ACCREDITED CALIBRATION AND MEASUREMENT CAPABILITY SCOPE. Ring gaugeф(50~100)mm U=1.1 μm

Size: px
Start display at page:

Download "ACCREDITED CALIBRATION AND MEASUREMENT CAPABILITY SCOPE. Ring gaugeф(50~100)mm U=1.1 μm"

Transcription

1 Name: Shanghai Institute of Quality Inspection and Technical Research Address: No.627, Yongjia Road, Shanghai, China Registration Accreditation Criteria: ISO/IEC and relevant requirements of CNAS Effective Date: SCHEDULE 5 : The instruments with * represents onsite calibration can be performed. ACCREDITED CALIBRATION AND MEASUREMENT CAPABILITY SCOPE 一 几何量 1 Radius Gauges Radius Gauges JJG58 (1.0~25)mm U=5μm l n 2 Plain Limit Gauges Plain Limit Gauges JJG343 Plug gaugeф(1~50)mm Plug gaugeф(50~100)mm Ring gaugeф(1~50)mm U=0.9 μm U=1.0 μm U=1.0 μm 3 4 Cylindrical Thread Gauges Cylindrical Measuring Pin Ring gaugeф(50~100)mm U=1.1 μm Plug gaugeф(1~200)mm Caliration Specification for Cylindrical Thread Gauges JJF1345 Ring gaugeф(1~200)mm Cylindrical Measuring Pin JJF1207 (0.118~6.585)mm U=(2.8~3.2)μm U=(3.4~3.8) μm U=0.56μm 5 Screw Templates pitch Screw Templates JJG60 P(0.40~6.00)mm U=3.1μm 第 1 页共 15 页

2 half of thread angle 6 *Surface Plates Surface Plates JJG117 7 *Height Measuring Instrument with Digital Display 8 Feeler thickness Feeler Gauges JJG62 55 /60 U=7 ( ) mm~( ) mm U=(0.4~1.0)μm ( ) mm~( )mm U=(1.0~1.7)μm ( )mm ~(1500 U=(1.7~2.5)μm 1000)mm ( )mm ~( )mm U=(2.5~2.8)μm ( )mm ~( )mm U=(2.8~4.1)μm Height Measuring Instrument with Digital (0~1000)mm U=1.8μm Display JJF1254 (0.02~0.10)mm (0.15~3.00)mm U=2μm U=3μm 9 Test sieve Test Sieves JJF1175 aperture:(5~125)mm U=27μm aperture:(0.020~4.75)mm U=(2~5)μm 10 Gauge Blocks Gauge Blocks JJG146 (0.5~100)mm (100~1000)mm U=0.06μm l n U=0.12μm l n Flatness Optical Flat(D30~D100)mmU=0.02μm 11 Optical Flat Flatness Parallelism Optical Flat JJG28 Parallel Optical Flat(15.00~ U=0.02μm 91.00)mm Parallel Optical Flat(15.00~ U=0.1μm 91.00)mm 第 2 页共 15 页

3 12 Angle Gauge Blocks Angle Angle Gauge Blocks JJG70 (0~360) U=7 13 Levels Angle 14 *Magnetic and Eddy Current Measuring Instrument for Coating Thickness Caliration Specification for Frame Levels and Shaft Levels JJF1084 Magnetic and Eddy Current Measuring Instrument for Coating Thickness JJG818 (0.02~0.10) mm/m U rel =5.8% (0~12)μm (>12~506)μm (>506~1000)μm (50~500)mm U=1μm U=6μm U=12μm U=5μm 15 Internal Micrometers Internal Micrometers JJG22 16 Steel Rule Steel Rule JJG1 (>500~1000)mm (>1000~1500)mm (>1500~2000)mm (0~500)mm (>500~1000)mm (>1000~2000)mm (0~100)mm U=8μm U=11μm U=15μm U=0.09mm U=0.10mm U=0.14mm U=0.5μm 17 Connector gauges Connector gauges (geometric parameters, force value, quality calibration specification) SQI/JL-JF- 35 (>100~200)mm (>200~400)mm (>400~800)mm (>800~1300)mm (>1300~1500)mm U=1.4μm U=1.6μm U=0.019mm 第 3 页共 15 页

4 (>1500~2000)mm U=0.025mm Verticality (0~200)mm U=0.8μm Straightness (0~200)mm U=0.8μm Symmetry (0~200)mm U=0.8μm Parallelism (0~2000)mm U=0.8μm Position degree (thread arc radius) (cap nbspcrest diameter) (cap thread) (thread pitch) (0~200)mm (0~5)mm (0~10)mm U=0.8μm U=0.015mm U=0.010mm Roundness (0~200)mm U=0.6μm Angle (0~360) U=8 Force value (0~500)N U=0.6N Quality (0~30)kg U=(6-18)g 18 Calibration specification for safety test kit Calibration specification for safety test kit (geometric parameter, force value, quality) SQI/JL-JF-34 (0~100)mm (>100~200)mm (>200~400)mm U=0.5μm 第 4 页共 15 页

5 (>400~800)mm (>800~1300)mm (>1300~1500)mm (>1500~2000)mm U=1.4μm U=1.6μm U=0.019mm U=0.025mm Verticality (0~200)mm U=0.8μm Straightness (0~200)mm U=0.8μm Symmetry (0~200)mm U=0.8μm Parallelism (0~2000)mm U=0.8μm Position degree (thread arc radius) (cap nbspcrest diameter) (cap thread) (thread pitch) (0~200)mm (0~5)mm (0~10)mm U=0.8μm U=0.015mm U=0.010mm Roundness (0~200)mm U=0.6μm Angle (0~360) U=8 Force value (0~500)N U=0.6N Quality (0~30)kg U=(6-18)g 第 5 页共 15 页

