Monochromators for Neutron Diffractometry Pavol Mikula, Nuclear Physics Institute ASCR 25 68 Řež near Prague, Czech Republic NMI3-Meeting, Barcelona, 21 Motivation Backscattering
More informationGood Vibrations Studying phonons with momentum resolved spectroscopy. D.J. Voneshen 20/6/2018
Good Vibrations Studying phonons with momentum resolved spectroscopy D.J. Voneshen 20/6/2018 Overview What probe to use? Types of instruments. Single crystals example Powder example Thing I didn t talk
More informationThis paper should be understood as an extended version of a talk given at the
This paper should be understood as an extended version of a talk given at the Abstract: 1 st JINA workshop at Gull Lake, 2002. Recent experimental developments at LANL (Los Alamos, NM, USA) and CERN (Geneva,
More informationSmall Angle Neutron Scattering in Different Fields of Research. Henrich Frielinghaus
Small Angle Neutron Scattering in Different Fields of Research Henrich Frielinghaus Jülich Centre for Neutron Science Forschungszentrum Jülich GmbH Lichtenbergstrasse 1 85747 Garching (München) h.frielinghaus@fz-juelich.de
More informationNeutron facilities and generation. Rob McQueeney, Ames Laboratory and Iowa State University
Neutron facilities and generation Rob McQueeney, Ames Laboratory and Iowa State University September 12, 2018 19-Sep-18 Physics 502 2 Neutrons compared to other probes of matter Bulk probe Interacts with
More informationNeutron emission asymmetries from linearly polarized γ rays on nat Cd, nat Sn, and 181 Ta
Neutron emission asymmetries from linearly polarized γ rays on nat Cd, nat Sn, and 8 Ta Clarke Smith, Gerald Feldman, and the HIγS Collaboration George Triangle C. Smith, G. Feldman (GWU) Washington University
More informationChapter 2. X-ray X. Diffraction and Reciprocal Lattice. Scattering from Lattices
Chapter. X-ray X Diffraction and Reciprocal Lattice Diffraction of waves by crystals Reciprocal Lattice Diffraction of X-rays Powder diffraction Single crystal X-ray diffraction Scattering from Lattices
More informationPhysics 30: Chapter 5 Exam Wave Nature of Light
Physics 30: Chapter 5 Exam Wave Nature of Light Name: Date: Mark: /33 Numeric Response. Place your answers to the numeric response questions, with units, in the blanks at the side of the page. (1 mark
More informationHOW TO ANALYZE SYNCHROTRON DATA
HOW TO ANALYZE SYNCHROTRON DATA 1 SYNCHROTRON APPLICATIONS - WHAT Diffraction data are collected on diffractometer lines at the world s synchrotron sources. Most synchrotrons have one or more user facilities
More informationarxiv: v3 [nucl-ex] 18 May 2018
Observation of Pendellösung Fringes by Using Pulsed Neutrons Shigeyasu Itoh, Masaya Nakaji, Yuya Uchida, Masaaki Kitaguchi, and Hirohiko M. Shimizu Department of Physics, Nagoya University Furo-cho, Chikusa-ku,
More informationIntroduction to Triple Axis Neutron Spectroscopy
Introduction to Triple Axis Neutron Spectroscopy Bruce D Gaulin McMaster University The triple axis spectrometer Constant-Q and constant E Practical concerns Resolution and Spurions Neutron interactions
More informationLesson 2 Diffractometers & Phase Identification
Lesson 2 Diffractometers & Phase Identification Nicola Döbelin RMS Foundation, Bettlach, Switzerland February 11 14, 2013, Riga, Latvia Repetition: Generation of X-rays Kα 1 Target (Cu, Mo, Fe, Co,...)
