1 IT Series Infrared thermometer Using manual Wuhan Dikai Optic-electronic Technology Co., ltd

2 Before using the thermometer, please read the manual carefully, for the purpose of better exert its function and prolong service life. Please keep the manual carefully for consult later. If appear these problems: Appearing the abnormality, please turn off the power, and contact us in time. That take apart yourself will not have after service and won t have servicing for free If this manual altered, forgive us won t inform you

3 Catalogue 1 Summary 2 Technology parameter 3 Figure structure 4 Model naming and selection 5 Usages 6 Maintenance and molar assurance 7 Notice 8 Selection of infrared thermometer Attach: the emissivity list of familiar materials on temperature measuring

4 1 Summary IT series infrared thermometer has the same optical axis on the measurement and collimation. For satisfying the different requirements of customers, the meter can be segmented between 300 and 3000 discretionally. Because of using SMT on the part of circuit transformation and MCU on the part of data processing, the accuracy and Repeatability can be guarantee better. Especially, the meter is suit to locomotors objects, electriferous conductors vacuum environment or other objects that have special request to be non-contact measured. The measure is without influence to the temperature field. The product can be applied to foundry, powder metallurgy, steel rolling, power supply, chemical industry, glass, ceramic production, heat treatment, intermediate/high frequency induction heating, wire production, sinter, hot-pressing sinter, jointing industry and so on. 2 Technology parameter Measuring range 300 ~3000 (subsection) Measuring accuracy ±0.5%,±0.2%(Reading) Measuring distance 0.2m~5m Mini object φ2mm(298mm),φ0.5mm (80mm) Distance coefficient 145:1,160:1 Repeatability ±0.2 Response time <10 ms Resolution 0.5 Sighting system Laser sighting Sensing head size φ50 100mm Emissivity 1.0,0.9,0.8,0.7 (IT-6) 0.10~1.00 (IT-8) Output 0~5V,4~20mA Power ±12VDC Weight 0.5kg Working environment 0 ~60,Humidity<90% Installation 1/4 inch bolt Communication RS485(IT-8)

5 3 Figure structure IT-6 unit:mm IT-6 Back cover : IT-8 unit:mm

6 IT-8 Back cover: Key-press definition: SET key: using for parameter setting, on the state of waiting or working, press the key for 5 sec, enter the state of parameter setting, on the course of parameter setting, press the key for 5 sec, back to the state of temperature displaying. Without any action for 15 min, the display will shut down automatically. On the state of blank screen, pressing the key can activate the temperature display. key:on the state of parameter, using the key for moving radix point, meanwhile, the position of radix point effect. key: Using for program the position of selected. Parameter setting manual table Parameter Meaning Range Default E1 Emissivity ~ E2 Emissivity ~1.00(ITW only) 1.00 AHd Peak value 0~120 sec 0 keeping time defd Difference value 0~120 sec 0 keeping time CoEF Filter coefficient 0~20 0 Ad Interface address 1~100 1 rad Measuring mode 0:Continious measuring;1:peak measuring ;2:Difference measuring 0 4 Model naming and selection (1)Model naming IT X X X X English Letter output sorts V:0~5V;I:4~20mA Number Temperature range 1: 400 ~1200 Number Accuracy level 1:0.5 level Number Series code 6: no laser collimation; 8: laser collimation English abbreviate(infrared-thermometer)

7 express:lentoid infrared thermometer Example:IT 612V means:no laser collimation 0.5 level 800 ~2500 output 0~5V lentoid infrared thermometer (2)Selective list Model Manual Remark IT- Infrared English abbreviate 6 Ordinary Sort Emissivity can be adjusted 8 Enhanced peak value can be kept 0 1 level(fs%1) Tiptop 0.2 level(fs% 0.2) Precision level (FS% 0.5) 0 300~ ~ ~1400 Can be disjoined at will Range( ) 3 600~1400 between 300~ ~ ~ ~3000 V 0~5VDC Output I 4~20mA Communication c RS485/RS232 interface 5 Usages (1) Installation:fixing by the 1/4 inch bolt (2) Derivative wire defined: Derivative wire Link Derivative defined spinouts wire color Simulate output RS485 1 Red +12V +12V 2 Blue -12V -12V 3 Black Terra terra 4 Yellow Output A 5 Green B Shielded wire link to the shell of the meter, or can be linked to the earth of the equipment. When it is unable to link, can be linked to the terra of power