6 (0~100)mm (>100~200)mm (>200~400)mm U=0.5μm (>400~800)mm (>800~1300)mm (>1300~1500)mm (>1500~2000)mm U=1.4μm U=1.6μm U=0.019mm U=0.025mm 19 Calibration specification for toy testing equipment Verticality (0~200)mm U=0.8μm Straightness Calibration specification for toy (0~200)mm U=0.8μm testing equipment (geometric Symmetry parameters, force values, and (0~200)mm U=0.8μm Parallelism quality) SQI/JL-JF-37 (0~2000)mm U=0.8μm Position degree (thread arc radius) (cap nbspcrest diameter) (cap thread) (thread pitch) Roundness (0~200)mm (0~5)mm (0~10)mm (0~200)mm U=0.8μm U=0.015mm U=0.010mm U=0.6μm 第 6 页共 15 页

7 Angle (0~360) U=8 Force value (0~500)N U=0.6N Quality (0~30)kg U=(6-18)g (0~100)mm (>100~200)mm (>200~400)mm (>400~800)mm (>800~1300)mm (>1300~1500)mm U=0.5μm U=1.4μm U=1.6μm U=0.019mm 20 Specification for calibration of shell protection grade test equipment Specification for calibration of shell (>1500~2000)mm U=0.025mm Verticality protection grade test equipment (0~200)mm (geometric parameters, force values, U=0.8μm Straightness and quality) SQI/JL-JF-36 (0~200)mm U=0.8μm Symmetry (0~200)mm U=0.8μm Parallelism (0~2000)mm U=0.8μm Position degree (thread arc radius) (cap nbspcrest diameter) (0~200)mm (0~5)mm U=0.8μm 第 7 页共 15 页

8 (cap thread) (thread pitch) (0~10)mm U=0.015mm U=0.010mm Roundness (0~200)mm U=0.6μm 21 *Ultrasonic Thickness Instruments Angle (0~360) U=8 Force value (0~500)N U=0.6N Quality (0~30)kg U=(6-18)g Ultrasonic Thickness Instruments JJF 1126 resolution 0.1mm:(0~ 200)mm resolution 0.01mm:(0~ 10)mm resolution 0.01mm:(>10~ 75)mm resolution 0.01mm:(>75~ 200)mm U=0.1mm U=0.01mm U=0.02mm U=0.03mm Φ30mm standard round tube U=0.02mm Φ40mm standard round tube U=0.04mm 22 *Current Calipers Current Calipers JJG30 (0~500)mm (0~1000)mm (0~1500)mm (0~2000)mm U=(0.008~0.02)mm U=0.04mm U=0.05mm U=0.06mm 23 *Height Gauge Height Caliper JJG31 (0~600) mm U=0.008 mm 第 8 页共 15 页

9 Reading in 0.01mm(0~3) U=5.3μm mm Reading in 0.01mm(>3~ 5)mm U=6.1μm Reading in 0.01mm(>5~ 10)mm U=6.7μm 24 Reading in 0.001mm(0~ U=1.3μm *Tester for Dial 0.5)mm Dial Gauges(dial and digital) JJG34 Indicator Gauges Reading in 0.001mm(> U=1.5μm 0.5~1.0)mm Reading in 0.001mm(> 1.0~2.0)mm U=1.7μm Reading in 0.001mm(> 2.0~3.0)mm U=2.1μm Reading in 0.001mm(> 3.0~5.0)mm U=2.7μm Reading in 0.001mm(0~ 1.0)mm U=0.2μm 25 *Measurement Reading in 0.001mm Tester for Dial Indicator Gauges U=0.3μm Standard Instrument (>1.0~2.0)m JJG201 of Roundness Reading in 0.01mm(0~ U=(1.0~1.3)μm 25) Grating type(0~50)mm U=(0.3~2.0)μm 26 *Wide Range Dial Gauges Reading in 0.01mm Wide Range Dauges Reading in 0.01mm JJG379 (0~10)mm (>10~20)mm (>20~30)mm U=5.8μm U=6.1μm U=7.2μm 第 9 页共 15 页

10 (>30~40)mm (>40~50)mm U=8.0μm U=9.2μm 27 *Bore Dial Indicator Calirbration Specification for Bore Dial Indicators JJF1102 (2~450)mm/0.01mm (2~450)mm/0.001mm U=(3.3~4.1)μm U=2.0μm (500~600)mm U=5.4μm (>600~900)mm U=7.1μm 28 *Outside Micrometers Calirbration Specification for Micrometers with Measuring Range from 500mm to 3000mm JJF1088 (>900~1200)mm (>1200~1500)mm U=8.5μm U=10μm (>1500~1800)mm U=12μm (>1800~2000)mm U=13μm 29 *Squares Squares JJG7 (0~600)mm U=4μm 30 *Straight Edge Sraight Edge JJG63 31 *Micrometer Micrometer JJG21 175mm (>175~ 300)mm (0~50)mm (>50~100)m (>100~200)mm (>200~300)mm (>300~400)mm (>400~ 500)mm U=0.3μm U=0.5μm U=1.2μm U=1.3μm U=1.6μm U=1.9μm U=2.2μm U=2.5μm 第 10 页共 15 页

11 32 *Dial test indicator Dial Test Indicator JJF35 33 *Universal Bevel Protractors Angle Universal Bevel Protractors JJG33 Reading in 0.01mm(0~1) mm Reading in 0.001mm:(0~ 0.4)mm (0~320) (0~360) (0~5)m (>5~10)m (>10~15)m U=3.8μm U=2.0μm U=0.8 U=2.1 U=0.3mm U=0.7mm U=1.0mm 34 Steel Tape Steel Tape JJG4 (>20~30)m (>30~50)m (>50~100)m (>100~150)m (>150~200)m U=2.0 mm U=3.3 mm U=6.6mm U=9.9mm U=13 mm Ra=0.2μm U rel = 4.8 % 35 Roughness Comparison Specimen roughness Calibration Specification of Roughness Comparison Specimens JJF1099 Ra=0.8μm U rel = 5.2 % Ra=1.6μm U rel = 4.8 % Ra=3.2μm U rel = 5.0 % Ra=6.3μm U rel = 4.8 % *Contact(Stylus) roughness Contact(Stylus) Instruments of (0.1~0.25)mm U rel =6.6% 第 11 页共 15 页