More informationDetermination of the high- pressure phases (II and IV ) ) of. techniques
Determination of the high- pressure phases (II and IV ) ) of CuGeO 3 using single-crystal techniques Lauren A. Borkowski, 1,2 Barbara Lavina, 1,2 Przemyslaw Dera, 2 and Hanns-Peter Liermann 3 1 High Pressure
More informationX-ray Diffraction. Diffraction. X-ray Generation. X-ray Generation. X-ray Generation. X-ray Spectrum from Tube
X-ray Diffraction Mineral identification Mode analysis Structure Studies X-ray Generation X-ray tube (sealed) Pure metal target (Cu) Electrons remover inner-shell electrons from target. Other electrons
More informationNeutron Physics. The De Broglie relation for matter is: h mv (1) λ =
Neutron Physics Emily P. Wang MIT Department of Physics (Dated: November 11, 2004) Thermal neutrons in a beam emerging from the MIT research reactor were used to study the Maxwell-Boltzmann distribution,
More informationSSRL XAS Beam Lines Soft X-ray
SSRL SMB Summer School July 20, 2010 SSRL XAS Beam Lines Soft X-ray Thomas Rabedeau SSRL Beam Line Development Objective/Scope Objective - develop a better understanding of the capabilities and limitations
More informationDetekce a spektrometrie neutronů. neutron detection and spectroscopy
Detekce a spektrometrie neutronů neutron detection and spectroscopy 1. Slow neutrons 2. Fast neutrons 1 1. Slow neutrons neutron kinetic energy E a) charged particles are produced, protons, α particle,
More informationChanging and challenging times for service crystallography. Electronic Supplementary Information
Changing and challenging times for service crystallography Simon J Coles,* a and Philip A Gale* a Electronic Supplementary Information Instrument descriptions and experimental protocols The following firstly
More informationSupporting Information
Supporting Information Three-dimensional frameworks of cubic (NH 4 ) 5 Ga 4 SbS 10, (NH 4 ) 4 Ga 4 SbS 9 (OH) H 2 O, and (NH 4 ) 3 Ga 4 SbS 9 (OH 2 ) 2H 2 O. Joshua L. Mertz, Nan Ding, and Mercouri G.
More information& SUN ZhiJia 1;2. Abstract
Study on the imaging ability of the 2D neutron detector based on MWPC TIAN LiChao 1;2;3*, CHEN YuanBo 1;2, TANG Bin 1;2,ZHOU JianRong 1;2,QI HuiRong 1;2, LIU RongGuang 1;2, ZHANG Jian 1;2, YANG GuiAn 1;2,
More informationModeling of Li-Ion-Batteries to Optimize the Results Gained by Neutron Imaging
Modeling of Li-Ion-Batteries to Optimize the Results Gained by Neutron Imaging M.J. Mühlbauer Dr. A. Senyshyn, Dr. O. Dolotko, Prof. H. Ehrenberg SFB 595 Electrical Fatigue in Functional Materials Contact:
More informationData Collection. Overview. Methods. Counter Methods. Crystal Quality with -Scans
Data Collection Overview with a unit cell, possible space group and computer reference frame (orientation matrix); the location of diffracted x-rays can be calculated (h k l) and intercepted by something
More informationDetermination of the boron content in polyethylene samples using the reactor Orphée
Determination of the boron content in polyethylene samples using the reactor Orphée F. Gunsing, A. Menelle CEA Saclay, F-91191 Gif-sur-Yvette, France O. Aberle European Organization for Nuclear Research
More informationAndrew D. Kent. 1 Introduction. p 1
Compton Effect Andrew D. Kent Introduction One of the most important experiments in the early days of quantum mechanics (93) studied the interaction between light and matter; it determined the change in
More informationGeneral Overview of Gas Filled Detectors
GAS-FILLED DETECTOR General Overview of Gas Filled Detectors Gas-Filled Detectors Ion chamber Proportional counter G-M (Geiger-Miller) counter Diagram of a Generic Gas-Filled Detector A Anode High-voltage
More informationSupporting Information s for
Supporting Information s for # Self-assembling of DNA-templated Au Nanoparticles into Nanowires and their enhanced SERS and Catalytic Applications Subrata Kundu* and M. Jayachandran Electrochemical Materials
More informationNeutron Monochromators. Zahra Yamani Canadian Neutron Beam Centre, Chalk River, Canada
Neutron Monochromators Zahra Yamani Canadian Neutron Beam Centre, Chalk River, Canada Neutron Scattering Facilities NIST Centre for Neutron Research Canadian Neutron Beam Centre, Chalk River Labs Triple-Axis