8 (3)Output selection Simulate signal output:0~5vdc 4~20mA RS485(IT-8) Serial interface s usage: The sending mode of serial interface is simplex system, speed: 9600 baud When process controlling or long distance communicating,rs485 serial interface It need the RS485 RS232 conversion machine when need to communicate to calculator 6 Maintenance and quality guarantee (1)In the normal conditions, the thermometer need not special maintenance, keep off dampness please. And clean the lens surface of the thermometer regularly (using lens paper or soft cloth, wipe carefully and do not hurt the lens); (2) When the thermometer is not used, cut off the power and cover the lens saving in the dry and clean circumstances (3) The malfunction causing by quality problem of products,free repair within 12 month after leave the factory Repair lifetime 7 Notices (1) When setup the thermometer,the light axis must be vertical to the object, otherwise will causing measuring error (2) The effective distance of laser aim is no more than0.3m (3) The thermometer has good response speed and good sensitivity, when the heat source (object)is instable,it s normal that the display meter of thermometer will move up and down follow; (4) The thermometer needs fixed, avoiding vibration 8 Selection of infrared thermometer Confirming the range of measuring: The range of measuring is one of the thermometer s most important capability quota, every type of thermometer has each special range of temperature measuring. Narrower the thermometer s range is, the monitor temperature output signal resolution is higher, and the reliability is resolved easily. That the range is too wide will lower the accuracy of temperature measuring. Size of object: According to the principle of infrared thermometer, it s divided into homochrome infrared thermometer and bicolor infrared thermometer When using homochrome infrared thermometer, it s better that the area of object exceed the sight-field by 50% And to the small and moving or vibrant object, bicolor infrared thermometer is the best choice.

9 Distance coefficient(optical resolution):distance coefficient is the ratio of D (the distance between head and the object) and the diameter of the object. If the distance to the object is far, and the object is small, you should choose the high distance coefficient thermometer, on the other hand, you should choose low distance coefficient thermometer. Confirming response time::response time express the response speed that the infrared thermometer responses to the temperature being measured, defined as the time needed that arrive 95% of the last reading power It has relations with photo-electric detector, signal process circuit and the time constant of display system If the speed of moving object is very quick and measuring the object that heated quickly, you should choose the high-speed response infrared thermometer, otherwise, it won t achieve the enough signal response speed and will lower the measuring accuracy. But not all of applications need quick response infrared thermometer. To the quiescent object or the object that on the course of heat has heat inertia, the response time can be loosen. Therefore, the infrared thermometer s selection must be adapted to the state of the object. Confirming circumstance:the circumstance of the thermometer will affect the measuring result a lot., so the problem should be considered and be solved properly, otherwise, this will affect the accuracy of thermometer even damage the thermometer On the conditions of high temperature, existing dust, smoke and steam, you should choose the accessories supplied by factory such as protect cover, water-cool, air-cool, air-cool system, air-blow etc These accessories can solve circumstance influence effectively and protect the thermometer, realizing temperature measuring exactly. When choosing accessory, you should request standard service as far as possible to reduce the cost of setup. It would be the best to choose bicolor infrared thermometer on the conditions of smoke, dust or other situation that grain will lower the power of measuring signal. Also, on the conditions of noisy, electromagnetic field, shaking or the circumstance that difficult to be closed or other bad conditions, bicolor infrared thermometer is the best. On the conditions of bad and complex, choosing the system that the thermometer head and the monitor is divided is convenience to setup and equip. You should choose the signal modality that matching the control equipment actual Emissivity of material(emissivity):when there are many kinds of material measured and their emissivity is different, it s better to choose the infrared thermometer that the emissivity is adjustable.

10 Attach: the emissivity list of familiar materials on temperature measuring Material Emissivity Material Emissivity polished 0.04~ 0.06 Asbestos 0.95 Aluminum Anode oxidized 0.55 Asphaltum 0.95 Oxidized 0.11~ 0.70~ Paper Polished 0.02~ 0.05 Concrete 0.92 Brass Unoxidized 0.20 Water icewater 0.95 Oxidized 0.6~0.88 Gypsum 0.80~ 0.90 Polished 0.10 Skin 0.98 board Steel 0.40~ Slab Carbon Nonmetal 0.80~ Metal Tungsten 0.05 Paint 0.98 Electroplate 0.90~ 0.05 Soil polished 0.98 Nickel Electroplate unpolished 0.11 Rubber 0.95 Oxidized 0.30~ 0.50 Ceramic 0.93 Polished 0.05~ 0.07 Wood 0.93 plumbum Roughened 0.40 Ice 0.98 Oxidized 0.30~ 0.60 Fiberboard 0.95 Unoxidized 0.05 Lampblack 0.96 Zinc Galvanized iron plate 0.25 Sand 0.90

GS-IR 8816 Series Infrared Thermometer

GS-IR 8816 Series Infrared Thermometer GS-IR 8816 Series Infrared Thermometer Objects having temperatures above absolute zero radiate infrared energy all the time. This infrared energy has a certain functional relations with the surface temperature