12 Surface Roughness Measurement by the Profile Method JJF1105 (>0.25~10)mm U rel =4.6% 37 Surface Roughness Measurement by the Profile Method *Instrument of Roundness and Cylindricity roundness Measurement Standard Instrument (1~20)μm U rel =1.8% of Roundness and Cylindricity height JJG429 (0.01~900)mm U rel =1.8% (-30~+30) μm U=0.11μm 38 *Optimeter Optimeter JJG45 (-60~+60) μm (-90~+90) μm (0~200)mm (>200~500)mm (>500~900)mm U=0.12μm U=0.12μm U=0.2μm U=(0.2~0.4)μm U=(0.4~0.6)μm 39 *Lengh Measuring Machine Measuring Machine JJF1066 (>900~1000)mm (>1000~1500)mm (>1500~2000)mm U=(0.6~0.7)μm U=(0.7~2.4)μm U=(2.4~3.0)μm (>2000~2500)mm U=(3.0~3.8)μm (>2500~3000)mm U=(3.8~4.5)μm (>3000~6000)mm U=(4.5~9.0)μm 40 *Lengh Measuring Instrument Measuring Machine Instrument JJF1189 (0~20)mm (>20~50)mm (>50~100)mm U=0.2μm U=(0.2~0.5)μm U=(0.5~0.8)μm 第 12 页共 15 页

13 (0~50)mm (>50~75)mm U=0.5μm U=(0.5~0.6)μm 41 *Toolmaker's Microscope Toolmaker's Microscope JJG56 (>75~100)mm (>100~125)mm (>125~150)mm U=(0.6~0.7)μm U=(0.7~0.9)μm U=(0.9~1.0)μm (>150~175)mm U=(1.0~1.2)μm (>175~200)mm U=(1.2~1.3)μm 42 *Coordinate Measuring Machine Coordinate Measuring Machine JJF1064 (0~1.35)m (0~3)m (0~22.5)m U=0.20μm L U=0.23μm L U=0.5μm L 43 *Projector 44 *Concentricity Tester *Metallographic Microscope *X-Ray Fluorescence Coating Thickness Instrument thickness Projectors JJF1093 (0~10)mm (>10~100)mm (>100~200)mm U=1.6μm U=(1.6~1.8)μm U=(1.8~2.4)μm Calirbration Specification for Concentricity Tester JJF1109 (0~1000)mm U=1.5μm Verification Regulation for metallographic microscope JJG( 教 5 ~100 U rel =1.0% 委 )012 X-Ray Au/Ni:1.48μm U rel =5.5 % Fluorescence Coating Thickness Instruments JJF1306 Ni/Cu:5.3μm U rel =5.2 % 第 13 页共 15 页

14 47 *Micrometer 48 *Reading Microscope *Measuring Microscope *Tool presetting and measuring instruments *Image probe measuringmachine measurement error (in measuring plane *Measuring System of Coordinate Position Au/Ni/Cu:Au 0.79μm Ni 2.38μm Zn/Fe:1.56μm,4.1μ m,13.2μm,33.1μm Ag:2.09μm,8.5μm, 18.7μm U rel =5.5 % U rel =5.8% Urel = 5.6% Au:0.053μm,3.28μm U rel =10% Cu:2.78μm,9.6μm, 24.5μm Ni:3.12μm,10.7μm,23.1 μm Pneumatic Measuring Instrument for (0~220)μm Micrometers JJG356 Reading Microscope and Measuring (0~8)mm Microscope JJG571 Reading Microscope and Measuring (0~50)mm Microscope JJG571 Verification Regulation of Tool Presetting and Measuring (0~1000)mm Instruments JJG938 U rel =6.0% U rel =5.9% U=0.5μm U=0.22μm U=3.3μm U=5.6μm XY axis:(0~700)mm U=2.2μm Imaging Probe Measuring Machines JJF Z axis:(0~100)mm U=0.46μm Measuring System of Coordinate Position JJF1251 L=(0~1)m L=(1~5)m L=(5~10)m U=4.3μm U=(4.3~8.1)μm U=(8.1~16)μm 第 14 页共 15 页

15 L=(10~15)m L=(15~20)m L=(20~30)m L=(30~40)m U=(16~24)μm U=(24~32)μm U=(32~56)μm U=(56~75)μm 二 力学 1 2 三 光学 1 Coordinate Measuring Spheres Roundness Flick Calibration Standard Roundness Standard Torque Wrench Static Torque Measuring Devices angle α=0 ~360 U=1.4 (0~100)mm U=0.15μm Coordinate Measuring Spheres Roundness JJF1422 (0~100)mm U=0.03μm Roundness Flick Calibration (0.01~1000)μm U rel =5.5% Standard JJF1485 torque torque Vertification Regulation of Standard (0.1~1000)Nm Torque Wrench JJG 1103 Vertification Regulation of Static Torque Measuring Devices JJG 995 (0.1~1000)Nm Optical Power Meters Optical Power Meters in in Optical Power Telecommunication JJG 965 Telecommunication 2 *Laser Power Meters Laser Power 0.1mW~200WLaser Power Meters JJG 249 (-60~5)dBm, λ= 1310nm,1550nm (5~10)dBm, λ= 1310nm,1550nm U rel =(0.09%~0.38%) U rel=(0.08%~0.35%) U=0.18dB U=0.43dB (1~90)mW U rel =3.2% 第 15 页共 15 页

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 A.A. JANSSON Inc. 2070 Airport Road Waterford, MI 48327-1204 Justin Frazzini Phone: 248 674 4811 CALIBRATION Valid To: August 31, 2016

More information

ACCREDITED LABORATORY. INSPECTION MEASUREMENT COMPANY Wyoming, MI

ACCREDITED LABORATORY. INSPECTION MEASUREMENT COMPANY Wyoming, MI THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION ACCREDITED LABORATORY A2LA has accredited INSPECTION MEASUREMENT COMPANY Wyoming, MI for technical competence in the field of Calibration The accreditation

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 QUALITY PLUS, INC. 170 Grove Street Chicopee, MA 01020 Mark J. Vickers Phone: 413 594 5529 CALIBRATION Valid

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. GREENSLADE & CO., INC Wenneca Avenue Fort Worth, TX Larry Borowski Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. GREENSLADE & CO., INC Wenneca Avenue Fort Worth, TX Larry Borowski Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 GREENSLADE & CO., INC. 2234 Wenneca Avenue Fort Worth, TX 76102 Larry Borowski Phone: 800 435 2657 CALIBRATION Valid To: October 31, 2018 Certificate Number:

More information

Rampura Tools.