More informationA RICH Photon Detector Module with G-APDs
A RICH Photon Detector Module with G-APDs S. Korpar a,b, H. Chagani b, R. Dolenec b, P. Križan b,c, R. Pestotnik b, A. Stanovnik b,c a University of Maribor, b J. Stefan Institute, c University of Ljubljana
More informationA neutron polariser based on magnetically remanent Fe/Si supermirrors
Jochen Stahn Laboratorium für Neutronenstreuung ETH Zürich & Paul Scherrer Institut A neutron polariser based on magnetically remanent Fe/Si supermirrors ILL, Grenoble 8. 0. 2006 neutron optics group PSI:
More informationAtomic and nuclear physics
Atomic and nuclear physics X-ray physics Attenuation of x-rays LEYBOLD Physics Leaflets P6.3.2.2 Investigating the wavelength dependency of the coefficient of attenuation Objects of the experiment To measure
More informationX-ray diffraction is a non-invasive method for determining many types of
Chapter X-ray Diffraction.1 Introduction X-ray diffraction is a non-invasive method for determining many types of structural features in both crystalline and amorphous materials. In the case of single
More informationLAB 01 X-RAY EMISSION & ABSORPTION
LAB 0 X-RAY EMISSION & ABSORPTION REPORT BY: TEAM MEMBER NAME: Ashley Tsai LAB SECTION No. 05 GROUP 2 EXPERIMENT DATE: Feb., 204 SUBMISSION DATE: Feb. 8, 204 Page of 3 ABSTRACT The goal of this experiment
More informationPowder Indexing of Difficult Cells using the Indexing Options within Topas. ACA, Orlando, May 28, 2005
Powder Indexing of Difficult Cells using the Indexing Options within Topas ACA, Orlando, May 28, 2005 Thanks to Alen Coehlo and Arnt Kern for writing and fostering Topas, and for endless help in using
More informationObservation of ferroelectric domains in bismuth ferrite using coherent diffraction techniques
Observation of ferroelectric domains in bismuth ferrite using coherent diffraction techniques James Vale October 25, 2011 Abstract Multiferroic materials have significant potential for both the scientific
More informationFocusing Optics. From x-ray telescopes to Compact Neutron Sources. Focus. Boris Khaykovich David Moncton Nuclear Reactor Laboratory, MIT
Focusing Optics for Neutrons: From x-ray telescopes to Compact Neutron Sources Focus Boris Khaykovich David Moncton Nuclear Reactor Laboratory, MIT Mikhail Gubarev Marshall Space Flight Center, NASA Jeffrey
More informationIMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE
Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 158 IMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE B. H.
More informationTransmission Electron Microscopy and Diffractometry of Materials
Brent Fultz James Howe Transmission Electron Microscopy and Diffractometry of Materials Fourth Edition ~Springer 1 1 Diffraction and the X-Ray Powder Diffractometer 1 1.1 Diffraction... 1 1.1.1 Introduction
More informationData collection Strategy. Apurva Mehta
Data collection Strategy Apurva Mehta Outline Before.. Resolution, Aberrations and detectors During.. What is the scientific question? How will probing the structure help? Is there an alternative method?
More informationAMOR the time-of-flight neutron reflectometer at SINQ/PSI
PRAMANA c Indian Academy of Sciences Vol. 63, No. 1 journal of July 2004 physics pp. 57 63 AMOR the time-of-flight neutron reflectometer at SINQ/PSI MUKUL GUPTA 1, T GUTBERLET 1, J STAHN 1, P KELLER 1
More informationLaser Optics-II. ME 677: Laser Material Processing Instructor: Ramesh Singh 1
Laser Optics-II 1 Outline Absorption Modes Irradiance Reflectivity/Absorption Absorption coefficient will vary with the same effects as the reflectivity For opaque materials: reflectivity = 1 - absorptivity
More informationBeamline Practice at BL02B2 (Powder diffraction)
Beamline Practice at BL02B2 (Powder diffraction) Rietveld Refinement using Synchrotron X-ray Powder Diffraction Data Shogo Kawaguchi, Bagautdin Bagautdinov, and Kunihisa Sugimoto (JASRI) 1. Introduction
More informationExperiment objectives: measure the ratio of Planck s constant to the electron charge h/e using the photoelectric effect.