More information

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700 Non-Contact Infrared Temperature Sensor/Transmitter Temperature Range: 500~1700 IR 80-H C-910C, Bupyeong Woolim Lion s Valley, #425, Cheongcheon-Dong, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507 FAX:

More information

INFRARED THERMOMETER Model : TM-959

INFRARED THERMOMETER Model : TM-959 LED target light, Emissivity adjustment INFRARED THERMOMETER Model : TM-959 Your purchase of this I N F R A R E D THERMOMETER marks a step forward for you into the field of precision measurement. Although

More information

IR 40. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 0~1000

IR 40. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 0~1000 Non-Contact Infrared Temperature Sensor/Transmitter Temperature Range: 0~1000 IR 40 C-910C, Bupyeong Woolim Lion s Valley, #425, Cheongcheon-Dong, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507 FAX:

More information

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration User Manual Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio with NIST-Traceable Calibration Model 20250-09 THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense

More information

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model 35625-15 THE STANDARD IN PRECISION MEASUREMENT 1 DGMAN_35625-15_(ENG_FR).indd 1 7/8/2014

More information

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual WD1063 Rev B Revised 02/23/15 Wahl Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131

More information

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL TABLE OF CONTENTS TITLE PAGE INTRODUCTION...1. SAFETY INFORMATION...2. FEATURES...4. SPECIFICATIONS...4.

More information

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com Model ST-616CT Infrared Thermo-Hygrometer Instruction Manual reedinstruments com Table of Contents Safety... 2 Features... 3 Specifications...4-5 Instrument Description...6-7 Operating Instructions...8-10

More information

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual HL-800K Infrared Laser Thermometer -50 C to +800 C (13:1 ratio) User Manual TABLE OF CONTENTS INTRODUCTION... 3 FEATURES... 3 WIDE APPLICATION RANGE... 3 SAFETY... 3 DISTANCE & SPOT SIZE... 4 SPECIFICATIONS...

More information

Introduction Cautions

Introduction Cautions 1 Introduction Compact, rugged and easy to use. Just aim and push the button, read current surface temperatures in less than a second. Safely measure surface temperatures of hot, hazardous or hard-to-reach

More information

INFRARED THERMOMETER TM0819

INFRARED THERMOMETER TM0819 INFRARED THERMOMETER Instruction Manual HORMES LIMITED cs@perfectprime.com G/F UNIT 3, 61 GLENTHORNE ROAD, LONDON W6 0LJ UNITED KINGDOM +44 203 7695377 Retailer Email Address Telephone P.1 CONTENTS 1.

More information

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual Gun-Type Professional Infrared Thermometer MODEL: ST 653 Instruction Manual Gun-Type Professional Infrared Thermometer Instruction Manual Table Content 1.Product Introduction 1-1 Features 1-2 Applications

More information

Instruction Manual SEFRAM Thermal Camera

Instruction Manual SEFRAM Thermal Camera Instruction Manual SEFRAM 9830 Thermal Camera EN Introduction The SEFRAM 9830 Thermal Camera (the Product) can display thermal gradient, temperature readings, map and measure the infrared energy radiated

More information

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer INSTRUCTION MANUAL Thermometer DUAL-LASER TARGETING 12:1 DISTANCE- TO-SPOT RATIO AUTO-SCAN MAX/MIN/AVG/DIFF HIGH/LOW ALARM BACKLIT DISPLAY AUTO POWER-OFF ADJUSTABLE EMISSIVITY IR5 2m -22 752 F (-30 400

More information

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

MN-ISO-2000FN-E.   ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL MN-ISO-2000FN-E www.insize.com ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL V0 Place the probe on the zero plate and wait until beep. Lift the probe for minimal 5 cm off the zero plate and wait

More information

Infrared Thermometer Model: and

Infrared Thermometer Model: and Infrared Thermometer Model: 72-820 and 72-823 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. Please operate according to this manual,

More information

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting Whitepaper_ WP_T_Non-Contacting_Temperature_Measurement ABB temperature measurement Radiation thermometry Measurement made easy Process temperature measurement practice--non-contacting By Gary Freeman,

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

Infrared Thermosensor ES1C

Infrared Thermosensor ES1C Infrared Thermosensor ES1C Achieve Superior Environmental Resistance and a Wide Measurement Range of 0 to 400 C. Flexible placement with slim cylindrical shape and long focus with a distance of 500 mm

More information

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect Microscanner D-Series The Only Certified Accurate Surface Instruments in the World A MUST FOR ISO 9001 ISO 9002 ISO 9003 TRACEABILITY PROGRAMS Common Surface Measurement Errors D501 and D501-RS Microscanner