Rampura Tools. +91-8048600379 Rampura Tools https://www.rampuratools.in/ We are one of the leading distributor, suppliers and traders of Measuring Instrument. Owing to their accurate measurement, sturdy construction,

More information

ITTC Recommended Procedures and Guidelines

ITTC Recommended Procedures and Guidelines and Guidelines Page 1 of 12 22 Table of Contents TUPURPOSE...UT2 TUWORK INSTRUCTION UT2 TU1 TU2 TU3 Introduction.2 Subject and Condition of Calibration...2 TU2.1UT TUSubject and Main Tools of Calibration...UT2

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 F. D. HURKA COMPANY 4731 Stockholm Court Charlotte, NC 28273 Charles Jenkins Phone: 704 552 0008 CALIBRATION Valid To: December 31,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ALPHAGAGE th Avenue Rockford, IL James Hoard Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ALPHAGAGE th Avenue Rockford, IL James Hoard Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALPHAGAGE 5245 27 th Avenue Rockford, IL 61109 James Hoard Phone: 815 391 6400 CALIBRATION Valid To: August 31, 2018 Certificate Number:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 JEM PRECISION 9615 56 Avenue NW Edmonton, Alberta T6E 0B2 Canada Robert Korthuis Phone: 780-440 1933 CALIBRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CLEVELAND SPECIALTY INSPECTION SERVICES, INC. 8562 East Avenue Mentor, OH 44060 James Popovic Phone: 440 974 1818 CALIBRATION Valid

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 LAKE SHORE INDUSTRIAL SERVICES, INC. 2230 Caughey Road Erie, PA 16506 Suzanne R. Zuba / James B. Cross Phone: 814 838 3539 CALIBRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 FRANK COX METROLOGY (Formerly CANADIAN CENTRAL GAUGE LABORATORY) 40 West Drive Brampton, Ontario, Canada L6T 3T6 Hilliard Cox Phone: 905 457 9190 CALIBRATION

More information

Height Master Page 343. Check Master Page 347. Calibration Tools Page 352

Height Master Page 343. Check Master Page 347. Calibration Tools Page 352 Calibration Instruments Height Master Page 343 Check Master Page 347 Calibration Tools Page 352 342 Digital Height Master Functions ZERO/ABS DATA/HOLD Auto Power OFF after 20 min. non use Low voltage alarm

More information

Engineering Metrology and Instrumentation

Engineering Metrology and Instrumentation 3 types Mechanical Cleaning Physically disturb contaminants Electrolytic Cleaning Abrasive bubbles aid in contaminant removal Chemical Cleaning Solution Saponification Emulsification Dispersion Aggregation

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 TRI-STATE INSTRUMENT SERVICE, INC. 3024 Wayne Trace Ft. Wayne, IN 46806 Lynn A. Stroble Phone: 260 456 4545 CALIBRATION Valid To: September

More information

TR CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF DIMENSIONAL METROLOGY

TR CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF DIMENSIONAL METROLOGY CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF DIMENSIONAL METROLOGY Approved By: Chief Executive Officer: Ron Josias Executive: Accreditation: Mpho Phaloane Revised By: Specialist Technical Committee

More information

BHARATHIDASAN ENGINEERING COLLEGE, NATTRAMPALLI. DEPARTMENT OF MECHANICAL ENGINEERING FAQ

BHARATHIDASAN ENGINEERING COLLEGE, NATTRAMPALLI. DEPARTMENT OF MECHANICAL ENGINEERING FAQ BHARATHIDASAN ENGINEERING COLLEGE, NATTRAMPALLI. DEPARTMENT OF MECHANICAL ENGINEERING FAQ Year/Sem : III/V Sub.Code/Title: ME6504- METROLOGY & MEASUREMENTS UNIT-I CONCEPT OF MEASUREMENT PART-A 1. Define

More information

ME3192 METROLOGY AND INSTRUMENTATION LABORATORY

ME3192 METROLOGY AND INSTRUMENTATION LABORATORY ME19 METROLOGY AND INSTRUMENTATION LABORATORY FORMAT FOR TABULAR COLUMNS - CYCLE 1 Batch 1 Expt 1 FIT BETWEEN NUT AND BOLTS Table 1: Order of specimens for different parameters Sl No Parameters Order 1

More information

台灣黑馬牌校正器類 CALIBRATOR METROLOGY

台灣黑馬牌校正器類 CALIBRATOR METROLOGY G1 G2 G3 Multi-functional Length Calibrator Calibration Function: All kind of caliper, micrometer, height gauge, dial indicator, bore gauge, and other measuring application. Model No. Calibration Range

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 FRANK COX METROLOGY (Formerly CANADIAN CENTRAL GAUGE LABORATORY) 40 West Drive Brampton, Ontario, Canada L6T 3T6 Hilliard Cox Phone: 905 457 9190 CALIBRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL Lasheila Hayes Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL Lasheila Hayes Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL 35096 Lasheila Hayes Phone: 205 505 0296 CALIBRATION Valid to: April 30, 2019 Certificate Number:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 MACHINIST TOOL REPAIR INC. 6484 Grafton Road Valley City, OH 44280 Susan Novak Phone: 330 483 3202 CALIBRATION Valid To: December 31,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS 38654 CONNIE FOSTER PHONE: 800 327 7727 CALIBRATION Valid To: August 31, 2019 Certificate Number:

More information

1 Measure various dimensions of component using Vernier caliper and dial type vernier caliper. d 3 d 1

1 Measure various dimensions of component using Vernier caliper and dial type vernier caliper. d 3 d 1 1 Measure various dimensions of component using Vernier caliper and dial type vernier caliper. 1. Note down the apparatus needed and draw component drawing and label parameters to measure. Vernier Caliper

More information

Metrology is science considering measurement

Metrology is science considering measurement Metrology is science considering measurement Categories: Scientific deals with organization and development of etalons and their conservation(highest level) Industrial deals with function of measuring

More information

FUNDAMENTALS OF DIMENSIONAL METROLOGY

FUNDAMENTALS OF DIMENSIONAL METROLOGY FUNDAMENTALS OF DIMENSIONAL METROLOGY CEJohansson Irvine, California SUB Gfittingen 7 215 940 806 Mesa Community College Mesa, Arizona CONTENTS ASUREMENT AND METROLOGY 1 1-1 Measurement as the Language

More information

Ackred. nr 1678 Kalibrering ISO/IEC 17025

Ackred. nr 1678 Kalibrering ISO/IEC 17025 Calibration Tvinnargatan 25 SE-507 30 Brämhult SWEDEN Phone: +4633 22 56 30 info@kalibrera.se www.kalibrera.se Ackred. nr 1678 Kalibrering ISO/IEC 17025 Our calibration lab is accredited by Swedac for:

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: C.V. (Calpromsa) (Hereinafter called the Organization)

More information

DHANALAKSHMI COLLEGE OF ENGINEERING. (Dr.VPR Nagar, Manimangalam, Tambaram) Chennai

DHANALAKSHMI COLLEGE OF ENGINEERING. (Dr.VPR Nagar, Manimangalam, Tambaram) Chennai DHANALAKSHMI COLLEGE OF ENGINEERING (Dr.VPR Nagar, Manimangalam, Tambaram) Chennai - 601 301 DEPARTMENT OF MECHANICAL ENGINEERING III YEAR V SEMESTER ME6504 ENGINEERING METROLOGY AND MEASUREMENTS QUESTION

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: AMC LABS S.A de C.V Av. México # 329 Col. Valle De

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation Wiltonstraat 25 3905 KW Veenendaal The Netherlands Location(s) where activities are performed under accreditation Head Office Location Abbreviation/ location Main Location Wiltonstraat 25 3905 KW Veenendaal

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 POLYMER TESTING INSTRUMENTS, INC. 74 Patton Ave. Asheville, NC 28801 Greg Skory Phone: 828 252 1326 CALIBRATION Valid To: June 30, 2017

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALABAMA SCALE & INSTRUMENT MARSHALL, INC. d.b.a. ASI Calibration Labs - Texas 1006 East End Blvd North Marshall, TX 75672 Lawson Hill

More information

LINEAR AND ANGULAR MEASUREMENTS

LINEAR AND ANGULAR MEASUREMENTS UNIT II LINEAR AND ANGULAR MEASUREMENTS UNIT-II 2. 1 CONTENTS 2.1 LINEAR MEASURING INSTRUMENTS 2.1.1 SCALES 2.1.2 CALIPERS 2.1.3 VERNIER CALIPERS 2.1.4 MICROMETERS 2.1.5 SLIP GAUGES 2.2 INTERFEROMETERS

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: AMC LABS S.A de C.V (Hereinafter called the Organization)

More information

2 - Machining Fundamentals Measurement. Manufacturing Processes - 2, IE-352 Ahmed M El-Sherbeeny, PhD Spring-2015

2 - Machining Fundamentals Measurement. Manufacturing Processes - 2, IE-352 Ahmed M El-Sherbeeny, PhD Spring-2015 2 - Machining Fundamentals Measurement Manufacturing Processes - 2, IE-352 Ahmed M El-Sherbeeny, PhD Spring-2015 Learning Objectives Measure to 1/64 (.5 mm) with a steel rule Reading an Inch-based Vernier

More information

DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK. Sub Code/Name: ME 1304/Engineering Metrology & Measurements Year/Sem :III/ V UNIT-I

DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK. Sub Code/Name: ME 1304/Engineering Metrology & Measurements Year/Sem :III/ V UNIT-I DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK Sub Code/Name: ME 1304/Engineering Metrology & Measurements Year/Sem :III/ V UNIT-I CONCEPT OF MEASUREMENT Part- A (2 Marks) 1. Differentiate between

More information

SIR C.R.REDDY COLLEGE OF ENGINEERING ELURU

SIR C.R.REDDY COLLEGE OF ENGINEERING ELURU SIR C.R.REDDY COLLEGE OF ENGINEERING ELURU-534007 METROLOGY LABORATORY MANUAL III/IV B.TECH (Mechanical): II SEMESTER DEPARTMENT OF MECHANICAL ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING METROLOGY

More information

Measurement devices. Kalevi Aaltonen, Aalto University

Measurement devices. Kalevi Aaltonen, Aalto University Measurement devices Kalevi Aaltonen, Aalto University Production engineering measurements, measuring uncertainty, measurement accuracy = statistical mathematical methods The pyramid of accuracy Material

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 POLYMER TESTING INSTRUMENTS, INC. 10 National Drive Fletcher, NC 28732 Larry Eisner Phone: 828 252 1326 CALIBRATION Valid To: June 30,

More information

MEASURING INSTRUMENTS

MEASURING INSTRUMENTS 2015 2016 MEASURING INSTRUMENTS CATALOG NO. 301 QUALIT Y INNOVATION SERVICE VALUE Our goal at INSIZE is to provide you, our customer, with quality innovative products at a reasonable price. INSIZE will

More information

UNIT-II LINEAR AND ANGULAR MEASUREMENTS

UNIT-II LINEAR AND ANGULAR MEASUREMENTS UNIT-II LINEAR AND ANGULAR MEASUREMENTS MEASUREMENT OF ENGINEERING COMPONENTS: v Measurement systems are mainly used in industries for quality control management. v Often quality control engineers are

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 FLORIDA METROLOGY, LLC 645 NW Enterprise Dr. Port St. Lucie FL 34986 Ron Kupper Phone: (772)212-7158 CALIBRATION Valid To: October 31,