Chapter 1 Photoelectric Effect Experiment objectives: measure the ratio of Planck s constant to the electron charge h/e using the photoelectric effect. History The photoelectric effect and its understanding
More informationLaboratory Manual 1.0.6
Laboratory Manual 1.0.6 Background What is X-ray Diffraction? X-rays scatter off of electrons, in a process of absorption and re-admission. Diffraction is the accumulative result of the x-ray scattering
More information2. Determine the excess charge on the outer surface of the outer sphere (a distance c from the center of the system).
Use the following to answer question 1. Two point charges, A and B, lie along a line separated by a distance L. The point x is the midpoint of their separation. 1. Which combination of charges will yield
More informationThe Spectrophotometer and Atomic Spectra of Hydrogen Physics 246
The Spectrophotometer and Atomic Spectra of Hydrogen Physics 46 Introduction: When heated sufficiently, most elements emit light. With a spectrometer, the emitted light can be broken down into its various
More informationJ-PARC and the prospective neutron sciences
PRAMANA c Indian Academy of Sciences Vol. 71, No. 4 journal of October 2008 physics pp. 629 638 J-PARC and the prospective neutron sciences MASATOSHI ARAI J-PARC Center, Japan Atomic Energy Agency, Tokai,
More informationPOLYCAPILLARY OPTICS BASED NEUTRON FOCUSING FOR SMALL SAMPLE NEUTRON CRYSTALLOGRAPHY
Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 306 POLYCAPILLARY OPTICS BASED NEUTRON FOCUSING FOR SMALL SAMPLE NEUTRON CRYSTALLOGRAPHY W.M. Gibson
More informationPhysics 126 Practice Exam #4 Professor Siegel
Physics 126 Practice Exam #4 Professor Siegel Name: Lab Day: 1. Light is usually thought of as wave-like in nature and electrons as particle-like. In which one of the following instances does light behave
More informationRIETVELD REFINEMENT WITH XRD AND ND: ANALYSIS OF METASTABLE QANDILITE-LIKE STRUCTURES
Copyright JCPDS - International Centre for Diffraction Data 2004, Advances in X-ray Analysis, Volume 47. 261 RIETVELD REFINEMENT WITH XRD AND ND: ANALYSIS OF METASTABLE QANDILITE-LIKE STRUCTURES G. Kimmel
More informationTEP Examination of the structure of NaCl monocrystals with different orientations
Examination of the structure of NaCl TEP Related topics Characteristic X-radiation, energy levels, crystal structures, reciprocal lattices, Miller indices, atomic form factor, structure factor, and Bragg
More informationBeamline practice at BL01B1 (XAFS) In-situ XAFS measurement of catalyst samples
Beamline practice at BL01B1 (XAFS) In-situ XAFS measurement of catalyst samples ver. 2015/09/18 T. Ina, K. Kato, T. Uruga (JASRI), P. Fons (AIST/JASRI) 1. Introduction The bending magnet beamline, BL01B1,
More informationNeutron and x-ray spectroscopy
Neutron and x-ray spectroscopy B. Keimer Max-Planck-Institute for Solid State Research outline 1. self-contained introduction neutron scattering and spectroscopy x-ray scattering and spectroscopy 2. application
More informationWhich of the following can be used to calculate the resistive force acting on the brick? D (Total for Question = 1 mark)
1 A brick of mass 5.0 kg falls through water with an acceleration of 0.90 m s 2. Which of the following can be used to calculate the resistive force acting on the brick? A 5.0 (0.90 9.81) B 5.0 (0.90 +
More informationBasics of XRD part III
Basics of XRD part III Dr. Peter G. Weidler Institute of Functional Interfaces IFG 1 10/31/17 KIT The Research University of the Helmholtz Association Name of Institute, Faculty, Department www.kit.edu
More informationMEASUREMENT OF TEMPORAL RESOLUTION AND DETECTION EFFICIENCY OF X-RAY STREAK CAMERA BY SINGLE PHOTON IMAGES
Proceedings of IBIC212, Tsukuba, Japan MEASUREMENT OF TEMPORAL RESOLUTION AND DETECTION EFFICIENCY OF X-RAY STREAK CAMERA BY SINGLE PHOTON IMAGES A. Mochihashi, M. Masaki, S. Takano, K. Tamura, H. Ohkuma,
More informationSOLID STATE 9. Determination of Crystal Structures
SOLID STATE 9 Determination of Crystal Structures In the diffraction experiment, we measure intensities as a function of d hkl. Intensities are the sum of the x-rays scattered by all the atoms in a crystal.