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

Red and Green Dot Sight FF26002 USER MANUAL

Red and Green Dot Sight FF26002 USER MANUAL Red and Green Dot Sight FF26002 USER MANUAL The Firefield brand has recently launched with products designed to maximize every intense moment. Originally designed for consumers who need products to hold

More information

INSTRUCTION MANUAL DTH Fax: (503)

INSTRUCTION MANUAL DTH Fax: (503) INSTRUCTION MANUAL DTH51 1-800-547-5740 Fax: (503) 643-6322 www.ueiautomotive.com email: info@ueitest.com Introduction C o n t rols and Indicators The DTH51 gives you quick access to the information you

More information

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909) HS515G-M PARALOW Circle Dot Sight User's Manual Multi Reticle Holosun Technologies Inc. Phone: (909) 594-2888 Fax: (909) 598-4888 E-mail: info@holosun.com COLOR www.holosun.com PARALOW HS515G-M PARALOW

More information

Owner's Manual. for AUTOMATIC LEVEL. NBL Series. FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free:

Owner's Manual. for AUTOMATIC LEVEL. NBL Series. FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free: Owner's Manual for AUTOMATIC LEVEL NBL Series FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free: 1-888-247-1960 1 1. CONTENTS 2. Nomenclature page 3 3. Care and Maintenance page 4 4. Using your Instrument

More information

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch USER MANUAL REFLEX SIGHT Ultra Shot Z Series English / Francais / Español / Deutsch ABOUT SIGHTMARK Sightmark offers a wide range of products that include red dot scopes, reflex sights, rangefinders, riflescopes,

More information

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016 APPLICATIONS Moisture monitoring of air or gas (SF6) Suitable for indoor or outdoor Industrial, medical or aerospace fields HIGHLIGHTS High voltage circuit breakers commonly used for distribution and transmission

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct

More information

1. Electrostatic Lab [1]

1. Electrostatic Lab [1] 1. Electrostatic Lab [1] Purpose: To determine the charge and charge distribution on insulators charged by the triboelectric effects and conductors charged by an Electrostatic Voltage Source. Equipment:

More information

Operating instructions Infrared temperature sensor TW20xx TW21xx

Operating instructions Infrared temperature sensor TW20xx TW21xx Operating instructions Infrared temperature sensor TW20xx TW21xx UK 80270318 / 00 10 / 2017 F C Contents 1 Preliminary note...4 1.1 Key to the symbols...4 2 Safety instructions...4 3 Functions and features...4

More information

CHARACTER TYPE LCD MODULE PVC160101PTN03 PRODUCT SPECIFICATIONS

CHARACTER TYPE LCD MODULE PVC160101PTN03 PRODUCT SPECIFICATIONS CHARACTER TYPE LCD MODULE PVC160101PTN03 PRODUCT SPECIFICATIONS CAUTION The product described by these specifications is designed to be used with ordinary electronic equipment or devices, such as audio/video

More information

MODEL NAME : LLDMWW0-15K*0*A

MODEL NAME : LLDMWW0-15K*0*A Eagle Eye (Outdoor LED Module) Application Note MODEL NAME : LLDMWW0-15K*0*A RoHS Compliant HALOGEN FREE (30)-4022 1 / 16 CONTENTS 1. Product Description 3/16 2. Specifications 2.1. Chromaticity Bins for

More information

Reflow Soldering Processes Development Using Infrared Thermography

Reflow Soldering Processes Development Using Infrared Thermography Reflow Soldering Processes Development Using Infrared Thermography Petko Mashkov, Tamara Pencheva, and Berkant Gyoch Physics Department, University of Rousse, Bulgaria tgp@ru.acad.bg Abstract: Investigation

More information

Model 791 Calibration Plate for Tiltmeters and Inclinometers

Model 791 Calibration Plate for Tiltmeters and Inclinometers User s Manual Model 791 Calibration Plate for Tiltmeters and Inclinometers Serial No. Baseline, L Date measured By mm Introduction The Model 791 Calibration Plate is designed for calibrating any tiltmeter

More information

Second Focal Plane MOA

Second Focal Plane MOA Second Focal Plane MOA Product Manual Product Manual The Strike Eagle Riflescope The need for high-performance, precision optics is the driving force behind all we do. And your Stike Eagle is a prime example

More information

Technical Data Sheet. Pb Free. Specification GR101 SSC. Customer. Rev. 02 January 서식번호 : SSC- QP (Rev.0.