More information

Measuring methods. Measuring tools. Measuring methods. Measuring tools. Measuring methods. Measuring tools. Measuring methods. 5. Smoothness testing

Measuring methods. Measuring tools. Measuring methods. Measuring tools. Measuring methods. Measuring tools. Measuring methods. 5. Smoothness testing 1. Parallelism testing / Height testing Dial gauge and Dial indicator 2. Fix the measuring tools on the actuator s slider. 2. Absolute straightness accuracy testing Laser interferometer detection 2. Fix

More information

Unit III Introduction sine bar Sine bar Working principle of sine bar

Unit III Introduction sine bar Sine bar Working principle of sine bar Unit III Introduction Angular measurement is an important element in measuring. It involves the measurement of angles of tapers and similar surfaces. In angular measurements, two types of angle measuring

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Black Granite Surface Plates

Black Granite Surface Plates Black Granite Surface Plates Surface Plates SURFACE ACCURACY GGG-P-463c. Harder then steel. Retains accuracy for years. Guaranteed repeat reading. unilateral accuracy of plate. Does not rust or corrode.

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:. (Hereinafter called the Organization) and hereby

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:. Av. Rio Consulado # 2614, Col. San Juan de Aragón

More information

Course: Technology II Training course topic: Metrology

Course: Technology II Training course topic: Metrology Department of machining, process planning and metrology ver.2017-01 Following problems and tasks will be solved during the first two weeks of the training courses of Technology II. Detailed information

More information

Sale 4, Inspection Equipment

Sale 4, Inspection Equipment Major Automotive Parts Manufacturer Sale 4, Inspection Equipment (Ends: 2019-02-14 14:00:00.0) Online Auction Of Test & Inspection Equipment. 750 Romer RA_7525SI Co-ordinate Measuring Arm Romer RA_7525SI

More information

Wenzhou Tripod Instrument Manufacturing Co., Ltd.

Wenzhou Tripod Instrument Manufacturing Co., Ltd. Wenzhou Tripod Instrument Manufacturing Co., Ltd. Website: http://aliyiqi.en.alibaba.com http://www.wzydyq.com/english/ Phone: 86-577-57572515 57572515 Fax: 86-577-57572516 57572516 E-mail: aliyiqi@gmail.com

More information

The Program. Wear measurement Page 5. Inspection of parts Page 6. Online certificate Page 7. DKD-calibration Page 8. Deviation analysis Page 11

The Program. Wear measurement Page 5. Inspection of parts Page 6. Online certificate Page 7. DKD-calibration Page 8. Deviation analysis Page 11 The Program Wear measurement Page 5 Inspection of parts Page 6 Online certificate Page 7 DKD-calibration Page 8 u PM -certificate Page 10 Deviation analysis Page 11 Quality manager Thomas Peter 09187/

More information

E.G.S. PILLAY ENGINEERING COLLEGE Nagapattinam DEPARTMENT OF MECHANICAL ENGINEERING V SEMESTER REGULATION 2013 CHENNAI

E.G.S. PILLAY ENGINEERING COLLEGE Nagapattinam DEPARTMENT OF MECHANICAL ENGINEERING V SEMESTER REGULATION 2013 CHENNAI E.G.S. PILLAY ENGINEERING COLLEGE Nagapattinam 611002. DEPARTMENT OF MECHANICAL ENGINEERING V SEMESTER REGULATION 2013 CHENNAI ME 6513- METROLOGY AND MEASUREMENTS LAB LAB MANUAL Prepared & Compiled by

More information

Refer to page E-6 for details. Refer to page E-31 for details. Digital Height Master. Refer to page E-35 for details. High Precision Square

Refer to page E-6 for details. Refer to page E-31 for details. Digital Height Master. Refer to page E-35 for details. High Precision Square NewProducts Ultra Low xpansion Ceramic Gauge (ZRO CRA Block) Refer to page -6 for details. Gauge Block Comparator GBCD-00A Refer to page -3 for details. Digital Height Master Refer to page -35 for details.

More information

CEEN 3320 Behavior & Properties of Engineering Materials Laboratory Experiment No. 1 Measurement Techniques

CEEN 3320 Behavior & Properties of Engineering Materials Laboratory Experiment No. 1 Measurement Techniques Laboratory Experiment No. 1 Measurement Techniques Engineers rely on data from a wide variety of sources to design the things that make up our physical world and to ensure compliance with established specifications.

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: CONMED LABMET S. de R.L. de C.V. (Hereinafter called

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

DISCONTINUED PRECISION MEASURING FOWLER CALIPERS 1 - VERNIER CALIPERS 4 - ELECTRONIC CALIPERS

DISCONTINUED PRECISION MEASURING FOWLER CALIPERS 1 - VERNIER CALIPERS 4 - ELECTRONIC CALIPERS FOWLER CALIPERS 1 - VERNIER CALIPERS 4 - ELECTRONIC CALIPERS 52-058-016 Fine quality vernier calipers are constructed of stainless steel. 52-057-004 offers 3-way measurement to accuracy. 52-058-XXX series

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 QAL-TEK ASSOCIATES 3998 Commerce Circle Idaho Falls, ID 83401 Travis Snowder Phone: 208 523 5557 CALIBRATION Valid To: January 31, 2019

More information

Displacement and Dimension Measurement. Measuring Devices The Interferometer The Differential Transformer

Displacement and Dimension Measurement. Measuring Devices The Interferometer The Differential Transformer Displacement and Dimension Measurement Measuring Devices The Interferometer The Differential Transformer Low-Resolution Devices(0.25mm) Steel rule used directly or with assistance Calipers Dividers Surface

More information

TESA MICROMASTER Electronic Micrometers with Digital Display

TESA MICROMASTER Electronic Micrometers with Digital Display TESA MICROMASTER Electronic Micrometers with Digital Display DIN 86 T1 0,001 0.00005 in Metric/Inch conversion 100 : Ø 6,5 > 100 : Ø 8 With patented TESA capa µ system Measuring span of 0 or 25. Large