More informationDetermination of Absolute Neutron Fluence to sub-0.1% uncertainty (and better)
Determination of Absolute Neutron Fluence to sub-0.1% uncertainty (and better) Andrew Yue University of Maryland / NIST for the Alpha-Gamma Collaboration NIST-ILL-Sussex neutron lifetime experiments Neutron
More informationX-Ray Photoelectron Spectroscopy (XPS)
X-Ray Photoelectron Spectroscopy (XPS) Louis Scudiero http://www.wsu.edu/~scudiero; 5-2669 Fulmer 261A Electron Spectroscopy for Chemical Analysis (ESCA) The basic principle of the photoelectric effect
More informationV. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber
CYRIC Annual Report 2001 V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber Kawata N. Baba M. Kato M.*, Miura T.**, and Yamadera A.***, Cyclotron and Radioisotope Center, Tohoku
More informationScattering Lecture. February 24, 2014
Scattering Lecture February 24, 2014 Structure Determination by Scattering Waves of radiation scattered by different objects interfere to give rise to an observable pattern! The wavelength needs to close
More informationMeasurments with Michelson interferometers
Please do not remove this manual from from the lab. It is available at www.cm.ph.bham.ac.uk/y2lab Optics Measurments with Michelson interferometers Objectives In this experiment you will: Understand the
More informationX-Ray Photoelectron Spectroscopy (XPS)
X-Ray Photoelectron Spectroscopy (XPS) Louis Scudiero http://www.wsu.edu/~scudiero; 5-2669 Electron Spectroscopy for Chemical Analysis (ESCA) The basic principle of the photoelectric effect was enunciated
More informationX-ray absorption. 4. Prove that / = f(z 3.12 ) applies.
Related topics Bremsstrahlung, characteristic radiation, Bragg scattering, law of absorption, mass absorption coefficient, absorption edge, half-value thickness, photoelectric effect, Compton scattering,
More informationAbsorption of X-rays
Absorption of X-rays TEP Related topics Bremsstrahlung, characteristic X-radiation, Bragg scattering, law of absorption, mass absorption coefficient, absorption edges, half-value thickness, photoelectric
More informationPHYS 4 CONCEPT PACKET Complete
PHYS 4 CONCEPT PACKET Complete Written by Jeremy Robinson, Head Instructor Find Out More +Private Instruction +Review Sessions WWW.GRADEPEAK.COM Need Help? Online Private Instruction Anytime, Anywhere
More informationDIFFRACTION PHYSICS THIRD REVISED EDITION JOHN M. COWLEY. Regents' Professor enzeritus Arizona State University
DIFFRACTION PHYSICS THIRD REVISED EDITION JOHN M. COWLEY Regents' Professor enzeritus Arizona State University 1995 ELSEVIER Amsterdam Lausanne New York Oxford Shannon Tokyo CONTENTS Preface to the first
More informationExperiment O-2. The Michelson Interferometer
Experiment O-2 The Michelson Interferometer The Michelson interferometer is one of the best known and historically important interferometers. It is a very accurate length-measuring device and has been
More informationDevelopment of Scintillator Detectors at J-PARC/MLF
Development of Scintillator Detectors at J-PARC/MLF J-PARC, JAEA Kazuhiko Soyama Basic Energy Sciences Neutron & Photon Detector Workshop August 1-3, 2012 Holiday Inn Gaithersburg, USA Contents 1. J-PARC,
More informationX-Ray Emission and Absorption