Technical Data Sheet. Pb Free. Specification GR101 SSC. Customer. Rev. 02 January 서식번호 : SSC- QP (Rev.0. Specification GR101 Pb Free Drawn SSC Approval Customer Approval [ Contents ] 1. Description 2. Absolute maximum ratings 3. Electro-Optical characteristics 4. Characteristic diagrams 5. Reliability result

More information

INTRODUCTION TO ENGINEERING SURVEYING (CE 1305)

INTRODUCTION TO ENGINEERING SURVEYING (CE 1305) INTRODUCTION TO ENGINEERING SURVEYING (CE 1305) Linear Measurements Sr Dr. Tan Liat Choon Email: tanliatchoon@gmail.com Mobile: 016-4975551 1 EDM, TOTAL STATION, PRISM AND POLE 2 ELECTROMAGNETIC DISTANCE

More information

Ground Penetrating Radar & By Mike Kelty Western Technologies Inc.

Ground Penetrating Radar & By Mike Kelty Western Technologies Inc. Ground Penetrating Radar & Thermorgraphy By Mike Kelty Western Technologies Inc. Overview Types of Locating Methods/Equipment How GPR Works GPR Applications How Thermography Works Thermography Applications

More information

ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook

ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook Isothermal Technology Limited, Pine Grove, Southport, PR9 9AG, England Tel: +44 (0)1704 543830 Fax: +44 (0)1704 544799 Internet: www.isotech.co.uk

More information

Dual laser + type K thermometer INFRARED THERMOMETER

Dual laser + type K thermometer INFRARED THERMOMETER Dual laser + type K thermometer INFRARED THERMOMETER Model : ATE-2509 Your purchase of this INFRARED THERMOMETER marks a step forward for you into the field of precision measurement. Although this METER

More information

Telescopic auto dimension measuring system

Telescopic auto dimension measuring system - 0 - Contents Chapter One: Brief introduction 2 Chapter Two: Safety cautions 3 Chapter Three: Spare parts list and name 4 Chapter Four: User manual 7 I. Distance between 250~1140mm (M3:250~900mm) II.

More information

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) National Optical & Scientific Instrument Inc. 6508 Tri-County Parkway Schertz, Texas 78154 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR SHOP MICROSCOPES MODEL NUMBERS 186 187 188 189 National

More information

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope Richter Optica info@richter-optica.com Instructions for Model: S850 Stereo Zoom Microscope Microscope Head Focus Knob Stage Clips Zoom Knob C-Mount Adapter Eyepiece Focusing Holder Focusing Holder Set

More information

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION Effective: January 2004 Supersedes, dated June 1998 APPLICATION QUALITY FEATURES Descriptive Bulletin 41-078INTL Flexitest Switch Assemblies Type The type FT-19R (standard length) and FT-19RX (extended

More information

ELECTROMAGNETIC-ACOUSTIC TRANSDUCERS FOR IN-SERVICE MANUAL TESTING OF HEATED OBJECTS

ELECTROMAGNETIC-ACOUSTIC TRANSDUCERS FOR IN-SERVICE MANUAL TESTING OF HEATED OBJECTS 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China ELECTROMAGNETIC-ACOUSTIC TRANSDUCERS FOR IN-SERVICE MANUAL TESTING OF HEATED OBJECTS Vladimir T. BOBROV, Andrey A. SAMOKRUTOV,

More information

Infrared Sensors. Operators manual thermometer CSL-SF50 / CSLM-2HSF300

Infrared Sensors. Operators manual thermometer CSL-SF50 / CSLM-2HSF300 Infrared Sensors Operators manual thermometer CSL-SF50 / CSLM-2HSF300 CE-Conformity The product complies with the following standards: EMC: EN 61326-1:2006 (Basic requirements) EN 61326-2-3:2006 Safety:

More information

DIGITAL THERMOMETER WITH TRICOLOR LCD INSTRUCTION MANUAL

DIGITAL THERMOMETER WITH TRICOLOR LCD INSTRUCTION MANUAL Model no 240022 Component No. 692650 DIGITAL THERMOMETER WITH TRICOLOR LCD INSTRUCTION MANUAL THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT.

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection

More information

ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

ph Electrode basics ph Electrodes  Model 19 B /1 =1 m 24 B /1 =1 m s ph electrodes are constructed from a special composition which senses the hydrogen ion concentration. This is typically composed of alkali metal ions. The alkali metal ions of the and the hydrogen ions

More information

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual Coating Thickness Gauge art. nr. 59252 Table of contents 1. Technical specifications...3 2. Getting started...3 3. Gauge manual...6 The price of this product includes the recycling fee of 0,10 PLN Guarantee...11

More information

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER nu-beca NO TOUCH THERMOMETER : Thank you for purchasing the nu-beca No Touch Forehead Thermometer. Please read this instruction manual first so you can use this