More information

บร การสอบเท ยบ และทดสอบเคร องม อว ด

บร การสอบเท ยบ และทดสอบเคร องม อว ด NSCTISITIS70 CALIBRATION 0008 บร การสอบเท ยบ และทดสอบเคร องม อว ด http://www.tpa.or.th/ce/ สมาคมส งเสร มเทคโนโลย (ไทยญ ป น) Technology Promotion Association (ThailandJapan) Accredited Laboratory ISO/IEC

More information

Instruction for use Plunger Probes M FB and M78-Plus

Instruction for use Plunger Probes M FB and M78-Plus Instruction for use Plunger Probes M5678-78FB and M78-Plus Rev 3 (10/2012) DIATEST Plunger Probe M5678-68FB Self-centering interior measuring gauge for bore diameter from 19,5 to 330 mm Design A plunger

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Guadalupe, Nuevo León, México. C.P. 67110 (Hereinafter

More information

Read the following BEFORE getting started:

Read the following BEFORE getting started: BASIC MEASUREMENTS Read the following BEFORE getting started: Ruler: A ruler, or rule, is an instrument used in geometry, technical drawing and engineering/ building to measure distances and/or to rule

More information

Trimos LABCONCEPT Universal Length Measuring Instrument

Trimos LABCONCEPT Universal Length Measuring Instrument 426 Trimos LABCONCEPT Universal Length Measuring Instrument The Fowler/Trimos LABCONCEPT Universal Length Measurement System combines the ultimate in accuracy, performance, range and simplicity in an easy

More information

Measurement of basic constants: length, weight and time

Measurement of basic constants: length, weight and time Measurement of basic constants: length, weight and time TEP Related topics Length, diameter, inside diameter thickness, curvature, vernier, weight resolution, time measurement. Principle Caliper gauges,

More information

TRACEABILITY STRATEGIES FOR THE CALIBRATION OF GEAR AND SPLINE ARTEFACTS

TRACEABILITY STRATEGIES FOR THE CALIBRATION OF GEAR AND SPLINE ARTEFACTS TRACEABILITY STRATEGIES FOR THE CALIBRATION OF GEAR AND SPLINE ARTEFACTS W. Beyer and W. Pahl Physikalisch-Technische Bundesanstalt (PTB) 38116 Braunschweig, Germany Abstract: In accordance with ISO 17025,

More information

PARTS MANUAL 2 INCH CHIPPER/SHREDDER. SC cc SUBARU

PARTS MANUAL 2 INCH CHIPPER/SHREDDER.   SC cc SUBARU www.bearcatproducts.com 2 INCH CHIPPER/SHREDDER SC2170 170cc SUBARU PARTS MANUAL PN: 1641-00 Rev. 0011 Companion to 1509-00 Range: D01688 - Current Before You Begin DEAR ECHO BEAR CAT CUSTOMER Thank you

More information

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere Lecture 32 Introduction To Comparators, Mechanical Comparators (Refer Slide Time: 00:15) I welcome you

More information

MECHANICS LAB AM 317 EXP 4 TORSION OF CIRCULAR RODS

MECHANICS LAB AM 317 EXP 4 TORSION OF CIRCULAR RODS MECHANICS LAB AM 317 EXP 4 TORSION OF CIRCULAR RODS I. OBJECTIVES I.1 To become familiar with torsion tests of rods with solid circular cross sections. I.2 To observe the relation between shear stress

More information

Dhanalakshmi College of Engineering

Dhanalakshmi College of Engineering Dhanalakshmi College of Engineering Manimangalam, Tambaram, Chennai 601 301 DEPARTMENT OF MECHANICAL ENGINEERING ME6513 METROLOGY AND MEASUREMENTS LABORATORY V SEMESTER - R 2013 LABORATORY MANUAL Name

More information

Engineering Metrology

Engineering Metrology Albaha University Faculty of Engineering Mechanical Engineering Department Engineering Metrology Lecture 04: Angular Measurements Ossama Abouelatta o_abouelatta@yahoo.com Mechanical Engineering Department

More information

Development of Laser Thickness Gauge in Steel Plate Shearing Line

Development of Laser Thickness Gauge in Steel Plate Shearing Line JFE TECHNICAL REPORT No. 21 (Mar. 2016) Development of Laser Thickness Gauge in Steel Plate Shearing Line TEZUKA Koichi *1 Abstract: JFE Steel has developed a laser thickness gauge for the purpose of guaranteeing

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

COMMON MISTAKES IN DIMENSIONAL CALIBRATION METHODS

COMMON MISTAKES IN DIMENSIONAL CALIBRATION METHODS COMMON MISTAKES IN DIMENSIONAL CALIBRATION METHODS AN EDUCATIONAL PRESENTATION FROM THE LEADING MANUFACTURER OF METROLOGY INSTRUMENTS EDUCATION Bulletin EDU-14002A-H No. 2183 Mitutoyo Institute of Metrology

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ARCONIC POWER AND PROPULSION RESEARCH CENTER 1500 S. Warner St. Whitehall, MI 49461-1895 Michelle McDonald Phone: 231 894 7586 CALIBRATION

More information

Introduction. Earlier. To Scales. We talked about. L Dimensions

Introduction. Earlier. To Scales. We talked about. L Dimensions 1 Introduction To Scales Introduction 2 Earlier We talked about Dimensions T Parts of the dimension object OExtension lines ODimension line OArrowheads ONumeric value T ocation of the numeric value Earlier

More information

Laboratory Manual Physics_1. Index of refraction for solids

Laboratory Manual Physics_1. Index of refraction for solids AGH University of Science and Technology in Cracow Department of Electronics Laboratory Manual Physics_ Title: 009 r. Index of refraction for solids Experiment No. 9 . Goal To determine the index of refraction

More information

Electronic Indicators / Dial Gauges / Dial Test Indicators (Lever-Type)