X-Ray Emission and Absorption Author: Mike Nill Alex Bryant February 6, 20 Abstract X-rays were produced by two bench-top diffractometers using a copper target. Various nickel filters were placed in front
More informationLight Source I. Takashi TANAKA (RIKEN SPring-8 Center) Cheiron 2012: Light Source I
Light Source I Takashi TANAKA (RIKEN SPring-8 Center) Light Source I Light Source II CONTENTS Introduction Fundamentals of Light and SR Overview of SR Light Source Characteristics of SR (1) Characteristics
More informationHow Does It All Work? A Summary of the IDEAS Beamline at the Canadian Light Source
How Does It All Work? A Summary of the IDEAS Beamline at the Canadian Light Source What Makes Up The Canadian Light Source? 4. Storage Ring 5. Synchrotron Light 6. Beamline 1. Electron Gun 2. Linear Accelerator
More informationJoe Parker for the Cosmic Ray γ Group Kyoto University
Joe Parker for the Cosmic Ray γ Group Kyoto University Cosmic Ray Group NID Project Team @ 京大 K. Hattori, C. Ida, S. Iwaki, S. Kabuki, H. Kubo, S. Kurosawa, K. Miuchi, H. Nishimura, J. D. Parker, T. Sawano,
More informationAtomic and nuclear physics
Atomic and nuclear physics X-ray physics Attenuation of x-rays LD Physics Leaflets P6.3.2.1 Investigating the attenuation of x-rays as a function of the absorber material and absorber thickness Objects
More informationJ. Am. Chem. Soc., 1998, 120(7), , DOI: /ja972816e
J. Am. Chem. Soc., 1998, 120(7), 1430-1433, DOI:10.1021/ja972816e Terms & Conditions Electronic Supporting Information files are available without a subscription to ACS Web Editions. The American Chemical
More informationRajesh Prasad Department of Applied Mechanics Indian Institute of Technology New Delhi
TEQIP WORKSHOP ON HIGH RESOLUTION X-RAY AND ELECTRON DIFFRACTION, FEB 01, 2016, IIT-K. Introduction to x-ray diffraction Peak Positions and Intensities Rajesh Prasad Department of Applied Mechanics Indian
More information2. A proton is traveling with velocity v, to the right, through a magnetic field pointing into the page as indicated in the figure below.
1. An electron has a mass of 9.11 x 10-31 kg and its charge is -1.6 x 10-19 C. The electron is released from rest in a vacuum between two flat, parallel metal plates that are 10 cm apart. The potential
More informationX-ray Diffraction from Materials
X-ray Diffraction from Materials 008 Spring Semester Lecturer; Yang Mo Koo Monday and Wednesday 4:45~6:00 8. X-ray Diffractometers Diffractometer: a measuring instrument for analyzing the structure of
More informationPS210 - Optical Techniques. Section VI
PS210 - Optical Techniques Section VI Section I Light as Waves, Rays and Photons Section II Geometrical Optics & Optical Instrumentation Section III Periodic and Non-Periodic (Aperiodic) Waves Section
More informationGood Diffraction Practice Webinar Series
Good Diffraction Practice Webinar Series High Resolution X-ray Diffractometry (1) Mar 24, 2011 www.bruker-webinars.com Welcome Heiko Ress Global Marketing Manager Bruker AXS Inc. Madison, Wisconsin, USA
More informationData processing and reduction
Data processing and reduction Leopoldo Suescun International School on Fundamental Crystallography 2014 May 1st, 2014 Reciprocal lattice c* b* b * dh' k' l' 1 dh' k' l' * dhkl 1 dhkl a a* 0 d hkl c bc
More information