More information

Introduction to Blackbody Sources

Introduction to Blackbody Sources Introduction to s This section contains dedicated blackbody sources for low uncertainty calibration of infrared thermometers. A range of portable primary blackbody sources combine high emissivity with

More information

Surveying Instruments. B Series B20 B30 B40. Automatic Levels

Surveying Instruments. B Series B20 B30 B40. Automatic Levels Surveying Instruments B Series B20 B30 B40 Automatic Levels World-Proven Precision and Durability B20 Automatic Level B30 Automatic Level B40 Automatic Level 28x 1.5mm Accuracy 32x 0.7mm Accuracy 24x 2.0mm

More information

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008 Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB41-078 March 2008 FT-19R and FT-19RX FT-19R 3RU with Individual Clear Covers APPLICATION FEATURES The type FT-19R (standard length) and

More information

Magnetic Separators for Recycling

Magnetic Separators for Recycling Magnetic Separators for Recycling Driven by magnetism since 1959 In recent years, Goudsmit Magnetics has significantly extended its set of magnetic systems for the recycling industry. This brochure gives

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion

More information

Jumbo Cross Beam Ionizer

Jumbo Cross Beam Ionizer Jumbo Cross Beam Ionizer Version 1.0 September 30, 2008 Page 1 of 19 Table of Contents Cross Beam Ionizer... 1 Table of Contents... 2 1.0 Packing List... 3 1.1 Packing List for Cross Beam Ionizer... 3

More information

(PT-A6) Visible Light Detector for Security Lighting

(PT-A6) Visible Light Detector for Security Lighting Version: July 4, 2017 (PT-A6) Visible Light Detector for Security Lighting Token Electronics Industry Co., Ltd. Web: www.token.com.tw Email: rfq@token.com.tw Taiwan: No.137, Sec. 1, Zhongxing Rd., Wugu

More information

ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook

ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook Isotech North America 158 Brentwood Drive, Unit 4 Colchester, VT 05446 Phone: 802-863-8050 Fax: 802-863-8125 sales@isotechna.com www.isotechna.com

More information

Dr. Michael Müller. Thermal Management for LED applications

Dr. Michael Müller. Thermal Management for LED applications Thermal Management for LED applications Content Thermal Design Basics thermal management Internal thermal management External thermal management 2 1967 founded with the production of insulation parts for

More information

Heat and Temperature

Heat and Temperature Chapter 4 Heat Heat and Temperature Heat is a form of energy Heat is the energy of random motion of molecules constituting the body. It flows from a hot body to a cold body. Unit of heat is joule (J) and

More information

DIGITAL ABBE REFRACTOMETER INE-WYA-2S OPERATING INSTRUCTION PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

DIGITAL ABBE REFRACTOMETER INE-WYA-2S OPERATING INSTRUCTION PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION DIGITAL ABBE REFRACTOMETER INE-WYA-2S OPERATING INSTRUCTION PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.11.16

More information

(PT-A6) Visible Light Detector for Security Lighting

(PT-A6) Visible Light Detector for Security Lighting Version: July 31, 2017 Electronics Tech. (PT-A6) Visible Light Detector for Security Lighting Web: www.direct-token.com Email: rfq@direct-token.com Direct Electronics Industry Co., Ltd. China: 12F, Zhong

More information

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE 3 0 15 15 E OWNER S MANUAL COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE 5 W 60 W 30 W 45 W Zhumell customers know that there are plenty of ways to experience the world. They also understand

More information

Instruction Manual HI Refractometer for Sodium Chloride Measurements

Instruction Manual HI Refractometer for Sodium Chloride Measurements Instruction Manual HI 96821 Refractometer for Sodium Chloride Measurements www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully

More information

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL 1 1. CONTENTS 2. Nomenclature page 3 3. Care and Maintenance page 4 4. Using your Instrument 4.1 Setting up your Instrument page 5 4.2 Stadia

More information

Superconductivity. Never store liquid nitrogen in a container with a tight fitting lid.

Superconductivity. Never store liquid nitrogen in a container with a tight fitting lid. Superconductivity 1 Introduction In this lab we will do some very simple experiments involving superconductors. You will not have to take much data; much of what you do will be qualitative. However, in

More information

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL HI96821 Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully before using this

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

ME 105 Mechanical Engineering Laboratory Spring Quarter INTRODUCTION TO TRANSIENT CONDUCTION AND CONVECTION

ME 105 Mechanical Engineering Laboratory Spring Quarter INTRODUCTION TO TRANSIENT CONDUCTION AND CONVECTION ME 105 Mechanical Engineering Lab Page 1 ME 105 Mechanical Engineering Laboratory Spring Quarter 2003 2. INTRODUCTION TO TRANSIENT CONDUCTION AND CONVECTION This set of experiments is designed to provide