Electronic Indicators / Dial Gauges / Dial Test Indicators (Lever-Type) Electronic Indicators/Dial Gauges/Dial Test Indicators (Lever-Type) Electronic Indicators / Dial Gauges / Dial Test Indicators (Lever-Type) E-1 DIN 2270 NF E 11-053 TESATAST Dial Test Indicators (Lever-Type)

More information

mag 6 & mag 7 magnifiers

mag 6 & mag 7 magnifiers mag 6 & mag 7 magnifiers MAG 7 inspection magnifier - x4 magnification with reticle holder Ordering Information cat. ref: MAG7 order code: 50E02014 cat. ref: MAG7TR (with torch) order code: 50E02016 magnification:

More information

Perry Johnson Laboratory Accreditation, Inc. Calibration Scopes of Accreditation

Perry Johnson Laboratory Accreditation, Inc. Calibration Scopes of Accreditation Perry Johnson Laboratory Accreditation, Inc. Calibration Scopes of Accreditation PL-4 Calibration Scopes Revised: 2/17 Page 1 of 19 1.0 INTRODUCTION 1.1 This policy has been developed by PJLA and its technical

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 AMERICAN INSTRUMENT CORPORATION Crossroads Centre 702 Rose Drive Hartland, WI 53029 Jeff Quinn Phone: 262 367 4409 CALIBRATION Valid

More information

Auto collimator. Introduction. Objectives: Apparatus: Theory:

Auto collimator. Introduction. Objectives: Apparatus: Theory: Auto collimator Introduction An autocollimator is an optical instrument that is used to measure small angles with very high sensitivity. As such, the autocollimator has a wide variety of applications including

More information

6. Tolerances are specified (a) to obtain desired fits (b) because it is not possible to manufac ture a size exactly (c) to obtain high accuracy

6. Tolerances are specified (a) to obtain desired fits (b) because it is not possible to manufac ture a size exactly (c) to obtain high accuracy 1. Who made the following classic statement. "When you can measure what you are speaking about and express it in numbers, you know something about it, and when you can't express it in numbers, your knowledge,

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Chapter 11 Design of Low Friction Surfaces

Chapter 11 Design of Low Friction Surfaces Chapter 11 Design of Low Friction Surfaces 1 Design of Low Friction Surfaces (no lubricant allowed) Consider the task of creating low friction surfaces for sliding applications. FR 1 = Support the normal

More information

SL27C SL32C. ScreenLine. Technical Catalogue. english. double-glazed unit 27 mm 32 mm

SL27C SL32C. ScreenLine. Technical Catalogue. english. double-glazed unit 27 mm 32 mm VENETIAN SL27C SL32C BLIND english Technical Catalogue double-glazed unit 27 mm 32 mm dimensions technical specification SL27C SL32C System C C SL27C VENETIAN SL32C BLIND The venetian blinds SL27C and

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Asesoría Industrial en Mantenimiento y Calibración

More information

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-K-15133-02-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 24.01.2018 to 23.01.2023 Holder of certificate: Hexagon

More information

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T Translated English of Chinese Standard: GB/T4161-2007 www.chinesestandard.net Buy True-PDF Auto-delivery. Sales@ChineseStandard.net ICS 77.040.10 NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA GB

More information

Magnetic Field Measurement System For Cryogenic Permanent Magnet Undulator At SSRF

Magnetic Field Measurement System For Cryogenic Permanent Magnet Undulator At SSRF Magnetic Field Measurement System For Cryogenic Permanent Magnet Undulator At SSRF Hongfei Wang, Jingmin Zhang,Wei Zhang, Qiaogen Zhou Shanghai Institute of Applied Physics, P.O.Box 800-204, Shanghai 201800,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ALLOMETRICS, INC Bayport Blvd. Seabrook, TX Terry Baldwin Phone: CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ALLOMETRICS, INC Bayport Blvd. Seabrook, TX Terry Baldwin Phone: CALIBRATION SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ALLOMETRICS, INC. 2500 Bayport Blvd. Seabrook, TX 77586 Terry Baldwin Phone: 281 474 3329 CALIBRATION Valid To: April 30, 2019 Certificate Number: 2039.01 In

More information

Science. Circular Motion. Atomic Structure and Nuclear Chemistry. Kinematics; Motion in One and Two Dimensions

Science. Circular Motion. Atomic Structure and Nuclear Chemistry. Kinematics; Motion in One and Two Dimensions Inquiry -P-1.1 -P-1.2 -P-1.3 -P-1.4 -P-1.5 -P-1.6 -P-1.7 -P-1.8 -P-1.9 -P-2.1 -P-1.1 -P-2.1 -P-2.2 -P-2.3 Circular Motion Use appropriate safety procedures when conducting investigations. Use appropriate

More information

High Accuracy CMM Measurements at NIST

High Accuracy CMM Measurements at NIST High Accuracy CMM Measurements at NIST by John Stoup National Institute of Standards and Technology, USA 2007 CMM Users Meeting - Mexico October 22, 2007 Today s Discussion We will describe the equipment

More information

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore

DN 1/4 to 4 Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1) Specifications : Anti blow-out stem PTFE packing Full bore Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 4" Male, Female BSP - 10 C + 120 C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore Materials

More information

W W W. T Y G. C O M. M X

W W W. T Y G. C O M. M X T O O L I N G E Q U I P M E N T S H A R M E N I N G S E R V I C E R E A M E R S D R I L L S E N D M I L L S D R I V E S S P I N D L E R E P A I R S E R V I C E B A L L S C R E W S E R V O S B A N D S A

More information

Siddharth Institute of Engineering & Technology

Siddharth Institute of Engineering & Technology SIDDHARTH INSTITUTE OF ENGINEERING & TECHNOLOGY :: PUTTUR (AUTONOMOUS) (Approved by AICTE, New Delhi & Affiliated to JNTUA, Anantapuramu) (Accredited by NBA & Accredited by NAAC with A Grade) (An ISO 9001:2008

More information

Level-Type Dial Indicator

Level-Type Dial Indicator Level-Type Dial Indicator Feature Swiss style precision gear module design, precision display, aluminum or steel housing, ensuring reliability and durability. Produced and calibrated according to German

More information