More information

Second Focal Plane MRAD

Second Focal Plane MRAD RIFLESCO PE 1 6x24 Second Focal Plane MRAD The Vortex Razor HD Gen II 1 6x24 Riflescope At Vortex Optics, the need for high-performance, precision optics is the driving force behind all that we do. We

More information

Infrared Hand-Held Thermometers

Infrared Hand-Held Thermometers Infrared Hand-Held Thermometers measuring monitoring analysing Model: TIR-H... Measuring range from -2 to 5 C to -32 to 9 C Measuring accuracy: ±1% to ± 2% of measured value Option: analogue output, RS

More information

Ultrasonic Thickness Gauge TIME2110 (V )

Ultrasonic Thickness Gauge TIME2110 (V ) Ultrasonic Thickness Gauge TIME2110 (V20140815) Beijing TIME High Technology Ltd. 1 Content 1. GENERAL DESCRIPTION... 1 2. PERFORMANCE PARAMETERS... 4 3. MAIN FUNCTIONS... 4 4. SWITCH BETWEEN METRIC AND

More information

RoHS. Specification CUD8DF1A. Drawn Approval Approval. 서식 Rev: 00

RoHS. Specification CUD8DF1A. Drawn Approval Approval.  서식 Rev: 00 Specification RoHS CUD8DF1A SVC Customer Drawn Approval Approval 1 [ Contents ] 1. Description 2. Outline dimensions 3. Characteristics of CUD8DF1A 4. Characteristic diagrams 5. Binning & Labeling 6. Reel

More information

Noncontact Thermometer

Noncontact Thermometer InfraPro 1 Standard Model 35629-00 InfraPro 2 Enhanced Model 35629-10 Noncontact Thermometer 57511-1 Rev. A 4/00 Specifications Temperature range 35629-00 -32 to 400 C (-25 to 750 F) 35629-10 -32 to 545

More information

Manual Dew point scanner PCE-DPT 1

Manual Dew point scanner PCE-DPT 1 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA Tel: 410-387-7703 Fax: 410-387-7714 info@pce-americas.com www.pce-instruments.com/us www.industrial-needs.com PCE Instruments UK Ltd. Units

More information

Republic of Somaliland. Somaliland National Examination Board. Form Four. Physics Examination. June 2009 TIME 2 HOURS

Republic of Somaliland. Somaliland National Examination Board. Form Four. Physics Examination. June 2009 TIME 2 HOURS Name..... Total Score School... Roll No... Republic of Somaliland Form Four Physics Examination June 2009 TIME 2 HOURS Plus 10 minutes for reading through the paper Total time 2 Hours and 10 Minutes INSTRUCTIONS

More information

15 E OWNER S MANUAL PIRATE SPYGLASS BRING EM NEAR PIRATE SPYGLASS TELESCOPE 5 W 30 W 60 W 45 W

15 E OWNER S MANUAL PIRATE SPYGLASS BRING EM NEAR PIRATE SPYGLASS TELESCOPE 5 W 30 W 60 W 45 W 3 0 15 15 E OWNER S MANUAL PIRATE SPYGLASS BRING EM NEAR PIRATE SPYGLASS TELESCOPE 5 W 60 W 30 W 45 W Zhumell customers know that there are plenty of ways to experience the world. They also understand

More information

63/66/68. Infrared Thermometers. Users Manual

63/66/68. Infrared Thermometers. Users Manual 63/66/68 Infrared Thermometers Users Manual PN 2149032 September 2004 Rev. 3, 6/09 2004-2009 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice.

More information

2. OPERATIONAL CONDITIONS

2. OPERATIONAL CONDITIONS 1. INTRODUCTION This device was designed for modern physics labs of colleges and graduate schools. It demonstrates the influence of a magnetic field on light, known as Zeeman Effect, and reveals the behavior

More information

Specification YGHR411-H

Specification YGHR411-H Specification HR411H Pb Free Drawn SSC Approval Customer Approval [ Contents ] 1. Description 2. Absolute maximum ratings 3. ElectroOptical characteristics 4. Characteristic diagrams 5. Reliability result

More information

ZENITHSTAR 61 APO. Owner s Manual ver

ZENITHSTAR 61 APO. Owner s Manual ver ZENITHSTAR 61 APO Owner s Manual ver. 1.1 2017.07 Contents Specification 3 Telescope Diagram 4 Accessories Map 5 Usage 6 Storage and Cleaning 7 Caution and Safety, Optional Equipment 8 Optional Equipment

More information

Operator s Manual. optris CSlaser. LT/ hs LT/ 2M/ G5. Infrared-thermometer

Operator s Manual. optris CSlaser. LT/ hs LT/ 2M/ G5. Infrared-thermometer Operator s Manual optris CSlaser LT/ hs LT/ 2M/ G5 Infrared-thermometer Optris GmbH Ferdinand-Buisson-Str. 14 13127 Berlin Germany Tel.: +49 30 500 197-0 Fax: +49 30 500 197-10 E-mail: info@optris.de Internet:

More information

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of

More information

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30 eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize

More information

The Vortex Razor HD Gen II-E 1 6x24 Riflescope

The Vortex Razor HD Gen II-E 1 6x24 Riflescope The Vortex Razor HD Gen II-E 1 6x24 Riflescope At Vortex Optics, the need for high-performance, precision optics is the driving force behind all that we do. We carefully built the Razor HD Gen II-E riflescope

More information

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER Users Manual -1- .Introduction

More information

Ultrasonic Thickness Gauge TT130 TIME Group Inc. Beijing TIME High Technology Ltd.

Ultrasonic Thickness Gauge TT130 TIME Group Inc. Beijing TIME High Technology Ltd. Ultrasonic Thickness Gauge TT130 TIME Group Inc. Beijing TIME High Technology Ltd. Content 1. GENERAL DESCRIPTION... 3 1.1 SCOPE OF APPLICATION... 4 1.2 BASIC WORKING PRINCIPLE... 4 1.3 BASIC CONFIGURATION

More information

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a

More information

The Vortex. Dual Use: Shooting Tactical / Hunting US Patent 8,166,696 US Patent 7,937,879. Elevation. Adjustment Dial.

The Vortex. Dual Use: Shooting Tactical / Hunting US Patent 8,166,696 US Patent 7,937,879. Elevation. Adjustment Dial. 1-6 x 24 RIFLESCOPE The Vortex Viper PST 1 6x24 Riflescope At Vortex Optics, the need for high-performance, precision optics is the driving force behind all that we do. We carefully build Viper PST riflescopes

More information

Low Differential Pressure Gage

Low Differential Pressure Gage Low Differential Pressure Gage NEW Manostar Gage Panel installation compact type Low Differential Pressure Gage RoHS compliant Utility model registration No.2027772 Compact and lightweight type Even when

More information

The Vortex Razor HD Gen II 1 6x24 Riflescope

The Vortex Razor HD Gen II 1 6x24 Riflescope The Vortex Razor HD Gen II 1 6x24 Riflescope At Vortex Optics, the need for high-performance, precision optics is the driving force behind all that we do. We carefully built the Razor HD Gen II riflescope

More information

Instruction Manual HI Refractometer for Sucrose in Wine and Grape Products Measurements

Instruction Manual HI Refractometer for Sucrose in Wine and Grape Products Measurements Instruction Manual HI 96811 Refractometer for Sucrose in Wine and Grape Products Measurements www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction

More information

High Accuracy High Speed in Your Process

High Accuracy High Speed in Your Process DX-Series Handheld Precision IR Thermometers EXERGEN C O R P O R A T I O N The Only Certified Accurate NIST Traceable Infrared Temperature Instruments in the World* High Accuracy High Speed in Your Process

More information

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com INSTRUCTION MANUAL Milwaukee Refractometer MA871 Refractometer for Sucrose Measurements 1 Instruction Manual

More information

Amplified Pyranometer SP-212 & 215

Amplified Pyranometer SP-212 & 215 Amplified Pyranometer SP-212 & 215 Amplified Pyranometer Sensor This sensor is calibrated to measure total shortwave radiation. The evaporation of water from soil and the transpiration of water from plant

More information

BALL GRID ARRAY REWORK TRAINING CERTIFICATION TEST (DVD-96C) v.2

BALL GRID ARRAY REWORK TRAINING CERTIFICATION TEST (DVD-96C) v.2 This test consists of twenty multiple-choice questions. All questions are from the video: Ball Grid Array Rework (DVD-96C). Each question has only one most correct answer. Circle the letter corresponding

More information

INFRARED TEMPERATURE SENSORS OPERATION AND SELECTION

INFRARED TEMPERATURE SENSORS OPERATION AND SELECTION INFRARED TEMPERATURE SENSORS OPERATION AND SELECTION By Vern Lappe, Vice President, Technical Services, Ircon, Inc. There are many ways to measure temperature in a process. Sensors, such as thermocouples,

More information

product manual H-4204 Proving Ring Penetrometer

product manual H-4204 Proving Ring Penetrometer 05.09 product manual H-4204 Proving Ring Penetrometer nnmm Handle Proving Ring Extension Rod Coupler Penetration Rod Cone Figure #1 General Information The Proving Ring Penetrometer is a cone type of penetrometer

More information